3-SSLC 3rd Floor Construction Drawings 2.27.26 .pdf
PDF 15 MB Posted
- Attached to
- 2026 City Hall Third Floor Remodel
- Solicitation number
- PN 2026-10
- Issued by
- Salt Lake County, Salt Lake City, Utah
About this file
Construction Documents Summary: South Salt Lake City Hall 3rd Floor Renovation
These are comprehensive construction documents for the interior remodeling of the third floor of South Salt Lake City Hall, located at 220 E Morris Avenue, South Salt Lake, Utah. The project encompasses approximately 9,200 square feet across three departmental areas: IT, Engineering, and Outreach, with a total occupant load of 160 persons. The scope includes selective demolition of existing finishes and infrastructure, installation of new interior partitions with gypsum board construction, suspended acoustic ceiling systems, flooring materials (carpet tile and laminate vinyl tile), cabinetry and millwork, door frames and hardware, plumbing fixtures, HVAC systems with two 3-ton heat pump units and VAV boxes, electrical systems including three panelboards, lighting control systems with occupancy sensors and daylighting controls, fire alarm integration, and a specialized clean agent fire suppression system for the server room. The project must comply with the 2021 International Building Code, 2021 International Mechanical Code, 2020 National Electrical Code, and ADA accessibility standards. An optional pre-bid meeting is scheduled for March 18, 2026, at 10:00 AM on site, with bid submissions due by 3:00 PM on March 25, 2026, and plans available through Utah Public Procurement Place (U3P) beginning March 5, 2026.
The project requires a 5% bid security, with all bids submitted as complete packages to Ariel Andrus, City Recorder, either in print or as a single combined PDF to aandrus@sslc.gov. The construction documents include detailed specifications for materials including copper plumbing with lead-free solder, PVC DWV piping, Type K copper tubing for domestic water, sheet metal ductwork with insulation, electrical conduit systems, and gypsum board with fire-rated assemblies where required. Contractor responsibilities include field verification of dimensions and existing conditions, coordination of all trades, seismic bracing for equipment and ceilings per ICC requirements, firestopping and penetration sealing, provision of all temporary utilities and protection measures, and commissioning of the fire suppression system with room integrity testing. The City of South Salt Lake reserves the right to reject any or all bids and to modify the scope of work as deemed in the city's best interest.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
186 N. 100 E. SUITE A
KAYSVILLE, UT 84037
(801) 882-7208
WWW.ONYXDESIGNCOLLECTIVE.COM
AT
T S
AT
UE FO
H
L
IC
E
N
SED ARCH
IT
E
C T
No. 8246979-0301
KINLEY C. PUZEY
CITY OF SOUTH SALT LAKE
CITY HALL 3RD FLOOR RENOVATION
02-20-2026
CONSTRUCTION DOCUMENTS
220 E MORRIS AVE., SOUTH SALT LAKE, UT 84115
02-20-2026
NORTH
A101
SIM
A101
SIM
A101
SIM
A101
SIM
DRAWING TAGS
CEILING TYPE
CEILING TAG
SHEET SYMBOLS
WINDOW TAG
REVISION TAG
REVISION NUMBER
FLOOR TRANSITION MARKER
TRANSITION
SYMBOL
CEILING HEIGHT
WINDOW MARKER
ELEVATION MARKER
AMATCH LINE
SECOND LEVEL
116'-0"
BUILDING SECTION
WALL SECTION
NUMBER
DIRECTION
OF VIEW
SHEET WHERE DRAWN
WALL SECTION
WALL
SECTION
NUMBER
PROJECT NORTH
GRID
IDENTIFICATION
LAYOUT GRID LINES
SHEET
WHERE
DRAWN
DIRECTION OF
VIEW
LEVEL LINE
ROOM NAME AND NUMBER
DETAIL REFERENCE
SECTION DETAIL REFERENCE
EXTERIOR ELEVATION
INTERIOR ELEVATION
SEE PARTITION
SYMBOL
DESCRIPTION ON
SHEET
A9.2
PARTITION TYPE MARK
ELEVATION
NUMBER AND
DIRECTION
SHEET WHERE
DRAWN
SHEET
WHERE
DRAWN
ELEVATION
NUMBER
AND
DIRECTION
SHEET WHERE
DRAWN,
HYPHEN
INDICATES
DETAIL
ON SAME
SHEET.
DETAIL
NUMBER
SHEET WHERE
DRAWN
ELEVATION
NUMBER AND
DIRECTION
AX.X
AX.X
X
XX
A
X'- X"X
X XGLAZING MARKER
DRAWING TITLE
SCALE
ROOM NAME
PROJECT
LOCATION
I-80I-80
I-
I-
S T
A T
E S
T
S T
A T
E S
T
2100 S FWY.
Rev # Date Description
Job #
Drawn
Date
Owner #
Checked
186 N. 100 E. SUITE A
KAYSVILLE, UT 84037
(801) 882-7208 www.onyxdesigncollective.com
NOTE: THIS DRAWING IS INTENDED FOR A
24"X36" SHEET. IF IT HAS BEEN PRINTED ON
ANYTHING ELSE IT IS A REDUCED COPY.
PLEASE SCALE DRAWING ACCORDINGLY.
AT
T S
AT
UE FO
H
L
IC
E
N
SED ARCH
IT
E
C T
No. 8246979-0301
KINLEY C. PUZEY
/2
/2
:0
:2
P
M
G1.1
GENERAL
INFORMATION
CITY OF SOUTH SALT
LAKE
C
IT
Y H
A L
L
R D
F L O
O R
R E
N O
V A
T
IO
N
CheckerAuthor 02-20-2026
25.004
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
E M
O R
R
IS
A V
E S
O U
T H
S A
L T
L A
K E
U
T
02-20-2026
A.F.F. ABOVE FINISH FLOOR
A.S. AIR SPACE
ASPH. ASPHALT
& AND
@ AT
ALUM. ALUMINUM
ARCH. ARCHITECTURAL
BLDG. BUILDING
BTM. BOTTOM
BD. BOARD
C.G. CORNER GUARD
CTJ. CONTRACTION JOINT
CL CENTER LINE
CONC. CONCRETE
C.M.U. CONCRETE MASONRY UNIT
CO COMPANY
CORR. CORRIDOR
COL. COLUMN
COMP. COMPUTER
CONT. CONTINUOUS
CLG. CEILING
C.S. CLOSURE STRIP
CLS CLOSET
C.T. CERAMIC TILE
CLR CLEAR
C.O. CLEAN OUT
C.O.T.G. CLEAN OUT TO GRADE
C.I. CAST IRON
DEPT DEPARTMENT
DIA. DIAMETER
D.F. DRINKING FOUNTAIN
DN DOWN
DISP. DISPENSER
DIM. DIMENSION
DT./DTL./DET. DETAIL
DWG./DRWNG. DRAWING
DRN. DRAIN
EA. EACH
ELEV./EL. ELEVATION
EXIST./(E) EXISTING
ELECT. ELECTRICAL
EQUIP. EQUIPMENT
E.E.S. EMERGENCY EYEWASH AND SHOWER
E.J. EXPANSION JOINT
EIF EXTERIOR INSULATION SYSTEM
EVAP EVAPORATIVE
EXP. EXPANSION
F.G. FINISH GRADE
ABBREVIATIONS
F.D. FLOOR DRAIN
FDN./FNDTN. FOUNDATION
F.E. FIRE EXTINGUISHER
FTG. FOOTING
FLR. FLOOR
F.A. FIRE ALARM
FIN. FINISHED
F.H. FIRE HYDRANT
F.V. FIELD VERIFY
G.W.B. GYPSUM WALLBOARD
GYP. GYPSUM
GA. GAUGE
GALV. GALVANIZED
G.I. GALVANIZED IRON
H.M. HOLLOW METAL
H.C. HANDICAP
H.P. HIGH POINT
HT. HEIGHT
HORIZ. HORIZONTAL
H.W. HARDWOOD
INSUL. INSULATION
I.D. INSIDE DIAMETER
K.O. KNOCK OUT
KW KILOWATTS
LBS POUNDS
MECH. MECHANICAL
MEZZ MEZZANINE
MFR/MNFR MANUFACTURER
MGR MANAGER
M.T. MEN'S TOILET
MTL. METAL
MAX. MAXIMUM
MIN. MINIMUM
M.O. MASONRY OPENING
M.H. MANHOLE
MACH. MACHINERY
M.C.C. MOTOR CONTROL CENTER
MISC. MISCELLANEOUS
N. NORTH
NO. NUMBER
N.I.C. NOT IN CONTRACT
NOM. NOMINAL
N.T.S. NOT TO SCALE
OPG. OPENING
O.C. ON CENTER
O.H. OVERHEAD
O.D. OUTSIDE DIAMETER
PERM. PERIMETER
PL. PLATE
PNTH PENTHOUSE
PTN. PARTITION
P.W. PLYWOOD
P.O.C. POINT OF CONNECTION
P.C. PORTLAND CEMENT
PNL. PANEL
P.F.H. PERIMETER FELT JOINT
Q.T. QUARRY TILE
R.D. ROOF DRAIN
R.O. ROUGH OPENING
RM. ROOM
REINF. REINFORCED
REC. RECESSED
R.W. RETAINING WALL
S. SCUPPER
S.B.U. STRUCTURAL BRICK UNIT
SF SQUARE FOOT
STOR. STORAGE
SIM. SIMILAR
SUSP. SUSPENDED
SYS. SYSTEM
SPECS. SPECIFICATIONS
STRG. STORAGE
STRUCT. STRUCTURAL
ST. STEEL
SCH. SCHEDULE
S.S. STAINLESS STEEL
S.W. SOFT WOOD
SERV. SERVICE
TYP. TYPICAL
TRANS. TRANSFORMER
T & B TOP AND BOTTOM
T.O. TOP OF
T. TOILET
U.O.N./U.N.O UNLESS OTHERWISE NOTED
UR. URINAL
VAR. VARIES
VEST. VESTIBULE
VERT. VERTICAL
W.C. WATER CLOSET
W.H. WATER HEATER
W.T. WOMEN'S TOILET
WD. WOOD
WSCT. WAINSCOT
W/ WITH
W.W.F. WELDED WIRE FABRIC
DESIGN DATA DRAWING INDEX
VICINITY MAP
NOTES TO BIDDERS
PROJECT TEAMSYMBOL LEGEND
1. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY. CONTRACTOR TO SUBMIT SHOP DRAWING AND MATERIAL AND FINISH SAMPLES TO THE ARCHITECT FOR REVIEW.
