2024 WRVA - Roof Assemblies.pdf

PDF 299 KB Posted

Attached to
Z1DA--523A4-24-010 Replace Pool Roof Federal contract opportunity
Solicitation number
36C24124B0021
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

This document contains a proposal for roof replacement projects at a Veterans Affairs Medical Center. The Garland Company submitted technical specifications for replacing multiple roof sections, including upper PVC, ballasted EPDM, and swimming pool roofs. The roof assemblies proposed consist of mechanically fastened or fully adhered tapered polyiso insulation and cover boards set in adhesive, along with various membrane options such as Sarnafil PVC, EPDM, and KEE-Stone cap sheets. Replacement work includes removal and disposal of existing roof systems and installation of new assemblies per the specifications outlined.

A related federal contract opportunity from the Department of Veterans Affairs seeks bids to remove and replace the pool roof under solicitation number 36C24124B0021. The work location is specified as project 523A4-24-010 at the VAMC West Roxbury facility.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--523A4-24-010 Replace Pool Roof, newest first.
File Type Posted
BID OPENING Information.docx DOCX document
36C24124B0021 0002.docx DOCX document
36C24124B0021 0001.docx DOCX document
211_2131_261029_exhaust_fan_detail_KEE-Layout.pdf PDF
211_2131_261005_Raised_Metal_Edge_KEE-Layout.pdf PDF
S02 - MA WD 01-19-24.txt TXT text file
Pool Roof RFIs 1-10.docx DOCX document
Sloped Roof Photo.jpg JPG image
Section 075501 Pool Roof Upper Elevation.docx DOCX document
As Built Low Roof Plans Part A and B.pdf PDF
Garland Roof Measurement Report.pdf PDF
211_2131_261002_typical_section_finish_KEE-Layout.pdf PDF
523A4-24-010_ Pool roof - Sign in sheet.pdf PDF
211_2131_261006_Raised_Metal_Edge_Cap_KEE-Layout.pdf PDF
211_2131_261012_coping_cap_KEE-Layout 02.pdf PDF
S02 - ICRA.pdf PDF
S02 - SOW 523A4-24-010.docx DOCX document
S02 - Drawing Cutsheet.pdf PDF
S02 - Specifications.pdf PDF
S02 - MA WD (12-08-2023).txt TXT text file
S02 - PCRA.pdf PDF
36C24124B0021.docx DOCX document
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THE GARLAND COMPANY, INC.

HIGH PERFORMANCE ROOFING AND BUILDING ENVELOPE SYSTEMS

3800 EAST 91ST. STREET • CLEVELAND, OHIO 44105-2197

PHONE: (216) 641-7500 • FAX: (216) 641-0633

NATIONWIDE: 1-800-321-9336

From: Brian Kender

Date: January 8, 2024

RE: WRVA Roof Assemblies

Upper PVC Roof Section (Patients Ward):

The current roof assembly consists of a metal deck, ¼”:12 tapered polyISO insulation & a single ply Sarnafil PCV membrane. The test cut down low at the drain was two layers of 1” polyISO and the high test cut was one layer of 1” & one layer of 2” polyISO. This is to be replaced with a mechanically fastened tapered polyISO assembly and a fully adhered ½” cover board set in Insul-Lock Hr. Two layers of StressBase 120 base sheet + one layer of StressPly

EUV cap sheet set in GreenLock cold adhesive. Flood and gravel top coat with GreenLock at a rate of 5 gallons per square.

Upper Ballasted EPDM Roof Section (Patients Ward):

The current roof assembly consists of a structurally sloped concrete deck with two layers of 1” polyISO and a ballasted EPDM membrane. This is to be replaced with a fully adhered

¼”:12 tapered polyISO assembly and a ½” cover board set in Insul-Lock HR. Two layers of

StressBase 120 base sheet + one layer of StressPly EUV cap sheet set in GreenLock cold adhesive. Flood and gravel top coat with GreenLock at a rate of 5 gallons per square.

Swimming Pool Roof (Lower Elevation):

The current roof assembly consists of a concrete deck with a tapered polyISO insulation assembly and a ballasted EPDM membrane. Test cuts revealed 1.5” of polyISO down low and

3.5” of polyISO up high. This is to be replaced with a fully adhered ¼”:12 tapered polyISO assembly and a ½” cover board set in Insul-Lock HR. Two layers of StressBase 120 base sheet + one layer of StressPly EUV cap sheet set in GreenLock cold adhesive. Flood and gravel top coat with GreenLock at a rate of 5 gallons per square.

Swimming Pool Roof (Upper Elevation):

The current roof assembly consists of a structurally sloped concrete deck with one layer of 2” polyISO and a ballasted EPDM membrane. This is to be replaced with a fully adhered

¼”:12 tapered polyISO assembly and a ½” cover board set in Insul-Lock HR. Two layers of

StressBase 120 base sheet + one layer of KEE – Stone FB 60 cap sheet set in GreenLock cold adhesive.

Swimming Pool Roof (Sloped Elevation):

The current roof assembly consists of a structurally sloped concrete deck with one layer of 2” polyISO and a ballasted EPDM membrane. This is to be replaced with a fully adhered flat stock polyISO assembly and a ½” cover board set in Insul-Lock HR. KEE-Stone FB 60 set in

KEE-Lock Spatter Spray.

Kind Regards, Brian Kender bkender@garlandind.com

617-755-4655

The Garland Company

Boston, MA mailto:bkender@garlandind.com