36C24419B0044-005.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24419B0044
About this file
36C24419B0044 Attachment 4 - Wilmington 77_101098_SET.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24419B0044-0001006.pdf | ||
| 36C24419B0044-0001003.xlsx | XLSX spreadsheet | |
| 36C24419B0044-0001004.xlsx | XLSX spreadsheet | |
| 36C24419B0044-0001005.pdf | ||
| 36C24419B0044-0001000.docx | DOCX document | |
| 36C24419B0044-0001001.pdf | ||
| 36C24419B0044-0001002.pdf | ||
| 36C24419B0044-012.docx | DOCX document | |
| 36C24419B0044-017.docx | DOCX document | |
| 36C24419B0044-016.docx | DOCX document | |
| 36C24419B0044-015.docx | DOCX document | |
| 36C24419B0044-004.pdf | ||
| 36C24419B0044-007.pdf | ||
| 36C24419B0044-003.xlsx | XLSX spreadsheet | |
| 36C24419B0044-011.docx | DOCX document | |
| 36C24419B0044-019.docx | DOCX document | |
| 36C24419B0044-020.docx | DOCX document | |
| 36C24419B0044-001.docx | DOCX document | |
| 36C24419B0044-002.pdf | ||
| 36C24419B0044-010.docx | DOCX document | |
| 36C24419B0044-014.docx | DOCX document | |
| 36C24419B0044-008.pdf | ||
| 36C24419B0044-006.pdf | ||
| 36C24419B0044-013.doc | DOC document | |
| 36C24419B0044-018.docx | DOCX document | |
| 36C24419B0044-009.docx | DOCX document | |
| 36C24419B0044-000.docx | DOCX document |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
SIGNOFF / APPROVAL NOTES
1. The ceiling minimum structure capacity must be able to support the load specified on the installation drawing.
2. Electrical power source outlet already available by the facility, position to be verified in the field.
3. Guldmann Inc. reserves the right to slightly modify the track layout if necessary without Facility approval.
4. Guldmann Inc. will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process of which we have not been advised.
5. Modifications of door headers by the facility.
6. Signed drawings are required prior to ordering and installation of ceiling lifts.
This signature of each drawing confirms agreement of all the conditions listed above.
7. Systems are tested at 1.5 times capacity.
550 lbs. tested at 825 lbs.; 770 lbs. tested at 1155 lbs.; 825 lbs. tested at 1238 lbs.; 1100 lbs. tested at 1650 lbs.
MY SIGNATURE BELOW VERIFIES THAT I HAVE:
Reviewed all _____ pages, with a total quantity of _____ room(s), _____ system(s) for the approbation of layout for each room and the approbation of structure for each room.
CUSTOMER
APPROVAL: _____________________________________ DATE: _______________
DATE: DRAWN BY:
Wilmington VA
WILMINGTON 77
1601 Kirkwood Hwy.
Wilmington, DE 19805
PROJECT ID: 101098
WILMINGTON 77
FACILITY SIGNOFF
GUL101
36 72 65
STE08/15/18
1. HOIST = 450 / 605 / 825 / 880 LBS
BUILT TO 825 / 1100 LBS
2. NON-RECESSED / OVER/UNDER /
BOXED
3. CEILING HEIGHT = VARIES
4. AFF TO DECK = VARIES
5. ATTACHMENT TYPE =
METAL PAN /
I - BEAM, SPAN = VARIES
6. 90° CURVE
7. 90° CURVE LONG
8. 30° CURVE
9. 45° CURVE
Revision Schedule
Date Issued by Number Description
2 OPTIONS FOR
TYP PAT RM A & B
CONFIRM ALL CEILING
AND DECK HEIGHTS
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GEN. DETAIL
GUL102
STE08/15/18
PROJECT ID: 101098
Rail A Rail B Rail C Rail A Rail B Rail C
Weight: 2.6 kg/m Weight: 5.0 kg/m Weight: 6.0 kg/m
(5.72 lbs/m) (11 lbs/m) (13.2 lbs/m) m m
(6 /3 m m
(5
,5 m m
(2 /4
62 mm
(2 1 /2 ")
62 mm
(2 1 /2 ")
62 mm
(2 1 /2 ")
A
B
C
RAIL
SPAN LIMITS BASED ON HOIST SIZE
CANTILEVER
9"
27"
47"
450 lbs 560lbs 660 lbs 770 lbs 1100 lbs
78" 68" 59" 59" 49"
206" 187" 177" 157" 137"
314" 285" 265" 246" 206"
825 lbs
49"
157"
236"
E
B
D
A
C
F
G
Combi-Lock systems with traverse rail with short cut-out (e.g. System N) have a MAX. SWL at 375 kg (825 lbs).
A: 114 mm (4 1/2") B: 99 mm (4") C: 175 mm (6 3/4") D: 100 mm (4") E: 119 mm (4 3/4") F Min: 50mm (2") G: 350 mm (1' 1 3/4")
MAX. 375 kg COMBI
A rail
GH3 Hoist
M
in. 190 (7
1/2")
66 (2 5 /8")
62 (2 7 /16")
226 (8 15 /16 ")
65 (2 9/16")
58.5 (2 1/4")
205 (8 1 /16")
Door Cut - Hoist
77 [3"]
CENTER OF DOOR
DOOR STOP
[3
278 [11"]
Door Cut - Rail
G
F
DC
E
B
A
GH3 and GH3+
SWL : 200 kg (440 lbs), 250 kg (550 lbs)
Own weight : 9,6 kg (21.1 lbs), 14,2 kg (31 lbs) With horizontal motor : 10,5 kg (23.1 lbs), 15,9 kg (35 lbs) With scale / horizontal motor : 11,1 kg (24.5 lbs), 17,3 kg (38 lbs)
: 300 kg (660 lbs), 350 kg (770 lbs) : 375 kg (825 lbs)
Dimensions
A : 580 mm (23 1 /4")
B : 345 mm (13 3 /4")
C : 156 mm (6 1 /4")
D : 184 mm (7 1 /2")
E, min : 82 mm (3 1 /4")
F, min : 445 mm (17 3 /4")
G : 2.500 mm (100")
Depth of hoist : 205 mm (8 1 /4")
Electronics
On/off: : Automatic when used. Soft start/stop. Overload protection.
SWL: 200 kg (440 lbs) Battery : 1 x 24 V NiMH Max charge time : 2 Hours
SWL : 250 kg (440 lbs) Battery : 2 x 24 V NiMH Max charge time : 4 Hours
SWL : 300 kg (660 lbs), 350 kg (770 lbs), 375 kg (825 lbs) Battery : 2 x 24 V NiMH Max charge time : 4 Hours
SWL : 500 kg (1100 lbs) Battery : 4 x 24 V NiMH Max charge time : 8 Hours
Battery protection : At battery voltage below 22V the indicator light turns orange. The hoist stops if voltage falls below 20V.
Power supply : 33 V AC, 2.5 A
Supply voltage, transformer : 100-115/230V AC, 50/60 Hz
Protection classification (IP) according to IEC 60529 Lifting module: IP 20 Hand Control: IP 44 Remote control: IP 20 Transformer: IP 20 Declaration of conformity This hoist is manufactured in compliance with the EuropeaniVledical Device Directive 93/42/EEC - with amendments, as Medical'Device Class I.
1. HOIST = 450 / 605 / 825 / 880 LBS
BUILT TO 825 / 1100 LBS
2. NON-RECESSED / OVER/UNDER /
BOXED
3. CEILING HEIGHT = VARIES
4. AFF TO DECK = VARIES
5. ATTACHMENT TYPE =
METAL PAN /
I - BEAM, SPAN = VARIES
6. 90° CURVE
7. 90° CURVE LONG
8. 30° CURVE
9. 45° CURVE
Rev. Date Issued by Rev.
