26231 Ottawa Bldg - SIGMA Move to First Floor - Drawings.pdf
PDF 8 MB Posted
- Solicitation number
- RFQ 171 260000000470 2
- Issued by
- Grand Traverse County, Lansing City, Michigan
About this file
Document Summary
This is a comprehensive architectural and engineering drawing set for the State of Michigan Department of Technology, Management and Budget (DTMB) involving the relocation of the SIGMA department to the first floor of the Ottawa Building located at 611 W. Ottawa Street, Lansing, Michigan 48933. The project encompasses renovation of approximately 14,787 square feet on the first floor of the existing 171,360-square-foot building. The scope of work includes selective demolition of existing walls, mechanical systems, and finishes; construction of new interior walls and partitions; installation of new HVAC systems with VAV boxes and DDC controls; new electrical and fire protection systems; and comprehensive interior finishes including carpet, resilient flooring, paint, and ceiling systems. The project is designed to accommodate 99 occupants across multiple office types including open offices, individual offices, and various conference rooms of different sizes. The drawings were issued for bid and permit on September 18, 2026, following 50%, 90%, and 100% design review phases completed between August 13 and September 16, 2026.
The project requires compliance with the 2021 Michigan Building, Rehabilitation, Mechanical, and Energy Conservation Codes (based on 2021 I-Codes), 2021 Michigan Plumbing Code, 2023 National Electrical Code, and Michigan Construction Code Part 8 Electrical Code Rules. The design team includes Colliers Engineering & Design as architect and engineer, with key contacts including David Moss, AIA (Architect), Matt Hollenbeck, PE (Mechanical Engineer), and Angela Robinson, PE (Electrical Engineer). The contractor position is listed as TBD. Specific mechanical work includes installation of four new variable air volume (VAV) boxes with electric heating coils and controls integration with the existing building automation system, replacement of multiple diffuser units, and relocation of existing temperature sensors. The project requires full coordination among trades for demolition, protection of existing systems to remain, and final commissioning of all mechanical, electrical, and plumbing systems.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING INDEX - WITH SCHEDULED RELEASES
/1
/2
IS
S U
E D
F O
R
R E
V
IE
W
/3
/2
IS
S U
E D
F O
R
R E
V
IE
W
/1
/2
IS
S U
E D
F O
R
R E
V
IE
W
/1
/2
IS
S
U E
D F
O R
B
ID
/P E
R M
IT
00 - GENERAL
G000 COVER SHEET X X X X
G001 CODE COMPLIANCE & LIFE SAFETY PLANS X X X X
04 - ARCHITECTURAL
A001 GENERAL NOTES AND LEGENDS X X X X
A002 WALL TYPES X X X X
AD101 FIRST FLOOR DEMOLITION PLAN X X X X
AD121 FIRST FLOOR DEMOLITION CEILING PLAN X X X X
A101 FIRST FLOOR PLAN X X X X
A121 FIRST FLOOR CEILING PLAN X X X X
A141 FIRST FLOOR FINISH PLAN X X X X
A161 FIRST FLOOR FFE PLAN X X X X
A421 INTERIOR ELEVATIONS X X X X
A602 SCHEDULES, DOOR AND WINDOW DETAILS X X X X
05 - MECHANICAL
M000 MECHANICAL LEGEND SHEET
MD101 HVAC DEMOLITION PLAN
M101 1ST FLOOR HVAC PLAN
M401 ENLARGED HVAC PLANS
M500 MECHANICAL DETAILS
M600 HVAC SCHEDULES
07 - FIRE PROTECTION
F000 FIRE PROTECTION LEGEND SHEET
F101 LEVEL 1 FIRE PROTECTION PLAN
08 - ELECTRICAL
E001 LEGEND
ED101 ELECTRICAL POWER DEMOLITION PLAN
ED201 ELECTRICAL LIGHTING DEMOLITION PLAN
E101 POWER PLAN
E201 LIGHTING PLAN
E801 SCHEDULES
PROTECT YOURSELF
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
Know what's below.
Call before you dig.
www.colliersengineering.com
LANSING
7050 West Saginaw Hwy Suite 200 // Lansing, MI 48917
Phone: 517.272.9835
Colliers Engineering
& Design
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
M
A
O
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
Copyright © 2025. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of
Colliers Engineering & Design.
DRAWING INDEXPROJECT CONTACT LIST
PROJECT LOCATION MAP
OWNER:
STATE OF MICHIGAN, DTMB
3111 W ST JOSEPH ST, LANSING, MI
48917
CONTACT: ALAN GOSCHKA, AIA
PHONE: 517-388-3489
GOSCHKAA@MICHIGAN.GOV
ARCHITECT:
COLLIERS ENGINEERING & DESIGN
7050 W SAGINAW HIGHWAY, SUITE
200, LANSING, MI 48917
CONTACT: DAVID MOSS, AIA
PHONE: 517-898-1604
DAVID.MOSS@COLLIERSENG.COM
CONTRACTOR:
TBD
MECHANICAL ENGINEER:
COLLIERS ENGINEERING & DESIGN
3410 BRIARFIELD BLVD, MAUMEE,
OH 43537
CONTACT: MATT HOLLENBECK, PE
PHONE: 567-804-5118
MATT.HOLLENBECK@COLLIERSENG.COM
ELECTRICAL ENGINEER:
COLLIERS ENGINEERING & DESIGN
7050 W SAGINAW HIGHWAY, SUITE
200, LANSING, MI 48917
CONTACT: ANGELA ROBINSON, PE
PHONE: 517-827-8726
ANGELA.ROBINSON@COLLIERSENG.COM
G000
09/18/2026
OTTAWA BUILDING -
SIGMA MOVE TO 1ST
FLOOR
611 W. OTTAWA
STREET, LANSING,
MI 48933
MICHIGAN DTMB
W OTTAWA ST
W ALLEGAN ST
N P
IN
E
S T
S P
IN
E
S T
W IONIA ST
N B
U T
L E
R B
L V
D S
B U
T L
E R
B L V
D
N W
A L
N U
T S
T S
W A
L N
U T
S T
PROJECT LOCATION
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
REV DATE DESCRIPTION
1 08/13/26 PHASE 500 REVIEW
2 08/31/2026 90% REVIEW SET
3 09/16/2026 100% REVIEW SET
4 09/18/2026 ISSUED FOR BID/PERMIT
FE
FE
T
COPY
AREA
RAPID
SHRED
BIN
UP
UP
UP
UP
UP
UP
FE
FE
OCCUPANCY GROUP
# OCCUPANTS
S.F.
LEGEND
EXIT SIGN
EXIT
COMMON PATH OF EGRESS DISTANCE
EXIT ACCESS TRAVEL DISTANCE
(ALONG STAIRWAY NOSING AT OPEN
STAIRWAYS)
FIRE EXTINGUISHER ON WALL BRACKET
FIRE EXTINGUISHER CABINET
1-HR RATED WALL
2-HR RATED WALL
1-HR. RATED FLOOR/BEAM/COLUMN
TO SUPPORT RATED ELEVATOR
SHAFT & MACHINE ROOM ENCLOSURE
DF DRINKING FOUNTAIN
SS SERVICE SINK
SIGN DIRECTION
FACE OF SIGN
EATD
CPET
3-HR RATED WALL
4-HR RATED WALL
A
BCDEFGHJ
B
14,787 SF
DISTANCE 164' - 6"
DISTANCE 112' - 8"
DISTANCE 102' - 9"
FE FE
FE
FE
FE
REHABILITATION OF EXISTING STRUCTURES:
REPAIRS
PER THE 2015 MICHIGAN RAHABILITATION CODE FOR EXISTING BUILDINGS (2015 EIBC)
ALTERATIONS - LEVEL 1
CHANGE OF OCCUPANCY
FORMER OCCUPANCY CLASSIFICATION(S):
NEW OCCUPANCY CLASSIFICATION(S):
PARTIAL CHANGE OF OCCUPANCY: YES NO
ADDITIONS
IF YES: SEPARATED NOT SEPARATED
ALTERATIONS - LEVEL 2
ALTERATIONS - LEVEL 3
SEPARATED ADDITION: YES NO
IF YES, FIRE RESISTENCE RATING:
HISTORIC BUILDING
(CHAPTER 6)
(CHAPTER 7)
(CHAPTER 8)
(CHAPTER 9)
(CHAPTER 10)
(CHAPTER 11)
(CHAPTER 12)
RELOCATED BUILDING (CHAPTER 13)
ACCESSIBILITY UPGRADES: COMPLY WITH
SECTION 410 AND ADDENDA
FIRE WALL
FIRE BARRIER
HR
HR
X
SINGLE
MIXED OCCUPANCY
IF SEPARATED, FIRE RESISTANCE RATING OF FIRE BARRIER:
OCCUPANCY CLASSIFICATION(S):
USES:
HR
(CHAPTERS 3 & 5)
(TABLE 508.4)
SEPARATED COMBINATIONNON-SEPARATED
OCCUPANCY CLASSIFICATION AND MIXED OCCUPANCIES:
ACCESSORY - GROUP ; % OF FLOOR AREA
OFFICE, CONFERENCE
B - BUSINESS
X
X
AUTOMATIC SPRINKLER SYSTEM PROVIDED THROUGHOUT BUILDING:
YES
13R
NO
13NFPA STANDARD:
PARTIAL/LIMITED-AREA SPRINKLER SYSTEM:
YES NO
ALT. FIRE PROTECTION SYSTEM:
X
X
X
FIRE PROTECTION SYSTEMS:
SIZE AND LOCATION OF FIRE AREAS INDICATED ON CODE COMPLIANCE DRAWING(S)
FIRE PROTECTION SYSTEM REQUIRED PROVIDED SECTION
AUTOMATIC SPRINKLER
ALT. AUTOMATIC FIRE-EXTINGUISHING SYST
STANDPIPE
PORTABLE FIRE EXTINGUISHER
FIRE ALARM & DETECTION
EMERGENCY ALARM
SMOKE CONTROL SYSTEM
SMOKE & HEAT REMOVAL
(903)
(904)
(905)
(906)
(907)
(908)
(909)
(910)
FIRE COMMAND CENTER (911)
(CHAPTER 9)
FIRE DEPARTMENT CONNECTIONS (912)
FIRE PUMP (913)
EMERGENCY RESPONDER SAFETY (914)
CARBON MONOXIDE DETECTION (915)
EMERGENCY RESPONDER RADIO (916)
YES
NO
YES
YES
YES
YES
NO
NO
YES
NO
YES
YES
YES
YES
NO
NO
NO NO
NO NO
NO NO
NO NO
NO NO
NO NO
MEANS OF EGRESS:
DESIGN OCCUPANT LOAD SUMMARY
(CHAPTER 10)
MEANS OF EGRESS ELEMENT REQUIRED PROVIDED SECTION
NUMBER OF EXITS
EXIT ACCESS TRAVEL DISTANCE
DEAD-END LIMIT
COMMON PATH OF TRAVEL LIMIT
(1006.3.2)
(TABLE 1017.2)
(1020.4)
(1006.2.1)
FIRST FLOOR
CORRIDOR FIRE-RESIST. RATING (TABLE 1020.1)
OCCUPANCY
TOTAL
2 3
300 FT. MAX. 164' - 6"
50 FT. MAX. COMPLIES
100 FT. MAX. COMPLIES
B
BUILDING CODE SUMMARY
PROJECT NAME:
PROJECT INFORMATION:
PROJECT NUMBER:
PREPARED BY:
DATE:
CHECKED BY:
DATE:
APPLICABLE CODE:
COMPLIANCE WITH THE: 2021 MICHIGAN BUILDING, REHABILITATION, MECHANICAL, AND ENERGY CONSERVATION CODES (BASED ON 2021 I-CODES), 2021 PLUMBING CODE (BASED ON 2018 IPC) INCLUDING MICHIGAN ADDENDA AND ERRATA; 2023 NATIONAL ELECTRICAL CODE (NEC) AND 2023 CONSTRUCTION CODE - PART 8 ELECTRICAL CODE RULES; BOILER CODE (2010 ASME BOILER AND PRESSURE VESSEL CODES WITH 2011 ADDENDA); ELEVATOR CODE (2010 ASME 17.1, 2011 ASME A18.1 AND ELEVATOR SAFETY BOARD GENERAL RULES, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC A117.1-09), AND OTHER LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS APPLICABLE TO THIS PROJECT.
OTTAWA BUILDING - SIGMA MOVE TO FIRST FLOOR
26008532A
ADDITIONAL NOTES:
COMPLIANCE:
A. PROVIDE FIRE EXTINGUISHERS IN CONFORMANCE WITH THE INTERNATIONAL FIRE
CODE SECTION 906 AND COORDINATE WITH FIRE MARSHAL PRIOR TO INSTALLATION.
DO NOT INSTALL FIRE EXTINGUISHERS UNTIL LOCATIONS HAVE BEEN REVIEWED AND
APPROVED BY THE AUTHORITY HAVING JURISDICTION.
B. OBTAIN ALL REQUIRED PERMITS AND PAYMENT OF PERMIT AND APPLICATION FEES
FOR THE WORK.
CERTIFICATIONS:
A. THE ARCHITECTS CERTIFICATION IS ONLY FOR THE WORK SHOWN TO BE DONE. IT
DOES NOT CONSTITUTE APPROVAL OF PRE-EXISTING CONDITIONS OR REVIEW OF
THOSE CONDITIONS FOR CODE COMPLIANCE.
B. THE ARCHITECTS CERTIFICATION IS FOR COMPLIANCE WITH THE BUILDING CODE OF
MICHIGAN AND IT'S VARIOUS REFERENCE STANDARDS, FOR PURPOSES OF OBTAINING
A BUILDING PERMIT THROUGH THE AUTHORITY HAVING JURISDICTION AND TO CONVEY
CONSTRUCTION REQUIREMENTS FOR THE PROJECT. CERTIFICATION DOES NOT
GUARANTEE COMPLIANCE WITH LOCAL CODES THAT MAT APPLY.
HEIGHT & AREA - ACTUAL:
BUILDING HEIGHT HEIGHT IN FEET HEIGHT IN STORIES
EXISTING ft
BUILDING AREA EXISTING RENOVATION TOTAL
SUMMARY
FIRST 28,146 sf 14,787 sf 42,933 sf
SECOND 42,933 sf - sf 42,933 sf
THIRD 48,190 sf - sf 48,190 sf
FOURTH 52,091 sf - sf 52,091 sf
TOTAL 171,360 sf 14,787 sf 186,147 sf
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
G001
SCALE : 1/16" = 1'-0"
CODE COMPLIANCE DIAGRAM - FIRST FLOOR
8' - 0"
XX
CEILING HEIGHT
ELEVATION NOTATION
EQUIPMENT TAG
KEYNOTE (REMOVALS)
KEYNOTE
CAST STONE
GRAVEL OR CRUSHED STONE
CONCRETE
CONCRETE MASONRY UNIT
UNDISTURBED EARTH
BRICK
RIGID INSULATION
PLYWOOD
SAND OR GYPSUM BOARD
STEEL
WOOD FRAMING (CONTINUOUS) BATT INSULATION
WOOD BLOCKING (DISCONTIN.)
EXISTING FINISH WOOD
GENERAL ARCHITECTURAL SYMBOLS
MATERIAL INDICATORS
A101
A101
XXX
XXX
A101
SIM
1Ref
DETAIL CALLOUT
ELEVATION MARKER
DRAWING NO.
ELEVATION
NO.
BREAK MARKER
NORTH ARROW
(SHOWN IN KEYPLAN)
NEW COLUMN ID
DETAIL NO.
DRAWING NO.
EXISTING COLUMN ID
A101
1Ref
R e f
R e f
1Ref
A000
VIEW TITLE
DETAIL NO.
SECTION MARKER
SECTION NO.
DRAWING NO.
DETAIL SECTION
DRAWING NO.
ACCESSORY MARKER
DETAIL NO.
XX
EXISTING DOOR
SCHEDULED DOOR
ROOM TAG
WINDOW TYPE MARKER
DOOR MARKER
Room name
WALL STYLES
EXISTING BRICK WALL
EXISTING CMU WALL
EXISTING STUD WALL
STUD WALL
CMU WALL
BRICK WALL
EXISTING WALL REMOVAL
GENERAL NOTE WITHOUT PROJECT MANUAL
ALL GENERAL NOTES PERTAIN TO ALL ARCHITECTURAL (A-SERIES) DRAWINGS IN THIS SET
GENERAL
1. DEFINITIONS: “PROVIDE” MEANS FURNISH AND INSTALL. SUPPLY LABOR AND MATERIALS TO RESULT IN A FINISHED AND/OR OPERABLE SYSTEM.
2. CONTRACTOR RESPONSIBILITIES:
A. MATERIALS, CONSTRUCTION METHODS INCLUDING BUT NOT LIMITED TO LAYOUT, COORDINATION, SCHEDULE AND CONSTRUCTION SITE ACCESS AND WORK.
B. DAILY CLEANING: KEEP SITE FREE FROM WASTE, RUBBISH, AND DEBRIS. REMOVE DAILY. WHEN WORK IS COMPLETE, LEAVE THE PREMISES BROOM CLEAN AND CLEAN FINISHED
SURFACES, FIXTURES, GLASS, STOREFRONT, ETC.
C. FINAL CLEANING, PRIOR TO PUNCHLIST INSPECTION BROOM CLEAN ALL HARD SURFACE FLOORS, VACUUM ALL CARPETING AND WIPE DOWN ALL HORIZONTAL AND GLASS
SURFACES PROVIDING A DUST FREE SURFACE.
D. TEMPORARY PROTECTION IS REQUIRED TO MAINTAIN ONGOING BUILDING OPERATIONS, EXITING PATHS, DUST CONTROL AND OCCUPANT SAFETY. IDENTIFY THE REQUIREMENTS FOR TEMPORARY PROTECTION AND PROJECT PHASING. COORDINATE WITH OWNER FOR OTHER REQUIREMENTS.
E. COORDINATE STARTUP AND ADJUSTING OF EQUIPMENT AND OPERATING COMPONENTS. START EQUIPMENT AND OPERATING COMPONENTS AND TEST TO CONFIRM PROPER OPERATION AND CONTROL. REMOVE MALFUNCTIONING UNITS, REPLACE WITH NEW UNITS, AND RETEST.
F. CLOSEOUT DOCUMENTS, CERTIFICATE OF RELEASE FROM THE AUTHORITY OF JURISDICTION AND INSURANCE FOR CONTINUING COVERAGE, WARRANTIES, TEST & INSPECTION
RESULTS AND OPERATION, EMERGENCY & MAINTENANCE MANUALS.
3. EXISTING CONDITIONS: REVIEW EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING WORK AND REPORT DISCREPANCIES TO THE ARCHITECT IMMEDIATELY.
4. CONTRACT DOCUMENTS:
A. PLANS, ELEVATIONS, SECTIONS, DETAILS AND SCHEDULES ARE COMPLEMENTARY. PLAN DRAWINGS WILL TAKE PRECEDENCE OVER ELEVATION, SECTION AND DETAILS DRAWINGS
IN ANY CONFLICTS OF HORIZONTAL DIMENSIONS. DETAIL PLAN DRAWINGS WILL TAKE PRECEDENCE OVER LARGER SCALE PLANS IN ANY CONFLICTS WITH HORIZONTAL DIMENSIONS. WALL AND BUILDING SECTIONS WILL TAKE PRECEDENCE OVER PLAN DRAWING AND DETAILS IN ANY CONFLICTS WITH VERTICAL DIMENSIONS. DETAILS AND WALL SECTIONS WILL TAKE PRECEDENCE OVER ELEVATION AND PLAN DRAWINGS IN ANY CONFLICTS WITH MATERIAL DESCRIPTION. SCHEDULES WILL TAKE PRECEDENCE OVER OTHER ARCHITECTURAL DRAWINGS IN AND CONFLICTS WITH WALL, FLOOR AND CEILING FINISHES AND DOOR, DOOR HARDWARE AND FENESTRATION INFORMATION.
B. DRAWINGS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT AND, UNLESS OTHERWISE PROVIDED, BERGMANN SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE
COPYRIGHT.
C. WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE LATEST EDITION AND/OR ADDENDUM.
FIELD CONDITIONS
1. REPAIR: EXISTING SURFACES TO REMAIN IMPACTED BY DEMOLITION TO MATCH EXISTING ADJACENT SURFACES.
2. DISCREPANCIES: NOTIFY ARCHITECT OF EXISTING DAMAGED OR DETERIORATED BUILDING ELEMENTS REVEALED DURING DEMOLITION OR CONSTRUCTION PRIOR TO PROCEEDING
WITH ADDITIONAL WORK IN THE AREA.
3. HAZARDOUS MATERIALS: THERMAL SYSTEM INSULATIONS AND SURFACING MATERIALS FOUND IN BUILDINGS CONSTRUCTED NO LATER THAN 1980 SHALL BE CONSIDERED PRESUMED ASBESTOS CONTAINING MATERIALS (PACM) UNLESS PROVEN OTHERWISE BY APPROPRIATE BULK SAMPLING AND LABORATORY ANALYSIS CONDUCTED BY APPROVED LICENSED PERSONNEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH ALL REGULATIONS. THE LANDLORD SHALL PROVIDE COPIES OF ANY ASBESTOS SURVEYS THEY HAVE ON FILE
AT THE REQUEST OF THE CONTRACTOR.
4. SAFETY: FOLLOW THE OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION (OSHA) 29 CFR 1926.62, LEAD EXPOSURE IN CONSTRUCTION REGULATION. MATERIALS HAVING A CONCENTRATION EQUAL OR GREATER THAN 0.5% BY WEIGHT IN LEAD ARE CONSIDERED TO BE LEAD BASED. HOWEVER, OSHA CONSIDERS ANY AMOUNT OF LEAD ENCOUNTERED DURING CONSTRUCTION TO BE OF CONCERN. THE REGULATION STATES THAT THE EMPLOYER SHALL ASSURE THAT NO EMPLOYEE IS EXPOSED TO LEAD AT CONCENTRATIONS GREATER THAN FIFTY MICROGRAMS PER CUBIC METER OF AIR (50 MG/M^3) AVERAGED OVER AN 8-HOUR PERIOD. CONTRACTORS SHALL DETERMINE AND TAKE APPROPRIATE
MEASURES IF THEY SUSPECT THE PRESENCE OF LEAD.
FINISHES
A. GENERAL: FINISHED FLOORS EXTEND INTO TOE SPACES,UNDER CASEWORK ON LAB PROJECTS, CLOSETS, DOOR REVEALS AND SIMILAR OPENINGS.
B. PRODUCTS:
A. INSTALL MATERIALS USING MANUFACTURER'S APPROVED ADHESIVES AND METHODS, U.N.O.
B. PAINT DESIGNATIONS INDICATE COLOR ONLY, REFER TO SPECIFICATION FOR FINISH TYPE.
C. PROVIDE SELF LEVELING TROWELABLE UNDERLAYMENT WHERE REQUIRED TO OBTAIN FINISH MANUFACTURER'S REQUIRED SUBFLOOR CONDITION.
D. PROVIDE THE REQUIRED TRANSITIONS BASED ON TYPES IDENTIFIED ON DRAWINGS AT EACH FINISH TRANSITION LOCATION.
C. EXECUTION:
A. ADHERE TO MATERIAL OR SYSTEM MANUFACTURER’S WRITTEN INSTALLATION INSTRUCTIONS AND TOLERANCES. ANY VARIATIONS FROM WRITTEN INSTALLATION AND
INSTRUCTIONS MUST RECEIVE WRITTEN APPROVAL FROM THE MANUFACTURER AND MAINTAIN MANUFACTURER’S WARRANTIES.
B. PRIOR TO STARTING THE INSTALLATION OF A MATERIAL OR SYSTEM, VERIFY THE SUBSTRATE IS WITHIN THE MANUFACTURER’S REQUIRED TOLERANCES AND REQUIRED CLEARANCES ARE PROVIDED. NOTIFY THE CONSTRUCTION MANAGER OR GENERAL CONTRACTOR AND DEIGN PROFESSIONAL IN WRITING WHEN THE SUBSTRATE IS NOT WITHIN MANUFACTURER’S TOLERANCE OR REQUIRED CLEARANCES ARE NOT PROVIDED. PROCEEDING WITH INSTALLATION SIGNIFIES ACCEPTANCE OF THE SUBSTRATE AND
CLEARANCES.
C. PROVIDE MANUFACTURER’S REQUIRED ENVIRONMENTAL TESTS FOR MOISTURE, VAPOR DRIVE, RELATIVE HUMIDITY AND TEMPERATURE TO VERIFY THESE ARE WITHIN THE
MATERIAL MANUFACTURER’S TOLERANCE PRIOR TO INSTALLING MATERIALS.
D. MATERIAL AND INSTALLATION SHALL CONFORM WITH LOCAL, STATE AND NATIONAL BUILDING CODES AND CONSTRUCTION STANDARDS ENFORCED BY THE AUTHORITY HAVING
JURISDICTION.
E. REQUIRED DOCUMENTATION:
1. SAFETY DATA SHEETS.
2. PROVIDE SAMPLES WHEN SPECIFICALLY REQUESTED IN THESE DOCUMENTS.
3. PROVIDE SHOP DRAWINGS OF MATERIALS AND SYSTEMS, WHICH WILL BE BUILT INTO AND MUST BE COORDINATED WITH OTHER CONSTRUCTION. SHOP DRAWINGS SHALL
CONSIST OF PLAN, ELEVATION, SECTION VIEWS AND DETAILS AS REQUIRED TO COMMUNICATE FINAL APPEARANCE AND CONNECTION TO ADJOINING CONSTRUCTION.
F. PROTECT ADJACENT SURFACES DURING WORK.
G. REMOVE ADHESIVE OR PAINT SPOTS FROM FINISHED FLOORS, WALLS, GLASS OR OTHER SURFACES. FINISHES TO MEET OR EXCEED CODE REQUIREMENTS.
H. FILL MINOR DRYWALL IRREGULARITIES WITH SPACKLING COMPOUND AND SAND TO A SMOOTH LEVEL SURFACE. EXERCISE CARE TO AVOID RAISING THE NAP OF PAPER.
I. DO NOT PERFORM PAINTING AND OTHER FINISHING WORK UNDER CONDITIONS UNSUITABLE FOR EXECUTION OF PAINTING WORK. AIR SHALL BE FREE FROM DUST AND DIRT TO PREVENT LODGING OF FOREIGN MATTER IN FRESH PAINT. FLOORS TO BE BROOM CLEAN BEFORE PAINTING IS STARTED.
J. EDGES OF PAINT ADJOINING OTHER COLORS OR MATERIALS TO BE SHARP AND CLEAN WITHOUT OVERLAP.
K. WHENEVER NECESSARY TO OBTAIN REQUIRED RESULTS, REFINISH AN ENTIRE WALL RATHER THAN SPOT FINISHING WHERE A PORTION OF THE FINISH HAS BEEN DAMAGED OR IS
UNSATISFACTORY.
L. WHEN INSTALLING CARPET FOLLOW THE CARPET AND RUG INSTITUTE METHODS OF INSTALLATION AND MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS.
M. WHEN INSTALLING TILE FOLLOW THE TILE COUNCIL OF NORTH AMERICA'S INSTALLATION SPECIFICATIONS AND MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS.
N. CENTER FLOOR MATERIAL TRANSITIONS ON DOOR ABOVE.
O. FLOOR MATERIAL TRANSITIONS SHALL OCCUR BELOW THE DOOR.
ENERGY CODE STATEMENT:
TO THE BEST OF THE REGISTERED DESIGN PROFESSIONAL’S KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS AND/OR SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 ENERGY CODE.
UNIFORM CODE STATEMENT:
TO THE BEST OF THE REGISTERED DESIGN PROFESSIONAL’S KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT, THESE PLANS AND/OR SPECIFICATIONS ARE IN COMPLIANCE WITH THE 2020 UNIFORM CODE.
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A001
WALLS
A. DIMENSIONS:
a. STUD WALLS ARE TO FACE OF STUD, UNLESS OTHERWISE INDICATED IN A.c. OR A.d. BELOW.
b. MASONRY WALLS ARE TO FACE OF MASONRY.
c. EXISTING CONSTRUCTION ARE TO FINISHED FACE OF CONSTRUCTION.
d. WHERE NOTED AS “CLR” DIMENSIONS ARE TO FINISHED SURFACE AND ARE CRITICAL FOR ACCESSIBILITY
REQUIREMENTS OR BUILT-IN FURNISHINGS.
B. TYPES:
a. WALLS NOT INDICATED WITH A WALL TYPE SHALL BE TYPE M30.
b. COLUMN ENCLOSURES, CHASES AND ENCLOSED UNINHABITABLE SPACES SHALL BE WALL TYPE M31, UNLESS NOTED
OTHERWISE.
c. BRACING: PROVIDE CHANNEL COLD ROLLED STEEL (CRSS) BRACING AT ALL METAL STUD WALLS. INSTALL TWO ROWS
OF BRACING 4'-0" O.C. FOR WALLS UP TO 13'-0" HIGH.
d. PROVIDE (2) #10-7/16" HEX HEAD SHEET METAL SCREWS AT EACH STUD/TRACK CONNECTION AT ALL WALLS, BULK
HEADS & SOFFITS NOT EXTENDING FLOOR TO DECK.
e. PROVIDE DEFLECTION TRACK OR CLIP AT TOP OF METAL STUD WALLS THAT EXTEND TO THE UNDERSIDE OF
STRUCTURAL MEMBERS OR FLOOR/ ROOF DECK.
f. METAL STUD WALLS IN WHICH STUDS DO NOT EXTEND TO DECK ABOVE SHALL BE LATERALLY BRACED AT 45 DEGREES TO THE STRUCTURE ABOVE WITH 3 5/8" x 20 GA. STUDS @ 48" O.C. MAX., AND AT ENDS OF SUCH WALLS WHICH DO NOT
INTERSECT OTHER WALLS.
g. PROVIDE FULL HEIGHT DOUBLE STUDS AT DOOR AND WINDOW JAMBS.
h. FIRE-RESISTANT JOINT SYSTEMS: AT FIRE-RESISTANT RATED WALLS, FLOORS OR FLOOR/CEILING ASSEMBLIES, AND ROOFS OR ROOF/CEILING ASSEMBLIES, PROVIDE AN APPROVED TESTED JOINT ASSEMBLY PROVIDING THE MINIMUM TIME AND TEMPERATURE RISE AT THE WALL, FLOOR, OR ROOF SUITABLE FOR THE CONSTRUCTION WHERE THE
SYSTEM IS TO BE INSTALLED.
i. THE BOTTOM EDGE OF GYPSUM WALL BOARD SHALL BE INSTALLED 3/8" ABOVE THE FLOOR AND SEALED AS NOTED IN
WALL TYPES.
C. RATINGS:
a. SMOKE WALLS AND SMOKE BARRIERS: SMOKE WALLS AND SMOKE BARRIERS MUST FORM A COMPLETE BARRIER TO
LIMIT THE TRANSFER OF SMOKE, INCLUDING PERIMETER DETAILS, PENETRATIONS, AND AS REQUIRED BETWEEN WALLS AND DOOR JAMBS, OR SIDELIGHT FRAMES. THE MEMBRANE IS TO BE CONTINUOUS THROUGH ALL CONCEALED
SPACES.
1. RECESSED CABINETS, OUTLET BOXES, AND OTHER PENETRATIONS MUST BE SEALED
2. OPENINGS AROUND PENETRATIONS ARE TO BE SEALED.
3. ALL EXPOSED JOINTS, ANGLES, AND ABUTMENTS IN THE SYSTEM, INCLUDING FLOOR AND ABOVE CEILING MUST BE
TAPED AND FINISHED.
4. SEAL THE INTERFACE BETWEEN WALLS AND DOOR JAMBS, OR SIDELIGHT FRAMES.
b. FIRE WALLS AND FIRE BARRIERS: FIRE WALLS AND FIRE BARRIERS MUST BE SIMILARLY CONSTRUCTED AS A COMPLETE BARRIER TO RESIST THE SPREAD OF SMOKE AND FIRE. PENETRATIONS MUST BE SEALED AND LABELED WITH AN APPROVED FIRE RESISTANT JOINT SYSTEM. INSTALL A FIRE RESISTANT JOINT SYSTEM AT THE HEAD AND
FLOOR CONDITION OF FIRE RATED WALLS AND BARRIERS.
c. FIRE AND SMOKE WALL / BARRIER / WALLS LABELING:
1. WHERE THERE IS AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING, OR ATTIC SPACE, FIRE WALLS, FIRE
BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH
SIGNS OR STENCILING IN THE CONCEALED SPACE. SUCH IDENTIFICATION SHALL:
A. BE LOCATED WITHIN 15 FEET (4572 MM) OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FEET (9144 MM) MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION.
B. INCLUDE LETTERING NOT LESS THAN 3 INCHES (76 MM) IN HEIGHT WITH A MINIMUM 3/8-INCH (9.5 MM) STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING, “FIRE AND/OR SMOKE BARRIER –
PROTECT ALL OPENEINGS,” OR OTHER WORDING.
d. ACOUSTICAL WALLS: WALLS INDICATED WITH ACOUSTICAL BATT, AND/OR A GIVEN AN STC RATING, SHALL BE
CONSTRUCTED TO MINIMIZE SOUND TRANSMISSION AS FOLLOWS:
1. PROVIDE ACOUSTICAL SEALANT AT ALL FLOOR AND HEAD LEVELS, EACH SIDE OF THE WALLS.
2. SET TRACK IN 3 CONTINUOUS BEADS OF ACOUSTICAL SEALANT.
3. EXTEND SOUND BATTS THOROUGH ANY INTERSECTING WALLS.
4. STAGGER OUTLETS A MINIMUM OF 24 INCHES HORIZONTAL. DO NOT INSTALL MORE THAN ONE OUTLET IN A
COMMON STUD CAVITY. SEAL JOINTS AROUND OUTLETS WITH ACOUSTICAL SEALANT.
D. GYPSUM BOARD WALL COMPONENTS AND ACCESSORIES:
a. WALL TYPES DO NOT INDICATE FINAL FINISHES. REFER TO FINISH PLANS AND FINISH SCHEDULE.
b. GYPSUM BOARD SHALL BE TYPE “X” FIRE RATED WITH:
1. LEVEL 1 FINISH AT JOINTS WHICH WILL REMAIN CONCEALED. PROVIDE GALVANIZED STEEL CORNER BEADS AT
CORNERS.
2. LEVEL 3 FINISH WHERE WALLS EXPOSED TO VIEW SCHEDULED FOR PAINT IN SERVICE SPACES (eg. TELE / DATA
CLOSETS, MECHANICAL ROOMS, JANITOR CLOSETS, STORAGE ROOMS).
3. LEVEL 4 FINISH WHERE EXPOSED TO VIEW UPON PROJECT COMPLETION U.N.O.
4. LEVEL 5 FINISH AT GRAPHIC CORRIDOR, AS WELL AS DRY ERASE AND CHALK BOARD PAINTED AREAS. REFER TO
FINISH LOCATION ON PLANS, AND COORDINATE WITH DESIGNER IN THE FIELD.
c. PROVIDE MOISTURE/ MOLD / ABUSE RESISTANT GYPSUM BOARD AT WALLS IN TOILET ROOMS, JANITORS CLOSETS AND
ANY ROOM WHERE MOISTURE CONDITIONS WILL OCCUR AND NOT RECEIVING TILE FINISH.
d. PROVIDE GLASS MATT GYPSUM BOARD AT WALLS DIRECTLY ADJACENT TO LIVING WALL ELEMENT AND AT ALL WET AREAS (SHOWER ROOMS, COMMUNAL KITCHEN/DISHWASHER, ETC.) GLASS MAT GYPSUM BOARD SHALL RECEIVE
FIBERGLASS TAPE AND FINISH AS RECOMMENDED BY MANUFACTURER.
e. METAL TRIM:
1. EXPOSED METAL J-TRIM TO BE COMPLETELY COVERED WITH SKIM COAT
2. NON-METALIC J-TRIM OR OTHER SHAPES ARE NOT ACCEPTABLE, UNLESS OTHERWISE NOTED
f. LOCATIONS WHERE GYPSUM BOARD WALLS TERMINATE AT DISSIMILAR MATERIALS, PROVIDE A FINISH-ABLE METAL END TRIM AND A 1/4" GAP BETWEEN TRIM AND ADJACENT MATERIAL. FILL GAP WITH BACKER ROD AND SEALANT.
g. PROVIDE SOLID FIRE TREATED WOOD BLOCKING IN WALL AND CEILING CONSTRUCTION AS REQUIRED TO SUPPORT WALL MOUNTED MILLWORK AND CASEWORK, FURNISHINGS, RAILINGS, GRAB BARS, TOILET & BATH ACCESSORIES OR
ANY OTHER WALL MOUNTED ITEMS INDICATED ON THESE DRAWINGS REQUIRING BLOCKING.
h. PROVIDE PAPER FACED "L" SHAPED TAPE ON TRIM AT THE TOP OF ALL GYP. BD. THAT ABUTS SUSPENDED CEILINGS
AND EXPOSED STRUCTURE.
