6. CD102 Existing Features and Demolition Plan B.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24222B0037
About this file
This document package includes an existing features and demolition plan drawing and details for a federal contract opportunity to improve groundwater mitigation at Building 30 on the Batavia VA Medical Center campus.
The drawing depicts existing site features to be removed or retained, including trees, pavement, fences and utilities. A test hole log provides soil data. Notes require the contractor to conduct test pits, stabilize soil after tree removal, and report any undiscovered conditions. A tree removal schedule specifies 18 trees of various diameters to be cut down, ground, and hauled off-site along with debris. Six additional trees may require removal if encountered during excavation of relatively rocky soil, which must also be removed from campus.
The related federal contract opportunity is solicitation number 36C24222B0037 to mitigate groundwater at Building 30 for the Department of Veterans Affairs Veterans Health Administration VISN 2. No other opportunity details are provided.
View the file
Other files
Show 40 more
Latest 50 of 76 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4" CI GAS LINE
CHAINLINK FENCE
TH #10 TH #11
TH #12
TH #13
30" TREE
30" TREE
24"
TREE
30"
TREE
24"
TREE
16"
TREE
36" TREE
24"
TREE
24"
TREE
18" TREE
24"
TREE
30" TREE
15" TREE32"
TREE
24"
TREE
BITUMINOUS PAVING
EDGE OF PAVEMENT
EDGE OF PAVEMENT
EDGE OF PAVEMENT
STS
12" RCP
24" TREE
LP
LP
BOLLARD
(TYP)
LAWN REMOVAL
LAWN REMOVAL
STUMP
24"
TREE
30"
TREE
10"
TREE
24"
TREE
28"
TREE
24"
TREE
36" TREE
12 13
9 10
20" TREE
4" CI GAS LINE
CHAINLINK FENCE
TH #10 TH #11
TH #12
TH #13
30" TREE
30" TREE
24"
TREE
30"
TREE
24"
TREE
16"
TREE
36" TREE
24"
TREE
24"
TREE
18" TREE
24"
TREE
30" TREE
15" TREE32"
TREE
24"
TREE
BITUMINOUS PAVING
EDGE OF PAVEMENT
EDGE OF PAVEMENT
EDGE OF PAVEMENT
STS
12" RCP
24" TREE
LP
LP
BOLLARD
(TYP)
LAWN REMOVAL
LAWN REMOVAL
STUMP
24"
TREE
30"
TREE
10"
TREE
24"
TREE
28"
TREE
24"
TREE
36" TREE
12 13
9 10
20" TREE
LmA OnB LmA
OnB
VA HOSPITAL DR.
LANDS N/F
CITY OF BATAVIA
159 PARK ROAD
CONC. ROAD BASE
APPROXIMATE
LOCATION
24"
TREE
24"
SE
E
SH
EE
T C D1
SE
E
SH
EE
T C D1
SEE SHEET CD104
RICHMOND AVE.
VA HOSPITAL DR.
MEMORIAL DR.
RED
FIE
LD
PK
WY.
PA
RK
R D.
VETERANSA
B
C D
SITE SYMBOL - DEMOLITION
EXISTING LAWN AREA TO BE REMOVED
AND RESTORED
SITE SYMBOL
TEST HOLE #TH#
TREES TO BE REMOVED AS PART OF THIS
CONTRACT, SEE TREE REMOVAL SCHEDULE
EXISTING TREELINE TO BE REMOVED
8/1/2022
Batavia VA Medical Center Batavia, NY
528A4-18-203
CHRIS GEARY PE# 099085
Schadler/Waldron Geary
811 OR 1-800-962-7962
Project Number
Building Number
Sheet Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date: Dwg. of
KEY MAP
1"=800'
SCALE: 1"=20'
40'20'0'
TEST HOLE RESULTS BY ENGINEER
TEST HOLE
NUMBER
DEPTH TO
UTILITY
(FEET)
UTILITY
PIPE
SIZE
(INCHES)
REMARKS
10 4.5 - -
PIECE OF REBAR FOUND AT FOUR FEET,
EXCAVATION CONTINUED TO 54 INCHES.
THERE ARE NO UTILITIES EXPECTED AND
THE GROUND PENETRATING RADAR PICKED
UP REBAR AND NOT A UTILITY.
11 4.5 - - NO UTILITIES FOUND, STOPPED
EXCAVATION AT 54".
12 4.5 - - NO UTILITIES FOUND, STOPPED
EXCAVATION AT 54".
13 4.5 - - NO UTILITIES FOUND, STOPPED
EXCAVATION AT 54".
GENERAL NOTES:
1. THE CONTRACTOR SHALL CONDUCT SIX (6) TEST PITS WITH THE COR WITNESSING TO
VERIFY EXISTING CONDITIONS. TEST PITS SHALL BE CONDUCTED AFTER COORDINATION
WITH VA COR AND INSPECTED BY THE VA COR FOR ACCEPTANCE. THE CONTRACTOR SHALL
PROVIDE A SUBMITTAL WITH DOCUMENTATION OF THE TEST PITS CONDUCTED.
2. REFER TO TREE REMOVAL SCHEDULE ON THIS DRAWING. AREA WHERE TREES REMOVED
SHALL BE PROMPTLY STABILIZED TO PREVENT SOIL EROSION AND METHODS OF
STABILIZATION SHALL BE SUBMITTED AS PER THE SOILD AND EROSION CONTROL PLAN
SUBMITTALS.
3. AS PER THE 010000 GENERAL REQUIREMENTS, THE CONTRACTOR SHALL REPORT ANY PRE-EXISTING
CONDITIONS TO VA COR PRIOR TO COMMENCEMENT OF WORK OR THE CONTRACTOR SHALL
RESUME RESPONSIBILITY OF ANY ISSUES DISCOVERED.
SITE SYMBOLS - GENERAL
BENCHMARK:
DRAWING BLOCK TITLE WITH GRAPHIC SCALE
(SHOWN HALF ACTUAL SIZE)
BRICK WALKWAY
PLAN
DIMENSION
A
SITE SYMBOLS - CONCRETE/MASONRY
SITE SYMBOLS - UTILITIES
NOTE:
VERTICAL TEXT INDICATES PROPOSED FEATURES (PROP.)
SLANTED TEXT INDICATES EXISTING FEATURES (EX.)
STORM SEWER LINE
UTILITY, UTILITY POLE (UP)
UTILITY, WATER MANHOLEW
UTILITY, ELECTRICAL MANHOLEE
SIGN
WATER LINE
EDGE OF PAVEMENT
CURB LINE
MINOR CONTOUR
MAJOR CONTOUR
SITE SYMBOLS - EXISTING
TREE
DRAINAGE CATCH BASIN
DETAIL NUMBER
DETAIL SHEET
SITE SYMBOLS - ABBREVIATIONS
ELECTRIC LINE
Ø DIAMETER
APPROX APPROXIMATELY
BLDG BUILDING
CIP CAST IRON PIPE
CO CLEANOUT
CONC CONCRETE
CS CURB STOP
DIP DUCTILE IRON PIPE
DS DOWN SPOUT
EB ELECTRIC BOX
ELEC ELECTRIC
EMH ELECTRIC MANHOLE
EHH ELECTRIC HANDHOLE
EOP EDGE OF PAVEMENT
FES FLARED END SECTION
GOVT GOVERNMENT
GV GAS VALVE
HDPE HIGH DENSITY POLY ETHYLENE
INSP INSPECTION
INV STORMWATER PIPE END
IP IRON PIN
LF LINEAR FEET
MH MANHOLE
N/F NOW OR FORMERLY
NRCS NATIONAL RESOURCE CONSERVATION SERVICE
PLCC PLAIN CEMENT CONCRETE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
RCP REINFORCED-CONCRETE PIPE
S'WALK SIDEWALK
SF SQUARE FEET
SAN CO SANITARY CLEANOUT
STMH STEAM MANHOLE
TELE TELEPHONE
TEMP TEMPORARY
TMH TELEPHONE MANHOLE
TH TEST HOLE
TYP TYPICAL
WMH WATER MANHOLE
Y/4" 4" WIDE YELLOW PAINT LINE
DRAINAGE MANHOLE (DMH)D
GAS VALVE
HYDRANT, FIRE (FH)
UTILITY, SANITARY MANHOLE - (SAN MH)S
WATER VALVE (WV)
COMMUNICATION LINE
FIBER OPTIC LINE
GAS LINE
SANITARY SEWER LINE
STS
STEAM LINE
TELEPHONE LINE
UNKNOWN LINE
CENTERLINE
CHAINLINK FENCE
X X METAL FENCE
NRCS SOIL LINE
VEGETATION
LAMP POST
LIGHT POST (LP)
BOLLARD
CONCRETE
APPROXIMATE PROPERTY LINE
E UTILITY, ELECTRICAL HANDHOLE
COMM
GAS
SAN
ST
REVISED PER CONFERENCE CALL ON MARCH 9, 2021
REVISED PER 60% DESIGN REVIEW LETTERS
REVISED PER 90% DESIGN REVIEW LETTERS
REVISED PER FONT ISSUE/LINE ISSUE
5/11/2021 9/10/2021 2/4/2022 7/26/2022
CD102
6 23
Improve Ground Water, Building 30
Existing Features And Demolition Plan 'B' Bid Documents For Construction
TREE REMOVAL NOTES:
A. THE LOCATION AND DIAMETER OF THE TREES SHOWN IN THE CHART, PROVIDED ON DRAWINGS CD-101
THROUGH CD-104, ARE AN APPROXIMATE LOCATION AND BASE SIZE. ALL OF THE TREES ON CAMPUS ARE MARKED WITH YELLOW TAGS AND THE CORRESPONDING NUMBER. BIDDERS SHALL VERIFY TREES ON
CAMPUS PRIOR TO BIDDING ON PROJECT.