K B
-T Z
/8
X 3 3
/4
EXISTING CONCRETE
SLAB F'c= 3.0 ksi MIN.
4,8
M
A X
45° to 90°
A9
7,3
7" MIN.
VARIES
GULDMANN RAIL
DETAIL A
DRAWINGS APPROVED FOR THE GULDMANN
GH-3 1100 POUNDS LIFTER SYSTEM STANDARD
INSTALLATION OF SUPPORT AND CONNECTION
METAL PAN DECK. SYSTEM TESTED AT 1650 LBS.
SYSTEMS INSTALLED FOR 770 POUNDS WILL BE
TESTED AT 1155 POUNDS.
SYSTEMS INSTALLED FOR 550 POUNDS WILL BE
TESTED AT 825 POUNDS.
METAL PAN DECK
TAG ITEM NUMBER DESCRIPTION QTY
HTHRO37 12B7
377885
1137024
33219
550439
550481-US
550435
387510
407555
411752
1" Ø-6013-T6 AL TUBE-Guldmann
3/8" B7 THREADED ROD
MQA-F SADDLE NUT 3/8"
3/8" NYLON NUT
3/8"X 1-1/4" FLAT WASHERS
STABILIZER BRACKET - KIT Guldmann
CEILING BRACKET - KIT Guldmann
3/8"X 3-3/4" KB-TZ ANCHOR
1 5/8" X 16"STRUT
3/8" HEX NUT
SIGNATURE: DATE:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
DATE: DRAWN BY:
Wilmington VA
WILMINGTON 77
1601 Kirkwood Hwy.
Wilmington, DE 19805
PROJECT ID: 101098
INSTALLATION SIGNOFF
GUL103
STE08/15/18
DETAIL A
DRAWINGS APPROVED FOR THE GULDMANN
GH-3 1100 POUNDS LIFTER SYSTEM STANDARD
INSTALLATION OF SUPPORT AND CONNECTION
I - BEAM SYSTEM TESTED AT 1650 LBS.
SYSTEMS INSTALLED FOR 770 POUNDS WILL BE
TESTED AT 1155 POUNDS.
SYSTEMS INSTALLED FOR 550 POUNDS WILL BE
TESTED AT 825 POUNDS.
I - BEAM
TAG ITEM NUMBER DESCRIPTION QTY
TBD
HTHR037-12B7
550439
550481-US
550435
377885
411764
33219
TBD
MQA-F SADDLE NUT 3/8"
STRUT
3/8" B7 THREADED ROD
STABILIZER BRACKET - KIT Guldmann
1" Ø-6013-T6 AL TUBE-Guldmann
CEILING BRACKET - KIT Guldmann
3/8" X 1-1/4" BOLT
3/8" X 1-1/4" WASHER
BEAM CLAMP
*ITEM TOO SMALL TO IDENTIFY
9 35550 NYLON NUT 1
8 8
A
GULDMANN RAIL
SIGNATURE: DATE:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
DATE: DRAWN BY:
Wilmington VA
WILMINGTON 77
1601 Kirkwood Hwy.
Wilmington, DE 19805
PROJECT ID: 101098
INSTALLATION SIGNOFF
GUL103.1
/8
H O
IS
T
C E
IL
IN
G
/8
T R
A V
E R
S E
GUL104
COMBI LOCK
BRACING FOR
COMBI LOCK
/8
/2
/8
TRAVERSE
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
PROJECT DETAILS
GUL104
STE08/15/18
PROJECT ID: 101098
1. HOIST = 450 / 605 / 825 / 880 LBS
BUILT TO 825 / 1100 LBS
2. NON-RECESSED / OVER/UNDER /
BOXED
3. CEILING HEIGHT = VARIES
4. AFF TO DECK = VARIES
5. ATTACHMENT TYPE =
METAL PAN /
I - BEAM, SPAN = VARIES
6. 90° CURVE
7. 90° CURVE LONG
8. 30° CURVE
9. 45° CURVE
Rev. Date Issued by Rev.
