About this file
This is a Best Management Practice (BMP) inspection report prepared for the City of Palm Bay, Florida, documenting the inspection of stormwater structures at 2749 School Drive NE, Palm Bay, Florida, conducted on March 20, 2025, by inspector Aaron Kimmell. The report covers 16 separate BMP inspections comprising a mix of Oldcastle NSBB vault/tank systems, detention/storage structures, and other stormwater treatment systems. The inspections documented system dimensions, access cover conditions, internal component assessments, chamber information including water depth and sediment accumulation, and trash/debris present within each structure. Systems inspected included models NSBB-612 and NSBB-1020 vaults, concrete detention structures, and specialized systems such as a Stormceptor unit. Access to all inspected systems was confirmed as available, with most locations requiring rigging distances of 10-125 feet and no traffic control assistance needed. The majority of systems were in good condition with no visible damage to key components; however, maintenance was recommended for two units (BMP Inspection 6 and BMP Inspection 9) based on debris accumulation and water levels observed.
The inspection findings indicate that floatable materials and organic debris were present in most trash racks across the vault and tank systems, with concentrations ranging from 0-75 percent full, while 98-100 percent of debris material was organic in composition. Water depths across chambers ranged from 2 to 72 inches, with minimal sediment accumulation noted in most units, though sediment depths up to 12 inches were recorded in specific systems. All access covers examined were in good condition, and most systems with upflow filters showed locked and properly functioning components. The inspection report includes comprehensive photographic documentation of all 16 systems and represents the baseline condition assessment necessary for the City of Palm Bay's stormwater structure maintenance and management program.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Oldcastle BMP Inspection Palm Bay Complete
Site Name or Description Palm Bay
Site Location 2749 School Dr NE Palm Bay FL 32905
United States (28.028724313533367, -80.58982616618707)
Inspector Name Aaron Kimmell
Inspection Date 20.03.2025 09:19 EDT
Contact Name Brant Hoffman
1.InspectionDetails
Inspection Details 1.1.BMPInspection
BMP Inspection 1.1.1.BMPInspection1
BMP Inspection 1
Unit ID or Number KSSD13
Photo 1
1.1.1.1.RiggingDetails
Rigging Details
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.1.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 15
What is the overall WIDTH of the Vault? (feet) 5
What is the overall DEPTH of the vault? (feet) 5
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.1.2.1.AccessCovers
Access Covers
Access Cover Type Manhole
Access Cover Condition Good Condition
Photo 2 Photo 3 Photo 4
1.1.1.2.2.InternalAssessment
Internal Assessment 1.1.1.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 25-50% Full
What type of Material is present? Organics (Leaves, sticks, etc.)
What percentage of organics is present? 100 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? Yes
Do the filters appear to be locked? Yes
Photo 5 Photo 6 Photo 7 Photo 8
1.1.1.2.2.2.ChamberInformation
Chamber Information 1.1.1.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 36
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo of Chamber
Photo 9
1.1.1.2.2.2.2.ChamberInformation2
Chamber Information 2
Chamber # or Description 2
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 36
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 10
1.1.1.2.2.2.3.ChamberInformation3
Chamber Information 3
Chamber # or Description 3
Chamber Length 4
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 2
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 11
Is maintenance recommended? No 1.1.2.BMPInspection2
BMP Inspection 2
Unit ID or Number No tag
Photo 12
1.1.2.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.2.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 12
What is the overall WIDTH of the Vault? (feet) 6
What is the overall DEPTH of the vault? (feet) 8
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.2.2.1.AccessCovers
Access Covers
Photo 13
Access Cover Photos
Photo 14 Photo 15 Photo 16
1.1.2.2.2.InternalAssessment
1.1.2.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 15-25% Full
What type of Material is present?
Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
What percentage of organics is present? 98 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? Yes
Photo 17
1.1.2.2.2.2.ChamberInformation
1.1.2.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 40
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 18
1.1.2.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Chamber Length 4
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 42
Depth of Sediment (bottom of vault to top of sediment)
Photo 19
1.1.2.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Chamber Length 4
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 4
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 20
1.1.3.BMPInspection3
BMP Inspection 3
Unit ID or Number Kssd39 1.1.3.1.RiggingDetails
Rigging Details
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.3.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 12
What is the overall WIDTH of the Vault? (feet) 6
What is the overall DEPTH of the vault? (feet) 6
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.3.2.1.AccessCovers
Access Covers
Access Cover Type Manhole
Access Cover Condition Good Condition
Photo 21 Photo 22 Photo 23
1.1.3.2.2.InternalAssessment
1.1.3.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 0-15% Full
What type of Material is present? Organics (Leaves, sticks, etc.)
What percentage of organics is present? 100 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? Yes
1.1.3.2.2.2.ChamberInformation
Chamber Information 1.1.3.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 48
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 24
1.1.3.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 48
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 25
1.1.3.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 14
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 26
1.1.4.BMPInspection4
BMP Inspection 4
Unit ID or Number Kssd41 1.1.4.1.RiggingDetails
Rigging Details
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) No Rigging Needed
Will Traffic Control assistance be required? No 1.1.4.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 20
What is the overall WIDTH of the Vault? (feet) 10
What is the overall DEPTH of the vault? (feet) 12
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-1020 1.1.4.2.1.AccessCovers
Access Covers
Access Cover Type Manhole
Access Cover Condition Good Condition
Photo 27 Photo 28 Photo 29
1.1.4.2.2.InternalAssessment
1.1.4.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 0-15% Full
What type of Material is present?
Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
What percentage of organics is present? 98 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? No 1.1.4.2.2.2.ChamberInformation
Chamber Information 1.1.4.2.2.2.1.ChamberInformation1
Chamber Information 1
Trash / Debris Material Standard Hydrocarbons
Water Depth (top of water to sediment) (inches) 65
Depth of Sediment (bottom of vault to top of sediment) (inches) 4
Photo 30
1.1.4.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 65
Depth of Sediment (bottom of vault to top of sediment) (inches) 1
Photo 31
1.1.4.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 65
Photo 32
1.1.5.BMPInspection5
BMP Inspection 5
Unit ID or Number Cssd29
Photo 33
1.1.5.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.5.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Detention / Storage
Type of Detention System Concrete Structure
Detention System Type Other
Howmany access points are available 4
Access Cover Type Hatch
Access Cover Condition Good Condition
System Depth (feet) 8
Number of Modules / Systems 4
Is trash present in system? No
Is water present in the system? Yes
Water depth (top of water to sediment) (inches) 14
Is sediment present in system? No
Photos of Detention System
Photo 34 Photo 35 Photo 36 Photo 37
1.1.6.BMPInspection6
BMP Inspection 6
Unit ID or Number Fvsd02 1.1.6.1.RiggingDetails
Rigging Details
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) No Rigging Needed
Will Traffic Control assistance be required? No 1.1.6.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 12
What is the overall WIDTH of the Vault? (feet) 6
What is the overall DEPTH of the vault? (feet) 8
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.6.2.1.AccessCovers
Access Covers
Access Cover Type Grate
Photo 38 Photo 39 Photo 40
1.1.6.2.2.InternalAssessment
1.1.6.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 25-50% Full
What type of Material is present?
Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
What percentage of organics is present? 97 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? No 1.1.6.2.2.2.ChamberInformation
Chamber Information 1.1.6.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 42
(inches) 1
Photo 41 Photo 42
1.1.6.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Chamber Length 4
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 42
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 43
1.1.6.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 42
Photo 44
Is maintenance recommended? Yes 1.1.7.BMPInspection7
BMP Inspection 7
Unit ID or Number FVSD5B
Photo 45
1.1.7.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.7.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Detention / Storage
Type of Detention System Concrete Structure
Detention System Type Other
Howmany access points are available 4
Access Cover Type Grate
Photo 46 Photo 47 Photo 48 Photo 49
System Depth (feet) 9
Number of Modules / Systems 2
Is trash present in system? No
Is water present in the system? Yes
Water depth (top of water to sediment) (inches) 36
Is sediment present in system? No
Photo 50 Photo 51 Photo 52 Photo 53 Photo 54
1.1.8.BMPInspection8
BMP Inspection 8
Unit ID or Number Cssd44
Photo 55
1.1.8.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.8.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Detention / Storage
Type of Detention System Concrete Structure
Detention System Type Other
Howmany access points are available 3
Photo 56 Photo 57 Photo 58
System Depth (feet) 7
Number of Modules / Systems 2
Photo 59
Water depth (top of water to sediment) (inches) 48
Is sediment present in system? Yes
Sediment depth (inches) 3
Photo 60 Photo 61 Photo 62
1.1.9.BMPInspection9
BMP Inspection 9
Unit ID or Number 3SD05B
Photo 63 Photo 64
1.1.9.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.9.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 12
What is the overall WIDTH of the Vault? (feet) 6
What is the overall DEPTH of the vault? (feet) 9
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.9.2.1.AccessCovers
Access Covers
Access Cover Type Hatch
Access Cover Condition Good Condition
Photo 65 Photo 66 Photo 67
1.1.9.2.2.InternalAssessment
1.1.9.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 50-75% Full
What type of Material is present?
Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
What percentage of organics is present? 95 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? Yes
Photo 68
1.1.9.2.2.2.ChamberInformation
1.1.9.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 48
Depth of Sediment (bottom of vault to top of sediment) (inches) 1
Photo 69
1.1.9.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Chamber Length 4
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 48
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 70
1.1.9.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Chamber Length 4
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 2
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 71
Is maintenance recommended? Yes 1.1.10.BMPInspection10
BMP Inspection 10
Unit ID or Number 04sd03b 1.1.10.1.RiggingDetails
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.10.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Other
Is trash present in system? Yes
Photo 72
Water depth (top of water to sediment) (inches) 32
Is sediment present in system? Yes
Sediment depth (inches) 4
Photo 73 Photo 74 Photo 75 Photo 76
1.1.11.BMPInspection11
BMP Inspection 11
Unit ID or Number PMSD78 1.1.11.1.RiggingDetails
Rigging Details
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.11.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 20
What is the overall WIDTH of the Vault? (feet) 10
What is the overall DEPTH of the vault? (feet) 15
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-1020 1.1.11.2.1.AccessCovers
Access Covers
Access Cover Type Hatch
Access Cover Condition Good Condition
Photo 77 Photo 78
1.1.11.2.2.InternalAssessment
1.1.11.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 0-15% Full
What type of Material is present?
Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
What percentage of organics is present? 98 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? No 1.1.11.2.2.2.ChamberInformation
Chamber Information 1.1.11.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Chamber Length 20
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 72
Depth of Sediment (bottom of vault to top of sediment) (inches) 3
Photo 79 Photo 80 Photo 81 Photo 82 Photo 83
1.1.12.BMPInspection12
BMP Inspection 12
Unit ID or Number 06SD22
Photo 84
1.1.12.1.RiggingDetails
Rigging Distance to Unit (feet) 10 - 125 ft
Will Traffic Control assistance be required? No 1.1.12.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 12
What is the overall WIDTH of the Vault? (feet) 6
What is the overall DEPTH of the vault? (feet) 7
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.12.2.1.AccessCovers
Access Covers
Access Cover Type Hatch
Access Cover Condition Good Condition
Photo 85 Photo 86 Photo 87
1.1.12.2.2.InternalAssessment
1.1.12.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 15-25% Full
What type of Material is present?
Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
What percentage of organics is present? 96 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? No 1.1.12.2.2.2.ChamberInformation
Chamber Information 1.1.12.2.2.2.1.ChamberInformation1
Chamber Information 1
Chamber # or Description 1
Chamber Length 4
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 34
Depth of Sediment (bottom of vault to top of sediment) (inches) 12
Photo 88
1.1.12.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.) Standard Hydrocarbons
Water Depth (top of water to sediment) (inches) 42
Depth of Sediment (bottom of vault to top of sediment) (inches) 4
Photo 89
1.1.12.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 42
Depth of Sediment (bottom of vault to top of sediment) (inches) 0
Photo 90
1.1.13.BMPInspection13
BMP Inspection 13
Unit ID or Number CC1SD16
Photo 91 Photo 92
1.1.13.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) No Rigging Needed
Will Traffic Control assistance be required? No 1.1.13.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Detention / Storage
Type of Detention System Concrete Structure
Detention System Type Other
Howmany access points are available 2
Access Cover Type Manhole
Photo 93 Photo 94
System Depth (feet) 15
Number of Modules / Systems 1
Is trash present in system? No
Is water present in the system? Yes
Water depth (top of water to sediment) (inches) 12
Is sediment present in system? No
Photo 95 Photo 96 Photo 97 Photo 98 Photo 99
1.1.14.BMPInspection14
BMP Inspection 14
Unit ID or Number CC1SD15
Photo 100
1.1.14.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) No Rigging Needed 1.1.14.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Detention / Storage
Type of Detention System Concrete Structure
Detention System Type Other
Howmany access points are available 3
Access Cover Type Manhole
Photo 101 Photo 102 Photo 103
System Depth (feet) 15
Number of Modules / Systems 3
Water depth (top of water to sediment) (inches) 41
Is sediment present in system? No
Photo 104 Photo 105 Photo 106
1.1.15.BMPInspection15
BMP Inspection 15
Unit ID or Number TRSD43
Photo 107
1.1.15.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft 1.1.15.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Other
System Type and Description Stormceptor
Is trash present in system? No
Is water present in the system? Yes
Water depth (top of water to sediment) (inches) 32
Is sediment present in system? Yes
Sediment depth (inches) 12
Photo 108 Photo 109 Photo 110
1.1.16.BMPInspection16
BMP Inspection 16
Unit ID or Number Cssd54
Photo 111
1.1.16.1.RiggingDetails
Is there a safe place to park our cleaning equipment? Yes
Rigging Distance to Unit (feet) 10 - 125 ft 1.1.16.2.InspectionDetails
Inspection Details
Is the system accessible for inspection? Yes
System Type Vault or Tank
What is the overall LENGTH of the vault? (feet) 12
What is the overall WIDTH of the Vault? (feet) 6
What is the overall DEPTH of the vault? (feet) 8
What is the Treatment Category for the system? HDS
Product Oldcastle NSBB
What is the NSBB Model NSBB-612 1.1.16.2.1.AccessCovers
Access Covers
Access Cover Type Manhole
Photo 112 Photo 113 Photo 114
1.1.16.2.2.InternalAssessment
1.1.16.2.2.1.Components
Components
Does this unit have Sungate's installed? No
Is the trash rack present? Yes
What is the condition of the trash rack? No Visible Damage
Are floatable materials present in trash rack? Yes
How full is the trash rack 0-15% Full
What type of Material is present? Organics (Leaves, sticks, etc.)
What percentage of organics is present? 100 From 1 to 100
Does this unit have a floating skimmer? Yes
Is there any visible damage to the skimmer? No
Does this system require a stormboom? No
Is an Upflow filter present? Yes
Photo 115
1.1.16.2.2.2.ChamberInformation
1.1.16.2.2.2.1.ChamberInformation1
Chamber Information 1
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 41
Depth of Sediment (bottom of vault to top of sediment) (inches) 8
Photo 116
1.1.16.2.2.2.2.ChamberInformation2
Chamber # or Description 2
Chamber Length 4
Trash / Debris Material Organics (Leaves, sticks, etc.)
