27-ITB-26_Storm_Structures_-_2025-03-20_Palm_Bay_NSBB_Inspection.pdf

PDF 5 MB Posted

Attached to
Storm Structures
Solicitation number
27-ITB-26
Issued by
Brevard County, Florida

About this file

This is a Best Management Practice (BMP) inspection report prepared for the City of Palm Bay, Florida, documenting the inspection of stormwater structures at 2749 School Drive NE, Palm Bay, Florida, conducted on March 20, 2025, by inspector Aaron Kimmell. The report covers 16 separate BMP inspections comprising a mix of Oldcastle NSBB vault/tank systems, detention/storage structures, and other stormwater treatment systems. The inspections documented system dimensions, access cover conditions, internal component assessments, chamber information including water depth and sediment accumulation, and trash/debris present within each structure. Systems inspected included models NSBB-612 and NSBB-1020 vaults, concrete detention structures, and specialized systems such as a Stormceptor unit. Access to all inspected systems was confirmed as available, with most locations requiring rigging distances of 10-125 feet and no traffic control assistance needed. The majority of systems were in good condition with no visible damage to key components; however, maintenance was recommended for two units (BMP Inspection 6 and BMP Inspection 9) based on debris accumulation and water levels observed.

The inspection findings indicate that floatable materials and organic debris were present in most trash racks across the vault and tank systems, with concentrations ranging from 0-75 percent full, while 98-100 percent of debris material was organic in composition. Water depths across chambers ranged from 2 to 72 inches, with minimal sediment accumulation noted in most units, though sediment depths up to 12 inches were recorded in specific systems. All access covers examined were in good condition, and most systems with upflow filters showed locked and properly functioning components. The inspection report includes comprehensive photographic documentation of all 16 systems and represents the baseline condition assessment necessary for the City of Palm Bay's stormwater structure maintenance and management program.

View the file

Other files

File Type Posted
27-ITB-26_Storm_Structures_-_2024-07-10_Inspection_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Addendum_1.pdf PDF
27-ITB-26_Storm_Structures_-_Clean_report_2026-01-08.pdf PDF
27-ITB-26_Storm_Structures_-_Solicitation.pdf PDF
27-ITB-26_Storm_Structures_-_11-10-25_1_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-31_Palm_Bay_NSBB_Cleaning_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Map.pdf PDF
27-ITB-26_Storm_Structures_-_2024-10-01_Palm_Bay_NSBB_Cleaning.pdf PDF
27-ITB-26_Storm_Structures_-_Map.pdf PDF
27-ITB-26_Storm_Structures_-_Map_Title_Sheet.pdf PDF
27-ITB-26_Storm_Structures_-_2024-10-01_Palm_Bay_NSBB_Cleaning.pdf PDF
27-ITB-26_Storm_Structures_-_Bid_Table_BT-13NP.xlsx XLSX spreadsheet
27-ITB-26_Storm_Structures_-_Clean_report_2026-01-08.pdf PDF
27-ITB-26_Storm_Structures_-_Map_Title_Sheet.pdf PDF
27-ITB-26_Storm_Structures_-_S031599B_-_City_of_Palm_Bay_10.14.2025.pdf PDF
27-ITB-26_Storm_Structures_-_Solicitation.pdf PDF
27-ITB-26_Storm_Structures_-_2024-07-10_Inspection_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Addendum_1.pdf PDF
27-ITB-26_Storm_Structures_-_11-10-25_1_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-20_Palm_Bay_NSBB_Inspection.pdf PDF
27-ITB-26_Storm_Structures_-_2025-03-31_Palm_Bay_NSBB_Cleaning_Report.pdf PDF
27-ITB-26_Storm_Structures_-_Bid_Table_BT-13NP.xlsx XLSX spreadsheet
27-ITB-26_Storm_Structures_-_S031599B_-_City_of_Palm_Bay_10.14.2025.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Oldcastle BMP Inspection Palm Bay Complete

Site Name or Description Palm Bay

Site Location 2749 School Dr NE Palm Bay FL 32905

United States (28.028724313533367, -80.58982616618707)

