32 31 19 05 SITE Security Fencing Shop Drawings and Product Data.pdf

PDF 4 MB Posted

Attached to
Z1DA--554-24-107 Repair RMR North and South Gates and Fencing (VA-24-00029547)
Solicitation number
36C25924R0056
Issued by

About this file

This solicitation requests proposals for security fence and gate repair work at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The selected contractor will replace 11 broken or damaged perimeter fence panels and assemblies, along with an automated sliding entry gate. The contractor must remove and dispose of damaged materials and install new fencing and gate components that meet all material and construction standards. The contractor must also replace associated posts and footing concrete as needed. The period of performance is 120 calendar days, with the gate replacement required within 12 consecutive hours on a weekend. The government will award a firm-fixed-price contract. The contractor must provide safety plans, schedules, and warranties for all work and materials.

View the file

Other files

File Type Posted
S04-554-24-107 Pre-Bid Attendance.pdf PDF
Questions Responded.docx DOCX document
36C25924R0056 0001.docx DOCX document
36C25924R0056.docx DOCX document
North Gate Edge Damage.jpg JPG image
South Entrance Damaged Fence and Pedestrian Gate.jpg JPG image
North Gate Controls Label 1.jpg JPG image
North Entrance Damaged Fence 2.jpg JPG image
EXISTING 323119 - Decorative Metal Fences _ Gates.pdf PDF
013323 Shop Drawings.docx DOCX document
S22- 852.219-75 LOS Certification.docx DOCX document
260511 Requirements for Electrical Installations 02.docx DOCX document
014500 Quality Control.docx DOCX document
32 31 19 09 GEN As Builts Foundation Fence Decorative Metal Fence and Gates.pdf PDF
260511 Requirements for Electrical Installations.docx DOCX document
017419 Construction Waste Management.doc DOC document
013526 Safety Requirements.docx DOCX document
UPDATED 323140 High Security Fences and Gates.docx DOCX document
014500 Quality Control 02.docx DOCX document
010000 General Requirements.docx DOCX document
North Entrance Damaged Fence 1.jpg JPG image
32 31 19 08 GEN O and M Foundation Fence Decorative Metal Fences and Gates.pdf PDF
North Gate Controls Label 2.jpg JPG image
32 31 19 06 SITE Security Fences and Gates Sliding Gates.pdf PDF
014219 Reference Standards.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fax: 303.930.9001

303.930.9000Tel:

Kiewit - Turner a Joint Venture

Suite A-300 7200 S. Alton Way

Englewood, CO 80112

Job: 15387 - Replacement Medical Center Facility

Product Data

Sample

Other

Shop Drawing

Resubmittal

First Submittal X

VA Proj #:

To: H+L Architecture 1755 Blake Street

Suite 400

Denver, CO 80202

DESCRIPTIONSpecificationSUBMITTAL

ItemQuantity Section Sub./SupplierNo. Mfgr.

ACTION

DCBA E

Kiewit Submittal No. 22 13 00-01 Architect's Submittal No. 00008

Review Cycle: 001

Attn: Chuck Adkisson

1 SWPPP - CBS & RFP #3 OnlyKiewit - Turner a

Joint Venture

01 573

ACTION TAKEN

CONTRACTOR'S SIGNATURE:

CONTRACTOR'S NOTES:

DATE: 7/12/2011

Reviewed Only for Revisions to

Reviewed: Incorporate Changes

Reviewed=

A

B

C

Previous Submittal

Revise and Resubmit=D

Rejected =E

ARCHITECT/ENGINEER RESPONSE:

REMARKS:

BY: DATE:

Expedition f_sb_pks_01a

VA101CFM-C-0100

Cc: Tim Pogany, U.S. Dept. of Veterans Affairs

Received By ___________________

Date _______________

32 31 19

X

SITESecurity Fencing Shop Drawings and Product Data

X

Nasatka Barrier, Inc.

32 31 19005

01/06/2017

01/20/2017

Kiewit-Turner Submittal No.

COE 1

REQUESTED RETURN DATE:

Kevin Lindsey, U.S. Dept. of Veterans Affairs

VA101F-15-C-0005

13611 E. Colfax Avenue 2nd Floor Aurora, CO 80045

DEPARTMENT OF THE ARMY

Omaha District Corps of Engineers 13611 East Colfax Avenue 2nd Floor Aurora, CO 80045

W9128F-16-C-0003

Peter Sturdivant

KIEWIT-TURNER

a Joint Venture

☐ REVIEWED – NO COMMENTS MADE

☐ REVIEWED WITH COMMENTS

☐ RESUBMITTAL REQUIRED

DATE ___________ SIGNED ___________________________

SUBMITTAL # __________________________________

These shop drawings / submittals have been review in accordance with the provisions of the Contract Documents.

Kiewit-Turner’s review shall not serve to relieve

Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.

1/5/17

32 31 19-005

X

Kiewit-Turner a Joint Venture

7200 S. Alton Way, Suite A-300, Englewood, CO 80112

Phone: 303-930-9000 FAX: 303-930-9001

Project Name:

Subcontractor Name: Submittal Date:

Contact Name: E-mail: Return By Date:

Contact Phone(s): Review Days:

Number: Name:

1.4 N/A Y Y Y Y

1.4 N/A Y Y Y Y

1.4 N/A Y Y Y Y

1.4 N/A Y Y Y Y

1.4 Double Swing Gate Shop Drawings N/A Y Y Y Y

Ornamental Fence Product Data

1.4 Tamper Resistant Screws Product Data N/A Y N Y Y

1.4 Powder Coat System Product Data N/A Y Y Y Y

1.4 Perforated Metal Product Data N/A Y N Y Y

1.4 Concrete Mix Design and Product Data N/A Y N Y N

1.4 N/A Y N Y N

1.4 N/A Y N Y N

X

Non-Shrink Grout Product Data

Rebar Mill Certifications

Type I Fence Shop Drawings Hercules Fence

Type III Fence Shop Drawings

Single Swing Gate Shop Drawings

Hercules Fence

Hercules Fence

Reviewed By Date

SWD Inc.

Tiger Drylac USA

McNichols

Matt Muniz for Nasatka 1/5/2016

Submittal is in Compliance

Submittal is in Compliance with Variances from Specifications

Signature

SUBMITTAL INDEX & COVER SHEET

Department of Veteran's Affairs

Replacement Medical Center

Nasatka Barrier, Inc. 01/06/16

Larry Rojas Larry.Rojas@Nasatka.com 01/20/16

(813) 421-3127

Specification Section: 32 31 19 Decorative Metal Fences And Gates

S p e c

S u b m it ta l

P a ra g ra p h

S p e c

P ro d u c t

P a ra g ra p h

S p e c if ie d o r L is te d

M a n u fa c tu re r?

