Drawings General.pdf
PDF 16 MB Posted
- Solicitation number
- 36C24424R0007
About this file
The provided document appears to be a set of drawings related to the federal contract opportunity for the "Renovate 9th Floor Mental Health Unit" solicitation (Solicitation Number: 36C24424R0007) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4. The solicitation is for construction services to renovate the 9th floor mental health unit. It does not contain details on the specific products or services required, response dates, award dates, pricing terms, set-asides, or other salient information. This appears to be a file containing general drawings rather than a performance work statement, statement of objectives, or other key contractual documents.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA OF WORK
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:5
A M
01-I1
COVER - VOLUME 1 RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD, WILKES-BARRE, PA 18711
VAMC PROJECT #: 693-19-106
RENOVATE 9TH FLOOR MENTAL HEALTH
DWG 01 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
SHEET INDEX - VOLUME 1 OF 2RENDERED IMAGEAREA OF WORK
N o rt h
9TH FLOOR
WAREHOUSE
SHEET
NUMBER SHEET NAME
GENERAL
01-I1 COVER - VOLUME 1
01-I3 GENERAL INFORMATION AND ABBREVIATIONS
01-I4 ACCESSIBILITY STANDARDS
01-I5 PROGRAM FOR DESIGN - 9TH FLOOR
01-I6 DEPARTMENTAL PLAN - 9TH FLOOR
17-I7 DEPARTMENTAL PLAN - WAREHOUSE
01-I8 PHASING PLAN
01-I9 CODE DATA
01-I10 LIFE SAFETY PLAN - 9TH FLOOR
17-I11 LIFE SAFETY PLAN - WAREHOUSE
HAZARDOUS MATERIALS
01-H1 ACM PLAN - 9TH FLOOR - WEST
01-H2 ACM PLAN - 9TH FLOOR - CENTER
01-H3 ACM PLAN - 9TH FLOOR - EAST
17-H4 ACM PLAN - WAREHOUSE
STRUCTURAL
01-S1 STRUCTURAL NOTES
01-S2 STRUCTURAL SPECIAL INSPECTIONS SCHEDULE
01-S3 9TH FLOOR SUN ROOF COLUMNS
01-S4 9TH FLOOR COLUMN AND BASE PLATE PARTIAL ENLARGED PLAN
01-S5 SUN ROOM ROOF FRAMING PLAN
01-S6 SUN ROOM ROOF ENLARGED FRAMING PLAN
17-S7 WAREHOUSE ROOF FRAMING PLANS
01-S8 EXTERIOR FRAMING ELEVATIONS & FRAMING SECTIONS
01-S9 CONNECTION DETAILS
01-S10 CONNECTION DETAILS
01-S11 CONNECTION DETAILS
01-S12 CONNECTION DETAILS
01-S13 PANELIZED SECURITY SCREEN
17-S14 WAREHOUSE MECH UNITS
ARCHITECTURAL
01-A1 ARCHITECTURAL ABBREVIATIONS, NOTES & SYMBOLS
01-A2 DEMOLITION PLAN - 9TH FLOOR - OVERALL
01-A3 DEMOLITION PLAN - 9TH FLOOR - WEST
01-A4 DEMOLITION PLAN - 9TH FLOOR - CENTER
01-A5 DEMOLITION PLAN - 9TH FLOOR - EAST
17-A6 DEMOLITION PLAN - WAREHOUSE
01-A7 RCP DEMO PLAN - 8TH FLOOR
01-A8 EXTERIOR DEMOLITION ELEVATIONS
01-A9 EXTERIOR DEMOLITION ELEVATIONS
01-A10 EXTERIOR DEMOLITION SECTIONS
01-A11 FLOOR PLAN - 9TH FLOOR - OVERALL
01-A12 FLOOR PLAN - 9TH FLOOR - WEST
01-A13 FLOOR PLAN - 9TH FLOOR - CENTER
01-A14 FLOOR PLAN - 9TH FLOOR - EAST
17-A15 FLOOR PLAN - WAREHOUSE
01-A16 REFLECTED CEILING PLAN - 8TH FLOOR
01-A17 REFLECTED CEILING PLAN - 9TH FLOOR - OVERALL
01-A18 REFLECTED CEILING PLAN - 9TH FLOOR - WEST
01-A19 REFLECTED CEILING PLAN - 9TH FLOOR - CENTER
01-A20 REFLECTED CEILING PLAN - 9TH FLOOR - EAST
17-A21 REFLECTED CEILING PLAN - WAREHOUSE
01-A22 ROOF PLAN - 9TH FLOOR
17-A23 ROOF PLAN - WAREHOUSE
01-A24 FINISH PLAN - 9TH FLOOR - OVERALL
01-A25 FINISH PLAN - 9TH FLOOR - WEST
01-A26 FINISH PLAN - 9TH FLOOR - CENTER
01-A27 FINISH PLAN - 9TH FLOOR - EAST
17-A28 FINISH PLAN - WAREHOUSE
01-A29 FURNITURE PLAN - WAREHOUSE
01-A30 EXTERIOR ELEVATIONS
01-A31 EXTERIOR ELEVATIONS
17-A32 EXTERIOR ELEVATIONS
01-A33 INTERIOR ELEVATIONS
01-A34 INTERIOR ELEVATIONS
01-A35 INTERIOR FINISH ELEVATIONS
01-A36 BUILDING SECTIONS
01-A37 WALL SECTIONS
01-A38 ENLARGED FLOOR PLANS
01-A39 ENLARGED FLOOR PLANS
01-A40 MILLWORK SECTIONS
01-A41 PLAN DETAILS
01-A42 PLAN DETAILS
SHEET
NUMBER SHEET NAME
01-A43 SECTION DETAILS
01-A44 SECTION DETAILS
01-A45 WALL TYPE SCHEDULE
01-A46 DOOR SCHEDULES & DETAILS
01-A47 WINDOW FRAME TYPES
01-A48 WINDOW DETAILS
01-A49 FINISH SCHEDULE
01-A50 INTERIOR PERSPECTIVES
01-A51 INTERIOR PERSPECTIVES
01-A52 INTERIOR PERSPECTIVES
01-A53 INTERIOR AXONS
FIRE ALARM
01-F1 FIRE ALARM GENERAL NOTES
01-F2 FIRE ALARM PLAN - 9TH FLOOR - WEST
01-F3 FIRE ALARM PLAN - 9TH FLOOR - CENTER
01-F4 FIRE ALARM PLAN - 9TH FLOOR - EAST
17-F5 FIRE ALARM PLAN - WAREHOUSE
FIRE PROTECTION
01-F6 FIRE PROTECTION GENERAL NOTES
01-F7 HAZARD PLAN - 9TH FLOOR - WEST
01-F8 HAZARD PLAN - 9TH FLOOR - CENTER
01-F9 HAZARD PLAN - 9TH FLOOR - EAST
17-F10 HAZARD PLAN - WAREHOUSE
01-F11 FIRE PROTECTION PLAN - 9TH FLOOR - WEST
01-F12 FIRE PROTECTION PLAN - 9TH FLOOR - CENTER
01-F13 FIRE PROTECTION PLAN - 9TH FLOOR - EAST
17-F14 FIRE PROTECTION PLAN - WAREHOUSE
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
ZMiller Image
A. WORK SHALL CONFORM WITH PROJECT SPECIFICATIONS.
B. CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK. QUESTIONS
WILL BE DIRECTED TO VHA COR.
C. CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND THE SAFETY OF CONSTRUCTION PERSONNEL AND VISITORS.
D. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR. REFER
TO SPECIFICATION SECTION 01 33 23.
E. EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE VHA COR, IN WRITING, ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THEIR WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH
INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.
F. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT VHA COR FOR
CLARIFICATIONS, IF REQUIRED.
G. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR DIMENSION IS REPRESENTATIVE
OF, OR THE SAME, FOR SIMILAR CONDITIONS THROUGHOUT.
H. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN, SECTION, &
DETAIL DRAWINGS, ETC), CONTACT VHA CO FOR CLARIFICATION.
I. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, SPECIFICATIONS GOVERN.
CONTACT VHA CO FOR CLARIFICATION.
J. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS SHALL BE REPORTED TO THE VHA
CO, IN WRITING, FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
K. DISCREPANCIES SHALL BE REPORTED TO THE VHA CO IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE CONTRACTING OFFICER'S WRITTEN DIRECTION AND APPROVAL.
ALSO, CONTRACTOR SHALL REPAIR AND/OR REPLACE UNAUTHORIZED WORK, AS INDICATED BY THE VHA COR, AT NO ADDITIONAL COST TO THE VHA.
L. ALL DISSIMILAR METAL MATERIALS SHALL BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION MATERIAL
IN ACCORDANCE WITH SPECIFICATIONS.
M. ALL EXTERIOR EXPOSED STEEL SHALL BE PAINTED PER SPECIFICATION SECTION 09 91 00.
N. CONTRACTOR SHALL VERIFY THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES AND THEIR SERVICE
CONNECTIONS WITH THE PROPER UTILITY COMPANY, COORDINATE ANY ISSUES WITH VHA COR.