Inspector Name Aaron Kimmell

Inspection Date 20.03.2025 09:19 EDT

Contact Name Brant Hoffman

1.InspectionDetails

Inspection Details 1.1.BMPInspection

BMP Inspection 1.1.1.BMPInspection1

BMP Inspection 1

Unit ID or Number KSSD13

Photo 1

1.1.1.1.RiggingDetails

Rigging Details

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.1.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 15

What is the overall WIDTH of the Vault? (feet) 5

What is the overall DEPTH of the vault? (feet) 5

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.1.2.1.AccessCovers

Access Covers

Access Cover Type Manhole

Access Cover Condition Good Condition

Photo 2 Photo 3 Photo 4

1.1.1.2.2.InternalAssessment

Internal Assessment 1.1.1.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 25-50% Full

What type of Material is present? Organics (Leaves, sticks, etc.)

What percentage of organics is present? 100 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? Yes

Do the filters appear to be locked? Yes

Photo 5 Photo 6 Photo 7 Photo 8

1.1.1.2.2.2.ChamberInformation

Chamber Information 1.1.1.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 36

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo of Chamber

Photo 9

1.1.1.2.2.2.2.ChamberInformation2

Chamber Information 2

Chamber # or Description 2

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 36

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 10

1.1.1.2.2.2.3.ChamberInformation3

Chamber Information 3

Chamber # or Description 3

Chamber Length 4

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 2

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 11

Is maintenance recommended? No 1.1.2.BMPInspection2

BMP Inspection 2

Unit ID or Number No tag

Photo 12

1.1.2.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.2.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 12

What is the overall WIDTH of the Vault? (feet) 6

What is the overall DEPTH of the vault? (feet) 8

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.2.2.1.AccessCovers

Access Covers

Photo 13

Access Cover Photos

Photo 14 Photo 15 Photo 16

1.1.2.2.2.InternalAssessment

1.1.2.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 15-25% Full

What type of Material is present?

Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

What percentage of organics is present? 98 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? Yes

Photo 17

1.1.2.2.2.2.ChamberInformation

1.1.2.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 40

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 18

1.1.2.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Chamber Length 4

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 42

Depth of Sediment (bottom of vault to top of sediment)

Photo 19

1.1.2.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Chamber Length 4

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 4

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 20

1.1.3.BMPInspection3

BMP Inspection 3

Unit ID or Number Kssd39 1.1.3.1.RiggingDetails

Rigging Details

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.3.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 12

What is the overall WIDTH of the Vault? (feet) 6

What is the overall DEPTH of the vault? (feet) 6

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.3.2.1.AccessCovers

Access Covers

Access Cover Type Manhole

Access Cover Condition Good Condition

Photo 21 Photo 22 Photo 23

1.1.3.2.2.InternalAssessment

1.1.3.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 0-15% Full

What type of Material is present? Organics (Leaves, sticks, etc.)

What percentage of organics is present? 100 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? Yes

1.1.3.2.2.2.ChamberInformation

Chamber Information 1.1.3.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 48

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 24

1.1.3.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 48

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 25

1.1.3.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 14

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 26

1.1.4.BMPInspection4

BMP Inspection 4

Unit ID or Number Kssd41 1.1.4.1.RiggingDetails

Rigging Details

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) No Rigging Needed

Will Traffic Control assistance be required? No 1.1.4.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 20

What is the overall WIDTH of the Vault? (feet) 10

What is the overall DEPTH of the vault? (feet) 12

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-1020 1.1.4.2.1.AccessCovers

Access Covers

Access Cover Type Manhole

Access Cover Condition Good Condition

Photo 27 Photo 28 Photo 29

1.1.4.2.2.InternalAssessment

1.1.4.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 0-15% Full

What type of Material is present?

Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

What percentage of organics is present? 98 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? No 1.1.4.2.2.2.ChamberInformation

Chamber Information 1.1.4.2.2.2.1.ChamberInformation1

Chamber Information 1

Trash / Debris Material Standard Hydrocarbons

Water Depth (top of water to sediment) (inches) 65

Depth of Sediment (bottom of vault to top of sediment) (inches) 4

Photo 30

1.1.4.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 65

Depth of Sediment (bottom of vault to top of sediment) (inches) 1

Photo 31

1.1.4.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 65

Photo 32

1.1.5.BMPInspection5

BMP Inspection 5

Unit ID or Number Cssd29

Photo 33

1.1.5.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.5.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Detention / Storage

Type of Detention System Concrete Structure

Detention System Type Other

Howmany access points are available 4

Access Cover Type Hatch

Access Cover Condition Good Condition

System Depth (feet) 8

Number of Modules / Systems 4

Is trash present in system? No

Is water present in the system? Yes

Water depth (top of water to sediment) (inches) 14

Is sediment present in system? No

Photos of Detention System

Photo 34 Photo 35 Photo 36 Photo 37

1.1.6.BMPInspection6

BMP Inspection 6

Unit ID or Number Fvsd02 1.1.6.1.RiggingDetails

Rigging Details

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) No Rigging Needed

Will Traffic Control assistance be required? No 1.1.6.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 12

What is the overall WIDTH of the Vault? (feet) 6

What is the overall DEPTH of the vault? (feet) 8

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.6.2.1.AccessCovers

Access Covers

Access Cover Type Grate

Photo 38 Photo 39 Photo 40

1.1.6.2.2.InternalAssessment

1.1.6.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 25-50% Full

What type of Material is present?

Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

What percentage of organics is present? 97 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? No 1.1.6.2.2.2.ChamberInformation

Chamber Information 1.1.6.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 42

(inches) 1

Photo 41 Photo 42

1.1.6.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Chamber Length 4

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 42

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 43

1.1.6.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 42

Photo 44

Is maintenance recommended? Yes 1.1.7.BMPInspection7

BMP Inspection 7

Unit ID or Number FVSD5B

Photo 45

1.1.7.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.7.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Detention / Storage

Type of Detention System Concrete Structure

Detention System Type Other

Howmany access points are available 4

Access Cover Type Grate

Photo 46 Photo 47 Photo 48 Photo 49

System Depth (feet) 9

Number of Modules / Systems 2

Is trash present in system? No

Is water present in the system? Yes

Water depth (top of water to sediment) (inches) 36

Is sediment present in system? No

Photo 50 Photo 51 Photo 52 Photo 53 Photo 54

1.1.8.BMPInspection8

BMP Inspection 8

Unit ID or Number Cssd44

Photo 55

1.1.8.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.8.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Detention / Storage

Type of Detention System Concrete Structure

Detention System Type Other

Howmany access points are available 3

Photo 56 Photo 57 Photo 58

System Depth (feet) 7

Number of Modules / Systems 2

Photo 59

Water depth (top of water to sediment) (inches) 48

Is sediment present in system? Yes

Sediment depth (inches) 3

Photo 60 Photo 61 Photo 62

1.1.9.BMPInspection9

BMP Inspection 9

Unit ID or Number 3SD05B

Photo 63 Photo 64

1.1.9.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.9.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 12

What is the overall WIDTH of the Vault? (feet) 6

What is the overall DEPTH of the vault? (feet) 9

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.9.2.1.AccessCovers

Access Covers

Access Cover Type Hatch

Access Cover Condition Good Condition

Photo 65 Photo 66 Photo 67

1.1.9.2.2.InternalAssessment

1.1.9.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 50-75% Full

What type of Material is present?

Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

What percentage of organics is present? 95 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? Yes

Photo 68

1.1.9.2.2.2.ChamberInformation

1.1.9.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 48

Depth of Sediment (bottom of vault to top of sediment) (inches) 1

Photo 69

1.1.9.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Chamber Length 4

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 48

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 70

1.1.9.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Chamber Length 4

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 2

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 71

Is maintenance recommended? Yes 1.1.10.BMPInspection10

BMP Inspection 10

Unit ID or Number 04sd03b 1.1.10.1.RiggingDetails

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.10.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Other

Is trash present in system? Yes

Photo 72

Water depth (top of water to sediment) (inches) 32

Is sediment present in system? Yes

Sediment depth (inches) 4

Photo 73 Photo 74 Photo 75 Photo 76

1.1.11.BMPInspection11

BMP Inspection 11

Unit ID or Number PMSD78 1.1.11.1.RiggingDetails

Rigging Details

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.11.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 20

What is the overall WIDTH of the Vault? (feet) 10

What is the overall DEPTH of the vault? (feet) 15

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-1020 1.1.11.2.1.AccessCovers

Access Covers

Access Cover Type Hatch

Access Cover Condition Good Condition

Photo 77 Photo 78

1.1.11.2.2.InternalAssessment

1.1.11.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 0-15% Full

What type of Material is present?

Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

What percentage of organics is present? 98 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? No 1.1.11.2.2.2.ChamberInformation

Chamber Information 1.1.11.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Chamber Length 20

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 72

Depth of Sediment (bottom of vault to top of sediment) (inches) 3

Photo 79 Photo 80 Photo 81 Photo 82 Photo 83

1.1.12.BMPInspection12

BMP Inspection 12

Unit ID or Number 06SD22

Photo 84

1.1.12.1.RiggingDetails

Rigging Distance to Unit (feet) 10 - 125 ft

Will Traffic Control assistance be required? No 1.1.12.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 12

What is the overall WIDTH of the Vault? (feet) 6

What is the overall DEPTH of the vault? (feet) 7

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.12.2.1.AccessCovers

Access Covers

Access Cover Type Hatch

Access Cover Condition Good Condition

Photo 85 Photo 86 Photo 87

1.1.12.2.2.InternalAssessment

1.1.12.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 15-25% Full

What type of Material is present?

Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

What percentage of organics is present? 96 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? No 1.1.12.2.2.2.ChamberInformation

Chamber Information 1.1.12.2.2.2.1.ChamberInformation1

Chamber Information 1

Chamber # or Description 1

Chamber Length 4

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 34

Depth of Sediment (bottom of vault to top of sediment) (inches) 12

Photo 88

1.1.12.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Trash / Debris Material Standard Trash (cups, bags, etc.) Organics (Leaves, sticks, etc.) Standard Hydrocarbons

Water Depth (top of water to sediment) (inches) 42

Depth of Sediment (bottom of vault to top of sediment) (inches) 4

Photo 89

1.1.12.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 42

Depth of Sediment (bottom of vault to top of sediment) (inches) 0

Photo 90

1.1.13.BMPInspection13

BMP Inspection 13

Unit ID or Number CC1SD16

Photo 91 Photo 92

1.1.13.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) No Rigging Needed

Will Traffic Control assistance be required? No 1.1.13.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Detention / Storage

Type of Detention System Concrete Structure

Detention System Type Other

Howmany access points are available 2

Access Cover Type Manhole

Photo 93 Photo 94

System Depth (feet) 15

Number of Modules / Systems 1

Is trash present in system? No

Is water present in the system? Yes

Water depth (top of water to sediment) (inches) 12

Is sediment present in system? No

Photo 95 Photo 96 Photo 97 Photo 98 Photo 99

1.1.14.BMPInspection14

BMP Inspection 14

Unit ID or Number CC1SD15

Photo 100

1.1.14.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) No Rigging Needed 1.1.14.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Detention / Storage

Type of Detention System Concrete Structure

Detention System Type Other

Howmany access points are available 3

Access Cover Type Manhole

Photo 101 Photo 102 Photo 103

System Depth (feet) 15

Number of Modules / Systems 3

Water depth (top of water to sediment) (inches) 41

Is sediment present in system? No

Photo 104 Photo 105 Photo 106

1.1.15.BMPInspection15

BMP Inspection 15

Unit ID or Number TRSD43

Photo 107

1.1.15.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft 1.1.15.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Other

System Type and Description Stormceptor

Is trash present in system? No

Is water present in the system? Yes

Water depth (top of water to sediment) (inches) 32

Is sediment present in system? Yes

Sediment depth (inches) 12

Photo 108 Photo 109 Photo 110

1.1.16.BMPInspection16

BMP Inspection 16

Unit ID or Number Cssd54

Photo 111

1.1.16.1.RiggingDetails

Is there a safe place to park our cleaning equipment? Yes

Rigging Distance to Unit (feet) 10 - 125 ft 1.1.16.2.InspectionDetails

Inspection Details

Is the system accessible for inspection? Yes

System Type Vault or Tank

What is the overall LENGTH of the vault? (feet) 12

What is the overall WIDTH of the Vault? (feet) 6

What is the overall DEPTH of the vault? (feet) 8

What is the Treatment Category for the system? HDS

Product Oldcastle NSBB

What is the NSBB Model NSBB-612 1.1.16.2.1.AccessCovers

Access Covers

Access Cover Type Manhole

Photo 112 Photo 113 Photo 114

1.1.16.2.2.InternalAssessment

1.1.16.2.2.1.Components

Components

Does this unit have Sungate's installed? No

Is the trash rack present? Yes

What is the condition of the trash rack? No Visible Damage

Are floatable materials present in trash rack? Yes

How full is the trash rack 0-15% Full

What type of Material is present? Organics (Leaves, sticks, etc.)