2. AS PART OF THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE WORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS, THE CONTRACTOR SHALL ENDEAVOR TO IDENTIFY AND NOTIFY THE ARCHITECT OF ANY CONFLICTS BETWEEN THE WORK OF DIFFERENT PARTIES AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING THE WORK. ALL DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE ARCHITECT.
3. THE ARCHITECTURAL DRAWINGS ESTABLISH THE FINISHED APPEARANCE AND LOCATION OF EXPOSED ELEMENTS OF THE WORK OF ALL THE TRADES, INCLUDING THAT WORK WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES. QUANTITIES ARE TO BE PROVIDED AS SHOWN ON DRAWINGS OF OTHER DISCIPLINES BUT LOCATIONS SHOWN ON OTHER DRAWINGS ARE SCHEMATIC, UNLESS OTHERWISE NOTED ON THE ARCHITECTURAL DRAWINGS. THE ARCHITECTURAL DRAWINGS TAKE PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL PARTS OF THE WORK.
4. CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS OF THE SITE PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT OF ANY
DISCREPANCIES AND A CLARIFICATION WILL BE ISSUED.
5. VERIFY THAT ALL WORK CONFORM WITH THE GOVERNING BUILDING CODES LISTED ON THIS SHEET AS WELL AS THE REQUIREMENTS AND REGULATIONS
OF THE LOCAL MUNICIPALITY.
6. CONTRACTOR IS RESPONSIBLE FOR CORRECTION OF WORK AT HIS OWN EXPENSE FOR WORK COMPLETED THAT WAS NOT DONE IN COMPLIANCE WITH
THESE DOCUMENTS AND BUILDING CODE.
7. VERIFY THE LOCATION OF ALL PLUMBING RUNS, MECHANICAL DUCTS, AND VENT OPENINGS WITH MECHANICAL CONTRACTOR PRIOR TO POURING THE SLAB. ACCESS PANELS TO BE PROVIDED AND INSTALLED BY CONTRACTOR AS REQUIRED. LOCATION TO BE APPROVED BY ARCHITECT.
8. PROVIDE NECESSARY STIFFENERS, BLOCKING, BRACING, HANGERS, ETC. FOR ALL CABINETRY, EQUIPMENT, FURNISHINGS, TOWEL BARS, OR OTHER
ITEMS.
9. FLASHING AND COUNTER FLASHING IS TO BE PROVIDED AT ALL NECESSARY LOCATIONS AS PER BUILDING CODE. THESE LOCATIONS INCLUDE, BUT ARE NOT LIMITED TO, THE CONNECTION OF A ROOF WITH A VERTICAL SURFACE, EXTERIOR OPENINGS, IN-PLANE MATERIAL CHANGES, ROOF VALLEYS AND
RIDGES, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SURFACES, ETC.
10. ALL NEW CONSTRUCTION TO CONFORM TO THE 2021 INTERNATIONAL BUILDING CODE & ALL APPLICABLE LOCAL CODES & REGULATIONS.
11. THE HVAC SYSTEM SHALL HEAT & COOL UNIFORMLY THROUGHOUT OFFICE AREA IN COMPLIANCE WITH THE 2021 INTERNATIONAL MECHANICAL CODE
UNDER THE GUIDELINES OF ASHRAE 90A.
12. THE CONSTRUCTION & INSTALLATION OF ALL DUCTWORK SHALL COMPLY WITH CHAPTER 6 OF THE 2021 INTERNATIONAL MECHANICAL CODE.
13. FIRE EXTINGUISHERS ARE TO BE PROVIDED IN ACCORDANCE WITH NFPA 101, SECTION 38.3.5 AND PLACED AS PER NFPA 10.
14. ALL FINISHES TO COMPLY WITH 2021 LIFE SAFETY CODE, SECTION 10.2. CARPET TO COMPLY W/ ASTM D 2859, OR HAVE 'CLASS II' RATING.
15. INTERIOR SIGNAGE SHALL COMPLY WITH THE 2009 ADA STANDARDS FOR ACCESSIBLE DESIGN.
16. CONTRACTOR AND OWNER ARE RESPONSIBLE TO GET REQUIRED PERMITS FOR CONSTRUCTION.
GENERAL NOTES
1. THIS SHEET CONTAINS A LIST OF DRAWINGS WHICH COMPRISE A FULL
SET OF DRAWINGS FOR THIS PROJECT. ANY CONTRACTOR,
SUBCONTRACTOR, VENDOR OR ANY OTHER PERSON PARTICIPATING
IN OR BIDDING ON THIS PROJECT SHALL BE RESPONSIBLE FOR THE
INFORMATION CONTAINED IN ANY AND ALL SHEETS OF DRAWINGS. IF
ANY PERSON, PARTY OR ENTITY ELECTS TO SUBMIT BIDS FOR ANY
PORTION, OR ALL, OF THIS PROJECT, THAT PERSON, PARTY OR
ENTITY SHALL BE RESPONSIBLE FOR ANY AND ALL INFORMATION
CONTAINED IN THESE DRAWINGS AND SPECIFICATIONS, INCLUDING,
BUT NOT LIMITED TO, ANY SUBSEQUENT ADDENDUM OR
CLARIFICATIONS THAT MAY BE ISSUED.
2. THESE DOCUMENTS SHOW THE DESIGN INTENT. IT IS THE
CONTRACTORS RESPONSIBILITY TO PROVIDE EVERYTHING SHOWN
ON THE DRAWINGS REGARDLESS OF WHERE IT IS SHOWN ON THE
DRAWINGS AS WELL AS EVERYTHING REQUIRED FOR THE BUILDING
TO BE BUILT TO CODE REGARDLESS OF IF THEY ARE EXPLICITLY
DETAILED IN THE DRAWINGS OR NOT.
3. EVERYTHING CALLED FOR IN THESE DOCUMENTS SHALL BE "NEW"
AND PROVIDED BY THE CONTRACTOR, SUBCONTRACTOR, VENDOR
OR ANY OTHER PERSON PARTICIPATING IN OR BIDDING ON THIS
PROJECT UNLESS NOTED OTHERWISE AS EXISTING (EXIST), NOT IN
CONTRACT (NIC) OR FOR REFERENCE ONLY. FURNISHINGS SHOWN
DASHED SHALL BE FOR REFERENCE ONLY.
GENERAL
G1.0 COVER SHEET
G1.1 GENERAL INFORMATION
G1.2 PROJECT SPECS
G1.3 PROJECT SPECS / NOTES
G1.4 ADA
G1.5 EGRESS PLAN
DEMOLITION
D1.1 LEVEL 3 IT DEPT. DEMOLITION PLAN
D1.2 LEVEL 3 ENGINEERING DEMOLITION PLAN
D1.3 LEVEL 3 OUTREACH DEMOLITION PLAN
D1.4 LEVEL 3 IT DEPT. DEMO REFLECTED CEILING PLAN
D1.5 LEVEL 3 ENGINEERING DEMO REFLECTED CEILING PLAN
D1.6 LEVEL 3 OUTREACH DEMO REFLECTED CEILING PLAN
ARCHITECTURAL
A1.7 LEVEL 3 OVERALL FINISH PLAN
A1.0 LEVEL 3 OVERALL FLOOR PLAN
A1.1 LEVEL 3 IT DEPT. FLOOR PLAN
A1.2 LEVEL 3 ENGINEERING FLOOR PLAN
A1.3 LEVEL 3 OUTREACH FLOOR PLAN
A1.4 LEVEL 3 IT DEPT. REFLECTED CEILING PLAN
A1.5 LEVEL 3 ENGINEERING REFLECTED CEILING PLAN
A1.6 LEVEL 3 OUTREACH REFLECTED CEILING PLAN
A4.0 INTERIOR ELEVATIONS
A5.0 DETAILS
A5.1 DETAILS
A6.0 DOOR AND WINDOWS
MECHANICAL
M001 TITLE SHEET (LEGEND AND ABBREVIATIONS)
M100 OVERALL MECHANICAL PLAN
M101 LARGE SCALE IT DEPT. MECHANICAL DEMOLITION PLAN
M102 LARGE SCALE ENGINEERING MECHANICAL DEMOLITION
PLAN
M103 LARGE SCALE OUTREACH MECHANICAL DEMOLITION PLAN
M201 LARGE SCALE IT DEPT. MECHANICAL PLAN
M202 LARGE SCALE ENGINEERING. MECHANICAL PLAN
M203 LARGE SCALE OUTREACH MECHANICAL PLAN
M701 MECHANICAL DETAILS & SCHEDULES
ELECTRICAL
EG001 GENERAL NOTES AND SYMBOLS LISTS
EG002 SYMBOLS LISTS
EG003 ELECTRICAL SPECS
EG501 ELECTRICAL DETAILS
EG502 ELECTRICAL DETAILS
EG503 ELECTRICAL DETAILS
EG504 ELECTRICAL DETAILS
ED101 LEVEL 3 ELECTRICAL DEMOLITION LIGHTING PLAN
ED102 LEVEL 3 ELECTRICAL DEMOLITION PLAN
ED701 ONE-LINE DIAGRAM-POWER
EL101 LEVEL 3 LIGHTING PLAN
EL501 LIGHTING DETAILS
EL502 LIGHTING CONTROL NARRATIVE & DETAILS
EL503 LIGHTING WIRING DIAGRAMS
EL504 LIGHTING WIRING DIAGRAMS
EL601 LIGHT FIXTURE SCHEDULE
EP101 LEVEL 3 ELECTRICAL FLOOR PLAN
EP701 ONE-LINE DIAGRAM-POWER
EP801 ELECTRICAL SCHEDULES
EY101 LEVEL 3 SYSTEMS PLAN
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING CODES:
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL PLUMBING CODE (IPC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL FIRE CODE (IFC)
2020 NATIONAL ELECTRICAL CODE (NEC)
ASHRAE 90-1-2013 AND SUBSEQUENT ADDENDA
AMERICANS WITH DISABILITIES ACT (ADA)
ANSI ICC A117.1-2009
2021 INTERNATIONAL EXISTING BUILDING CODE
TENANT INFORMATION
TENANT USE GROUP B - BUSINESS
GROSS BUILDING AREA 61,200 (4 STORIES)
REMODELED AREA APPROX. 9,200 SQ. FT.
DESIGN OCC. 160
FIRE SPRINKLERED YES
BUILDING TYPE VB
PLUMBING
WATER CLOSETS 1/25 EXISTING
LAVATORIES 1/40 EXISTING
DRINKING FOUNTAIN EXISTING
N
• FIRE SPRINKLERS
• SERVER ROOM: CLEAN AGENT (CHEMICAL) FIRE
SUPPRESSION SYSTEM
DEFERRED SUBMITTALS
ARCHITECT
OWNER
GENERAL CONTRACTOR
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
ONYX DESIGN COLLECTIVE
KINLEY C. PUZEY, AIA
KINLEY@ONYXDEISNGCOLLECTIVE.COM
801.699.7801
TBD
ENVISION ENGINEERING
TREVOR SPENCER
TSPENSER@ENVISIONENG.COM
801.534.1130
JTB HVAC AND PLIMBING ENGINEERING
JEFF BROWN
JEFF.BROWN@JTBENGINEERING.NET
801.849.8590
SOUTH SALT LAKE CITY
STEVE NIEDERHAUSER
SNIEDERHAUSER@SSLC.GOV
801.483.6016
1. DEDICATED FIRE SUPPRESSION NOTES AND SCOPE
A. INCLUDE A DEDICATED “SERVER ROOM FIRE SUPPRESSION” THAT COVERS:
B. TYPE OF SYSTEM (E.G., “CLEAN AGENT FIRE SUPPRESSION SYSTEM, FIKE FK-5-1-12 OR EQUAL”)
C. CLEAN AGENT SYSTEM
D. LISTING REQUIREMENTS (UL/FM LISTED)
E. REQUIRED STANDARDS (NFPA 2001 FOR CLEAN AGENT SYSTEMS)
F. SYSTEM TO BE INSTALLED BY A LICENSED FIRE PROTECTION CONTRACTOR
2. SERVER ROOM ENVELOPE SPECIFICATIONS
SEALED ROOM ENCLOSURE: ALL PENETRATIONS (CABLE TRAYS, DUCTS, CONDUITS) MUST BE SEALED TO HOLD AGENT CONCENTRATION (TYPICALLY 10-
MINUTE HOLD).
A. MINIMUM ROOM HEIGHT, DIMENSIONS FOR CALCULATION
B. FIRE RATING: IF REQUIRED, IDENTIFY ASSEMBLY RATINGS FOR WALLS, FLOOR/CEILING, AND DOOR.
C. SEAL TO BE APPROVED BY CITY IT DEPT. SEAL NEEDS TO BE REMOVABLE FOR FUTURE WIRING.
3. MECHANICAL COORDINATION
HVAC INTERLOCK: SYSTEM ACTIVATION SHUTS DOWN HVAC TO PREVENT DISCHARGE LOSS.
PRESSURE RELIEF VENT: REQUIRED TO AVOID OVERPRESSURIZATION AND MEET NFPA 2001 REQUIREMENTS.
4. DETECTION & CONTROL
A. SPOT SMOKE DETECTORS TIED INTO THE CLEAN AGENT SYSTEM (DUAL OR CROSS-ZONE DETECTION)
B. MANUAL PULL STATIONS AND ABORT SWITCHES
C. AUTOMATIC CONTROL PANEL LOCATION (WITHIN 6 FEET OF THE ROOM ENTRANCE)
5. ELECTRICAL COORDINATION
A. DEDICATED POWER SOURCE FOR THE SYSTEM (UNINTERRUPTED)
B. CONTROL WIRING COORDINATION NOTES WITH FIRE ALARM PANEL
C. SYSTEM MONITORING: CONNECT TO BUILDING FIRE ALARM FOR SUPERVISORY FUNCTIONS
6. DOOR HARDWARE & SIGNAGE
A. DOOR HARDWARE THAT PREVENTS UNWANTED ENTRY BUT ALLOWS EGRESS AFTER DISCHARGE
B. “DO NOT ENTER AFTER DISCHARGE” AND “CLEAN AGENT PROTECTED AREA” SIGNAGE
C. DOOR HARDWARE FOR ACCESS CONTROLS NEEDS COORDINATED WITH CITY IT DEPT. AND CITY AMAG VENDOR
7. ROOM INTEGRITY TEST
A. INCLUDE A NOTE REQUIRING THE FIRE PROTECTION CONTRACTOR TO PERFORM A DOOR FAN TEST (FORMERLY KNOWN AS “ROOM INTEGRITY
TEST”) UPON COMPLETION.
BID INSTRUCTION NOTES FOR BIDDERS
1. FIRE SUPPRESSION CONTRACTOR TO PROVIDE FULL DESIGN-BUILD SUBMITTALS, INCLUDING:
A. COMPLETE NFPA 2001 DESIGN, CALCULATIONS, AND NOZZLE LAYOUT
B. CLEAN AGENT TANK PLACEMENT AND PIPE ROUTING
C. INTEGRATION WITH EXISTING FIRE ALARM AND HVAC SYSTEMS
D. ROOM INTEGRITY TEST REPORT PRIOR TO COMMISSIONING
SYSTEM PERFORMANCE REQUIREMENT:
1. “CLEAN AGENT SYSTEM SHALL ACHIEVE 10-MINUTE MINIMUM CONCENTRATION HOLD TIME AND FULLY PROTECT ALL IT EQUIPMENT WITHIN ROOM
TEMPERATURE LIMITS.”
SERVER ROOM GENERAL NOTES
Rev # Date Description
Job #
Drawn
Date
Owner #
Checked
186 N. 100 E. SUITE A
KAYSVILLE, UT 84037
(801) 882-7208 www.onyxdesigncollective.com
NOTE: THIS DRAWING IS INTENDED FOR A
24"X36" SHEET. IF IT HAS BEEN PRINTED ON
ANYTHING ELSE IT IS A REDUCED COPY.
PLEASE SCALE DRAWING ACCORDINGLY.
AT
T S
AT
UE FO
H
L
IC
E
N
SED ARCH
IT
E
C T
No. 8246979-0301
KINLEY C. PUZEY
/2
/2
:0
:2
P
M
G1.2
PROJECT
SPECS
CITY OF SOUTH SALT
LAKE
C
IT
Y H
A L
L
R D
F L O
O R
R E
N O
V A
T
IO
N
CheckerAuthor 02-20-2026
25.004
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
E M
O R
R
IS
A V
E S
O U
T H
S A
L T
L A
K E
U
T
02-20-2026
PROJECT SPECIFICATIONS
09-FINISHES
FINISH SCHEDULE: THE CONTRACTOR SHALL BE BOUND TO THE FINISH SCHEDULE PROVIDED FOR
ROOMS AND SPACES, BUT SHALL BE ALSO RESPONSIBLE TO PROVIDE OTHER MATERIALS NOT
DESIGNATED IN THE SCHEDULE IF REQUIRED IN THE FIELD TO CREATE A FINISHED PRODUCT AT
WALKS, FLOORS, CEILINGS, DOORS, WINDOWS, SOFFITS, TREADS, AND ALL OTHER FURRING,
LEVELING, AND PATCHING WHERE REQUIRED.
GYPSUM BOARD: INSTALL PER RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND
FINISHING OF GYPSUM BOARD, PER ANSI 97.1
METAL SUPPORT SYSTEM (WALL STUDS)
PROVIDE CHANNEL-SHAPED ROLL FORMED SHEET STEEL MEMBERS CONFORMING WITH ASTM C640, HOT DIPPED FINISH WHERE EXPOSED TO MOISTURE NOT LESS THAN 20 GA. PROVIDE 16 GA. AT
DOOR JAMBS.
PROVIDE ROLL HAT-SHAPED CHANNELS MINIMUM 25 GA. 7/8" DEEP WITH 1/2" HEMMED EDGES.
PROVIDE TIE WIRES OF GALVANIZED ANNEALED WIRES NOT LESS THAN 16 GA. PROVIDE GALVANIZED
HANGERS OF STEEL WIRE IN ACCORDANCE WITH ASTM C754.
PROVIDE JACK STUDS BETWEEN BOTTOM TRACK AND WINDOW AND/OR RELIEF SILLS BETWEEN
LINTELS AND HEADERS IN TOP TRACKS. PROVIDE BLOCKING AND FRAMING FOR ALL WALL MOUNTED
FINISH HARDWARE AND EQUIPMENT, INCLUDING DOOR STOPS.
PROVIDE DOUBLE BEAD TO BUTYL SEALANT AT FLOOR TRACKS. APPLY DOUBLE BEAD TO CEILING
TRACK AND TO STUDS ABUTTING OTHER CONSTRUCTION.
PROVIDE CHANNEL SHAPED BLOCKING SUPPORT OR GALVANIZED STRIP SUPPORT OF WALL-HUNG
CABINETS, EQUIPMENT, FIXTURES AND ACCESSORIES OF NOT LESS THAN 22 GA. MATERIAL PROVIDE
SUPPORT IN WALL OR PARTITION FRAMING SYSTEM WHEREVER WALL HUNG CABINETS AND
EQUIPMENT ARE INDICATED ON DRAWINGS. AND WHERE REQUIRED FOR MOUNTING OF
MISCELLANEOUS ITEMS REQUIRING BACKING.
SET FLOOR TRACKS IN ACCURATE LOCATIONS AND SECURELY ANCHOR IN ACCORDANCE WITH ASTM STANDARDS. ERECT STUDS ON 16" OR 24" (AS INDICATED) CENTERS AND SECURE TO TRACK. INSTALL HEAD TRACK IN ACCORDANCE WITH DETAILS. INSTALL BLOCKING, BRACING AND ANCHOR STRIPS;
LEAVE READY TO RECEIVE FINISH MATERIALS.
ERECT ALL COMPONENTS FOR CEILING AND SOFFIT FRAMING IN ACCURATE LOCATIONS AS
INDICATED TRUE TO LINE, LEVEL AND PLUMB, AND IN ACCORDANCE WITH APPLICABLE ASTM
STANDARDS AS REFERENCED ABOVE, USING A LASER LEVEL. ADJUST SUPPORTS, SPANS OR
OTHERWISE FOR INSTALLATION WITHIN SPECIFIED TOLERANCES.
