Text version
D C
B
A
A
A
A
A
A
A SCUPPER
CL
SCUPPER CL
EMBLEM
CL
EMBLEM
CL
A
A
A
A
A
A
A
A
A
E F
G
CAP TYPE, TYP.
SCUPPER
CL
EMBLEM CL
EMBLEM
CL
SCUPPER
CL
SCUPPER
CL
SCUPPER
CL
EMBLEM
CL
EXISTING #5 @ 12"
O.C. VERTICAL
EXISTING #4 @ 12" O.C. EW
1'-0" V.I.F.
CONTINUOUS DRIP
SLOT (BOTH SIDES)
EXISTING
MANUFACTURED STONE
VENEER TO REMAIN.
CONTRACTOR TO
PROTECT EXISTING
MANUFACTURED STONE
FROM CONSTRUCTION
OPERATIONS
EXISTING JUNCTION BOX
NEW STONE WALL
CAP; CENTER ON
WALL
1" DIA. X 2" HOLE TO
RECEIVE NEW PIN
NEW 1/2" X 6" TYPE 304 S.S.
PIN, 2 PINS PER CAP; SET
W/NON-METALLIC
NON-SHRINK GROUT, TYP.
2"2"
+/-3"
TYP.
NOTES:
1. CHIPPED OR DAMAGED
EXISTING STONES SHALL
REQUIRE BORAL CULTURED
STONE MASONRY COSMETICS
EXPERT FOR REPAIRS: RICK
CONNER (419) 295-0134.
2. PROVIDE CLEAN, STRAIGHT,
BACKER ROD AND SEALANT
JOINTS BETWEEN STONE CAPS.
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.
NEW 1/2" MORTAR JOINT,
COLOR TO MATCH
EXISTING
NEW 3/8" BACKER ROD
AND SEALANT JOINTS AT
VERTICAL CAP JOINTS,
TYP.
SERVICE EMBLEMS
THIS SIDE OF WALL
R58'-7" R56'-9"
R56'-10"
R56'-10 12 "
R58'-6"
R58'-5 12 "
4'-6"
2' -0
16"
1" 1"
8"
1"
16"
1"
PLAN - TYPE A
SAWN BLANK EDGE, TYP.
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
DRIP SLOT (BELOW), TYP.
NOTE:
DIMENSIONS PROVIDED BASED ON
RECORD DRAWINGS OF ASSEMBLY
AREA WALL. VERIFY IN FIELD ACTUAL
CONSTRUCTED CONDITION PRIOR TO
SHOP DRAWING SUBMITTAL.
CI760 SIM.
2' -0
1"
11 2" 3 16" 11
8"
5'-3"
16"
16"
R58'-7"
R58'-6"
R58'-5 12 "
R56'-9" R56'-10"
R56'-10 12 "
SAWN BLANK EDGE, TYP.
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
DRIP SLOT (BELOW), TYP.
1" 1"
PLAN - TYPE B
NOTE:
DIMENSIONS PROVIDED BASED ON
RECORD DRAWINGS OF ASSEMBLY
AREA WALL. VERIFY IN FIELD ACTUAL
CONSTRUCTED CONDITION PRIOR TO
SHOP DRAWING SUBMITTAL.
CI760 SIM.
SAWN BLANK EDGE, TYP.
1"
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
DRIP SLOT (BELOW), TYP.
1"
.90°
V.I.F
2' -0
5'-0" 8"
16"
64.10°
V.I.F.90 .00
TYP.
PLAN - TYPE C
NOTE:
DIMENSIONS PROVIDED BASED ON RECORD DRAWINGS OF
ASSEMBLY AREA WALL. VERIFY IN FIELD ACTUAL CONSTRUCTED
CONDITION PRIOR TO SHOP DRAWING SUBMITTAL.
CI760
90.00°TYP.
SAWN BLANK EDGE, TYP.
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
CONTINUOUS DRIP SLOT
(BELOW), TYP.
4'-6"
2' -0
1"
1"
2"
PLAN - TYPE D
NOTE:
DIMENSIONS PROVIDED BASED ON RECORD DRAWINGS OF
ASSEMBLY AREA WALL. VERIFY IN FIELD ACTUAL CONSTRUCTED
CONDITION PRIOR TO SHOP DRAWING SUBMITTAL.
CI760 SIM.
PLAN - TYPE E
CI760 SIM.2" 25
16"
5'-6"
1" 1"
2' -0
11 2" 1"
1'-115 16"
R58'-5 12 "
R58'-6"
R58'-7"
NOTE:
DIMENSIONS PROVIDED BASED ON RECORD
DRAWINGS OF ASSEMBLY AREA WALL. VERIFY IN
FIELD ACTUAL CONSTRUCTED CONDITION PRIOR TO
SHOP DRAWING SUBMITTAL.
