S02-Hot Work Permit - Lebanon.doc

DOC document 49 KB Posted

Attached to
Z1DA--LOCAL minimum guarantee base Construction MATOC| Lebanon-Altoona Construction MATOC (VA-26-00000908)
Solicitation number
36C24425R0084
Issued by

About this file

The document is a Hot Work Permit safety form from January 2014, designed to manage and control high-risk work activities involving cutting, welding, or soldering. The comprehensive checklist covers critical safety precautions including deactivating sprinkler and smoke detection systems, ensuring clean work areas, removing flammable materials, protecting pedestrian traffic, having fire extinguishing equipment available, and providing a fire watch for 30 minutes after work completion.

The related federal contract opportunity is a Multiple Award Task Order Contract (MATOC) issued by the Department of Veterans Affairs Veterans Health Administration for construction projects at Lebanon and Altoona VAMCs. The solicitation will award up to 10 firm fixed-price contracts with a five-year performance period or until $250 million is expended. The procurement uses a tiered evaluation approach prioritizing Service-Disabled Veteran-Owned Small Businesses (SDVOSB), followed by Veteran-Owned Small Businesses (VOSB), and then Small Businesses (SB). Key dates include a site visit on 9-24-25, Request for Information deadline on 10-7-25, and proposal submissions due on 10-23-25 at 3:00 PM Eastern Time, with a NAICS code of 236220 and a small business size standard of $45 million in annual receipts.

View the file

Other files

File Type Posted
S02-P01-Seed Project - Narrative - Building 1 Entrance Enclosure redacted.pdf PDF
Contractor Pre-Award OSHA Evaluation Form.pdf PDF
S02 EXHIBIT C Past Performance Questionnaire 10.15.25.docx DOCX document
S02-Seed Project - Drawings - Building 1 Entrance Enclosure.pdf PDF
36C24425R0084 0002.pdf PDF
36C24425R0084 0002_1.docx DOCX document
MATOC Sitewalk SignIn 9-24-25.pdf PDF
36C24425R0084 0001_1.docx DOCX document
36C24425R0084 0001.pdf PDF
S02-P01-Seed Project - Narrative - Building 1 Entrance Enclosure redacted.pdf PDF
S02-S02-EXHIBIT D Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx DOCX document
36C24425R0084_2.docx DOCX document
S02-S02-EXHIBIT A - Statement of Prior Experience.docx DOCX document
S02-S02-EXHIBIT B Subcontractor Information and Consent Form 5.29.25.docx DOCX document
S02-P01-Seed Project - Narrative - Building 1 Entrance Enclosure.pdf PDF
S02-Seed Project - Drawings - Building 1 Entrance Enclosure.pdf PDF
S02-S02-EXHIBIT C Past Performance Questionnaire 5.29.25.docx DOCX document
S02-112713-010000-General Requirements -Lebanon.pdf PDF
S02-P11-MCR Altoona - Medical Center Requirements 8.15.25.pdf PDF
S02-P11-013526 Lebanon Safety Requirements Spec.docx DOCX document
S02-Seed Project Task Order Package 7.17.25f.docx DOCX document
S02-Davis Bacon Act WD PA20250093 _01.pdf PDF
36C24425R0084 9.22.25 R1.pdf PDF
36C24425R0084 9.22.25.pdf PDF
36C24425R0084_3.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Safety Manual

Attachment

January 2014

Chapter 12

SAFETY SECTION HOT WORK PERMIT

ISSUED TO: __________________________ BUILDING/ROOM: _______________

TYPE OF WORK PERFORMED: __________________________________________

NECESSARY PRECAUTIONS:(

SPRINKLER SYSTEM DEACTIVATED

SMOKE DETECTOR SYSTEM DEACTIVATED

CUTTING, WELDING, AND SOLDERING EQUIPMENT IN GOOD WORKING CONDITION

FLOORS SWEPT CLEAN OF COMBUSTIBLES

FLAMMABLE LIQUIDS REMOVED FROM WORK AREA

ALL WALL AND FLOOR OPENINGS COVERED

PEDESTRIAN TRAFFIC PROTECTED FROM SPARKS

FIRE EXTINGUISHING EQUIPMENT ON HAND IN CASE OF FIRE

PERSONNEL INSTRUCTED IN THE INITIATION OF FIRE ALARM

FLOORS WALLS AND CEILINGS PROTECTED FROM SPARKS OR OPEN FLAME

PROPER UTILITIES SECURED SUCH AS OXYGEN, LP GAS, NATURAL GAS, ETC.

FIRE WATCH PROVIDED DURING, AND 30 MINUTES AFTER, WELDING/CUTTING

WORK IS STOPPED

PERMIT DENIED:

REASON: ____________________________________________________

PERMIT GRANTED

DATE: ______________

TIME: _________

PERMIT EXPIRES

DATE: ______________

TIME: _________

As the supervisor or operator of the hot work process/equipment for the above, mentioned project, I agree to be responsible for and follow all fire and safety precautions. I have been informed and understand the provisions of this permit.

(Supervisor/Operator Signature) (Safety Section Inspector Signature)

POST-PROCESS INSPECTION:

DATE: _________ TIME: _________ CONDITION: _______________________

A