PROVIDE KICK BRACING IN ACCORDANCE WITH INDUSTRY STANDARDS FOR WALL STUDS, CEILING
MEMBERS, DRAFT OR SMOKE STOPS AND CURTAIN WALLS.
GYPSUM WALL BOARD
PROVIDE GYPSUM WALL PANELS MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF ASTM
336.
PROVIDE METAL EDGE AND CORNER BEADS AT ENDS, EDGES AND CORNERS.
WATER RESISTANT GYPSUM WALL BOARD SHALL BE 5/8" THICK TAPERED AND ROUNDED EDGES AND
SHALL BE INSTALLED IN ALL WET AREAS AS INDICATED ON DRAWINGS.
PROVIDE FASTENERS IN ACCORDANCE WITH ASTM C646: UNLESS OTHERWISE NOTED OR INDICATED, PROVIDE TYPE "S" BUGLE HEAD SCREWS FOR ATTACHMENT OF WALL BOARD TO METAL FRAMING, AND TYPE "S" PAN HEAD SCREWS FOR ATTACHMENT OF FRAMING TO DOOR FRAMES.
PROVIDE ALL INCIDENTAL AND ACCESSORY MATERIALS, TOOLS, EQUIPMENT AND METHODS
REQUIRED FOR SATISFACTORY COMPLETION OF GYPSUM WALL BOARD CONSTRUCTION INCLUDING
ACCESS DOORS AND PANELS.
APPLY CONTINUOUS BEAD SEALANT AT ALL JOINTS OF WALL BOARD ABUTTING ADJACENT
CONSTRUCTION, INCLUDING AROUND FRAMED OPENINGS AND OTHER PROTRUSIONS THROUGH
WALL BOARD WHERE SEALANT IS EXPOSED. PROVIDE POLY-SULFIDE SEALANT; WHERE UNEXPOSED.
PROVIDE ACOUSTIC SEALANT.
APPLY PRE-FILL COMPOUND TO JOINTS IN ACCORDANCE WITH INDUSTRY STANDARDS. APPLY
EMBEDDING COMPOUND REINFORCING TAPE CENTERED OVER JOINT; APPLY SKIM COAT. AFTER
TAPING AND EMBEDDING COMPOUND IS DRY, APPLY SECOND COAT FILLING AND TAPER FLUSH WITH SURFACE: FIRE TAPE PENETRATIONS AT DEMISING WALLS, CORRIDOR ENVELOPE AND OTHER RATED
ASSEMBLIES.
PROVIDE FINAL FINISH THAT IS SMOOTH, WITHOUT DIVOTS, BUMPS, BOWS OR ANY OTHER SURFACE
BLEMISH. READY TO RECEIVE PAINT.
CUSTOM SKIP TROWELED FINISH WHERE SPECIFIED ON PLANS. COORDINATE FINISH WITH
ARCHITECT.
PAINTING
CONTRACTOR TO SUBMIT PAINTING DROPDOWN SAMPLES TO ARCHITECT FOR VERIFICATION AND
APPROVAL IN WRITING PRIOR TO FABRICATION.
PROVIDE PAINT FINISHES FOR BUILDING AND OTHER SURFACES AS SCHEDULED ON DRAWINGS OR
AS SPECIFIED HEREINAFTER INCLUDING SEALING OF CONCRETE FLOOR AT CORRIDOR AND
STOCKROOM. NO PAINT FINISH IS REQUIRED ON ITEMS HAVING COMPLETE FACTORY FINISH, EXCEPT
AS MAYBE SPECIFIED HEREINAFTER: PUTTY AND/OR SEALANT AT ALUMINUM WINDOWS: NON-
FERROUS METAL UNLESS SPECIFICALLY MENTIONED IN THE PAINTING SCHEDULE: STAINLESS STEEL;
INTERIOR OR EXTERIOR OF EXISTING BUILDING. NO PAINTING IS REQUIRED FOR INSULATING PIPING, EXCEPT WHERE EXPOSED IN FINISH, NON-MECHANICAL ROOM SPACES.
PROTECT WORK OF OTHER TRADES FROM DAMAGE AND DEFACEMENT CAUSED BY THIS WORK.
REPAIR ANY DAMAGE CAUSED BY THE WORK OF THIS SECTION. REMOVE ELECTRICAL OUTLET AND
SWITCH PLATES, MECHANICAL DIFFUSERS, GRILLES, ESCUTCHEONS, REGISTERS, SURFACE
HARDWARE, FITTINGS AND FASTENINGS PRIOR TO COMMENCING THE WORK, STORE, CLEAN AND
REPLACE UPON COMPLETION.
PAINT CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IF ANY SURFACE TO BE PAINTED OR STAINED IS FOUND TO BE UNSUITABLE TO PRODUCE PROPER FINISH. APPLY NO FINISH MATERIAL
UNTIL THE UNSUITABLE SURFACES HAVE BEEN MADE SATISFACTORY.
FINISH WORK SHALL BE UNIFORM, OF APPROVED COLOR, SMOOTH AND FREE FROM RUNS. MAKE
ENDS OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WHERE HIGH GLOSS
ENAMEL IS USED, LIGHTLY SAND UNDERCOAT TO OBTAIN A SMOOTH FINISH COAT.
PROVIDE ALL NEWLY PAINTED SURFACES WITH (1) COAT TINTED PRIMER AND A MINIMUM OF (2)
COATS FINAL COLOR COAT, (UNLESS OTHERWISE RECOMMENDED BY MANUFACTURER'S
SPECIFICATIONS). TO PROVIDE A SOLID, UNIFORM AND DURABLE FINISH. ALLOW PROPER DRYING
TIME BETWEEN COATS.
DELIVER ALL PAINT TO JOBSITE IN UNOPENED CONTAINERS BEARING THE MANUFACTURER'S LABEL, AND SHOWING PAINT TYPE, SHEEN AND COLOR.
PAINT TYPES USED SHALL BE THOSE SPECIFICALLY RECOMMENDED BY THE MANUFACTURER FOR
THE MATERIAL TO WHICH THEY WILL BE APPLIED. PAINTING CONTRACTOR SHALL FOLLOW
MANUFACTURER'S INSTRUCTIONS FOR PROPER APPLICATION OF THE PAINT.
ALL SURFACES TO BE PAINTED SHALL BE THOROUGHLY CLEANED, AND PREPARED FOR PAINTING PRIOR TO APPLICATION OF PAINT. PROVIDE VENTILATORS AS REQUIRED TO PREVENT BUILD-UP OF
FUMES.
SANDPAPER ALL NEW WOOD TO SMOOTH AND EVEN SURFACE AND DUST OFF. AFTER PRIMING COAT HAS BEEN APPLIED, THOROUGHLY FILL ALL NAIL HOLES AND OTHER SURFACE IMPERFECTIONS WITH
PUTTY TINTED WITH PRIMER OR STAIN TO MATCH WOOD COLOR. SAND ALL WOODWORK BETWEEN
COATS TO A SMOOTH SURFACE.
PRIME ALL SURFACES WHICH RECEIVE PAINT PRIOR TO APPLICATION OF FINAL FINISH, IN
ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
BACK PRIME ALL EXTERIOR AND INTERIOR WOOD AND TRIM PRIOR TO INSTALLATION. THOROUGHLY
CLEAN SURFACES AND APPLY NO FINISH UNLESS SURFACES ARE DRY AND READY FOR
APPLICATION. SAND SURFACES OF TRIM SMOOTH AND WIPE CLEAN. AFTER STAIN COAT HAS BEEN APPLIED. FILL CRACKS AND HOLES WITH PLASTIC WOOD OR PUTTY. IF STAIN HAS BEEN USED, TINT
CRACK FILLER TO MATCH; PRIME BACKS OF TRIM, PRIME BARE WOOD SCHEDULED TO RECEIVE
PAINT FINISH; FINISH NAIL HOLES, CRACKS AND OTHER IMPERFECTIONS WITH PUTTY AND SAND
SMOOTH.
AT COMPLETION, TOUCH-UP AND RESTORE FINISH WHERE DAMAGED AND LEAVE ALL SURFACES IN GOOD AND CLEAN CONDITION. PROVIDE FOR MULTIPLE SITE VISITS AS REQUIRED FOR TOUCH-UP
AND REFINISHING.
OTHER PAINT MANUFACTURER'S MAY NOT BE SUBSTITUTED.
01-GENERAL REQUIREMENTS
DRAWINGS: THE DRAWINGS ARE ONLY INTENDED TO PARTIALLY DESCRIBE
THE OVERALL SCOPE OF WORK. CONTRACTORS SHALL FIELD VERIFY
EXISTING CONDITIONS AND ALERT ARCHITECT IN ADVANCE TO ANY
UNFORESEEN CONSTRUCTION DIFFICULTIES BEFORE BEGINNING WORK
OR WORKING ON THE AFFECTED PORTION OF THE WORK.
PERMITS/FEES: CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS
NECESSARY OTHER THAN THE BUILDING PERMIT. CONTRACTOR SHALL
ALSO PAY FOR ALL OTHER CHARGES, FEES, OR COSTS CHARGED BY THE
BUILDING AND CONSTRUCTION DEPARTMENTS, UTILITY AGENCIES, OR
PRIVATE COMPANIES WHICH REQUIRE SUCH COSTS FOR, OR PRIOR TO,
INSTALLATIONS.
CODES: NOTHING IN THE DRAWINGS AND/OR THE SPECIFICATIONS SHALL
BE CONSTRUED TO PERMIT AN INSTALLATION IN VIOLATION OF APPLICABLE
CODES AND / OR RESTRICTIONS. SHOULD ANY CHANGES IN THE
DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITH APPLICABLE
CODES AND / OR REQUIREMENTS, THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT AT ONCE AND CEASE WORK ON ALL PARTS OF THE CONTRACT
WHICH ARE AFFECTED. THE WORK TO BE PERFORMED UNDER THIS
CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES,
REGULATIONS, RESTRICTIONS, REQUIREMENTS, AND CODES.
ALL WORK AS SHOWN ON THE CONSTRUCTION DOCUMENTS IS PER THE
2021 INTERNATIONAL BUILDING CODE AND THE 2021 INTERNATIONAL FIRE
CODE AS ADOPTED. IT IS THE INTENT OF THESE DOCUMENTS TO COMPLY
THERETO. WORK PERFORMED IN VIOLATION OF LOCAL CODES OR
ORDINANCES SHALL BE CORRECTED AT NO EXPENSE TO THE OWNER.
CONFLICT: IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR
STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DOES NOT
EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES,
THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF
ALL CONFLICTS.
DIMENSIONS: DIMENSIONS ARE SHOWN TO FACE OF CONCRETE, FACE OF
STUD AT EXTERIOR WOOD-FRAMED WALLS, FACE OF STUD AT INTERIOR
WALLS AND CENTERLINE OF OPENINGS, UNLESS DETAILED OTHERWISE ON
DRAWINGS. FRAMING DIMENSIONS HAVE BEEN ROUNDED TO THE
NEAREST ONE HALF INCH. CONTRACTOR SHOULD VERIFY CONDITION
BEFORE FRAMING STARTS.
DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS
ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENT. NOTIFY THE
ARCHITECT IF ANY DISCREPANCIES ARE FOUND.
SUBCONTRACTORS SHALL VERIFY SIZES AND LOCATIONS OF ALL
OPENINGS FOR WORK. THE SUBCONTRACTOR SHALL VERIFY ALL ROUGH-
IN DIMENSIONS FOR THE EQUIPMENT FURNISHED AND INSTALLED BY
THEMSELVES OR OTHERS.
THE CONTRACTOR AND SUBCONTRACTOR SHALL CONSULT THE PLANS OF
ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS, CEILINGS FOR
ROOF DUCTS, PIPES, CONDUITS, CABINETS AND EQUIPMENT; AND SHALL
VERIFY THE SIZES AND LOCATIONS WITH SUBCONTRACTORS.
02-EXISTING CONDITIONS
EXISTING UTILITIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR
VERIFICATION OF ALL EXISTING UTILITIES. EXISTING UTILITIES SHOWN
HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR
CONVENIENCE ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ADDITIONAL UTILITY LOCATIONS NOT SHOWN. CARE SHOULD BE TAKEN TO
AVOID DAMAGE OR DISTURBANCE TO EXISTING UTILITIES.
REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY
DISPOSE OF THEM OFF-SITE UNLESS INDICATED TO BE REMOVED AND
SALVAGED OR REMOVED AND REINSTALLED.
REMOVE AND SALVAGE: CAREFULLY DETACH FROM EXISTING
CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO
OWNER.
REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING
CONSTRUCTION, PREPARE FOR REUSE, AND REINSTALL WHERE
INDICATED.
EXISTING TO REMAIN: EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT
TO BE PERMANENTLY REMOVED AND THAT ARE NOT OTHERWISE
INDICATED TO BE REMOVED, REMOVED AND SALVAGED, OR REMOVED AND
REINSTALLED.
NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS
AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION.
HAZARDOUS MATERIALS: IT IS NOT EXPECTED THAT HAZARDOUS
MATERIALS WILL BE ENCOUNTERED IN THE WORK. IF SUSPECTED
HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB;
IMMEDIATELY NOTIFY ARCHITECT AND OWNER. HAZARDOUS MATERIALS
WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.
SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS
INDICATED TO DETERMINE EXTENT OF SELECTIVE DEMOLITION REQUIRED.
ANY UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL
ELEMENTS THAT CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE
ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF
CONFLICT. PROMPTLY SUBMIT A WRITTEN REPORT TO ARCHITECT.
PERFORM AN SURVEY OF CONDITION OF BUILDING TO DETERMINE
WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL
DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF STRUCTURE
OR ADJACENT STRUCTURES DURING SELECTIVE BUILDING DEMOLITION
OPERATIONS.
PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER
TO LOWER LEVEL. COMPLETE SELECTIVE DEMOLITION OPERATIONS
ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING
MEMBERS ON THE NEXT LOWER LEVEL.
NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO
DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO
DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. USE
HAND TOOLS OR SMALL POWER TOOLS DESIGNED FOR SAWING OR
GRINDING, NOT HAMMERING AND CHOPPING, TO MINIMIZE DISTURBANCE
OF ADJACENT SURFACES. TEMPORARILY COVER OPENINGS TO REMAIN.
CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED
SURFACES TO AVOID MARRING EXISTING FINISHED SURFACES.
DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF
FLAMMABLE MATERIALS. AT CONCEALED SPACES, SUCH AS DUCT AND
PIPE INTERIORS, VERIFY CONDITION AND CONTENTS OF HIDDEN SPACE
BEFORE STARTING FLAME-CUTTING OPERATIONS. MAINTAIN PORTABLE
FIRE-SUPPRESSION DEVICES DURING FLAME-CUTTING OPERATIONS.
MAINTAIN ADEQUATE VENTILATION WHEN USING CUTTING TORCHES.
LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND
MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING
WALLS, FLOORS, OR FRAMING.
DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY.REMOVE AND
TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE ON
ADJACENT SURFACES AND AREAS.
03-CONCRETE
NOT USED
04-MASONRY
NOT USED
05-METALS
DISSIMILAR METALS: PROVIDE GALVANIC INSULATION BETWEEN DISSIMILAR METALS.
PAINT: CONTRACTOR SHALL PRIME AND PAINT THE INTENDED PAINTABLE METAL
STACKS, METAL BEAM/POST CONNECTIONS, VENTS GRILLS, OR LOUVERS WHICH
PROJECT THROUGH WALLS OR ROOF AND IN VIEW. COLOR TO BE SELECTED BY
ARCHITECT
PROVIDE ALL MISCELLANEOUS METAL ITEMS INCLUDING MATERIALS, FABRICATIONS,
FASTENINGS, AND ACCESSORIES REQUIRED FOR FINISHED INSTALLATION AS
INDICATED AND SPECIFIED.
STEEL SHALL BE ASTM A366 AMERICAN OPEN HEARTH SHEET STEEL, FREE FROM
SCALE AND PITTING AND OTHER DEFECTS AFFECTING APPEARANCE.
TUBING SHALL CONFORM TO REQUIREMENTS OF ASTM A500 OR A501 AS APPROVED.
WHERE METAL ITEMS ARE TO BE ERECTED AND IN CONTACT WITH DISSIMILAR
MATERIALS. PROVIDE CONTACT SURFACES WITH COATING OF AN IMPROVED ZINC
CHROMATE PRIMER IN MANNER TO OBTAIN NOT LESS THAN 1.0 MIL DRY FILM
THICKNESS.
SHEET STEEL SHALL CONFORM TO REQUIREMENTS OF ASTM A606.
CARBON STEEL BARS SHALL CONFORM TO REQUIREMENTS OF ASTM A321.
ALUMINUM EXTRUSIONS SHALL CONFORM TO ASTM B221.
FASTENERS SHALL BE AS REQUIRED FOR ASSEMBLY AND INSTALLATION OF
FABRICATED ITEMS.
BOLTS SHALL BE LOW CARBON STEEL EXTERNALLY AND INTERNALLY THREADED
FASTENERS CONFORMING WITH REQUIREMENTS OF ASTM A307. INCLUDE
NECESSARY NUTS AND PLAIN HARDENED WASHERS. FOR MEMBERS FOR SUPPORT
OF STRUCTURAL MEMBERS OR CONNECTION THERETO. USE FASTENERS
CONFORMING WITH ASTM A325. FOR STAINLESS STEEL AND NON-FERROUS ITEMS,
USE TYPE 302 AND 304 STAINLESS STEEL FASTENERS.
MISCELLANEOUS MATERIALS: PROVIDE ALL INCIDENTAL ACCESSORY MATERIALS,
TOOLS, METHODS, AND EQUIPMENT REQUIRED FOR FABRICATION AND INSTALLATION
OF MISCELLANEOUS METAL ITEMS AS INDICATED ON DRAWINGS.
\VERIFY DIMENSIONS PRIOR TO FABRICATION OR CASTING, FORM METAL ITEMS TO
ACCURATE SIZES AND CONFIGURATIONS AS INDICATED ON DRAWINGS AND
OTHERWISE REQUIRED FOR PROPER INSTALLATION; FABRICATE WITH ALL LINES
STRAIGHT AND ANGLES SHARP, CLEAN AND TRUE; DRILL, COUNTERSINK, TAP, AND
OTHERWISE PREPARE ITEMS FOR CONNECTION WITH WORK OF OTHER TRADES
MAKE. PERMANENT CONNECTIONS BY WELDING AND GRIND ALL EXPOSED WELDS
SMOOTH TO MATCH ADJACENT SURFACES; ROUGH JOINT SURFACES NOT
PERMITTED AVOID USING BOLTS AND SCREWS UNLESS SPECIFICALLY INDICATED OR
APPROVED; WHEN USED, DRAW UP TIGHT AND TIE THREADS TO PREVENT
LOOSENING.
\ALL FERROUS METAL ITEMS SHALL BE SHOP FINISHED. TOUCH-UP OR REPAIR
DAMAGED AREAS PRIOR TO INSTALLATION WITH SAME MATERIAL.
PROVIDE CONTACT SURFACES WITH CONCRETE MASONRY OR OTHER DISSIMILAR
MATERIALS WITH A MINIMUM ONE POINT ZERO (1.0) MIL DRY THICKNESS OF AN
APPROVED ZINC CHROMATE PRIMER.
PROVIDE ALL STEEL BLOCKING AND BRACING IN METAL STUD FRAMED PARTITIONS
NECESSARY FOR A COMPLETE INSTALLATION. INCLUDE AS REQUIRED FOR SUPPORT
OF ALL WALL-MOUNTED EQUIPMENT AND FABRICATIONS AS INDICATED ON
DRAWINGS. PROVIDE SUPPORTS AT JAMBS OF DOORS AND ELSEWHERE, AS
REQUIRED.
FABRICATE ALL MISCELLANEOUS FRAMING AND BRACING ITEMS TO DETAIL OF
STRUCTURAL SHAPES, PLATES AND BARS; WELD JOINTS WHERE PRACTICAL;
PROVIDE BOLTS AND OTHER CONNECTION DEVICES REQUIRED. INCLUDE
ANCHORAGES, CLIP ANGLES, SLEEVES, ANCHOR PLATE, AND SIMILAR DEVICES,
WHETHER IMPLIED OR INDICATED. SET ACCURATELY IN POSITION AS REQUIRED AND
ANCHOR SECURELY TO BUILDING CONSTRUCTION WITH FASTENERS APPROPRIATE
TO THE INSTALLATION.
06-WOOD, PLASTICS, COMPOSITES
PRESSURE TREATED WOOD: ALL WOOD IN CONTACT WITH CONCRETE TO BE
PRESSURE TREATED PER INTERNATIONAL BUILDING CODE.
BLOCKING: PROVIDE WOOD BACKING, FURRING, STRIPPING, OR BLOCKING
REQUIRED FOR INSTALLATION AND ATTACHMENT OF WORK OF ALL OTHER TRADES.
1. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS. MOISTURE
CONTENT NOT MORE THAN 19%.
PROVIDE ALL NECESSARY ROUGH HARDWARE IN SIZES IN QUANTITIES REQUIRED BY
LOCAL CODE OR APPROVED BY ARCHITECT.
USE FINISH OR CASING NAILS FOR EXPOSED WORK; USE TYPE "S" TRIM HEAD
SCREWS FOR ATTACHMENT OR WOOD TRIM TO METAL STUDS, RUNNERS, OR
FURRING.
RELIEVE BACKS OF WOOD TRIM; KERF BACKS OF MEMBERS MORE THAN 5" WIDE AND
1" NOMINAL THICKNESS; EASE ALL EXTERNAL CORNERS.
INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY
CONDITION FOR INSTALLATION.
USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR
APPLICATION; INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOST CURRENT
PRINTED APPLICATION INSTRUCTIONS.
PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE
INSTALLATION. REPLACE DAMAGED SURFACES.
REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S
RECOMMENDED SOLVENT AND CLEANING PROCEDURES.
FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOUND.
INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS, WITH THE
FOLLOWING CONSIDERATIONS AND REQUIREMENTS:
A. INSTALL ALL MATERIAL WITH TIGHT JOINTS. MITER CASINGS AND MOLDINGS.
B. ALL RUNNING TRIM ONE (1) PIECE UP TO 10'-0". MATCH GRAIN AND COLOR
PIECE TO PIECE.
C. USE FINISH NAILS EXCEPT WHERE SCREWS ARE SPECIFICALLY CALLED FOR
OR WHERE SCREWS DO NOT SHOW. SET FASTENERS FOR PUTTYING. WHERE
SCREW ATTACHMENT IS REQUIRED, SPACE SCREWS AT EQUAL INTERVALS;
SINK AND PUTTY IN FINISHED WOOD SURFACES.
D. ALL MEMBERS AND LINES SHALL BE LEVEL AND PLUMB. SELECT AND CUT
MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS.
E. FINISH EXPOSED SURFACES SMOOTH, FREE FROM TOOL AND MACHINE
MARKS.
F. EASE ALL EXPOSED WOOD EDGES 1/16" MINIMUM RADIUS.
G. INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS.
ENSURE THAT ANY AND ALL WOOD AND PLASTICS USED COMPLY WITH ALL
MUNICIPALITIES REQUIREMENTS FOR FLAMMABILITY AND SMOKE DEVELOPED
RATINGS.
THE SUB-CONTRACTOR SUBMIT SAMPLE OF ALL FINISHES AND PREPARE SHOP
DRAWINGS FOR ALL MILLWORK AND SUBMIT TO CONTRACTOR AND ARCHITECT TO
GAIN APPROVAL IN WRITING PRIOR TO FABRICATION OR INSTALL.
07-THERMAL AND MOISTURE PROTECTION
OPENINGS: ALL OPENINGS TO BE CAULKED, SEALED, OR WEATHER-STRIPPED
WEATHER PROTECTION: PROVIDE WEATHER PROTECTION PER INTERNATIONAL
BUILDING CODE 1404. INSTALL WEATHER RESISTIVE BARRIER PROTECTING WALL
STRUCTURE AND FLASHING AND COUNTER-FLASHING AT EXTERIOR OPENINGS TO MAKE
THEM WEATHERPROOF.
CAULKING AND SEALANT: USE PRIMERS AS REQUIRED BY MANUFACTURER, BACKING
RODS OR TAPE AS RECOMMENDED BY MANUFACTURER. USE POLYURETHANE SEALANT
AT CONCRETE FLOOR AND SIDEWALK JOINTS, ALL OTHER LOCATIONS USE
POLYSULFIED OR SILICONE UNLESS NOTED OTHERWISE. APPLY TWO BEADS OF
SEALANT BETWEEN SOLE PLATES AND FLOOR (IE SILICONIZED LATEX, FOAM GASKET,
OR EQUIVALENT). U.N.O.
VAPOR BARRIERS: CONTINUOUS APPROVED VAPOR BARRIERS SHALL BE INSTALLED ON
THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED.
INSULATION: ALL INSULATION MATERIALS INCLUDING FACINGS, SUCH AS VAPOR
BARRIERS OR BREATHER PAPERS INSTALLED WITHIN FLOOR-CEILING ASSEMBLIES,
WALLS, CRAWL SPACES OR ATTICS SHALL HAVE A FLAME-SPREAD RATING NOT TO
EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE
ASTM E 84. SEC. IBC 719 SEE EXEMPTIONS. ALL FOAM PLASTIC INSULATION USED IN
BUILDING CONSTRUCTION SHALL BE INSTALLED IN ACCORDANCE WITH IBC SEC. 719.
PROVIDE NON-SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL
SPECIFICATIONS TTS-1543 OR FS TT-S-230 TYPE "II", CLASS "A". PROVIDE ACOUSTICAL
SEALANT WHICH SHALL BE NON-HARDENING, NON-DRYING SYNTHETIC RUBBER SEALING
COMPOUND WITH MINIMUM 90% SOLIDS. USE AT ALL INTERIOR JOINTS AT INNER
SECTIONS BETWEEN PLANES. AROUND DOOR AND WINDOW FRAMES PRIMER SHALL BE
MADE OR RECOMMENDED BY SEALANT MANUFACTURER FOR THE SPECIFIC
CONDITIONS AND SUBSTRATES.
PROVIDE BACKING MATERIAL BY DOW "ETHAFOAM" OR APPROVED EQUAL. APPLY
SEALANT OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL
JOINTS AND VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT BE
ACCEPTABLE.
08-OPENINGS
EXIT DOORS: EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF
A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. IBC SEC. 1003.3.1.
GLASS: GLASS IN THE FOLLOWING LOCATIONS TO BE SAFETY GLASS: ALL GLASS
DOORS, SLIDING, PATIO DOORS, STORAGE DOORS, SHOWER AND BATHTUB
ENCLOSURES, WINDOWS WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS
WITHIN A 24 INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION,
AND FIXED PANELS GREATER THAN 9 SQUARE FEET WITH LOWEST EDGE LESS THAN 18
INCHES ABOVE THE FLOOR. (SEE EXCEPTIONS) IBC SEC. 2406.2. ALL GLAZING IN
LOCATIONS SUBJECT TO HUMAN IMPACT SHALL BE SAFETY GLAZING PER IBC SEC.
2406.2
HARDWARE: PROVIDE COMMERCIAL GRADE DOOR/WINDOW HARDWARE AT ALL
OPERABLE WINDOWS AND DOORS.
DOOR HARDWARE FOR ACCESS CONTROLS TO BE COORDINATED WITH CITY IT DEPT.
AND CITY AMAG VENDOR.
THE SUB-CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR FRAMES AND
SUBMIT TO CONTRACTOR AND ARCHITECT TO GAIN APPROVAL IN WRITING PRIOR TO
FABRICATION OR INSTALL.
CONTRACTOR TO SUBMIT DOOR FINISH SAMPLE TO ARCHITECT FOR APPROVAL IN
WRITING PRIOR TO FABRICATION.
PROVIDE PRE-FINISHED STEEL DOOR FRAMES, SIZES AS INDICATED IN DRAWINGS BY
TIMELY INDUSTRIES OR EQUAL. USE MATERIAL FREE FROM DEFECTS IN MATERIAL AND
ACCORDING TO PROJECT SPECIFICATIONS FOR PRE-ENGINEERED OPENING SYSTEMS
WITH PROVEN DURABILITY OF FACTORY FINISHES ALLOWING FOR BENDING AND
SHAPING OF MATERIAL AFTER FINISH IS APPLIED. USE ONLY INSTALLERS FAMILIAR WITH
INSTALLATION OF PRE-FINISHED OPENING SYSTEMS AND APPLIED CASING FRAME
INSTALLATION. PROVIDE MATERIALS:
PROVIDE REINFORCEMENT AND ACCESSORIES AS REQUIRED BY MANUFACTURE
FOLLOWS:
A. PROVIDE REINFORCEMENTS SHIPPED LOOSE TO PROJECT SITE FOR HARDWARE
APPLICATION TA-10 - REGULAR ARM CLOSERS, CASING MOUNTED
COORDINATOR. TA-12 - PARALLEL ARM CLOSERS, RIM EXIT DEVICE STRIKES,
OTHER STOP MOUNTED SURFACE HARDWARE
B. PROVIDE HINGE REINFORCEMENT (TA-11) OF 14 GAGE STEEL PIERCED TO
CREATE DEPTH OF THREAD FOR HINGE SCREWS EQUAL TO OR EXCEEDING 7
GAGE STEEL.
C. SILENCERS: TA-5 VINYL, 2 PER FRAME, CLEAR STICK-ON TYPE.
D. GLASS STOPS: TA-14 REMOVABLE ROLLED STEEL, SHAPE, BUTTED ENDS. PRE-
PUNCH AND COUNTERSINK FOR FLAT HEAD TEK SCREWS.
E. ADJUSTABLE STRIKES: EMBOSS FRAMES FOR TA-1 STRIKE FOR CYLINDRICAL
LOCK. PROVIDE TA-1 STRIKE IN FINISH COMPATIBLE WITH HARDWARE FINISH.
(ANSI 2 ¾” T STRIKE SUPPLIED WITH CYLINDRICAL LOCK CANNOT BE USED WITH
STANDARD FRAME BECAUSE OF UNIQUE STRIKE LOCATION AND SCREW
PIERCING METHOD)
F. PREPARE FRAMES FOR ASA 4-7/8” STRIKES WHERE REQUIRED. PROVIDE
MINIMUM ¼” DEPTH OF THREADS IN FACTORY TAPPED SCREW HOLES
G. INSTALLATION FASTENERS FOR INTERIOR FRAMES: #6 DRYWALL TYPE LENGTH
SUFFICIENT TO PENETRATE STUDS OR STRUCTURE AT LEAST ½”.1
OPENINGS FOR SINGLE SWING, PAIR, BORROWED LIGHT AND SIDELIGHT FRAMES TO BE
PRE-CUT, NOTCHED AND FABRICATED AT THE MANUFACTURER'S FACILITY.
PROVIDE MINIMUM 14 GAGE HINGE REINFORCEMENT PLATE TAPPED FOR MACHINE
SCREWS SUPPLIED WITH HINGES. HINGE PLATE TO BE MECHANICALLY ATTACHED TO
HINGE EMBOSS ON FRAME
CASING CLIPS: FABRICATE FRAMES WITH FACTORY APPLIED, HEAT TREATED CLIPS TO
ENSURE NO DEFLECTION IN THE CLIP UPON APPLICATION OR REMOVAL OF CASING.
ATTACHMENT CLIPS MAY NOT BE OF SAME MATERIAL AS FRAME
PROVIDE NOTCHES, TABS AND/OR STOPS FOR POSITIVE ALIGNMENT OF FRAME PARTS
AT ALL CORNERS. MULLIONS TO BE NOTCHED AS REQUIRED TO PROVIDE TIGHT JOINTS.
PROVIDE MANUFACTURER'S STANDARD MULLION BRACKETS FOR POSITIVE
CONNECTION OF FRAME AND MULLION PARTS
PROVIDE MANUFACTURER'S STANDARD STEEL GLASS STOP PRE-CUT TO EXACT
LENGTH. FIRE RATED GLAZED OPENINGS TO HAVE HOLE FOR INSTALLATION SCREW
WITHIN 2” OF EACH END OF STOP PIECE.
PROVIDE INSERT CHANNEL FULL WIDTH OF BORROWED LIGHTS INSTALLED ON FINISH
FLOOR. PROVIDE FULL WIDTH HEAD CHANNEL FOR CEILING HEIGHT UNITS.
PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR CEILING INSERT CHANNEL FOR
CEILING HEIGHT FRAMES
INSTALLED FRAME ASSEMBLY TO CONFORM TO NFPA 80. ATTACH APPROVED MYLAR
LABEL TO EACH FIRE-RATED FRAME INDICATING FIRE RATING DETAILS.
PRE-FINISHED WITH FACTORY APPLIED IMPACT RESISTANT, POLYESTER BAKED ENAMEL
FINISH OR OPTIONAL ELECTROSTATIC APPLIED WATER BASED PAINT SYSTEM. FRAMES
FOR HIGH HUMIDITY AREAS TO BE ELECTRO GALVANIZED PRIOR TO PRE-FINISHING. SEE
2.02.B FOR SPECIFIC LOCATIONS. CASING FINISHES: STEEL: PRE-FINISHED WITH
FACTORY APPLIED IMPACT RESISTANT, POLYESTER BAKED ENAMEL FINISH. COLORS:
AS SPECIFIED ON FINISH SCHEDULE IN DRAWINGS.
INSTALL FRAMES IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS:
A. ANCHOR FRAMES WITH SCREWS LOCATED AT EVERY CASING CLIP OR EVERY
11” AS SHOWN ON MANUFACTURER'S INSTRUCTIONS. FIELD VERIFY QUANTITY
AND LOCATION OF FASTENERS PRIOR TO INSTALLING CASING.
B. INSTALL PRE-FINISHED FRAMES NEAR END OF THE PROJECT AFTER WALL
PAINTING AND WALL COVERINGS ARE APPLIED.
C. COORDINATE INSTALLATION OF GLASS AND GLAZING IN GLAZED UNITS.
D. COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION OF HARDWARE
SPECIFIED
E. TOUCH-UP BLEMISHES ON FINISHED FRAMES WITH FACTORY PREPARED TOUCH
UP PAINT.
TILE
INSTALL TILE IN AREAS INDICATED. USE ADHESIVES AND APPLY ONLY AS RECOMMENDED BY
MANUFACTURER AND IN ACCORDANCE WITH INDUSTRY STANDARDS.
INSTALLERS MUST BE SPECIALISTS WITH A MINIMUM OF TWO (2) YEARS EXPERIENCE.
ALL INSTALLATION SHALL CONFORM TO THE LATEST APPLICABLE TILE COUNCIL OF AMERICA AND
ANSI STANDARDS.
DO NOT COMMENCE INSTALLATION UNTIL SUBSTRATE HAS BEEN MADE SUITABLE FOR TILE
INSTALLATION. REVIEW ALL AREAS TO RECEIVE TILE FLOORING (PRIOR TO SUBMITTING
ESTIMATE) TO DETERMINE THE REQUIRED EXTENT OF SUBFLOOR PREPARATION.
SET AND GROUT TILE WHEN AMBIENT TEMPERATURE IS AT LEAST 50' AND RISING. ALIGN ALL
JOINTS AND CORNERS. CLEAN METAL AND WOOD SURFACES AND CONCRETE FLOORS,
REMOVING ALL FOREIGN MATTER AND CONTAMINANTS SUCH AS GREASE, OIL, DUST, WATER,
SURFACE DIRT, OLD SEALANTS OR GLAZING COMPOUNDS, AND PROTECTIVE COATINGS. METAL
SHALL BE CLEANED BY MECHANICAL OR SOLVENT PROCEDURES.
INSTALL TILE TO CONCRETE SUBSTRATE PER TCA STANDARD F113-89 WITH UNIFORMLY SPACED JOINTS, TO PATTERN INDICATED IN THE DRAWINGS. VERIFY LAYOUT AND CUTS WITH PROJECT
MANAGER PRIOR TO COMMENCEMENT OF WORK. CUT TILE AT WALL INTERSECTIONS FOR
CONCEALMENT BY BASE WHERE APPLICABLE. VARY MORTAR THICKNESS, AS NECESSARY, TO
ACCOMMODATE VARIATIONS IN THE TILE THICKNESS AND SLOPE.
CLOSE AREAS IN WHICH TILE IS BEING PLACED TO TRAFFIC AND OTHER WORK. KEEP AREA
CLOSED UNTIL TILE IS FIRMLY SET. PROTECT FLOORING FROM DAMAGE. REPLACE DAMAGED TILE
AT NO ADDITIONAL COST TO OWNER.
INSTALL TILE TO WOOD SURFACES AND ALUMINUM GLAZING CHANNEL AND METAL BASE WITH
DOWN CORNING 795 SILICONE BUILDING SEALANT, BEADS AT 6" ON CENTER MAXIMUM.
GROUT FLUSH WITH TILE EDGES. WIPE TILES WITH CHEESE CLOTH INSTEAD OF SPONGE. DAMP
CURE PER MORTAR AND GROUT MANUFACTURER'S RECOMMENDATIONS.
SEAL TILE PER MANUFACTURER'S WRITTEN INSTRUCTIONS WITH SEALER RECOMMENDED FOR
THE TILE INSTALLED. DOUBLE SEAL ALL JOINTS.
CARPET TILE
CONTRACTOR TO SUBMIT SAMPLE TO ARCHITECT FOR VERIFICATION AND APPROVAL PRIOR TO
ORDERING OR INSTALLING MATERIAL.
LEVELING COMPOUND - LATEX TYPE AS RECOMMENDED BY CARPET MANUFACTURER AND IS
COMPATIBLE WITH CARPET ADHESIVE AND CURING/SEALING COMPOUND ON CONCRETE.
RELEASABLE PRESSURE SENSITIVE TYPE ADHESIVE - USE THE FOLLOWING AS RECOMMENDED
BY THE CARPET MANUFACTURER WHICH WILL ALLOW REMOVAL OF CARPET AT ANY TIME
WITHOUT DAMAGE OR ADHERENCE TO CARPET: N5100 LOW VOC (NO SOLVENTS) CARPET TILE
ADHESIVE.
PRIOR TO INSTALLATION CRACKS 1/16 INCH OR MORE, HOLES, UNEVENNESS AND ROUGHNESS
MUST BE FILLED, LEVELED AND MADE SMOOTH WITH A COMPATIBLE LATEX FLOOR PATCHING
COMPOUND. PRIOR TO FILLING, THE FLOOR MUST BE SWEPT CLEAN OF ALL LOOSE GRANULAR
DEBRIS. AFTER FILLING, ALLOW FILLER TO DRY.
AREAS TO BE CARPETED MUST BE PRE-HEATED AT A MINIMUM OF 68º F. FOR 72 HOURS PRIOR TO
INSTALLATION WITH THE RELATIVE HUMIDITY NOT MORE THAN 65%. A MINIMUM TEMPERATURE
OF 50º F. SHALL BE MAINTAINED THEREAFTER.
PROVIDE 3% OVERAGE OF CALCULATED YARDAGE FOR EACH TYPE OF CARPET (CALCULATED
YARDAGE SHALL INCLUDE CARPET NEEDED FOR COMPLETE INSTALLATION PLUS WASTE AND
USABLE SCRAPS).
CARPET SHALL BE TESTED IN ACCORDANCE TO NFPA STANDARD 253 AND BE CLASS I (0.45
WATTS/CM2) IN CORRIDORS, EXIT ENCLOSURES, EXIT PASSAGEWAYS AND CLASS II (0.22
WATTS/CM2) IN ALL ROOMS AND AREAS.
SUSPENDED ACOUSTICAL CEILING
CEILING TILE SHALL BE LISTED AND TESTED ACCORDING TO ASTM E84 AND HAVE A FLAME
SPREAD OF 0-25 AND A SMOKE INDEX OF 0-450. WHERE TILE IS A COMPONENT OF A PLENUM
SYSTEM IT SHALL HAVE A FLAME SPREAD OF 0-25 AND A SMOKE INDEX OF 0-50.
SYSTEM COMPONENTS SHALL CONFORM TO ASTM C635 INTERMEDIATE DUTY AND UBC
STANDARD 47-18 INTERMEDIATE DUTY. INSTALLATION OF SYSTEMS SHALL CONFORM TO ASTM
C636, WITH A DEFLECTION OF NOT MORE THAN 1/360 OF THE SPAN. FURNISH AND INSTALL ALL
LABOR AND MATERIALS FOR COMPLETE ACOUSTICAL CEILING. REVIEW JOB SCHEDULE TO
VERIFY INSTALLATION DATES AND MATERIAL AVAILABILITY.
COORDINATE ACOUSTICAL SUSPENSION SYSTEM WORK WITH OTHER WORK, SUCH AS CEILING
LIGHT FIXTURES AND AIR OUTLETS. PROTECT FINISHED WORK INSTALLED BEFORE INSTALLATION
OF ACOUSTICAL SUSPENSION SYSTEM. REPLACE WORK DAMAGED BY WORK UNDER THIS
SECTION.
ALL LOCKING CROSS TEES SUPPORTING OTHER CROSS TEES SHALL CONFORM TO THE SAME
CLASSIFICATION AS THE MAIN RUNNERS. MAIN RUNNER S AND CROSS TEES SHALL BE COLD
ROLLED ELECTRO-GALVANIZED STEEL. WALL ANGLE MOLDINGS SHALL BE COLD-ROLLED
ELECTRO-GALVANIZED STEEL. CORNERS SHALL BE MANUFACTURER'S PREFABRICATED INSIDE
AND OUTSIDE CORNER MOLDINGS.
FINISH SHALL BE BAKED ENAMEL IN SELECTED COLOR. REFER TO FINISH SCHEDULE.
HANGER WIRE SHALL BE 12 GAUGE GALVANIZED STEEL WIRE CONFORMING TO FS QQ-W-461,
TYPE I.
INSPECT LOCATIONS TO RECEIVE WORK AND CHECK THE EXISTING DIMENSIONS. ASCERTAIN
BEFORE PROCEEDING WITH WORK THAT ALL REQUIRED INSPECTIONS HAVE BEEN MADE.
COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF RESPONSIBILITY RELATED TO
GUARANTEE REQUIREMENTS. THE BUILDING SHALL BE EXAMINED BEFORE BEGINNING WORK TO
DETERMINE THAT IT IS PROPERLY ENCLOSED AND THE STRUCTURE IS IN PROPER CONDITION TO
RECEIVE ACOUSTICAL MATERIALS. THE AREA SHALL BE BROOM CLEANED AND UNINTERRUPTED
FOR FREE MOVEMENT OF SCAFFOLDING. SCAFFOLDING SHALL BE OF A TYPE THAT WILL NOT
SCAR OR MAR FLOOR SURFACES AND WILL NOT DAMAGE OTHER CONSTRUCTION. WORK NOT TO
PROCEED UNTIL SATISFACTORY CONDITIONS DESCRIBED ABOVE PRESIDE.
ATTACH HANGER WIRE TO SOUND, SECURE STRUCTURAL MEMBERS CAPABLE OF CARRYING THE
NEW LOAD WITHOUT DEFLECTION. WRAP, BOLT OR CLIP WIRE HANGERS TO STRUCTURAL STEEL
MEMBERS, OR INSTALL DROP CLIPS ON STRUCTURAL STEEL MEMBERS AND TIE WIRE HANGERS
TO DROP CLIPS. INSTALL SUPPLEMENTARY FRAMING, BLOCKING AND BRACING WHERE
NECESSARY TO SUSPEND CEILING SYSTEM FIXTURES AND EQUIPMENT AND WHERE SPACING OF
STRUCTURAL SUPPORTS EXCEEDS SPECIFIED HANGER SPACING, WHERE DIRECT SUSPENSION
OF SUPPLEMENTARY FRAMING FOR SUPPORT OF EQUIPMENT, FIXTURE OR DUCTWORK IS NOT
POSSIBLE DUE TO OBSTRUCTIONS, SUPPLEMENTARY FRAMING MAY BE SUSPENDED BY
"TRAPEZE" ARRANGEMENT OF HANGER WIRE. SUSPEND LIGHT FIXTURES FROM STRUCTURE BY
ATTACHMENT OF ONE HANGER AT EACH CORNER OF THE FIXTURE. FURNISH ADDITIONAL WIRES
FOR LIGHTING FIXTURES AND MECHANICAL REGISTERS IN SUSPENDED CEILING. PROVIDE
SEISMIC BRACING AS REQUIRED.
INSTALL CEILING SUSPENSION SYSTEM IN ACCORDANCE WITH ASTM C636. LOADING OF ANY
COMPONENT MAY NOT CAUSE DEFLECTION OF MORE THAN 1/360 OF THE SPAN. USE LASER LIGHT FOR LAYOUT AND LEVELING. INSTALL MAIN RUNNERS 48 INCHES O.C. TIE HANGER WIRES TO MAIN
RUNNERS TIGHTLY WITH AT LEAST THREE FULL TURNS. INTERCONNECT MAIN RUNNERS BY
LOCKING CROSS TEES 48 INCHES LONG TO FORM 24 INCH BY 48 INCH MODULES. WHEREVER
SHOWN ON THE DESIGN PLANS. THESE MODULES SHALL BE DIVIDED BY CROSS TEES TO FORM 24
INCHES LONG INSTALL PERPENDICULAR TO THE OTHER CROSS TEES TO FORM 24 INCH BY 24
INCH SECTIONS. PROPER LENGTH LOCKING CROSS TEES SHALL ALSO BE INSTALLED ADJACENT
TO ALL SIDES OF RECESSED LIGHT FIXTURES NOT SUPPORTED BY A MAIN RUNNER.
ALL SUSPENDED CEILINGS SHALL BE BRACED TO RESIST LATERAL AND HORIZONTAL MOVEMENT
AS SHOWN ON PLANS AND AS REQUIRED BY THE GOVERNING CODES.
CUT TILES TO MATCH FIELD PATTERN RECESS. ANY ACOUSTICAL CEILING PANELS LESS THAN
FULL SIZE SHALL HAVE CUT EDGES TRIMMED TO MATCH FACTORY EDGES. SUSPENDED CEILING
SHALL HAVE INTERSECT ALL VERTICAL WALLS AT 90° UNLESS OTHERWISE NOTED.
UPON COMPLETION OF WORK FOLLOWING INSTALLATION OF SUSPENSION SYSTEMS, DIRTY OR
DISCOLORED SURFACES OF SUSPENSION COMPONENTS SHALL BE CLEANED IN ACCORDANCE
WITH MANUFACTURER'S RECOMMENDATIONS AND LEFT FREE FROM DEFECTS. COMPONENTS
THAT ARE DAMAGED OR IMPROPERLY INSTALLED BE REMOVED AND REPLACED WITHOUT
ADDITIONAL COST TO THE OWNER.
LEAVE TEN (10), FULL, UNDAMAGED TILES AT JOB SITE AS ATTIC STOCK FOR OWNERS USE.
PARTITION WALL -
NON RATED
WALL ABOVE CEILING
NON-LOAD BEARING
STC RATING 44
1 LAYER 5/8" GYP. BD.
EACH SIDE METAL STUD
ACOUSTIC SEALANT
EACH SIDE
METAL STUD RUNNER
SILL
PLAN
HEAD
CEILING AS SCHED.
FLOOR AS SCHED.
LINE OF STRUCTURE
A4 3 5/8" METAL STUDS - 16" O.C. TYP.
GYP BD. EXTENDS TO
DECK
ACOUSTIC SEALANT
EACH SIDE TYP.
FIBERGLASS BATT
INSULATION TO
FILL STUD CAVITY
1/4" DIA. TITEN HD@ 16" O.C.
(2" MIN. EMBEDMENT)
1. REFER TO FLOOR PLAN "A" SERIES FOR LOCATION OF WALL TYPES. ALL
INTERIOR WALLS ARE TYPE "A4" UNLESS NOTED OTHERWISE. ALL EXTERIOR
WALLS ARE EXISTING UNLESS NOTED OTHERWISE.
2. REFER TO SCHEDULES & DETAILS FOR FINISHES. WALL TYPES REFER TO
BASE WALL ONLY.
3. "LINE OF STRUCTURE" AS SHOWN AT THE HEAD CONDITIONS OF EACH
WALL TYPE IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE THE EXACT
CONSTRUCTION CONDITION. RATED WALLS ARE TO TERMINATE AT STRUCTURAL
MEMBERS WITH A FIRE RESISTANT RATING. WHERE REQ'D APPROPRIATE
FRAMING AND GYP BOARD IS TO BE INSTALLED AND OFFSET AROUND
STRUCTURAL MEMBERS OR OTHER OBSTRUCTIONS SUCH AS PIPING OR
DUCTWORK, TO MAINTAIN THE FIRE RESISTANCE RATING. NON-RATED WALLS
THAT CONTINUE TO STRUCTURE ARE TO TERMINATE AT PROPER LOCATIONS TO
MAINTAIN THE INTENT OF THE CONTINUOUS PLANE OF ONE LAYER OF GYP
BOARD AS A NOISE, SMOKE OR OTHER TYPE OF BARRIER.
4. ALL GYP BOARD SHALL BE 5/8", UNLESS NOTED OTHERWISE.
5. ALL RATED WALLS SHALL BE CONSTRUCTED FIRST. SECONDARY WALLS
TO ABUTT, BUT NOT PENETRATION RATED WALLS.
6. APPROPRIATE SUBMITTAL INFORMATION MUST BE PROVIDED TO
SUBSTANTIATE THAT THE MATERIALS AND ASSEMBLY USED BY THE
CONTRACTOR HAVE BEEN TESTED BY A RECOGNIZED TESTING AGENCY TO MEET
THE FIRE RESISTANCE RATING SCHEDULED ON THESE WALL TYPES.
7. FIRESTOPPING TO BE PROVIDED AT PENETRATIONS THROUGH RATED
WALLS AS SPECIFIED.
8. ALL GYPSUM WALL BOARD MUST BE MOISTURE RESISTANT AT THE
FOLLOWING LOCATIONS:
a. TOILET ROOMS
b. WET WALLS
c. JANITOR'S CLOSETS
9. SOUND ATTENUATION BLANKETS SHALL EXTEND THE FULL HEIGHT OF
THE WALLS.
10. SPACING OF THE METAL STUDS HAS NOT BEEN INDICATED ON THE WALL
TYPES OR DETAILS. STUD SPACING IS TO BE DETERMINED BY THE HEIGHT OF
THE PARTITION AS SHOWN IN THE TABLE BELOW. EACH STUD GOING TO
STRUCTURE AND EXCEEDING ALLOWABLE HEIGHTS SHALL BE BRACED 45
DEGREES DIAGONALLY 12" ABOVE CEILING WITH EQUAL SIZE 20 GA. METAL
STUDS. THIS TABLE IS TO BE USED FOR THE INTERIOR WALL TYPES ONLY AND
DOES…
This is the start of the file's text. The full file is on GovTribe.