INDEX OF DRAWINGS
BUCKLEY AFB, COLORADO
BUILDING 1005 JAAB
"Excellence is Our Standard, Customer Service is Our Passion"
BUCKLEY AIR FORCE BASE
COPYRIGHT PROTECTION FOR DRAWINGS
"THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY SETPOINT SYSTEMS CORPORATION FOR
THIS PROJECT ARE INSTRUMENTS OF SETPOINT SYSTEMS CORPORATION'S SERVICE FOR USE SOLELY WITH RESPECT
TO THIS PROJECT, AND UNLESS OTHERWISE PROVIDED, SETPOINT SYSTEMS CORPORATION SHALL BE DEEMED THE
AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT."
Owner: Buckley Air Force Base
Setpoint Systems Corporation's Project Team:
Project Manager: Jon Wilson
Project Applications Engineer: Bob Manthei
Project Account Manager: Andra Keiffer
Lighting Controls
Energy Management
Temperature Controls
CCTV
Access Control
System Integration
IT Services
Fire Alarm
Fire Suppression System
Office Locations:
8167 SouthPark Circle
1360 Reynolds Ave
Littleton, CO 80120
(303) 733-2300
Irvine, CA 92614
(949) 330-0673
California
Rocky Mountain Region
Sheet 1 of 48
Sheet 2 of 48
Sheet 3 of 48
Sheet 0X of 48
Sheet 0XX of 48
Sheet 5 of 48
Sheet 6 of 48
Sheet 7 of 48
Sheet 8 of 48
Sheet 9 of 48
Sheet 10 of 48
Sheet 11 of 48
Sheet 12 of 48
Sheet 13 of 48
Sheet 14 of 48
Sheet 15 of 48
Sheet 16 of 48
Sheet 17 of 48
Sheet 18 of 48
Sheet 19 of 48
Sheet 20 of 48
Sheet 21 of 48
Sheet 22 of 48
Sheet 23 of 48
Sheet 24 of 48
Sheet 25 of 48
Sheet 26 of 48
Sheet 27 of 48
Sheet 28 of 48
Sheet 29 of 48
Sheet 30 of 48
Sheet 31 of 48
Sheet 32 of 48
Sheet 33 of 48
Sheet 34 of 48
Sheet 35 of 48
Sheet 36 of 48
Sheet 37 of 48
Sheet 38 of 48
Sheet 39 of 48
Sheet 40 of 48
Sheet 41 of 48
Sheet 42 of 48
Sheet 43 of 48
Sheet 44 of 48
Sheet 45 of 48
Sheet 46 of 48
Sheet 47 of 48
Sheet 48 of 48
Cover Sheet
Standard Abbreviations
Standard Symbols
BAFB WAN Diagram
BAFB BACnet Devices and Computers
BAFB B1005 System Network Diagram
BAFB B1005 CP63 DEV502100 Detail
BAFB B1005 CP63A Detail
BAFB B1005 HW System Flow Diagram
BAFB B1005 CP502200 Detail
BAFB B1005 CP63C Detail
BAFB B1005 AHU1 Flow Diagram
BAFB B1005 HVAC Shutdown
BAFB B1005 CP502300 Detail
BAFB B1005 CP63D Detail
BAFB B1005 AHU2 Flow Diagram
BAFB B1005 CP2000 Detail
BAFB B1005 CP502000A Detail
BAFB B1005 Lawn Irrigation Flow Diagram
BAFB B1005 CP502301 Detail
BAFB B1005 Chilled Water System Flow Diagram
BAFB B1005 CP502201 Detail
BAFB B1005 Readiness AHU Flow Diagram
BAFB B1005 Readiness AHU Wire Table Page 1
BAFB B1005 CP63H DEV502302 FCU5 Detail
BAFB B1005 CP63I DEV502207 FCU6 Detail
BAFB B1005 FCU5 and FCU6 Flow Diagram
BAFB B1005 CP63E DEV502211 HVU1 Detail
BAFB B1005 CP63F DEV502210 HVU2 Detail
BAFB B1005 CP63G DEV502108 HVU3 Detail
BAFB B1005 HVU1, HVU2, and HVU3 Flow Diagram
BAFB B1005 Power Patch Panel 3 Zone
BAFB B1005 Power Patch Panel 4 Zone
BAFB B1005 Zone Controller Network DEV502100
BAFB B1005 Zone Controller Network DEV502200
BAFB B1005 Zone Controller Network DEV502300
BAFB B1005 Cooling Only VAV
BAFB B1005 Fan Powered VAV with HW Reheat
BAFB B1005 Cooling Only VAV External Actuator
BAFB B1005 FPVAV with HW Reheat External Actuator
BAFB B1005 FPVAV Valve Schedule
BAFB B1005 CRAC#1 & 2 Flow Diagram
BAFB B1005 CP502001-2 Layout
BAFB B1005 CP502001-2 Point Lists
BAFB B1005 CP502001-2 Wiring
BAFB B1005 Generator Monitoring Flow Diagram
BAFB B1005 CP502346 Layout B
AFB B1005 CP502346 Point Lists
BAFB B1005 CP502346 Wiring
F a x
L i t t l e t o n
C o l o r a d o
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R E D
B Y
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
W G
A T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
DRAWING
01 OF
C o v e r
S h e e t d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text Copyright Protection For Drawings
AutoCAD SHX Text "The drawings, specifications, and other documents prepared by Setpoint Systems Corporation for this project are instruments of Setpoint Systems Corporation's service for use solely with respect to this project, and unless otherwise
AutoCAD SHX Text provided, Setpoint Systems Corporation shall be deemed the author of these documents and shall retain all common law, statutory, and other reserved rights, including the copyright."
IDENTIFICATION
SYSTEM POINT/OBJECT
POINT/OBJECT TYPE
DDC SUB-PANEL#
BACNET SOFTWARE POINT/OBJECT ADDRESS
DDC PANEL#
HARDWARE ADDRESS
AI=ANALOG INPUT
POINT/OBJECT ADDRESS
BO=BINARY OUTPUT
BI=BINARY INPUT
AO=ANALOG OUTPUT
POINT/OBJECT TAG
IDENTIFICATION
CONTROL PANEL
POINT/OBJECT NAME/DESCRIPTOR
POINT/OBJECT ADDRESS
POINT/OBJECT STATE/RANGE
ORCA100
AHU1 OA DMP
BAC.0100.AO03
0-10V DC
CONTROL DRAWING POINT/OBJECT TAG
(e)
AC
ACU
AD
AFMS
AHU
AI
ALM
AO
ATD
BI
BLR
BO
BOPD
BOPR
BOTD
BOTR
CAV
CFM
CHLR
CHW
CHWR
CHWS
CO
CO2
COND
CP
CS
CT
CU
CUH
CV
CW
CWR
CWS
D
DA
DM
DPS
DPT
EF
EP
ES
EVC
FACP
FLT
FM
FPB
FS
FT
G
GND
Existing
Air Compressor
Air Conditioning Unit
Air Dryer
Air Flow Monitoring Station
Air Handling Unit
Analog Input
Alarm / Safety Input (suffix)
Analog Output
Auto Tank Drain
Binary Input
Boiler
Binary Output
Break on Pressure Drop
Break on Pressure Rise
Break on Temperature Drop
Break on Temperature Rise
Constant Air Volume
Cubic Ft/Minute volume
Chiller
Chilled Water
Chilled Water Return
Chilled Water Supply
Carbon Monoxide
Carbon Dioxide Sensor
Condenser
Control Panel
Current Switch
Current Transformer
Remote Condensing Unit
Cabinet Unit Heater
Control Valve
Condenser Water
Condenser Water Return
Condenser Water Supply
Damper
Damper Actuator (Pneumatic)
Damper Motor (Electric )
Differential Pressure Switch
Differential Pressure Transmitter
Exhaust Fan
Electric Pneumatic Switch
End Switch
Evaporative Cooling
Fire Alarm Control Panel
Filter
Flow Meter
Fan Powered Box
Flow Switch
Flow Transmitter
Gauge
Ground
Hot (Hot/Line)- voltage
Hand-Off-Auto Switch
Humidity Transmitter
Heating Ventilation Unit
Hot Water
Hot Water Return Temp
Hot Water Supply Temp
Heat Exchanger
Current to Pneumatic Transducer
Indoor Air Quality
Light
Line Filter
Liquid Level Switch
Liquid Level Transmitter
Lighting Control
Low Temperature Switch
Mixed Air
Magnetic Starter
Makeup Air Unit
Motor Control Center
Make on Pressure Drop
Make on Pressure Rise
Make on Temperature Drop
Make on Temperature Rise
Neutral (Line)- voltage
Normally Closed
Normally Open
Outside Air
Overload
Operator Work Station
Pump
Push Button
Pressure Electric Switch
Proximity Switch
Pressure Regulating Valve
Power Supply
Pressure Switch
Relay
Return Air
Receiver Controller
Restrictor
Return Fan
Humidity
Network Repeater
Relief Valve
Supply Air
Smoke Detector
Supply Fan
Surge Protector
Solenoid Valve
Selector Switch
H
HOA
HT
HV
HW
HWR
HWS
HX
I/P
IAQ
L
LF
LLS
LLT
LTG
LTS
MA
MAG
MAU
MCC
MOPD
MOPR
MOTD
MOTR
N
NC
NO
OA
OL
OWS
P
PB
PE
PROX
PRV
PS
PSW
R
RA
RC
RES
RF
RH
RPT
RV
SA
SD
SF
SRG
SV
SW
T
TB
TC
TDR
TF
THT
TP
TR
TRM
TS
TSP
TT
UH
UPS
UV
V
VA
VAC
VAV
VDC
VF
VFD
VSW
W
Thermostat
Terminal Block
Time Clock
Time Delay Relay
Transfer Fan
Temperature Humidity Transmitter
Twisted Pair
Transformer
End of Line Terminator
Temperature Sensor
Twisted Shielded Pair
Temperature Transmitter
Unit Heater
Uninterruptible Power Supply
Unit Ventilator
Valve
Volt/Amps
Volts Alternate Current
Variable Air Volume box
Volts Direct Current
Ventilation Fan
Variable Frequency Drive
Vibration Switch
Thermowell
BAC.0100.AI01
POINT NAMING SCHEMES
16 CHARACTERS MAX ARE STANDARD
LBBFSSS_PPPPP_MM
BUILDING LOCATION
BUILDING NAME/NUMBER
FLOOR NUMBER
SYSTEM TYPE
POINT FUNCTION
POINT FUNCTION MODIFIER
STANDARD ABBREVIATIONS
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
02 OF
S T A N
D A R
B R E V I A T I O
N S d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
AutoCAD SHX Text Copyright Protection For Drawings
AutoCAD SHX Text "The drawings, specifications, and other documents prepared by Setpoint Systems Corporation for this project are instruments of Setpoint Systems Corporation's service for use solely with respect to this project, and unless otherwise provided, Setpoint Systems Corporation shall be deemed the author of these documents and shall retain all common law, statutory, and other reserved rights, including the copyright."
DM
LOW
HIGH
DPT
VFD
MAG
ELECTRIC VALVE (2-WAY)
ELECTRIC VALVE (3-WAY)
PNEUMATIC VALVE (2-WAY)
PNEUMATIC VALVE (3-WAY)
SENSOR (RIGID)
SENSOR (AVERAGING)
DIFFERENTIAL PRESSURE SWITCH (DPS)
VARIABLE FREQUENCY DRIVE
MAGNETIC STARTER
LOW TEMPERATURE SWITCH
ROOM SENSOR
DA
IMMERSION SENSOR W/ WELL
STRAP ON SENSOR
PNEUMATIC DAMPER ACTUATOR WITH POSITIONER
S
M
PNEUMATIC DAMPER ACTUATOR
DA
DM
ELECTRIC DAMPER ACTUATOR
ELECTRIC DAMPER ACTUATOR W/END SWITCH
ES
END SWITCH
ELECTRIC BUTTERFLY VALVE (2-WAY)
ELECTRIC BUTTERFLY VALVE (3-WAY)
PNEUMATIC BUTTERFLY VALVE (2-WAY)
PNEUMATIC BUTTERFLY VALVE (3-WAY)
TERMINATOR
NETWORK REPEATER
SMOKE DETECTOR
SD
PARALLEL BLADE DAMPER
OPPOSED BLADE DAMPER
CURRENT SWITCH/CURRENT TRANSFORMER
RESTRICTOR
NORMALLY OPEN CONTACTS
NORMALLY CLOSED CONTACTS
LOW TEMPERATURE SWITCH
PRESSURE SWITCH
PUSH BUTTON SWITCH
SOLENOID VALVE
PRESSURE REDUCING VALVE
PANEL LIGHT
0 30
10 20
PRESSURE GAUGE
FLOW SWITCH
END SWITCH
TRANSFORMER
MOTOR STARTER OVERLOADS
CURRENT TO PNEUMATIC TRANSDUCER
SECURITY PLATE ROOM TEMPERATURE SENSOR
FS1
GROUND
FLOW SWITCH
ELECTRIC PNEUMATIC VALVE
PRESSURE ELECTRIC SWITCH
HIGH
LOW
DPS
PE-1
I
I/P
D
D
LTS
TS
TS
TS
TS
TS
TS
EP
PE
FS
CS/CT
RES
PRV
DA
DA
DM
DM
ES
V
V
V
V
V
V
V
V
TRM
RPT
DPS
DPT
VFD
MAG
LIGHT
G
SD
TR
NO
NC
OL's
LTS
PS
PB
SV
FS
ES
GND
STANDARD WIRING SYMBOLS
C
C COIL
R RELAYR
P
E
P
FLOW METERFM
DESCRIPTIONABBREVIATION SYMBOL
TRM
RPT
DIFFERENTIAL PRESSURE TRANSMITTER (DPT)
DESCRIPTIONABBREVIATION SYMBOL DESCRIPTIONABBREVIATION SYMBOL
DESCRIPTIONABBREVIATION SYMBOL
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
STANDARD SYMBOLS
S T A N
D A
S
M
B O
L S x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
03 OF
S T A N
D A
M
B O
L S d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
S Y S T
M
N
T W
O R K
D
I A G
R A M
BAFB B1005 SYSTEM NETWORK DIAGRAM
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
10BaseT cable furnished by the Air Force Base
Computer
DEV10032
OWS1
51 2 3 4 76 8
Daisy
Port
Chain
OR
SW1
DFM400P
NET
22/2 TSP MSTP
Computer
DEV10035
OWS3
Located In Telephone
Equipment Room 175
Located in B1006
CP500000
SW1
E C H
E L O
N
C A
L O
T
PC/104 E-NET EXPANSION CARD
A D
D I T I O
N A L
M
E M
O R Y
S L O
T
P a n e l
A d d r e s s
O F F
O N
DEV500000
G N
D
~ COM 1 COM 2
RS-485
P O
W E R
S C A N
E T H
E R N
E T
L N
K
A C T
X
X
X
X
X
X
X
X
X
RX
TX
DSM-050
22/2 TSP MSTP
DEV500001
DEV500002
Located In Mechanical
Room 120
CP502000
E C H
E L O
N
C A
O
T
PC/104 E-NET EXPANSION CARD
A D
D I T I O
N A L
M
E M
O R Y
S L O
T
P a n e l
A d d r e s s
O F F
O N
DEV502000
G N
D
COM 1 COM 2
RS-485
P O
W E R
S C A N
E T H
E R N
E T
L N
K
A C T
X
X
X
X
X
X
X
X
X
RX
TX
DCU-050
Lawn Sprinkler
System
51 2 3 4 76 8
Daisy
Port
Chain
OR
SW2
SW2
10BaseT CAT5
10BaseT CAT5
10BaseT CAT5
10BaseT CAT5
10BaseT CAT5
10BaseT CAT5
10BaseT CAT5
Located In Mechanical
Room 170
CP502300
AHU2
10BaseT CAT5
V3.33
V3.33
Located In Mechanical
Room 170
CP502301
Chilled Water
System
DEV502300
DSC1280
V3.33
DEV502301
DAC1146
V3.33
T
PP23A
RS485
22TSP
RS485 #3
24vac #3
To All Loop #3 Controllers refer
To Zone Controller network
22TSP
14TP
Detail Sheet
RS485
From PP4A
RS485 #6
24vac #6
PP23B
To All Loop #6 Controllers refer
To Zone Controller network Detail Sheet
RS485 #5
24vac #5
To All Loop #5 Controllers refer
To Zone Controller network Detail Sheet
T
22TSP
22TSP
14TP
14TP
RS485 #2
24vac #2
To All Loop #2 Controllers refer
To Zone Controller network
22TSP
14TP
Detail Sheet
Electric Meter
RS485 #1
24vac #1
To All Loop #1 Controllers refer
To Zone Controller network
22TSP
14TP
Detail Sheet
RS485 #4
24vac #4
To All Loop #4 Controllers refer
To Zone Controller network Detail Sheet
22TSP
14TP
Located In Mechanical
Room 120
CP63
E C H
E L O
N
C A
O
T
PC/104 E-NET EXPANSION CARD
A D
D I T I O
N A L
M
E M
O R Y
S L O
T
P a n e l
A d d r e s s
O F F
O N
DEV502100
G N
D
~ COM 1 COM 2
RS-485
P O
W E R
S C A
NE
T H
E R N
E T
L N
K
A C T
X
X
X
X
X
X
X
X
X
RX
TX
DCU-050
Hot Water
System
51 2 3 4
SW3
SW3
10BaseT CAT5
Located In Mechanical
Room 120
CP502200
AHU1
10BaseT CAT5
V3.33
DEV502200
DSC1280
V3.33
T
PP21A
RS485
22TSP
RS485 #4
24vac #4
To All Loop #4 Controllers refer
To Zone Controller network
22TSP
14TP
Detail Sheet
Located in Mechanical RM120
RS485 #3
24vac #3
To All Loop #3 Controllers refer
To Zone Controller network
22TSP
14TP
Detail Sheet
RS485 #2
24vac #2
To All Loop #2 Controllers refer
To Zone Controller network
22TSP
14TP
Detail Sheet
Level 2
Level 1
Level 2
Level 1
RS485
From PP4A
RS485 #7
24vac #7
PP21B
To All Loop #7 Controllers refer
To Zone Controller network Detail Sheet
RS485 #6
24vac #6
To All Loop #6 Controllers refer
To Zone Controller network Detail Sheet
T
22TSP
22TSP
14TP
14TP
RS485 #5
24vac #5
To All Loop #5 Controllers refer
To Zone Controller network Detail Sheet
22TSP
14TP
RS485 #1
24vac #1
To All Loop #1 Controllers refer
To Zone Controller network
22TSP
14TP
RS485
22TSP
10BaseT CAT510BaseT CAT5
Located above ceiling in Interstitial Space
CP502201
AHU
DEV502201
DSC1280
V3.33
Readiness Area
T
RS485 #1
24vac #1
22TSP
14TP
Located in Mechanical RM170
To all Loop #1 controllers.
Refer to Zone Controller
Network.
Located In Rm 179
CP502001/2
CRAC#1
DEV502344
DAC606
V3.33
CRAC#2
DEV502345
DAC606
V3.33
VERIS
DEV502344-1
DFM400
V3.33
Located In Mechanical
Room 170
CP502346
Generator
Monitoring
DEV502346
DAC606
V3.33
RS485
22TSP
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
05 OF
B A F B
B
S y s t e m
N t w o r k
D i a g r a m d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
C O
N T R O
L
P A N
E L
C P
D
E V
D
E T A I L
BAFB B1005 CONTROL PANEL CP63 DEV502100 DETAIL
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
BAC.502100.AI01
JAAB HWS TEMP
BAC.502100.AI02
JAAB HWR TEMP
BAC.502100.BI03
JAAB HWP1 FLW SW
BAC.502100.BI04
JAAB HWP2 FLW SW
BAC.502100.BI05
JAAB BLR EPO
BAC.502100.BI06
JAAB BLR1 ALM
BAC.502100.BI07
JAAB BLR2 ALM
BAC.502100.BI08
JAAB BLR3 ALM
BAC.502100.BI09
JAAB BLR WTR FLR
BAC.502100.BI10
JAAB HWS GLYCL FDR ST
BAC.502100.BI11
JAAB HWS GLYCL FDR ALM
BAC.502100.XI12
BAC.502100.XI13
BAC.502100.XI14
BAC.502100.XI15
BAC.502100.XI16
BAC.502100.XI17
BAC.502100.XI18
BAC.502100.XI19
BAC.502100.XI20
BAC.502100.XI21
BAC.502100.XI22
BAC.502100.XI23
BAC.502100.XI24
BAC.502100.XI25
BAC.502100.XI26
BAC.502100.XI27
BAC.502100.XI28
BAC.502100.XI29
BAC.502100.XI30
BAC.502100.XI31
BAC.502100.XI32
BAC.502100.BO01
BAC.502100.XO02
BAC.502100.XO03
JAAB HWP1 SS
BAC.502100.BO04
JAAB HWP2 SS
BAC.502100.AO05
JAAB BYPASS VLV
BAC.502100.BO06
JAAB HWS GLYCL FDR ENA
BAC.502100.XO07
BAC.502100.XO08
BAC.502100.X009
BAC.502100.XO10
BAC.502100.XO11
BAC.502100.XO12
BAC.502100.XO13
BAC.502100.XO14
BAC.502100.XO15
BAC.502100.AO16
JAAB BLR RESET
ORCA-502100
GND
INPUT JUMPER
INPUT JUMPER
m
A
ORCA
18TP
V
V
DIGITAL INPUT
10K OHM THERMISTOR
TEMPERATURE SENSOR
18TP
ORCA
m
A
V
V
J U
M P E R
K
O
H M
DETAIL 2
DETAIL 2
DETAIL 2
DETAIL 2
DETAIL 2
DETAIL 2
K
O
H M
DETAIL 1
DETAIL 1
DETAIL 1
J U
M P E R
MODULAR RELAY
RELAY
15AMP
120V
DETAIL 4
DETAIL 5
DETAIL 4
ORCA
AC/DC
COM
10-30V
STATUS
LED
NO
DETAIL 4
COM
NC
Black background.
CP63
20 inches i n c h e s
White letters on
General Notes:
ORCA502100 is being upgraded to Version 3.30.
PANEL ADDRESS
X
32 X
X
X
X
O F F
X
O N
X
X
X
X
BASE INPUT OUTPUT BOARD
SYMBOL
ORCA-2100
QTY
MANUFACTURER
BILL OF MATERIAL
DESCRIPTION
PART #
DBB060
DELTA
ORCA ENCLOSURE W/ MOUNTING RAILS AND BACKPLANE
CUSTOM
SETPOINT SYSTEMS
VALVE ACTUATOR
Y1 Input,2-10V
+ Hot
Common
18TP
ORCA
X2
24VAC
X1
DETAIL 5
MOUNT@ STARTER
RELAY IN A BOX
WHT/BLU
ORCA
WHT/YLW
RIBU1C
DETAIL 6
ORNG
YLW
INPUT JUMPERCURRENT SWITCH
SWITCH
CURRENT
OUT
COM
m
A
V
V
18TP
ORCA
K
O
H M
DETAIL 3
J U
M P E R
DETAIL 3
DETAIL 2
DETAIL 6
DETAIL 6
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
06 OF
B A F B
B
C o n t r o l
P a n e l
C P
D
E V
D e t a i l d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
C O
N T R O
L
P A N
E L
C P A
D
E T A I L
BAFB B1005 CONTROL PANEL CP63A DETAIL
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
TB1
CB1
L
TB2
N
N
X1
X1
X1
X2
L
X2
CONTROL PANEL CP63A. Located in Mechanical Room120 Near ORCA 2100.
100VA
XFMR1
X2
X1
24VAC
FILTER1GND
VAC
L
BROWN
GREEN
BLUE
N
L
N
G
X2
X1
XFMR2
50VA
24VAC
120VAC
TB2
TB2
X2
X1
H
N
TB2
TB2
120VAC
N
H TB2
TB2
X2
POWER
LINE FILTER, 120VAC
BILL OF MATERIAL
CB1
SYMBOL
CIRCUIT BREAKER, 2AMP1
QTY
DESCRIPTION
440100
S271-K2
PART # MANUFACTURER
ABB
DELTA
FILTER1
TERMINAL BLOCK, 3-SLOT
TRANSFORMER, 120VAC TO 24VAC, 100VA
TB1,2
XFMR1
NDN3
691-K1
CONNECTRON
KELE & ASSOCIATES
CP63A 1 18X12X7 CONTROL PANEL, NEMA-1
RET 2018
KELE
DELTA
MECHANICAL RELAY WITH BASE, 10VDC COIL
R1-4
430200/430201
HOT WATER RETURN TEMPERATURE SENSOR
10K OHM THERMISTOR
COM
A2
R1
NO
BLR1 ENABLE RELAY
A1
NC
X2
TB2
TB2
HWP-1 FLOW SWITCH STATUS
X1
R-1A
R-1B
R-1C
TB2
TB2
TB2
TB2
TB1 1
2TB1
18TP
JAAB_BLR1_ENA
BAC.2100.BO01
TO ORCA-2100
24VAC POWER
18TP
TB1
TB1
BAC.2100.BO02
JAAB_BLR2_ENA
18TP
BAC.2100.BO04
JAAB_HWP2_SS
BAC.2100.BO03
JAAB_HWP1_SS
18TP
18TP
TB1
TB1
TB1
TB1
TB1
TB1
TB1
TB1
BAC.2100.AO05
JAAB_BYPASS_VLV
18TP
TB1
TB1
TB1
TB1
TB1
TB1
R1
A2
A1
COM
NO
NC
X2
BLR2 ENABLE RELAY
TB2
TB2
HWP1 S/S RELAY
A1
TB1
TB1 8
R1
A2
NO
COM
X2
NC
TB2
TB2
X2
COM
TB1 10
R1
A2
NO
HWP2 S/S RELAY
TB1
A1
NC
TB2
TB2
STARTER
TO HWP1
TB2
R-1D
STARTER
TO HWP2
PANEL
TO BOILER-1
PANEL
TO BOILER-2
TRANSFORMER, 120VAC TO 24VAC, 50VA
XFMR2
DELTA
440003
JAAB_HWR_TEMP
BAC.2100.AI02
HOT WATER SUPPLY TEMPERATURE SENSOR
10K OHM THERMISTOR
BAC.2100.AI01
JAAB_HWS_TEMP
JAAB_HWP1_FLW_SW
BAC.2100.BI03
JAAB_HWP2_FLW_SW
HWP-2 FLOW SWITCH STATUS
BAC.2100.BI04
JAAB_BLR1_ALM
BOILER-1 ALARM
BAC.2100.BI06
BOILER-2 ALARM
BAC.2100.BI08
JAAB_BLR2_ALM
HW VALVE
TB2
TB2 3
TB2
TB2
X2
X1
TB2
TB2
Black background.
CP63
20 inches i n c h e s
White letters on
Black background.
CP63A
18 inches i n c h e s
White letters on
ORCA 2100
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
07 OF
B A F B
B
C P A
D e t a i l d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
H
O T
W
A T E R
S Y S T
O
W
D
I A G
R A M
BAFB B1005 HOT WATER SYSTEM FLOW DIAGRAM
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
(n)
N.O.
COM
WD100
DEV502100
JAAB HWR TEMP
BAC.502100.AI02
-58°F - 302°F
DEV502100
JAAB BYPASS VLV
BAC.502100.AO05
0-10VDC
DEV502100
JAAB HWS TEMP
BAC.502100.AI01
-58°F - 302°F
DEV502100
JAAB HWP1 SS
BAC.502100.BO03
DA = ON
DEV502100
JAAB HWP1 ST
BAC.502100.BI03
DA = ON
DEV502100
JAAB HWP2 SS
BAC.502100.BO04
DA = ON
DEV502100
JAAB HWP2 ST
BAC.502100.BI04
DA = ON
DEV502100
JAAB BLR2 ALM
BAC.502100.BI07
DA = ON
DEV502100
JAAB BLR1 ALM
BAC.502100.BI06
DA = ON
DEV502100
JAAB BLR WTR FLR
BAC.502100.BI09
DA = ON
Water Detection
DEV502100
JAAB HWS GLYCL FDR ALM
BAC.502100.BI11
DA = Alarm
DEV502100
JAAB HWS GLYCL FDR ENA
BAC.502100.BO06
DA = ON
DEV502100
JAAB HWS GLYCL FDR ST
BAC.502100.BI10
DA = ON
CONTROL
PANEL
BOILER#1
R
RIB-10A
R
RIB-10A
CONTROL
PANEL
BOILER#2
R
RIB-10A
R
RIB-10A
CONTROL
PANEL
BOILER#3
R
RIB-10A
R
RIB-10A
HWP-1
MAG
DEV502100
JAAB BLR3 ALM
BAC.502100.BI08
DA = ON
HWP-2
MAG
MASTER SLAVE SLAVE
F S
F S
TS
TS
TS
EPO
EPO
EPO
SW
Emergency
DEV502100
JAAB BLR EPO1
BAC.502100.BI05
D.A. = ALARM
GL-A
CB-O
SW-O
Power Off
DEV502100
JAAB_BLR RESET
BAC.502100.AO16
DA = ON
Heating Water System
When the OA Temp is < 60°F (adj.) the DDC enables the lead HW pump to run continuously. The
DDC monitors pump run status via flow switch and should the pump fail while commanded on the
DDC starts the lag pump and generates an alarm at the OWS.