What percentage of organics is present? 100 From 1 to 100

Does this unit have a floating skimmer? Yes

Is there any visible damage to the skimmer? No

Does this system require a stormboom? No

Is an Upflow filter present? Yes

Photo 115

1.1.16.2.2.2.ChamberInformation

1.1.16.2.2.2.1.ChamberInformation1

Chamber Information 1

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 41

Depth of Sediment (bottom of vault to top of sediment) (inches) 8

Photo 116

1.1.16.2.2.2.2.ChamberInformation2

Chamber # or Description 2

Chamber Length 4

Trash / Debris Material Organics (Leaves, sticks, etc.)

Water Depth (top of water to sediment) (inches) 41

Depth of Sediment (bottom of vault to top of sediment) (inches) 2

Photo 117

1.1.16.2.2.2.3.ChamberInformation3

Chamber # or Description 3

Chamber Length 4

Trash / Debris Material None

Water Depth (top of water to sediment) (inches) 4

Photo 118 Photo 119

2.InspectorInformation

Inspector Information

Inspector Name Aaron Kimmell

Inspector Signature

20.03.2025 13:34 EDT

3.Mediasummary

Media summary

Photo 1 Photo 2

Photo 3 Photo 4

Photo 5 Photo 6

Photo 7 Photo 8

Photo 9 Photo 10

Photo 11 Photo 12

Photo 13 Photo 14

Photo 15 Photo 16

Photo 17 Photo 18

Photo 19 Photo 20

Photo 21 Photo 22

Photo 23 Photo 24

Photo 25 Photo 26

Photo 27 Photo 28

Photo 29 Photo 30

Photo 31 Photo 32

Photo 33 Photo 34

Photo 35 Photo 36

Photo 37 Photo 38

Photo 39 Photo 40

Photo 41 Photo 42

Photo 43 Photo 44

Photo 45 Photo 46

Photo 47 Photo 48

Photo 49 Photo 50

Photo 51 Photo 52

Photo 53 Photo 54

Photo 55 Photo 56

Photo 57 Photo 58

Photo 59 Photo 60

Photo 61 Photo 62

Photo 63 Photo 64

Photo 65 Photo 66

Photo 67 Photo 68

Photo 69 Photo 70

Photo 71 Photo 72

Photo 73 Photo 74

Photo 75 Photo 76

Photo 77 Photo 78

Photo 79 Photo 80

Photo 81 Photo 82

Photo 83 Photo 84

Photo 85 Photo 86

Photo 87 Photo 88

Photo 89 Photo 90

Photo 91 Photo 92

Photo 93 Photo 94

Photo 95 Photo 96

Photo 97 Photo 98

Photo 99 Photo 100

Photo 101 Photo 102

Photo 103 Photo 104

Photo 105 Photo 106

Photo 107 Photo 108

Photo 109 Photo 110

Photo 111 Photo 112

Photo 113 Photo 114

Photo 115 Photo 116

Photo 117 Photo 118

Photo 119

1. Inspection Details
1.1. BMP Inspection
1.1.1. BMP Inspection 1
1.1.1.1. Rigging Details
1.1.1.2. Inspection Details
1.1.1.2.1. Access Covers
1.1.1.2.2. Internal Assessment
1.1.1.2.2.1. Components
1.1.1.2.2.2. Chamber Information
1.1.1.2.2.2.1. Chamber Information 1
1.1.1.2.2.2.2. Chamber Information 2
1.1.1.2.2.2.3. Chamber Information 3
1.1.2. BMP Inspection 2
1.1.2.1. Rigging Details
1.1.2.2. Inspection Details
1.1.2.2.1. Access Covers
1.1.2.2.2. Internal Assessment
1.1.2.2.2.1. Components
1.1.2.2.2.2. Chamber Information
1.1.2.2.2.2.1. Chamber Information 1
1.1.2.2.2.2.2. Chamber Information 2
1.1.2.2.2.2.3. Chamber Information 3
1.1.3. BMP Inspection 3
1.1.3.1. Rigging Details
1.1.3.2. Inspection Details
1.1.3.2.1. Access Covers
1.1.3.2.2. Internal Assessment
1.1.3.2.2.1. Components
1.1.3.2.2.2. Chamber Information
1.1.3.2.2.2.1. Chamber Information 1
1.1.3.2.2.2.2. Chamber Information 2
1.1.3.2.2.2.3. Chamber Information 3
1.1.4. BMP Inspection 4
1.1.4.1. Rigging Details
1.1.4.2. Inspection Details
1.1.4.2.1. Access Covers
1.1.4.2.2. Internal Assessment
1.1.4.2.2.1. Components
1.1.4.2.2.2. Chamber Information
1.1.4.2.2.2.1. Chamber Information 1
1.1.4.2.2.2.2. Chamber Information 2
1.1.4.2.2.2.3. Chamber Information 3
1.1.5. BMP Inspection 5
1.1.5.1. Rigging Details
1.1.5.2. Inspection Details
1.1.6. BMP Inspection 6
1.1.6.1. Rigging Details
1.1.6.2. Inspection Details
1.1.6.2.1. Access Covers
1.1.6.2.2. Internal Assessment
1.1.6.2.2.1. Components
1.1.6.2.2.2. Chamber Information
1.1.6.2.2.2.1. Chamber Information 1
1.1.6.2.2.2.2. Chamber Information 2
1.1.6.2.2.2.3. Chamber Information 3
1.1.7. BMP Inspection 7
1.1.7.1. Rigging Details
1.1.7.2. Inspection Details
1.1.8. BMP Inspection 8
1.1.8.1. Rigging Details
1.1.8.2. Inspection Details
1.1.9. BMP Inspection 9
1.1.9.1. Rigging Details
1.1.9.2. Inspection Details
1.1.9.2.1. Access Covers
1.1.9.2.2. Internal Assessment
1.1.9.2.2.1. Components
1.1.9.2.2.2. Chamber Information
1.1.9.2.2.2.1. Chamber Information 1
1.1.9.2.2.2.2. Chamber Information 2
1.1.9.2.2.2.3. Chamber Information 3
1.1.10. BMP Inspection 10
1.1.10.1. Rigging Details
1.1.10.2. Inspection Details
1.1.11. BMP Inspection 11
1.1.11.1. Rigging Details
1.1.11.2. Inspection Details
1.1.11.2.1. Access Covers
1.1.11.2.2. Internal Assessment
1.1.11.2.2.1. Components
1.1.11.2.2.2. Chamber Information
1.1.11.2.2.2.1. Chamber Information 1
1.1.12. BMP Inspection 12
1.1.12.1. Rigging Details
1.1.12.2. Inspection Details
1.1.12.2.1. Access Covers
1.1.12.2.2. Internal Assessment
1.1.12.2.2.1. Components
1.1.12.2.2.2. Chamber Information
1.1.12.2.2.2.1. Chamber Information 1
1.1.12.2.2.2.2. Chamber Information 2
1.1.12.2.2.2.3. Chamber Information 3
1.1.13. BMP Inspection 13
1.1.13.1. Rigging Details
1.1.13.2. Inspection Details
1.1.14. BMP Inspection 14
1.1.14.1. Rigging Details
1.1.14.2. Inspection Details
1.1.15. BMP Inspection 15
1.1.15.1. Rigging Details
1.1.15.2. Inspection Details
1.1.16. BMP Inspection 16
1.1.16.1. Rigging Details
1.1.16.2. Inspection Details
1.1.16.2.1. Access Covers
1.1.16.2.2. Internal Assessment
1.1.16.2.2.1. Components
1.1.16.2.2.2. Chamber Information
1.1.16.2.2.2.1. Chamber Information 1
1.1.16.2.2.2.2. Chamber Information 2
1.1.16.2.2.2.3. Chamber Information 3
2. Inspector Information
3. Media summary

File details come from the government source that posted it. Updated .