Water Depth (top of water to sediment) (inches) 41
Depth of Sediment (bottom of vault to top of sediment) (inches) 2
Photo 117
1.1.16.2.2.2.3.ChamberInformation3
Chamber # or Description 3
Chamber Length 4
Trash / Debris Material None
Water Depth (top of water to sediment) (inches) 4
Photo 118 Photo 119
2.InspectorInformation
Inspector Information
Inspector Name Aaron Kimmell
Inspector Signature
20.03.2025 13:34 EDT
3.Mediasummary
Media summary
Photo 1 Photo 2
Photo 3 Photo 4
Photo 5 Photo 6
Photo 7 Photo 8
Photo 9 Photo 10
Photo 11 Photo 12
Photo 13 Photo 14
Photo 15 Photo 16
Photo 17 Photo 18
Photo 19 Photo 20
Photo 21 Photo 22
Photo 23 Photo 24
Photo 25 Photo 26
Photo 27 Photo 28
Photo 29 Photo 30
Photo 31 Photo 32
Photo 33 Photo 34
Photo 35 Photo 36
Photo 37 Photo 38
Photo 39 Photo 40
Photo 41 Photo 42
Photo 43 Photo 44
Photo 45 Photo 46
Photo 47 Photo 48
Photo 49 Photo 50
Photo 51 Photo 52
Photo 53 Photo 54
Photo 55 Photo 56
Photo 57 Photo 58
Photo 59 Photo 60
Photo 61 Photo 62
Photo 63 Photo 64
Photo 65 Photo 66
Photo 67 Photo 68
Photo 69 Photo 70
Photo 71 Photo 72
Photo 73 Photo 74
Photo 75 Photo 76
Photo 77 Photo 78
Photo 79 Photo 80
Photo 81 Photo 82
Photo 83 Photo 84
Photo 85 Photo 86
Photo 87 Photo 88
Photo 89 Photo 90
Photo 91 Photo 92
Photo 93 Photo 94
Photo 95 Photo 96
Photo 97 Photo 98
Photo 99 Photo 100
Photo 101 Photo 102
Photo 103 Photo 104
Photo 105 Photo 106
Photo 107 Photo 108
Photo 109 Photo 110
Photo 111 Photo 112
Photo 113 Photo 114
Photo 115 Photo 116
Photo 117 Photo 118
Photo 119
| 1. Inspection Details |
| 1.1. BMP Inspection |
| 1.1.1. BMP Inspection 1 |
| 1.1.1.1. Rigging Details |
| 1.1.1.2. Inspection Details |
| 1.1.1.2.1. Access Covers |
| 1.1.1.2.2. Internal Assessment |
| 1.1.1.2.2.1. Components |
| 1.1.1.2.2.2. Chamber Information |
| 1.1.1.2.2.2.1. Chamber Information 1 |
| 1.1.1.2.2.2.2. Chamber Information 2 |
| 1.1.1.2.2.2.3. Chamber Information 3 |
| 1.1.2. BMP Inspection 2 |
| 1.1.2.1. Rigging Details |
| 1.1.2.2. Inspection Details |
| 1.1.2.2.1. Access Covers |
| 1.1.2.2.2. Internal Assessment |
| 1.1.2.2.2.1. Components |
| 1.1.2.2.2.2. Chamber Information |
| 1.1.2.2.2.2.1. Chamber Information 1 |
| 1.1.2.2.2.2.2. Chamber Information 2 |
| 1.1.2.2.2.2.3. Chamber Information 3 |
| 1.1.3. BMP Inspection 3 |
| 1.1.3.1. Rigging Details |
| 1.1.3.2. Inspection Details |
| 1.1.3.2.1. Access Covers |
| 1.1.3.2.2. Internal Assessment |
| 1.1.3.2.2.1. Components |
| 1.1.3.2.2.2. Chamber Information |
| 1.1.3.2.2.2.1. Chamber Information 1 |
| 1.1.3.2.2.2.2. Chamber Information 2 |
| 1.1.3.2.2.2.3. Chamber Information 3 |
| 1.1.4. BMP Inspection 4 |
| 1.1.4.1. Rigging Details |
| 1.1.4.2. Inspection Details |
| 1.1.4.2.1. Access Covers |
| 1.1.4.2.2. Internal Assessment |
| 1.1.4.2.2.1. Components |
| 1.1.4.2.2.2. Chamber Information |
| 1.1.4.2.2.2.1. Chamber Information 1 |
| 1.1.4.2.2.2.2. Chamber Information 2 |
| 1.1.4.2.2.2.3. Chamber Information 3 |
| 1.1.5. BMP Inspection 5 |
| 1.1.5.1. Rigging Details |
| 1.1.5.2. Inspection Details |
| 1.1.6. BMP Inspection 6 |
| 1.1.6.1. Rigging Details |
| 1.1.6.2. Inspection Details |
| 1.1.6.2.1. Access Covers |
| 1.1.6.2.2. Internal Assessment |
| 1.1.6.2.2.1. Components |
| 1.1.6.2.2.2. Chamber Information |
| 1.1.6.2.2.2.1. Chamber Information 1 |
| 1.1.6.2.2.2.2. Chamber Information 2 |
| 1.1.6.2.2.2.3. Chamber Information 3 |
| 1.1.7. BMP Inspection 7 |
| 1.1.7.1. Rigging Details |
| 1.1.7.2. Inspection Details |
| 1.1.8. BMP Inspection 8 |
| 1.1.8.1. Rigging Details |
| 1.1.8.2. Inspection Details |
| 1.1.9. BMP Inspection 9 |
| 1.1.9.1. Rigging Details |
| 1.1.9.2. Inspection Details |
| 1.1.9.2.1. Access Covers |
| 1.1.9.2.2. Internal Assessment |
| 1.1.9.2.2.1. Components |
| 1.1.9.2.2.2. Chamber Information |
| 1.1.9.2.2.2.1. Chamber Information 1 |
| 1.1.9.2.2.2.2. Chamber Information 2 |
| 1.1.9.2.2.2.3. Chamber Information 3 |
| 1.1.10. BMP Inspection 10 |
| 1.1.10.1. Rigging Details |
| 1.1.10.2. Inspection Details |
| 1.1.11. BMP Inspection 11 |
| 1.1.11.1. Rigging Details |
| 1.1.11.2. Inspection Details |
| 1.1.11.2.1. Access Covers |
| 1.1.11.2.2. Internal Assessment |
| 1.1.11.2.2.1. Components |
| 1.1.11.2.2.2. Chamber Information |
| 1.1.11.2.2.2.1. Chamber Information 1 |
| 1.1.12. BMP Inspection 12 |
| 1.1.12.1. Rigging Details |
| 1.1.12.2. Inspection Details |
| 1.1.12.2.1. Access Covers |
| 1.1.12.2.2. Internal Assessment |
| 1.1.12.2.2.1. Components |
| 1.1.12.2.2.2. Chamber Information |
| 1.1.12.2.2.2.1. Chamber Information 1 |
| 1.1.12.2.2.2.2. Chamber Information 2 |
| 1.1.12.2.2.2.3. Chamber Information 3 |
| 1.1.13. BMP Inspection 13 |
| 1.1.13.1. Rigging Details |
| 1.1.13.2. Inspection Details |
| 1.1.14. BMP Inspection 14 |
| 1.1.14.1. Rigging Details |
| 1.1.14.2. Inspection Details |
| 1.1.15. BMP Inspection 15 |
| 1.1.15.1. Rigging Details |
| 1.1.15.2. Inspection Details |
| 1.1.16. BMP Inspection 16 |
| 1.1.16.1. Rigging Details |
| 1.1.16.2. Inspection Details |
| 1.1.16.2.1. Access Covers |
| 1.1.16.2.2. Internal Assessment |
| 1.1.16.2.2.1. Components |
| 1.1.16.2.2.2. Chamber Information |
| 1.1.16.2.2.2.1. Chamber Information 1 |
| 1.1.16.2.2.2.2. Chamber Information 2 |
| 1.1.16.2.2.2.3. Chamber Information 3 |
| 2. Inspector Information |
| 3. Media summary |