R56'-10 12 "
R56'-10"
R56'-9"
SAWN BLANK EDGE, TYP.
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
DRIP SLOT (BELOW), TYP.
2' -0
5'-0"
PLAN - TYPE F
NOTE:
DIMENSIONS PROVIDED BASED ON RECORD DRAWINGS OF
ASSEMBLY AREA WALL. VERIFY IN FIELD ACTUAL CONSTRUCTED
CONDITION PRIOR TO SHOP DRAWING SUBMITTAL.
CI760
1" 1"
8"
2"
.00
TYP.115.90°V.I.F.
.10
V.
I.F
SAWN BLANK EDGE, TYP.
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
DRIP SLOT (BELOW), TYP.
SAWN BLANK EDGE, TYP.
INDIANA LIMESTONE CAP:
COLOR BUFF, HONED
FINISH
CONTINUOUS
DRIP SLOT
(BELOW), TYP.
4'-6"
2' -0
1"
90.00°TYP.
PLAN - TYPE G
NOTE:
DIMENSIONS PROVIDED BASED ON RECORD DRAWINGS OF
ASSEMBLY AREA WALL. VERIFY IN FIELD ACTUAL CONSTRUCTED
CONDITION PRIOR TO SHOP DRAWING SUBMITTAL.
CI760 SIM.
1"
2"
6"
2'-0"
41 2"
R 14 " R
4"
4"
1"
2"
1"
2"
NOTE:
CAP PIECES THAT DO NOT MEET THESE REQUIREMENTS
WILL BE REJECTED AT THE CONTRACTOR'S EXPENSE.
CAP CHIPS LARGE THAN 1/4" DIAMETER WILL BE
REJECTED AT CONTRACTOR'S EXPENSE.
INDIANA LIMESTONE CAP.
COLOR BUFF, FINISH HONED
CONTINUOUS DRIP SLOT,
STRAIGHT AND CONSISTENT
IN DEPTH AND WIDTH, TYP.
3 8" T
YP
MINIMUM TWO (2)
S.S. PINS PER CAP
SAWN BLANK EDGE
1" 1"
WASH
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
OAKLAND COUNTY, MICHIGAN
923PC2006
MAY 10, 2019
GordonPROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
Dwg. of 238
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved:
Phase
Project Director
Building Number
BID DOCUMENTS SUBMISSION
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
GREAT LAKES NATIONAL
CEMETERY
PHASE II DEVELOPMENT
The LA Group
(518) 587-8100
Aqua Engineering, Inc.
(970) 372-6104
OCMI
(202) 607-7575 rvi
(512) 480-0032
Miller-Remick LLC.
(856) 429-4000
MEGA
(517) 223-3512
The Onyx Group
(703) 548-6699
ECS Midwest LLC.
847-279-0366
GIS, Inc.
(205) 941-0442
05/10/2019
ASSEMBLY AREA WALL CAP
REPLACEMENT DETAILS
CI760
KEY MAP
3/16" = 1'-0"
ASSEMBLY AREA CAP PLAN ENLARGEMENT1 0 5'3'1'
NORTH
1" = 1'-0"
CAP SETTING DETAIL2 1'0 6"3"
DLM JDB
ASSEMBLY AREA
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE A3 8"0 4"2"
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE B4 8"0 4"2"
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE C5 8"0 4"2"
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE D6 8"0 4"2"
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE E8 8"0 4"2"
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE F9 8"0 4"2"
1 1/2" = 1'-0"
ASSEMBLY AREA CAP TYPE G10 8"0 4"2"
3" = 1'-0"
ASSEMBLY AREA CAP SECTION7 0 4"1" 2" NORTH
| 98_CS401-402 - Columbarium Site Plan Enlargement-CS401 |
| 98_CS401-402 - Columbarium Site Plan Enlargement-CS402 |
| 100_CG401-402 - Columbarium Grading Enlargement-CG401 |
| 100_CG401-402 - Columbarium Grading Enlargement-CG402 |
| 102_CG403-404 - Columbarium Drainage Enlargement Plans-CG403 |
| 102_CG403-404 - Columbarium Drainage Enlargement Plans-CG404 |
| 104_CI700- Columbarium Numbering Plan-CI700 |
| 105_CI701-703 Columbarium Elevations-CI701 |
| 105_CI701-703 Columbarium Elevations-CI702 |
| 105_CI701-703 Columbarium Elevations-CI703 |
| 108_CI704-708 Columbarium Details-CI705 |
| 108_CI704-708 Columbarium Details-CI704 |
| 108_CI704-708 Columbarium Details-CI706 |
| 108_CI704-708 Columbarium Details-CI707 |
| 108_CI704-708 Columbarium Details-CI708 |
| 113_CI709-710 - Base Stone Location Plan-CI709 |
| 113_CI709-710 - Base Stone Location Plan-CI710 |
| 115_CI711 - Base Stone Details-CI711 |
| 116_CI712-713 - Capstone Location Plan-CI712 |
| 116_CI712-713 - Capstone Location Plan-CI713 |
| 118_CI714-CI715 - Capstone Details-CI714 |
| 118_CI714-CI715 - Capstone Details-CI715 |
| 120_CI750 CSS Service Emblem Details-CI750 |
| 120_CI750 CSS Service Emblem Details-CI751 |
| 122_CI760 Assembly Wall Cap Details-CI760 |
| L-100 |
| L-101 |
| L-102 |
| L-103 |
| L-104 |
| L-105 |
| L-106 |
| L-107 |
| L-108 |
| L-109 |
| L-501 |
| L-502 |
| P-GreatLakesPh2-dd-I-001 |
| Sheets and Views |
| I-001 |
| P-GreatLakesPh2-dd-I-100 |
| Sheets and Views |
| I-100 |
| P-GreatLakesPh2-dd-I-101 |
| Sheets and Views |
| I-101 |
| P-GreatLakesPh2-dd-I-102 |
| Sheets and Views |
| I-102 |
| P-GreatLakesPh2-dd-I-103 |
| Sheets and Views |
| I-103 |
| P-GreatLakesPh2-dd-I-104 |
| Sheets and Views |
| I-104 |
| P-GreatLakesPh2-dd-I-105 |
| Sheets and Views |
| I-105 |
| P-GreatLakesPh2-dd-I-106 |
| Sheets and Views |
| I-106 |
| P-GreatLakesPh2-dd-I-107 |
| Sheets and Views |
| I-107 |
| P-GreatLakesPh2-dd-I-108 |
| Sheets and Views |
| I-108 |
| P-GreatLakesPh2-dd-I-109 |
| Sheets and Views |
| I-109 |
| P-GreatLakesPh2-dd-I-110 |
| Sheets and Views |
| I-110 |
| P-GreatLakesPh2-dd-I-501 |
| Sheets and Views |
| I-501 |
| P-GreatLakesPh2-dd-I-502 |
| Sheets and Views |
| I-502 |
| P-GreatLakesPh2-dd-I-503 |
| Sheets and Views |
| I-503 |
| GLNC_DD Drawings_Bathrooms_onyx-autodesk |
| Sheets |
| A-002 - LIFE SAFETY PLAN |
| AA101 - PIC/ ADMIN BLDG - DEMOLITION PLAN |
| AA102 - PIC/ ADMIN BLDG - DEMOLITION RCP |
| AA103 - PIC/ ADMIN BLDG - DEMOLITION ROOF PLAN |
| AA104 - PIC/ ADMIN BLDG - FLOOR PLAN |
| AA105 - PIC/ADMIN BLDG - REFLECTED CEILING PLAN |
| AA106 - PIC/ ADMIN BLDG - ROOF PLAN |
| AA201 - PIC/ADMIN BLDG – BLDG ELEVATIONS |
| AA301 - PIC/ADMIN BLDG – BLDG SECTIONS |
| AA401 - PIC/ADMIN BLDG – BLDG DETAILS |
| AA402 - PIC/ADMIN BLDG - MEN'S & FAMILY RESTROOM |
| AA403 - PIC/ADMIN BLDG - WOMEN'S RESTROOM |
| AA404 - PIC/ ADMIN BLDG - FIXTURE HEIGHTS & SCHEDULE |
| AA405 - PIC/ ADMIN INTERIOR ELEVATIONS |
| AA501 - PIC/ ADMIN BLDG - DETAILS |
| AA502 - PIC/ ADMIN BLDG - WALL DETAILS |
| AA601 - PIC/ADMIN BLDG - DOOR AND WINDOW SCHEDULE |
| AA602 - PIC/ADMIN PARTITION TYPES |
| AA603 - PIC/ADMIN BLDG – INTERIOR FINISH PLAN |
| AA604 - PIC/ADMIN BLDG – FIXTURE SCHEDULE |
| GLNC_CD_16_onyx-autodesk |
| Sheets |
| A-001 - ARCHITECTURAL SYMBOLS & ABBREVIATIONS |
| AB101 - BULK STORAGE BLDG - FLOOR PLAN & ROOF PLAN |
| AB201 - BULK STORAGE BLDG - BLDG ELEVATIONS & SECTION |
| AB501 - BULK STORAGE BLDG - DETAILS |
| AC101 - COMMITTAL SHELTER - FLOOR PLAN (ADD ALTERNATE NO.1) |
| AC102 - COMMITTAL SHELTER - REFLECTED CEILING PLAN & ROOF PLAN (ADD ALTERNATE NO.1) |
| AC201 - COMMITTAL SHELTER – BLDG ELEVATIONS & SECTIONS (ADD ALTERNATE NO.1) |
| AC401 - COMMITTAL SHELTER – DETAILS (ADD ALTERNATE NO.1) |
| AE101 - EQUIPMENT VEHICLE STORAGE - DEMOLITION PLAN |
| AE102 - EQUIPMENT VEHICLE STORAGE - FLOOR PLAN |
| AE103 - EQUIPMENT VEHICLE STORAGE - MEZZANINE FLOOR PLAN |
| AE104 - EQUIPMENT VEHICLE STORAGE - ROOF PLAN |
| AE105 - EQUIPMENT VEHICLE STORAGE- REFLECTED CEILING PLANS |
| AE301 - MEZZANINE - SECTIONS |
| AE501 - MEZZANINE - DETAILS |
| AF101 - COVERED STORAGE - PLANS (ADD ALTERNATE NO.4) |
| AF102 - COVERED STORAGE - SECTIONS & DETAILS (ADD ALTERNATE NO.4) |
| AG101 - MAINTENANCE GARAGE - TRENCH REPLACEMENT |
| AT101 - PROPOSED TEMPORARY TRAILER & RESTROOM LAYOUT |
| P-001 |
| P-001 |
| P-001 |
| PD101 |
| PD101 |
| PD101 |
| PP100 - Admin site utilities |
| PP100 - Admin site utilities |
| PP100 |
| PP101 |
| PP101 |
| PP101 |
| PP501 |
| PP501 |
| PP501 |
| P-601 |
| P-601 |
| P-601 |
| P-701 |
| P-701 |
| P-701 |
| M-001 |
| M-001 |
| M-001 |
| MD101 |
| MD101 |
| MD101 |
| M-101 |
| M-101 |
| M-101 |
| M-501 |
| M-501 |
| M-501 |
| M-701 |
| M-701 |
| M-701 |
| E-001 |
| E-001 |
| E-001 |
| E-002 |
| E-002 |
| E-002 |
| ED101 |
| ED101 |
| ED101 |
| ES001 |
| ES001 |
| ES001 |
| EL101 |
| EL101 |
| EL-101 |
| EL102 |
| EL102 |
| EL102 |
| EL103 |
| EL103 |
| EL103 |
| EP101 |
| EP101 |
| EP-101 |
| EY101 |
| EY101 |
| EY-101 |
| EL201 |
| EL201 |
| EL-201 |
| EP201 |
| EP201 |
| EP-201 |
| EL301 |
| EL301 |
| EL-301 |
| EL302 |
| EL302 |
| EL302 |
| EL303 |
| EL303 |
| EL303 |
| EL304 |
| EL304 |
| EL304 |
| EP301 |
| EP301 |
| EP-301 |
| EY301 |
| EY301 |
| EY-301 |
| EL401 |
| EL401 |
| EL401 |
| E-501 |
| E-501 |
| E-501 |
| E-502 |
| E-502 |
| E-502 |
| E-601 |
| E-601 |
| E-601 |
| E-602 |
| E-602 |
| E-602 |
| E-701 |
| E-701 |
| E-701 |
| E-702 |
| E-702 |
| E-702 |
| S-001 |
| S-001 |
| S-001 |
| SF101 |
| SF101 |
| SF101 |
| SF111 |
| SF111 |
| SF111 |
| SF112 |
| SF112 |
| SF112 |
| SF121 |
| SF121 |
| SF121 |
| SF131 |
| SF131 |
| SF131 |
| S-501 |
| S-501 |
| S-501 |
| S-502 |
| S-502 |
| S-502 |
| S-503 |
| S-503 |
| S-503 |
| S-504 |
| S-504 |
| S-504 |
| S-505 |
| S-505 |
| S-505 |
| S-506 |
| S-506 |
| S-506 |
| SS301 |
| SS301 |
| SS301 |
| SS302 |
| SS302 |
| SS302 |