The boilers are provided with factory operating and safety control packages to maintain the desired leaving water temperature to the system.
The bypass valve modulates to maintain the system HWS temperature based on the following schedule.
OA Temp HWS Temp
20°F 180°F
60°F 120°F
Emergency Power Off Switches:
Upon activation, the EPO switches located at the entries to the boiler mech room, will disable the boilers and generate an alarm at the OWS.
BILL OF MATERIALS
ID#
QUANTITY
TAG PART DESCRIPTION TYPE
27320 1 CB-O PILNOCB Normally Open Contact Block
FIELD
27321 1 GL-A PILSTDSGLS
2 Extra Glass Inserts Field
30765 6 RIB-10A RIBU1C Enclosed 10A SPDT Relay 10VDC Field
28119 1 SW-O ST120SN1-BS Break Glass - To Release Button-Boiler Shutdown Field
RS485
RS485
18/2 x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
08 OF
B A F B
B
H
W
S y s t l w i a g r a m d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
C P
D
E T A I L
BAFB B1005 CP502200 DETAIL
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
BILL OF MATERIALS
PANEL#
120VAC POWER
CIRCUIT#
N
TB2
H i n c h e s
CP502200A
12 inches
White letters on black background
Version 3.30
PANEL ADDRESS
X
X
X
X
X
X
X
X
X
X
O F F
O N
E T H
E R N
E T
DSC-1280
IP3
IP11
GND
IP12
GND
IP9
GND
IP10
GND
IP7
GND
GND
IP8
IP5
IP6
GND
GND
GND
IP4
INPUTS
24VAC
PWR IN
IP1
GND
IP2
GND
GND
MS/TP
LAN PORT
GND
P6
P1
24~
PWR
INPUTS
2 AMP
F1
OP3
OUTPUTS
GND
OP8
GND
OP7
GND
OP6
OP5
GND
GND
OP4
OUTPUTS
OP1
GND
GND
OP2
GND
GND
DTR
DCD
Rx
Tx
R S
P8
24VAC PWR
OUT
PORT
SUBLAN
P7
GND
PWR
24~
CP502200
BAC.502200.XI01
BAC.502200.AI02
JAAB AH1 DA TP
BAC.502200.AI03
JAAB AH1 MA TP
BAC.502200.AI04
JAAB AH1 RA TP
BAC.502200.AI05
JAAB AH1 SP
BAC.502200.BI06
JAAB AH1 SF ST
BAC.502200.AI07
JAAB AH1 FLTR ST
BAC.502200.BI08
JAAB AH1 FREEZE
BAC.502200.BI09
AHU1 WTR FLR
BAC.502200.XI10
BAC.502200.BI11
B1005_HVAC_RESET
BAC.502200.BI12
B1005_HVAC_SHUTDWN
BAC.502200.BO01
JAAB AH1 SF SS
BAC.502200.AO02
JAAB AH1 ECONO MIN
BAC.502200.AO03
JAAB AH1 HWC VLV
BAC.502200.AO04
JAAB AH1 CWC VLV
BAC.502200.AO05
JAAB AH1 SF VFD SPD
BAC.502200.BO06
JAAB EF1 SS
BAC.502200.XO07
B1005 AH1 ECONO MAX
BAC.502200.BO08
B1005_HVAC_STROBE
100VA
TR1
24VAC
TX1
COM ~
H
N
VAC
TB2
G
Chain
Port
Daisy
532 41 86 7
OR
ENET Switch
120VAC
T o
P a n e l l
C P
T o
E N
E T o c a t e d i n
T e l
R m x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
09 OF
B A F B
B
C P
D e t a i l d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
C P C
D
E T A I L
BAFB B1005 CP63C DETAIL
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
TB1
CB1
L
TB2
N
N
X1
X1
X1
X2
L
X2
CONTROL PANEL CP63C is Located in Mechanical Room 120
X2
X1
XFMR2
50VA
24VAC
120VAC
TB2
TB2
X2
X1
H
N
TB2
TB2
120VAC
COM
OP1
X2
POWER
DISCHARGE AIR SENSOR FOR AHU1
10K OHM THERMISTER
TB1
TB1
RETURN AIR SENSOR FOR AHU1
10K OHM THERMISTER
MIXED AIR SENSOR FOR AHU1
10K OHM THERMISTER
TB1
TB1
TB1
TB1
DUCT STATIC PRESSURE
TRANSMITTER FOR AHU1
10 TB1
TB1
SIGNAL
4-20mA
N.C
C
N.O.
TB1 9
TB1
TB1
SWITCH FOR AHU1
FILTER DIFFERENTIAL PRESSURE
SWITCH FOR AHU1 S.F. STATUS
S.F. DIFFERENTIAL PRESSURE
N.O.
N.C
C
TB1
TB1
COM
A2
R1
NO
AHU1 SF S/S RELAY
A1
NC
DA-1A
AIR HANDLING UNIT #1 FIELD WIRING
A
OFF
H
C
OL'S
AHU1 STARTER
120 VAC
FUSE*
TB9 TB9
CNC
C NO
AHU1 TEMP.
LOW LIMIT (TLL1)
X2
X1
TB2
TB2
R-1B
TB1
TB1
R-1A
A
B
SMK-1
SMK-2
24 VAC
TB2
TB2
TRANSFORMER
TB2
TB2
X2
A2
R2
NO
EF-1 SF S/S RELAY
OP6
COM
NC
COM
A1
TB2
TB2
TB2
TB2
CONTROL POWER PANEL
(MOUNTED ON FAN MODULE)
MA DAMPER
TB2
TB2
HW VALVE
TB2
TB2
X2
X1
TB2
TB2
TB2
TB2
CHW VALVE
DA-1B
SF VANE
CONTROL POWER PANEL
(MOUNTED ON FAN MODULE)
TB9TB9
TB2
TB2
TB2
A
R-1C
TB2
B
TO EF-1
DAMPER
AIR HANDLING UNIT #1
AIR HANDLING UNIT #1
SWITCH FOR AHU1
FLOOR WATER DETECTOR
N.O.
19 TB1
TB1
WD100
COM
X2 X1
NOTE: REUSE ALL EXISTING POINTS AND TERMINAL BLOCKS, WIRE FROM TB1 AND TB2 TO NEW DSC IN
CP502200.
JAAB EF1 SS
BAC.502200.BO06
JAAB AHU1 SF SS
BAC.502200.BO01
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
10 OF
B A F B
B
C P A
D e t a i l d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text
120VAC
AutoCAD SHX Text
3 AMP
AutoCAD SHX Text
F B
B
A H
U
F L O
W
D
I A G
R A M
BAFB B1005 AHU1 FLOW DIAGRAM
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
OA
RA
FILTER
H
C
C
C
SA
N.C.
NO
COM
NC
CHWS
CHWR
Manual Reset
37.5 degF
PDT1
HIGH LOW
Reference to the space.
Located in the supply duct
2/3rds the length of the longest duct run.
24VAC
CP63C
N.O.
