250617_CCGA_Jones and ACN Window Replacement_.pdf
PDF 17 MB Posted
- Solicitation number
- PE-56300-RFQ-2026-000000021
- Issued by
- Dooly County, Georgia
About this file
This is an architectural drawing and bidding document for a window replacement project at the College of Coastal Georgia (CCGA) involving two buildings: the Jones Building and the Academic Commons North (ACN) Building, located in Brunswick, Georgia. The project scope includes the removal and replacement of existing window assemblies and glazing across both facilities. The general contractor is required to field verify all existing window types, locations, and dimensions, with all work to comply with current performance specifications and code requirements, including the 2018 International Building Code with Georgia Amendments (2020-2024) and related codes. The project is structured with a base bid and two alternates: the base bid involves removing and replacing only the existing window glazing while carefully cleaning and repairing existing aluminum frames for reuse; Alternate #1 includes removal and replacement of portions of existing aluminum window framing as required with selective reuse where possible; and Alternate #2 entails complete removal of all existing aluminum window assemblies and installation of new aluminum frame assemblies with new insulated panels and louvers as needed. All completed assemblies are to feature low-E tempered thermally broken glazing with tinting to match adjacent CCGA buildings, with new aluminum components in Alternate #2 to be clear anodized. The bid set is dated 6/17/2025 and prepared by Newbrock Architects.
The document does not contain pricing information, contract award dates, contract terms, renewal options, set-asides, incumbent contractor information, funding sources, or response deadlines. No bidders conference, site visit scheduling, or submission instructions are included in this architectural drawing package. The drawings serve as reference materials for general contractors to develop accurate bids based on field verification of existing conditions, with multiple sheets detailing floor plans, exterior elevations, and existing window details for both the Jones Building and ACN Building.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 250617_Specs_COVER_TOC_MODIFIED_Jones_ACN_Win.pdf | ||
| BID Invitation ACN Jones Windows.docx | DOCX document | |
| STATEMENT OF BIDDER QUALIFICATIONS.docx | DOCX document | |
| SPD_AP005 Notice of Award.doc | DOC document | |
| PreBid Meeting Sheet CCGA 2524_ACN and Jones .pdf | ||
| SPD_AP005 Notice of Award for ACN _ Jones Win.doc | DOC document | |
| 250617_CCGA_Jones_and_ACN_WindowReplacement_B.pdf | ||
| DBB_Contract___Bid_Forms___Window replacement.docx | DOCX document | |
| SPD_AP004 Notice of Intent Award CCGA 2524 Wi.pdf | ||
| DBB_Full_Document_May_2025 (6).docx | DOCX document | |
| BID REQUIREMENTS _ INSTRUCTIONS _ FORMS 2 ACN.docx | DOCX document | |
| Please see questions below _Window.docx | DOCX document | |
| Bid Tab CCGA_2524 _ ACN and Jones.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
200' - 0" +/- EXISTING
E
X
IS
T
IN
G
A102
A1021
A102
A102 2
ALL COMPONENTS
OTHER THAN WINDOW
ASSEMBLIES TO REMAIN
ALL COMPONENTS OTHER THAN
WINDOW ASSEMBLIES TO REMAIN
EXISTING WINDOW ASSEMBLIES TO
BE REPLACED- G.C. TO FIELD
VERIFY ALL TYPES, LOCATIONS,AND
DIMENSIONS, TYP.
WINDOW
ASSEMBLIES
LEVEL 2
EXISTING WINDOW ASSEMBLIES TO
BE REPLACED- G.C. TO FIELD
VERIFY ALL TYPES, LOCATIONS,AND
DIMENSIONS, TYP.
NORTH
A103 2
A103
A103
A1031
ALL COMPONENTS
OTHER THAN WINDOW
ASSEMBLIES TO REMAIN
EXISTING WINDOW ASSEMBLIES TO BE
REPLACED- G.C. TO FIELD VERIFY ALL TYPES,
LOCATIONS,AND DIMENSIONS, TYP.