M e e ts

A ll

S p e c

R e q u ir e m e n ts

E x c e p ti o n s o r

V a ri a n c e s f ro m S p e c

A p p ro v e r

In fo rm a ti o n

N e e d e d

I n

T h is P a c k a g e

Submittal Type

Submittal Item Description Manufacturer

Hercules FenceType II Fence Shop Drawings

Ornamental Fence Shop Drawings

Hercules Fence

SubmittalIndexForm_041009 Page 1 of 1 mailto:Larry.Rojas@Nasatka.com

SUBMITTAL PACKAGE REV 002

Project:

Submitted To:

Matt Muniz Structural Engineering Manager

Replacement Medical Center Facility Eastern Colorado Health Care System

KIEWIT-TURNER A JOINT VENTURE

13611 E. Colfax Ave., 2nd Floor, Aurora, CO 80045 cell 907-351-8348 fax 720-367-5353 matt.muniz@kiewitturner.com www.denvervahospital.com

Submitted By:

Corey Swickle High Security | Project Manager/Estimator

Hercules Fence of MD, LLC 8580 Mission Road, Jessup, MD 20794

C| 443.602.2173 E| Corey.Swickle@herculesfence.com

P| 410.799.1555

F| 410.799.0008

Date Submitted:

December 19th, 2016

December 27th, 2016

Date Submitted:

December 19th, 2016 December 27th, 2016

“Security in Every “Quality Craftsmanship in Every J“Security in Every Job” mailto:matt.muniz@kiewitturner.com http://www.denvervahospital.com/ mailto:Corey.Swickle@herculesfence.com

Table of Contents

“Security in Every

Job”

“Quality Craftsmanship in Every Job”

“Security in Every Job”

Since 1955

Cover Page (1 page)

Table of Contents (1 page)

Ornamental Fence Details (4 pages)

Tamper Resistant Screws - Product Data ( 3 pages)

Ornamental Single Swing Gate & Hinges (10 pages)

Ornamental Double Swing Gate & Hinges ( 3 pages)

Gate Hardware ( 22 pages)

Layout Drawing per RFP 0045 ( 1 page)

Ornamental Fence Shop Drawings (4 pages)

Ornamental Single Swing Gate Detail (2 pages)

Ornamental Double Swing Gate Detail (2 pages)

Temper Resistant Screws Product Data (2 pages)

Powder Coat System Product Data (10 pages)

Perforated Metal Panel Product Data (3 pages)

G6R

GATE HARDWARE

Ornamental Fence Details Type 1, Type 2 & Type 3

Ornamental Fence Shop Drawings:

Type 1, Type 2, & Type 3

TYPE 1 FENCING STEP & LEVEL ELEVATION

1/8"=1'-0"

12 3/4"

68" I.D.

16 3/16"

3"

97 11/16"

96" MIN.

TYPE 1 FENCING STEP & LEVEL ELEVATION

3/4"=1'-0"

3"x3"x3/16" STEEL TUBING POST

42"

6"

138"+/-

Ø12"x48" DEEP CROWNED CONCRETE

FOOTING SET FLUSH WITH GRADE

POST SECTION

100" 100"

NOTE: DRAWN AS 1° SLOPE.

3" 4 11/16"

NOTES:

3/4"=1'-0"

3/4"x1 1/2" SOLID STEEL HORIZONTAL

MEMBER MECHANICALLY FASTENED

TO THE TUBING POST

3/4"x3/4" SOLID STEEL PICKETS ARE

FACE WELDED TO THE HORIZONTAL

BAR @ 5" O.C. MAXIMUM. WELDS WILL

BE ON ALL FOUR SIDES WHERE THE

PICKET CONTACTS THE HORIZONTAL.

1 PANEL/POST ATTACHMENT

3"=1'-0"2

PANEL/POST ATTACHMENT

3"=1'-0"3

3"x3"x3/16" STEEL TUBING POST

3"x3"x3/16" STEEL TUBING POST

3/4"x3/4" SOLID STEEL PICKETS FACE

WELDED TO THE HORIZONTAL BAR

AND ALIGNS WITH THE FACE OF THE

3" POST

3/4"x1 1/2" SOLID STEEL HORIZONTAL

MEMBER IS SECURED BY A BRACKET

(2) TAMPER-PROOF SCREWS ATTACHES

THE BRACKET TO THE POST

3/4"x1 1/2" SOLID STEEL HORIZONTAL

11 GA. BENT STEEL ANGLE

3" PRESSED POST CAP (TYP)

SURFACE PREPARATION AND COATING OF STEEL PANELS AND POSTS: ALL SURFACES TO BE SAND BLASTED TO NEAR WHITE; WASH STEEL WITH CRYSCOATE (IRON PHOSPHATE) 2147; SEAL WITH GARDOBOND AP 9811;

THERMALLY APPLY 2-3 MILS OF TIGER DRYLAC SERIES 69 - DRYZINC PRIMER; THERMALLY APPLY 2-3 MILS OF

TIGER DRYLAC SERIES 38 "SUPER DURABLE" BLACK SEMI-GLOSS FINISH COAT.

STEP AND LEVEL PANEL LENGTHS MAY BE SHORTER THAN SHOWN IN ORDER TO LIMIT THE GAP BETWEEN THE FENCE AND FINISHED GRADE IN AREAS WITH INCREASED SLOPE. ARCHITECT TO CONFIRM MAXIMUM

ACCEPTABLE CLEARANCE.

12"

69 1/2" O.D.

11 1/2"

14 GA. BENT STEEL BRACKET

TAMPER-PROOF FASTENERS ARE 1/4-20 x 3/4" PAN HEAD T30 SIX LOBE TRI ROUND THREAD FORMING SCREWS

WITH A MAGNI BLACK FINISH.

14 GA. STEEL BENT BRACKET ON AN

11 GA. BENT ANGLE MECHANICALLY

FASTENED TO THE POST W/ (2)

TAMPER-PROOF SCREWS

2"x1"x14 GA. STEEL BRACKET

11 GA. BENT STEEL ANGLE

Drawn by:

Date:

Scale:

D.L.M.

36 W. PENNSYLVANIA AVENUE

WALKERSVILLE, MD 21793

1-800-331-2590

HERCULES CUSTOM IRON, LLC

AN AFFILIATE OF HERCULES FENCE

SHEET NO.

8-15-2016

AS SHOWN

REPLACEMENT MEDICAL CENTER FACILITY

EASTERN COLORADO HEALTH CARE SYSTEM

AURORA, COLORADO

TYPE 1 FENCING - STEP & LEVEL PANELS

REVISIONS:

11-2-2016: RUNNER SPACING

12-16-2016: PANEL ATTACHMENT FASTENERS

SL-1

No fasteners shown attaching fence panel to bracket. Subcontractor to fasten horizontal rails to steel bracket.

No steel reinforcement shown in concrete foundations. Reinforcement shown in contract drawings, and required by specification. If Subcontractor proposes cost savings by deleting reinforcement, provide a credit proposal for review. Deletion of footing reinforcement was not discussed during RFP 45 conference calls.