SEE GUL102 FOR
DOOR CUTS
3/4" = 1'-0"
TYP PAT RM A OPT 1 - HEIGHTS
3" = 1'-0"
COMBI DETAIL
B A
S E
D O
N
C
E
IL
IN
G
/4
T R
A V
E R
S E
H O
IS
T
GUL104.1
/4
/2
TRAVERSE
C E
IL
IN
G
/4
T R
A V
E R
S E
H O
IS
T
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
PROJECT DETAILS
GUL104.1
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1. HOIST = 450 / 605 / 825 / 880 LBS
BUILT TO 825 / 1100 LBS
2. NON-RECESSED / OVER/UNDER /
BOXED
3. CEILING HEIGHT = VARIES
4. AFF TO DECK = VARIES
5. ATTACHMENT TYPE =
METAL PAN /
I - BEAM, SPAN = VARIES
6. 90° CURVE
7. 90° CURVE LONG
8. 30° CURVE
9. 45° CURVE
3/4" = 1'-0"
TYP SHOWER RM - HEIGHTS
3" = 1'-0"
BOXED B-RAIL DETAIL
3/4" = 1'-0"
TYP BAY - HEIGHTS
C E
IL
IN
G
/8
T R
A V
E R
S E
/8
H O
IS
T
C E
IL
IN
G
/8
T R
A V
E R
S E
/8
H O
IS
T
C E
IL
IN
G
/8
T R
A V
E R
S E
/8
H O
IS
T
COORDINATE
WITH EXISTING
EQUIPMENT
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
PROJECT DETAILS
GUL104.2
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1. HOIST = 450 / 605 / 825 / 880 LBS
BUILT TO 825 / 1100 LBS
2. NON-RECESSED / OVER/UNDER /
BOXED
3. CEILING HEIGHT = VARIES
4. AFF TO DECK = VARIES
5. ATTACHMENT TYPE =
METAL PAN /
I - BEAM, SPAN = VARIES
6. 90° CURVE
7. 90° CURVE LONG
8. 30° CURVE
9. 45° CURVE
3/4" = 1'-0"
2169 - HEIGHTS
3/4" = 1'-0"
3238 - HEIGHTS
3/4" = 1'-0"
TYP X-RAY RM - HEIGHTS
UNDER
RECOMMENDED
LIFTING HEIGHT
W1
W1A
PATIENT
ROOM
BATH
ROOM
/8
CENTER OF DOOR
CENTER OVER TOILET
GUL104
A
8' - 5"
22' - 1 3/8"
/2
/8
/8
/4
V
IF
/8
/2
2' - 2 5/8"
1 5/8" 6' - 9 3/8" 1 5/8"
CHARGING
OVER TOILET
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM A OPT 1
GUL105
STE08/15/18
PROJECT ID: 101098
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
Rev. Date Issued by Rev.
1/4" = 1'-0"
TYP PAT RM A OPT 1
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
6. 90° CURVE
REFERENCE FOR 3 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
A. UNKNOWN CURTAIN
JUMP LOCATIONS VIF
TYP PAT RM A
OPTION 1
ADDITIONAL
TRANSFORMERS
REQUIRED TO CHARGE
IN BEDROOM
E15
E15A
PATIENT
ROOM
TOILET
CENTER
OF DOOR
9' - 4 1/4"
7' - 11 1/4" 1' - 1 3/4"
TURN
TABLE
9' - 1 1/8"
9' - 1 1/8"
/8
8' - 5"8' - 5" 3 1/4"3 1/4"
/8
/8 " 1' - 3 7/8"
2' - 1 5/8"
2' - 2 5/8"
/4
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM A OPT 2
GUL106
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
REFERENCE FOR 3 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1/4" = 1'-0"
TYP PAT RM A OPT 2
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
6. 90° CURVE
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
Wall switch for Turntable
TYP PAT RM A
OPTION 2
W4 W3
W3A
PATIENT
ROOM
PATIENT
ROOM
TOILET
8' - 1 3/4"
7' - 5 3/4"3 1/4"
1' - 10"
8' - 1 3/4"
7' - 5 3/4" 3 1/4"
1' - 10"
CENTER OF DOOR CENTER OF DOOR
7 7
6 6
6' - 5 1/4"
" 5' - 3 1/2" 1' - 1 3/4"
/8
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM B OPT 1
GUL107
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/4" = 1'-0"
TYP PAT RM B OPT 1
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
ONLY ONE HOIST PER
ROOM / BATHROOM AT
ANY TIME
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
6. 90° CURVE
7. 90° CURVE LONG
REFERENCE FOR 14 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
TYP PAT RM B
OPTION 1
W6 W5
W5A
PATIENT
ROOM
PATIENT
ROOM
TOILET
8' - 1 3/4"8' - 1 3/4"
3 1/4" 7' - 5 3/4"
7' - 5 3/4" 3 1/4"9
/8
/8
1' - 10" 1' - 10"
6 6
CENTER OF DOOR
CENTER OF DOOR
3' - 4 5/8" 6
POSITION RAILS AS
CLOSE AS
POSSIBLE OVER
TOILET
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM B OPT 2
GUL108
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/4" = 1'-0"
TYP PAT RM B OPT 2
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
6. 90° CURVE
7. 90° CURVE LONG
REFERENCE FOR 14 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
TYP PAT RM B
OPTION 2
W
W A
P A
TIEN
T R O O M
TO
ILET
POTENTIAL CURTAIN JUMP
REQUIRES SPECIAL HOIST
MAX SPAN
13' - 1 1/2"
2' - 11 1/2"
15' - 0 1/8"
1' - 1 3/4"
/4
/4
/4
5' - 11 1/2"1"
1 5/8"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
W7
GUL109
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
3/8" = 1'-0"
W7
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
7. 90° CURVE LONG
SEE GUL200 AND GUL200.1 FOR ROOM LIST
W A
B A
TH
P A
TIEN
T R O O M
R O O M 8
9' - 10 1/8"
1' - 1 5/8"8' - 7 3/8"
CENTER OF DOOR
2' - 9 1/8"
1' - 11 3/8"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM C
GUL110
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
3/8" = 1'-0"
TYP PAT RM C
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
8. 30° CURVE
W A
T O
ILET
P A
TIEN
T R O O M
9' - 5 3/4"
2' - 11 1/4"7' - 9 1/2"
CENTER
OF DOOR
5' - 11 1/2"
/4
4' - 7 3/8"1' - 1 3/4"
3' - 5 1/4"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM D
GUL111
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
REFERENCE FOR 4 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
3/8" = 1'-0"
TYP PAT RM D
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
I-BEAM, SPAN 8' - 10"
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
W19
W18
SHOWER ROOM
GUL104.1
/8
13' - 1 1/2"1"
/8
/4
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP SHOWER RM
GUL112
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1/2" = 1'-0"
TYP SHOWER RM
KEY
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
Hoist Transformer
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 1100 LBS.
2. NON-RECESSED / BOXED.
3. CEILING HEIGHT = UNKNOWN
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
E-5
E5A
PATIENT
ROOM
TOILET
/8
9' - 10 1/8"
16' - 4" 4"
/8
/8
4' - 0 3/4"
/8
/4
/4
6' - 7" 1"
CENTER
OF DOOR
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM E
GUL113
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
REFERENCE FOR 4 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
3/8" = 1'-0"
TYP PAT RM E
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
6. 90° CURVE
LARGE EXAM
8' - 11 7/8"
9' - 2 3/8" 3 1/4"
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL114
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/2" = 1'-0"
SEE GUL200 AND GUL200.1 FOR ROOM LIST
KEY
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
Hoist Transformer
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 1100 LBS.
2. NON-RECESSED / BOXED.
3. CEILING HEIGHT = UNKNOWN
4. AFF TO DECK = UNKNOWN
METAL PAN
CORRIDOR
BONE DENSITOMETRY
ROOM
/2
11' - 5 3/4"
11' - 8 1/4" 3 3/8"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL115
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
SEE GUL200 AND GUL200.1 FOR ROOM LIST
KEY
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
Hoist Transformer
3/8" = 1'-0"
EQUIPMENT LAYOUT UNKNOWN
FINAL RAIL PLACMENT VIF
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 1100 LBS.
2. NON-RECESSED / BOXED.
3. CEILING HEIGHT = UNKNOWN
4. AFF TO DECK = UNKNOWN
2149a
2148a
X-RAY ROOM
CONTROL
AREA
GUL104.2
9' - 10 1/8"
8' - 6 1/8"1' - 2 1/4"
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP X-RAY RM
GUL116
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
3/8" = 1'-0"
TYP X-RAY RM
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
EQUIPMENT LAYOUT UNKNOWN
FINAL RAIL PLACMENT, LENGTHS,
AND HEIGHT VIF
COORDINATE WITH EXISTING
EQUIPMENT
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 5"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
METAL PAN
KEY
A rail
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
Hoist Transformer
2150a
RADIOGRAPHIC
FLUOROSCOPIC
CONTROL
AREA
/8
9' - 10 1/8"
17' - 1 1/2"1"
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP RAD RM
GUL117
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
3/8" = 1'-0"
TYP RAD RM
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
EQUIPMENT LAYOUT UNKNOWN
FINAL RAIL PLACMENT, LENGTHS,
AND HEIGHT VIF
COORDINATE WITH EXISTING
EQUIPMENT
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 5"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
METAL PAN
KEY
A rail
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
W H
EE
L C H A
IR
TO
IL
ET
R O O M
W H
EE
L C H A
IR
S
TR
ET
C H
ER
H O
LD
IN
G
W H
EE
L C H A
IR
TO
IL
ET
R O O M
GUL104.2
9' - 10 1/8"
/8
8' - 6 1/8"
FINAL RAIL
PLACEMENT VIF
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL118
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/4" = 1'-0"
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 1100 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 7' - 10"
4. AFF TO DECK = UNKNOWN
5. ATTACHMENT TYPE =
METAL PAN
KEY
A rail
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
SEE GUL200 AND GUL200.1 FOR ROOM LIST
A
EX
AM
TL
T
W
OM
EN
GUL104.2
/8
9' - 3 1/4"
8' - 0 1/2"1' - 1 1/2"
5' - 11 1/4"
4' - 8 1/2" 1' - 2"
/8
1' - 6 5/8"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL119
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/2" = 1'-0"
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 8' - 0"
4. AFF TO DECK = UNKNOWN
ICU#7
11' - 4 1/2" 4"
/8
/8
/8
/2
10 7/8" 1 5/8"
6 6
CURTAIN JUMP
REQUIRES SPECIAL HOIST
CENTER OVER
TOILET
TO
W
ER
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP ICU RM A
GUL120
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
3/8" = 1'-0"
TYP ICU RM A
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 8' - 0"
4. AFF TO DECK = 11' - 10"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 5' - 3"
6. 90° CURVE
FINAL RAIL
PLACEMENT VIF
307 0
IC
U #5
CURTAIN JUMP
REQUIRES
SPECIAL HOIST
/8
/8
CENTER OVER TOILET
1' - 5 1/2"
11' - 2"
9' - 10 5/8"10 1/2"
/8
TO
W
ER
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP ICU RM B
GUL121
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/2" = 1'-0"
TYP ICU RM B
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 8' - 0"
4. AFF TO DECK = 11' - 10"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 5' - 3"
6. 90° CURVE
ICU#2
CURTAIN JUMP
REQUIRES
SPECIAL HOIST
/8
/4
CENTER OVER
TOILET
1' - 1 1/4"
9' - 10 1/8"
8' - 6 1/8" 2' - 6 1/4"
/2
TO
W
ER
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP ICU RM C
GUL122
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
REFERENCE FOR 3 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 8' - 0"
4. AFF TO DECK = 11' - 10"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 5' - 3"
6. 90° CURVE
1/2" = 1'-0"
TYP ICU RM C
PROCEDURE
ICU-1
CURTAIN JUMP
REQUIRES
SPECIAL HOIST
63' - 7 1/4" 1 5/8"
/8
/8
/8
/2
11' - 11 3/8"4' - 5 1/2"
TO
W
ER
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL123
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
FINAL RAIL
PLACEMENT VIF
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 8' - 0"
4. AFF TO DECK = 11' - 10"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 5' - 3"
6. 90° CURVE
3/8" = 1'-0"
BAY 10
GUL104.1
/8
/8
/4
9' - 10 1/8" 1"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP BAY
GUL124
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
1/2" = 1'-0"
TYP BAY
REFERENCE FOR 11 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
KEY
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
Hoist Transformer
FINAL RAIL
PLACEMENT VIF
LENGTHS VARY BY ROOM
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / BOXED.
3. CEILING HEIGHT = 7' - 11"
4. AFF TO DECK = 10' - 10"
4010A
BATH
1 BED
ROOM
8' - 5 1/4"
7' - 9 1/8" 1' - 1 3/4"
5' - 4 3/8"
/8
/8
5' - 9 5/8"
4' - 6 7/8"1' - 1 3/4"
CENTER
OF DOOR
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL125
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
3/8" = 1'-0"
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
I-BEAM, SPAN 9' - 5"
4011A
2 BED
ROOM
BATH
9' - 2 1/8"
8' - 6"4' - 4 3/4"
/8
/8
CENTER OF DOOR
91' - 11 5/8"
6' - 9 1/8"
5' - 5 1/8" 1' - 1 3/4"
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM F
GUL126
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
REFERENCE FOR 4 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 9' - 5"
9. 45° CURVE
FINAL RAIL
PLACEMENT VIF
LENGTHS VARY BY ROOM
3/8" = 1'-0"
TYP PAT RM F
4 017A 2 B
ED
ROOM
B
ATH
CENTER
OF DOOR
9' - 10 1/8"
14' - 3" 4"
/8
/4
3' - 4 1/8" 1' - 1 3/4"
/8
4' - 8 1/4"
7' - 3 1/2"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
GUL127
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
SEE GUL200 AND GUL200.1 FOR ROOM LIST
3/8" = 1'-0"
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 9' - 5"
6. 90° CURVE
7. 90° CURVE LONG
4 0 A
B
ED
RO
OM
B
AT
H
CENTER OF DOOR
/4
/8
6' - 8 1/8" 1"
/4
/4
9' - 10 1/8"
15' - 3 3/4" 4"
/8
/4
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM G
GUL128
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 9' - 5"
9. 45° CURVE
3/8" = 1'-0"
TYP PAT RM G
4 0304 030A
1 B E D
R OOMB
ATH
CENTER OF DOOR
/8
9' - 7 1/8"
1' - 10 5/8"
8' - 3"1' - 3 3/4"
5' - 1 1/8"
3' - 9" 1' - 3 3/4"
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM H
GUL129
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1/2" = 1'-0"
TYP PAT RM H
ROOMS 4030 AND 4033 NEED TO BE EVALUATED FOR STEEL LAYOUT
I-BEAM SPAN
VARIES FROM
10' - 10" TO 11' - 5"
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
I-BEAM, SPAN VARIES
4 031A
2 B
ED
ROOM
B
ATH
CENTER
OF DOOR
8' - 8"
7' - 11 7/8"4' - 6 7/8"
/8
/8
3' - 6" 1' - 3 3/4"
4' - 10 1/8"
/8
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM I
GUL130
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
CURTAIN LAYOUT UNKNOWN
MUST BE MODIFIED TO ALLOW
SYSTEM TO FUNCTION
REFERENCE FOR 2 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
3/8" = 1'-0"
TYP PAT RM I
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
5. ATTACHMENT TYPE =
I-BEAM, SPAN VARIES
6. 90° CURVE
FINAL RAIL
PLACEMENT VIF
LENGTHS VARY BY ROOM
ROOMS 4031 AND 4032
NEED TO BE EVALUATED
FOR STEEL LAYOUT
I-BEAM SPAN
VARIES FROM
10' - 10" TO 11' - 5"
4 0 A
B
ED
RO
OM
B
AT
H
9' - 10 1/8"
8' - 6 1/8" 1' - 3 3/4"
CENTER
OF DOOR
/2
4' - 6 1/4"
/8
3' - 2 1/8"1' - 3 3/4"
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
DATE: DRAWN BY:
WILMINGTON 77
TYP PAT RM J
GUL131
STE08/15/18
PROJECT ID: 101098
Rev. Date Issued by Rev.
KEY
A rail
B rail
Ceiling bracket, Extended
Combi-lock
Hoist
Stabilizers
Hoist Transformer
REFERENCE FOR 3 ROOMS, SEE GUL200 AND GUL200.1 FOR ROOM LIST
1. HOIST = SEE GUL200/GUL200.1
BUILT TO 825 LBS.
2. NON-RECESSED / OVER/UNDER.
3. CEILING HEIGHT = 9' - 0"
4. AFF TO DECK = 13' - 0"
5. ATTACHMENT TYPE =
I-BEAM, SPAN 9' - 5"
3/8" = 1'-0"
TYP PAT RM J
FINAL RAIL
LENGTHS VARY BY ROOM
SIGNATURE: DATE:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
DATE: DRAWN BY:
Wilmington VA
WILMINGTON 77
1601 Kirkwood Hwy.
Wilmington, DE 19805
PROJECT ID: 101098
ROOM / HOIST LIST
GUL200
SIGNATURE: DATE:
SHEET DESCRIPTION:
SHEET NO:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
DATE: DRAWN BY:
Wilmington VA
WILMINGTON 77
1601 Kirkwood Hwy.
Wilmington, DE 19805
PROJECT ID: 101098
ROOM / HOIST LIST
GUL200.1
| Sheets |
| GUL101 - FACILITY SIGNOFF |
| GUL102 - GEN. DETAIL |
| GUL103 - INSTALLATION SIGNOFF |
| GUL103.1 - INSTALLATION SIGNOFF |
| GUL104 - PROJECT DETAILS |
| GUL104.1 - PROJECT DETAILS |
| GUL104.2 - PROJECT DETAILS |
| GUL105 - TYP PAT RM A OPT 1 |
| GUL106 - TYP PAT RM A OPT 2 |
| GUL107 - TYP PAT RM B OPT 1 |
| GUL108 - TYP PAT RM B OPT 2 |
| GUL109 - W7 |
| GUL110 - TYP PAT RM C |
| GUL111 - TYP PAT RM D |
| GUL112 - TYP SHOWER RM |
| GUL113 - TYP PAT RM E |
| GUL114 - 1204 |
| GUL115 - 2122 |
| GUL116 - TYP X-RAY RM |
| GUL117 - TYP RAD RM |
| GUL118 - 2169 |
| GUL119 - 3238 |
| GUL120 - TYP ICU RM A |
| GUL121 - TYP ICU RM B |
| GUL122 - TYP ICU RM C |
| GUL123 - 3073 |
| GUL124 - TYP BAY |
| GUL125 - 4010 |
| GUL126 - TYP PAT RM F |
| GUL127 - 4017 |
| GUL128 - TYP PAT RM G |
| GUL129 - TYP PAT RM H |
| GUL130 - TYP PAT RM I |
| GUL131 - TYP PAT RM J |
| GUL200 - ROOM / HOIST LIST |
| GUL200.1 - ROOM / HOIST LIST |
File details come from the government source that posted it.