O. CONTRACTOR SHALL COORDINATE SIZE, LOCATIONS AND NUMBER OF ROOF OPENINGS AND ROOF ACCESSORIES WITH OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL
AND ELECTRICAL DRAWINGS FOR REFERENCE AND SPECIFICATIONS FOR REQUIREMENTS.
P. LOCATIONS AND SIZES OF CONCRETE MECHANICAL AND ELECTRICAL EQUIPMENT PADS SHALL BE COORDINATED WITH THE SELECTED EQUIPMENT MANUFACTURER AND/OR SUPPLIER. LOCATIONS ARE TO BE
APPROVED BY THE VHA COR PRIOR TO PROCEEDING WITH THE WORK.
Q. AT TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING. BOTTOM TO BE LOCATED AT 4" AFF VERIFY LENGTHS AND LOCATIONS WITH ELECTRICAL DRAWINGS. REFER TO SPECIFICATION SECTION 06 10 00.
R. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
S. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD AS REQUIRED FOR THE MOUNTING OF ALL TOILET ACCESSORIES, MILLWORK, CASEWORK, AV EQUIPMENT, MEP ITEMS AND RADIOLOGY EQUIPMENT, ETC. REFER
TO SPECIFICATIONS.
T. PROPRIETARY PRODUCTS SHOWN ON THE DRAWINGS SHALL MEET SPECIFICATION REQUIREMENTS.
U. REFER TO SPECIFICATION SECTION 01 45 29 FOR ALL REQUIRED TESTING AND INSPECTIONS.
A
ROOM NAME
C
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
DETAIL CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION, DETAIL, OR ELEVATION
SYMBOL IDENTIFIERS
DETAIL NAME
LETTER OR NUMBER DESIGNATOR
DRAWING SEQUENCE NUMBER
INDICATES WHERE TITLE IS LOCATED
ONE OR TWO CHARACTER
DISCIPLINE DESIGNATOR (MAY
NOT BE PRESENT IF CALLOUT
AND TITLE ARE ON DRAWINGS
WITHIN THE SAME DISCIPLINE)
AE101
DOOR NUMBER TAG
WALL TYPE TAG
WINDOW TYPE TAG
CENTER LINE
COLUMN BUBBLE
ROOM TAG
MATCH LINE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
DETAIL NUMBER ON SHEET
SHEET NUMBER
NEW LINE TYPE
EXISTING LINE TYPE
DEMO LINE TYPE
DEMO HATCH TYPE
View Name
1/8" = 1'-0"
AE101
AE101
A
A101
SYMBOLS LEGEND
AE101
1 HOUR FIRE NEW
2 HOUR FIRE NEW
1 HOUR FIRE EXISTING
2 HOUR FIRE EXISTING
0 HOUR SMOKE PARTITION NEW
0.5 HOUR SMOKE NEW
1 HOUR FIRE/SMOKE NEW
2 HOUR FIRE/SMOKE NEW
SMOKE EXISTING
0.5 HOUR SMOKE EXISTING
1 HOUR FIRE/SMOKE EXISTING
2 HOUR FIRE/SMOKE EXISTING
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:5
A M
01-I3
GENERAL INFORMATION AND
ABBREVIATIONS
RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 02 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
GENERAL NOTESGENERAL ABBREVIATIONS
A
ABA ARCHITECTURAL BARRIERS ACT
AC AIR CONDITIONING
AD AREA DRAIN
ADJ ADJUSTABLE / ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ATTEN ATTENUATION
AUTO AUTOMATIC
AV AUDIO / VISUAL
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BM BENCH MARK / BEAM
BO BOTTOM OF
BOC BACK OF CURB
BOT BOTTOM
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BVL BEVELED
C
CAP CAPACITY
CB CATCH BASIN
CCTV CLOSED CIRCUIT TV
CF CUBIC FEET
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CIP CAST-IN-PLACE
CL CENTER LINE
CLG CEILING
CLR CLEAR / CLEARANCE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECTION / CONNECT
CONST CONSTRUCT / CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR / CORRUGATED
CP CONCRETE PIPE
CS COUNTERSINK
CU CUBIC
CW COLD WATER
D
DBL DOUBLE
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
E
E EAST
EA EACH
ABBREVIATIONS LISTED BELOW ARE GENERAL ABBREVIATIONS ACROSS ALL DISCIPLINES. DISCIPLINE SPECIFIC ABBREVIATIONS MAY SUPERSEDE GENERAL ABBREVIATIONS. REFER TO DISCIPLINE SPECIFIC ABBREVIATIONS SHEETS.
EF EXHAUST FAN
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
ETR EXISTING TO REMAIN
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FB FACE BRICK
FBO FURNISHED BY OWNER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FF FINISH FLOOR
FF&E FIXTURES, FURNITURE & EQUIPMENT
FFE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RATED
FRMG FRAMING
FS FLOOR SINK
FT FOOT/ FEET
FTG FOOTING
FUT FUTURE
G
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
GPM GALLON PER MINUTE
H
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HORIZ HORIZONTAL
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING / VENTILATING / AIR
CONDITIONING
HW HOT WATER
HYD HYDRANT
I
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE (D), (ING)
INFO INFORMATION
INST INSTALL / INSTALLATION
INSUL INSULATE / INSULATION
INT INTERIOR
INV INVERT
J
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
K
KIT KITCHEN
KO KNOCKOUT
L
L LONG / LENGTH
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT (FEET)
LH LEFT HAND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LRG LARGE
LT LIGHT
LTG LIGHTING
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
M
MAS MASONRY
MAX MAXIMUM
MBR MEMBER
MECH MECHANICAL
MED MEDIUM
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MOD MODULAR
MTD MOUNTED
MTG MOUNTING
MTL METAL
N
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NSF NET SQUARE FEET
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD / OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
P
PA PUBLIC ADDRESS
PB PUSH BUTTON
PC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE (D)
PERM PERMANENT
PERP PERPENDICULAR
PL PLATE / PROPERTY LINE
PLUMB PLUMBING
PNL PANEL
PR PAIR
PREFAB PREFABRICATE (D)
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARE (D)
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
PVG PAVING
Q
QTY QUANTITY
R
R RISER / RADIUS
RA RETURN AIR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REINF REINFORCE (D), (ING)
REQD REQUIRED
REV REVISED/ REVISION
RH RIGHT HAND
RM ROOM
ROW RIGHT OF WAY
RR RESTROOM
RTU ROOF TOP UNIT
S
S SOUTH
SAN SANITARY SEWER
SCH SCHEDULE
SCRN SCREEN
SECT SECTION
SF SQUARE FOOT (SQFT)
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SPKLR SPRINKLE
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD (SQ YD)
SYM SYMMETRICAL / SYMBOL
SYS SYSTEM
T
TEL TELEPHONE
TEMP TEMPORARY / TEMPERED
THK THICK (NESS)
THRU THROUGH
TO TOP OF
TOC TOP OF CURB / CONCRETE
TOD TOP OF DECK
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOR TOP OF ROOF
TOS TOP OF STEEL
TOW TOP OF WALL
TRANSF TRANSFORMER
TV TELEVISION
TYP TYPICAL
U
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V
VERT VERTICAL
VEST VESTIBULE
VHA VETERANS HEALTH ADMINISTRATION
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
W
W WEST, WIDTH, WIDE
W/ WITH
W/IN WITHIN
W/O WITHOUT
WC WATER CLOSET
WH WALL HYDRANT / WATER HEATER
WT WEIGHT
X, Y, Z, MISC
& AND
@ AT
YD YARD
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
CLEAR
FLOOR
SPACE
GRAB BAR
NOTE: PARTITION DOOR IS
TO BE LOCATED OPPOSITE
OF WC LOCATION
5' - 6" CLEAR
1'-4" MIN
1'-6" MAX
6'
C
LE
A R
6" TYP
MIN
1' - 0"
MIN
1' - 6"
PULL SIDE
PUSH SIDE
MIN
2' - 0"
MIN
2' - 0"
PULL SIDE
PUSH SIDE M
IN
4'
M
IN
4'
1' - 10"
MIN
3' - 0"
PULL SIDE
PUSH SIDE M
IN
4'
M
IN
5'
MIN
1' - 10"
MIN
3' - 6"
PULL SIDE
PUSH SIDE
M
IN
4'
M
IN
4'
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
APPROACH
APPROACH
5'
M
IN
4'
M
IN
FIRE EXTINGUISHER
CABINET
IN
S
T A
LL
P
E R
N
F P
A
FIRE EXTINGUISHER
& STANDARD BRACKET
IN
S
T A
LL
P
E R
N
F P
A
1 1/2" O.D. (SS OR CHROME)
