Bangor - Arch.pdf

PDF 6 MB Posted

Attached to
Z1DZ--Bangor - Imaging Suite and Dental Xray Room Prep
Solicitation number
36C24124Q0806
Issued by

About this file

This is an architectural plan set for a VA Outpatient Clinic located at 35 State Hospital Drive in Bangor, ME. The drawings detail a single-story medical facility with a penthouse level, featuring multiple clinical departments including primary care, dental, imaging, mental health, and specialty care areas. The building is Type III B construction with a gross floor area of 32,062 square feet and is fully sprinklered per NFPA 13.

Key architectural details include a main entry canopy, exterior finishes of brick veneer and EIFS, interior finishes primarily consisting of vinyl composition tile and carpet flooring with painted walls and acoustical tile ceilings. The facility includes multiple exam rooms, treatment spaces, staff offices, waiting areas, and support spaces. The plan set includes life safety plans showing fire-rated walls and egress paths, reflected ceiling plans, exterior elevations, wall sections, millwork details, door and window schedules, and room finish schedules. Building systems shown include plumbing, mechanical, electrical, and fire protection layouts coordinated with the architectural plans.

View the file

Other files

File Type Posted
Bangor Dental XRay pre-bid sign in sheet.pdf PDF
36C24124Q0806_2.docx DOCX document
Bangor 3D Shielding Plan.pdf PDF
Bangor - Elec.zip ZIP file
Bangor - Struct.pdf PDF
Drawing.pdf PDF
SOW - Bangor Imaging and Dental Xray Prep.pdf PDF
36C24124Q0806.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ENGINEERING CONSULTANTS

STRUCTURAL PLUMBING/MECHANICAL/ELECTRICAL/

FIRE PROTECTION

CIVIL

DATE:

CODE & BUILDING INFORMATION

W

EL

MA

N A

RC

HI

TE

CT

S, IN

C.

DESIGNER ARCHITECT CONTRACTOR

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

PHONE (262) 798.7000

FAX (262) 798.7001

E-MAIL welman@welmanarch.com

6737 West Washington Place, Suite 3245 Milwaukee, Wisconsin 53213 Phone: 414.453.0110 Fax: 414.453.0112 Website: www.summitsmith.com

35 State Hospital Drive Bangor, ME 04401

VA Outpatient Clinic

VA Outpatient Clinic

May 21, 2010 100% VA REVIEW PROJECT No: 28112

V A

O ut pa tie nt C lin ic

PR

O

JE

CT

N o:

M ay

1, .E0.01 SYMBOLS, ABBREVIATIONS & SHEET INDEX

.E0.10 SITE PLAN - ELECTRICAL

.EL2.1 FLOOR PLAN - FIRST FLOOR - LIGHTING

.EP2.1 FLOOR PLAN - FIRST FLOOR - POWER & FIRE ALARM

E2.2 FLOOR PLAN - ROOF - ELECTRICAL

E3.00 ENLARGED PLANS

E3.01 ENLARGED PLANS

E3.02 ENLARGED PLANS

E4.00 ONE LINE POWER DIAGRAM SYMBOLS & ABBREVIATIONS

E4.01 ONE LINE POWER DIAGRAM

E5.00 LIGHTING DETAILS

E5.10 POWER DETAILS

E5.11 POWER DETAILS

E5.12 POWER DETAILS

E5.20 FIRE ALARM DETAILS

E6.00 LIGHTING SCHEDULES

E6.01 LIGHTING SCHEDULES

E6.10 POWER SCHEDULES

E6.11 POWER SCHEDULES

E6.20 FIRE ALARM SCHEDULES

T0.01 SYMBOLS, ABBREVIATIONS & SHEET INDEX

T2.1 FLOOR PLAN - FIRST FLOOR - TECHNOLOGY

T3.00 ENLARGED PLANS

T3.01 ENLARGED PLANS

T4.00 TECHNOLOGY SCHEMATICS

T5.00 TECHNOLOGY DETAILS

T5.01 TECHNOLOGY DETAILS

T5.02 TECHNOLOGY DETAILS

T5.03 TECHNOLOGY DETAILS

T6.00 TECHNOLOGY SCHEDULES

S001 GENERAL NOTES

S002 GENERAL NOTES & SCHEDULES

S100 FOUNDATION PLAN

S200 LOW ROOF & PENTHOUSE FRAMING PLANS

S201 PENTHOUSE FLOOR FRAMING PLAN

S300 SMOKING SHELTER PLANS & DETAILS

S400 STRUCTURAL DETAILS

S401 STRUCTURAL DETAILS

S402 STRUCTURAL DETAILS

S403 STRUCTURAL DETAILS

P0.0 PLUMBING COVER SHEET & ENLARGED PLANS

P1.0 FOUNDATION PLUMBING PLAN

P1.1 FIRST FLOOR PLUMBING PLAN

P1.2 ROOF AND PENTHOUSE PLUMBING PLANS

P4.0 WASTE AND VENT ISOMETRICS

P4.1 WATER SUPPLY ISOMETRICS

P5.0 PLUMBING DETAILS AND SCHEDULES

FP0.0 FIRE PROTECTION COVER SHEET

FP1.1 FIRST FLOOR FIRE PROTECTION PLAN

FP5.0 FIRE PROECTION DETAILS AND SCHEDULES

H0.0 NOTES, SYMBOLS & ABBREVITIONS

H1.1 FIRST FLOOR PLAN - HVAC DUCTWORK

H1.2 FIRST FLOOR PLAN - HVAC PIPING

H1.3 PENTHOUSE PLAN &SECTIONS

H1.4 ROOF PLAN

H2.1 SCHEMATIC DIAGRAMS

H3.1 DETAILS

H3.2 DETAILS

H4.1 SCHEDULES

H4.2 SCHEDULES

T1.1 TITLE SHEET

.C101 NOTES

.V100 BOUNDARY PLAN

.V101 TOPOGRAPHIC PLAN

C201 REMOVAL & RELOCATION PLAN

C301 LAYOUT & UTILIES PLAN

C401 GRADING PLAN

C402 STORM DRAIN PROFILES

C403 WATER LINE PROFILES

C404 STATE STREET IMPROVEMENTS

C501 EROSION CONTROL PLAN

C601 LANDSCAPING PLAN

C701 DETAILS

C702 DETAILS

C703 DETAILS

C704 DETAILS

C705 DETAILS

L1.1 LEGEND & NOTES

LS.1 LIFE SAFTEY PLAN

A0.1 ARCHITECTURAL SITE PLAN

A1.1 FLOOR PLAN

A1.1C REFLECTED CEILING PLAN

A1.2 PENTHOUSE PLAN AND DETAILS

A1.3 ROOF PLAN

A2.1 EXTERIOR ELEVATIONS

A3.1 BUILDING SECTION & SMOKING SHELTER

A4.1 WALL SECTIONS & DETAILS

A4.2 CANOPY SECTIONS

A4.3 CANOPY SECTIONS & DETAILS

A5.1 DETAILS

A6.1 ENLARGED TOILET ROOM PLANS & ELEVATIONS

A6.2 TOILET ROOM ENLARGED PLANS AND ELEVATIONS

A7.1 INTERIOR ELEVATIONS

A7.2 INTERIOR ELEVATIONS

A7.3 INTERIOR ELEVATIONS

A8.1 DOOR SCHEDULE

A8.2 WINDOW SCHEDULE

A9.1 ROOM FINISH SCHEDULES

FLOOR AREA (GROSS):

Project Location

GOVERNING CODE:

OCCUPANCY CLASSIFICATION:

CONSTRUCTION TYPE:

ALLOWABLE HEIGHT:

ALLOWABLE AREA:

ALLOWABLE AREA INCREASE:

SPRINKLER SYSTEM:

EGRESS REQUIREMENTS:

LENGTH OF EXIT ACCESS TRAVEL DISTANCE

EGRESS WIDTH PER OCCUPANT

OCCUPANT LOAD

NUMBER OF REQUIRED EXITS

DEAD END PASSAGEWAY

COMMON PATH OF EGRESS TRAVEL

FIRE EXTINGUISHERS:

2006 International Building Code Business - Use Group B (Medical Clinic - Outpatient), Section 304.1

Type III B - Section 602.5, Table 601 4 Story, Table 503

19,000 sf / floor, Table 503 300% for Automatic Sprinkler System (+38,000sf), Section 506.3

Street Frontage, Section 506.2

(Automatic) Fully Sprinklered, per NFPA 13

B - 300' (w/ auto. sprink. system), Table 1016.1 Other Egress Components: .15" / occupant, Table 1005.1

B - 100 sf Gross, Table 1004.1.1

Floor Plan 39,343 sf / 100 sf = 394 Occupants

2, Table 1019.1 50'-0", Section 1017.3 (Exception #2)

100'-0", Section 1014.3 (Exception #1)

1 Per 3,000 sf (75'-0" Max. Travel Distance), per NFPA

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X

X X X X X X X X X X

X X X X X

X X X X X X X X X X X X X X X X

X X X X X X

X X X X

X X X X X X X X X X

X X X X X X X X X X X

X X X X X X

X X X X X X X

X X X X X X X X X X

X X X X X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X X

X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

X X

.19

.20

IS

SU

ES

RE

VI

SI

ON

S

.26

.20

03.19.2010 FTG/FND SUBMITTAL

03.26.2010 Design Development Review I & II

VICINITY MAPINDEX OF DRAWINGS

FIRST FLOOR 32,062

04.02.2010 75% VA Review

.02

.20

.19

.20

.26

.20

.02

.20

.19

.20

.26

.20

.02

.20

04.16.2010 City Submittal

.16

.20

.16

.20

.16

.20

ELECTRICALMECHANICALSTRUCTURALARCHITECTURAL

05.21.2010 CB #1

.21

.20

.21

.20

.21

.20

.21

.20

.21

.20

.21

.20

REVISIONS

05.21.2010 100% VA Review

22 2

11 1

2 22

2 22

1 11 1

1 11 1

1 11 1 1 1 1 1

1 11 1 1 1 1 1 1 1 1 1

1 1

1 11

11 1

1 11 1

11 11

LIFE SAFTEY LEGEND

EX

IT

REFER TO SHEET L1.1 FOR PARTITION TYPES

1 HOUR FIRE WALL PARTITION TYPE R.1 OR S.1

2 HOUR FIRE WALL PARTITION TYPE R.4 OR S.2

EXIT ROUTE

NEW FIRE EXTINGUISHER CABINET

EXIT SIGN

EXTERIOR EXIT LOCATION

DOOR RATINGS

1 HOUR FIRE WALL 45 MIN

1 HOUR FIRE/SMOKE 20 MIN

COMPARTMENT WALL

2 HOUR FIRE WALL 90 MIN

B B

C C

D D

E E

F F

G G

H H

F.8'

5.8'

7.8'

E.8'

3.9

A

4.7 5.6 6.6 2.5'

1.5'

C.3'

C.5'

D.5'

0.5'

3.5'

1.3'

2.3'

D.4

C.4

6.8'

C.2

C.6

E.4

5.5

F.3

EXIT

EXIT

EXIT

EX

IT

EXIT

EXIT

E.6 E.6

4.6

AUDIO SOUND

BOOTH

AUDIO SOUND

BOOTH

AUDIO OFF.

PAT. TLT.

PHYS. OFFICE

PHYS. EXTEND

ST. TOILET

EXAM

AUDIO OFFICE

AUDIO OFFICE

CAMERA

DISPENS.

EXAM

MECH.

1408A

HYGIENE

ORAL EXAM

VISUAL FIELDS

EXAM-EYE

LANE

DENTAL

IMAGING

EXAM-EYE

LANE

PATIENT

TOILET

SOIL. SPD

CART

SEC./REC.

ORAL EXAM

ORAL EXAM

STORAGE

ORAL SURG.

CLEAN

INSTRUMENTS

GROUP

THERAPY

1306OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

1305 GROUP

THERAPY

DENTAL/

PROSTH. LAB

RECOV. RM.

OFFICE

HEALTH TECH

OFF. ADMIN

ASST.

