RFI 6 - SK-T-101.pdf
PDF 336 KB Posted
- Attached to
- Z1DA--528A5-20-508 RENOVATE BUILDING 36
- Solicitation number
- 36C24225B0020
About this file
The file is a detailed architectural sketch (SK-21227-T-101) for fiber optic routing at 23 Mechanic Street, Springville, NY, dated 2025-04-24. The technical drawing shows a comprehensive floor plan with multiple buildings and proposed fiber optic cable installation routes, including specific annotations about new fiber optic connections between buildings 37 and 118. The sketch includes detailed room labeling for various spaces such as IS/IT offices, VRC rooms, storage areas, and operational spaces, with routing details that specify installing fiber optic cables above drop ceilings and implementing firestop penetrations of fire barriers. The drawing provides a precise architectural representation of the proposed network infrastructure routing with a scale of 1"=20'-0".
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24225B0020 0004.docx | DOCX document | |
| 36C24225B0020 0003.docx | DOCX document | |
| Pre-Bid RFI_528A5-20-508 Renovate building 36 -.pdf | ||
| RFI 25 Clarification.pdf | ||
| VA 528A5-20-508 Full Specifications Bldg 36_.pdf | ||
| 36C24225B0020 0002.docx | DOCX document | |
| RFI 1 Clarification.pdf | ||
| RFI 18 Clarification.pdf | ||
| RFI 14 and 36 -ACM -Survey Rpt Canadaigua Bldg-36.pdf | ||
| 36C24225B0020 0001.docx | DOCX document | |
| S04 - Pre-BID Sign-In Sheet - Renovate Building 36.pdf | ||
| P01 - Specs - VA 528A5-20-508 Combined Specifications Bldg 36.pdf | ||
| 36C24225B0020_1.docx | DOCX document | |
| P01 - Submittal Log B36 - 528A5-20-508 Renovate Building 36.pdf | ||
| P01 - DRAWING SET - 528A5-20-508 TEMPORARY POLICE STATION.pdf | ||
| LOS certification - 1.2023.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYPE
TYPE TYPE
2A
A
A
C
UP
DO
W
N
UP
A
EB
X1
7A7C 7B
7D
SB
X1
UP
SB
X2
B
CB
X1
CB
X2
EB
X2
B
[] PO
LIC
E
OP
ER
AT
OR
S
UI
TE
[] IS
/IT
ST
OR
AG
E
[] IS
/IT
OP
ER
AT
OR
S
TE
[] IS
/IT
OF
FI
CE
[] IS
/IT
OF
FI
CE
[] IS
/IT
OF
FI
CE
[] IS
/IT
OF
FI
CE
[] EM
S
HA
C
[] GE
C
ST
OR
AG
E
ST
OR
AG
E
IT
/IS
IT
[] ()VA
CA
NT
[] EN
G
W C
RE
PA
IR
[] EN
G
ST
OR
[] GE
C
W
OO
D
SH
OP
[] PM
&R
W
HE
EL
CH
AI
R
ST
OR
AG
E
[] EN
G
W C
RP
R
[] EN
G
EL
EC
TR
IC
[] EM
S
BA
TH
OF
FI
CE
S
[] IS
/IT
6 IN
FR
MT
N
SY
ST
M
VI
SN
R
GN
4 I
T
IS
/IT
6A OF
FI
CE
BE
ME
NT
IS
/IT
6B OF
FI
CE
DU
NN
IN
G/ W
OO
LE
Y
IS
/IT
6C OF
FI
CE
BE
AT
TI
E
IS
/IT
6D OF
FI
CE
RE
ED
IS
/IT 6E OF
FI
CE
BI
XL
ER
IS
/IT
6F OF
FI
CE
PI
CC
HI
IS
/IT
6G OF
FI
CE
BA
TO
R
IS
/IT
6H CO
NF
ER
EN
CE
R
OO
M
IS
/IT
6I OF
FI
CE
ME
RE
DI
TH
IS
/IT
6K OF
FI
CE
MI
SI
K
IS
/IT
6L OF
FI
CE
BA
RN
AR
D
IS
/IT
6M OF
FI
CE
LU
DW
IG
IS
/IT
6N OF
FI
CE
PI
EG
AR
I
IS
/IT6O OF
FI
CE
RO
GE
RS
/F
IO
RI
NO
IS
/IT6P ST
OR
AG
E
[] IS
/IT
A
CO
PY
R M
[] VR
C
B
HS
S
KE
LL
Y
VR
C
C
BR
EA
K [] {} 17
D
SW CU
TH
BE
RT
SO
N
VR
C
E
SW PA
RK
ER
VR
C
F
GR
OU
P
RM
[] VR
C
G
RN NA
PP
I
VR
C
H
ME
CH
R M
[] EN
G
I
CO
MM
C
AR
E
NO
YE
S
VR
C
J
MH
C
MA
LD
ON
AD
O
VR
C
17 MH
IC
M/
VR
C W
AI
TI
NG
VR
C
16 DA
V
CO
NR
AD
TE
NA
NT
A
DA
V
[] TE
NA
NT
ME
N
W
MN
S
[] EM
S
[] GE
C
OF
FI
CE
[] EM
S
ME
N
14 13
25 26
4 2
19 18 17 16
EB-2
1B1A
EB-1
CB-2
CB-2
CB-1
CB-1 CB-3
25A
SB-1
SB-2
15B
15C
15A
18A
5A
5B
5C
7A
3A
CSL
OFFICE
CANTEEN
PATRIOT BREW
IREDALE
OIT
IT ANALYST
[]CHPLN
STORAGE
CSL
OFFICE
VRC
PRRC
VRC
FOOD STORAGE
DECONG
VRC
PSYCHOL
YUREK
VRC
PSA
NERAD
OIT
IT ANALYST
FOSTER
VRC
NURSE
NOTEBAERT
VRC
SEC. SERV
ENG
ELEC. SVC RM
TENANT (MS)
TRANING/CONF
VACANT
VRC
KITCHEN
VRC
LAUNDRY
VRC
CLAY WORK
VRC
REC STORAGE
CHAPLAIN SVC
CHAPEL
VRC
GROUP RM
VRC
VACANT
VRC
VACANT
EMS
EQUIP
IS/IT
SVC. RM
VRC
STOR[]
EMS
TOILET
EMS
STAFF
EMS
TOILET[]
EMS
TOILET
VRC
STOR
ROBERTS
VRC
SUPPT COORD
14B
CSL
BREAKROOM
24a
KILN
VRC
CSL
OFFICE
CSL
OFFICE
CSL
OFFICE
CSL
OFFICE
CSL
OFFICE
CSL
OFFICE
CSL
OFFICE
21A
LUDWIG RICHMOND
TUNNEL TO BLDG 37TUNNEL TO BLDG 118
NEW FIBER OPTIC FROM B37
ROOM 13 TO B37 ROOM 1A
INSTALL ABOVE DROP CEILING
FIRESTOP PENETRATIONS
OF FIRE BARRIERS, TYP
FIRESTOP PENETRATIONS
OF FIRE BARRIERS, TYP
23 MECHANIC STREET, SPRINGVILLE, NY 14141
SKETCH NO. PROJECT NO. DATE:
SK-21227-T-101 21227
FIBER OPTIC ROUTING
2025-04-24SCALE: 1"=20'-0"
FIBER OPTIC ROUTING1
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DF
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text P
AutoCAD SHX Text
CBX2
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
UP
AutoCAD SHX Text
EXIST.
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text
REF.
AutoCAD SHX Text
REF.
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
NORTH
AutoCAD SHX Text %%uBUILDING #36
AutoCAD SHX Text
%%UGROUND FLOOR PLAN
| Sheets and Views |
| ANSI D-SKETCH |
File details come from the government source that posted it. Updated .