GRAB BAR SUPPORTS
250 LBS FORCE (TYP.)
CLEAR FLOOR
4' - 0" MIN
5' - 0" MIN BARIATRIC
4' - 0"
C
LE
A R
F
LO
O R
3'
M
IN
4'
M
IN
B A
R
IA
T R
IC
3'
S E
A T
W A
LL
C O
N T
R O
L W
A
LL
BACK WALL
FOLDING SEAT
MAX
2 1/2"
16" MAX
15" MIN
M A
X
1/ 2"
M A
X
M
IN
1' - 6"
23" MAX
22" MIN
M A
X
1'
CLEAR
FLOOR
SPACE
9" M
IN
2'
M
IN
2'
0"
M A
X
2' - 6" MIN
4'
M
IN
2'
' M
A X
1'
M
IN
PLAN
SECTION
TOE CLEARANCE &
KNEE CLEARANCE
MEASURED TO
THE HIGHER OF
COUNTER OR SINK
11" MIN6" MAX
8" MIN
LIGHT SWITCH
M A
X
4'
MAX
1' - 0"
2"
THERMOSTAT
M
IN
1'
RECEPTACLE
SANITARY
NAPKIN
DISPOSAL
TOILET PAPER
DISPENSER
1'
M
IN
SOAP DISPENSER
( 4" MAX PROJ)
MIRROR
SANITARY
NAPKIN
DISPENSER
INTEGRAL WASTE
DISPOSAL WHERE
APPLICABLE
( 4" MAX PROJECTION)
TOWEL
DISPENSER
PAPER TOWEL
DISPENSER
(4" MAX PROJECTION)
PASS-THRU
PAPER TOWEL DISPENSER
(4" MAX PROJECTION)
R E
F
LE
C T
IV
E
S U
R F
A C
E
3'
M A
X T
O B
O
4'
M A
X
4'
M A
X
4'
R E
F
LE
C T
IV
E
S U
R F
A C
E
6'
M
IN
T O
T O
P O
F
GRAB BAR SUPPORTS
250 LBS FORCE, TYP
B O
O P
E N
IN
G
1'
M
IN
WATER CLOSET FLUSH
HANDLE SHALL BE LOCATED
ON THE TRANSFER SIDE OF
THE STOOL
MIN
2' - 0"
1' - 6" MAX
1' - 4" MIN
DISPENSER
T O
T O
P O
F B
A R
2'
T O
MIN
1' - 0"
ELEVATION
GRAB BAR SUPPORTS
250 LBS FORCE (TYP)
D
IS
P E
N S
E R
O U
T
LE
T
4' -0
M
A
XDISPENSER
1/
2" M
IN
O
U T
LE
T
1'
M
IN
D
IS
P E
N S
E R
T /O
S E
A T
T
O
4' - 6" MIN
T O
T O
P O
F B
A R
2"
T O
MAX
1' - 0"
7" TO 9"
M
IN
A. ALL DIMENSIONS ARE MEASURED FROM THE FINISH FLOOR AND THE FINISH WALL, UNLESS NOTED OTHERWISE. ACCESSIBILITY GUIDELINES ARE BASED ON “PG-18-13 VA BARRIER FREE DESIGN
STANDARD” AND THE “ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS).”
B. ACCESSIBLE UNOBSTRUCTED REACH RANGES:
1. FORWARD REACH = 15" MIN TO 48" MAX
2. SIDE REACH = 15" MIN TO 48" MAX
C. DOOR HARDWARE (TO CENTER OF HARDWARE):
STANDARD MOUNTING HEIGHTS:
1. PUSH PLATES = 42"
2. PULL HANDLES = 42"
3. KNOBS / LEVERS = 40"
4. PANIC DEVICE = 42" CL OF BAR
5. KICKPLATES:
a. WIDTH = DOOR WIDTH MINUS 2"
b. CENTER HEIGHT = 16" FROM BO DOOR
6. THRESHOLDS:
a. STANDARD = 1/2" MAX
b. EXTERIOR SLIDING DOORS = 3/4" MAX
D. COUNTERTOPS (TO SINK RIM / COUNTERTOP):
1. ACCESSIBLE = 28" MIN TO 34" MAX
E. WATER CLOSETS (TO TOP OF SEAT):
1. STANDARD = 14" TO 15"
2. ACCESSIBLE (TO TOP OF SEAT) = 17" TO 19"
3. ACCESSIBLE FLUSH CONTROLS = 44" MAX
F. LAVATORIES (TO SINK RIM / COUNTERTOP):
1. STANDARD = 36" MAX
2. ACCESSIBLE = 34" MAX (29" MIN CLEAR KNEE SPACE)
G. MIRRORS:
1. TO B/O REFLECTIVE SURFACE:
a. STANDARD = VARIES
b. ACCESSIBLE = 40" MAX
2. TO T/O REFLECTIVE SURFACE:
a. STANDARD = VARIES
b. ACCESSIBLE = 74" MIN
H. GRAB BARS - ACCESSIBLE (TO TOP OF BAR):
1. WATER CLOSETS = 33" MIN TO 36" MAX
2. SHOWERS = 33" MIN TO 36" MAX (FROM BO SHOWER)
3. BATHTUBS:
a. TOP BAR = 33" MIN TO 36" MAX
b. BOTTOM BAR = 9" ABOVE TOP OF TUB
I. SHOWER HEADS (FROM FLOOR TO HEAD):
1. STANDARD = 72" TO 84"
2. ACCESSIBLE = SPRAY UNIT WITH HOSE 60" LONG MIN
3. ACCESSIBLE FIXED SHOWER HEAD = 48" AFF
J. SHOWER CONTROLS (TO CONTROL AREA):
1. STANDARD = 48" MAX (TO TOP)
2. ACCESSIBLE = 38" MIN TO 48" MAX
K. TOILET PAPER DISPENSER (TO CL OF OUTLET):
1. STANDARD = 24"
2. ACCESSIBLE = 15" MIN TO 48" MAX
L. WALL MOUNTED SOAP DISPENSER (TO CL OF PUSH BUTTON):
1. STANDARD = 40"
2. ACCESSIBLE = VARIES (REFER TO OBSTRUCTED AND UNOBSTRUCTED REACH RANGES)
3. ACCESSIBLE SIDE REACH = 46" MAX ABOVE SINK IN COUNTER
M. PAPER TOWEL DISPENSER / WASTE RECEPTACLE (TO TOWEL SLOT):
1. STANDARD = 40" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
N. SANITARY NAPKIN DISPENSER (TO CL OF COIN SLOT):
1. STANDARD = 40" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
O. SANITARY NAPKIN DISPOSAL (TO TOP OF UNIT):
1. STANDARD = 28" MAX
2. ACCESSIBLE = 19" MIN TO 24" MAX (TO OPENING).
P. TOILET SEAT COVER DISPENSERS (TO OPENING):
1. STANDARD = 40" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
Q. SHELVES: ACCESSIBLE = 48" MAX
R. COAT HOOKS:
1. STANDARD = 68"
2. ACCESSIBLE = 48" MAX
S. CHALKBOARDS, TACKBOARDS & MARKERBOARDS:
1. STANDARD = 32" TO 39" (TO BO BOARD OR CHALK TRAY)
2. STANDARD = 80" (RECOMMENDED, TO TOP OF BOARD)
T. THERMOSTATS & CONTROL DEVICES (TO TOP):
1. ACCESSIBLE FORWARD REACH = 48" MAX
2. ACCESSIBLE SIDE REACH = 48" MAX
U. LIGHT SWITCHES & CARD READERS (TO CL):
1. LOCATE 6" FROM DOOR JAMB
2. ACCESSIBLE = 48" MAX
V. CONVENIENCE RECEPTACLES / ELECTRICAL / TELEPHONE / DATA (TO CL):
1. STANDARD = 18"
2. ACCESSIBLE = 15" MIN
W. EXIT LIGHTS - WALL MOUNTED:
1. 2" BELOW CEILING
2. 2" MIN ABOVE DOOR FRAME EQUAL SPACE FROM CEILING TO TOP OF FRAME
X. FIRE EXTINGUISHERS (TO TOP UNLESS NOTED OTHERWISE):
1. GROSS WT 40 LBS OR LESS = 60" MAX
2. GROSS WT MORE THAN 40 LBS = 42" MAX
3. ACCESSIBLE = 40" MAX (TO BO CABINET)
Y. FIRE ALARM PULL STATION (TO LEVER):
1. STANDARD = 48" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX
3. ACCESSIBLE SIDE REACH = 48" MAX
Z. SMOKE AND / OR HEAT DETECTORS:
1. STANDARD = CEILING HEIGHT
AA. HORN / SPEAKER / VISUAL SIGNALS:
1. STANDARD = 80" AFF OR 6" BELOW CEILING - WHICHEVER IS LOWER
BB. ROOM SIGNAGE (TO CL):
1. STANDARD = 60" HIGH AFF & WITHIN 18" OF LATCH SIDE OF DOOR
GENERAL NOTES
MIN
8"
M
IN9"
M
IN
2'
MIN
11"
6" MAX
MAX
1' - 5"
M
IN9"
ELEVATION (TC) ELEVATION (KC)PLAN (TC) PLAN (KC)
M
IN
2'
25" MAX
M
IN
2'
17" MIN - 25" MAX
CFGSCFGS
KC
TC
ACCESSIBLE
EWC
STANDARD
EWC
ELEVATION (FRONT)
SPOUT OUTLET HGTS AFF
3'
M A
X
(3 8"
M
IN
T O
3"
M A
X
3'
B O
D
5" MAX
MIN
1' - 3"
ELEVATION (SIDE)
SPOUT OUTLET HGTS AFF
PLAN
CFGS
CFGS, TC, & KC
CENTERED ON
ACCESSIBLE EWC
4"
MAX HORIZ
PROTRUDING
OBJECT IN
CIRCULATION
ROUTE BETWEEN
27" & 80" AFF
ALCOVE PER FLOOR PLANS
STANDARD EWC
ACCESSIBLE EWC
SPOUT OUTLET REQUIREMENTS:
1. SPOUT SHALL PROVIDE A FLOW
OF WATER 4" HIGH, MIN
2. ANGLE OF WATER STREAM
SHALL BE MEASURED
HORIZONTALLY RELATIVE TO
THE FRONT FACE OF THE UNIT.