DPS2
HIGH LOW
PDS3
Low High
24VAC
24VAC
SEQUENCE OF OPERATION FOR AIR HANDLING UNIT (AHU-1 & AHU-2)
OCCUPIED CYCLE:
Unit fan shall run continuously. Outside and return air dampers shall modulate to maintain 55 degF (adj.)
discharge air temperature. A mixed air low limit shall be provided to keep the mixed air from falling below 45 degF (adj.). Above 55 degF discharge air temperature, the outside air damper shall open to its minimum position.
During occupied operation, the supply fan VFD modulate to maintain 1.0" w.c. (adj.) duct static at
2/3 distance down the longest duct run. When the outside air damper is at minimum position, the heating coil valve will modulate to maintain 55 degF (adj.) discharge air temperature. When the outside air can no longer satisfy the discharge air setpoint and has returned to minimum position, the cooling coil valve will modulate as required to maintain discharge air setpoint. The discharge air setpoint is reset to maximum temperature which satisfies the warmest zone.
UNOCCUPIED CYCLE:
Unit fan shall be off with outside air damper closed, supply fan VFD closed, heating coil valve open to the coil and cooling coil valve open to coil.
WARM UP CYCLE:
Warm up cycle uses optimal start programming to determine when would be the best time to begin warm
up. The outside air dampers remain closed, the heating coil modulates to maintain 75 degF return air temperature. VFD modulate as required to maintain duct static pressure setpoint. The unit operates in this mode until all zones have reached minimum heating setpoint.
SAFETIES:
Duct mounted supply and return duct detectors which shut fan off, close the outside air dampers and VFD.
The unit is also provided with a heating coil discharge air low limit sensor which stops the unit, closes the outside air dampers and opens the heating coil valve to full flow through the coil whenever the low limit is tripped.
HWS
HWR
NC
COM
NO
T1 T2
GREYSTONE WATER DETECTOR
COM
N.O.
WD100
+ (n)
24VAC
CP63C
DEV502200
JAAB AH1 FAN SS
BAC.502200.BO01
= ON
DEV502200
JAAB AH1 FAN ST
BAC.502200.BI06
= ON
DEV502200
JAAB AH1 FLTR ST
BAC.502200.BI07
= CLEAN
DEV502200
JAAB AH1 FREEZE
BAC.502200.BI08
= OFF
DEV502200
JAAB AH1 RA TP
BAC.502200.AI04
-58 - 302°F
DEV502200
JAAB AH1 ECONO MIN
BAC.502200.AO02
0-10VDC
DEV502200
JAAB AH1 HWC VLV
BAC.502200.AO03
0-10VDC
DEV502200
JAAB AH1 AM TP
BAC.502200.AI03
-58 - 302°F
DEV502200
JAAB AH1 SF VFD SPD
BAC.502200.AO05
0-10VDC
DEV502200
JAAB AH1 DA TP
BAC.502200.AI02
-58 - 302°F
DEV502200
JAAB AH1 CWC VLV
BAC.502200.AO04
0-10VDC
DEV502200
JAAB AH1 DA SP
BAC.502200.AI05
0-3" W.C.
DEV502200
AHU1 WTR FLR
BAC.502200.BI09
= OFF
VFD
V2V1
QTY
T1,2
SYMBOL
DUCT AVERAGING TEMP. SENSOR, 24' COPPER
MANUFACTURER
DESCRIPTION PART #
400152
DELTA
BILL OF MATERIAL
FLOOR WATER DETECTION SWITCH
WD100
WD-100
GREYSTONE
DEV502200
JAAB AH1 ECONO MAX
BAC.502200.AO07
0-10VDC
BILL OF MATERIALS
ID#
QUANTITY
TAG PART DESCRIPTION TYPE
63199 3 ACT-5 AF24-MFT US 133 IN LB 24VAC MFT. ACT. SPR RET FIELD
2 REQ'D
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
11 OF
B A F B
B
A H
U
F l a g r a m d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
AutoCAD SHX Text
ACT-5
AutoCAD SHX Text
ACT-5
ACT-5
F B
B
H
V A C
S H
U T D
O W
N
BAFB B1005 HVAC SHUTDOWN
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
EMERGENCY HVAC SHUT-DOWN
Shuts down all central HVAC Air Handling Equipment
Lift-Cover Switch
(Boilers and Chillers will be unaffected)
DEV502200
B1005 HVAC STROBE 2
BAC.502200.BO08
D.A. = ON
Location: 1st Flr SW Corridor
EMERGENCY HVAC SHUT-DOWN
Shuts down all central HVAC Air Handling Equipment
Lift-Cover Switch
(Boilers and Chillers will be unaffected)
Location: Below Strobe
EMERGENCY HVAC SHUT-DOWN RESET
Resets all central HVAC Air Handling Equipment
Pushbutton Mounted on Panel Cover
(Boilers and Chillers will be unaffected)
DEV502200
B1005 HVAC RESET
BAC.502200.BI11
D.A. = ON
HVAC RESET
EMERGENCY HVAC SHUT-DOWN
Shuts down all central HVAC Air Handling Equipment
Lift-Cover Switch
(Boilers and Chillers will be unaffected)
DEV502200
B1005 HVAC SHUTDN 2
BAC.502200.BI12
D.A. = ON
Location: Below Strobe
HVAC SHUT-DOWN
89STR-A-AQ
Strobe Light
GND
HVAC Shut Down Push Button
INP
HVAC Shut Down Push Button
GND
Reset Push Button
INP
Location: on Control Panel CP30200
10-30V
AC/DC
120V
COM
15AMP
RELAY
STATUS LED
COM
NO
NC
GND
OP
A
X1 X2
24Vac From
Existing Xfmr at DDC Panel
Relay mounted at DDC Panel
EMERGENCY HVAC SHUT-DOWN
Shuts down all central HVAC Air Handling Equipment
Lift-Cover Switch
(Boilers and Chillers will be unaffected)
Location: 2nd Flr SW Corridor
89STR-A-AQ
Strobe Light
A
Mount Push Button at wall 44" A.F.F. Mount Push Button at wall 44" A.F.F.
Mount Strobe Light at wall 84" A.F.F.Mount Strobe Light at wall 84" A.F.F.
General Instructions:
Mount Strobe and Push Buttons Together, with the Push Button directly below the Strobe Light unless indicated otherwise. Insure that Strobe
Light is visable for greatest area of coverage.
1.
Wire multiple push buttons reporting back to a single DDC Input Point in parallel.
2.
Mount Reset Push Buttons on DDC Control Panel front cover; Flush mount push button to cover.
3.
EMERGENCY
WPS-RP1-HS
Flush Mount
Momentary PB w/Raise Cover
WPS-MO-HVAC RESET
Flush Mount
Momentary PB w/PILNOCB Contact Block
& PILNOCB Contact Block
WPS-RP1-HS
Flush Mount
Momentary PB w/Raise Cover
& PILNOCB Contact Block
HVAC SHUT-DOWN
EMERGENCY
PB1 PB2
STR-2STR-1
PB3
R1
Location: Mechanical Rm.
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
12 OF
B A F B
B
H
V A C
S h u t d o w n d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
C P
D
E T A I L
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
BAFB B1005 CP502300 DETAIL
BILL OF MATERIALS
PANEL#
120VAC POWER
CIRCUIT#
N
TB2
H i n c h e s
CP502300A
12 inches
White letters on black background
Version 3.30
PANEL ADDRESS
X
X
X
X
X
X
X
X
X
X
O F F
O N
E T H
E R N
E T
DSC-1280
IP3
IP11
GND
IP12
GND
IP9
GND
IP10
GND
IP7
GND
GND
IP8
IP5
IP6
GND
GND
GND
IP4
INPUTS
24VAC
PWR IN
IP1
GND
IP2
GND
GND
MS/TP
LAN PORT
GND
P6
P1
24~
PWR
INPUTS
2 AMP
F1
OP3
OUTPUTS
GND
OP8
GND
OP7
GND
OP6
OP5
GND
GND
OP4
OUTPUTS
OP1
GND
GND
OP2
GND
GND
DTR
DCD
Rx
Tx
R S
P8
24VAC PWR
OUT
PORT
SUBLAN
P7
GND
PWR
24~
CP502300
BAC.502300.XI01
JAAB_OA_TEMP
BAC.502300.AI02
JAAB AH2 DA TP
BAC.502300.AI03
JAAB AH2 MA TP
BAC.502300.AI04
JAAB AH2 RA TP
BAC.502300.AI05
JAAB AH2 SP
BAC.502300.BI06
JAAB AH2 SF ST
BAC.502300.AI07
JAAB AH2 FLTR ST
BAC.502300.BI08
JAAB AH2 FREEZE
BAC.502300.BI09
AHU1 WTR FLR
BAC.502300.XI10
BAC.502300.XI11
BAC.502300.XI12
BAC.502300.BO01
JAAB AH2 SF SS
BAC.502300.AO02
JAAB AH2 ECONO MIN
BAC.502300.AO03
JAAB AH2 HWC VLV
BAC.502300.AO04
JAAB AH2 CWC VLV
BAC.502300.AO05
JAAB AH2 SF VFD SPD
BAC.502300.BO06
JAAB EF2 SS
BAC.502300.XO07
JAAB AH2 ECONO MAX
BAC.502300.XO08
100VA
TR1
24VAC
TX1
COM ~
H
N
VAC
TB2
G
T o
S W i n
T e l e p h o n e
R o o m x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
13 OF
B A F B
B
C P
D e t a i l d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
F B
B
C P
T A I L
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
BAFB B1005 CP63D DETAIL
TB1
CB1
L
TB2
N
N
X1
X1
X1
X2
L
X2
CONTROL PANEL CP63D is Located in Mechanical Room 170
X2
X1
XFMR2
50VA
24VAC
120VAC
TB2
TB2
X2
X1
H
N
TB2
TB2
120VAC
COM
OP1
X2
POWER
DISCHARGE AIR SENSOR FOR AHU2
10K OHM THERMISTER
TB1
TB1
RETURN AIR SENSOR FOR AHU2
10K OHM THERMISTER
MIXED AIR SENSOR FOR AHU2
10K OHM THERMISTER
TB1
TB1
TB1
TB1
DUCT STATIC PRESSURE
TRANSMITTER FOR AHU2
10 TB1
TB1
SIGNAL
4-20mA
N.C
C
N.O.
TB1 9
TB1
TB1
SWITCH FOR AHU2
FILTER DIFFERENTIAL PRESSURE
SWITCH FOR AHU2 S.F. STATUS
S.F. DIFFERENTIAL PRESSURE
N.O.
N.C
C
TB1
TB1
COM
A2
R1
NO
AHU2 SF S/S RELAY
A1
NC
DA-1A
AIR HANDLING UNIT #2 FIELD WIRING
A
OFF
H
C
OL'S
AHU2 STARTER
120 VAC
FUSE*
TB9 TB9
CNC
C NO
AHU2 TEMP.
LOW LIMIT (TLL1)
X2
X1
TB2
TB2
R-1B
TB1
TB1
R-1A
A
B
SMK-1
SMK-2
24 VAC
TB2
TB2
TRANSFORMER
TB2
TB2
X2
A2
R2
NO
EF-2 SF S/S RELAY
OP6
COM
NC
COM
A1
TB2
TB2
TB2
TB2
CONTROL POWER PANEL
(MOUNTED ON FAN MODULE)
MA DAMPER
TB2
TB2
HW VALVE
TB2
TB2
X2
X1
TB2
TB2
TB2
TB2
CHW VALVE
DA-1B
SF VANE
CONTROL POWER PANEL
(MOUNTED ON FAN MODULE)
TB9TB9
TB2
TB2
TB2
A
R-1C
TB2
B
TO EF-2
DAMPER
AIR HANDLING UNIT #12
SWITCH FOR AHU2
FLOOR WATER DETECTOR
N.O.
19 TB1
TB1
WD100
COM
X2 X1
NOTE: REUSE ALL EXISTING POINTS AND TERMINAL BLOCKS, WIRE FROM TB1 AND TB2 TO NEW DSC IN
CP502300.
JAAB EF2 SS
BAC.502300.BO06
JAAB AHU2 SF SS
BAC.502300.BO01
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
14 OF
B A F B
B
C P t a i l d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
AutoCAD SHX Text L
AutoCAD SHX Text N
AutoCAD SHX Text
120VAC
AutoCAD SHX Text
3 AMP
AutoCAD SHX Text
F B
B
A H
U
F L O
W
D
I A G
R A M
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
BAFB B1005 AHU2 FLOW DIAGRAM
OA
RA
FILTER
H
C
C
C
SA
N.C.
NO
COM
NC
CHWS
CHWR
Manual Reset
37.5 degF
PDT1
HIGH LOW
Reference to the space.
Located in the supply duct
2/3rds the length of the longest duct run.
24VAC
CP63D
N.O.
DPS2
HIGH LOW
PDS3
Low High
24VAC
24VAC
SEQUENCE OF OPERATION FOR AIR HANDLING UNIT (AHU-1 & AHU-2)
OCCUPIED CYCLE:
Unit fan shall run continuously. Outside and return air dampers shall modulate to maintain 55 degF (adj.)
discharge air temperature. A mixed air low limit shall be provided to keep the mixed air from falling below 45 degF (adj.). Above 55 degF discharge air temperature, the outside air damper shall open to its minimum position.
During occupied operation, the supply fan VFD modulate to maintain 1.0" w.c. (adj.) duct static at
2/3 distance down the longest duct run. When the outside air damper is at minimum position, the heating coil valve will modulate to maintain 55 degF (adj.) discharge air temperature. When the outside air can no longer satisfy the discharge air setpoint and has returned to minimum position, the cooling coil valve will modulate as required to maintain discharge air setpoint. The discharge air setpoint is reset to maximum temperature which satisfies the warmest zone.
UNOCCUPIED CYCLE:
Unit fan shall be off with outside air damper closed, supply fan VFD closed, heating coil valve open to the coil and cooling coil valve open to coil.
WARM UP CYCLE:
Warm up cycle uses optimal start programming to determine when would be the best time to begin warm
up. The outside air dampers remain closed, the heating coil modulates to maintain 75 degF return air temperature. VFD modulate as required to maintain duct static pressure setpoint. The unit operates in this mode until all zones have reached minimum heating setpoint.
SAFETIES:
Duct mounted supply and return duct detectors which shut fan off, close the outside air dampers and VFD.
The unit is also provided with a heating coil discharge air low limit sensor which stops the unit, closes the outside air dampers and opens the heating coil valve to full flow through the coil whenever the low limit is tripped.
HWS
HWR
NC
COM
NO
T1 T2
GREYSTONE WATER DETECTOR
COM
N.O.
WD100
+ (n)
24VAC
CP63D
DEV502300
JAAB AH2 FAN SS
BAC.502300.BO01
= ON
DEV502300
JAAB AH2 FAN ST
BAC.502300.BI06
= ON
DEV502300
JAAB AH2 FLTR ST
BAC.502300.BI07
= CLEAN
DEV502300
JAAB AH2 FREEZE
BAC.502300.BI08
= OFF
DEV502300
JAAB AH2 RA TP
BAC.502300.AI04
-58 - 302°F
DEV502300
JAAB AH2 ECONO MIN
BAC.502300.AO02
0-10VDC
DEV502300
JAAB AH2 HWC VLV
BAC.502300.AO03
0-10VDC
DEV502300
JAAB AH2 AM TP
BAC.502300.AI03
-58 - 302°F
DEV502300
JAAB AH2 SF VFD SPD
BAC.502300.AO05
0-10VDC
DEV502300
JAAB AH2 DA TP
BAC.502300.AI02
-58 - 302°F
DEV502300
JAAB AH2 CWC VLV
BAC.502300.AO04
0-10VDC
DEV502300
JAAB AH2 DA SP
BAC.502300.AI05
0-3" W.C.
DEV502300
AHU1 WTR FLR
BAC.502300.BI09
= OFF
VFD
V2V1
QTY
T1,2
SYMBOL
DUCT AVERAGING TEMP. SENSOR, 24' COPPER
MANUFACTURER
DESCRIPTION PART #
400152 DELTA
BILL OF MATERIAL
FLOOR WATER DETECTION SWITCH
WD100
WD-100
GREYSTONE
DEV502300
JAAB AH2 ECONO MAX
BAC.502300.AO07
0-10VDC
BILL OF MATERIALS
ID#
QUANTITY
TAG PART DESCRIPTION TYPE
63199 3 ACT-5 AF24-MFT US 133 IN LB 24VAC MFT. ACT. SPR RET FIELD
2 REQ'D
x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
15 OF
B A F B
B
A H
U
F l a g r a m d w g
S H
E E T
T I T L E
C
B A F B
B
V A V
U p g r a d e
J o n
W i l s o n
R D
M
S o u t h
A s p e n
B u c k l e y
A F B
C o l o r a d o
M H
AutoCAD SHX Text
ACT-5
AutoCAD SHX Text
ACT-5
ACT-5
F B
B
C O
N T R O
L
P A N
E L
C P
D
E T A I L
BAFB B1005 CONTROL PANEL CP200 DETAIL
C o p y r i g h t
P r o t e c t i o n
F o r
D r a w i n g s
T h e d r a w i n g s s p e c i f i c a t i o n s a n d o t h e r d o c u m e n t s p r e p a r e d b y
S e t p o i n t
S y s t e m s
C o r p o r a t i o n f o r t h i s p r o j e c t a r e i n s t r u m e n t s o f
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s s e r v i c e f o r u s e s o l e l y w i t h r e s p e c t t o t h i s p r o j e c t a n d u n l e s s o t h e r w i s e p r o v i d e d
S e t p o i n t
S y s t e m s
C o r p o r a t i o n s h a l l b e d e e m e d t h e a u t h o r o f t h e s e d o c u m e n t s a n d s h a l l r e t a i n a l l c o m m o n l a w s t a t u t o r y a n d o t h e r r e s e r v e d r i g h t s i n c l u d i n g t h e c o p y r i g h t
ORCA-502000
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
BAC.502000.AI01
B1005 LAWN FLOW MTR
BAC.502000.BI02
B1005 RAIN SENSOR
BAC.502000.AI03
B1005 WIND SPD
BAC.502000.AI04
B1005 WIND DIR
BAC.502000.AI05
B1005 OSA TEMP
BAC.502000.AI06
B1005 OSA RH
BAC.502000.XI07
BAC.502000.XI08
BAC.502000.XI09
BAC.502000.XI10
BAC.502000.XI11
BAC.502000.XI12
BAC.502000.XI13
BAC.502000.XI14
BAC.502000.XI15
BAC.502000.XI16
BAC.502000.XI17
BAC.502000.XI18
BAC.502000.XI19
BAC.502000.XI20
BAC.502000.XI21
BAC.502000.XI22
BAC.502000.XI23
BAC.502000.XI24
BAC.502000.XI25
BAC.502000.XI26
BAC.502000.XI27
BAC.502000.XI28
BAC.502000.XI29
BAC.502000.XI30
BAC.502000.XI31
BAC.502000.XI32
BAC.502000.BO01
B1005 ZONE1 SS
BAC.502000.BO02
B1005 ZONE2 SS
BAC.502000.BO03
B1005 ZONE3 SS
BAC.502000.BO04
B1005 ZONE4 SS
BAC.502000.BO05
B1005 ZONE5 SS
BAC.502000.BO06
B1005 ZONE6 SS
BAC.502000.BO07
B1005 ZONE7 SS
BAC.502000.BO08
B1005 ZONE8 SS
BAC.502000.BO09
B1005 ZONE9 SS
BAC.502000.BO10
B1005 ZONE10 SS
BAC.502000.BO11
B1005 ZONE11 SS
BAC.502000.BO12
B1005 ZONE12 SS
BAC.502000.BO13
B1005 ZONE13 SS
BAC.502000.BO14
B1005 ZONE14 SS
BAC.502000.BO15
B1005 ZONE15 SS
BAC.502000.BO16
B1005 ZONE16 SS
BILL OF MATERIALS
GND
DETAIL 1
DETAIL 1
CP502000
DETAIL 1
DETAIL 1
DETAIL 1
DETAIL 1
INPUT JUMPER
V
LOOP POWERED 4-20mA
FIELD DEVICE
PS()
V
ORCA
18TP
DETAIL 1
O
H M m
A
K
O
H M
O
H M
K
O
H M
J U
M P E R
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
BAC.502000.XI101
BAC.502000.XI102
BAC.502000.XI103
BAC.502000.XI104
BAC.502000.XI105
BAC.502000.XI106
BAC.502000.xI107
BAC.502000.xI108
BAC.502000.BO101
B1005 ZONE17 SS
BAC.502000.BO102
B1005 ZONE18 SS
BAC.502000.BO103
B1005 ZONE19 SS
BAC.502000.BO104
B1005 ZONE20 SS
BAC.502000.BO105
B1005 ZONE21 SS
BAC.502000.BO106
B1005 MASTER ZONE SS
BAC.502000.XO107
BAC.502000.XO108
EXP101
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DETAIL 3
DIGITAL INPUT
18TP
DETAIL 2
J U
M P E R
K
O
H M
INPUT JUMPER
V
V
F u t u r e m
A
F u t u r e
F u t u r e
MODULAR RELAY
RELAY
15AMP
120V
ORCA
AC/DC
COM
10-30V
STATUS
LED
NO
DETAIL 3
COM
NC
Black background.
CP502000
20 inches i n c h e s
White letters on
PANEL ADDRESS
X
32 X
X
X
X
O F F
X
O N
X
X
X
X x
L i t t l e t o n
C o l o r a
S o u t h P a r k
C i r c l e
I n t e r n e t h t t p w w w s e t p o i n t s y s t e m s c o m
E N
G I N
E E R
P R O
J E C T
M
A N
A G
E R
J O
B
N
U M
B E R
D R A W
I N
G
D
A T E
J O
B
N
A M
E
D W
G
F I L E
N
A M
E
A S B U
I L T
D
T E
D W
G
R E V I S I O
N
D
A T E
D A T E
R E V I E W
E D
J O
B
L O
C A T I O
N
D W
G
R E V I S I O
N
A S B U
I L T
D
W G
S
B Y
R E V I E W
1…