Top of domed concrete footings to be 3" above grade.Gap between finish grade and bottom of fence pickets to be 3" +/- 3" (0-6").

100"

PERIMETER TYPE 2 FENCE ELEVATION SECTION

1"=1'-0" 1"=1'-0"

100"

96"

42"

3/4"x3/4" SOLID STEEL PICKET @ 5" O.C. MAX

3"x3"x3/16" STEEL TUBING POST SET FLUSH WITH THE

FACE OF THE WALL CAP

14 GA. STEEL BENT BRACKET ON AN 11 GA. BENT

ANGLE MECHANICALLY FASTENED TO THE POST

W/ (2) TAMPER-PROOF SCREWS

3/4"x1 1/2" SOLID STEEL RUNNERS TOP & BOTTOM

4 7/8" O.C.

PERIMETER TYPE 2 FENCE PLAN

1"=1'-0"

42"

54"

96"

12"

36" O.D.

6"

1 1/2"x1 1/2" SOLID STEEL FENCE SUPPORT BRACKETS

WELDED TO THE BACK OF POST AND SET IN A CORE

DRILLED HOLE WITH NON-SHRINK GROUT

4 7/8" O.C.

10 1/2"

24"

NOTES:

SURFACE PREPARATION AND COATING OF STEEL PANELS AND POSTS: ALL SURFACES TO BE SAND BLASTED TO NEAR WHITE; WASH STEEL WITH CRYSCOATE (IRON PHOSPHATE) 2147; SEAL WITH GARDOBOND AP 9811;

THERMALLY APPLY 2-3 MILS OF TIGER DRYLAC SERIES 69 - DRYZINC PRIMER; THERMALLY APPLY 2-3 MILS

OF TIGER DRYLAC SERIES 38 "SUPER DURABLE" BLACK SEMI-GLOSS FINISH COAT.

TAMPER-PROOF FASTENERS ARE 1/4-20 x 3/4" PAN HEAD T30 SIX LOBE TRI ROUND THREAD FORMING

SCREWS WITH A MAGNI BLACK FINISH.

12"

1 1/2"x1 1/2" SOLID STEEL FENCE SUPPORT BRACKETS

WELDED TO THE BACK OF POST AND SET IN A CORE

DRILLED HOLE WITH NON-SHRINK GROUT

Drawn by:

Date:

Scale:

D.L.M.

36 W. PENNSYLVANIA AVENUE

WALKERSVILLE, MD 21793

1-800-331-2590

HERCULES CUSTOM IRON, LLC

AN AFFILIATE OF HERCULES FENCE

SHEET NO.

1-19-2015

AS SHOWNA2.0

REPLACEMENT MEDICAL CENTER FACILITY

EASTERN COLORADO HEALTH CARE SYSTEM

AURORA, COLORADO

TYPE 2 FENCING COMPONENT REVISION

REVISIONS:

12-16-2016: PANEL DESIGN & ATTACHMENT

Submit non-shrink grout product data for approval.

No fasteners shown attaching fence panel to bracket. Subcontractor to fasten horizontal rails to steel bracket.

PERIMETER TYPE 3 FENCE ELEVATION PANEL SECTION

12 3/4"

68" I.D.

12 1/4"

3"

96"

100"

A1

1"=1'-0" 1"=1'-0"

1"=1'-0"

POST LUG DETAIL

3"=1'-0"1

@ SEASONAL DRAINAGE WAY

PERIMETER TYPE 3 FENCE PLAN

93"

3/4"x1 1/2" SOLID STEEL RUNNER

3"x3"x3/16" STEEL TUBING POST

3/4"x3/4" SOLID STEEL PICKET

@ 5" O.C. MAX

3"x3"x3/16" STEEL TUBING POST

3/4"x3/4" SOLID STEEL PICKET @ 5" O.C. MAX

Ø12"x48" DEEP CROWNED CONCRETE

FOOTING SET FLUSH WITH GRADE

14 GA. STEEL BENT BRACKET ON AN

11 GA. BENT ANGLE MECHANICALLY

FASTENED TO THE POST W/ (2)

TAMPER-PROOF SCREWS

3/4"x1 1/2" SOLID STEEL RUNNERS TOP & BOTTOM

NOTES:

14 GA. STEEL BENT BRACKET ON AN

11 GA. BENT ANGLE MECHANICALLY

FASTENED TO THE POST W/ (2)

TAMPER-PROOF SCREWS

SURFACE PREPARATION AND COATING OF STEEL PANELS AND POSTS: ALL

SURFACES TO BE SAND BLASTED TO NEAR WHITE; WASH STEEL WITH

CRYSCOATE (IRON PHOSPHATE) 2147; SEAL WITH GARDOBOND AP 9811;

THERMALLY APPLY 2-3 MILS OF TIGER DRYLAC SERIES 69 - DRYZINC

PRIMER; THERMALLY APPLY 2-3 MILS OF TIGER DRYLAC SERIES 38 "SUPER

DURABLE" BLACK SEMI-GLOSS FINISH COAT.

TAMPER-PROOF FASTENERS ARE 1/4-20 x 3/4" PAN HEAD T30 SIX LOBE TRI

ROUND THREAD FORMING SCREWS WITH A MAGNI BLACK FINISH.

4 7/8" O.C.

Drawn by:

Date:

Scale:

D.L.M.

36 W. PENNSYLVANIA AVENUE

WALKERSVILLE, MD 21793

1-800-331-2590

HERCULES CUSTOM IRON, LLC

AN AFFILIATE OF HERCULES FENCE

SHEET NO.

1-19-2015

AS SHOWNA3.0

REPLACEMENT MEDICAL CENTER FACILITY

EASTERN COLORADO HEALTH CARE SYSTEM

AURORA, COLORADO

TYPE 3 FENCING COMPONENTS

REVISIONS:

11-2-2016: RUNNER SPACING

12-16-2016: PANEL ATTACHMENT BRACKETS

Subcontractor to ensure min. spacing between horizontal rails is 5'-8", similar to Type I fence.

No fasteners shown attaching fence panel to bracket. Subcontractor to fasten horizontal rails to steel bracket.

No steel reinforcement shown in concrete foundations. Reinforcement shown in contract drawings, and required by specification. If Subcontractor proposes cost savings by deleting reinforcement, provide a credit proposal for review. Deletion of footing reinforcement was not discussed during RFP 45 conference calls.

Subcontractor to field measure prior to fabrication. Swales between 6' and 7' wide.

Top of domed concrete footings to be 3" above grade.

Gap between finish grade and bottom of fence pickets to be 3" +/- 3" (0-6").

Ornamental Gate Detail Single Gate & HingesSingle Gate

40 3/4" O.D.

SECTIONPERIMETER PEDESTRIAN GATE ELEVATION

TYPE 1 FENCE

3/4"x3/4" SOLID STEEL PICKETS ARE FACE

WELDED TO HORIZONTALS @ 5" O.C. MAX

4"x4"x3/16" STEEL TUBING POST THAT

DOUBLES AS THE ELECTRICAL CHASE

3/4"x3" STEEL FLAT BAR GATE SIDES (TYP)

PEDESTRIAN GATE PLAN

D&D TECHNOLOGIES HYDRAULIC

SELF-CLOSING HINGE

45 1/2" O.C.

DETEX 10xW SERIES WEATHERIZED

RIM EXIT DEVICE

DETEX O3C(N) TRIM PLATE

W/ LOCK & PULL

2"x10" STEEL TUBING FOR

MOUNTING EXIT DEVICES

96"

12 3/4"

68" I.D.

12 1/4"

1"=1'-0" 1"=1'-0"

5" O.C.

1"=1'-0"

3/4"x2 1/4" STEEL SOLID BAR HORIZONTAL

WELDED TO THE GATE SIDES (T & B)

Ø16"x48" DEEP CROWNED CONCRETE FOOTER

SET FLUSH WITH FINISHED GRADE

4" STEEL PRESSED CAP

4"x3"x3/16" STEEL TUBING HEADER WELDED

TO THE POSTS FOR A PRE-HUNG SYSTEM

6"

1" SOLID SQUARE STEEL BAR WELDED

TO THE POSTS BELOW GRADE FOR A

PRE-HUNG SYSTEM

11 GA. ALUM. PERFORATED SHEET WITH 1"

ROUND ON A 1-1/4" STAGGERED PATTERN

MECHANICALLY FASTENED TO THE GATE

AND FENCE PANELS

NOTES:

SURFACE PREPARATION AND COATING OF STEEL PANELS AND POSTS: ALL SURFACES TO BE SAND BLASTED TO NEAR WHITE; WASH STEEL WITH CRYSCOATE (IRON PHOSPHATE) 2147; SEAL WITH GARDOBOND AP 9811;

THERMALLY APPLY 2-3 MILS OF TIGER DRYLAC SERIES 69 - DRYZINC PRIMER; THERMALLY APPLY 2-3 MILS

OF TIGER DRYLAC SERIES 38 "SUPER DURABLE" BLACK SEMI-GLOSS FINISH COAT.

TAMPER-PROOF FASTENERS ARE 1/4-20 x 3/4" PAN HEAD T30 SIX LOBE TRI ROUND THREAD FORMING

SCREWS WITH A MAGNI BLACK FINISH.

THE DETEX 81-800 POWER SUPPLY BOX FOR GATE OPERATION WILL BE SUPPLIED BY HERCULES FENCE, BUT

THE INSTALLATION PROCESS WILL BE PERFORMED BY OTHERS.

14 GA. STEEL BENT BRACKET ON AN

11 GA. BENT ANGLE MECHANICALLY

FASTENED TO THE POST W/ (2)

TAMPER-PROOF SCREWS

4 7/8" O.C.

Ø1-1/2" HOLE IN EACH POST WITHIN

HEADER FOR WIRING ACCESS

Drawn by:

Date:

Scale:

D.L.M.

36 W. PENNSYLVANIA AVENUE

WALKERSVILLE, MD 21793

1-800-331-2590

HERCULES CUSTOM IRON, LLC

AN AFFILIATE OF HERCULES FENCE

SHEET NO.

1-19-2015

AS SHOWNA1.3

REPLACEMENT MEDICAL CENTER FACILITY

EASTERN COLORADO HEALTH CARE SYSTEM

AURORA, COLORADO

TYPE 1 SINGLE GATE COMPONENTS

8-17-2016 9-1-2016 12-16-2016

REVISIONS:

Subcontractor to ensure min. spacing between horizontal rails is 5'-8", similar to Type I fence.

No fasteners shown attaching fence panel to bracket. Subcontractor to fasten horizontal rails to steel bracket.

No steel reinforcement shown in concrete foundations. Reinforcement shown in contract drawings, and required by specification. If Subcontractor proposes cost savings by deleting reinforcement, provide a credit proposal for review. Deletion of footing reinforcement was not discussed during RFP 45 conference calls.

Top of domed concrete footings to be 3" above grade.

Gap between finish grade and bottom of fence pickets to be 3" +/- 3" (0-6").

Subcontractor to coordinate with security and electrical contractors to ensure steel tube posts provide enough room for electrical wiring.

Perforated sheet to be same color as fencing.

DOUBLE GATE

HEAVY DUTY

BLOCK HINGES

Double Gate & HingesDouble Gate

SECTIONPERIMETER DOUBLE GATE ELEVATION

TYPE 1 FENCE

81 3/4" O.D.

40 3/4" O.D. 40 3/4" O.D.

96"

12 3/4"

68" I.D.

12 1/4"

3/4"x3/4" SOLID STEEL PICKET @ 5" O.C. MAX

3/4"x2 1/4" STEEL SOLID BAR HORIZONTAL

WELDED TO THE GATE SIDES

4"x4"x3/16" STEEL TUBING POST

7" STEEL BLOCK HINGE W/ THE MALE HALF

WELDED TO THE POST AND THE FEMALE

HALF WELDED TO A 1/2"x5"x4-11/16" PLATE

3/4"x3" SOLID STEEL FLAT BAR

GATE SIDES (TYP)

Ø5/8" DROP ROD ASSEMBLY WITH THE

OPTION OF LOCKING WITH A PADLOCK

PERIMETER DOUBLE GATE PLAN

1"=1'-0" 1"=1'-0"

1"=1'-0"

87" O.C.

5" O.C. TYP

Ø16"x48" DEEP CROWNED CONCRETE FOOTER

SET FLUSH WITH FINISHED GRADE

87" O.C.

3/4"x2 1/4" STEEL SOLID BAR HORIZONTAL

WELDED TO THE GATE SIDES

4" STEEL PRESSED CAP

CUSTOM SLIDE BOLT LATCH THAT DOUBLES

AS A GATE STOP

NOTES:

SURFACE PREPARATION AND COATING OF STEEL PANELS AND POSTS: ALL SURFACES TO BE SAND BLASTED TO NEAR WHITE; WASH STEEL WITH CRYSCOATE (IRON PHOSPHATE) 2147; SEAL WITH GARDOBOND AP 9811;

THERMALLY APPLY 2-3 MILS OF TIGER DRYLAC SERIES 69 - DRYZINC PRIMER; THERMALLY APPLY 2-3 MILS

OF TIGER DRYLAC SERIES 38 "SUPER DURABLE" BLACK SEMI-GLOSS FINISH COAT.

TAMPER-PROOF FASTENERS ARE 1/4-20 x 3/4" PAN HEAD T30 SIX LOBE TRI ROUND THREAD FORMING

SCREWS WITH A MAGNI BLACK FINISH.

14 GA. STEEL BENT BRACKET ON AN

11 GA. BENT ANGLE MECHANICALLY

FASTENED TO THE POST W/ (2)

TAMPER-PROOF SCREWS

4 7/8" O.C.

Drawn by:

Date:

Scale:

D.L.M.

36 W. PENNSYLVANIA AVENUE

WALKERSVILLE, MD 21793

1-800-331-2590

HERCULES CUSTOM IRON, LLC

AN AFFILIATE OF HERCULES FENCE

SHEET NO.

1-19-2015

AS SHOWNA1.2

REPLACEMENT MEDICAL CENTER FACILITY

EASTERN COLORADO HEALTH CARE SYSTEM

AURORA, COLORADO

8-17-2016

TYPE 1 DOUBLE GATE COMPONENTS

9-1-2016 12-16-2016

REVISIONS:

Subcontractor to ensure min. spacing between horizontal rails is 5'-8", similar to Type I fence.

No fasteners shown attaching fence panel to bracket. Subcontractor to fasten horizontal rails to steel bracket.

No steel reinforcement shown in concrete foundations. Reinforcement shown in contract drawings, and required by specification. If Subcontractor proposes cost savings by deleting reinforcement, provide a credit proposal for review. Deletion of footing reinforcement was not discussed during RFP 45 conference calls.

Top of domed concrete footings to be 3" above grade.

Gap between finish grade and bottom of fence pickets to be 3" +/- 3" (0-6").

Subcontractor to ensure that double gate isn't removable without the use of tools.

Subcontractor allowed to use barrel hinges.

Barrel hinges may be more economical, and will require less touch-up of coatings in the field.

Ornamental Gate Details

Single & Double Tamper Resistant Screws

Product Data Fence Accessory

Product Data Subcontractor to ensure all products are BAA compliant.

Subcontractor to submit mix-design and product data of concrete to be used.

Submit non-shrink grout product data for approval.

Ornamental Gate Details

Single & Double Tamper Resistant Screws

Product Data

P H O N E : ( 6 3 0 ) 5 4 3 - 3 0 0 3 F A X : ( 6 3 0 ) 5 4 3 - 3 0 2 89 1 0 S . S T I L E S D R . A D D I S O N , I L 6 0 1 0 1 www.swdinc.com

ISO 9001:2008

951-01

TESTING LAB

565 FASTENER

COATING

PERFORMANCE DATA:

Coating thickness 5-8 microns (topcoat) over 8-10 microns (basecoat)

Coefficient of friction

ISO 16047:

0.13 ± 0.03

(other levels available)

Color Gray; silver

(other colors available)

Cyclic corrosion resistance

GM9540P:

60 cycles

SAEJ2334:

120 cycles

Volvo VCS

1027, 149: TBD

Salt spray

ASTM B117: 480-1,000 hours

OEM SPECIFICATIONS:

Amonix 90400026

Arvin Meritor P91

ASTM F2833, Grade 1

BAE Systems 3000009

Bobcat PS106A

Case New Holland MAT0320, Type 1, Class A

Chrysler PS-10378, PS-10633

Cummins 74045

Daimler-Benz DBL8440.20/.22

Delphi DX44501804, DX45501804, DX551801, Denso DDS6700-008 Dometic 12-67 E2 Fiat 9.57513/Tipo IV Ford WSS-M21P37-A1 (S439)

GE F69A4

Genie Terex GES 1326

General Motors GMW 3359, GM 7114M

Honda HES D2008-1

ISO 10683

JLG 4150701

John Deere JDM F13

Land Rover LRES.21.ZS.05

International Truck TMS-4518, Type I

Nissan NESM4601

Porsche PTL 7529

PSA B15 3320

Renault Trucks 01.71.4002/H

Tacom/US Army 12469117

Tesla TM-0010F-M

Thermo-King TKS 10-002

Trane S 3201063A1

TRW Automotive TS 2-25-60, Class A

Volkswagen TL 233 Ofl-t330/Ofl-t350/Ofl-t650

Volvo VCS5737.29, .19

Magni 565 is a chrome-free duplex coating that combines an inorganic zinc-rich basecoat with an aluminum-rich organic topcoat. Formulated as a two-coat system and resistant to automotive fuels and fluids, Magni 565 is the preferred fastener coating of leading global automotive manufacturers. It provides superior corrosion protection and cost-effectiveness and is typically applied to externally threaded fasteners, stampings and other hardware.

• A pplied via dip-spin or spray application methods

• A lleviates hydrogen embrittlement concerns

• E xcellent bimetallic corrosion resistance

• Paintable

• RoHS, WEEE and ELV compliant

Topcoat: Black

Not this fastener.

SINGLE GATE

HYDRAULIC

SELF CLOSING HINGES

TIGER SERIES 69 DRYZINC ZINC-RICH

PRIMERT

AND

TIGER SERIES 38 - SUPER DURABLE

POLYESTER POWDER COATING

SERIES 69 - DRYZINC® ZINC-RICH PRIMER (69/90500)

Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield® system. Designed to impart superior corrosion protection to steel substrates.

Typical applications

•Steelconstructions.
•Stadiumseating.
•Agriculturalmachinery.
•Industrialequipment.
•Fixtures.
•Fences.
•Bikemounts.
•Heavycorrosionprotection.
Standard Packaging 44lb(20kg)box.
5lb(2.5kg)minipack.

Specific Gravity

(ASTM D792)

approximately2.2g/cm3
dependingonpigmentation.
Theoretical Coverage at2.2specificgravityand
2.5mils(60µm)filmthickness:

24 ft2/lb (4.0 m2/kg).

Referalsotothelatestedition
of“TheoreticPowderCoating
CoverageChart”.
Version00-1001(imperial).
Version00-1000(metric).
Storage Stability 6monthsatnomorethan
77°F(25°C).

Features

•Zinc-richprimer.
•Especiallysuitedforblastedsubstrates.
•Goodintercoatadhesion.
•Verygoodcorrosionprotection.
•Verygoodmechanicalproperties.
•Goodchemicalresistance.
•Goodstoragestability.
•Verygoodedgecoverage.

Finish and Color

TIGER Shield®

TIGERShield®isatwo-coatsystemconsistingofacorrosion
protectiveprimerasabasecoat:
•TIGERDryprotector69/70000,
•orTIGERDryzinc®69/90500,
•orTIGERDrylac®zinc-freeOGF09/73841,
andanopaqueweatherresistantTIGERDrylac®powder

coating.

page 1 of 5 Version 02-14Data Sheet 69-1002

Product Data Sheet

TI

G E R D ry la c U .S .A In c.

S w en so n A ve nu e | S t C ha rle s, IL

T

F of fic e.

us tig er -c oa tin gs .u s | w w w .ti ge r-co at in gs .u s

• Grey smooth flow glossy surface, approximately 70±5*.

* Gloss level according to ASTM 523 at 60° angle.

2-coat system: Fence Panels sand-blasted after fabrication, primer coat applied, and the finish coat. (5-6 mils total)

Twomethodsofpretreatmenthavebeentested.Aprerequisite
forinclusionintheTIGERShield®processingisthequalityof
thesteelsubstratedefinedasanalloy-treatedsteel,classST37,
ST52oranyotherequallysuitedsteelthatcanbecoated
(stainlesssteelalloys,anyderivativesthereofaswellas
galvanizedworkpiecesareexplicitlyexcludedforusewithina
TIGERShield®application).
Thefollowingmeansofpretreatmentandmetalpreparation
havebeentestedrespectively,andapproved,inaccordance
withtherequirementsassetforthinENISO12944.

I. Zinc phosphating Minimum conversion coating weight 2.5±1.0 g/m2.

II.) Blasting

Therawsteelsurfaceneedstobeblastedusingsharpand
edgedmineralsorcastironpellets.Thetolerancesforablasted
steelsurfacetherebyneedtocorrespondtothecomparison
specimenstandardG201(lowertolerancesegment2,upper
tolerancesegment3=mediumgrade)andtothesurface
preparationclassofminimumSa2.5accordingtoISO8503-1
andISO8503-2withthesurfacedepthbetweenaminimumof
Rz1.96-2.75mils(50–70µm)andamaximumofRmax3.93mils
(100µm)accordingtoISO8501andapeakamountPc0.39mils
(10µm)of20measuredwithaperthometer(Mahr).Blastingmust
ensurethataminimumof95%ofthetotalareatobeblasted
isreached.
Toavoidanycorrosion,thepowdercoatinghastotakeplace
immediatelyaftertheblastingstage.

Pretreatment (alternatives)

Processing

Corona

Tribo*

*ForTribo/Airstaticpowdercoatingspleaseconfirmbefore
ordering.SuitabilityofmetalliceffectsforTriboprocessing
mustbeverifiedpriortoapplication.Pleaserefertothelatest
editionoftherelevantInformationSheets.
Sincenotallpowdercoatingsaresuitableforrecycling/
reclaim,pleaseverifybeforeordering.

Cure Parameters (substrate temperature)

TIGER Drylac® Two-Coat Process Cure Parameters | Base Coat

Substrate temperature versus curing time

Toachieveafullcureandthedesiredmechanical
propertiesandweatherabilitythetime/temperature
combinationmustfallwithinthecurewindow.

Two-Coat Process

Ifusedasatwo-coatTIGERShield®system,bestintercoat
adhesionisachievedwhenpre-gellingtheprimerat392°F
(200°C)for2-3minutespriortoapplyingaTIGERDrylac®
powdercoatingtopcoat.Itisthentobecured,applyingthe
curingparametersasgivenintherelevantProductData
Sheetforthattopcoat.
Toavoideventualoxidationnomorethan12hours
mustelapsebetweentheapplicationofTIGERDryzinc®
69/90500andthesprayingofanyTIGERDrylac®topcoat.
Whenthepre-gellingandsubsequentcureisdoneina
directlyfiredgasoven,intercoatadhesionbetweenthe
primerandthetopcoatmaysufferduetoavariationinthe
gassupply.

Series 69 - DRYZINC® Zinc-Rich Primer (69/90500) page 2 of 5 Version 02-14Data Sheet 69-1002TI G E R D ry la c U .S .A In c.

S w en so n A ve nu e | S t C ha rle s, IL

T

F of fic e.

us tig er -c oa tin gs .u s | w w w .ti ge r-co at in gs .u s

Formetallicfinishes,itisrecommendedtoobservetheguidelinespublishedinthelatesteditionofTIGERDrylac®“Application
guidelinesformetalliceffectpowdercoatings”.
Topcoatingwithaclearexteriorgradepowdercoatingoveraninteriorgradepowdercoatingdoesnotresultintoaweather
resistantcoatingsystem.

Post-bending properties of any part must be verified prior to application. Minor cracks in the coated surface may lead to corrosion.

Jointsealantsandanyotherauxiliaryproducts,suchasglazingaids,glidingwaxes,drillingandcuttinglubricants,whichcomein
contactwiththecoatedsurface,mustbepH-neutralandfreeofsubstancesthatmaydamagethefinish.Therefore,asuitability
testattheapplicator’send,priortocoating,ishighlyrecommended.

In general, colors in the red, orange and yellow range may require an increased film thickness to achieve full hiding.

Anypost-mechanicalprocessingofalreadycoatedparts,suchassawing,drilling,milling,cuttingandbendingwillresultin
damageofthecoatedsurfaceandwillsubsequentlyweakenthecorrosionprotection.

Please read and understand the Material Safety Data Sheet (MSDS) before use.

Please Note

Film Thickness

Aminimumfilmthicknessof2.5mils(60µm)perlayerneedstobeapplied.Thesystemrequirestheprimer;eitherTIGER
Dryzinc®69/90500orTIGERDryprotector69/70111,tobeappliedat2.5-4.0mils(60-100µm)andtheweatherresistant
topcoattobesprayedatafilmthicknessof2.5-4.0mils(60-100µm).Itisrequiredthatthetotalfilmthicknessofboth;
theprimerandthetopcoat,amounttoanentirefilmbuildupto5.0mils(120µm).Inordertoachievesufficientopacity,it
maybecomenecessarytoapplyorganicpigmentedtopcoatsatahigherfilmthickness.Pleasenotethatnon-pigmented
topcoats,suchasclearcoatsortransparenteffectsarenotsuitedforaTIGERShield®application.

page 3 of 5 Version 02-14Data Sheet 69-1002

Series 69 - DRYZINC® Zinc-Rich Primer (69/90500)

TI

G E R D ry la c U .S .A In c.

S w en so n A ve nu e | S t C ha rle s, IL

T

F of fic e.

us tig er -c oa tin gs .u s | w w w .ti ge r-co at in gs

Test Results

Resultsarecheckedona1/8inch(3mm)gaugezincphosphated,steelpanel,two-coatTIGERShield®system(TIGERDryzinc®
69/90500andasmoothglossyfinishtopcoat)withatotalfilmthicknessofmaximum6.4mils(160µm).Cureconditionsaccording
tothecurecurves.

Test results Test method Dryzinc® 69/90500 + TIGER Drylac® Series 38

Film thickness 5.0-7.0mils
(120-180µm)

Cross cut tape test 2 mm

ASTM D3359 5B

Humidity resistance 1,000 hours

ASTMD2247 Maximumundercutting1/32inch(1mm).
Noblistering.

Salt spray resistance 3,000 hours

ASTMB117 Maximumundercutting1/32inch(1mm).
Noblistering.

Porosity of paint films ASTM D3258 Non-porous.

Cleaning recommendations: Refer to the latest edition of TIGER “Cleaning Recommendations” information sheet, Version 00-1005.

Test results Test method Dryzinc® 69/90500 + TIGER Drylac® Series 38

Tested corrosion resistance ENISO12944 C5-Ilong
IKStestreportPB300/64/00*

Suitable for application in pre-stressed and highly fastened bolted connections

DIN18800Part1*** Unrestricteduseforboltedconnections
ISLtestreportPB10/00**

Test results Test method Dryzinc® 69/90500 + TIGER Drylac® Series 38

Tested corrosion resistance ENISO12944 C5-Ilong
IKStestreportPB300/64/00*

Suitable for application in pre-stressed and highly fastened bolted connections

DIN18800Part1*** Unrestricteduseforboltedconnections
ISLtestreportPB10/00**
*InstituteforCorrosionProtection,Dresden,Germany
**InstituteforSteelConstruction,Leipzig,Germany
***DIN=GermanIndustrialStandard
IfthemetalpreparationandpretreatmentarefollowedaccordingtotheinstructionsassetforthinthisProductDataSheet,the
TIGERShield®systemwillyieldprotectionagainstcorrosionthatmeetstherequirementsofacorrosionclassC5-Ilongaccording
toENISO12944partVI.
TIGER Shield®(Pretreatmentwithzincphosphating)
Resultsarecheckedona1/8inch(3mm)zincphosphatedsteelpanel,two-coated-structure(TIGERDryzinc®69/90500anda
smoothglossyfinishtopcoat)withageneralmaximumfilmthicknessof6.4mils(160µm).Cureaccordingtotherelevantcuring

parameters.

TIGER Shield® (Metalpreparationwithblasting)
Resultsarecheckedona1/8inch(3mm)gaugeblastedsteelpanel,two-coatTIGERShield®system(TIGERDryzinc®69/90500
andasmoothglossyfinishtopcoat)withatotalmaximumfilmthicknessof5.0-7.0mils(120-180µm).Cureconditionsareaccording
tothecurecurves.

page 4 of 5 Version 02-14Data Sheet 69-1002

Series 69 - DRYZINC® Zinc-Rich Primer (69/90500)

TI

G E R D ry la c U .S .A In c.

S w en so n A ve nu e | S t C ha rle s, IL

T

F of fic e.

us tig er -c oa tin gs .u s | w w w .ti ge r-co at in gs

Chemical Resistance

Therequiredchemicalresistanceofapowdercoatingdepends,amongotherthings,onitsformulation.Chemicalresistance
requirementsmustbeconsideredaccordingtoprocessingconditionsandfinaluseofthefinishedproduct.Thisisbest
establishedduringtheproductspecificationprocess.Agreementbetweenallpartiesinvolvedmustbereachedaboutthe
requirementsforsuchchemicalresistanceaswellasthetestmethod,whichmaybeperformedinaccordancewithPCItest
method#8“SolventCureTest”.Furthermore,thetestdurationandconcentrationofthetestmedianeedtobeagreedupon.

Certified according to

ISO 9001 | 14001

page 5 of 5 Version 02-14Data Sheet 69-1002

AspartofTIGERDrylac®productinformationprogram,ProductDataSheetsareupdatedperiodically.Itisrecommended
toalwayscheckforthelatesteditionsonTIGER’swebsite.TIGER’sverbalandwrittenrecommendationsfortheuseof
itsproductsarebaseduponexperienceandinaccordancewithcurrenttechnologicalstandards.Thesearegiveninorder
tosupportthebuyeroruser.Theyarenon-committalanddonotcreateanyadditionalcommitmentstothepurchase
agreement.TheydonotreleasethebuyerfromverifyingthesuitabilityofTIGERproductsfortheintendedapplication.This
ProductDataSheetsupersedesallpreviousProductDataSheetversionsandnotespublishedinrelationtothisproduct.

Series 69 - DRYZINC® Zinc-Rich Primer (69/90500)

TI

G E R D ry la c U .S .A In c.

S w en so n A ve nu e | S t C ha rle s, IL

T

F of fic e.

us tig er -c oa tin gs .u s | w w w .ti ge r-co at in gs .u s

TIGER Drylac U.S.A., Inc.

3855SwensonAvenue
StCharles,IL60174,USA
T8002438148
F8779268148
Eoffice.us@tiger-coatings.us
Wwww.tiger-coatings.us

Data Sheet 38-1000 Version 02-14TI G

E R

D ry la c

U .S

.A

In c.

S w en so n

A ve nu e

| S t C ha rle s, IL

T

F of fic e.

us tig er

-c oa tin gs

.u s

| w w w .ti ge r-co at in gs

.u s SERIES 38 – SUPER DURABLE

Polyester TGIC super durable powder coating compliant to AAMA 2604 with excellent weather resistance properties for high performance architectural exterior applications.

Typical Applications

• Metal façades.

• Steel constructions.

• Stadium seating and railings.

• Residential windows and doors.

• Patio furniture and garden equipment.

• Railings.

• Playground equipment.

• Agriculture equipment.

• External ship components, communication towers, doors and railings.

• Military camouflage.

Standard Packaging 44 lb (20 kg) box.

5 lb (2.5 kg) minipack.

Specific Gravity

(ASTM D792)

approximately 1.2-1.8 g/cm3 depending on pigmentation.

Theoretical Coverage at 1.5 specific gravity and

2.5 mils (60 µm) film thickness:

30.2 ft2/lb (9.8 m2/kg).

Refer also to the latest edition of “Theoretic Powder Coating Coverage Chart”.

Version 00-1001 (imperial).

Version 00-1000 (metric).

Storage Stability 6 months at no more than 77 °F (25 °C).

Features

• Excellent weather resistance.

• Excellent UV-light resistance.

• AAMA 2604-10* compliant.

• 5 years South Florida exposure.

• Very smooth flow.

• Good storage stability.

• Good yellowing stability.

* AAMA 2604-10 compliance dependent upon the color and|or effect.

Finish and Color

• Smooth flow glossy, approximately 80-95+*.

• Smooth flow semi gloss, approximately 60±5*.

• Smooth flow matte, approximately 20±5*.

* Gloss level according to ASTM 523 at 60° angle.

Available as stock product in smooth glossy, semi gloss and matte in 70 colors. It can be custom matched in limited colors (minimum order quantity and color limitation applies).

Product Data Sheet

E R

D ry la c

U .S

.A

In c.

S w en so n

A ve nu e

| S t C ha rle s, IL

T

F of fic e.

us tig er

-c oa tin gs

.u s

| w w w .ti ge r-co at in gs

.u s

The following table reflects the common methods of pretreatment with regards to various substrates and applications. In selecting the proper type of pretreatment the suitability of the type of powder coating for a desired application according to the guidelines on page one of this Product Data Sheet should be observed.

Pretreatment (alternatives)

Processing

Corona

Tribo*

Cure Parameters (substrate temperature)

TIGER Drylac® Series 38 Cure Parameters | Smooth Glossy

Substrate temperature versus curing time

To achieve a full cure and the desired mechanical properties and weatherability the time/temperature combination must fall within the cure window.

Interior.

Exterior.

Architectural.

Steel construction.

1) According to ASTM B 449.

2) According to GSB quality and test regulations.

3) Only for zinc coated parts >1.8 mils (>45 μm).

4) For a two-coat process/TIGER Shield®.

I

E

A

S

* For Tribo/Airstatic powder coatings please confirm before ordering. Suitability of metallic effects for Tribo processing must be verified prior to application. Please refer to the latest edition of the relevant Information Sheets.

Since not all powder coatings are suitable for recycling/reclaim, please verify before ordering.

Weather Resistance Florida exposure at 45° angle

Facing South - RAL 8014

Remaining gloss versus months

The remaining gloss values that can be expected may vary depending on the original gloss level and color. A reasonable degree of gloss loss and color variation owing to long term UV exposure should be expected.

Series 38 - Super Durable

E R

D ry la c

U .S

.A

In c.

S w en so n

A ve nu e

| S t C ha rle s, IL

T

F of fic e.

us tig er

-c oa tin gs

.u s

| w w w .ti ge r-co at in gs

.u s

5 years Florida exposure

Color change ASTM D2244 ≤∆ε 5.0 (Hunter).

Gloss retention ASTM D523 >80%

Top coating with a clear exterior grade powder coating over an interior grade powder coating does not result into a weather resistant coating system.

Post-bending properties of any part must be verified prior to application. Minor cracks in the coated surface may lead to corrosion.

Joint sealants and any other auxiliary products, such as glazing aids, gliding waxes, drilling and cutting lubricants, which come in contact with the coated surface must be pH-neutral and free of substances that may damage the finish. Therefore, a suitability test at the applicator’s end, prior to coating, is highly recommended.

In general, colors in the red, orange and yellow range may require an increased film thickness to achieve full hiding.

Any post-mechanical processing of already coated parts, such as sawing, drilling, milling, cutting and bending will result in damage of the coated surface and will subsequently weaken the corrosion protection.

Please read and understand the Material Safety Data Sheet (MSDS) before use.

Please Note

Test Results Results are checked on 1/64 inch (0.7 mm) thick yellow chromated aluminum test panel. Cure conditions are according to the cure curves. When used as a two-coat system, the increase in film thickness will result in a decrease of mechanical properties.

Test results Test method Series 38 Smooth Glossy

Film thickness ISO 2360 2.5-3.5 mils (60-80 µm)

Gloss - 60° ASTM D523 80-95+

Cross hatch adhesion test ASTM D3359 Method B 5B

Mandrel bending test ASTM D522 1/8 inches (3 mm).

Impact test ASTM D2794 Up to 80 in/lb.

Cracking at the perimeter of the concave area but no cracking pick off.

Pencil hardness ASTM D3363 2H minimum.

Weathering EN 20105 - A02 ≥4

Light fastness EC ISO 105 - B02 ≥Grade7

Humidity resistance 3,000 hours

ASTM D2247 Maximum undercutting 1/32 inches (1 mm).

Acid salt spray resistance 2,000 hours

ASTM G85

Annex A5 Maximum undercutting 1/32 inches (1 mm).

Cleaning recommendations: Refer to the latest edition of TIGER “Cleaning Recommendations” information sheet, Version 00-1005.

E R

D ry la c

U .S

.A

In c.

S w en so n

A ve nu e

| S t C ha rle s, IL

T

F of fic e.

us tig er

-c oa tin gs

.u s

| w w w .ti ge r-co at in gs

.u s Special Applications

Objects directly exposed to salt/fog conditions in a marine environment or need heavy corrosion protection must be coated with TIGER Shield® system. Refer to the latest editions of TIGER Drylac® Product Data Sheets.

TIGER Drylac U.S.A., Inc.

3855 Swenson Avenue St Charles, IL 60174, USA T 800 243 8148 F 877 926 8148 E office.us@tiger-coatings.us W www.tiger-coatings.us

Certified according to

ISO 9001 | 14001

As part of TIGER Drylac® product information program, Product Data Sheets are updated periodically. It is recommended to always check for the latest editions on TIGER’s website. TIGER’s verbal and written recommendations for the use of its products are based upon experience and in accordance with current technological standards. These are given in order to support the buyer or user. They are non-committal and do not create any additional commitments to the purchase agreement. They do not release the buyer from verifying the suitability of TIGER products for the intended application. This Product Data Sheet supersedes all previous Product Data Sheet versions and notes published in relation to this product.

Chemical Resistance

The required chemical resistance of a powder coating depends, among other things, on its formulation. Chemical resistance requirements must be considered according to processing conditions and final use of the finished product. This is best established during the product specification process. Agreement between all parties involved must be reached about the requirements for such chemical resistance as well as the test method, which may be performed in accordance with PCI test method #8 “Solvent Cure Test”. Furthermore, the test duration and concentration of the test media need to be agreed upon.

DOUBLE GATE

HEAVY DUTY

BLOCK HINGES

Double Gate & Hinges Perforated Metal Sheet

Product Data

Perforated sheet to be same color as fencing.

McNICHOLS® Quality Round Hole Perforated Visit us online at http://www.mcnichols.com

Item Specifications

Item Number BARCD000000000005090

Product Line Perforated

Product Type Round Hole

Weight 0.74 #/SF

Margins Parallel to Length Min Safe Both Sides

Margins Parallel to Width Min Safe Both Ends

End Pattern Unfinished

Width 48.0000"

Length (Span for Grating) 120.0000"

Major Material Aluminum

Minor Material Type 3003-H14

Gauge (Thickness) .125

Hole Size 1.0000"

Hole Centers 1.2500"

Hole Pattern Staggered

Surface Finish Mill

SKU Type Sheet

Trade Name McNICHOLS_R

Class Round Hole

% Open Area 58

Straight Rows Parallel To Length

Holeserve Item Number 1701921241

Item Accessories

U Edging U-shaped products designed to be cut to size and fit over a rough edge of a sheet good to provide protection and appearance value.

Item Applications

Architectural/Decorative Applications where the appearance of the finished item is as important as the function of the item.

Container/Enclosure Products used as components of a container. The container may be to keep objects in or as a secrity device to keep people or things out.

McNICHOLS® Quality Round Hole Perforated Visit us online at http://www.mcnichols.com

Filter/Screen Material used to reduce the flow of a liquid or gas, to limit the size of a particulate or to reduce the amount of light allowed to pass.

Fixture/Furniture Material used as a component in a fixture or furniture.

Grille/Guard Material used in some way to restrict access to an area.

Panel/Partition Material used as the means to stop the passage of something from one place to another.

Part/Equipment Products used as parts on equipment or machinery.

Railings Products used to form a physical barrier around an area or platform, typically a handrail.

Product URL http://www.mcnichols.com/product/1701921241?navCode=cc:round

Product Photo

File details come from the government source that posted it. Updated .