Sound Masking Layout.pdf

PDF 1 MB Posted

Attached to
Z1DA--RENOVATE BUILDING 13CD FOR RESIDENTIAL PROGRAMS MONTROSE VAMC
Solicitation number
36C24223B0004
Issued by

About this file

This document includes a sound masking layout drawing and details for a federal solicitation to renovate Building 13CD at the Montrose VA Medical Center. The sound masking drawing depicts the proposed layout of speakers, volume controls, amplifiers and other sound masking components across 839 square feet. It provides specifications for the types and quantities of speakers, wiring diagrams, transformer locations and load limits. The related federal solicitation seeks offers to renovate residential programs spaces at the Montrose VAMC. The solicitation is identified as number 36C24223B0004 and is issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2.

View the file

Other files

File Type Posted
27 52 23 Attachement.pdf PDF
T-102_2023.01.06.pdf PDF
Amendment 0003 36C24223B0004 Renovate Building 13 CD.pdf PDF
620-20-106 Updated RFI Responses.pdf PDF
27 52 23 Nurse Call and Code Blue Systems.pdf PDF
T-501_2023.01.06.pdf PDF
PA System Equipment Cut Sheets.pdf PDF
620-20-106 13CD RFI Responses.pdf PDF
AE102C_2023.01.06.pdf PDF
AE304_2023.01.06.pdf PDF
CCTV Video Equipment Cut Sheets.pdf PDF
36C24223B0004 0002 13CD Amendment 0002.pdf PDF
AE303_2023.01.06.pdf PDF
28 13 00 Physical Access Control System.pdf PDF
28 23 00 Video Surveilance.pdf PDF
Plumbing Cut Sheets.pdf PDF
36C24223B0004 Amendment 0001.pdf PDF
13CD Specs 1of2.pdf PDF
13CD Narrative 2of2.pdf PDF
13CD Narrative 1of2.pdf PDF
13CD Specs 2of2.pdf PDF
006_Fire Protection.zip ZIP file
005_Plumb.zip ZIP file
36C24223B0004_1.docx DOCX document
Wage Determination - Westchester County NY.pdf PDF
001A_Arch.zip ZIP file
003_Struct.zip ZIP file
007_Elec.zip ZIP file
001B_Arch.zip ZIP file
FAR 52.225-2 BUY AMERICAN CERTIFICATE.docx DOCX document
002_Hazard.zip ZIP file
004_Mech.zip ZIP file
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

T

R Transformer to be located in IT or Electrical Closet.

RCVC Dial(s) to be located as per Clients discretion.

Classic

Audio & Controls

______ OF ______

SHEET

DRAWN BY: SCALE: DATE:

REVISION

Drawing Size: 24x36 (D-Size) The information contained herein is proprietary to Lencore Acoustics LLC and copyright protected. No part of these documents shall be reused for any extensions of the project or any other project without the written consent of Lencore Acoustics. These are reference drawings not to be used for construction.

Wiring Legend Description Blue/Black: RCVC RCVC Volume Control Red/Brown: Power (Main to Main and Main to Transformer) White/Black: Audio (between Main and Secondary)

Green/Black: Paging/Music

White/Black/Red: RCVC to Remote Dials (18 gauge, 3-wire)

Linetype

Project Number:

UP-FIRING

UNIVERSAL

SPEAKER

TRANSFORMER

REMOTE VOLUME

CONTRL WALL DIAL

TELEPHONE

ACCESS MODULE

REMOTE VOLUME

CONTROL WITH

ON/OFF SWITCH

AMPLIFIER

PROGRAMMABLE

TIMER

ZONE SWITCH

No. DATE REVISION BY

AREA OF COVERAGE

DEPICTED (SQ. FT):

839 New York Ave, Suite 21 Huntington, NY 11743

(516) 682-9292 www.lencore.com

DescriptionQty. Sym. DescriptionQty. Sym.

DescriptionQty. Sym. DescriptionQty. Sym.

Speakers

NOT IN CONTRACT:

(PT) -

PAINTED

Speaker Modifications

(TB) -

TILE BRIDGE

DOWN-FIRING

UNIVERSAL

SPEAKER

UP-FIRING

NON-UNIVERSAL

SPEAKER

DOWN-FIRING

NON-UNIVERSAL

SPEAKER

CEILING PLATE

SPEAKER

SPEAKER

DECORATIVE

SWIVEL MOUNT

PAGING HORN

MAIN UP-FIRING

UNIVERSAL

MAIN

DOWN-FIRING

UNIVERSAL

SECONDARY

UP-FIRING

UNIVERSAL

SECONDARY

DOWN-FIRING

UNIVERSAL

MAIN UP-FIRING

NON-UNIVERSAL

MAIN

DOWN-FIRING

NON-UNIVERSAL

SECONDARY

UP-FIRING

NON-UNIVERSAL

SECONDARY

DOWN-FIRING

NON-UNIVERSAL

MAIN

CEILING PLATE

SECONDARY

CEILING PLATE

MAIN

SWIVEL MOUNT

SECONDARY

DECORATIVE

SWIVEL MOUNT

RCVC

UP-FIRING

UNIVERSAL

RCVC

DOWN-FIRING

UNIVERSAL

RCVC

UP-FIRING

NON-UNIVERSAL

RCVC

DOWN-FIRING

NON-UNIVERSAL

RCVC

CEILING PLATE

RCVC

SWIVEL MOUNT

CP

SM

M

S

M

S

M

S

M

S

M

S

T

R

R

R

R

R

M

S

R

R

TAMB

LOF

AMP

TMR

BGS

ITEM

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

VA Medical Center

2nd Floor

Hallways

2094 Albany Post Road Montrose, NY 10548

27351

SS 1/8"= 1'-0" 10/27/2021

1 1

TUNING NOTES FOR MASKING AND PAGING

1. Tuning Masking: measure 4' AFF, 47-48 dBA in Open Office and 45-46 dBA in Closed Office.

2. Tuning Paging: measure over the ambient background sound 10 dB in Private areas and 15 dB in Public areas.

1. This is not a construction drawing. This represents a proposed masking layout. Verification of unit placement prior to final installation may be required.

2. Placement of transformer and other head end equipment are depicted at suggested locations and may be relocated to other electrical, IT or communications closets within close proximity as needed or required.

3. Number of Lencore Sound Masking Units that are controlled by a single RCVC shall not exceed 150.

4. Maximum transformer loading is as follows:

· Without Paging: 78 Sound Masking Units per 95VA transformer, 33 per 40VA transformer

· With Paging: 33 Sound Masking Units per 95VA transformer, 16 per 40VA transformer.

5. Use 2 conductor plenum rated 18 AWG cable for power hook-up from transformer to either a RCVC or the first main unit if no RCVC is used.

6. Use non-shielded 6 conductor plenum rated 18 AWG cable for hook-up of RCVC to Main unit and Main to Main. Wire scheme is as follows:

· Brown and Red are used for Power

· Black is Common

· Blue is for RCVC

· Green is for Paging

IMPORTANT: Do NOT connect White wire between Main units or between RCVCs and Main. White wire is solely for hook-up of secondary units.

7. Use 2 conductor plenum rated 18 AWG cable for hook-up of Main units to Secondary units (White and Black wire).

8. Use 3 conductor plenum rated 18 AWG cable for hook-up of RCVC's Remote Plate & Knob to RCVC Speaker.

9. 16-18 volt step-down transformer requires power from 120 volt/20 amp circuit outlet*.

*Four (4) 40T-16 models can be attached to a standard 4" junction box. One (1) 95T-16 model can be attached to a standard 4" square junction box.

10. Please refer to Lencore Classic™ Installation Manual for complete instructions.

AutoCAD SHX Text *Full sized installation drawing will be e-mailed at time of order where channels will be identified.

AutoCAD SHX Text

GENERAL NOTES:

File details come from the government source that posted it. Updated .