EXISTING WINDOW
ASSEMBLIES LEVEL 1 AND
2 THIS SIDE OF BLDG
N O
R T
H
163' - 2" +/- EXISTING
E
X
IS
T
IN
G
28' - 2"
ALL COMPONENTS
OTHER THAN WINDOW
ASSEMBLIES TO REMAIN
CCGA-
JONES
BUILDING
CCGA- ACADEMIC
COMMONS NORTH
(ACN)
CCGA- CORRELL
CENTER
CCGA- CAMPUS
CENTER
A L
T A
M A
A V
E
NORTH
COLLEGE OF
COASTAL GEORGIA
AREA PLAN
NOT TO SCALE
BASE BID AND ALTERNATES FOR BIDDING FOR GENERAL
CONTRACTOR:
1. BASE BID FOR PROJECT BIDDING: REMOVE AND REPLACE THE
EXISTING WINDOW GLAZING ONLY- CAREFULLY CLEAN AND
REPAIR EXISTING ALUM. FRAME FOR REUSE- COMPLETED
ASSEMBLIES WITH EXISTING ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
REVIEW WITH OWNER AND ARCHITECT
2. ALTERNATE #1: REMOVE AND REPLACE THE EXISTING WINDOW
GLAZING. REMOVE AND REPLACE PORTIONS OF EXISTING
ALUMINUM WINDOW FRAMING AS REQUIRED- REUSE EXISITNG
ALUMINUM WINDOW FRAMING WHERE POSSIBLE- CAREFULLY
CLEAN AND REPAIR EXISTING ALUMINUM FRAME FOR REUSE
WHERE POSSIBLE- COMPLETED ASSEMBLIES WITH EXISTING
AND NEW COMPONENTS OF ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
REVIEW WITH OWNER AND ARCHITECT
3. ALTERNATE #2: REMOVE AND REPLACE ALL EXISITING
ALUMINUM WINDOW ASSEMBLIES AND COMPONENTS TO
ROUGH OPENINGS. INSTALL NEW ALUM WINDOW FRAME
ASSEMBLIES TO INCLUDE NEW INSULATED PANELS AND
LOUVERS AS NEEDED- COMPLETED ALUMINUM ASSEMBLIES
WITH NEW COMPONENTS OF ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
NEW ALUMINUM COMPONENTS TO BE CLEAR ANODIZED
ALUMINUM.- REVIEW WITH OWNER AND ARCHITECT
N E
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E N
T
R E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
C O
V E
R S
H E
E T
A N
D F
L O
O R
P
LA
N R
E F
E R
E N
C E
S
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
-J
O N
E S
A
C N
B
LD
G S
W
IN
D O
W R
E P
L A
C E
M E
N T
6/17/2025
BID SET
A101
C
O
LL
EG
E
D R
IV
B
U N
SW
IC
K, G
A
SCALE: 1/16" = 1'-0"A101
2 FLOOR PLAN-JONES BLDG-FLOOR PLAN REFERENCE
SCALE: 1/16" = 1'-0"A101
FLOOR PLAN-ACADEMIC COMMONS NORTH BLDG-FLOOR PLAN
REFERENCE
General Contractor to verify the following codes are currently enforced with all AHJ and that all are implemented for all work:
• International Building Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Residential Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Fire Code, 2018 Edition, (State Fire Marshal Office)
• Life Safety Code NFPA 101, 2018 Edition, State Fire Marshal Office
• International Plumbing Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Mechanical Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Fuel Gas Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Swimming Pool and Spa Code, 2018 Edition, with Georgia Amendments (2020-2024)
• National Electrical Code, 2020 Edition with Georgia Amendments 2021
• International Energy Conservation Code, 2015 Edition, with Georgia Supplements and Amendments (2020-2024)
• International Property Maintenance Code, 2012 Edition, with Georgia Amendments (2015-2024)
• International Existing Building Code, 2012 Edition, with Georgia Amendments (2015-2024)
• International Residential Code High Wind Region, 2009
BASE BID AND ALTERNATES FOR BIDDING FOR G.C.
SHEET INDEX:
A101: COVER SHEET- AREA PLAN- FLOOR PLAN REFERENCES
A102: EXTERIOR ELEVATIONS- CCGA JONES BLDG
A103: EXTERIOR ELEVATIONS- CCGA ACN BLDG
A104: EXISTING DETAILS- JONES BLDG- FOR REFERENCE
ONLY -NOT TO SCALE (JONES IS FORMER SCIENCE
BLDG)
A105: EXISTING DETAILS- JONES BLDG- FOR REFERENCE
ONLY -NOT TO SCALE (JONES IS FORMER SCIENCE
BLDG
A106: EXISTING DETAILS- ACN BLDG- FOR REFERENCE ONLY -
NOT TO SCALE (ACN IS FORMER VOCATIONAL /
TECHNICAL BLDG)
X
IS
T
IN
G
/8
M .O
EXISTING
4' - 1" M.O. +/-
E X
IS
T
IN
G
E X
IS
T
IN
G
EXISTING INSULATED PANEL
EXISTING FIXED GLAZING
EXISTING (FORMER OPERABLE) NOW FIXED GLAZING
EXISTING INSULATED PANEL
EXISTING FIXED GLAZING
EXISTING (FORMER OPERABLE) NOW FIXED GLAZING
EXISTING INSULATED PANEL
EXISTING ALUM. SILL
A
EXISTING ALUM. MULLION & FRAME
ASSEMBLY
EXISTING WINDOW ASSEMBLY
TYPE A
AEXISTING WINDOW ASSEMBLY
TYPE A
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
AA EXISTING WINDOW ASSEMBLY
TYPE A
EXISTING WINDOW ASSEMBLY
TYPE A
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
EXISTING TO REMAIN
EXISTING TO REMAIN
EXISTING TO REMAIN
EXISTING TO REMAIN
EXISTING TO REMAIN
EXISTING GRILLES
TO REMAIN, TYP.
EXISTING
INSULALTED
PANELS TO REMAIN,
TYP.
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
ALL EXISTING
WINDOW ASSEMBLY
GLAZING TO BE
REPLACED, TYP.
4' - 1" +/- 1' - 4" +/-
4' - 1" +/-
/8
/2
/2
/2
EXISTING
20' - 9 1/2" +/-
EXISTING
12' - 8" +/-
EXISTING
12' - 8" +/-
EXISTING
20' - 9 1/2" +/-
EXISTING TO REMAIN EXISTING TO
REMAIN
EXISTING TO REMAIN EXISTING TO REMAIN
EXISTING TO
REMAIN
EXISTING TO REMAIN
EXISTING FIXED GLAZING PANELS
IN ALUM. FRAME TO BE REPLACED, TYP.
E X
IS
T
IN
G
M .O
NOTE: SOME ELEVATION
DETAILS OMITTED FROM DRAWINGS
FOR CLARITY- G.C. TO FIELD
VERIFY ALL EXISTING CONDITIONS
BASE BID AND ALTERNATES FOR BIDDING FOR GENERAL
CONTRACTOR:
1. BASE BID FOR PROJECT BIDDING: REMOVE AND REPLACE THE
EXISTING WINDOW GLAZING ONLY- CAREFULLY CLEAN AND
REPAIR EXISTING ALUM. FRAME FOR REUSE- COMPLETED
ASSEMBLIES WITH EXISTING ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
REVIEW WITH OWNER AND ARCHITECT
2. ALTERNATE #1: REMOVE AND REPLACE THE EXISTING WINDOW
GLAZING. REMOVE AND REPLACE PORTIONS OF EXISTING
ALUMINUM WINDOW FRAMING AS REQUIRED- REUSE EXISITNG
ALUMINUM WINDOW FRAMING WHERE POSSIBLE- CAREFULLY
CLEAN AND REPAIR EXISTING ALUMINUM FRAME FOR REUSE
WHERE POSSIBLE- COMPLETED ASSEMBLIES WITH EXISTING
AND NEW COMPONENTS OF ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
REVIEW WITH OWNER AND ARCHITECT
3. ALTERNATE #2: REMOVE AND REPLACE ALL EXISITING
ALUMINUM WINDOW ASSEMBLIES AND COMPONENTS TO
ROUGH OPENINGS. INSTALL NEW ALUM WINDOW FRAME
ASSEMBLIES TO INCLUDE NEW INSULATED PANELS AND
LOUVERS AS NEEDED- COMPLETED ALUMINUM ASSEMBLIES
WITH NEW COMPONENTS OF ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
NEW ALUMINUM COMPONENTS TO BE CLEAR ANODIZED
ALUMINUM.- REVIEW WITH OWNER AND ARCHITECT
N E
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
E X
T E
R
IO
R E
L E
V A
T
IO
N S
C
C G
A J
O N
E S
B
LD
G
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
-J
O N
E S
A
C N
B
LD
G S
W
IN
D O
W R
E P
L A
C E
M E
N T
6/17/2025
BID SET
A102
C
O
LL
EG
E
D R
U N
SW
IC
K, G
A
SCALE: 1/8" = 1'-0"A102
2 ELEVATION-SOUTH-JONES
SCALE: 1/8" = 1'-0"A102
1 ELEVATION-NORTH-JONES (SOUTH SIM.)
SCALE: 1/8" = 1'-0"A102
3 ELEVATION-WEST-ALTAMA AVE-JONES
SCALE: 1/8" = 1'-0"A102
4 ELEVATION-EAST-JONES
BASE BID AND ALTERNATES FOR BIDDING FOR G.C.
3' - 10" +/-
1' - 2" +/-
3' - 10" +/- 3' - 10" +/-
1' - 2" +/-
3' - 10" +/-
/2
/2
0"
EXISTING SPANDREL PANEL
EXISTING GLAZING
EXISTING GLAZING
EXISTING AGGREGATE PANEL
EXISTING SPANDREL PANEL
EXISTING GLAZING
EXISTING GLAZING
EXISTING AGGREGATE PANEL
EXISTING EXISTING STUCCO
OVER CONC. COLUMN
LEVEL 2
/2
" 1
/2
EXISTING DOOR AND
LOUVERS TO REMAIN
G.C. FIELD VERIFY ALL DIMS
16' - 2" +/- EXISTING
3' - 4" +/-
3' - 2" +/- 3' - 2" +/- 3' - 2" +/-
3' - 4" +/-
17' - 6" +/- 17' - 6" +/- 17' - 6" +/- 17' - 6" +/- 19' - 6" +/-
18' - 5" +/-28' - 2" +/-
27' - 1" +/-19' - 6" +/-27' - 1" +/-
EXISTING GLAZING
BASE BID AND ALTERNATES FOR BIDDING FOR GENERAL
CONTRACTOR:
1. BASE BID FOR PROJECT BIDDING: REMOVE AND REPLACE THE
EXISTING WINDOW GLAZING ONLY- CAREFULLY CLEAN AND
REPAIR EXISTING ALUM. FRAME FOR REUSE- COMPLETED
ASSEMBLIES WITH EXISTING ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
REVIEW WITH OWNER AND ARCHITECT
2. ALTERNATE #1: REMOVE AND REPLACE THE EXISTING WINDOW
GLAZING. REMOVE AND REPLACE PORTIONS OF EXISTING
ALUMINUM WINDOW FRAMING AS REQUIRED- REUSE EXISITNG
ALUMINUM WINDOW FRAMING WHERE POSSIBLE- CAREFULLY
CLEAN AND REPAIR EXISTING ALUMINUM FRAME FOR REUSE
WHERE POSSIBLE- COMPLETED ASSEMBLIES WITH EXISTING
AND NEW COMPONENTS OF ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
REVIEW WITH OWNER AND ARCHITECT
3. ALTERNATE #2: REMOVE AND REPLACE ALL EXISITING
ALUMINUM WINDOW ASSEMBLIES AND COMPONENTS TO
ROUGH OPENINGS. INSTALL NEW ALUM WINDOW FRAME
ASSEMBLIES TO INCLUDE NEW INSULATED PANELS AND
LOUVERS AS NEEDED- COMPLETED ALUMINUM ASSEMBLIES
WITH NEW COMPONENTS OF ALUMINUM FRAMES AND NEW
GLAZING ASSEMBLIES TO MEET ALL CURRENT PERFORMANCE
SPECIFICATIONS AND CODE REQUIREMENTS WITH LOW-E
TEMPERED THERMALLY BROKEN ASSEMBLIES- TINTING OF
GLAZING TO MATCH EXISTING ADJACENT CCGA CORRELL
CENTER AND ADJACENT CCGA CAMPUS CENTER BUILDINGS-
NEW ALUMINUM COMPONENTS TO BE CLEAR ANODIZED
ALUMINUM.- REVIEW WITH OWNER AND ARCHITECT
N E
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
E X
T E
R
IO
R E
L E
V A
T
IO
N S
C
C G
A A
C N
B L
D G
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
-J
O N
E S
A
C N
B
LD
G S
W
IN
D O
W R
E P
L A
C E
M E
N T
6/17/2025
BID SET
A103
C
O
LL
EG
E
D R
U N
SW
IC
K, G
A
SCALE: 1/8" = 1'-0"A103
1 CCGA-ACN-EAST ELEVATION
SCALE: 1/8" = 1'-0"A103
3 CCGA-ACN-NORTH ELEVATION
SCALE: 1/8" = 1'-0"A103
4 CCGA-ACN-SOUTH ELEVATION
SCALE: 1/8" = 1'-0"A103
2 CCGA-ACN-WEST ELEVATION (SIM. EAST ELEV.)
BASE BID AND ALTERNATES FOR BIDDING FOR G.C.
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
E X
IS
T
IN
G
D E
T A
IL
S
JO
N E
S B
LD
G
F
O R
R E
F E
R E
N C
E O
N L
Y
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
-J
O N
E S
A
C N
B
LD
G S
W
IN
D O
W R
E P
L A
C E
M E
N T
6/17/2025
BID SET
A104
C
O
LL
EG
E
D R
U N
SW
IC
K, G
A
EXISTING WINDOW DETAILS JONES BLDG 1- FOR REFERENCE ONLY
NOT TO SCALE
NOT TO SCALE - FOR REFERENCE ONLY - GENERAL CONTRACTOR
TO FIELD VERIFY ALL DIMENSIONS AND AS-BUILT CONDITIONS, TYP.
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
E X
IS
T
IN
G
D E
T A
IL
S
JO
N E
S B
L D
G
F O
R R
E F
E R
E N
C E
O N
LY
N
O T
T O
S C
A L
E
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
-J
O N
E S
A
C N
B
LD
G S
W
IN
D O
W R
E P
L A
C E
M E
N T
6/17/2025
BID SET
A105
C
O
LL
EG
E
D R
U N
SW
IC
K, G
A
EXISTING WINDOW DETAILS- FOR REFERENCE ONLY NOT TO SCALE
NOT TO SCALE - FOR REFERENCE ONLY - GENERAL CONTRACTOR
TO FIELD VERIFY ALL DIMENSIONS AND AS-BUILT CONDITIONS, TYP.
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
E X
IS
T
IN
G
D E
T A
IL
S
A
C N
B L
D G
F
O R
R E
F E
R E
N C
E O
N
LY
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
-J
O N
E S
A
C N
B
LD
G S
W
IN
D O
W R
E P
L A
C E
M E
N T
6/17/2025
BID SET
A106
C
O
LL
EG
E
D R
U N
SW
IC
K, G
A
EXISTING WINDOW DETAILS ACADEMIC COMMONS NORTH (ACN) BUILDING
FOR REFERENCE ONLY - NOT TO SCALE
NOT TO SCALE - FOR REFERENCE ONLY - GENERAL
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND
AS-BUILT CONDITIONS, TYP.
| A101 |
| A102 |
| A103 |
| A104 |
| A105 |
| A106 |
File details come from the government source that posted it. Updated .