B. TREES SHALL BE CUT DOWN, STUMPS AND ROOTS GROUND DOWN MINIMUM OF 6 INCHES BELOW SURFACE, ALL DEBRIS REMOVED FROM SITE (WOOD AND SAW DUST), PROVIDE 6 INCHES OF CLEAN AND SCREENED TOPSOIL, HYDROSEEDED AND WATER DAILY AS PER THIS CONTRACT (USING A WATER TRUCK).
SAWDUST SHALL NOT BE BURIED, ALL SAW DUST SHALL BE REMOVED FROM SITE AND INSPECTED BY VA COR PRIOR TO TOPSOIL. THESE REQUIREMENTS ARE FURTHER OUTLINED IN THE NOTES ON DRAWING
GI002.
C. GRIND STUMP, NO TREE TO CUT AT THIS LOCATION.
D. MISCELLANEOUS TREE(S) TO BE REMOVED DURING THE PROJECT IDENTIFIED BY THE VA COR. THE TREES
THAT SHALL BE REMOVED IN ADDITION TO WHAT IS IDENTIFIED ON THE DRAWINGS ARE UP TO 36 INCHES
IN DIAMETER AT THE BASE OF THE TREE.
TREE REMOVAL SCHEDULE
DRAWING ITEM #
BASE
DIAMETER
(INCHES)
NOTES
CD-102 2 24 A,B
CD-102 3 32 A,B
CD-102 4 15 A,B
CD-102 5 30 A,B
CD-102 6 24 A,B
CD-102 7 36 A,B
CD-102 8 24 A,B
CD-102 9 24 A,B
CD-102 10 24 A,B
CD-102 11 24 A,B
CD-102 12 28 A,B
CD-102 13 24 A,B
CD-102 14 10 A,B
CD-102 15 30 A,B
CD-102 16 24 A,B,C
CD-102 17 18 A,B
CD-102 18 20 A,B
CD-102 19 36 A,B
NA 47 36 A,B,D
NA 48 36 A,B,D
NA 49 36 A,B,D
NA 50 36 A,B,D
NA 51 36 A,B,D
NA 52 36 A,B,D
IF TREE ROOTS ARE ENCOUNTERED DURING
EXCAVATION, THE CONTRACTOR SHALL CUT
DOWN TREE AND REMOVE THE STUMP AS
PART OF THIS CONTRACT. REFER TO TREE
REMOVAL SCHEDULE AS THERE ARE SIX (6)
ADDITIONAL TREES (47 THROUGH 52) TO BE
REMOVED AS PART OF THIS CONTRACT
DURING EXCAVATION THE CONTRACTOR WILL
ENCOUNTER RELATIVELY ROCKY SOIL. THE
CONTRACTOR SHALL REMOVE ALL OF THE ROCKS
FROM THE CAMPUS THAT ARE EXCAVATED LARGER
THAN A SOFTBALL IN SIZE. THE ROCKS SHALL NOT BE
RE-BURIED WHERE THEY CAN DAMAGE THE FORCE
MAIN PIPE OR TWO (2) PVC CONDUITS.
AutoCAD SHX Text 200'
AutoCAD SHX Text 100'
AutoCAD SHX Text 50'
AutoCAD SHX Text
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
TU
File details come from the government source that posted it. Updated .