E. CONTROL JOINTS:
a. PROVIDE IN GYPSUM WALL BOARD CONSTRUCTION AS FOLLOWS:
1. PROVIDE CONTROL JOINTS IN EXPANSES OF WALLS AT MAXIMUM 25-FOOT INTERVALS, AND FULL HEIGHT.
CONTROL JOINTS ARE RECOMMENDED AT DOOR JAMBS, EXTENDING FROM DOOR HEAD TO TOP OF WALL.
2. CONTROL JOINTS ARE REQUIRED IN CEILINGS TO LIMIT AREAS TO 2,500 SQUARE FEET. INSTALL CONTROL JOINTS IN CEILINGS TO LIMIT DIMENSIONS IN EITHER DIRECTION TO 50 FEET MAXIMUM WITH PERIMETER RELIEF, 30 FEET MAXIMUM OTHERWISE. INSTALL CONTROL JOINTS WHERE CEILING FRAMING OR FURRING CHANGES DIRECTION.
3. PROVIDE CONTROL JOINTS IN GYPSUM WALL BOARD WHERE THE UNDERLYING STRUCTURE CONTAINS A
CONTROL OR MOVEMENT JOINT.
4. IN AN ACOUSTICALLY RATED ASSEMBLY, PROVIDE ACOUSTICALLY TESTED CONTROL JOINT ASSEMBLY WITH A STC RATING MINIMALLY EQUAL TO THE WALLS STC RATING. COORDINATE REQUIRED LOCATIONS ON FEATURE WALLS WITH DESIGNER IN THE FIELD. METAL TRIM: EXPOSED METAL OR NON-METALLIC J-MOLD IS NOT ACCEPTABLE.
5. PROVIDE CONTROL JOINTS AT ALL BUILDING CONTROL OR EXPANSION JOINTS.
b. IN CONCRETE MASONRY UNIT WALLS REFER TO STRUCTURAL FOR CONTROL JOINT SPACING
c. IN CLAY MASONRY VENEERS REFER TO ARCHITECTURAL EXTERIOR ELEVATIONS FOR EXPANSION JOINT LOCATIONS
WALL TYPES
NOTE: SEE TYPICAL WALL SECTIONS FOR ADDITIONAL
INFORMATION AT FLOOR AND DECK ABOVE CONDITIONS.
3 5/8" 20 GA. (UON) MTL
STUDS @ 16" O.C.
ONE LAYER TYPE 'X'
5/8" TYPE 'X' GYP. BD.
EACH SIDE
M30
3-1/2" SOUND
ATTENUATION BATT
INSULATION
4 7/8"
3 5/8" 20 GA. (UON) MTL
STUDS @ 16" O.C.
ONE LAYER TYPE 'X'
5/8" TYPE 'X' GYP. BD.
M31
4 1/4"
WALL MATERIAL - SEE BELOW
WALL SIZE - SEE BELOW
WALL TYPE - 0, 1, 2, 3 ETC.
WALL MATERIAL WALL SIZES
WALL INFORMATION
M = METAL STUD 1 = 1-5/8" METAL STUDS @ 16" O.C.
2 = 2-1/2" METAL STUDS @ 16" O.C.
3 = 3-5/8" METAL STUDS @ 16" O.C.
6 = 6" METAL STUDS @ 16" O.C.
WALL INFORMATION
1 = WALL HEIGHT STUD FRAMING AND GYP BOARD FINISH TO EXISTING CEILING ABOVE
2 = GYP BOARD FINISH TO 10'-6" ABOVE FINISHED FLOOR
3 = 3-1/2" SOUND ATTENUATION CAVITY BATT INSULATION FULL HEIGHT, FLOOR TO
EXISTING CEILING ABOVEREF WALL TYPES AND
DETAILS; SEE THIS SHEET
WALL LEGEND
COLUMN ENCLOSURES, CHASES AND ENCLOSED UNINHABITABLE SPACES ARE
TO BE WALL TYPE M31, UNLESS NOTED OTHERWISE.
M60
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A002
UP
UP
UP
UP
DEFGHJ
1 3
NOT IN SCOPE
A. CONTRACTOR SHALL COORDINATE REMOVAL OF FLOORS, WALLS
AND CEILINGS WITH MECHANICAL, ELECTRICAL AND PLUMBING
TRADES. ALL POWER, MECHANICAL AND PLUMBING LINES SHALL BE
REMOVED BACK TO NEAREST MAIN BRANCH LINE OR PANEL.
B. CONTRACTOR SHALL PROTECT EXISTING CONSTRUCTION AND
EQUIPMENT NOTED TO REMAIN FROM DAMAGE RESULTING FROM
DEMOLITION ACTIVITIES. ANY DAMAGE TO EXISTING PROPERTY
RESULTING FROM DEMOLITION SHALL BE REPAIRED IMMEDIATELY AT
THE CONTRACTOR'S EXPENSE.
C. CONTRACTOR SHALL PROTECT ADJACENT SURFACES IN
PREPARATION OF SAW CUTTING REQUIRED FOR DEMOLITION
ACTIVITIES.
GENERAL NOTES
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
AD101
SCALE : 3/32" = 1'-0"
PARTIAL FIRST FLOOR DEMOLITION PLAN
1 REMOVE EXISTING METAL STUD WALL INCLUDING FLOOR AND WALL
EMBEDS.
2 REMOVE HOLLOW METAL DOOR, FRAME AND HARDWARE. SALVAGE AND
TURN OVER TO STATE.
3 REMOVE HOLLOW METAL DOOR, SIDELIGHT, FRAME AND HARDWARE.
SALVAGE AND TURN OVER TO STATE.
4 REMOVE EXISTING RECESSED FIRE EXTINGUISHER CABINET. SALVAGE FOR
REUSE.
5 REMOVE EXISTING FLOORING AND BASE.
6 PATCH AFFECTED WALLS FROM THERMOSTAT REMOVAL.
7 DEMO EXISTING GYP. BRD. FOR WOOD BACKING INSTALLATION. SEE
ELEVATIONS FOR LOCATION OF BACKING.
KEYNOTES #
KEY PLAN
TS
TS
T
DEFGHJ
NOT IN SCOPE
2 2
2 2
2 2
2 2
2 2
2 4 4
2 4 4
2 2 2
1'
- 6
/4
A. CONTRACTOR SHALL COORDINATE REMOVAL OF FLOORS, WALLS
AND CEILINGS WITH MECHANICAL, ELECTRICAL AND PLUMBING
TRADES. ALL POWER, MECHANICAL AND PLUMBING LINES SHALL BE
REMOVED BACK TO NEAREST MAIN BRANCH LINE OR PANEL.
B. CONTRACTOR SHALL PROTECT EXISTING CONSTRUCTION AND
EQUIPMENT NOTED TO REMAIN FROM DAMAGE RESULTING FROM
DEMOLITION ACTIVITIES. ANY DAMAGE TO EXISTING PROPERTY
RESULTING FROM DEMOLITION SHALL BE REPAIRED IMMEDIATELY AT
THE CONTRACTOR'S EXPENSE.
C. CONTRACTOR SHALL PROTECT ADJACENT SURFACES IN
PREPARATION OF SAW CUTTING REQUIRED FOR DEMOLITION
ACTIVITIES.
GENERAL NOTES
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
AD121
SCALE : 3/32" = 1'-0"
FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN
KEYNOTES #
KEY PLAN
1 REMOVE EXISTING CEILING GRID, TILE, LIGHTING AND HVAC.
2 REMOVE EXISTING LIGHT FIXTURE.
3 REMOVE EXISTING CEILING TILES FROM HATCHED AREAS. CEILING
GRID TO REMAIN.
4 REMOVE EXISTING LIGHT FIXTURE. INFILL SPACE WITH SALVAGED
TILE.
UP
UP
UP
DEFGHJ
A L
IG
N
A L
IG
N
ALIGNALIGN
15' - 6 3/4"
/4
/2
13' - 6" 13' - 6" 13' - 1 1/2"
/8
/8
7' - 11 5/8"
A L
IG
N
/4
OPEN OFFICE
OFFICE
OFFICE
OFFICE
LARGE CONFERENCE
BREAK ROOM
STORAGE
CONFERENCE
SMALL CONF.
LARGE CONFERENCE
JUMBO CONFERENCE
STAIRS
ELEC.
ELEC.
MEDIUM CONFERENCE
OFFICE
OFFICE
OPEN OFFICE
OPEN OFFICE
OPEN OFFICE
A1
B
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3 M30
1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
M30 1,3
NOT IN SCOPE
A4214
A421
/2
6' - 5"
4' - 0"
1 1
A421
15' - 6 1/2" 2' - 4" 8' - 10 1/4"
20' - 9 1/8"
100A
100B
19' - 3 5/8"
3' - 11"
/8
4 4 4 4
A4216
A421 11 A421 11 A421 11
A42113
A421
A42115 14
A421
A421 19
ALIGN
M31
M31
M31
M31
A. REFER TO A003 FOR WALL TYPES, DETAILS, AND ADDITIONAL
INFORMATION.
B. REFER TO A120 SERIES DRAWINGS FOR REFLECTED CEILING PLANS
AND DETAILS.
C. REFER TO A140 SERIES DRAWINGS FOR FINISH PLANS, SCHEDULES,
AND DETAILS.
D. REFER TO A160 SERIES DRAWINGS FOR FURNITURE AND EQUIPMENT
PLANS AND SCHEDULES.
E. REFER TO A600 SERIES DRAWINGS FOR DOOR SCHEDULE, WINDOW
SCHEDULE, DETAILS, AND BASIS OF DESIGN.
F. ALL DOORS TO BE LOCATED 4" FROM DRYWALL ADJACENT WALL
UNLESS OTHERWISE NOTED.
G. ALIGN FACES OF MASONRY AND STUD WALLS INDICATED IN THE
SAME PLANE ON PLANS, U.O.N.
GENERAL NOTES
SCALE : 3/32" = 1'-0"
PARTIAL FIRST FLOOR PLAN
KEYNOTES #
1 RELOCATE EXISTING FIRE EXTINGUISHER.
2 INSTALL NEW CLERESTORY WINDOW.
3 PROVIDE BACKING FOR TV
4 PROVIDE BACKING FOR MARKERBOARD
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A101
T
TS
TS
TS
T
DEFGHJ
ACP-1
10'-6"
JUMBO CONFERENCE
MEDIUM CONFERENCE
ELEC.
ELEC.
STAIRS
OPEN OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
LARGE CONFERENCE
BREAK ROOM
STORAGE
CONFERENCE
SMALL CONF.
LARGE CONFERENCE
OPEN OFFICE
ACP-1
10'-6"
ACP-1
10'-6"
ACP-1
10' - 6"
ACP-1
9' - 0"
ACP-1
9' - 0"
ACP-1
9' - 0"
ACP-1
9' - 0"
ACP-1
9' - 0"
NOT IN SCOPE
CEILING LEGEND
NOTE: SEE OTHER DISCIPLINE DRAWINGS (E.G. MECHANICAL, PLUMBING
AND ELECTRICAL DRAWINGS) FOR ASSOCIATED SYSTEMS AND
INFORMATION ABOUT SYMBOLS NOT INDICATED IN THIS LEGEND.
5' x 5' SUSPENDED CEILING TILE
2' x 2' SUSPENDED CEILING TILE
1' X 4' LIGHT FIXTURE
2' X 4' LIGHT FIXTURE
PENDANT LIGHT FIXTURE
MECHANICAL SUPPLY
A. REFER TO A003 FOR WALL TYPES, DETAILS, AND ADDITIONAL
INFORMATION.
B. REFER TO A120 SERIES DRAWINGS FOR REFLECTED CEILING PLANS
AND DETAILS.
C. REFER TO A140 SERIES DRAWINGS FOR FINISH PLANS, SCHEDULES,
AND DETAILS.
D. REFER TO A160 SERIES DRAWINGS FOR FURNITURE AND EQUIPMENT
PLANS AND SCHEDULES.
E. REFER TO A600 SERIES DRAWINGS FOR DOOR SCHEDULE, WINDOW
SCHEDULE, DETAILS, AND BASIS OF DESIGN.
F. ALL DOORS TO BE LOCATED 4" FROM DRYWALL ADJACENT WALL
UNLESS OTHERWISE NOTED.
G. ALIGN FACES OF MASONRY AND STUD WALLS INDICATED IN THE
SAME PLANE ON PLANS, U.O.N.
GENERAL NOTES
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A121
SCALE : 3/32" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
KEYNOTES #
1 EXISTING CEILING AND LIGHTING TO REMAIN. REPLACE DAMAGED
CEILING TILES AS REQUIRED. REPLACEMENT TILES TO MATCH
EXISTING.
UP
UP
DEFGHJ
OPEN OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
LARGE CONFERENCE
JUMBO CONFERENCE
MEDIUM CONFERENCE
ELEC.
ELEC.
STAIRS
OPEN OFFICE
CONFERENCE
STORAGE
BREAK ROOM
SMALL CONF.
LARGE CONFERENCE
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1 CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
CPT-1
RB-1
PT-1 CPT-1
RB-1
PT-1
LVT-1
RB-1
PT-1
CPT-1
RB-1
PT-1
EX.
EX.
EX.
EX.
EX.
EX.EX.
EX.
EX.
NOT IN SCOPE
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2
PT-2PT-2
PT-2
PT-2
PT-2
PT-2
PT-2 PT-2
PT-2
PT-2
PT-2
PT-2
TS-1
FLOOR FINISH
WALL BASE FINISH
FLOOR FINISH ONLY
GENERAL WALL FINISH
WALL FINISH ABOVE WAINSCOT
WAINSCOT FINISH
WINDOW TREATMENT
SIGNAGE TAG
FINISH SYMBOL LEGEND
XX#
XX#
XX#
X#
X# X#
X#
ACCENT WALL FINISH - TO EXTENTS
X#
X#
GENERAL NOTES
A. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR
PREPARING AND INSTALLING FINISHES.
B. PROTECT ADJACENT WORK BY SUITABLY COVERING DURING WORK.
C. REMOVE ADHESIVE OR PAINT SPOTS FROM FINISHED FLOORS,
WALLS, GLASS OR OTHER SURFACES. FINISHES TO MEET OR
EXCEED CODE REQUIREMENTS.
D. INSTALL MATERIALS USING MANUFACTURER'S APPROVED
ADHESIVES AND METHODS, U.O.N.
E. FILL MINOR DRYWALL IRREGULARITIES WITH SPACKLING COMPOUND
AND SAND TO A SMOOTH LEVEL SURFACE. EXERCISE CARE TO AVOID
RAISING THE NAP OF PAPER
F. DO NOT PERFORM PAINTING AND OTHER FINISHING WORK UNDER
CONDITIONS UNSUITABLE FOR EXECUTION OF PAINTING WORK. AIR
SHALL BE FREE FROM DUST AND DIRT TO PREVENT LODGING OF
FOREIGN MATTER IN FRESH PAINT. FLOORS MUST BE BROOM CLEAN
BEFORE PAINTING IS STARTED.
G. PAINT DESIGNATIONS INDICATE COLOR ONLY, REFER TO
SPECIFICATION FOR FINISH TYPE.
H. EDGES OF PAINT ADJOINING OTHER COLORS OR MATERIALS TO BE
SHARP AND CLEAN WITHOUT OVERLAP.
I. EXAMINE SURFACES TO RECEIVE PAINT CAREFULLY FOR DEFECTS.
DO NOT PROCEED WITH WORK UNTIL DEFECTS ARE CORRECTED.
J. WHENEVER NECESSARY TO OBTAIN REQUIRED RESULTS, REFINISH
AN ENTIRE WALL RATHER THAN SPOT FINISHING WHERE A PORTION
OF THE FINISH HAS BEEN DAMAGED OR IS UNSATISFACTORY.
K. PREPARE FLOOR SURFACES INCLUDING, BUT NOT LIMITED TO, THE
FOLLOWING:
A. PREPARE/PROPERLY REPAIR AND PATCH SUBFLOORS TO A
SMOOTH AND LEVEL FINISH.
B. FLASH PATCH AS REQUIRED, READY TO RECEIVE NEW FINISH.
L. PROVIDE SELF LEVELING TROWELABLE UNDERLAYMENT WHERE
REQUIRED TO OBTAIN FINISH MANUFACTURER'S REQUIRED
SUBFLOOR CONDITION.
M. FOLLOW THE CARPET AND RUG INSTITUTE METHODS OF
INSTALLATION.
N. INSTALL TILE PER THE TILE COUNCIL OF NORTH AMERICA'S
INSTALLATION SPECIFICATIONS.
O. PROVIDE THE REQUIRED TRANSITIONS BASED ON TYPES IDENTIFIED
ON DRAWINGS AT EACH FINISH TRANSITION LOCATION
P. CENTER FLOOR MATERIAL TRANSITIONS ON DOOR ABOVE.
Q. FINISHED FLOORS EXTEND INTO TOE SPACES, CLOSETS, DOOR
REVEALS AND SIMILAR OPENINGS.
R. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISHES.
S. REFER TO ELEVATIONS FOR MILLWORK FINISHES.
09 51 13 ACOUSTIC PANEL CEILINGS
09 65 13 RESILIENT BASE AND ACCESSORIES
08 14 16 FLUSH WOOD DOORS
BASIS OF DESIGN
WD-1
MANUFACTURER: FORTE
STYLE: CENDURA SERIES
TYPE: MATCH EXISTING
COLOR: MATCH EXISTING
ACT-1
MANUFACTURER: ARMSTRONG
TYPE: CIRRUS ANGLED TEGULAR HUMIGUARD PLUS
SIZE: 2' X 2'
GRID: MATCH EXISTING
COLOR: WHITE
RB-1
MANUFACTURER: JOHNSONITE
STYLE: TRADITIONAL VINYL 1/8" (TYPE TV)
SIZE: 4" TOE
COLOR: TOAST 283
NOTE: PROVIDED AND INSTALLED BY STATE - INSTALLATION
TO BE COORDINATED WITH G.C.
09 65 00 RESILIENT FLOORING
LVT-1
MANUFACTURER: TARKETT
STYLE: ID LATITUDE STONE AND CONCRETE
COLOR: WEATHERED GLAZE 7549
SIZE: 18" X 18"
PATTERN: HORIZONTAL ASHLAR
NOTE: PROVIDED AND INSTALLED BY STATE - INSTALLATION
TO BE COORDINATED WITH G.C.
09 68 13 TILE CARPETING
09 91 23 INTERIOR PAINTING
CPT-1
MANUFACTURER: TARKETT
PATTERN: TEXTURE MAP 1129
COLOR: NOCTURNAL 42807
SIZE: 24" X 24" VERTICAL ASHLAR
NOTE: PROVIDED AND INSTALLED BY STATE - INSTALLATION
TO BE COORDINATED WITH G.C.
PT-1
MANUFACTURER: SHERWIN WILLIAMS
COLOR: ACCESSIBLE BEIGE SW7036
FINISH: EGGSHELL
LOCATION: FIELD PAINT COLOR
PT-2
MANUFACTURER: SHERWIN WILLIAMS
COLOR: DENIM SW 6523
FINISH: EGGSHELL
LOCATION: ACCENT PAINT COLOR
12 24 13 ROLLER WINDOW SHADES
RS-1
NOTE: EXISTING TO REMAIN
PT-3
MANUFACTURER: SHERWIN WILLIAMS
COLOR: QUIVER TAN SW6151
FINISH: SEMI-GLOSS
LOCATION: DOOR FRAMES AND CLERESTORY WINDOWS
BASIS OF DESIGN - CONTINUED
09 65 13 RESILIENT BASE AND ACCESSORIES
TS-1
MANUFACTURER: JOHNSONITE
STYLE: ADAPTOR
COLOR: TOAST 283
NOTE: PROVIDED AND INSTALLED BY STATE - INSTALLATION
TO BE COORDINATED WITH G.C.
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A141
SCALE : 3/32" = 1'-0"
FIRST FLOOR FINISH PLAN
ROOM FINISH SCHEDULE
ROOM
FLOOR BASE
WALL FINISH
CEILING FINISH REMARKSNUMBER NAME NORTH EAST SOUTH WEST
FIRST FLOOR
100 OPEN OFFICE CPT-1 RB-1 PT-1/PT-2 PT-1/PT-2 PT-1/PT-2 PT-1/PT-2 EXIST.
101 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 APC-1
102 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 APC-1
103 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-2 APC-1
104 LARGE CONFERENCE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 APC-1
105 BREAK ROOM LVT-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXIST.
106 STORAGE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 APC-1
107 CONFERENCE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 APC-1
108 SMALL CONF. CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 EXIST.
109 LARGE CONFERENCE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 APC-1
110 JUMBO CONFERENCE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 APC-1
111 STAIRS EX. EX. EX. EX. EX. EX. EXIST.
112 ELEC. EX. EX. EX. EX. EX. EX. EXIST.
113 ELEC. EX. EX. EX. EX. EX. EX. EXIST.
114 MEDIUM CONFERENCE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 APC-1
115 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 EXIST.
116 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-2 PT-1 EXIST.
FLOOR
BOX
FLOOR
BOX
FLOOR
BOX
FLOOR
BOX
FLOOR
BOX
FLOOR
BOX
FLOOR
BOX
FLOOR
BOX
UP
UP
UP
UP
UP
DEFGHJ
1LARGE CONFERENCE
OPEN OFFICE
CONFERENCE
SMALL CONF.
STORAGE
BREAK ROOM
JUMBO CONFERENCE
STAIRS
ELEC.
ELEC.
MEDIUM CONFERENCE
LARGE CONFERENCE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
OPEN OFFICE
SCALE : 3/32" = 1'-0"
FIRST FLOOR FFE PLAN
1 FURNITURE, FIXTURES AND EQUIPMENT TO BE RELOCATED BY DBI.
INSTALLATION AND ELECTRICAL CONNECTIONS TO BE
COORDINATED WITH G.C.
KEYNOTES #
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A161
EQ. 5' - 0"
6"
5' - 0" 6"
5' - 0" EQ.
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
CLERESTORY
WINDOW, TYP.
4"5' - 0"1' - 6"
EQ.
5' - 0"6"5' - 0"
EQ.
4' - 0"
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
CLERESTORY
WINDOWS
DOOR AND FRAME PER
SCHEDULE, TYP.
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
CLERESTORY WINDOWS
8 7/8" 5' - 0" 6" 5' - 0" 6" 5' - 0"
DOOR AND FRAME, PER SCHEDULE
MARKERBOARD
EXISTING GYPSUM BOARD WALL SYSTEMNEW GYPSUM BOARD WALL
3' - 0"
EQ. EQ.
MARKERBOARD, TYP.
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ.EQ.
DOOR AND FRAME
PER SCHEDULE
EQ. EQ.
TELEVISION
MARKERBOARD, TYP.
6"6"
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ.EQ.
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ.EQ.
MARKERBOARD, TYP.
BASE, PER
SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
DOOR AND FRAME
PER SCHEDULE
CLERESTORY WINDOWS
MARKERBOARD, TYP.
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
MARKERBOARD
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ.EQ.
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
DOOR AND FRAME
PER SCHEDULE
MARKERBOARD, TYP.
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
EQ. EQ.
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
MARKERBOARD
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ.EQ.
MARKERBOARD
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ.EQ.
TELEVISION
BASE, PER SCHEDULE
GYP. BRD., PAINTED
PER SCHEDULE
EQ. EQ.
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A421
SCALE : 3/16" = 1'-0"
MEDIUM CONFERENCE ROOM ELEVATION
SCALE : 3/16" = 1'-0"
JUMBO CONFERENCE ROOM ELEVATION
SCALE : 3/16" = 1'-0"
OPEN OFFICE ELEVATION
SCALE : 3/16" = 1'-0"
MED. CONF. - WEST WALL
SCALE : 3/16" = 1'-0"
MED. CONF. - SOUTH WALL
SCALE : 3/16" = 1'-0"
JUMBO CONF. ROOM - EAST WALL
SCALE : 3/16" = 1'-0"
JUMBO CONF. ROOM - WEST WALL
SCALE : 3/16" = 1'-0"
LARGE CONF. 104 -NORTH WALL
SCALE : 3/16" = 1'-0"
LARGE CONF. 104 - SOUTH WALL
SCALE : 3/16" = 1'-0"
LARGE CONF. 104 - WEST WALL
SCALE : 3/16" = 1'-0"
OFFICE - TYP. EAST WALL
SCALE : 3/16" = 1'-0"
OFFICE 115 - SOUTH WALL
SCALE : 3/16" = 1'-0"
OFFICE 115 - WEST WALL
SCALE : 3/16" = 1'-0"
CONF. 107 EAST WALL
SCALE : 3/16" = 1'-0"
CONF. 107 - WEST WALL
SCALE : 3/16" = 1'-0"
SMALL CONF. 108 - EAST WALL
SCALE : 3/16" = 1'-0"
SMALL CONF. 108 - SOUTH WALL
SCALE : 3/16" = 1'-0"
LARGE CONF. 109 - NORTH WALL
SCALE : 3/16" = 1'-0"
LARGE CONF. 109 - EAST WALL
3 ANCHORS PER JAMB
HOLLOW METAL
DOOR FRAME
/2
/8
TYP.
U.N.O.
2"
5/8"
DOUBLE STUDS
TYP. @ JAMBS
SEE WALL TYPES FOR
WALL CONSTRUCTION &
MATERIALS
A
1 2
S E
E S
C H
E D
U L
E
2"
SCHEDULE
SEE 2"
2"
SCHEDULE
SEE2"
MATCH EXISTING
2"
M A
T C
H E
X
IS
T
IN
G
M A
T C
H E
X
IS
T
IN
G
S E
E S
C H
E D
U L
E
2"
SCHEDULE
SEE2"
MATCH EXISTING
2"
M A
T C
H E
X
IS
T
IN
G
M A
T C
H E
X
IS
T
IN
G
S E
E S
C H
E D
U L
E
2" 4' - 8" 2"
ACTIVE F
FLUSH
SCHEDULE
SEE
S E
E S
C H
E D
U L
E
2" 4' - 8" 2"
5' - 0"
HOLLOW METAL FRAME
TO MATCH DOOR FRAMES
AND SIDELIGHTS
3 ANCHORS PER JAMB
HOLLOW METAL DOOR
FRAME
/2
/8
TYP.
U.N.O.
2"
5/8"
DOUBLE STUDS
TYP. @ JAMBS
SEE WALL TYPES FOR
WALL CONSTRUCTION &
MATERIALS
A
EXISTING LAY-IN ACOUSTICAL
CEILING GRID AND TILE
WALL AS SCHEDULED
REMOVE EXISTING CEILING TILE
INSIDE ROOMS WHERE NEW
CEILING IS BEING INSTALLED.
OPEN OFFICEINTERIOR OF NEW ROOMS
NEW LAY-IN ACOUSTICAL
CEILING GRID AND TILE
A
1/
1.
A
B G
O T
T A
W A
B U
IL
D
IN
G
S
IG
V E
T O
S
T F
L O
O R
Y
D A
TE
SH
EE
T
ID
EN
TI
FI
C A
TI
O N N
O
IS
SU
ED
F O R
W
O
T T
A W
A S
T R
E E
T L A
N S
IN
G
M
I
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
L A
C H
R
.A
N C
A R
B D
IR
E
C T
O R
F A
C
IL
IT
IE
S A
N D
B U
S
IN
E S
S S
E R
V
IC
E S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
F
IL
E
N O
B
ID
S P E R M
IT
S
A R C H
IT
EC
T P R O
JE
C T N O
IN
D E X
N O
F
IN
A L R E C O R D
C O N S T R U C T
IO
N
D R A W N
D
ES
IG
N
ED
A P P R O
VE
D
C H
EC
K
ED
B
DF
DD
M
W e st S a g in a w H w y
S u it e
L a n s in g
M I o f f ic e
.8
.8 w w w
.c o lli e rs e n g i n e e ri n g
.c o m
DD
M
B
DF
A602
DOOR - JAMB DETAILS
DOOR - FRAME TYPESDOOR - TYPES
DOOR SCHEDULE
DOOR #
LOCATION OPENING SIZE DOOR LEAF INFORMATION FRAME INFORMATION
HARDWARE
GROUP
COMMENTSTO
WIDTH HEIGHT THICKNESS TYPE MATERIAL TYPE MATERIAL
JAMB
DETAILNAME
FIRST FLOOR
100A OPEN OFFICE 5' - 6" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST. 3
100B OPEN OFFICE 5' - 6" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST. 2
101 OFFICE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 01 1
102 OFFICE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 01 1
103 OFFICE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 01 1
104 LARGE CONFERENCE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 3 HM - PT A 03 1
105 BREAK ROOM 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
106 STORAGE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 1 HM - PT A 02 1,4
107 CONFERENCE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 03 1,4
108 SMALL CONF. 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
109 LARGE CONFERENCE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 03 1
110A JUMBO CONFERENCE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 3 HM - PT A 03 1
110B JUMBO CONFERENCE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 03 1
111 STAIRS 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
112 ELEC. 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
113 ELEC. 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
114 MEDIUM CONFERENCE 3' - 0" 7' - 0" 1 3/4" Active F WD - ST 2 HM - PT A 03 1
115 OFFICE 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
116 OFFICE 3' - 0" 7' - 0" 1 3/4" Active F - EXIST. - EXIST. EXIST.
DOOR AND HARDWARE NOTES
NO. COMMENTS
1 NEW DOOR FINISH TO MATCH EXISTING
2 DOOR ACCESS CONTROL FOR SIGMA EMPLOYEES ONLY
3 DOOR ACCESS CONTROL FOR SIGMA EMPLOYEES AND STATE OF MICHIGAN EMPLOYEES
4 INSTALL SALVAGED DOOR AND FRAME
HARDWARE SCHEDULE
SET 01 (OFFICE)
FOR USE ON DOOR #(s): 101 102 103
(3) HINGES
(1) OFFICE LEVER LOCKSET
(1) BUILDING STANDARD CORE - COORDINATE KEYING WITH DTMB
(1) DOORSTOP
(1) SET DOOR SILENCERS
SET 02 (STORAGE)
FOR USE ON DOOR #(s): 106
(3) HINGES
(1) STORAGE LEVER LOCKSET
(1) BUILDING STANDARD CORE - COORDINATE KEYING WITH DTMB
(1) DOORSTOP
(1) SURFACE CLOSER
(1) SET DOOR SILENCERS
SET 03 (PASSAGE)
FOR USE ON DOOR #(s): 104 107 109 110A 110B 114
(3) HINGES
(1) PASSAGE LEVER LOCKSET
(1) DOORSTOP
(1) SET DOOR SILENCERS
TYPICAL CLERESTORY WINDOW
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
EXIST. EXIST. EXIST. EXIST. EXIST. EXIST.
CLERESTORY WINDOW - FRAME DETAILWALL DETAIL
W
S
M
T
S
NO2
TS
THCO2
CO
MS
HS
H
KEYNOTE - NEW
CONTINUATION SYMBOL
NUMBER OF SHEET WHERE
DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
GENERAL MECHANICAL SYMBOLS
ROOM NAME AND NUMBER
POINT WHERE NEW
CONNECTS TO EXISTING
ITEM TO BE DEMOLISHED AREA NOT IN CONTRACT
# KEYNOTE - DEMOLITION#
REVISION NUMBER -
SHOWN ON PLANS
POINT OF DISCONNECTION
(E)
CAP
PLUG
2"
4"
4" 4"
PLUMBING AND PIPING SYMBOLS
PIPE RISE
PIPE DROP
PIPE TEE REDUCING 45
DEGREE TEE
45 DEGREE TEE
PIPE ACCESSORY TAGS
DOMESTIC WATER METER
CIRCUIT SETTER VALVE
BALL VALVE
CHECK VALVE
THREE WAY VALVE
BUTTERFLY VALVE
MOTORIZED CONTROL VALVE
PRESSURE REDUCING VALVE
SOLENOID VALVE
THREE WAY MOTORIZED
CONTROL VALVE
BACKFLOW PREVENTER
EXISTING PIPE
PIPING BEING DEMOLISHED
PIPE SIZE TAG (DIAMETER)
MAKE-UP WATER
MEDIUM PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE
LOW PRESSURE STEAM
LOW PRESSURE CONDENSATE
HEATING WATER SUPPLY
HEATING WATER RETURN
HIGH PRESSURE STEAM
HIGH PRESSURE CONDENSATE
FUEL GAS VENT
COOLING TOWER SUPPLY
COOLING TOWER RETURN
COMBUSTION AIR VENT
CHILLED WATER SUPPLY
CONDENSATE DRAIN
CHILLED WATER RETURN
CD
CHWR
CHWS
COMB
CTR
CTS
FGV
HPC
HPS
HWR
HWS
LPC
LPS
MPC
MPS
MU
2"
VACUUM
STEAM VENT
REFRIGERANT-SUCTION
REFRIGERANT-LIQUID
REFRIGERANT-HOT GAS
RADIANT HOT WATER SUPPLY
PUMP CONDENSATE
RADIANT HOT WATER RETURN
NATURAL GASNG
PC
RHWR
RHWS
RHG
RL
RS
SV
VAC
BOP: -48' - 3"
FLEX PIPE
PIPE GUIDE
PIPE ANCHOR
A
G
PIPE SLOPE TAG
BOTTOM OF PIPE ELEVATION
ABOVE FINISHED FLOOR
1/8" / 12" SLOPE
BALANCING VALVE
16"x8"
16"/8"
(E)
F
S
M
B
D
C
16"ø
E/A
O/A
T/A
L/A
R/A
S/A
EXHAUST AIR
OUTSIDE AIR
RELIEF AIR
RETURN AIR
SUPPLY AIR
TRANSFER AIR
EXISTING DUCT TAG
OVAL DUCT SIZE TAG (WIDTH / HEIGHT)
SQUARE DUCT SIZE TAG (WIDTH x HEIGHT)
RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISE
RECTANGULAR RETURN/TRANSFER AIR DUCT RISE
ROUND DUCT SIZE TAG (DIAMETER)
DUCT BEING DEMOLISHED
ROUND SUPPLY/OUTSIDE AIR DUCT RISE
ROUND RETURN/TRANSFER AIR DUCT RISE
RECTANGULAR EXHAUST/RELIEF AIR DUCT RISE
ROUND EXHAUST/RELIEF AIR DUCT RISE
DROP
DROP
DROP
DROP
DROP
DROP
GE/A GREASE EXHAUST AIR
SE/A SMOKE EXHAUST AIR
FLUE EXHAUST GAS FLUE
C/A COMBUSTION AIR
S-O/A CONDITIONED OUTSIDE AIR
DAMPER TAGS
MANUAL BALANCING DAMPER
BACKDRAFT DAMPER
COMBINATION FIRE/SMOKE
DAMPER
FIRE DAMPER
SMOKE DAMPER
MOTORIZED DAMPER
ELBOW WITH
TURNING VANES
R
RADIUS ELBOW
CENTER LINE RADIUS (R = 1.5 x W)
OPPOSED BLADE DAMPER PARALLEL BLADE DAMPER
FLEX DUCT
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .