27-ITB-26_Storm_Structures_-_Clean_report_2026-01-08.pdf
PDF 14 MB Posted
- Attached to
- Storm Structures
- Solicitation number
- 27-ITB-26
- Issued by
- Brevard County, Florida
About this file
This is a BMP (Best Management Practice) Inspection Report Record documenting stormwater structure inspections conducted by the City of Palm Bay, Florida on January 8, 2026. The report details the inspection and documentation of 17 stormwater structures located at Port Malabar Boulevard NE in Palm Bay, including 12 drop inlet structures with inserts, 1 manhole, and 3 vault/tank systems. Inspector Aaron Kimmell, working under the direction of property contact Brant Hoffman, conducted comprehensive assessments of each structure, documenting dimensions, access cover conditions, presence of baskets and filters, material accumulation types, and maintenance recommendations. All structures were rated at Rate 2 (Standard Cleaning) maintenance level by Oldcastle, indicating that routine cleaning and maintenance services are required across the inspected facilities.
The inspection findings indicate that all 17 structures examined possess good access cover conditions with no visible internal damage reported. The structures contained standard debris loads including trash and organics, with sediment depths in vault systems ranging from 2 to 6 inches. Maintenance was recommended for 16 of the 17 inspected units, with only one structure (Unit 40) requiring no maintenance at the time of inspection. The three vault/tank systems inspected are equipped with treatment components including screens, skimmers, and in one case a stormboom device. This inspection report supports the City of Palm Bay's solicitation 27-ITB-26 for qualified vendors to perform inspection, cleaning, and documentation services for stormwater structures throughout the municipality.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BMP Inspection Report
Record Summary
Table 1: Record Summary
Summary Total Count Rate 1 - Minor Cleaning Rate 2 - Standard Cleaning Rate 3 - Major Cleaning Rate 4 - Extreme Conditions
Total selected records 17 0 16 0 0
Drop Inlet - Insert 12 0 12 0 0
Drop Inlet - No Insert 0 0 0 0 0
Manhole 2 0 1 0 0
Drywell 0 0 0 0 0
Vault / Tank 3 0 3 0 0
Biofiltration / Planter 0 0 0 0 0
Detention / Storage 0 0 0 0 0
Other 0 0 0 0 0
Property Summary:
Property Name: Palm Bay
Property Address: Port Malabar Blvd NE, Palm Bay, FL, 32905, USA
Inspector Name: Aaron Kimmell
Property Contact Name: Brant Hoffman
Property Contact Organization: Palm Bay
Unit Summary
Table 2: Unit Summary
System Type Rate 1 - Minor Cleaning Rate 2 - Standard Cleaning Rate 3 - Major Cleaning Rate 4 - Extreme Conditions
Drop Inlet - Insert 10, 30, 31, 32, 34, 35, 36, 37, 38, 40, 41, 48
Drop Inlet - No Insert
Manhole 39
Drywell
Vault / Tank 65, 72, 78
Biofiltration / Planter
Detention / Storage
Other
Summary Map
Unit Location
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 10
Secondary ID Pmsd76
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Grate
Access Cover Condition Good
Dimension Length 36.0
Dimension Width 24.0
Dimension Depth 18.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Standard Trash,Organics
Is maintenance recommended Yes
Oldcastle Maintenance Rating Rate 2
Media Summary Catch Basin / Drop Inlet - Insert
Photo(s)
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 30
Secondary ID 43Sd01
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 69.0
Dimension Width 89.0
Dimension Depth 46.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Standard Trash,Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 31
Secondary ID 43Sd25C
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 60.0
Dimension Width 72.0
Dimension Depth 48.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 32
Secondary ID 43Sd25B
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 62.0
Dimension Width 58.0
Dimension Depth 46.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 34
Secondary ID 43Sd25E
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 72.0
Dimension Width 58.0
Dimension Depth 45.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 35
Secondary ID 43Sd25D
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 62.0
Dimension Width 54.0
Dimension Depth 32.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 36
Secondary ID 43Sd25F
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 58.0
Dimension Width 60.0
Dimension Depth 45.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 37
Secondary ID 43Sd25H
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 68.0
Dimension Width 56.0
Dimension Depth 48.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Standard Trash,Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 38
Secondary ID 43Sd25G
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 80.0
Dimension Width 68.0
Dimension Depth 48.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 39
Secondary ID 43Sd26D
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Manhole
Manhole Inspection Date: 2026-01-08
Category Other
Manhole Diameter feet 2.0
Access Cover Condition Good
Are there internal components present? Yes
Condition of the internal components Good
Type of Material in System Organics,Standard Trash
Manhole
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 40
Secondary ID 43Sd26C
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 54.0
Dimension Width 45.0
Dimension Depth 40.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics,Standard Trash
Is maintenance recommended No
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 41
Secondary ID 43Sd26B
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Manhole
Access Cover Condition Good
Dimension Length 24.0
Dimension Width 24.0
Dimension Depth 18.0
Is a basket present Yes
Condition of the basket Good
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 48
Secondary ID Pmsd02
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Catch Basin Insert
Catch Basin / Drop Inlet - Insert Inspection Date: 2026-01-08
Access Cover Type Grate
Access Cover Condition Good
Dimension Length 24.0
Dimension Width 20.0
Dimension Depth 24.0
Is a basket present No
Is a filter present No
Type of Material in System Organics
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 65
Secondary ID Kssd31
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Vault Tank
Vault / Tank Inspection Date: 2026-01-08
What is the overall length of the vault (feet)? 12.0
What is the overall width of the vault (feet)? 5.0
What is the overall depth of the vault (feet)? 6.0
What is the treatment category for the system? Hds
HDS Product Oldcastle Nsbb
NSBB Model Nsbb 612
DSBB Model Unknown
Access Cover Condition Good
Is an inlet bay present? No
How many chambers are present in vault? 3
Is there visible damage to internal components? No
Vault / Tank Inspection Date: 2026-01-08
Has the high water level indicator been activated?
No
Sediment Depth (inches) 5.0
Internal Screen Condition No Visible Damage
Volume of Material Within the Screen System 25 50
Skimmer Condition No Visible Damage
Is a Stormboom present? No
Is maintenance recommended? Yes
Vault / Tank
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 66
Secondary ID Trsd43
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Manhole
Manhole Inspection Date: 2026-01-08
Category Other
Manhole Diameter feet 2.8
Are there internal components present? Yes
Condition of the internal components Good
Filter Type/Notes Unknown
Manhole
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 72
Secondary ID 03Sd05B
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Vault Tank
Vault / Tank Inspection Date: 2026-01-08
What is the overall length of the vault (feet)? 13.0
What is the overall width of the vault (feet)? 6.0
What is the overall depth of the vault (feet)? 8.0
What is the treatment category for the system? Hds
HDS Product Contech Dsbb
DSBB Model Unknown
Access Cover Condition Good
Is an inlet bay present? No
How many chambers are present in vault? 3
Is there visible damage to internal components? No
Has the high water level indicator been activated?
No
Sediment Depth (inches) 2.0
Internal Screen Condition No Visible Damage
Volume of Material Within the Screen System 25 50
Hydrocarbon Boom Good
Rigging & Inspection Details Inspection Date: 2026-01-08
Unit ID 78
Secondary ID Fvsd02
Safe Parking Yes
Traffic Control Assistance No
Rigging Distance to Unit None
System Type Vault Tank
Vault / Tank Inspection Date: 2026-01-08
What is the overall length of the vault (feet)? 12.0
What is the overall width of the vault (feet)? 6.0
What is the overall depth of the vault (feet)? 9.0
What is the treatment category for the system? Hds
HDS Product Oldcastle Nsbb
NSBB Model Nsbb 612
DSBB Model Unknown
Access Cover Condition Good
Is an inlet bay present? No
How many chambers are present in vault? 3
Is there visible damage to internal components? No
Has the high water level indicator been activated?
No
Sediment Depth (inches) 6.0
Volume of Material Within the Screen System 15 25
Skimmer Condition No Visible Damage
Is a Stormboom present? Yes
Stormboom Condition Good
File details come from the government source that posted it. Updated .