25M027CN Building HP465 Paint and Flooring Repairs PS.pdf

PDF 51 KB Posted

Attached to
Building HP275 and HP465 paint and Flooring Repairs
Solicitation number
N40085-26-R-9039
Issued by

About this file

This document is a product specifications and finishes schedule for an interior construction project under NAVFAC (Naval Facilities Engineering Command) oversight.

The specification details approved basis-of-design finishes for various interior spaces, including: Benjamin Moore paint for primary walls (1548 Classic Gray) and sleeping rooms (1552 River Reflections); Sherwin Williams paint for door frames (SW 7026 Griffin) and GWB/exposed ceilings (SW 7102 White Flour); Mannington luxury vinyl tile flooring for sleeping rooms (Crisscross Zoom Charcoal) and offices (Access Stone Linear Stone Shale); Schluter transition strips in satin anodized finish; Johnsonite rubber base (283 Toast); Inpro stainless steel corner guards; and Dur-A-Flex epoxy resinous flooring (DUR-A-QUARTZ Q28-23) for lounges and shared spaces. A wall graphic reading "Find Your Level" in Lindsey II Beige is specified for the lounge.

Key contractual requirements mandate that: the listed manufacturers represent approved basis of design only and equivalent products from other manufacturers are acceptable if reviewed by the project manager and approved by the NAVFAC Contracting Officer; the contractor is responsible for ordering materials on schedule to avoid delays and must not substitute items due to lead times; all interior finishes in vertical exit ways, exit lobbies, and exit corridors must meet minimum Class A fire rating; electrical panels, access panels, and expansion joints must be spray-painted to match adjacent wall colors; all materials must be installed per manufacturer specifications; and all flooring transitions must comply with ABA guidelines and be centered under doors.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAME LOCATION MANUFACTURER MODEL COLOR SIZE

PAINT PRIMARY WALLS BENJAMIN MOORE 1548 CLASSIC GRAY -

ACCENT PAINT SLEEPING ROOMS BENJAMIN MOORE 1552 RIVER REFLECTIONS -

PAINT DOOR FRAMES SHERWIN WILLIAMS SW 7026 GRIFFIN -

PAINT GWB & EXPOSED CEILINGS SHERWIN WILLIAMS SW 7102 WHITE FLOUR -

WALL GRAPHIC LOUNGE FIND YOUR LEVEL LINDSEY II BEIGE -

LUXURY VINYL TILE SLEEPING ROOMS MANNINGTON CRISSCROSS ZOOM CHARCOAL -

LUXURY VINYL TILE OFFICES MANNINGTON ACCESS STONE LINEAR STONE SHALE -

RUBBER BASE PRIMARY BASE JOHNSONITE 283 TOAST -

TRANSITION STRIP LVT TO TILE SCHLUTER RENO-U AEU 35 SATIN ANODIZED -

TRANSITION STRIP LVT TO CONCRETE OR EPOXY SCHLUTER RENO-U AEU 100 SATIN ANODIZED -

CORNER GUARD OUTSIDE CORNERS INPRO TYPE 430 STAINLESS STEEL -

EPOXY RESINOUS FLOORING LOUNGE & SHARED SPACES DUR-A-FLEX DUR-A-QUARTZ Q28-23 -

GENERAL NOTES

• FINISHES INDICATED ARE THE APPROVED BASIS OF

DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND

SALIENT CHARACTERISTICS ONLY. THE LISTING OF

MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT

THE SELECTION OF PRODUCTS PROVIDED BY OTHER

MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA

WILL BE CONSIDERED AND MUST BE REVIEWED BY THE

PROJECT MANAHGER AND APPROVED BY THE NAVFAC

CONTRACTING OFFICER.

FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT

LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM

CLASS A RATING.

• SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL

COLOR. PANELS PAINTED BY BRUSH ARE NOT

ACCEPTABLE.

• ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS.

• ALL FLOORING TRANSITIONS MUST MEET ABA

GUIDELINES. FLOORING TRANSITIONS OCCURRING UNDER

DOORS MUST BE CENTERED UNDER DOOR.

PRODUCT SPECIFICATIONS