3. SPOUTS < 3" FROM FRONT FACE
= WATER STREAM 30° MAX
4. SPOUTS > 3" AND 5" MAX FROM
FRONT FACE = WATER STREAM
15° MAX
1'
KC
TCTC
KC
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:5
A M
01-I4
ACCESSIBILITY STANDARDS RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 03 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
1/2" = 1'-0"
ACCESSIBLE CLEAR FLOOR SPACE
B1 1/2" = 1'-0"
TYP. DOOR JAMB & DOOR MANEUVERING CLEARANCES
B4
1/2" = 1'-0"
FIRE EXTINGUISHER
F61/2" = 1'-0"
SHOWER CLEARANCES
F1 1/2" = 1'-0"
SWITCH @ DOOR
F3
1/2" = 1'-0"
TOILET ACCESSORIES
E4
1/2" = 1'-0"
TYPICAL FIXTURE MOUNTING HEIGHTS
C3
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
1/2" = 1'-0"
TOE CLEARANCE (TC) & KNEE CLEARANCE (KC)
E1
1/2" = 1'-0"
ELECTRIC WATER COOLER (EWC)
D7
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:0
A M
01-I5
PROGRAM FOR DESIGN - 9TH
FLOOR
RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 04 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
UP
A B C D E F G H J K L M N O P Q R S T U V
C9-02
HAC
C9-04A
TOILET
C9-04
MEN'SST-2
STAIRC9-09
ELEC
C9-11
QUIET ROOM
C9-C01
CORRIDOR
C9-13
SOILED UTILITY
C9-15A
TOILET
C9-15
MEN'S BARIATRIC
C9-17
GROUP THERAPY
C9-18
MEN'S
C9-18A
TOILET
C9-20A
TOILET
C9-20
MEN'S
C9-24
MEN'S
C9-25A
TOILET
C9-24A
TOILET
C9-25
ANTE ROOM
C9-39
HEAD NURSE
OFFICEC9-43
WOMEN'S
C9-27
NURSE'S STATION
C9-49A
TOILET
C9-49
WOMEN'S BARIATRIC
C9-48
LAUNDRYC9-62
ELEC
C9-66
GERIATRIC
C9-68A
TOILET
C9-66A
TOILETC9-68
BARIATRIC
GERIATRIC
C9-70
CLEAN UTILITY
C9-72
DAY/TV
C9-71
GROUP THERAPY
C9-67
BARIATRIC
GERIATRIC
C9-67A
TOILET
C9-64
NURSE'S STATION
C9-52
SALLY PORT
C9-50
MEETING
C9-45
PATIENT STORAGE
C9-44
WOMEN'S
C9-44A
TOILET
C9-41A
TOILET
C9-41
WOMEN'S
C9-55
MECHANICAL
C9-60
CONFERENCE
C9-54
ELEVATOR LOBBY
C9-61
WORKSTATIONS
C9-43A
TOILET
C9-42
STAFF TOILET
C9-53
ELEC
C9-58
ELECTRICAL
C9-32
MECHANICAL
C9-31
TELECOM ROOM
C9-28
SALLY PORT
C9-33
STAFF
TOILET
C9-35
NURSE'S LOUNGE
C9-36
MECH
C9-34A
ELEC
C9-34
ELEC
C9-30
ELEVATOR LOBBY
C9-23
ELEVATOR
LOBBY
C9-21
SALLY PORT
C9-22
SERVING KITCHEN
C9-19
ELEC
C9-14
MEN'S
C9-14A
TOILET
C9-12A
TOILET
C9-12
MEN'S
C9-08
MEN'S BARIATRIC
C9-08A
TOILET
C9-07
OFFICE
C9-05
TOILET
C9-03
GROUP
COUNSELING ROOM
C9-06
MECHANICAL
C9-06A
ELEC
C9-01
EAST SUNROOM
C9-63
ELEC
C9-51
HAC
C9-38
EXAM/ INTAKE
C9-26
LOBBY
C9-65
MED
C9-69
OFFICE
C9-46
LINEN
Department Legend
ADMIN
BARIATRIC
BLDG SERVICES
CIRCULATION
COMMON SPACE
GERIATRIC
MEN'S PATIENT
PATIENT CARE
WOMEN'S PATIENT
C9-35A
LOCKERS
C9-29
INTERVIEW
C9-40
MED
C9-27A
NURSE'S
WORKROOM
C9-37
TEAMING/
COUNSELING
C9-56
CLEAN STORAGE
C9-10
LAUNDRY
ROOF BELOW
ROOF BELOW
ROOF BELOW
C9-C09
CORRIDOR
C9-57
HAC
C9-47
OFFICE/ GROUP
ROOM
C9-47A
STORAGE
C9-C05
CORRIDOR
C9-25B
SECLUSION ROOM
C9-C03
CORRIDOR
C9-16
DINING/ ACTIVITIES
C9-C04
CORRIDOR
C9-00
COURTYARDC9-C08
CORRIDOR
C9-59
PREFUNCTION/
COLLABORATION
C9-72A
GERIATRIC DINING
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:0
A M
01-I6
DEPARTMENTAL PLAN - 9TH FLOOR RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 05 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
3/32" = 1'-0"
9TH FLOOR DEPARTMENTAL PLAN
E1
ADMIN
C9-05 TOILET 46 SF
C9-07 OFFICE 100 SF
C9-13 SOILED UTILITY 43 SF
C9-22 SERVING KITCHEN 171 SF
C9-27 NURSE'S STATION 271 SF
C9-27A NURSE'S WORKROOM 230 SF
C9-33 STAFF TOILET 76 SF
C9-35 NURSE'S LOUNGE 404 SF
C9-35A LOCKERS 99 SF
C9-35B CLOSET 13 SF
C9-39 HEAD NURSE OFFICE 137 SF
C9-40 MED 144 SF
C9-42 STAFF TOILET 48 SF
C9-46 LINEN 59 SF
C9-48 LAUNDRY 30 SF
C9-59 PREFUNCTION/
COLLABORATION
168 SF
C9-60 CONFERENCE 196 SF
C9-61 WORKSTATIONS 279 SF
C9-64 NURSE'S STATION 268 SF
C9-65 MED 86 SF
C9-69 OFFICE 129 SF
C9-70 CLEAN UTILITY 97 SF
3091 SF
BARIATRIC
C9-08 MEN'S BARIATRIC 237 SF
C9-08A TOILET 65 SF
C9-15 MEN'S BARIATRIC 192 SF
C9-15A TOILET 79 SF
C9-49 WOMEN'S BARIATRIC 187 SF
C9-49A TOILET 77 SF
837 SF
BLDG SERVICES
C9-02 HAC 54 SF
C9-06 MECHANICAL 615 SF
C9-06A ELEC 45 SF
C9-09 ELEC 41 SF
C9-19 ELEC 30 SF
C9-31 TELECOM ROOM 170 SF
C9-32 MECHANICAL 139 SF
C9-34 ELEC 32 SF
C9-34A ELEC 33 SF
C9-36 MECH 114 SF
C9-45 PATIENT STORAGE 34 SF
C9-51 HAC 37 SF
C9-53 ELEC 41 SF
C9-55 MECHANICAL 547 SF
C9-56 CLEAN STORAGE 128 SF
C9-57 HAC 55 SF
C9-58 ELECTRICAL 78 SF
C9-62 ELEC 40 SF
C9-63 ELEC 15 SF
2250 SF
CIRCULATION
C9-21 SALLY PORT 111 SF
C9-23 ELEVATOR LOBBY 191 SF
C9-26 LOBBY 641 SF
C9-28 SALLY PORT 83 SF
C9-30 ELEVATOR LOBBY 430 SF
C9-52 SALLY PORT 106 SF
C9-54 ELEVATOR LOBBY 413 SF
C9-C01 CORRIDOR 1170 SF
C9-C02 CORRIDOR 107 SF
C9-C03 CORRIDOR 230 SF
C9-C04 CORRIDOR 106 SF
C9-C05 CORRIDOR 77 SF
C9-C06 CORRIDOR 764 SF
C9-C07 CORRIDOR 80 SF
C9-C08 CORRIDOR 220 SF
C9-C09 CORRIDOR 225 SF
4953 SF
COMMON SPACE
C9-00 COURTYARD 848 SF
C9-01 EAST SUNROOM 800 SF
C9-10 LAUNDRY 73 SF
C9-11 QUIET ROOM 147 SF
