This document is an Installation and Operation Manual for the Eaton Powerware 9390 UPS (20-80 kVA) and 9390IT (20-40 kVA) system. It provides comprehensive technical guidance for installing and configuring the uninterruptible power supply system and its associated components.
The manual covers multiple installation procedures including Integrated Distribution Cabinet (IDC) installation, Integrated Accessory Cabinet (IAC) installation, UPS Sidecar wiring, and external and battery power wiring connections. It details single-feed and dual-feed system configurations, parallel system wiring, and connections to Uninterruptible Power Modules (UPMs). Critical safety information is emphasized throughout, including cautions regarding high-impedance ground sources, delta supply sources, and neutral conductor requirements. The installation process requires removal of internal safety shield panels to access terminal blocks and conduit landing plates, with specific step-by-step procedures for routing power cables, connecting input/output terminals, and installing battery cables. The manual also covers optional installations including Remote Emergency Power-off (REPO) switches, Powerware Hot Sync CAN Bridge Cards for parallel system control, Remote Monitor Panel II (RMP II), Relay Interface Module II (RIM II), and Supervisory Contact Module II (SCM II). An installation checklist is provided to verify completion of all hardware, cabling, and electrical connections, with notation that startup and operational checks must be performed by an authorized Eaton Customer Service Engineer. The document includes detailed wiring diagrams, terminal block locations, and interface connector specifications for comprehensive installation verification.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| UPS Eaton 9390 product info.pdf | ||
| UPS Manual Section II Operation.pdf | ||
| 36C24127Q0030_3.docx | DOCX document | |
| UPS Drawings and Other Info.pdf | ||
| UPS Eaton PowerWare Replacement Photos.docx | DOCX document | |
| UPS Guide Specification.pdf | ||
| 36C24127Q0030_2.docx | DOCX document | |
| 36C24127Q0030_1.docx | DOCX document | |
| Attachment B - Wage Determination No 2015-4019 rev 35.pdf | ||
| Attachment A - Eaton 93E UPS manufacturer cut sheets and site electrical drawings Start-Up.pdf | ||
| 36C24127Q0030.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .