This is a BMP Inspection Report Record Summary for the City of Palm Bay, Florida, documenting the inspection of stormwater management structures conducted on January 8, 2026. The inspection evaluated seventeen total structures across the Port Malabar Boulevard NE property in Palm Bay, comprising twelve Drop Inlet-Insert units, two Manhole units, and three Vault/Tank units. Of the seventeen structures inspected, sixteen received a Rate 2 (Standard Cleaning) maintenance rating, indicating that standard cleaning services are recommended for the majority of inspected structures. All inspected units were assigned to Oldcastle Maintenance, the designated maintenance contractor. The inspection was conducted by Aaron Kimmell with property contact Brant Hoffman of Palm Bay. All units had good condition access covers and baskets where applicable, with no filters present in any of the Drop Inlet-Insert or Manhole structures.

The inspection details reveal that the Drop Inlet-Insert structures (Unit IDs 10, 30, 31, 32, 34, 35, 36, 37, 38, 40, 41, and 48) contained standard trash and organic materials requiring maintenance, with most units featuring manhole-type access covers and dimensions ranging from 24 to 80 inches in length and 20 to 89 inches in width. The Manhole structures (Unit IDs 39 and 66) contained organic materials and standard trash with no visible damage to internal components. The three Vault/Tank structures (Unit IDs 65, 72, and 78) were Oldcastle NSBB or Contech DSBB model systems with three chambers each, sediment depths ranging from 2 to 6 inches, and internal screens showing no visible damage. All three vault structures received Rate 2 maintenance ratings and showed good access cover conditions with no visible internal component damage or high water level indicator activation. Unit 78 featured a Stormboom in good condition, while Units 65 and 72 featured Skimmer and Hydrocarbon Boom components respectively, all in serviceable condition.

View the file

Other files

File Type Posted
27-ITB-26_Storm_Structures_-_2024-07-10_Inspection_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Addendum_1.pdf PDF
27-ITB-26_Storm_Structures_-_Solicitation.pdf PDF
27-ITB-26_Storm_Structures_-_11-10-25_1_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-20_Palm_Bay_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-31_Palm_Bay_NSBB_Cleaning_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Map.pdf PDF
27-ITB-26_Storm_Structures_-_2024-10-01_Palm_Bay_NSBB_Cleaning.pdf PDF
27-ITB-26_Storm_Structures_-_Map.pdf PDF
27-ITB-26_Storm_Structures_-_Map_Title_Sheet.pdf PDF
27-ITB-26_Storm_Structures_-_11-10-25_1_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-20_Palm_Bay_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-31_Palm_Bay_NSBB_Cleaning_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Bid_Table_BT-13NP.xlsx XLSX spreadsheet
27-ITB-26_Storm_Structures_-_S031599B_-_City_of_Palm_Bay_10.14.2025.pdf PDF
27-ITB-26_Storm_Structures_-_2024-10-01_Palm_Bay_NSBB_Cleaning.pdf PDF
27-ITB-26_Storm_Structures_-_Bid_Table_BT-13NP.xlsx XLSX spreadsheet
27-ITB-26_Storm_Structures_-_Clean_report_2026-01-08.pdf PDF
27-ITB-26_Storm_Structures_-_Map_Title_Sheet.pdf PDF
27-ITB-26_Storm_Structures_-_S031599B_-_City_of_Palm_Bay_10.14.2025.pdf PDF
27-ITB-26_Storm_Structures_-_Solicitation.pdf PDF
27-ITB-26_Storm_Structures_-_2024-07-10_Inspection_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Addendum_1.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BMP Inspection Report

Record Summary

Table 1: Record Summary

Summary Total Count Rate 1 - Minor Cleaning Rate 2 - Standard Cleaning Rate 3 - Major Cleaning Rate 4 - Extreme Conditions

Total selected records 17 0 16 0 0

Drop Inlet - Insert 12 0 12 0 0

Drop Inlet - No Insert 0 0 0 0 0

Manhole 2 0 1 0 0

Drywell 0 0 0 0 0

Vault / Tank 3 0 3 0 0

Biofiltration / Planter 0 0 0 0 0

Detention / Storage 0 0 0 0 0

Other 0 0 0 0 0

Property Summary:

Property Name: Palm Bay

Property Address: Port Malabar Blvd NE, Palm Bay, FL, 32905, USA

Inspector Name: Aaron Kimmell

Property Contact Name: Brant Hoffman

Property Contact Organization: Palm Bay

Unit Summary

Table 2: Unit Summary

System Type Rate 1 - Minor Cleaning Rate 2 - Standard Cleaning Rate 3 - Major Cleaning Rate 4 - Extreme Conditions

Drop Inlet - Insert 10, 30, 31, 32, 34, 35, 36, 37, 38, 40, 41, 48

Drop Inlet - No Insert

Manhole 39

Drywell

Vault / Tank 65, 72, 78

Biofiltration / Planter

Detention / Storage

Other

Summary Map

Unit Location

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 10

Secondary ID Pmsd76

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Grate

Access Cover Condition Good

Dimension Length 36.0

Dimension Width 24.0

Dimension Depth 18.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Standard Trash,Organics

Is maintenance recommended Yes

Oldcastle Maintenance Rating Rate 2

Media Summary Catch Basin / Drop Inlet - Insert

Photo(s)

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 30

Secondary ID 43Sd01

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 69.0

Dimension Width 89.0

Dimension Depth 46.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Standard Trash,Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 31

Secondary ID 43Sd25C

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 60.0

Dimension Width 72.0

Dimension Depth 48.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 32

Secondary ID 43Sd25B

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 62.0

Dimension Width 58.0

Dimension Depth 46.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 34

Secondary ID 43Sd25E

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 72.0

Dimension Width 58.0

Dimension Depth 45.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 35

Secondary ID 43Sd25D

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 62.0

Dimension Width 54.0

Dimension Depth 32.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 36

Secondary ID 43Sd25F

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 58.0

Dimension Width 60.0

Dimension Depth 45.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 37

Secondary ID 43Sd25H

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 68.0

Dimension Width 56.0

Dimension Depth 48.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Standard Trash,Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 38

Secondary ID 43Sd25G

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 80.0

Dimension Width 68.0

Dimension Depth 48.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 39

Secondary ID 43Sd26D

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Manhole

Manhole Inspection Date: 2026-01-08

Category Other

Manhole Diameter feet 2.0

Access Cover Condition Good

Are there internal components present? Yes

Condition of the internal components Good

Type of Material in System Organics,Standard Trash

Manhole

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 40

Secondary ID 43Sd26C

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 54.0

Dimension Width 45.0

Dimension Depth 40.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics,Standard Trash

Is maintenance recommended No

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 41

Secondary ID 43Sd26B

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Manhole

Access Cover Condition Good

Dimension Length 24.0

Dimension Width 24.0

Dimension Depth 18.0

Is a basket present Yes

Condition of the basket Good

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 48

Secondary ID Pmsd02

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Catch Basin Insert

Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08

Access Cover Type Grate

Access Cover Condition Good

Dimension Length 24.0

Dimension Width 20.0

Dimension Depth 24.0

Is a basket present No

Is a filter present No

Type of Material in System Organics

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 65

Secondary ID Kssd31

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Vault Tank

Vault / Tank Inspection Date: 2026-01-08

What is the overall length of the vault (feet)? 12.0

What is the overall width of the vault (feet)? 5.0

What is the overall depth of the vault (feet)? 6.0

What is the treatment category for the system? Hds

HDS Product Oldcastle Nsbb

NSBB Model Nsbb 612

DSBB Model Unknown

Access Cover Condition Good

Is an inlet bay present? No

How many chambers are present in vault? 3

Is there visible damage to internal components? No

Vault / Tank Inspection Date: 2026-01-08

Has the high water level indicator been activated?

No

Sediment Depth (inches) 5.0

Internal Screen Condition No Visible Damage

Volume of Material Within the Screen System 25 50

Skimmer Condition No Visible Damage

Is a Stormboom present? No

Is maintenance recommended? Yes

Vault / Tank

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 66

Secondary ID Trsd43

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Manhole

Manhole Inspection Date: 2026-01-08

Category Other

Manhole Diameter feet 2.8

Are there internal components present? Yes

Condition of the internal components Good

Filter Type/Notes Unknown

Manhole

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 72

Secondary ID 03Sd05B

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Vault Tank

Vault / Tank Inspection Date: 2026-01-08

What is the overall length of the vault (feet)? 13.0

What is the overall width of the vault (feet)? 6.0

What is the overall depth of the vault (feet)? 8.0

What is the treatment category for the system? Hds

HDS Product Contech Dsbb

DSBB Model Unknown

Access Cover Condition Good

Is an inlet bay present? No

How many chambers are present in vault? 3

Is there visible damage to internal components? No

Has the high water level indicator been activated?

No

Sediment Depth (inches) 2.0

Internal Screen Condition No Visible Damage

Volume of Material Within the Screen System 25 50

Hydrocarbon Boom Good

Rigging & Inspection Details Inspection Date: 2026-01-08

Unit ID 78

Secondary ID Fvsd02

Safe Parking Yes

Traffic Control Assistance No

Rigging Distance to Unit None

System Type Vault Tank

Vault / Tank Inspection Date: 2026-01-08

What is the overall length of the vault (feet)? 12.0

What is the overall width of the vault (feet)? 6.0

What is the overall depth of the vault (feet)? 9.0

What is the treatment category for the system? Hds

HDS Product Oldcastle Nsbb

NSBB Model Nsbb 612

DSBB Model Unknown

Access Cover Condition Good

Is an inlet bay present? No

How many chambers are present in vault? 3

Is there visible damage to internal components? No

Has the high water level indicator been activated?

No

Sediment Depth (inches) 6.0

Volume of Material Within the Screen System 15 25

Skimmer Condition No Visible Damage

Is a Stormboom present? Yes

Stormboom Condition Good