C9-16 DINING/ ACTIVITIES 493 SF
C9-50 MEETING 133 SF
C9-72 DAY/TV 321 SF
C9-72A GERIATRIC DINING 225 SF
3039 SF
GERIATRIC
C9-66 GERIATRIC 213 SF
C9-66A TOILET 56 SF
C9-67 BARIATRIC GERIATRIC 193 SF
C9-67A TOILET 80 SF
C9-68 BARIATRIC GERIATRIC 163 SF
C9-68A TOILET 74 SF
779 SF
MEN'S PATIENT
C9-04 MEN'S 225 SF
C9-04A TOILET 50 SF
C9-12 MEN'S 232 SF
C9-12A TOILET 56 SF
C9-14 MEN'S 230 SF
C9-14A TOILET 55 SF
C9-18 MEN'S 222 SF
C9-18A TOILET 53 SF
C9-20 MEN'S 227 SF
C9-20A TOILET 54 SF
C9-24 MEN'S 220 SF
C9-24A TOILET 69 SF
1692 SF
PATIENT CARE
C9-03 GROUP COUNSELING
ROOM
163 SF
C9-17 GROUP THERAPY 238 SF
C9-25 ANTE ROOM 111 SF
C9-25A TOILET 48 SF
C9-25B SECLUSION ROOM 108 SF
C9-29 INTERVIEW 144 SF
C9-37 TEAMING/ COUNSELING 158 SF
C9-38 EXAM/ INTAKE 136 SF
C9-47 OFFICE/ GROUP ROOM 182 SF
C9-47A STORAGE 52 SF
C9-71 GROUP THERAPY 151 SF
1492 SF
WOMEN'S PATIENT
C9-41 WOMEN'S 254 SF
C9-41A TOILET 54 SF
C9-43 WOMEN'S 213 SF
C9-43A TOILET 69 SF
C9-44 WOMEN'S 210 SF
C9-44A TOILET 57 SF
856 SF
TOTAL NSF*: 18989 SF
* - TOTAL DOES NOT INCLUDE VERTICAL CIRCULATION SPACES OR CHASES
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
DN
L1-110
OFFICE
L1-109
OFFICE
L1-108
OFFICE
L1-107
OFFICE
L1-105
TOILET
L1-104
COPY/LOCKERS
L1-103
OPEN OFFICE
L1-102
SECRETARY
L1-111
CONFERENCE
L1-112
MECH
L1-100
STORAGE
L1-100H
OFFICE
L1-100G
TOILET
Department Legend
ADMIN
BLDG SERVICES
OFFICE
OPEN OFFICE
STORAGE
L1-100A
ELEC
W X Y Z
L1-102A
CLOSET
L1-100F
LOCKERS
L1-100E
TELECOM ROOM
L1-106
TOILET
L1-101
STORAGE
P la n N o rt h T ru e N o rt h
BASEMENT
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:1
A M
17-I7
DEPARTMENTAL PLAN -
WAREHOUSE
RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 06 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
3/16" = 1'-0"
WAREHOUSE DEPARTMENTAL PLAN
F4
AREA SCHEDULE - WAREHOUSE (NET)
NUMBER NAME AREA
L1-001 OXYGEN STORAGE 311 SF
311 SF
ADMIN
L1-100F LOCKERS 67 SF
L1-100G TOILET 50 SF
L1-101 STORAGE 27 SF
L1-102 SECRETARY 102 SF
L1-102A CLOSET 14 SF
L1-104 COPY/LOCKERS 117 SF
L1-105 TOILET 66 SF
L1-106 TOILET 59 SF
L1-111 CONFERENCE 296 SF
799 SF
BLDG SERVICES
L1-100A ELEC 42 SF
L1-100E TELECOM ROOM 100 SF
L1-112 MECH 73 SF
215 SF
OFFICE
L1-100H OFFICE 117 SF
L1-107 OFFICE 97 SF
L1-108 OFFICE 95 SF
L1-109 OFFICE 97 SF
L1-110 OFFICE 102 SF
507 SF
OPEN OFFICE
L1-103 OPEN OFFICE 1625 SF
1625 SF
STORAGE
L1-100 STORAGE 950 SF
L1-100J LOADING DOCK 150 SF
1100 SF
TOTAL NSF: 4558 SF
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
T
T
T
T
T T
T
T
T
T
DN
UP
UP
UP
TO ACHIEVE THE TOTAL PROJECT BUILD OUT, THE DESIGN TEAM HAS
SUGGESTED A PHASING APPROACH FOR KEY PROJECT COMPONENTS THAT
WILL INVOLVE AS FEW MOVES AS POSSIBLE TO LIMIT THE CONFLICT TO THE
OPERATION OF THE WARD DUE TO CONSTRUCTION OF THE PLANS. THIS
PHASING SEQUENCE DOES NOT REQUIRE TEMPORARY SPACE TO BE
ACQUIRED TO HOUSE ANY OF THE COMPONENTS TO COMPLETE THE
PROJECT.
PHASE 1A IS TO DEMOLISH THE INTERIOR WALLS OF WAREHOUSE AND BUILT
OUT THE TENANT SPACE PER THE ENCLOSED PLAN.
PHASE 1 WILL BUILD OUT THE WAREHOUSE AND RELOCATE THE OFFICES ON
THE EAST WING OF THE NINTH FLOOR INTO THE WAREHOUSE
PHASES 2 AND 2A WILL DEMOLISH THE EAST AREA OF THE 9TH FLOOR AND
REBUILD IT TO THE PROPOSED PLAN TO INCLUDE THE NEW NURSES STATION
AND SALLY PORT NEAR THE EAST ELEVATOR CORE, WHILE THE EXISTING
WEST WING STAYS IN OPERATION. PHASE 2A WILL REQUIRE THE REMOVAL OF
6 ROOMS FROM THE CURRENT WARD.
PHASE 3 WILL RELOCATE THE PATIENTS TO THE EAST WING OF THE 9TH FLOOR
AND THEN DEMO AND REBUILD THE WEST END OF THE 9TH FLOOR PER THE
PROPOSED PLAN TO COMPLETE THE PROJECT.
PROJECT PHASING
ROOF BELOW
ROOF BELOW
PHASE 2
EXISTING WARD
TO REMAIN
ROOF BELOW ROOF BELOW
PHASE 2PHASE 2A
EXISTING WARD
TO REMAIN
ROOF BELOWROOF BELOW
PHASE 2A AND 2B
TO BE OPERATIONALPHASE 3
PHASING DIAGRAMS LEGEND
PHASE 2A - EAST WING OF 9TH FLOOR
PHASE 1 - WAREHOUSE REMODEL
PHASE 2B - EAST WING OF 9TH FLOOR - LOBBY
EXISTING - WARD TO REMAIN OPERATIONAL
PHASE 3 - WEST WING OF 9TH FLOOR
EXISTING WARD ROOMS IMPACTED BY PHASE 2A AND 2B
ONE ROOM IMPACTED
SIX TOTAL ROOMS IMPACTED
P la n N o rt h T ru e N o rt h
BLDG 01
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:2
A M
01-I8
PHASING PLAN RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 07 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
ROOMS IMPACTED BY PHASE 2
ROOMS IMPACTED BY PHASES 2 AND 2A
1/16" = 1'-0"
PHASE 1 - WAREHOUSE REMODEL
1 1" = 20'-0"
PHASE 2 - 9TH FLOOR EAST WING
2A
1" = 20'-0"
PHASE 2A - 9TH FLOOR LOBBY
2B
1" = 20'-0"
PHASE 3 - 9TH FLOOR WEST WING
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
ZMiller Image vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil vhawbpSomogM2 Pencil
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
Number:
C :\R ev it
\1 9.