PASSAGE

1416C

PASSAGE

1321A

PASSAGE

PASSAGE

1321B

UTIL/STG

WAITING

PATIENT TLT

PATIENT TLT

OFFICE

OFFICE

PASSAGE

1321C

PASSAGE

1416A

PASSAGE

1416B

PASSAGE

PASSAGE

PASSAGE

1521A

PASSAGE

1633D

CRASH CT.

PAT. TLT

EXAM

EXAM

EXAM

EXAM

SPECIALTY

WAITING

PASSAGE

1633C

STORAGE

CLEAN UTIL.

SOIL UTIL.

PHYS. OFF.

PHYS. EXTEND.

PHYS. OFFICE

EXAM

EXAM

EXAM

EXAM/GYN.

ST. TOILET

CLINIC

MANAGER

URG. CARE

OBSVER/TREAT

EXAM

READING

PHYS. OFFICE

IMAGING

PASSAGE

TECH. OFF.

ULTRASOUND

PROCEDURE

HAC.

PAT. TLT

MED RECORDS

EMS SUPPLY

STERILE / NON

STERILE STOR

VESTIBULE

1801 CL LIN.

SOIL LIN.

IT/BIO MED

INFECT WASTE

1811 CL REC. / BULK

STOR

MAS STOR.,

SPLY, EQ.

PASSAGE

MEN'S TLT.

1021COMP/PEN

TELEHEALTH

1103PATIENT

TOILET

1101C

HYDRO THER.

1101D

OFFICE, SOC.

WKR.

OFFICE NURSE

TREATMENT/EXERCISE

WAIT

OFFICE NURSE

OFFICE NURSE

VOL/ESCORT

WAIT

VESTIBULE

STOR.

1101B

PASSAGE

PASSAGE

1633A

NURSE

PASSAGE

STAFF TLT

PASSAGE

1633B

AUDIO SUPPLY

VESTIBULE

SOC. WKR.

OFFICE

OFFICE

PATIENT

TOILET

USC/TOILET

MEDS

BLOOD DRAW

BLOOD DRAW

CONSULT #2

STORAGE

1008A

LAB

HAZ STOR

1204A

P.T. WAIT

MEN'S TLT.

WOMEN'S TLT.

OPEN OFFICE

EXAM-EYE

LANE

EXAM-EYE

LANE

1509 OFFICE

PRIMARY CARE

WAITING

WOMEN'S TLT.

NURSE

CORRIDOR

PHARMACY /

TRANS

CONSULT #1

PASSAGE

1205A

NURSE

WAITING

AUDIO

OFFICE/TECH.

CONFERENCE/

CLASS/ MULTI

PURPOSE

TELE/D.F.

PASSAGE

VESTIBULE

PASSAGE

1024A

TELE/DATA

MEN'S LOCKER

WOMEN'S

LOCKER

MECH

ELECT.

1905B

DIST.

1905A

AUDIO OFF.

PT OFFICE

1101A

DILATE/

SUBWAIT

ROUTE

MAINE VET

OFFICE

1005A

MAINE VET

CONFERENCE

1005B

MAINE VET

SECRETARY

MAINE VET

STORAGE

1005C

MED RECORDS

MAS OFFICE

1018REGISTRATION

/ CHECK IN

INFORMATION

1007 CHECK OUT

EXAM

PRIMARY

CARE/XRAY

WAITING

IT / CL

1902A

DRESS

DRESS

STORAGE

1701SUB WAIT

EDUCATIONAL

CONF ROOM

TELEPHONE

ASSISTANCE

PROGRAM

STORAGE

MYHEVET

PASSAGE

1712A

HAC

PASSAGE

1023A

PASSAGE

1024B

PASSAGE

1024C

PASSAGE

1024D

PASSAGE

1024B

PASSAGE

1024C

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

LS.1

LIFE SAFTEY PLAN

VA

Outpatient

Clinic

03/19/2010

28112

SCALE: 1/8" = 1'-0"1 LIFE SAFETY PLAN

TRUE NORTH PLAN NORTH

TOWEL DISPENSERTD.CAB. CABINET

PLUMBINGPLBG.

ELECTRIC WATER COOLEREWC.

FUT.

FTG.

FIXT.

FHC.

FF. EL.

FEC.

FDV.

FDN.

EXT.

EXG.

FT.

FR.

FL.

FIN.

FH.

FE.

FD.

FA.

FOOT OR FEET

FIRE RETARDANT

FIRE HOSE CABINET

FINISH FLOOR ELEVATION

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER

FIRE DEPARTMENT VALVE

FIXTURE

FUTURE

FOOTING

FLOOR

FINISH

FIRE HYDRANT

FOUNDATION

FLOOR DRAIN

FIRE ALARM

EXTERIOR

EXISTING

EQPT. EQUIPMENT.

ROUGH OPENING

RIGHT HAND

REVISION

RESILIENT

REQUIRED

REINFORCED OR REINFORCING

REFRIGERATOR

REFERENCE

ROOF DRAIN

RO.

RM.

RH.

REV.

RES.

REQD.

REINF.

REFR.

REF.

RD.

RAD.

R.

ROOM

RADIUS

RISER

QUARRY TILE

PNEUMATIC TUBE STATION

PARTITION

PAINT (ED)

PLYWOOD

PLASTIC LAMINATE

QT.

PTS.

PTN.

PNT.

PT.

PR.

PLYWD.

PLAM.

POINT

PAIR

CLEANOUT, CHANGE ORDER

EMER.

ELEV.

ELEC.

DWG.

DW.

DIM.

DIAM.

DET.

DEPT.

DBL.

CW.

CTSK.

CORR.

CONTR.

CONT.

CONSTR.

CONC.

COL.

CO.

CNTR.

CMU.

CLO.

CLL.

CLG.

CIP.

CHBD.

CG.

CER.

CAL.

DR.

EL.

EQ.

EP.

EJ.

EA.

DS.

DN.

DF.

CT.

CH.

CJ.

CB.

ELECTRICAL PANEL

ELEVATION (FLOOR)

EXPANSION JOINT

DRINKING FOUNTAIN

COUNTERSUNK

CONTRACT (OR)

DOOR

EQUAL

EMERGENCY

ELEVATOR

ELECTRIC (AL)

EACH

DRAWING

DRYWALL

DOWNSPOUT

DOWN

DIMENSION

DIAMETER

DETAIL

DEPARTMENT

DOUBLE

CASEWORK

CERAMIC TILE

CORRIDOR

CONSTRUCTION

CONCRETE MASONRY UNIT

CONTRACT LIMIT LINE

CONTROL JOINT

CASE IN PLACE CONCRETE

CORNER GUARD

COAT HOOK

CONTINUOUS

CONCRETE

COLUMN

COUNTER

CLOSET

CEILING

CHALKBOARD

CERAMIC

CATCH BASIN

CALIPER

LKR.

LAV.

LAM.

LAB.

KOP.

LP.

LT.

LH.

LOW POINT

LIGHT

KNOCK OUT PANEL

LOCKER

LEFT HAND

LAVATORY

LAMINATE

LABORATORY

PLASTER

PORTLAND CEMENT PLASTER

PRECAST CONCRETE

PAVEMENT

OVERHEAD

OPPOSITE

OPENING

OUTSIDE DIAMETER

ON CENTER

OVERALL

NOT TO SCALE

NOMINAL

NUMBER

NOT IN CONTRACT

NURSE CALL

PAVT.

PLAS.

PCPL.

PCC.

OA.

OH

OPP.

OPG.

OD.

OC.

NTS.

NOM

NO.

N.I.C.

NC.

MILLWORK

METAL TOILET PARTITION

MATERIAL (S)

MOUNTED

METAL STUDS

MASONRY OPENING

MISCELLANEOUS

MINIMUM

MANHOLE

MANUFACTURE (R)

MECHANICAL

MEDICINE CABINET

MAXIMUM

MASONRY

MIRROR

MAX.

MISC.

MW.

MTP.

MTL.

MTD.

MS.

MO.

MIN.

MH.

MFR.

MET.

MECH.

MC.

METAL

MAS.

M.

SQUARE

PROPERTY LINE OR PLATE

PLUS OR MINUS+-

POUND OR NUMBER

DIAMETER/ROUND

CENTER LINE

YARD DRAIN

WAINSCOT

WOOD PRESERVATIVE

WITHOUT

WATER CLOSET

VENEER PLASTER

VINYL COMPOSITE TILE

VESTIBULE

VERTICAL

WSCT.

Y.D.

YD.

WT.

ANGLE

AT

AND

YARD

WEIGHT

WP.

W/O

WD.

W.C.

W/

VPLAS.

VIN.

VCT.

VEST.

VERT.

WOOD

WITH

VINYL

UNDERSIDE

UNLESS NOTED OTHERWISE

UNDERWRITER'S LABORATORIES

UNDERCOUNTER

TYPICAL

TOP OF WALL

TELEVISION

TREATED

TRASH RECEPTACLE

TOILET PAPER DISPENSER

TACKBOARD

TERRAZO

TEMPORARY

TELEPHONE CABINET

TEMP.

U/S

UNO.

U/C

TYP.

TW.

UL.

TV.

TRTD.

TPD.

TKBD.

TERR.

TR.

TELCABT

ABBREVIATIONS

BSMT.

BOT.

BLKG.

BLDG.

B&B

AUTO.

ARCH.

APPROX.

ALUM.

ALT.

AHU.

AFF.

ADJ.

ACT.

ACOUS.

AC.

BP.

BN.

BM.

AP.

BC.

AD

BORROWED LIGHT

BED PAN CABINET

BEAM OR BENCHMARK

BASEMENT

BOTTOM

BULLNOSE

BLOCKING

BUILDING

BOTTOM OF CURB

BALLED & BURLAPPED

ACCESS PANEL

AIR HANDLING UNIT

ABOVE FINISHED FLOOR

ACOUSTICAL TILE

AUTOMATIC

ARCHITECT

APPROXIMATE

ALUMINUM

ALTERNATE

ADJUSTABLE

AREA DRAIN

ACOUSTICAL

ACRES

BL.

JAN.

INSUL.

HW.

HVAC

HORIZ.

HDWD.

HDW.

GYP.

GC.

GALV.

GA.

JT.

INT.

ID.

HT.

HR.

HP.

HM.

HC.

HB.

GL.

GB.

INSIDE DIAMETER

AIR CONDITIONING

HEATING, VENTILATING,

HAND RAIL, HOUR

HOLLOW METAL

HOLLOW CORE

JOINT

JANITOR

INTERIOR

INSULATION

HEAD WALL

HEIGHT

HIGH POINT

HORIZONTAL

HARDWOOD

HARDWARE

HOSE BIBB

GENERAL CONTRACT (OR)

GRAB BAR, GROUND BOX

GAUGE OR GAGE

GYPSUM

GLASS

GALVANIZED

SHOWER RODSR.

TOP OF CURB

TOWEL BAR

TONGUE & GROOVE

SYMMETRICAL

STORAGE

STANDARD

STATION

STAINLESS STEEL

TC.

T&G

TB.

T.

SYM.

STO.

STL.

STD.

STA.

SS.

TREAD

STEEL

SQUARE YARD

SQUARE INCH

SQUARE FOOT

SPECIFICATION (S)

SANITARY NAPKIN DISPOSAL

SANITARY NAPKIN DISPENSER

SECTION

SHOWER SEAT

SOAP DISPENSER/DISH

SPECIMEN BOX

SIM.

SQYD.

SQIN.

SQFT.

SPEC.

SND.

SN.

SHT.

SHL.

SECT.

SC.

SE.

SB.

SIMILAR

SHEET

SHELF

CFS CLEAR FLOOR SPACE

MATERIAL INDICATIONS

EARTH / COMPACTED FILL

FREE DRAINING AGGREGATE

CAST IN PLACE CONCRETE

PRECAST CONCRETE

BRICK

CONCRETE MASONRY UNIT

STRUCTURAL STEEL

WOOD (FRAMING)

WOOD (BLOCKING)

WOOD (FINISHED)

PLYWOOD

HARD BOARD

INSULATION (BATT)

INSULATION (RIGID)

INSULATION (SPRAYED)

NEW CONSTRUCTION

ACOUSTICAL CEILING TILE

GYPSUM BOARD

PARTICLE BOARD

EXISTING CONSTRUCTION

E.F.I.S.

"x"X"y"

GFI

F

M

W

S

XXX.X

X

X

XXX

XXX

X

NEW SINK-

SIZE LISTED IS OUTSIDE

DIMENSION LEFT TO RIGHT x

FRONT

TO BACK

VOLUME CONTROL

J-BOX WITH 1" CONDUIT STUBBED

TO 6" ABOVE CEILING

THERMOSTAT - MOUNT AT 54" A.F.F.

UNLESS NOTED OTHERWISE

UNDER CABINET LIGHT

MATCH LINE

DIMMER SWITCH - MOUNT AT 42"

A.F.F. UNLESS NOTED OTHERWISE

3 WAY SWITCH - MOUNT AT 42" A.F.F.

UNLESS NOTED OTHERWISE

DOUBLE POLE SWITCH - MOUNT AT

42" A.F.F. UNLESS NOTED OTHERWISE

SINGLE POLE SWITCH - MOUNT AT

42" A.F.F. UNLESS NOTED OTHERWISE

DOUBLE DUPLEX RECEPTACLE -

MOUNT AT 18" A.F.F. UNLESS NOTED

OTHERWISE

X

X

X

X

X X

X

MATCH LINE

XX-X

DETAIL .

SHEET NUMBER

ELEVATION(S)

SHEET NUMBER

ROOM NAME

ROOM NUMBER

WALL TYPES

NEW COLUMN LINE

DOOR NUMBER

FLOOR DRAIN

EXISTING COLUMN LINE

EXIT LIGHT.

GROUND FAULT INTERRUPTING

DUPLEX RECEPTACLE - MOUNT AT 6"

ABOVE BACK SPLASH OR

COUNTERTOP UNLESS NOTED

OTHERWISE

DUPLEX RECEPTACLE - MOUNT AT

18" A.F.F. UNLESS NOTED OTHERWISE

F.D.

SPEAKER

INTERCOM

SPECIAL ELECTRICAL RECEPTACLE

DEDICATED FAX LINE - MOUNT AT

18" A.F.F. UNLESS NOTED OTHERWISE

MULTIPLE OUTLET DATA

RECEPTACLE - MOUNT AT 18" A.F.F.

UNLESS NOTED OTHERWISE

WALL MOUNTED TELEPHONE -

MOUNT AT 54" A.F.F. UNLESS NOTED

OTHERWISE

DEDICATED MODEM LINE - MOUNT

AT 18" A.F.F. UNLESS NOTED

OTHERWISE

TELEPHONE - MOUNT AT 18" A.F.F.

UNLESS NOTED OTHERWISE

RECESSED FLUSH FLOOR MOUNTED

POWER, TELEPHONE, DATA

RECEPTACLE. COORDINATE WITH

FLOOR MATERIAL

RECESSED FLUSH FLOOR MOUNTED

DUPLEX RECEPTACLE. COORDINATE

WITH FLOOR MATERIAL

NEW PARTITION

LEAD-LINED WALLS - COORDINATE

REQUIREMENTS W/ PHYSICIST

REPORT

NEW DOOR AND DOOR FRAME

TENANT /OWNER PROVIDED

FURNITURE/EQUIPMENT

NEW 1 HOUR RATED PARTITION.

REFER TO WALL TYPE B.1

NEW 2 HOUR RATED PARTITION.

REFER TO WALL TYPE A.1

NEW 1 HOUR SMOKE TIGHT

PARTITION. REFER TO

WALL TYPE B.1

PROVIDE 16 GA. SHEET METAL

BANDING AS BLOCKING IN

PARTITION AS REQUIRED. VERIFY

LOCATION WITH FURN./EQUIP.

SUPPLIER

EXISTING DOOR AND DOOR FRAME TO

BE DEMOLISHED.

EXISTING PARTITION TO REMAIN

EXISTING DOOR TO REMAIN

EXISTING PARTITION TO BE

DEMOLISHED.

WINDOW TYPEX

BL - BORROWED LITE FRAME

TYPE

INTEGRATED WALL OUTLET / LIGHT

SWITCH - MOUNT AT 42" A.F.F.

UNLESS NOTED OTHERWISE

BL-X

FLOOR PLAN LEGEND

T

S

I

VC

S

S

S

X

SEE PLAN

SE

E

PL

AN

SOUND ATTENUATION BATT

INSULATION

AS REQ'D

METAL STUDS WITH TYPE "X" GWB

TO

STRUCTURE ABOVE.

MASTIC EACH SIDE

FINISHED FLOOR

FOR PARTITION PERPEND. TO

METAL

DECK, FILL FLUTES w/ FIRE SAFING

MATERIAL.

UNDERSIDE OF FLOOR OR ROOF DECK.

CONTINUOUS FIRE BARRIER

SEALANT

EACH SIDE.

CEILING (WHERE OCCURS) SEE

REFLECTED CEILING PLANS FOR

HEIGHT.

3" DEEP LEG TRACK

FOR PARTITION PERPEND. TO

METAL

DECK, FILL FLUTES w/ FIRE SAFING

MATERIAL.

UNDERSIDE OF FLOOR OR ROOF DECK.

CEILING (WHERE OCCURS) SEE

REFLECTED CEILING PLANS FOR

HEIGHT.

CONTINUOUS FIRE BARRIER

SEALANT

EACH SIDE.

SOUND ATTENUATION BATT

INSULATION

AS REQ'D

METAL STUDS WITH TYP "X" GWB TO

STRUCTURE ABOVE. (M. R. GWB

BEHIND

PLUMBING FIXTURES)

FINISHED FLOOR

MASTIC EACH SIDE

VARIES

3" DEEP LEG TRACK

6"

6"

4 7 /8"

4 7 /8"

4 7 /8"

7 1 /4"

7 1 /4"

4 7 /8"

4 7 /8"

4 7 /8"

7 1 /4"

7 1 /4"

2 1 /4"

2 1 /4"

3 1 /8"

3 1 /8"

VA

RI

ES

4 1 /4"

4 7 /8"

4 7 /8"

6 1 /8"

6 1 /8"

3 1 /8"

LATERAL BRACING AS REQ'D

UNDERSIDE OF FLOOR OR ROOF DECK.

3" DEEP LEG TRACK

3-1/2" SOUND ATTENUATION BATT

INSULATION 2'-0" EACH SIDE OF

PARTITION.

CEILING (WHERE OCCURS) SEE

REFLECTED CEILING PLANS FOR

HEIGHT.

SOUND ATTENUATION BATT

INSULATION

AS REQ'D

METAL STUDS

MASTIC EACH SIDE

FINISHED FLOOR

THROUGH CEILING PARTITIONB

B.1

3-5/8" METAL STUDS @ 16" O.C. 3-1/2" SOUND ATTENUATION BATT

INSULATION ONE LAYER 5/8" TYPE "X" GWB EACH SIDE TO 6" ABOVE

CEILING

B.2

3-5/8" METAL STUDS @ 16" O.C. ONE LAYER 5/8" TYPE "X" GWB EACH

SIDE

TO 6" ABOVE CEILING

ONE LAYER 5/8" TYPE "X" GWB ONE SIDE OF EXISTING METAL STUDS, TO

6'

ABOVE CEILING

6" METAL STUDS @ 16" O.C. 6" SOUND ATTENUATION BATT INSULATION

ONE

LAYER 5/8" TYPE "X" GWB EACH SIDE TO 6" ABOVE CEILING

6" METAL STUDS @ 16" O.C. ONE LAYER 5/8" TYPE "X" GWB EACH SIDE TO

6"

ABOVE CEILING

UL#:

STC:49

UL#:

STC:40

UL#:

STC:40

UL#:

STC:56

UL#:

STC:40

UL#:

STC:49

UL#:

STC:40

UL#:

STC:40

UL#:

STC:56

UL#:

STC:40

UL#:

STC:

UL#:

STC:

UL#:

STC:

UL#:

STC:

UL#:

STC:

B.3

B.4

B.5

FOR PARTITION PERPEND. TO

METAL

DECK, FILL FLUTES w/ FIRE SAFING

MATERIAL.

SOUND ATTENUATION BATT INSULATION

OR RIGID INSULATION AS REQUIRED -

SEE

DETAIL BELOW

CEILING (WHERE OCCURS) SEE

REFLECTED CEILING PLANS FOR

HEIGHT.

UNDERSIDE OF FLOOR OR ROOF DECK.

EXISTING PARTITION

FINISHED FLOOR

MASTIC EACH SIDE

METAL STUDS

FINISHED FLOOR

MASTIC EACH SIDE

METAL STUDS

SOUND ATTENUATION BATT

INSULATION

AS REQ'D

CEILING (WHERE OCCURS) SEE

REFLECTED CEILING PLANS FOR

HEIGHT.

SEALANT EACH SIDE

UNDERSIDE OF FLOOR OR ROOF DECK.

3" DEEP LEG TRACK

FULL HEIGHT PARTITIONC

C.1

3-5/8" METAL STUDS @ 16" O.C. 3-1/2" SOUND ATTENUATION BATT

INSULATION ONE LAYER 5/8" TYPE "X" GWB EACH SIDE TO

STRUCTURE

ABOVE

C.2

3-5/8" METAL STUDS @ 16" O.C. ONE LAYER 5/8" TYPE "X" GWB EACH

SIDE

TO STRUCTURE ABOVE

C.3

ONE LAYER 5/8" TYPE "X" GWB ONE SIDE OF EXISTING METAL STUDS,

TO

STRUCTURE ABOVE

C.4

6" METAL STUDS @ 16" O.C. 6" SOUND ATTENUATION BATT INSULATION

ONE

LAYER 5/8" TYPE "X" GWB EACH SIDE TO STRUCTURE ABOVE

C.5

6" METAL STUDS @ 16" O.C. ONE LAYER 5/8" TYPE "X" GWB EACH SIDE

TO

STRUCTURE ABOVE

3-5/8" METAL STUDS @ 16" O.C. 3-1/2" SOUND ATTENUATION BATT

INSULATION 4 MIL POLY VAPOR BARRIER ONE LAYER 5/8" TYPE "X" GWB

TO

STRUCTURE ABOVE

F.5

2-1/2" METAL STUDS @ 16" O.C. 4 MIL POLY VAPOR BARRIER ONE LAYER

5/8"

TYPE "X" GWB TO STRUCTURE ABOVE

F.4

2-1/2" METAL STUDS @ 16" O.C. 2" RIGID INSULATION 4 MIL POLY

VAPOR

BARRIER ONE LAYER 5/8" TYPE "X" GWB TO STRUCTURE ABOVE

F.3

1-5/8" METAL STUDS @ 16" O.C. 4 MIL POLY VAPOR BARRIER ONE LAYER

5/8"

TYPE "X" GWB TO STRUCTURE ABOVE

F.2

1-5/8" METAL STUDS @ 16" O.C. 1-1/2" RIGID INSULATION 4 MIL POLY

VAPOR

BARRIER ONE LAYER 5/8" TYPE "X" GWB TO STRUCTURE ABOVE

F.1

F FURRING

3-5/8" METAL STUDS @ 16" O.C. 3-1/2" SOUND ATTENUATION BATT

INSULATION ONE LAYER OF 5/8" TYPE "X" GWB TO STRUCTURE ABOVE (M. R.

GWB BEHIND PLUMBING FIXTURES)

P.1

P PLUMBING PARTITION RATED PARTITIONR

R.1

3-5/8" METAL STUDS @ 16" O.C. 3-1/2" SOUND ATTENUATION BATT

INSULATION ONE LAYER OF 5/8" TYPE "X" GWB EACH SIDE TO

STRUCTURE ABOVE

R.2

COMPLETION OF R.1 PARTITION

ONE LAYER OF 5/8" TYPE "X" GWB ON ONE SIDE OF EXISTING METAL

STUDS,

TO STRUCTURE ABOVE

R.3

3-5/8" METAL STUDS @ 16" O.C. WITH 3-1/2" SOUND ATTENUATION BATT

INSULATION TWO LAYERS OF 5/8" TYPE "X" GWB TO STRUCTURE ABOVE

ONE SIDE ONE LAYER 5/8" TYPE "X" GYP BOARD ON 1/2" RESILIENT 25

MSG

GALV. STEEL FURRING CHANNELS. ABOVE ONE SIDE

R.4

3-5/8" METAL STUDS @ 16" O.C. 3-1/2" SOUND ATTENUATION BATT

INSULATION TWO LAYERS OF 5/8" TYPE "X" GWB EACH SIDE TO

STRUCTURE

ABOVE

R.5

1-5/8" METAL STUDS @ 16" O.C. 1-1/2" SOUND ATTENUATION BATT

INSULATION ONE LAYER OF 3/4" TYPE "X" GWB EACH SIDE TO

STRUCTURE

ABOVE

1 HR

UL#: U419

STC:49

1 HR

UL#: U419

STC:49

1-1/2 HR

UL#: U452

STC: 58

2 HR

UL#: U411

STC:58

1 HR

UL#: U419

STC:

1 HR

UL#:U404

STC:61

5 3 /8"

UL#:

STC:49C.7

3-5/8" METAL STUDS @ 16" O.C. TO STRUCTURE ABOVE. PROVIDE 3-1/2" SOUND

ATTENUATION BATT INSULATION ONE LAYER 5/8" TYPE "X" GWB EACH SIDE TO

STRUCTURE ABOVE. PROVIDE 1/2" METAL SECURITY MESH OPPOSITE THE

SECURE ROOM SIDE TO STRUCTURE ABOVE.

SECURE ROOM SIDE

UNDERSIDE OF FLOOR OR ROOF DECK.

CEILING (WHERE OCCURS) FOR

CEILING HEIGHT, SEE REFLECTED

CEILING PLANS.

M

FINISHED FLOOR

CMU - SEE BELOW FOR SIZE

MASONRY PARTITION

UL#:

STC:

6 7 /8"

6" CONCRETE MASONRY UNIT WITH ONE

LAYER OF 5/8" TYPE "X" GWB EACH SIDE TO

STRUCTURE ABOVE

M.1

STC:

UL#:M.2

8" CONCRETE MASONRY UNIT

7 5 /8"

WALL / PARTITION TYPES REFER TO GENERAL NOTES 10 & 15 FOR ADDITIONAL REQUIREMENTS.

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

L1.1

LEGEND & NOTES

VA

Outpatient

Clinic

03/19/2010

28112

Y

H

D

RARE

NANTUCKET

SHADBUSH

LO

CATIO

N

RARE

NANTUCKET

SHADBUSH

LO

CATIO

N

RARE

NANTUCKET

SHADBUSH

LO

CATIO

N

30' HIGH FLAG POLE

WITH GROUND

MOUNTED UPLIGHTING

'-0

" M

IN

13'

- 6

" 13' - 6"

0"

0"

0"

9' - 0"

EXISTING BUILDING

THIS SHEET IS PROVIDED FOR REFERENCE ONLY. REFER TO

CIVIL DRAWINGS FOR SITE GRADING, PARKING LAYOUT,

UTILITIES, LANDSCAPING, DIMENSIONS, ETC. UTILITY ROUTES

& PARKING LAYOUTS MAY BE UPDATED PER CITY COMMENTS.

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

A0.1

ARCHITECTURAL SITE

PLAN

VA

Outpatient

Clinic

03/19/2010

28112

SCALE: 1" = 30'-0"1 ARCHITECTURAL SITE PLAN

TRUE NORTH PLAN NORTH

5402/5405

20AMPS

445 444

2 22

2 22

1 11 1

1 11 1

1 11 1 1 1 1 1

1 11 1 1 1 1 1 1 1 1 1

1 1

1 11

11 1

1 11 1

11 11

1 11

11 1

B B

C C

D D

E E

F F

G G

H H

F.8'

1010.2 1204.1

1C

.1

1101D.1

1B

.1

1203.1

0.1

1202.1

1201.1

1B

.1

1316.1

1317.1

1320.1

1314.1

1313.1

8.1

7.1

6.1

1312.1 1305.1

3.1

5.1

9.1

1318.1

1.1

1301.1

1302.1

1304.1

1409.1

1410.1

1411.1

1412.1

1414.1

5.1

3.1

1403.1

1406.1

8.1

1408A.1

1407.1

1405.1

1404.1

1401.1

1501.1

1502.1

1507.1

4.1

3.1

2.1

1506.1

1504.1

5.1

4.1

2.1

1.1

3.1

2.1

3.1

0.1

1500.2

1627.1

1631.1

1700.1

5.1

3.1

1619.1

1618.1

1617.1

1616.1

1615.1

1614.1

1609.1

1607.1

1605.1

1604.1

1710.1

0.1

1.1

1608.1

1629.1

1632.1

3.1

1606.1

2.1

1.1

1704.1

8.1

9.1

8.1

1809.1

1810.1

7.1

6.1

4.1

3.1

1905B.1

3.1

AUDIO SOUND

BOOTH

AUDIO SOUND

BOOTH

AUDIO OFF.

PAT. TLT.

PHYS. OFFICE

PHYS. EXTEND

ST. TOILET

EXAM

AUDIO OFFICE

AUDIO OFFICE

CAMERA

DISPENS.

EXAM

MECH.

1408A

HYGIENE

ORAL EXAM

VISUAL FIELDS

EXAM-EYE

LANE

DENTAL

IMAGING

EXAM-EYE

LANE

PATIENT

TOILET

SOIL. SPD

CART

SEC./REC.

ORAL EXAM

ORAL EXAM

STORAGE

ORAL SURG.

CLEAN

INSTRUMENTS

GROUP

THERAPY

1306OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

1305 GROUP

THERAPY

DENTAL/

PROSTH. LAB

RECOV. RM.

OFFICE

HEALTH TECH

OFF. ADMIN

ASST.

PASSAGE

1416C

PASSAGE

1321A

PASSAGE

PASSAGE

1321B

UTIL/STG

WAITING

PATIENT TLT

PATIENT TLT

OFFICE

OFFICE

PASSAGE

1321C

PASSAGE

1416A

PASSAGE

1416B

PASSAGE

PASSAGE

PASSAGE

1521A

PASSAGE

1633D

CRASH CT.

PAT. TLT

EXAM

EXAM

EXAM

EXAM

SPECIALTY

WAITING

PASSAGE

1633C

STORAGE

CLEAN UTIL.

SOIL UTIL.

PHYS. OFF.

PHYS. EXTEND.

PHYS. OFFICE

EXAM

EXAM

EXAM

EXAM/GYN.

ST. TOILET

CLINIC

MANAGER

URG. CARE

OBSVER/TREAT

EXAM

READING

PHYS. OFFICE

IMAGING

PASSAGE

TECH. OFF.

ULTRASOUND

PROCEDURE

HAC.

PAT. TLT

MED RECORDS

EMS SUPPLY

STERILE / NON

STERILE STOR

VESTIBULE

1801 CL LIN.

SOIL LIN.

IT/BIO MED

INFECT WASTE

1811 CL REC. / BULK

STOR

MAS STOR.,

SPLY, EQ.

PASSAGE

MEN'S TLT.

1021COMP/PEN

TELEHEALTH

PATIENT

TOILET

1101C

HYDRO THER.

1101D

OFFICE, SOC.

WKR.

OFFICE NURSE

TREATMENT/EXERCISE

WAIT

OFFICE NURSE

OFFICE NURSE

VOL/ESCORT

WAIT

VESTIBULE

STOR.

1101B

PASSAGE

PASSAGE

1633A

5.8'

7.8'

A2.1

A2.1

A2.1

A2.1

A4.2

NURSE

PASSAGE

1'

- 4

8"

0"

0"

8"

6"

8" 1'

- 4

1' - 4" 29' - 8" 30' - 0" 30' - 0" 30' - 2" 29' - 10" 29' - 8" 1' - 4"

1' - 4" 29' - 8" 30' - 0" 30' - 0" 30' - 2" 29' - 10" 29' - 8" 1' - 4"

1'

- 4

8"

0"

0"

2"

8"

1'

- 4

STAFF TLT

PASSAGE

1633B

AUDIO SUPPLY

50'

- 0

1' - 4"

23'

- 8

23'

- 8

1' - 4"

34'

- 0

VESTIBULE

AMBULANCE BAY

LOADING AREA

A4.3

4.1

3.1

1311.1

1309.1131 0.1

SOC. WKR.

OFFICE

OFFICE

6.2

PATIENT

TOILET

USC/TOILET

2.2

3.1

2.1

1.1

6.1

5.1

1628.1

MEDS

1630.1

6.1

BLOOD DRAW

BLOOD DRAW

CONSULT #2

STORAGE

1008A

LAB

HAZ STOR

1204A

P.T. WAIT

MEN'S TLT.

WOMEN'S TLT.

OPEN OFFICE

EXAM-EYE

LANE

EXAM-EYE

LANE

1509 OFFICE

PRIMARY CARE

WAITING

WOMEN'S TLT.

NURSE

5.1

E.8'

1' - 4"

23' - 10"

3.9

A

4.7 5.6 6.6 2.5'

1.5'

C.3'

C.5'

D.5'

7' - 6"

17' - 0" 0.5'

3.5'

15'

- 0

15'

- 0

1.3'

2.3'

8' - 9"

13'

- 1

0"

8' - 9"

18' - 0"12' - 6"17' - 4"9' - 0"

A4.1

A4.1

A4.1

A4.1

CORRIDOR

PHARMACY /

TRANS

CONSULT #1

PASSAGE

1205A

28' - 8" 1' - 4"

1' - 4"

1' - 4"

1204A.1

1.2

NURSE

WAITING

0"

0"

7'

- 0

0"

0"

0"

0"

0"

7'

- 0

7'

- 0

7'

- 0

6'

- 0

0"

12' - 5 1/2" 6' - 0" 13' - 7" 13' - 0"

0"

6"

8'

- 0

8' - 5" 12' - 10" 20' - 0"

14' - 8"

6'

- 5

3"

0" 7'

- 7

6'

- 5

4'

- 7

6' - 5" 11' - 9 1/2" 11' - 9 1/2" 6' - 5"

0" 6'

- 0

0"

0"

9 1 /2"

6'

- 5

9 1

/2"

9 1

/2" 6'

- 5

9 1 /2"

0"

5' - 10 1/2" 5' - 11"

2'

- 0

6' - 0"

11' - 10" 10' - 10" 12' - 9"

11' - 8" 9' - 0" 9' - 0" 9' - 0" 21' - 0" 35' - 2 1/2" 11' - 9 1/2" 12' - 5" 8' - 7"

6'

- 4

D.4

C.4

2"

2"

0"

0"

8"

0"

0"

0"

6.8'

6' - 5" 11' - 9 1/2" 11' - 9 1/2" 6' - 5" 11' - 9 1/2" 11' - 9 1/2" 6' - 5" 10' - 7" 6' - 5"

6'

- 5

8'

- 9 1/

2" 8'

- 9 1/

2" 6'

- 5

5'

- 9

1/ 2"

9'

- 0

1/ 2"

8'

- 5

1/ 2"

7" 6'

- 0

8'

- 0

11' - 9 1/2" 7' - 0" 12' - 0" 8' - 9 1/2" 8' - 9 1/2" 8' - 5" 5' - 5" 10' - 7"

2 1 /2"

0"

0 1

/2"

0"

0"

6'

- 0

6'

- 0

9'

- 8

3 1 /2"

3 1 /2"

6'

- 5

6'

- 0

9'

- 0

9'

- 0

0"

0" 6'

- 8

0"

0"

0"

0"

8"

5' - 5"

6' - 0" 6' - 0"

0" 4'

- 1 0"

7'

- 1

0 3 /8"

7"

1/

2"

5'

- 1

1 1 /2"

6'

- 0

5' - 0"

10' - 10" 10' - 10" 8' - 0" 8' - 0" 6' - 0"

5' - 5"

1" 3'

- 0

8' - 0"

7'

- 1

1"

0 1

/4"

5' - 5"

9' - 1 1/8" 2' - 0" 8' - 11 7/8" 1' - 10"

3'

- 0

135.00

3' - 0"

135.00

5'

- 8

6' - 8"

11' - 5 1/2"

11' - 10"

21'

- 3

8' - 5"

6' - 5"

11'

- 3

13'

- 4

1' - 4"

7' - 0"

7' - 0"

6' - 2"

25' - 4"

C.2

C.6

8'

- 0

0"

7'

- 0

2' - 0" 4' - 0" 15' - 8" 4' - 0" 27' - 4" 7' - 4" 37' - 8" 6' - 4"

1.1

4' - 0"

1' - 2" 10"

4' - 0"4' - 0"

1' - 0" 1' - 0"

4' - 0"2' - 0" 4' - 0" 8' - 0" 4' - 0" 8' - 0" 4' - 0"

1' - 0" 1' - 0"

4' - 0" 8' - 0" 4' - 0" 8' - 0" 4' - 0"

1' - 0" 1' - 0"

4' - 0" 8' - 0" 4' - 0" 8' - 0" 20' - 0"

2'

- 0

4'

- 0

8" 4'

- 0

5'

- 4

4'

- 0

2'

- 0

4'

- 0

8'

- 0

4'

- 0

8'

- 0

4'

- 0

2'

- 0

5'

- 8

4'

- 0

8'

- 0

4'

- 0

0"

1'

- 4

5 1 /2"

6'

- 5

12' - 11 1/2" 6' - 5" 8' - 7"

16' - 4" 23' - 0"

6' - 5"

6' - 5" 11' - 9 1/2" 11' - 9 1/2"

11' - 0" 9' - 6 1/2"

29' - 0"

6' - 4"

8.1

AUDIO

OFFICE/TECH.

6' - 8"

A4.2

A4.2

A4.2

A4.3

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

(TYP.)

VERIFY BOOTH SIZE

1 1 1 1 1 1 1 1 1

2 2 2

1000.3

1000.1

1.1

2.1

1020.1

0.2

1521A.1

1025.1

4'

- 0

8'

- 0

4'

- 0

"10

1'

- 2

4'

- 0

8'

- 0

4'

- 0

8'

- 0

4'

- 0

1'

- 0

1'

- 0

4'

- 0

8'

- 0

4'

- 0

8'

- 0

4'

- 0

1'

- 0

1'

- 0

4'

- 0

9' - 4"

4' - 0"

2' - 0"

4' - 0"

5' - 4"

1' - 4" 4' -

0"

10'

- 8

8' - 0"

10' - 5" 10' - 5"

A4.2

A3.1

1905.1

1901.1

1902.1

CONFERENCE/

CLASS/ MULTI

PURPOSE

TELE/D.F.

PASSAGE

VESTIBULE

PASSAGE

1024A

TELE/DATA

MEN'S LOCKER

WOMEN'S

LOCKER

MECH

ELECT.

1905B

DIST.

1905A

9.1

11' - 0"

5"

8"

6'

- 0

6'

- 8

6'

- 6

0"

14' - 3" 12' - 0 5/8" 11' - 0" 14' - 2 7/8"

11' - 7 1/2"

1019.1

8.1

1005.1

1005C.1

1005B.1

5A

.1

1802.1

1811.1

1620.1

5.1

AUDIO OFF.

1517151

7.1

6.2

1101A.1

PT OFFICE

1101A

3.1

2.1

0.1

9.1

DILATE/

SUBWAIT

ROUTE

0.1

1.1

8A

.1

MAINE VET

OFFICE

1005A

MAINE VET

CONFERENCE

1005B

MAINE VET

SECRETARY

MAINE VET

STORAGE

1005C

MED RECORDS

MAS OFFICE

1018REGISTRATION

/ CHECK IN

INFORMATION

1007 CHECK OUT

EXAM

1402.1

1' - 0"

WORK

WORK

PRIMARY

CARE/XRAY

WAITING

21 SEATS

13 SEATS

8 SEATS

18 SEATS

9'

- 6

9'

- 6

1503.1

1508.1

7' - 0" 7' - 0" 13' - 7" 7' - 3 7/8"

10' - 1 1/4"

2A

.1

IT / CL

1902A

29 SEATS

22 SEATS

EYEWASH

6 SEATS

7'

- 0

7'

- 5

3"

6"

5"

2' - 5" 14' - 0" 9' - 4 7/8" 9' - 4 7/8" 2' - 10 3/4"

9'

- 0

"135.00

11' - 6 1/2"

11' - 0"

7"

8' - 5"

9'

- 1

1" 9'

- 3

3'

- 0

1/ 2"

E.4

2'

- 0

7' -

0"

1/

2"

1905A.1

5.5

F.3

9'

- 0

7'

- 1 0"

6.1

1705.1 1705.2

1708.2

DRESS

DRESS

1702.1

STORAGE

1701.1

SUB WAIT

0.2

0.1

8' - 0"

7' - 0"

2'

- 0

8.1

5' - 6"

1009.2

0.1

EDUCATIONAL

CONF ROOM

TELEPHONE

ASSISTANCE

PROGRAM

STORAGE

6'

- 7

5/ 8"

9'

- 3

3/ 4"

1'

- 0

1'

- 0

5'

- 5

2 2

CLR12'

- 0

9 9

2 22222222222

1.2

A5.1

A5.1

5 5

MYHEVET

C.7

C.7

M.1 M.1

C.7

C.7

C.7

C.7

R.1

R.1

R.1 R.1

R.2R.2

R.2R.2

R.2 R.1R.1

R.1R.1

R.1

R.1R.1

R.1R.1

R.1R.1 R.1

R.1

R.1

5.3

6.2

PASSAGE

1712A

HAC

1707.1

E.6

4.6

A1.2

59' - 4"

A6.2

A6.2

A6.2

A7.1

A7.24

A7.1

A7.1

A7.1

TYP.

A7.1

A7.1

A7.1

A7.1

A7.1

A7.1

TYP.

A7.2

A7.1

A7.1

A7.1

A7.2

A7.3

A7.2

A7.3

A7.1

8'

- 0

1/ 2"

5'

- 9

1/ 2"

A7.2

A7.2

TYP.

A7.2

A7.2

A7.1

A7.2

A7.2 15 17

22 22

BL-1

BL-1

BL-1

BL-1

BL-1

R.1

FD

R.1R.1

R.1

R.1

A7.3

A7.3

FD

FD

BL-1

PASSAGE

1023A

PASSAGE

1024B

PASSAGE

1024C

PASSAGE

1024D

PASSAGE

1024B

PASSAGE

1024C

10'

- 2

13'

- 8

" R .O.

10'

- 2

A5.1

TYP.

3' - 0"

1025.2

OPP

OPP

1000.2

1711.1

A4.3

6'

- 4

4'

- 4

1711.2

A7.19A

1001.1

A4.1

1000.6

1000.4

1000.5

1 1

A5.1

11' - 9 7/8" 7' - 10 1/4"

7' - 6"

7'

- 6

6'

- 0

1/ 4"

1812.1

C.4

C.42'

- 8

1' - 8"

D.F.

F.4

F.4

27 27

27 27

2727 27

27 27

272727

9 9

A6.1

TELE/DATA

1901A

1901A.1

2'

- 0

182' - 0"

2'

- 0

182' - 0"

NEG.

PRESSURE

NEG.

PRESSURE

STUD FRAMING EXTENDED TO STRUCTURE ABOVE SHALL HAVE 3" x 3 5/8" GALVANIZED STUD TRACK AT TOP.

STUD FRAMING SHALL BE 3/4" FROM TOP OF TRACK AND HAVE NO MECHANICAL FASTENING TO ALLOW FOR 3/4"

DEFLECTION

VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ALIGNMENT OF WALLS. BRING ANY DISCREPANCIES TO

THE ARCHITECTS ATTENTION PRIOR TO START OF FABRICATION / CONSTRUCTION

A) PROVIDE 5/8" TYPE "X" GYPSUM BOARD AT ALL LOCATIONS UNLESS OTHERWISE NOTED.

B) PROVIDE 5/8" TYPE "X" MOISTURE RESISTANT GYPSUM BOARD AT PLUMBING PARTITIONS AND PARTITION

FACE WITHIN 6'-0" OF ALL PLUMBING FIXTURES

C) PROVIDE CEMENT PLASTER BOARD AS BACK-UP AT ALL CERAMIC WALL TILE LOCATIONS

HOLD 5/8" CLEARANCE BETWEEN FLOOR AND GYPSUM BOARD. FILL GAP BETWEEN BOTTOM EDGE OF GYPSUM BOARD AND FLOOR WITH MOISTURE RESISTANT MASTIC CAULKING. STRIKE COMPOUND SMOOTH AND FLUSH

WITH FACE OF PARTITION. REMOVE EXCESS MASTIC CAULKING FROM PARTITION AND FLOOR.

ALL VINYL OR FABRIC WALL COVERING AT CORRIDOR CORNER LOCATIONS TO RECEIVE A CLEAR PLASTIC CORNER GUARD TO A HEIGHT OF 8'-0" A.F.F.. ( IPC INSTITUTIONAL PRODUCTS CORP. #8118 OR APPROVED EQUAL

) UNLESS OTHER PROTECTION IS SPECIFIED

CHANGES IN FLOOR MATERIALS SHALL BE LOCATED AT THE CENTERLINE OF DOORS UNLESS NOTED

OTHERWISE

VERIFY LOCATION OF ACCESS PANELS WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR ACCESS TO

MECHANICAL AND ELECTRICAL ITEMS

SEAL PENETRATIONS IN FIRE RATED ASSEMBLIES AND SMOKE BARRIERS TO MEET REQUIRED RATINGS. UTILIZE

UL APPROVED METHODS

PROVIDE 16 GAUGE SHEET METAL BANDING AS REQUIRED TO SUPPORT ALL CABINETS, SHELVES, BUILT-INS, EQUIPMENT OR ACCESSORIES. COORDINATE WITH VENDOR DOCUMENTS WHERE SUCH CONDITIONS APPLY

ALL WALLS TO BE TYPE C.1 UNLESS NOTED OTHERWISE

NOTIFY THE ARCHITECT & VA PROJECT MANAGER IF ELECTRICAL / COMMUNICATION / HVAC / PLUMBING / ITEMS DEPICTED CONFLICT WITH ADA REQUIREMENTS OR INDUSTRY STANDARDS PRIOR TO INSTALLATION.

NOTE: ALL DEVICES AND CONTROLS TO BE INSTALLED WITHIN A MAXIMUM OF 4" OF EACH OTHER

HORIZONTALLY

( NOT 16" O.C. ) AND ALIGN THE BOTTOMS OF EACH ITEM. IN THE VERTICAL POSITION ALIGN THE ITEMS ON

CENTERLINES

DURING CONSTRUCTION , AREA SHALL BE KEPT BROOM CLEAN AND FREE OF DEBRIS.

LIGHTING, EXIT LIGHTING INFORMATION, ELECTRICAL, DATA AND TELEPHONE INFORMATION SHOWN ARE FOR ELECTRICAL CONTRACTORS REFERENCE ONLY. CONTRACTOR SHALL ENSURE COORDINATION OF ELECTRICAL ITEMS WITH BUILDING CONSTRUCTION AND EQUIPMENT AND SHALL OBTAIN THE NEEDED INFORMATION TO

PROVIDE A COMPLETE AND WORKING INSTALLATION

CONSTRUCTION SHALL BE IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL CODES.

PROVIDE C.1 PARTITION TYPE AROUND ALL TOILET ROOMS AND ADJUST WALL THICKNESS FOR PLUMBING. USE MOSITURE RESISTANT GYPSUM WALL BOARD & GALVANIZED METAL STUDS WITHIN 6'-0" OF ALL PLUMBING

FIXTURES.

PROVIDE "HANDILAV-GUARD" INSULATION KITS BY TRUEBRO INC. AT ALL ADA ACCESSIBLE LAVATORIES.

PROVIDE GFI ELECTRICAL OUTLETS AT LOCATIONS REQUIRED BY CODE.

SALVAGED MATERIAL SHALL BE CLEANED AND RETURNED TO THE OWNER AS DIRECTED.

PROVIDE CONTINUOUS VAPOR BARRIER (ON WARM SIDE OF WALL) ALONG ENTIRE PERIMETER OF EXTERIOR

WALL FROM FLOOR TO ROOF DECK. ALL PENETRATIONS TO BE SEALED.

ALL PENETRATIONS OF EXTERIOR WALL ARE TO BE MADE AIR TIGHT.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

GENERAL NOTES

CODED NOTES

PROVIDE BASE BUILDING STANDARD FULLY RECESSED FIRE EXTINGUISHER AND CABINET. MOUNT PER BASE BUILDING SPECIFICATIONS NOT TO EXCEED 25" A.F.F. TO FLOOR OF CABINET. USE 6" METAL STUDS

AT CABINET LOCATIONS.

PROVIDE BASE BUILDING STANDARD BLINDS AND SILL. (TYPICAL)

THIS ROOM TO RECEIVE LEAD SHIELDING 1/16" MIN. THICK. COORDINATE FINAL REQUIREMENTS WITH

PHYSICIST REPORT.

PROVIDE WALL MOUNTED TV BRACKET. COORDINATE MOUNTING HEIGHT WITH OWNER.

PROVIDE CARD ACCESS AT THIS DOOR

PROVIDE 4'-0" x 4'-0" PLYWOOD MOUNTED AT 3'-0" A.F.F.

24" x 24" FLOOR MOUNTED SERVICE SINK. REFER TO PLUMBING DRAWINGS.

PROVIDE EYE WASH STATION THIS LOCATION

OWNER PROVIDED FURNITURE EQUIPMENT

PROVIDE 5 HIGH SHELVING - SEE DETAIL 12/A5.1

ROUGH IN PLUMBING - REFER TO PLUMBING DRAWINGS.

EMERGENCY SHOWER/EYEWASH - REFER TO PLUMBING DRAWINGS.

CEILING MOUNTED PROJECTION SCREEN. COORDINATE LOCATION WITH OWNER.

2 HIGH ADJUSTABLE SHELVING.

GAS METER LOCATION

CEILING MOUNTED PROJECTOR. COORDINATE LOCATION WITH OWNER.

BULLET PROOF GLASS

PROVIDE FIRE CAULK WHERE RATED PARTITION MEETS COLUMN AND ADHERE 5/8" TYPE "X" GYP. BD.

DIRECTLY TO REMAINING EXPOSED COLUMN.

OPENING IN CEILING TO ACCOMODATE "PRECISION LADDERS" PULL DOWN STAIR.

BENCH - REFER TO ELEVATION 13/A7.2

PROVIDE 3 HIGH SHELVING - SEE DETAIL 13/A5.1

48" HIGH HALF WALL - SEE DETAIL 9/A5.1

ACCORDIAN FOLDING PARTITION - SEE DETAILS 16/A5.1 & 12/S401

CONTRACTOR PROVIDED INSTALLED LOCKERS W/ SLOPED TOPS, PROVIDE BLOCKING AS REQ'D - SEE

SPECIFICATION FOR MORE INFO.

FUME HOOD - OWNER PROVIDED, CONTRACTOR INSTALLED

PROVIDE ROUGH IN ONLY FOR SINK

IPC CORNER GUARDS 4'-0" LONG - SEE FINISH LEDGEND FOR TYPE.

PROVIDE HANDRAIL - REFER TO FINISH LEDGEND FOR TYPE.

FIRE ALARM ELECTICAL PANEL - REFER TO ELECTRICAL DWGS.

PROVIDE 4'-0" HEIGHT CONCRETE BOLLARDS

H/L DRINKING FOUNTAINS

PROVIDE SPECIMEN PASS THRU. REFER TO MOUNTING HEIGHTS FOR FURTHER INFO. T 1/A6.1.

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

A1.1

FLOOR PLAN

VA

Outpatient

Clinic

03/19/2010

28112

SCALE: 1/8" = 1'-0"1 FLOOR PLAN

PLAN NORTH TRUE NORTH

B

2 3 4 5 6 7

C

D

E

F

G

H

F.8'

5.8'

7.8'

E.8'

3.9

A

4.7 5.6 6.6

2.5'

1.5'

C.3'

C.5'

D.5'

0.5'

3.5'

1.3'

2.3'

AUDIO SOUND

BOOTH

AUDIO SOUND

BOOTH

AUDIO OFF.

PAT. TLT.

PHYS. OFFICE

PHYS. EXTEND

ST. TOILET

EXAM

AUDIO OFFICE

AUDIO OFFICE

CAMERA

DISPENS.

1503 EXAM

MECH.

1408A

HYGIENE

ORAL EXAM

VISUAL FIELDS

EXAM-EYE

LANE

DENTAL

IMAGING

EXAM-EYE

LANE

PATIENT

TOILET

SOIL. SPD

CART

SEC./REC.

ORAL EXAM

ORAL EXAM

STORAGE

ORAL SURG.

CLEAN

INSTRUMENTS

GROUP

THERAPY

1306OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

GROUP

THERAPY

DENTAL/

PROSTH. LAB

RECOV. RM.

OFFICE

HEALTH TECH

OFF. ADMIN

ASST.

PASSAGE

1416C

PASSAGE

1321A

PASSAGE

PASSAGE

1321B

UTIL/STG

WAITING

PATIENT TLT

PATIENT TLT

OFFICE

OFFICE

PASSAGE

1321C

PASSAGE

1416A

PASSAGE

1416B

PASSAGE

PASSAGE

PASSAGE

1521A

PASSAGE

1633D

CRASH CT.

PAT. TLT

EXAM

EXAM

EXAM

EXAM

SPECIALTY

WAITING

PASSAGE

1633C

STORAGE

CLEAN UTIL.

SOIL UTIL.

PHYS. OFF.

PHYS. EXTEND.

PHYS. OFFICE

EXAM

EXAM

EXAM

EXAM/GYN.

ST. TOILET

CLINIC

MANAGER

URG. CARE

OBSVER/TREAT

EXAM

READING

PHYS. OFFICE

IMAGING

PASSAGE

TECH. OFF.

ULTRASOUND

HAC.

PAT. TLT

MED RECORDS

EMS SUPPLY

STERILE / NON

STERILE STOR

VESTIBULE

CL LIN.

SOIL LIN.

1804 IT/BIO MED

INFECT WASTE

1811 CL REC. / BULK

STOR

MAS STOR.,

SPLY, EQ.

PASSAGE

MEN'S TLT.

COMP/PEN

TELEHEALTH

PATIENT

TOILET

1101C

HYDRO THER.

1101D

OFFICE, SOC.

WKR.

OFFICE NURSE

TREATMENT/EXERCISE

WAIT

OFFICE NURSE

OFFICE NURSE

VOL/ESCORT

WAIT

1003VESTIBULE

STOR.

1101B

PASSAGE

PASSAGE

1633A

NURSE

PASSAGE

STAFF TLT

PASSAGE

1633B

AUDIO SUPPLY

VESTIBULE

SOC. WKR.

OFFICE

OFFICE

PATIENT

TOILET

USC/TOILET

MEDS

BLOOD DRAW

BLOOD DRAW

CONSULT #2

STORAGE

1008A LAB

HAZ STOR

1204A

P.T. WAIT

MEN'S TLT.

WOMEN'S TLT.

OPEN OFFICE

1620EXAM-EYE

LANE

EXAM-EYE

LANE

OFFICE

PRIMARY CARE

WAITING

WOMEN'S TLT.

NURSE

CORRIDOR

PHARMACY /

TRANS

CONSULT #1

PASSAGE

1205A

NURSE

WAITING

D.4

C.4

6.8'

C.2

C.6

2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0" 2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0" 2 9' - 0"

1 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0" 2 9' - 0"

2 8' - 10"

2 9' - 0"

2 9' - 0"

2 9' - 0"2 9' - 0"

2 9' - 0"

2 9' - 0"

DIST.

1905A

MECH

WOMEN'S

LOCKER

MEN'S LOCKER

MED RECORDS

MAINE VET

STORAGE

1005C

MAINE VET

CONFERENCE

1005B

MAINE VET

SECRETARY

MAINE VET

OFFICE

1005A

MAS OFFICE

TELE/DATA

PT OFFICE

1101A

PRIMARY

CARE/XRAY

WAITING

E.4

5.5

F.3

11'

- 0

0"

1'

- 0

1' - 0"

DRESS

DRESS

TELEPHONE

ASSISTANCE

PROGRAM

STORAGE

ROUTE

CHECK OUT

REGISTRATION

/ CHECK IN

VESTIBULE

PASSAGE

1024A

3 7' - 8"

4' - 0"

E.6

4.6

A1.2

PASSAGE

1712A

HAC

3 8' - 0"

3 7' - 8"

2 9' - 0"

2 9' - 0"

2 9' - 0"

2 9' - 0"

3 7' - 2"

2 9' - 0"

2 9' - 0" 2 9' - 0"

3 7' - 8"

3 7' - 8"3 7' - 8"

3 7' - 8"

3 7' - 8"

2 9' - 0"

3 8' - 0"

2 9' - 0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0" 4 9'-0"

4 9'-0" 4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0" 4 9'-0" 4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

4 9'-0"

AUDIO SOUND

BOOTH

AUDIO SOUND

BOOTH

AUDIO OFF.

PAT. TLT.

PHYS. OFFICE

PHYS. EXTEND

ST. TOILET

EXAM

AUDIO OFFICE

AUDIO OFFICE

CAMERA

DISPENS.

1503 EXAM

MECH.

1408A

HYGIENE

ORAL EXAM

VISUAL FIELDS

EXAM-EYE

LANE

DENTAL

IMAGING

EXAM-EYE

LANE

PATIENT

TOILET

SOIL. SPD

CART

SEC./REC.

ORAL EXAM

ORAL EXAM

STORAGE

ORAL SURG.

CLEAN

INSTRUMENTS

GROUP

THERAPY

1306OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

GROUP

THERAPY

DENTAL/

PROSTH. LAB

RECOV. RM.

OFFICE

HEALTH TECH

OFF. ADMIN

ASST.

PASSAGE

1416C

PASSAGE

1321A

PASSAGE

PASSAGE

1321B

UTIL/STG

WAITING

PATIENT TLT

PATIENT TLT

OFFICE

OFFICE

PASSAGE

1321C

PASSAGE

1416A

PASSAGE

1416B

PASSAGE

PASSAGE

PASSAGE

1521A

PASSAGE

1633D

CRASH CT.

PAT. TLT

EXAM

EXAM

EXAM

EXAM

SPECIALTY

WAITING

PASSAGE

1633C

STORAGE

CLEAN UTIL.

SOIL UTIL.

PHYS. OFF.

PHYS. EXTEND.

PHYS. OFFICE

EXAM

EXAM

EXAM

EXAM/GYN.

ST. TOILET

CLINIC

MANAGER

URG. CARE

OBSVER/TREAT

EXAM

READING

PHYS. OFFICE

IMAGING

PASSAGE

TECH. OFF.

ULTRASOUND

HAC.

PAT. TLT

MED RECORDS

EMS SUPPLY

STERILE / NON

STERILE STOR

VESTIBULE

CL LIN.

SOIL LIN.

1804 IT/BIO MED

INFECT WASTE

1811 CL REC. / BULK

STOR

MAS STOR.,

SPLY, EQ.

PASSAGE

MEN'S TLT.

COMP/PEN

TELEHEALTH

PATIENT

TOILET

1101C

HYDRO THER.

1101D

OFFICE, SOC.

WKR.

OFFICE NURSE

TREATMENT/EXERCISE

WAIT

OFFICE NURSE

OFFICE NURSE

VOL/ESCORT

WAIT

1003VESTIBULE

STOR.

1101B

PASSAGE

PASSAGE

1633A

NURSE

PASSAGE

STAFF TLT

PASSAGE

1633B

AUDIO SUPPLY

VESTIBULE

SOC. WKR.

OFFICE

OFFICE

PATIENT

TOILET

USC/TOILET

MEDS

BLOOD DRAW

BLOOD DRAW

CONSULT #2

STORAGE

1008A LAB

HAZ STOR

1204A

P.T. WAIT

MEN'S TLT.

WOMEN'S TLT.

OPEN OFFICE

EXAM-EYE

LANE

OFFICE

PRIMARY CARE

WAITING

WOMEN'S TLT.

NURSE

CORRIDOR

PHARMACY /

TRANS

CONSULT #1

PASSAGE

1205A

NURSE

WAITING

ELECT.

1905B

WOMEN'S

LOCKER

MEN'S LOCKER

MED RECORDS

MAINE VET

STORAGE

1005C

MAINE VET

CONFERENCE

1005B

MAINE VET

SECRETARY

MAINE VET

OFFICE

1005A

MAS OFFICE

TELE/DATA

PT OFFICE

1101A

PRIMARY

CARE/XRAY

WAITING

DRESS

DRESS

TELEPHONE

ASSISTANCE

PROGRAM

STORAGE

ROUTE

CHECK OUT

REGISTRATION

/ CHECK IN

VESTIBULE

PASSAGE

1024A

PASSAGE

1712A

HAC

3 7' - 8"

NO CEILING

NO CEILING

NO CEILING

NO CEILING

NO CEILING

AUDIO SOUND

BOOTH

AUDIO SOUND

BOOTH

AUDIO OFF.

PAT. TLT.

PHYS. OFFICE

PHYS. EXTEND

ST. TOILET

EXAM

AUDIO OFFICE

AUDIO OFFICE

CAMERA

DISPENS.

1503 EXAM

MECH.

1408A

HYGIENE

ORAL EXAM

VISUAL FIELDS

EXAM-EYE

LANE

DENTAL

IMAGING

EXAM-EYE

LANE

PATIENT

TOILET

SOIL. SPD

CART

SEC./REC.

ORAL EXAM

ORAL EXAM

STORAGE

ORAL SURG.

CLEAN

INSTRUMENTS

GROUP

THERAPY

1306OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

GROUP

THERAPY

DENTAL/

PROSTH. LAB

RECOV. RM.

OFFICE

HEALTH TECH

OFF. ADMIN

ASST.

PASSAGE

1416C

PASSAGE

1321A

PASSAGE

PASSAGE

1321B

UTIL/STG

WAITING

PATIENT TLT

PATIENT TLT

OFFICE

OFFICE

PASSAGE

1321C

PASSAGE

1416A

PASSAGE

1416B

PASSAGE

PASSAGE

PASSAGE

1521A

PASSAGE

1633D

CRASH CT.

PAT. TLT

EXAM

EXAM

EXAM

EXAM

SPECIALTY

WAITING

PASSAGE

1633C

STORAGE

CLEAN UTIL.

SOIL UTIL.

PHYS. OFF.

PHYS. EXTEND.

PHYS. OFFICE

EXAM

EXAM

EXAM

EXAM/GYN.

ST. TOILET

CLINIC

MANAGER

URG. CARE

OBSVER/TREAT

EXAM

READING

PHYS. OFFICE

IMAGING

PASSAGE

TECH. OFF.

ULTRASOUND

HAC.

PAT. TLT

MED RECORDS

EMS SUPPLY

STERILE / NON

STERILE STOR

VESTIBULE

CL LIN.

SOIL LIN.

1804 IT/BIO MED

INFECT WASTE

1811 CL REC. / BULK

STOR

MAS STOR.,

SPLY, EQ.

PASSAGE

MEN'S TLT.

COMP/PEN

TELEHEALTH

PATIENT

TOILET

1101C

HYDRO THER.

1101D

OFFICE, SOC.

WKR.

OFFICE NURSE

TREATMENT/EXERCISE

WAIT

OFFICE NURSE

OFFICE NURSE

VOL/ESCORT

WAIT

1003VESTIBULE

STOR.

1101B

PASSAGE

PASSAGE

1633A

NURSE

PASSAGE

STAFF TLT

PASSAGE

1633B

AUDIO SUPPLY

VESTIBULE

SOC. WKR.

OFFICE

OFFICE

PATIENT

TOILET

USC/TOILET

MEDS

BLOOD DRAW

BLOOD DRAW

CONSULT #2

STORAGE

1008A LAB

HAZ STOR

1204A

P.T. WAIT

MEN'S TLT.

WOMEN'S TLT.

OPEN OFFICE

EXAM-EYE

LANE

OFFICE

PRIMARY CARE

WAITING

WOMEN'S TLT.

NURSE

CORRIDOR

PHARMACY /

TRANS

CONSULT #1

PASSAGE

1205A

NURSE

WAITING

DIST.

1905A

MECH

WOMEN'S

LOCKER

MEN'S LOCKER

MED RECORDS

MAINE VET

STORAGE

1005C

MAINE VET

CONFERENCE

1005B

MAINE VET

SECRETARY

MAINE VET

OFFICE

1005A

MAS OFFICE

TELE/DATA

PT OFFICE

1101A

PRIMARY

CARE/XRAY

WAITING

DRESS

DRESS

TELEPHONE

ASSISTANCE

PROGRAM

STORAGE

ROUTE

CHECK OUT

REGISTRATION

/ CHECK IN

VESTIBULE

PASSAGE

1024A

PASSAGE

1712A

HAC

AUDIO SOUND

BOOTH

AUDIO SOUND

BOOTH

AUDIO OFF.

PAT. TLT.

PHYS. OFFICE

PHYS. EXTEND

ST. TOILET

EXAM

AUDIO OFFICE

AUDIO OFFICE

CAMERA

DISPENS.

1503 EXAM

MECH.

1408A

HYGIENE

ORAL EXAM

VISUAL FIELDS

EXAM-EYE

LANE

DENTAL

IMAGING

EXAM-EYE

LANE

PATIENT

TOILET

SOIL. SPD

CART

SEC./REC.

ORAL EXAM

ORAL EXAM

STORAGE

ORAL SURG.

CLEAN

INSTRUMENTS

GROUP

THERAPY

1306OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

GROUP

THERAPY

DENTAL/

PROSTH. LAB

RECOV. RM.

OFFICE

HEALTH TECH

OFF. ADMIN

ASST.

PASSAGE

1416C

PASSAGE

1321A

PASSAGE

PASSAGE

1321B

UTIL/STG

WAITING

PATIENT TLT

PATIENT TLT

OFFICE

OFFICE

PASSAGE

1321C

PASSAGE

1416A

PASSAGE

1416B

PASSAGE

PASSAGE

PASSAGE

1521A

PASSAGE

1633D

CRASH CT.

PAT. TLT

EXAM

EXAM

EXAM

EXAM

SPECIALTY

WAITING

PASSAGE

1633C

STORAGE

CLEAN UTIL.

SOIL UTIL.

PHYS. OFF.

PHYS. EXTEND.

PHYS. OFFICE

EXAM

EXAM

EXAM

EXAM/GYN.

ST. TOILET

CLINIC

MANAGER

URG. CARE

OBSVER/TREAT

EXAM

READING

PHYS. OFFICE

IMAGING

PASSAGE

TECH. OFF.

ULTRASOUND

PROCEDURE

HAC.

PAT. TLT

MED RECORDS

EMS SUPPLY

STERILE / NON

STERILE STOR

VESTIBULE

CL LIN.

SOIL LIN.

1804 IT/BIO MED

INFECT WASTE

1811 CL REC. / BULK

STOR

MAS STOR.,

SPLY, EQ.

PASSAGE

MEN'S TLT.

COMP/PEN

TELEHEALTH

PATIENT

TOILET

1101C

HYDRO THER.

1101D

OFFICE, SOC.

WKR.

OFFICE NURSE

TREATMENT/EXERCISE

WAIT

OFFICE NURSE

OFFICE NURSE

VOL/ESCORT

WAIT

1003VESTIBULE

STOR.

1101B

PASSAGE

PASSAGE

1633A

NURSE

PASSAGE

STAFF TLT

PASSAGE

1633B

AUDIO SUPPLY

VESTIBULE

SOC. WKR.

OFFICE

OFFICE

PATIENT

TOILET

USC/TOILET

MEDS

BLOOD DRAW

BLOOD DRAW

CONSULT #2

STORAGE

1008A LAB

HAZ STOR

1204A

P.T. WAIT

MEN'S TLT.

WOMEN'S TLT.

OPEN OFFICE

EXAM-EYE

LANE

OFFICE

PRIMARY CARE

WAITING

WOMEN'S TLT.

NURSE

CORRIDOR

PHARMACY /

TRANS

CONSULT #1

PASSAGE

1205A

NURSE

WAITING

ELECT.

1905B

WOMEN'S

LOCKER

MEN'S LOCKER

MED RECORDS

MAINE VET

STORAGE

1005C

MAINE VET

CONFERENCE

1005B

MAINE VET

SECRETARY

MAINE VET

OFFICE

1005A

MAS OFFICE

CONFERENCE/

CLASS/ MULTI

PURPOSE

TELE/DATA

PT OFFICE

1101A

PRIMARY

CARE/XRAY

WAITING

DRESS

DRESS

TELEPHONE

ASSISTANCE

PROGRAM

DILATE/

SUBWAIT

STORAGE

ROUTE

EDUCATIONAL

CONF ROOM

CHECK OUT

REGISTRATION

/ CHECK IN

VESTIBULE

PASSAGE

1024A

PASSAGE

1712A

HAC

TYP.

4 2

3 4

A5.1

A5.1

TELE/DATA

1901A

2'x4' 1'x4' 2'x2'

S

EXIT

SIGN

P - PARABOLIC LENS

NEW - NEW FIXTURE TO MATCH EXISTING

REL - TO BE RELOCATED

TBR - TO BE REMOVED

ETR - EXISTING TO REMAIN

EP - EMERGENCY POWER: FIXTURE TO BE ON NIGHT LIGHT CIRCUIT

SLOT DIFFUSER

CEILING PLAN LEGEND

CUBICAL

CURTAIN TRACK

SUPPLY ACCESS

PANEL

RETURN

FLUORESCENT LIGHT FIXTURES WALL WASHING

LIGHT

SPEAKER

CLG. HEIGHT

CLG. TYPE

SPRINKLER

HEAD

PENDANT

LIGHT

WALL

SCONCE

DOWN

LIGHT

CODED NOTES

CUBICAL CURTAIN TRACK - REFER TO DETAIL 15/A5.1

CEILING TRACK FOR FOLDING PARTITION. REFER TO DETAIL 16/A5.1

RECESSED FOLD DOWN PROJECTOR SCREEN

OVERHEAD PROJECTOR

PROVIDE 3'x3' ACCESS PANEL ABOCE CEILING FOR ACCESS TO MECHANICAL DUCTWORK.

FOLD DOWN STAIRWAY

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

A1.1C

REFLECTED CEILING

PLAN

VA

Outpatient

Clinic

03/19/2010

28112

SCALE: 1/8" = 1'-0"1 REFLECTED CEILING PLAN

CEILING PLAN GENERAL NOTES

ALL CEILINGS TO BE TYPE 1 UNLESS NOTED OTHERWISE ON REFLECTED CEILING PLAN.

ALL CEILING HEIGHTS TO BE 9'-0", UNLESS NOTED OTHERWISE ON REFLECTED CEILING PLAN.

PROVIDE DUAL LEVEL SWITCHING & 3 LAMPS IN ALL ROOMS GREATER THAN

100 SQ. FT. IN AREA

COORDINATE CEILING TYPE SHOWN ON REFLECTED CEILING PLAN W/ INTERIOR FINISHES SCHEDULE. BRING

ANY DISCREPANCIES TO THE ARCHITECT'S ATTENTION.

1.

2.

3.

4.

1 2'X4' TEGULAR "SECOND LOOK" LAY-IN ACOUSTICAL CEILING TILE

2 2'X4' VINYL FACED GYP. BD. TILE

3 5/8" TYPE "X" GYP BD ON METAL STUDS

4 4-7/8" BULKHEAD

CEILING TYPES

4 5 6

F

G

3.9

A3.1

4"

1'

- 4

11' - 10" 29' - 10" 1' - 4"

5.5

F.3

2'

- 6

1/ 8"

1/

2" 1 2

2000.1

E.6

4.6

A1.2

REFER TO MECHANICAL

DRAWINGS FOR FURTHER

INFORMATION. COORDINATE

CONCRETE EQUIPMENT PADS

W/ STRUCTURAL DRAWINGS.

A1.2

A1.2

7' - 6" 3 5/8"

3'

- 4

0 1

/2" PENTHOUSE

43' - 0"

6"

CODED NOTES

PROVIDE OPENING IN FLOOR TO ACCOMODATE "PRECISION LADDERS" FOLDING STAIR.

PROVIDE 42" HIGH METAL RAILING WITH 3'-0" WIDE SELF CLOSING GATE AT TOP OF STAIR AS SHOWN.

FINISH FLOOR

ELEV. = 100' - 0"

TOP OF STEEL

ELEV. = 113' - 4"

5.5

3'-6" GUARDRAIL WITH 3'-0" WIDE GATE AT TOP OF

STAIR. ACCESSORY PROVIDED BY LADDER

SUPPLIER.

PROVIDE 2'-6" x 7'-5 1/8" ROUGH OPENING FOR FOLD

DOWN STAIR. COORDINATE WITH STRUCTURAL

DRAWINGS AND MECHANICAL CONTRACTOR FOR

EXACT LOCATION

"SUPER SIMPLEX" FOLD DOWN STAIRWAY

PRODUCT BY PRECISION LADDERS, LLC. (OR

APPROVED EQUAL)

PAINT COVER TO MATCH CEILING GRID

ACOUSTICAL CEILING TILE

PROVIDE ROUGH OPENING IN CEILING -

COORDINATE SIZE WITH MANUFACTURER

SHROUD BY STAIR SUPPLIER

9'

- 0

TOP OF MECH SCREEN

ELEV. = 128' - 8"

TOP OF STEEL

ELEV. = 113' - 4"

4.6

"FORMABOND METAL WALL PANEL

SYSTEM OR APPROVED EQUAL ON

EXTERIOR SHEATHING

6" 18 GA STEEL STUDS

@ 16" O.C. WITH 6" (R-19

@ 75° F) BATT INSULATION

COMMERCIAL GRADE TYVEK

OVER EXTERIOR SHEATHING, TYP.

5/8" "DENS-GLASS GOLD"

WATER RESISTANT GYPSUM

SHEATHING

5/8" TYPE "X" FIRE RESISTIVE GYPSUM

WALL BOARD

6 MIL. VAPOR BARRIER

PREFINISHED METAL FLASHING

EXTEND UP 16" MIN.

CANT STRIP

60 MIL. BALLASTED E.P.D.M.

MEMBRANE ROOFING SYSTEM

ON 3" MIN. RIGID INSULATION (R-

7.5 PER IN.) OVER 5/8" WATER

RESISTANT GYPSUM ROOF DECK

THERMAL BARRIER ON 1-1/2"

METAL DECK (REFER TO

STRUCTURAL)

CONCRETE SLAB ON METAL DECK (SEE

STRUCTURAL DRAWINGS)

PENTHOUSE T.O.S.

ELEV. = 127' - 9 1/2"

PREFINISHED METAL FLASHING

SLOPE TOP PIECE OF P.T.

WOOD BLOCKING TO PROVIDE

POSITIVE DRAINAGE

2x P.T. WOOD BLOCKING 60 MIL BALLASTED, E.P.D.M.

MEMBRANE ROOFING SYSTEM ON 3"

MIN. RIGID INSULATION OVER 5/8"

SHEATHING ON 1-1/2" METAL DECKING

TOP OF MECH SCREEN

ELEV. = 128' - 8"

TOP OF STEEL

ELEV. = 113' - 4"

E.6

"FORMABOND METAL WALL PANEL

SYSTEM OR APPROVED EQUAL ON

EXTERIOR SHEATHING

6" 18 GA STEEL STUDS

@ 16" O.C. WITH 6" (R-19

@ 75° F) BATT INSULATION

COMMERCIAL GRADE TYVEK

OVER EXTERIOR SHEATHING, TYP.

5/8" "DENS-GLASS GOLD"

WATER RESISTANT GYPSUM

SHEATHING

5/8" TYPE "X" FIRE RESISTIVE GYPSUM

WALL BOARD

6 MIL. VAPOR BARRIER

5/8" TYPE "X" FIRE RESISTIVE GYPSUM

WALL BOARD

6 MIL. VAPOR BARRIER

PREFINISHED METAL FLASHING

CANT STRIP

60 MIL. BALLASTED E.P.D.M.

MEMBRANE ROOFING SYSTEM

ON 3" MIN. RIGID INSULATION (R-

7.5 PER IN.) OVER 5/8" WATER

RESISTANT GYPSUM ROOF DECK

THERMAL BARRIER ON 1-1/2"

METAL DECK (REFER TO

STRUCTURAL)

CONCRETE SLAB ON METAL DECK (SEE

STRUCTURAL DRAWINGS)

PENTHOUSE T.O.S.

ELEV. = 127' - 9 1/2"

PREFINISHED METAL FLASHING

SLOPE TOP PIECE OF P.T.

WOOD BLOCKING TO PROVIDE

POSITIVE DRAINAGE

2x P.T. WOOD BLOCKING

60 MIL BALLASTED, E.P.D.M.

MEMBRANE ROOFING SYSTEM ON 3"

MIN. RIGID INSULATION OVER 5/8"

SHEATHING ON 1-1/2" METAL DECKING

DRAW BAND SET IN ELASTOMERIC

E.P.D.M. MEMBRANE WITH APPROPRIATE

PREFABRICATED COVER ADHERED TO

SEAL EDGE OF COVER WITH LAP EDGE

E.P.D.M. MEMBRANE

SEALANT

ADHESIVE

MASTIC

SEALANT

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

A1.2

PENTHOUSE PLAN AND

DETAILS

VA

Outpatient

Clinic

03/19/2010

28112

SCALE: 1/8" = 1'-0"1 PENTHOUSE PLAN

SCALE: 1/2" = 1'-0"2 SECTION @ DISAPPEARING STAIR

PLAN NORTH TRUE NORTH

SCALE: 3/4" = 1'-0"3 SECTION @ PENTHOUSE WALL 1

SCALE: 3/4" = 1'-0"4 SECTION @ PENTHOUSE WALL 2

SCALE: 1/8" = 1'-0"5 ROOF PENETRATION

%%UCU-1

%%UCU-2

EQUIPMENT

SUPPORT RAIL

(TYP)

EQUIPMENT

SUPPORT RAIL

(TYP)

B

2 3 4 5 6 7

C

D

E

F

G

A2.1 4

A4.2

A4.3

E.8'

3.9

A

4.7 5.6 6.6

2.5'

1.5'

C.3'

C.5'

D.5'

0.5'

3.5'

1.3'

2.3'

A4.1

A4.1

A4.1

A4.1

C.4

6.8'

C.2

C.6

PITCHED

STRUCTURE

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

R.D.

(-7.5")

O.F.D. - OVERFLOW DRAIN @ 3" ABOVE

ROOF SURFACE. INSULATED PIPES TO

BRASS TONGUE OUTLET. COORDINATE

WITH PLUMBING (TYPICAL)

R.D.

(-7.5")

(0") (0")

(0")

(0")

(0")

10' - 0"

A4.2

A4.2

A4.2

A4.3

A4.2

A3.1

PI

TC

HE

D

ST

RU

CT

UR

E

(0")

PITCHED

STRUCTURE

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

PI

TC

HE

D

ST

RU

CT

UR

E

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

PI

TC

HE

D

ST

RU

CT

UR

E

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

(0")(0")(0")

(0")

(0") (0") (0") (0") (0")

(0")

(0")(0")(0")

(0")

(0")(0")(0")

(0") (0") (0")(0")(0")

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

TAPERED

INSULATION

TA

PE

RE

D

IN

SU

LA

TIO

N

0"

(-6.5")

(-6.5")

(0")

R.D.

(-12.5")

60 MIL. BALLASTED E.P.D.M. MEMBRANE ROOFING SYSTEM

ON 3" MIN. RIGID INSULATION OVER 5/8" WATER RESISTANT

GYPSUM SHEATHING ON THERMAL BARRIER ON 1-1/2"

METAL DECK (REFER TO STRUCTURAL)

PITCHED

STR

UCTURE

PITCHED

STR

UCTURE

PITCHED

STRUCTURE

23' - 0"

62'

- 0

1' - 1"

13'

- 1

0"

1' - 1"

(0")

PI

TC

HE

D

ST

RU

CT

UR

E

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

PITCHED

STRUCTURE

PITCHED

STRUCTURE

PITCHED

STRUCTURE

R.D.

(-7.5")

R.D.

(-7.5")

PITCHED

STRUCTURE

R.D.

(-7.5")

PI

TC

HE

D

ST

RU

CT

UR

E

PI

TC

HE

D

ST

RU

CT

UR

E

PITCHED

STRUCTURE

E.4

TAPERED

INSULATION

TAPERED

INSULATION

PI

TC

HE

D

ST

RU

CT

UR

E

PI

TC

HE

D

ST

RU

CT

UR

E

O.F.D.

O.F.D.

10' - 0"

O.F.D.

0"

10' - 0"

R.D.

(-7.5")

10' - 0"

O.F.D.

10' - 0"

O.F.D.

O.F.D.

(+7.5")

(+7.5")

5.5

F.3

ROOF SCUPPER

ROOF SCUPPER

TAPERED

INSULATION

TAPERED

INSU

LATIO

N

E.6

4.6

TAPERED

INSULATION

R.D.

(-6")

R.D.

(-5.5")

A1.2

A1.2

R.D.

(-3")

R.D.

(-3")

TAPERED

INSULATION

TAPERED

INSULATION

TAPERED

INSULATION

TA

PE

RE

D

IN

SU

LA

TIO

N

TA

PE

RE

D

IN

SU

LA

TIO

N

PITCHED

STRUCTURE

PROVIDE 24" WIDE WALKPADS AROUND

MECHANICAL EQUIPMENT

PROVIDE 24" WIDE WALKPADS FROM

DOOR TO WALKPADS AROUND

MECHANICAL EQUIPMENT

PI

TC

HE

D

ST

RU

CT

UR

E

PI

TC

HE

D

ST

RU

CT

UR

E

(0")

TAPERED

INSULATION

TA

PE

RE

D

IN

SU

LA

TIO

N

PROVIDE METAL FLASHING -

SLOPE TO PROVIDE DRAINAGE TO

ROOF SURFACE ON EITHER SIDE

R.D.

(-6")

TAPERED

INSULATION

TAPERED

INSULATION

O.F.D.

O.F.D.

0"

10' - 0"

21675 LONG VIEW DRIVE

SUITE 500

WAUKESHA, WI 53186

FAX (262) 798.7001

PHONE (262) 798.7000

E-MAIL welman@welmanarch.com

PROJECT NO.

DATE:

REVISION / ISSUES:

SHEET NAME:

SHEET NO:

C COPYRIGHT BY WELMAN

ARCHITECTS INC.

PROJECT:

03.19.2010 FTG/FND SUBMITTAL

CONTRACTOR:

889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910

03.26.2010 Design Development Review I & II

04.02.2010 75% VA Review

04.16.2010 City Submittal

05.21.2010 CB #1

05.21.2010 100% VA Review

35 State Hospital Drive

Bangor, ME 04401

A1.3

ROOF PLAN

VA

Outpatient

Clinic

03/19/2010

28112

SCALE: 1/8" = 1'-0"1 ROOF PLAN

FINISH FLOOR

ELEV. = 100' - 0"

TOP OF WALL

ELEV. = 114' - 0 1/2"

BCDEFGH A

A4.1

A4.1

A4.1

A4.1 4 D.4 C.4 C.2C.6

31 1 1 1 12 2 21 1 1 1

A3.1 1 E.4

F.3 E.6

A1.2

A4.3

PENTHOUSE T.O.S.

ELEV. = 127' - 9…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .