This document package includes construction drawings and a federal contract solicitation. The drawings depict window schedule details, door frame details, and wall construction details for renovating Building 13CD at the Montrose VA Medical Center in Montrose, New York. The solicitation seeks offers to renovate Building 13CD for residential substance abuse programs. The Department of Veterans Affairs Veterans Health Administration VISN 2 will award a firm fixed-price contract to provide construction services including window replacements, door frame installations, and wall renovations according to the specifications. The contractor must complete all work by September 30, 2023.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OPENING TYPES
NOTES:
1. REFER TO SPECIFICATIONS FOR LOUVER TYPES LP1 AND LP2.
2. SEE SHEET AE903 FOR ADDITIONAL LOUVER DETAILS
LP1 LP2
6'
0"
3' - 6"
2' - 6"
1'
6"
W3W2W1
NOTES:
1. WINDOW AND LOUVER DIMENSIONS AREA NOMINAL. CONTRACTOR
SHALL FIELD MEASURE ALL OPENINGS AND MAKE NECESSARY
ADJUSTMENTS TO ACCOMMODATE INSTALLATION TOLERANCES TO
ENSURE ITEMS FIT PROPERLY WITHIN EXISTING CONDITIONS.
A8
AE303
SIM
A8
AE303
SIM
3'
3" 2"
A S
S C
H E
D U
LE
D
2"
2"
AS SCHEDULED
2"
LG2
A8
AE303
SIM
A8
AE303
SIM
2" 6' - 2"
2"
2"
3'
0"
3'
2"
LG2LG2 LG2
METAL STUD
PARTITION, SEE PLAN
FOR TYPE
TRANSACTION
WINDOW FRAME
METAL STUD
PARTITION, SEE PLAN
FOR TYPE.
GLAZING AS
SPECIFIED
CASING BEAD
EACH SIDE
A S
S C
H E
D U
LE
D
A S
S C
H E
D U
LE
D
MAX.
4"
SEALANT
STAINLESS STEEL
SHELF & ANGLE
BRACKETS AS
REQUIRED. 24" OC
MAX SPACING
HEAD
CONTINUOUS
SHEET METAL
CLOSURE
SHAPED WOOD
BACKING
LEDGER
SEALANT JOINT
BOTH SIDES
LEVEL 16 GA
STUD TRACK
DOOR AS
SCHEDULED
2"
SEALANT ALL AROUND
METAL STUD PARTITION -
SEE FLOOR PLAN FOR
TYPE
HEADER CONDITION @
OPENINGS OVER 4'-0"
METAL RUNNER
DOOR AS SCHEDULED
DOOR AS SCHEDULEDMETAL STUD
PARTITION - SEE
FLOOR PLAN FOR
TYPE
WIDTH
AS SCHEDULED
A
HEAD
B
JAMB
2"
6"
2"
W
ID
T H
A S
S C
H E
D U
LE
D
SEALANT
DOUBLE STUD
AT JAMB
SEALANT
F HG NV
6" 4"
DOOR MODIFICATIONS:
AC ACCESS CONTROL DEVICE
ADO AUTOMATIC DOOR OPERATOR
DEML DELAYED EGRESS MAGNETIC LOCK
DEPH DELAYED EGRESS PANIC EXIT DEVICE
DPS DOOR POSITION SWITCH
EL ELECTRIC LOCK OR ELECTRIC LEVER EXIT DEVICE
ELR ELECTRIC LATCH RETRACTION EXIT DEVICE
T.
O
. G
LA
S S
S
TO
P
3'
6" M
A X
T.
O
. G
LA
S S
S
TO
P
3'
6" M
A X
2'
2"
9"
DOOR TYPES
AS SCHED.
A S
S C
H E
D
A S
S C
H E
D
6" 6"
AS SCHED. AS SCHED.
A S
S C
H E
D
NOTE: (UNLESS OTHERWISE NOTED)
1. ALL GLASS IN INTERIOR DOORS TO BE 1/4"
TEMPERED GLASS.
2. GLASS IN SMOKE BARRIER DOORS TO BE FG1.
DOOR MODIFICATIONS:
EMCH ELECTRIC-MECHANICAL CLOSER-HOLDER
ES ELECTRIC STRIKE
FR#1 FIRE RATED GLAZING
H ELECTRIC HOLD
L LOUVER
LP LIGHT PROOF LOUVER
M MECH. SEAL FOR LIGHT PROOF & SOUND
DOOR MODIFICATIONS:
MHO MAGNETIC HOLD OPEN
ML MAGNETIC LOCK
PB PUSH-BUTTON COMBINATION LOCK
REX REQUEST TO EXIT SWITCH
RR REMOTE RELEASE BUTTON
U UNDER CUT 1"
FWSS
(FULL WOOD SINGLE SLIDER)
4"
/2
R O
U G
H O
P E
N
IN
G
R O
F
IN
. F
LO
O R
T O
S T
E E
L S
T U
D
/2
C
LE
A R
O P
E N
IN
G
C
O
/2
O V
E R
A
LL
O
A
3/ 8"
/4
D O
O R
L E
A F
D
L)
F F
T O
C L
O F
P U
LL 85
/2
N E
T F
R A
M E
37 1/4"
43 1/4"
DOOR LEAF
2 1/2"
11/16"
82" VALANCE
80 5/8" CARRIAGE TRACK 11/16"
36 1/2" (RO)
42 1/2" (RO)
FG
5" 5"
AS SCHED.
A S
S C
H E
D
5"
T.
O
. G
LA
S S
S
TO
P
"CD
A S
S C
H E
D
AS SCHED.
2" A
S S
C H
E D
U
LE
D 2"
3'
0"
2"
AS SCHEDULED
2"
A11
AE303
SIM
LG1 LG1
2" AS SCHED. 2"
2" A
S S
C H
E D
U
LE
D
FRAME TYPES
/2
R O
U G
H O
P E
N
IN
G
R O
F
IN
. F
LO
O R
T O
S T
E E
L S
T U
D
/2
C
LE
A R
O P
E N
IN
G
C
O
/2
O V
E R
A
LL
O
A
/2
N E
T F
R A
M E
11/16"
82" VALANCE
80 5/8" CARRIAGE TRACK 11/16"
4"
2" 2"
A S
S C
H E
D U
LE
D
4"
2" AS SCHED. 2"
SEE DETAIL AE303 G16 FOR
DOUBLE EGRESS
6" D
O O
R S
TO
P
2"1' - 6"2"
AS SCHED.
3' - 0"2"
2" A
S S
C H
E D
U
LE
D 4"
LG2
5"
5"
PLUS 1"
PARTITION WIDTH
GLAZING AS
SPECIFIED
HM FRAME
5/8" GWB
A
HEAD
B
JAMB
C
SILL
SEE PARTITION TYPE
2" 2"
2"
A S
S C
H E
D U
LE
D
S E
E F
R A
M E
E
LE
V A
TI
O
N
MET STUD FRAMING
6"
DOOR AS
SCHEDULE
GLAZING AS SPECIFIED
GLAZING AS
SPECIFIED
5/8" GWB
DOOR AS SCHEDULE
WHERE OCCURS
A
HEAD
B
JAMB
C
SILL
SEE PARTITION TYPE
FINISH FLOOR
4" 2"
2"
02 - SECOND FLOOR 13 CD
23' - 5"
NEW WALL AND SILL
FINISH. TYPICAL ALL
EXTERIOR WALL.
GRID
NEW INSULATED GLASS
UNIT IN EXISTING SASH TO
REPLACE INFILL PANEL /
UNITS TO COMPLY WITH
EPACT 2005 ENERGY
REQUIREMENTS.
EXISTING GLASS AND SASH
TO REMAIN. PROTECT
DURING CONSTRUCTION.
1" THICK SOLID
SURFACE SILL W/
SEALANT
G13
AE303
IG1
V E
R
IF
Y E
X
IS
TI
N
G
S C
H E
D U
LE
H
E
IG
H T
VERIFY EXISTING
SCHED WIDTH
E#, TYP, EXCEPT
RM 204
A
HEAD
B
JAMB
METAL RUNNER
SEALANT
DOOR AS SCHH
T
A S
S C
H 2"
6"
DOOR AS SCH
HM FRAME, GROUT
JAMBS AS SHOWN
DOUBLE STUD AT
JAMB
WIDTH AS SCH
1 1/2"
2 3/4"
6"
METAL STUD
PARTITION - SEE
FLOOR PLAN FOR TYPE
METAL STUD PARTITION -
SEE FLOOR PLAN FOR
TYPE
HEADER CONDITION @
OPENINGS OVER 4'-0"
SEALANT
VERIFY EXISTING
SCHED WIDTH
V E
R
IF
Y E
X
IS
TI
N
G
S C
H E
D H
E
IG
H T
WINDOWS AT
PATIENT BED
G10
AE303
IG2
02 - SECOND FLOOR 13 CD
23' - 5"
NEW WALL FINISH.
TYPICAL ALL EXTERIOR
WALL.
GRID
NEW IG2 PANEL IN NEW
FRAME
EXISTING WINDOW HEADER.
FIELD VERIFY CONDITION
EXISTING WINDOW SILL.
FIELD VERIFY CONDITION
INTEGRATED THUMB
TURN BLIND CONTROL
1" THICK SOLID
SURFACE SILL W/
SEALANT
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:
/8
/4
/8
/2
/4
-1
/2
FIRE PROTECTION:
STANTON ENGINEERING
10280 Old Columbia Rd. Ste. 275 Columbia, MD 21046 410-290-9301
HEALTHCARE PLANNER:
LEO A. DALY
730 2nd Ave. South, Ste. 1300 Minneapolis, MN 55402 612-752-8734
ARCHITECT:
CB DESIGN GROUP
421 KING STREET
SUITE 301
ALEXANDRIA, VA 22314
703-772-4213
PROFESSIONAL SEAL:
FDR VA Medical Center 2094 Albany Post Road Montrose, NY 10548-1454
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
MEP/STRUCTURE:
RAYMOND ENGINEERING
1224 Royal Drive Conyers, GA 30094 770-483-9592 x 110
COST ESTIMATION:
OCMI
6110 Executive Blvd. Ste. 440 Rockville, MD 20852 202-450-3843
01/06/2023
620-20-106
AADAB
RENOVATE BLDG 13CD FOR
RESIDENTIAL SUBSTANCE ABUSE
100% WORKING DRAWINGS
SUBMISSION
WINDOW SCHEDULE AND OPENING
DETAILS
AE303
-2
-1
A E
/2
/2
.p d f
3" = 1'-0"A11
DETAIL - TRANSACTION WINDOW, W1
3" = 1'-0"A16
DETAIL - HM DOOR FRAME TYP
Window Schedule
MARK WIDTH HEIGHT FRAME MATERIAL PANEL MATERIAL DETAIL ROOOM NUMBER
W1 3' - 6" 4' - 2" ALUMINUM LG1 A11 / AE303 230
W2 3' - 0" 4' - 0" A8 / AE303 236
W3 6' - 6" 4' - 0" A8 / AE303 256
3" = 1'-0"A8
DETAIL - HM WINDOW FRAME TYP
3" = 1'-0"A13
DETAIL - HM DOOR FRAME AND SIDELIGHT
1/2" = 1'-0"G13
WINDOW REPLACEMENT DETAIL - TYP
3" = 1'-0"G16
DETAIL - DOUBLE EGRESS HM DOOR FRAME
1/2" = 1'-0"G10
WINDOW REPLACEMENT DETAIL RM 204
HOLLOW METAL
HOLLOW METAL
LG2
LG2
REVISION SCHEDULE
# DESCRIPTION DATE
1 PRE-BID RFI 01/06/2023
| Sheets |
| AE303 - WINDOW SCHEDULE AND OPENING DETAILS |