_A
R C
H _R
_z m ill er 4N
R T
Z .r vt 4/
/2
9:
:2
A M
01-I9
CODE DATA RENOVATE 9TH FLOOR MENTAL
HEALTH
1111 EAST END BLVD, WILKES-BARRE, PA 18711
693-19-106
01 & 17
04/18/2023 DR ZAM
100% CONSTRUCTION
DOCUMENTS
VEG 19.25 DWG 08 of 10 F
IN
A L
D R
A W
IN
G
S S
U B
M
IT
T A
L
0 100% CONSTRUCTION DOCUMENTS 04/18/2023
Moist
Yes
Yes (Type IA)
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
Secondary (Emergency Overflow) Drains Yes
Scuppers No
Gutters No
NA
Yes
Yes
Yes
No
Thermoplastic Single-Ply Roofing Yes
Yes
No
Weather Protection - Water-Resistive Barrier (WRB)
Materials
Water-Resistive Barrier (WRB)
Masonry
Metal
B U
IL
D
IN
G
E N
V E
L O
P E
EXTERIOR WALLS (EW)
Climate Zones (IECC)
Climate Zone
Moisture Regimes
Performance Requirements
Vertical and Lateral Flame Propagation (Type I/II/III/IV)
EW = +40 Feet (above Grade Plane) + WRB
Installation of Wall Coverings
Vapor Retarders
Flashing
Exterior Insulation and Finish Systems (EIFS)
Anchored Masonry Veneer
Stone Veneer
Adhered Masonry Veneer
Combustible Materials on the Exterior Side of EW
Metal Composite Materials (MCM)
Exterior Insulation and Finish Systems (EIFS)
High-Pressure Decorative Exterior-Grade Compact Laminates
(HPL)
Coping
Roof Drainage
Attic and Rafter Ventilation
Crickets and Saddles
Performance Requirements
Wind Resistance of Roofs
ROOF ASSEMBLIES
Performance Requirements
Weather Protection
Flashing
Low-Slope Roofs
Aggregate
Requirements for Roof Coverings
Penthouses
Built-Up Roofs
Roof Insulation
Above Deck = NFPA 276 or UL 1256
ROOFTOP STRUCTURES
IA
I (332)
3 Hours
3 Hours
3 Hours
0 Hours
2 Hours
1.5 Hours
NA
NA
NA
Fully Protected
NFPA 13 - 2018
NHC / EHC
NA
(See "Life Safety Plans" … 01-I10 & 17-I11)
NFPA 10 - 2018
Yes
NFPA 72 - 2018
NHC / EHC
No
No
No
No
NA
NA
NA
NA
No
0-Hours (NHC/EHC) : Resist the Passage of Smoke
2-Hours : Penetrating 3-Hr Floor Const
2-Hours : NHC/EHC & EB
NA
2-Hours : Penetrating 3-Hr Floor Const
NA
NA
NA
Yes
Sprinklered
Sprinklered
1FB
Sprinklered
Required - Provided based on NHC
Class B
NA
Class B
Class B
Administrative Spaces Class C
OL = (4) Occupants or Less Class C
Class I or Class II
Yes
Yes (High-Rise Buildng, DE Locks, IES)
0.3
0.2
200 Feet (NHC/EHC)
100 Feet (NHC/EHC)
30 Feet (NHC/EHC)
72 Inches : Hospital for Psychiatric Care
44 Inches : Adjunct Areas
Not Applicable
32" Minimum : Hospital for Psychiatric Care
Yes
Yes
Yes
Yes
Yes
Yes
No
Not Applicable
Not Applicable
(See 01-I9)
Yes
Yes
Yes
Yes
Yes
Yes
NA
(See 01-I9)
No
No
Not Applicable
Yes (Window)
Nonbearing Walls - Interior
Floor Construction & Secondary Members
Roof Construction & Secondary Members
Fire Separation Distance (FSD)
CONSTRUCTION CLASSIFICATION
Construction Classification (IBC)
Construction Classification (LSC)
Building Elements FRR (Hours)
Primary Structural Frame
Bearing Walls - Interior
Bearing Walls - Exterior
Exterior Wall FRR (Hours)
Projections
Standpipe System
FIRE PROTECTION SYSTEMS
Automatic Sprinkler System
Design Criteria
Occupancy(s) & Locations Where Required
Portable Fire Extinguishers (PFE)
Design Criteria
Fire Alarm and Detection Systems
Design Criteria
Occupancy(s) & Locations Where Required
Emergency Voice/Alarm Communications System
Smoke and Heat Removal
Fire Command Center (FCC)
Emergency Alarm System
Smoke Control Systems
Emergency Responder Safety Features
Carbon Monoxide Detection
FIRE-RESISTANCE RATINGS (FRR)
Corridors
Fire Department Connections (FDC)
Fire Pumps
Special Rooms or Spaces
Fire Pump Rooms
Corridor Enclosure FRR (Hours)
Interior Exit Stairway (IES)
Occupancy Separations
Control Areas (Hazardous Materials)
Vertical Openings (VO)
Incidental Uses
Furnace Room (>400K Btu)
Boiler Rooms (Equipment >15 psi & 10 Hp)
Electrical Equipment Rooms (EER)
Elevator Machine Rooms/Control Spaces/Machinery Spaces
Storage Rooms (I-2/ACF, >100 SF)
Corridors and Exit Access Stairway Enclosures
Rooms and Enclosed Spaces
Interior Floor Finish and Floor Covering
INTERIOR FINISHES
Wall and Ceiling Finishes
Interior Wall and Ceiling Finish Materials
Interior Exit Stairways (IES)
Exit Passageways
O C
C U
P A
N T
N E
E D
S OCCUPANT LOAD (OL)
(See "Occupant Load Matrix" on 01-I9)
F
IR
E P
R O
T E
C T
IO
N
PLUMBING FIXTURES (PF)
(See "Plumbing Fixture Matrix" on 01-I9)
Stairways
Other Means of Egress (Doors, Corridors, Aisles, Ramps)
EXIT ACCESS
Travel Distance Requirements
Exit Access Travel Distance (EATD)
Common Path of Egress Travel Distance (CPOETD)
GENERAL MEANS OF EGRESS
Means of Egress - Illumination
Power Source - Normal
Power Source - Emergency Electrical System
Occupant Multiplier Factor (Inches/Occupant)
Dead-End Corridors (DEC)
Corridor Requirements
Corridor Width (Inches)
Door Requirements
Door - Clear Width (Inches)
Hardware
Controlled Egress (Group I-1 and I-2)
Other Means of Egress
Power-Operated Doors?
Security Grilles?
Delayed-Egress Doors?
Electrically Locked Egress Doors?
Electromagnetically Locked Egress Doors?
Stairway Doors
Special Doors
Stairway Requirements
Number of Means of Egress
Ramp Requirements
(2) Means of Egress - Minimum
Maximum OL of Story
OL = 1 - 500 Occupants = (2) Exits or Exit Access
Elevators
Exit Access Stairways (IES)
Accessible Means of Egress (2 per Story)
Accessible Means of Egress Components
Accessible Route (AR)
Two-Way Communication (AoR or EAAR)
EXITS
Number of Exits
Exit Passageways?
Horizontal Exits?
EXIT DISCHARGE
Number of Exit Discharges
Roof Access?
M E
A N
S O
F E
G R
E S
S
OTHER MEANS OF EGRESS
Date of Award : 09.26.2019
ASME Code for Pressure Piping
New Health Care (NHC) & Existing Health Care (EHC)
Existing Business (EB) : IES, Hoistways, Shafts
2-Hour Fire Barrier (2FB)
NA - No Revisions
NA - No Revisions
21,821 GFA
800 SF (Addition) & 800 (Occupied Roof)
21,821 GFA + 800 SF (Addition) = 22,621 GFA
Yes
Yes
Addition & Rehabilitation/Alteration : Building 01 (2022)
A D
M
IN
IS
T
R A
T
IO
N
PROJECT INFORMATION
Owner
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD, WILKES-BARRE, PA 18711
Project / Building
PROJECT NAME : RENOVATE 9TH FLOOR MENTAL HEALTH
PROJECT NUMBER : 693-19-106
REGULATORY
VA Fire Protection Design Manual (8th Edition - 06.01.21)
NFPA National Fire Codes (Exceptions : NFPA 5000 and NFPA 900)
NFPA 101 Life Safety Code - 2018 (LSC)
Referenced Publications (Applicable but not all inclusive)
NFPA 1 Fire Code - 2018
NFPA 10 Standard for Portable Fire Extinguishers - 2018
ASME
Miscellaneous
Occupational, Safety and Health Administration (OSHA) Standards
Building Code Requirements for Reinforced Concrete, ACI and Commentary (ACI 318)
International Plumbing Code - 2018 (IPC)
NFPA 13 Standard for the Installation of Sprinkler Systems - 2019
PROJECT SCOPE
IBC
Addition to Existing (AD)
Addition to Existing (AD)
RENOVATION OF EXISTING SPACE LOCATED ON THE
9TH FLOOR EAST FOR MENTAL HEALTH AND THE
EXISTING WAREHOUSE AREA INTO OFFICE SPACE IN
BUILDING 01. THE NEWLY RENOVATED SPACE WILL
CONSIST OF 24,000 SQ. FT. OF EXISTING MENTAL
HEALTH SPACE ON THE 9TH FLOOR AND 5,000 SQ. FT.
OF EXISTING WAREHOUSE SPACE IN THE BASEMENT
THAT WILL BE RENOVATED INTO OFFICE SPACE.
Reconstruction (RC)
Renovation to Existing
Alteration Level 2 (A2)
LSC
Change of Use (CU)
B U
IL
D
IN
G
P L
A N
N
IN
G
USE AND OCCUPANCY CLASSIFICATION
Addition & Rehabilitation/Alteration : Building 01 (2022)
Occupancy(s) - Main
Separated Occupancies
Required Separation of Occupancies
BUILDING DATA
Addition & Rehabilitation/Alteration : Building 01 (2022)
Building Area
Gross Floor Area (GFA) by Story
Number of Stories
Building Height
Story 09 - Existing
Story 09 - New Addition
Story 09 - Existing + New Addition
Group I-2
Special Detailed Requirements (IBC)
High-Rises (>75'-0" FD Access)
PG-18-13 VA BIM & CAD Standards (02.2017)
PG-18-14 Room Finishes, Door, & Hardware Schedule (04.10.17)
VA DESIGN GUIDES (DG-#-#)
VA PROGRAM GUIDES (PG-#-#)
Architectural Design Manual (08.01.14)
Electrical Design Manual (12.01.19)
Lighting Design Manual (12.01.15)
HVAC Design Manual (11.01.17)
Interior Design Manual (11.01.20)
Physical Security and Resiliency Design Manual (09.01.21)
Plumbing Design Manual (05.01.21)
VA Signage Design Guide (09.01.21)
PG-18-1 VA Master Specifications
Chapter 110 – Mental Health Patient Care Unit (MH PCU)
VA DESIGN MANUALS (DM)
VA DIRECTIVES
PG-18-3 Design & Construction Procedure (07.01.21)
PG-18-4 VA Standard Details
PG-18-5 Equipment Guide List (12.2019)
H-18-8 Seismic Design Requirements (05.01.20)
PG-18-9 Space Planning Criteria (02.21.21)
ASME Boiler and Pressure Vessel Code
PG-18-15 A/E Design Submission Requirements (Volume C - Minor and NRM Projects)
PG-18-17 Environmental Planning Guidance - NEPA Interim Guidance ‐ Projects (09.30.10)
International Code Council (ICC)
PG-18-13 VA Sustainable Design Manual (01.01.17, revised 11.01.18)
NFPA 14, Standard for the Installation of Standpipe and Hose Systems - 2019
NFPA 54, National Fuel Gas Code, 2018
NFPA 72, National Fire Alarm and Signaling Code - 2019
NFPA 80, Standard for Fire Doors and Other Opening Protectives - 2019
NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2018
NFPA 90B, Standard for the Installation of Warm Air Heating and Air-Conditioning Systems, 2018
NFPA 70 National Electrical Code - 2020 (NEC)
International Building Code - 2018 (IBC)
National Fire Protection Association (NFPA)
Architectural Barriers Act Accessibility Standards (ABAAS) 2015
ASHRAE
ASHRAE Standard 15 Safety Code for Mechanical Refrigeration
ASHRAE Standard 34 Designation and Safety Classification of Refrigerants
ASHRAE Standard 90.1
ASHRAE Standard 170 Ventilation of Health Care Facilities
Accessibility
Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings (AISC)
OL OL OL OL
ACCESSORY
MECHANICAL 500 sf ● F-1/2 1,637 sf 4 1,078 sf 3 1,369 sf 3 0 sf 0 4,084 sf 19.9% 10 2.7% 0
STORAGE 300 sf ● S-1/2 771 sf 3 0 sf 0 219 sf 1 0 sf 0 990 sf 4.8% 4 1.1% 0
ASSEMBLY W/O FIXED SEATS
ASSEMBLY - UNCONCENTRATED (CHAIRS & TABLES)
RESTAURANTS 15 sf ● A-2b 0 sf 0 0 sf 0 437 sf 30 0 sf 0 437 sf 2.1% 30 8.2% 30
AUDITORIUMS 15 sf ● A-3a 1,173 sf 79 447 sf 30 1,014 sf 68 0 sf 0 2,634 sf 12.8% 177 48.4% 177
ASSEMBLY - OUTSIDE AREAS
AUDITORIUMS 15 sf ● A-3a 0 sf 0 0 sf 0 0 sf 0 745 sf 50 745 sf 3.6% 50 13.7% 25
BUSINESS AREAS 150 sf ● B 2,156 sf 15 1,460 sf 10 1,724 sf 12 0 sf 0 5,340 sf 26.0% 37 10.1% 28
BUSINESS AREAS - CONCENTRATED 50 sf ● B 253 sf 6 243 sf 5 0 sf 0 0 sf 0 496 sf 2.4% 11 3.0% 11
INSTITUTIONAL AREAS
OUTPATIENT AREAS 100 sf ● B 0 sf 0 279 sf 0 0 sf 0 0 sf 0 279 sf 1.4% 0 0.0% 0
CARE RECIPIENTS I-2a 0 1 0 0 1 0.3% 1
CARE GIVERS I-2b 0 2 0 0 2 0.5% 2
SLEEPING AREAS 120 sf ● I-2a 1,948 sf 0 585 sf 0 2,021 sf 0 0 sf 0 4,554 sf 22.2% 0 0.0% 0
CARE RECIPIENTS I-2a 10 5 11 0 26 7.1% 26
CARE GIVERS I-2b 7 0 6 0 13 3.6% 13
KITCHENS 100 sf ● B 0 sf 0 0 sf 0 191 sf 2 0 sf 0 191 sf 0.9% 2 0.5% 2
LOCKER ROOMS 50 sf ● B 0 sf 0 114 sf 3 0 sf 0 0 sf 0 114 sf 0.6% 3 0.8% 3
NON-NET FLOOR AREA 168 sf 226 sf 205 sf 55 sf 599 sf 2.9%
8,106 sf 124 4,432 sf 59 7,180 sf 133 800 sf 50 20,518 sf 100% 366 100% 318
65 75 54 16 56
DTBT CTA B0 C0 B1 C1 B2
Total
OL
(PF)
2021 NFPA 101 LSC Table 7.3.1.2 Total Occupant Load (MOE)
C la ss ifi ca tio n
FUNCTION OF SPACE
N et C2 B3 C3
Wilkes-Barre VA (19.25) - Renovate 9th Floor Mental Health
SC-09A SC-09B SC-09C + Addition Occupied Roof
STORY 09 - Bldg 01 TOTALS
TOTALS : Areas & Occupant Loads
AVERAGE OL FACTOR
Total Area
BT% CT%
Total
OL
A re a/ O cc
G ro ss
Area Area Area Area
OL
Assembly (Restaurants, Banquet Rooms, & Food Courts) A-2b 30 15 0.08 0.08 0.06
Assembly (Auditoriums, Lecture Halls & Libraries) A-3a 202 101 0.51 0.51 0.40
Business B 44 22 0.55 0.55 0.44
Institutional (Hospitals, Ambulatory Nursing Home Care) I-2a 27 14 13.00 13.00 0.27
Institutional (Employees, other than Residential Care) I-2b 15 8 0.23 0.23 0.15
Institutional (Visitors, other than Residential Care) I-2c 0 0 0.00 0.00 0.00
318 160
14.4 14.4 1.3
15 15 2
0 0
0 0
0 0
TOTALS - Care Recipients (Provided) : WCs + LAVs + DFs
TOTALS (Provided) : UNISEX 16
TOTALS - Care Givers (Provided) : WCs + LAVs + DFs
TOTALS - Care Givers (Provided) : UNISEX 2
TOTALS - Visitors (Provided) : WCs + LAVs + DFs
TOTALS - Visitors (Provided) : UNISEX 1
TOTALS (Required) : WCs + LAVs + DFs
Wilkes-Barre VA (19.25) - Renovate 9th Floor Mental Health
Classification (Description)
Plumbing Fixtures (IBC Table 2902.1)
STORY 09 - Bldg 01
T O
T A
L O
L
Lav
DF
(M)(F) (M) (F)
TOTALS : Areas, Occupant Loads & Egress Widths
TOTALS : WCs + LAVs + DFs
0.3
0.2
A Stair 0.3 44 44 / 0.30 146
B Door (into Stairway) 0.2 36 33.5 / 0.20 = 167
C Door (Exit Discharge) 0.2 36 33.5 / 0.20 = 167
A Stair 0.3 44 44 / 0.30 146
B Door (into Stairway) 0.2 36 33.5 / 0.20 = 167
C Door (Exit Discharge) 0.2 36 33.5 / 0.20 = 167
A Stair 0.3 44 44 / 0.30 146
B Door (into Stairway) 0.2 36 33.5 / 0.20 = 167
C Door (Exit Discharge) 0.2 36 33.5 / 0.20 = 167
A Stair 0.3 44 44 / 0.30 146
B Door (into Stairway) 0.2 36 33.5 / 0.20 = 167
C Door (Exit Discharge) 0.2 36 33.5 / 0.20 = 167
Wilkes-Barre VA (19.25) - Renovate 9th Floor Mental Health
Exit Components
M u lt ip lie r
Story 09 - Bldg 01
S iz e (I n
C lr
W id th
In
M u lt ip lie r
O cc u p an ts
L o w es t O
L
Stair Multiplier
Door Multiplier
Interior Exit Stairway 02 (IES-02-09)
Interior Exit Stairway 03 (IES-03-09)
Interior Exit Stairway 01 (IES-01-09)
Occ Load Demand (Calculated) 366
584Occ Load Capacity (Calculated)
Interior Exit Stairway 05 (IES-05-09)
UP
A B C D E F G H J K L M N O P Q R S T U V
MEN'S
QUIET
ROOM
MEN'S
BARIATRIC
GROUP
THERAPYMEN'SMEN'SMEN'S
ANTE
ROOM
HEAD
NURSE
OFFICE
WOMEN'S
NURSE'S
STATION
WOMEN'S
BARIATRICGERIATRIC
BARIATRIC
GERIATRIC
CLEAN
UTILITY
DAY/TV
GROUP
THERAPY
BARIATRIC
GERIATRIC
NURSE'S
STATION
SALLY
PORT
MEETING
WOMEN'S
WOMEN'S
MECHANICAL
CONFERENCE
ELEVATOR
LOBBY
WORKSTATIONS
ELECTRICAL
MECHANICAL
TELECOM
ROOM
SALLY
PORT
STAFF
TOILET
NURSE'S
LOUNGE
MECH
ELEVATOR
LOBBY
ELEVATOR
LOBBY
SALLY
PORT
SERVING
KITCHEN
DINING/
ACTIVITIES
MEN'S MEN'S
MEN'S
BARIATRIC
OFFICE
MECHANICAL
EAST
SUNROOM
EXAM/
INTAKE
LOBBY
MED
OFFICE
TEAMING/
COUNSELING
MED
NURSE'S
WORKROOM
INTERVIEW
GROUP
COUNSELING
ROOM
HAC
STAIR
LOCKERS
ELEVATOR
ELEVATOR
STAIR
STAIR
STAIR ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
LINEN
PATIENT
STORAGE
CLEAN
STORAGE
ELEC
ELEC
ELEC
HAC
ELEC
SOILED
UTILITY LAUNDRY
ELEC
ELEC
ELEC
ELEC
LAUNDRY
CORRIDOR
CORRIDOR
C O
R R
ID
O
R
STAFF
TOILET
TOILET
C O
R R
ID
O
R
CORRIDOR
SECLUSION
ROOM
OFFICE/
GROUP
ROOM
STORAGE
HAC
PREFUNCTION/
COLLABORATION
CORRIDOR
COURTYARDCORRIDOR
CORRIDOR
SHAFT
CORRIDOR
Assembly T&C (15) 326 sf
Assembly T&C (15) 137 sf
Assembly T&C (15) 437 sf
Assembly T&C (15) 218 sf
Assembly T&C (15) 137 sfAssembly T&C (15)
219 sf
Assembly T&C (15) 300 sf
Assembly T&C (15) 136 sf
Assembly T&C (15) 161 sf
Assembly T&C (15) 68 sf
Assembly T&C (15) 168 sf
Assembly T&C (15) 121 sf
Assembly T&C (15) 310 sf
10 sf
22 sf
15 sf 12 sf
13 sf
60 sf
36 sf
18 sf
138 sf
21 sf
23 sf
Non-Net (0) 30 sf
Kitchen (200) 191 sf
Mech (0) 724 sf
Mech (0) 147 sf
Mech (0) 443 sf
Mech (0) 69 sf
Mech (0) 151 sf
Mech (0) 71 sf
Mech (0) 58 sf
Mech (0) 114 sf
Mech (0) 816 sf
Storage (300) 115 sf
Storage (300) 92 sf Storage (300)
110 sf
Storage (300) 205 sf
Mech (0) 270 sf
Mech (0) 531 sf
Mech (0) 78 sf
Mech (0) 346 sf
Mech (0) 151 sf
Sleeping Areas (120) 284 sf
Sleeping Areas (120) 247 sf
Sleeping Areas (120) 273 sf
Sleeping Areas (120) 274 sf
Sleeping Areas (120) 288 sf
Sleeping Areas (120) 272 sf
Sleeping Areas (120) 316 sf
Sleeping Areas (120) 295 sf
Sleeping Areas (120) 287 sf
Sleeping Areas (120) 280 sf Sleeping Areas (120)
276 sf
Sleeping Areas (120) 279 sf
Sleeping Areas (120) 312 sf
Sleeping Areas (120) 294 sfSleeping Areas (120)
293 sf
Storage (300) 35 sf
Storage (300) 167 sf
Sleeping Areas (120) 290 sf
Storage (300) 50 sf
Storage (300) 16 sf
Storage (300) 83 sf
Mech (0) 33 sf
Locker Rm (50) 114 sf
Mech (0) 50 sf
Business Areas (50) 253 sf
Storage (300) 70 sf
Storage (300) 47 sf
Mech (0) 32 sf
Outpatient Areas (120) 135 sf
Outpatient Areas (120) 144 sf
Business Areas (50) 243 sf
1SB
1S B
1S B
1S B
1S B
1S B
1SB
1S B
1S B
1SB
1SB
1SB
1SB
1SB
1S B
1SB
1SB
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1SB
1S B
1S B
1SB
1S B
1S B
1S B
1S B
1SB
1SB
Assembly T&C (15) 333 sf
Non-Net (0) 131 sf
Assembly T&C (15) 745 sf
Mech (0)Storage (300)Assembly T&C (15) Kitchen (200)Business Areas (150)Non-Net (0) Business Areas (50) Lockers (50)Sleeping Areas (120)Outpatient Areas (120)Assembly T&C (15) Dining
26 sf
OCC ROOFSC-09A SC-09B SC-09C + Addition
Non-Net (0)
2 2
2 2 2
UP
A B C D E F G H J K L M N O P Q R S T U V
MEN'S
QUIET
ROOM
MEN'S
BARIATRIC
GROUP
THERAPYMEN'SMEN'SMEN'S
ANTE
ROOM
HEAD
NURSE
OFFICE
WOMEN'S
NURSE'S
STATION
WOMEN'S
BARIATRICGERIATRIC
BARIATRIC
GERIATRIC
CLEAN
UTILITY
DAY/TV
GROUP
THERAPY
BARIATRIC
GERIATRIC
NURSE'S
STATION
SALLY
PORT
MEETING
WOMEN'S
WOMEN'S
MECHANICAL
CONFERENCE
ELEVATOR
LOBBY
WORKSTATIONS
ELECTRICAL
MECHANICAL
TELECOM
ROOM
SALLY
PORT
STAFF
TOILET
NURSE'S
LOUNGE
MECH
ELEVATOR
LOBBY
ELEVATOR
LOBBY
SALLY
PORT
SERVING
KITCHEN
DINING/
ACTIVITIES
MEN'S MEN'S
MEN'S
BARIATRIC
OFFICE
MECHANICAL
EAST
SUNROOM
EXAM/
INTAKE
LOBBY
MED
OFFICE
TEAMING/
COUNSELING
MED
NURSE'S
WORKROOM
INTERVIEW
GROUP
COUNSELING
ROOM
HAC
STAIR
LOCKERS
ELEVATOR
ELEVATOR
STAIR
STAIR
STAIR ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
LINEN
PATIENT
STORAGE
CLEAN
STORAGE
ELEC
ELEC
ELEC
HAC
ELEC
SOILED
UTILITY LAUNDRY
ELEC
ELEC
ELEC
ELEC
LAUNDRY
CORRIDOR
CORRIDOR
C O
R R
ID
O
R
STAFF
TOILET
TOILET
C O
R R
ID
O
R
CORRIDOR
SECLUSION
ROOM
OFFICE/
GROUP
ROOM
STORAGE
HAC
PREFUNCTION/
COLLABORATION
CORRIDOR
COURTYARDCORRIDOR
CORRIDOR
SHAFT
CORRIDOR
SC-09A
8,106 sf
SC-09B
4,432 sf
SC-09C
7,180 sf1SB
1SB
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1SB
1S B
1S B
1S B
1SB
1SB
1SB
1SB
1SB
1SB
1SB
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1SB
1S
B 1S
B 1S
B 1S
B
1SB
1S B
1S B
1S B
1S B
1S B
1S B
1S B
1SB
1SB
1SB
SC
SC
SC
SC
MOST REMOTE SCTD A =
157 FEET < 200 FEET
MOST REMOTE SCTD B =
141 FEET < 200 FEET
MOST REMOTE SCTD C1 =
184 FEET < 200 FEET
MOST REMOTE SCTD C2 =
176 FEET < 200 FEET
9 3
Patients in Smoke Compartment (SC)
Patients in Sleeping Rooms#
2 2
2 2 2
OCC ROOF
877 sf
UP
A B C D E F G H J K L M N O P Q R S T U V
MEN'S
QUIET
ROOM
MEN'S
BARIATRIC
GROUP
THERAPYMEN'SMEN'SMEN'S
ANTE
ROOM
HEAD
NURSE
OFFICE
WOMEN'S
NURSE'S
STATION
WOMEN'S
BARIATRICGERIATRIC
BARIATRIC
GERIATRIC
CLEAN
UTILITY
DAY/TV
GROUP
THERAPY
BARIATRIC
GERIATRIC
NURSE'S
STATION
SALLY
PORT
MEETING
WOMEN'S
WOMEN'S
MECHANICAL
CONFERENCE
ELEVATOR
LOBBY
WORKSTATIONS
ELECTRICAL
MECHANICAL
TELECOM
ROOM
SALLY
PORT
STAFF
TOILET
NURSE'S
LOUNGE
MECH
ELEVATOR
LOBBY
ELEVATOR
LOBBY
SALLY
PORT
SERVING
KITCHEN
DINING/
ACTIVITIES
MEN'S MEN'S
MEN'S
BARIATRIC
OFFICE
MECHANICAL
EAST
SUNROOM
EXAM/
INTAKE
LOBBY
MED
OFFICE
TEAMING/
COUNSELING
MED
NURSE'S
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .