7. CD103 Existing Features and Demolition Plan C.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24222B0037
About this file
This document includes an existing features and demolition plan drawing and related federal contract opportunity solicitation. The drawing depicts existing site features at a VA medical center campus including utilities, structures, vegetation and topographical information. It identifies various site elements that are to be removed or cleared as part of a contract to address groundwater issues at Building 30. The solicitation seeks bids for a contract to mitigate groundwater and support demolition work in accordance with the specifications in the drawing. Relevant details include the soliciting agency is the Department of Veterans Affairs, Veterans Health Administration VISN 2 for work at the Batavia VA Medical Center in Batavia, New York. The contractor will be responsible for test pits, tree removal, stump grinding, debris removal and site stabilization.
View the file
Other files
Show 40 more
Latest 50 of 76 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4" C
.I.
G
AS
L
IN
E
4" C.I. GAS LINE
4" C.I. GAS LINE
E.O.P.
CHAINLINK FENCE
30"
TREE
30"
TREE
40"
TREE
25"
TREE
40"
TREE
24"
TREE
UNKNOWN
UTILITY
TH #14
D
STORM MH
RIM: 911.69
STS24" D.I.P.
D
STORM MH
RIM: 908.50
INV. IN: 895.06 (S)
INV. OUT: 894.86
STS
STS
STS24" D.I.P.
D
STORM MH
RIM: 901.51
INV. IN: 893.54 (S)
INV. OUT: 893.34
STS
STS
STS
STS
131' of 24" D.I.P. S=0.010
24" RCP
24"
TREE
30"
TREE
24"
TREE
903904 906907908909
903904
STORMWATER COLLECTION SYSTEM
POTENTIALLY NOT ACTIVE
36"
TREE
36"
TREE
36"
TREE
STUMP
WOODED AREA TO BE CLEARED
CHAINLINK
FENCE
4" C
.I.
G
AS
L
IN
E
4" C.I. GAS LINE
4" C.I. GAS LINE
E.O.P.
CHAINLINK FENCE
30"
TREE
30"
TREE
40"
TREE
25"
TREE
40"
TREE
24"
TREE
UNKNOWN
UTILITY
TH #14
D
STORM MH
RIM: 911.69
STS24" D.I.P.
D
STORM MH
RIM: 908.50
INV. IN: 895.06 (S)
INV. OUT: 894.86
STS
STS
STS24" D.I.P.
D
STORM MH
RIM: 901.51
INV. IN: 893.54 (S)
INV. OUT: 893.34
STS
STS
STS
STS
131' of 24" D.I.P. S=0.010
24" RCP
24"
TREE
30"
TREE
24"
TREE
903904 906907908909
903904
STORMWATER COLLECTION SYSTEM
POTENTIALLY NOT ACTIVE
36"
TREE
36"
TREE
36"
TREE
STUMP
WOODED AREA TO BE CLEARED
CHAINLINK
FENCE
LdLm A
LmAOnBVA HOSPITAL DR.
BLDG. 21
CONC. ROAD BASE
APPROXIMATE
LOCATION
40" TREE
24"
TREE
18"
TREE
24"
TREE
SEE SHEET CD104
SE
E
SH
EE
T C D1
SE
E
SH
EE
T C D1
RICHMOND AVE.
VA HOSPITAL DR.
MEMORIAL DR.
RED
FIE
LD
PK
WY.
PA
RK
R D.
VETERANSA
B
C D
SITE SYMBOL - DEMOLITION
EXISTING LAWN AREA TO BE REMOVED
AND RESTORED
SITE SYMBOL
TEST HOLE #TH#
TREES TO BE REMOVED AS PART OF THIS
CONTRACT, SEE TREE REMOVAL SCHEDULE
EXISTING TREELINE TO BE REMOVED
8/1/2022
Batavia VA Medical Center Batavia, NY
528A4-18-203
CHRIS GEARY PE# 099085
Schadler/Waldron Geary
811 OR 1-800-962-7962
Project Number
Building Number
Sheet Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date: Dwg. of
KEY MAP
1"=800'
SCALE: 1"=20'
40'20'0'
TEST HOLE RESULTS BY ENGINEER
TEST HOLE
NUMBER
DEPTH TO
UTILITY
(FEET)
UTILITY
PIPE
SIZE
(INCHES)
REMARKS
14 2.7 GAS 4
GAS LINE IS MARKED AS 30 INCH ON
AS-BUILT DRAWINGS. THE EXPOSED LINE
WAS A FOUR INCH GAS LINE.
IF TREE ROOTS ARE ENCOUNTERED DURING
EXCAVATION, THE CONTRACTOR SHALL CUT
DOWN TREE AND REMOVE THE STUMP AS
PART OF THIS CONTRACT. REFER TO TREE
REMOVAL SCHEDULE AS THERE ARE SIX (6)
ADDITIONAL TREES (47 THROUGH 52) TO BE
REMOVED AS PART OF THIS CONTRACT
GENERAL NOTES:
1. THE CONTRACTOR SHALL CONDUCT SIX (6) TEST PITS WITH THE COR WITNESSING TO
VERIFY EXISTING CONDITIONS. TEST PITS SHALL BE CONDUCTED AFTER COORDINATION
WITH VA COR AND INSPECTED BY THE VA COR FOR ACCEPTANCE. THE CONTRACTOR SHALL
PROVIDE A SUBMITTAL WITH DOCUMENTATION OF THE TEST PITS CONDUCTED.
2. REFER TO TREE REMOVAL SCHEDULE ON THIS DRAWING. AREA WHERE TREES REMOVED
SHALL BE PROMPTLY STABILIZED TO PREVENT SOIL EROSION AND METHODS OF
STABILIZATION SHALL BE SUBMITTED AS PER THE SOILD AND EROSION CONTROL PLAN
SUBMITTALS.
3. AS PER THE 010000 GENERAL REQUIREMENTS, THE CONTRACTOR SHALL REPORT ANY PRE-EXISTING
CONDITIONS TO VA COR PRIOR TO COMMENCEMENT OF WORK OR THE CONTRACTOR SHALL
RESUME RESPONSIBILITY OF ANY ISSUES DISCOVERED.
SITE SYMBOLS - GENERAL
BENCHMARK:
DRAWING BLOCK TITLE WITH GRAPHIC SCALE
(SHOWN HALF ACTUAL SIZE)
BRICK WALKWAY
PLAN
DIMENSION
A
SITE SYMBOLS - CONCRETE/MASONRY
SITE SYMBOLS - UTILITIES
NOTE:
VERTICAL TEXT INDICATES PROPOSED FEATURES (PROP.)
SLANTED TEXT INDICATES EXISTING FEATURES (EX.)
STORM SEWER LINE
UTILITY, UTILITY POLE (UP)
UTILITY, WATER MANHOLEW
UTILITY, ELECTRICAL MANHOLEE
SIGN
WATER LINE
EDGE OF PAVEMENT
CURB LINE
MINOR CONTOUR
MAJOR CONTOUR
SITE SYMBOLS - EXISTING
TREE
DRAINAGE CATCH BASIN
DETAIL NUMBER
DETAIL SHEET
SITE SYMBOLS - ABBREVIATIONS
ELECTRIC LINE
Ø DIAMETER
APPROX APPROXIMATELY
BLDG BUILDING
CIP CAST IRON PIPE
CO CLEANOUT
CONC CONCRETE
CS CURB STOP
DIP DUCTILE IRON PIPE
DS DOWN SPOUT
EB ELECTRIC BOX
ELEC ELECTRIC
EMH ELECTRIC MANHOLE
EHH ELECTRIC HANDHOLE
EOP EDGE OF PAVEMENT
FES FLARED END SECTION
GOVT GOVERNMENT
GV GAS VALVE
HDPE HIGH DENSITY POLY ETHYLENE
INSP INSPECTION
INV STORMWATER PIPE END
IP IRON PIN
LF LINEAR FEET
MH MANHOLE
N/F NOW OR FORMERLY
NRCS NATIONAL RESOURCE CONSERVATION SERVICE
PLCC PLAIN CEMENT CONCRETE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
RCP REINFORCED-CONCRETE PIPE
S'WALK SIDEWALK
SF SQUARE FEET
SAN CO SANITARY CLEANOUT
STMH STEAM MANHOLE
TELE TELEPHONE
TEMP TEMPORARY
TMH TELEPHONE MANHOLE
TH TEST HOLE
TYP TYPICAL
WMH WATER MANHOLE
Y/4" 4" WIDE YELLOW PAINT LINE
DRAINAGE MANHOLE (DMH)D
GAS VALVE
HYDRANT, FIRE (FH)
UTILITY, SANITARY MANHOLE - (SAN MH)S
WATER VALVE (WV)
COMMUNICATION LINE
FIBER OPTIC LINE
GAS LINE
SANITARY SEWER LINE
STS
STEAM LINE
TELEPHONE LINE
UNKNOWN LINE
CENTERLINE
CHAINLINK FENCE
X X METAL FENCE
NRCS SOIL LINE
VEGETATION
LAMP POST
LIGHT POST (LP)
BOLLARD
CONCRETE
APPROXIMATE PROPERTY LINE
E UTILITY, ELECTRICAL HANDHOLE
COMM
GAS
SAN
ST
REVISED PER CONFERENCE CALL ON MARCH 9, 2021
REVISED PER 60% DESIGN REVIEW LETTERS
REVISED PER 90% DESIGN REVIEW LETTERS
REVISED PER FONT ISSUE/LINE ISSUE
5/11/2021 9/10/2021 2/4/2022 7/26/2022
CD103
7 23
Existing Features And Demolition Plan 'C' Bid Documents For Construction
Improve Ground Water, Building 30
TREE REMOVAL NOTES:
A. THE LOCATION AND DIAMETER OF THE TREES SHOWN IN THE CHART, PROVIDED ON DRAWINGS CD-101
THROUGH CD-104, ARE AN APPROXIMATE LOCATION AND BASE SIZE. ALL OF THE TREES ON CAMPUS ARE MARKED WITH YELLOW TAGS AND THE CORRESPONDING NUMBER. BIDDERS SHALL VERIFY TREES ON
CAMPUS PRIOR TO BIDDING ON PROJECT.
B. TREES SHALL BE CUT DOWN, STUMPS AND ROOTS GROUND DOWN MINIMUM OF 6 INCHES BELOW SURFACE, ALL DEBRIS REMOVED FROM SITE (WOOD AND SAW DUST), PROVIDE 6 INCHES OF CLEAN AND SCREENED TOPSOIL, HYDROSEEDED AND WATER DAILY AS PER THIS CONTRACT (USING A WATER TRUCK).
SAWDUST SHALL NOT BE BURIED, ALL SAW DUST SHALL BE REMOVED FROM SITE AND INSPECTED BY VA COR PRIOR TO TOPSOIL. THESE REQUIREMENTS ARE FURTHER OUTLINED IN THE NOTES ON DRAWING
GI002.
C. GRIND STUMP, NO TREE TO CUT AT THIS LOCATION.
D. MISCELLANEOUS TREE(S) TO BE REMOVED DURING THE PROJECT IDENTIFIED BY THE VA COR. THE TREES
THAT SHALL BE REMOVED IN ADDITION TO WHAT IS IDENTIFIED ON THE DRAWINGS ARE UP TO 36 INCHES
IN DIAMETER AT THE BASE OF THE TREE.
TREE REMOVAL SCHEDULE
DRAWING ITEM #
BASE
DIAMETER
(INCHES)
NOTES
CD-103 20 40 A,B
CD-103 21 25 A,B
CD-103 22 30 A,B
CD-103 23 36 A,B
NA 47 36 A,B,D
NA 48 36 A,B,D
NA 49 36 A,B,D
NA 50 36 A,B,D
NA 51 36 A,B,D
NA 52 36 A,B,D
DURING EXCAVATION THE CONTRACTOR WILL
ENCOUNTER RELATIVELY ROCKY SOIL. THE
CONTRACTOR SHALL REMOVE ALL OF THE ROCKS
FROM THE CAMPUS THAT ARE EXCAVATED LARGER
THAN A SOFTBALL IN SIZE. THE ROCKS SHALL NOT BE
RE-BURIED WHERE THEY CAN DAMAGE THE FORCE
MAIN PIPE OR TWO (2) PVC CONDUITS.
THE WOODED AREA WHERE THE FORCE MAIN WATER PIPE IS RUNNING PAST THE MAINTAINED
TREE LINE SHALL BE CLEARED AS PART OF THIS CONTRACT APPROXIMATELY 5 FEET MINIMUM
TO THE LEFT AND TO THE RIGHT OF THE PATH FOR THE FORCE MAIN WATER PIPE. THE
CONTRACTOR MAY ELECT TO CLEAR ADDITIONAL AREA FOR THEIR EQUIPMENT AND WORKING
AREA AT THEIR EXPENSE. TREES THAT ARE CUT DOWN BEYOND THE 5 FEET MINIMUM AREA
TO THE LEFT AND RIGHT OF THE FORCE MAIN WATER PIPE DO NOT NEED TO HAVE THE STUMP
GROUND. NEW TOPSOIL IS NOT NEEDED IN THIS AREA ONLY HOWEVER THE GROUND SHALL
BE COMPLETELY BACKFILLED TO THE SAME LEVEL AS ITS ORIGINAL CONDITION TO PROTECT
THE PIPE FROM FREEZING AND TO RE-ESTABLISH VEGETATION GROWTH. THE EXISTING LAYER
OF TOPSOIL SHALL BE REPLACED IN THIS AREA TO RE-ESTABLISH VEGETATION GROWTH TO
PREVENT EROSION. ALL DEBRIS THAT IS CLEARED SUCH AS TREES, ROOTS, WEEDS, ROCKS
FROM EXCAVATION, ETC. SHALL BE REMOVED FROM THE CAMPUS AT CONTRACTOR EXPENSE
AutoCAD SHX Text 200'
AutoCAD SHX Text 100'
AutoCAD SHX Text 50'
AutoCAD SHX Text
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
TU