25M026CN Building HP275 Paint and Flooring Repairs PS.pdf

PDF 51 KB Posted

Attached to
Building HP275 and HP465 paint and Flooring Repairs
Solicitation number
N40085-26-R-9039
Issued by

About this file

This document is a finishes specification sheet detailing approved materials and products for an interior construction project under NAVFAC oversight. The specifications establish the basis of design for colors, patterns, textures, and characteristics across multiple finish categories, with manufacturers and models listed as reference standards rather than exclusive selections.

The finishes specifications cover paint selections (Benjamin Moore and Sherwin Williams products for primary walls, sleeping rooms, door frames, and ceilings in colors including Classic Gray, River Reflections, Griffin, and White Flour), flooring materials (Mannington luxury vinyl tile in Crisscross Zoom Charcoal and Access Stone Linear Stone Shale for sleeping rooms and offices), rubber base (Johnsonite Toast), transition strips (Schluter Reno-U models in satin anodized finish), corner guards (Inpro Type 430 stainless steel), and epoxy resinous flooring (Dur-A-Flex Dur-A-Quartz Q28-23 for lounges and shared spaces). General notes specify that equivalent products from other manufacturers may be substituted upon project manager review and NAVFAC Contracting Officer approval; however, finishing items cannot be substituted due to ordering lead times, placing responsibility on the contractor to order materials timely. Additional requirements mandate that all interior finishes in vertical exit ways, exit lobbies, and corridors meet minimum Class A rating; electrical panels, access panels, and expansion joints must be spray-painted to match adjacent wall colors; all materials must be installed per manufacturer requirements; and all flooring transitions must comply with ABA guidelines and be centered under doors where applicable.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAME LOCATION MANUFACTURER MODEL COLOR SIZE

PAINT PRIMARY WALLS BENJAMIN MOORE 1548 CLASSIC GRAY -

ACCENT PAINT SLEEPING ROOMS BENJAMIN MOORE 1552 RIVER REFLECTIONS -

PAINT DOOR FRAMES SHERWIN WILLIAMS SW 7026 GRIFFIN -

PAINT GWB & EXPOSED CEILINGS SHERWIN WILLIAMS SW 7102 WHITE FLOUR -

WALL GRAPHIC LOUNGE FIND YOUR LEVEL LINDSEY II BEIGE -

LUXURY VINYL TILE SLEEPING ROOMS MANNINGTON CRISSCROSS ZOOM CHARCOAL -

LUXURY VINYL TILE OFFICES MANNINGTON ACCESS STONE LINEAR STONE SHALE -

RUBBER BASE PRIMARY BASE JOHNSONITE 283 TOAST -

TRANSITION STRIP LVT TO TILE SCHLUTER RENO-U AEU 35 SATIN ANODIZED -

TRANSITION STRIP LVT TO CONCRETE OR EPOXY SCHLUTER RENO-U AEU 100 SATIN ANODIZED -

CORNER GUARD OUTSIDE CORNERS INPRO TYPE 430 STAINLESS STEEL -

EPOXY RESINOUS FLOORING LOUNGE & SHARED SPACES DUR-A-FLEX DUR-A-QUARTZ Q28-23 -

GENERAL NOTES

• FINISHES INDICATED ARE THE APPROVED BASIS OF

DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND

SALIENT CHARACTERISTICS ONLY. THE LISTING OF

MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT

THE SELECTION OF PRODUCTS PROVIDED BY OTHER

MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA

WILL BE CONSIDERED AND MUST BE REVIEWED BY THE

PROJECT MANAHGER AND APPROVED BY THE NAVFAC

CONTRACTING OFFICER.

FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT

LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM

CLASS A RATING.

• SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL

COLOR. PANELS PAINTED BY BRUSH ARE NOT

ACCEPTABLE.

• ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS.

• ALL FLOORING TRANSITIONS MUST MEET ABA

GUIDELINES. FLOORING TRANSITIONS OCCURRING UNDER

DOORS MUST BE CENTERED UNDER DOOR.

PRODUCT SPECIFICATIONS