250508 Los Angeles CA 898-034 Maintenance Plans 4 of 10.pdf
PDF 8 MB Posted
- Attached to
- Y1EB--Los Angeles National Cemetery construct a new Maintenance Complex and Corrects FCA Deficie
- Solicitation number
- 36C78625B0024
About this file
This document is a set of architectural plans for the Los Angeles National Cemetery Maintenance Facility project, specifically focusing on site plans, demolition details, floor plans, and architectural legends. The plans detail the construction of a new maintenance complex, including administration and storage buildings, maintenance bays, covered parking, and privacy walls. Key components include a maintenance building with routine and heavy maintenance bays, an administration building with offices and support spaces, equipment storage areas, and specialized facilities like a wash rack, vehicle lift, and hazardous materials storage.
The project involves demolishing existing structures on the site and constructing new buildings with specific architectural features such as clay tile roofing, brick walls, and careful restoration of existing elements. The design includes detailed specifications for wall types, mounting heights, and specialized equipment like air compressors, tire changers, and pressure washers. The plans are part of a bid document submittal for the Department of Veterans Affairs National Cemetery Administration, with the architectural work prepared by Vali Cooper International and JD Engineering, PC, dated May 24, 2023.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WS
1. EXISTING TREE TO REMAIN
2. GRAVEL MULCH - SEE PLANTING NOTE B.
PLANTING KEYED NOTES
QTY BOTANIC NAME COMMON NAME SIZE SPACING
53 PLUMBAGO AURICULATA CAPE LEADWORT 5 GAL. 72" O.C.
335 SF FESCUE-POA BLEND TURFGRASS SOD N.A. N.A.
PLANTING SCHEDULE
A. IN CASE OF DISCREPANCY IN PLANT QUANTITIES SHOWN ON THE PLANT LEGEND AND
THOSE SHOWN ON THE PLANTING PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL
GOVERN. CONTRACTOR SHALL VERIFY ALL QUANTITIES PRIOR TO BID AND
INSTALLATION. NO ADDITIONAL PAYMENT WILL BE MADE FOR ANY DISCREPANCIES IN
QUANTITIES BETWEEN THE PLANTING PLAN AND THE PLANT LIST.
B. GRAVEL MULCH SHALL MATCH EXISTING GRAVEL AS INDICATED IN THE
SPECIFICATIONS, INSTALLED AT A 3" DEPTH OVER LANDSCAPE FABRIC - SEE DETAIL
D4/LI501.
C. LANDSCAPE FABRIC SHALL BE MIN. 4 OZ. NON-WOVEN NEEDLE-PUNCHED
POLYPROPYLENE. OVERLAP ENDS 12" AND TURN DOWN EDGES 6" PER DETAIL
D4/LI501.
D. THE TOP OF MULCH SHALL BE 1" BELOW TOP OF ADJACENT CONCRETE SURFACES -
SEE DETAIL D4/LI501.
E. SHRUBS SHALL BE INSTALLED PER DETAILS D3 & F3/LI501.
F. IF THERE IS A DISCREPANCY IN THE FIELD OR NURSERY BETWEEN THE CONTAINER
SIZE CALLED OUT UNDER "CONTAINER" AND HEIGHT OR SPREAD CALLED OUT UNDER
"REMARKS", THE SPECIFIED PLANT MUST MEET HEIGHT OR SPREAD REQUIREMENTS
SPECIFIED UNDER "REMARKS", EVEN IF A LARGER CONTAINER SIZE IS REQUIRED TO
MEET THESE SPECIFICATIONS, AT NO ADDITIONAL COST TO THE GOVERNMENT.
G. SOD SHALL BE COMPRISED OF 95% DWARF TALL FESCUE, 5% BLUEGRASS BLEND, SEE
SPECIFICATIONS. TOP OF SOD ROOT MASS SHALL BE INSTALLED 1" BELOW TOP OF
ADJACENT CONCRETE SURFACES AND TOP OF IRRIGATION ROTORS PER DETAIL
D4/LI501.
PLANTING NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
A
B
C
D
E
F
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
Los Angeles, CA
898CM3034
N/A Project Director
05/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
LP101
PLANTING PLAN
BV ER
618 SF
EXTERIOR WASH
AREA
1055 SF
EMPLOYEE
PARKING
581 SF
ROUTINE
MAINTENANCE BAY
426 SF
SERVICE BAY
249 SF
TOOLS/PARTS
(workshop)
333 SF
OFFICE
237 SF
BREAK
43 SF
MECH/ICE
28 SF
STOR.
67 SF
F-TOIL
208 SF
M-LOCK
10 SF
STOR.
55 SF
STORAGE
105 SF
F-LOCK
71 SF
M-TOIL
112 SF
FLAMMABLE
738 SF
FUEL
STORAGE
11 11
1. REMOVE AND DISPOSE OF BUILDING IN ITS ENTIRETY INCLUDING ALL
FOUNDATIONS, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL ITEMS.
2. PREP/ EPOXY REPAIR WOOD DOOR, FRAME AND TRIM FOR NEW PAINT- SEE
HAZMAT DRAWINGS AND REPORT.
3. PREP/ EPOXY REPAIR WOOD WINDOWS AND TRIM FOR NEW PAINT - SEE HAZMAT
DRAWINGS AND REPORT.
4. PREP/ EPOXY REPAIR WOOD HEADERS AND TRIM FOR NEW PAINT - SEE HAZMAT
DRAWINGS AND REPORT.
5. REMOVE AND DISPOSE OF OVERHEAD DOORS. PREP/ EPOXY REPAIR WOOD
JAMBS AND HEADS FOR NEW PAINT.
6. REMOVE AND DISPOSE OF CLAY TILE ROOFING.
7. PREP/ EPOXY REPAIR WOOD SOFFITS, FACIAS AND MISC TRIM.
8. CLEAN BRICK GENTLY AND PREP FOR TUCKPOINTING AS REQUIRED. PERFORM A
CLEANING AND MORTAR MOCKUP IN A NON-CONSPICUOUS AREA.
9. REMOVE AND DISPOSE OF CABINETRY, TOILET COMPARTMENTS, TOILET
SPECIALTIES, PLUMBING FIXTURES AND HVAC - SEE PLUMBING AND MECHANICAL.
REMOVE ALL WATER AND SEWER PIPING. GROUT UNDERGROUND PICKING UP TO
SLAB ELEVATION.
10. REMOVE AND DISPOSE OF EXISTING CONCRETE WALL AND FOOTING.
11. REMOVE AND DISPOSE OF EXISTING CONCRETE SLAB.
12. REMOVE AND DISPOSE OF EXISTING BOLLARDS, SLABS, ELECTRICAL AND
CONTROLS SYSTEMS. MIDDLE FUEL TANK IS TO BE RELOCATED, SOUTH FUEL
TANK IS TO BE REMOVED BY MAINT. CONTRACTOR AND NORTH FUEL TANK IS TO BE
REMOVED BY THE GC.
13. REMOVE AND DISPOSE OF EXISITNG PREMANUFACTURED METAL BUILDING.
14. REMOVE AND DISPOSE OF CMU / STONE BUILDING.
15. REMOVE BRICK WALL INFILL OF OLD OPENING. KEEP BRICK FOR REPAIR OF MISC
BRICKS ON THE REST OF THE BUILDING. TEST BRICK FOR STRUCTURAL INTEGRITY
PRIOR TO REUSE.
(NOT ALL KEYED NOTES USED ON THIS
SHEET)DEMOLITION KEYED NOTES:
ARCH. LEGEND
NOTE: NOT ALL SYMBOLS USED
0 COLUMN NUMBER / GRID LINE
CENTER LINE
x'- x"
DIMENSION LINE
EXISTING TO BE REMOVED
EXISTING TO REMAIN
EXISTING TO REMAIN
NEW CONSTRUCTION
ROOM NAME
ROOM NAME
ROOM NUMBER
DOOR NUMBER SYMBOL
XX
X-XXX
1 Ref
1 A101
1 Ref
SHEET DETAIL IS DRAWN ON
DETAIL NUMBER
DETAIL NUMBER
ARCHITECTURAL ELEVATION
SHEET NUMBER
DETAIL NUMBER
X
X-XXX
SHEET NUMBER
ARCHITECTURAL SECTION
1i WINDOW TYPE
R e f
R e f
WALL TYPE#
5/8" GYPSUM BOARD - TYPE X
2' X 2' ACOUSTIC CEILING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI
Project Management
Construction Management
Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
S
EA
N
M. F ITZPATR
IC
K
C U s e rs \D a n ia H a b b o u b
\V a li C o o p e r
In te rn a ti o n a l\ V
A N
C A
L A
N C
G ra v e s it e E x p a n s io n
C o lu m b a ri u m
D o c u m e n ts
\a W o rk
F ile s
M a in te n a n c e
\7
B id
D o c s
R e v is io n s f o r S in g le
P ro je c t B id
.1
.2
\1
P la n s \C
A D
\L A
N C
C
M
M a in t_ A rc h it e c tu ra l.
rv t
/5 /2
:1
:1
A M
D-101
SITE & BUILDING DEMOLITION
PLAN
3/32" = 1'-0" E1
Site / Building Demolition Plan
Not to Scale C2
Site Aerial -1
Not to Scale E2
Site Aerial -2
FITZ TM
Revisions: Date:
15 9235 8
9 32
141011 13 12
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI
Project Management
Construction Management
Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
S
EA
N
M. F ITZPATR
IC
K
C U s e rs \D a n ia H a b b o u b
\V a li C o o p e r
In te rn a ti o n a l\ V
A N
C A
L A
N C
G ra v e s it e E x p a n s io n
C o lu m b a ri u m
D o c u m e n ts
\a W o rk
F ile s
M a in te n a n c e
\7
B id
D o c s
R e v is io n s f o r S in g le
P ro je c t B id
.1
.2
\1
P la n s \C
A D
\L A
N C
C
M
M a in t_ A rc h it e c tu ra l.
rv t
/5 /2
:1
:1
A M
D-102
DEMOLITION DETAILS
Not to Scale B2
Exist. Maintenance Building Section -1
Not to Scale D2
Exist. Maintenance Building Section -2
Not to Scale F2
Exist. Maintenance Building Section -3
Not to Scale B4
Exist. Maintenance Building -1
Not to Scale D4
Exist. Maintenance Building -2
Not to Scale F3
Exist. Brick Storage Building Not to Scale
F7 Exist. Brick Storage Building & Wash Rack
Not to Scale B7
Exist. Stone and Metal Buildings
Not to Scale D6
Exist. Stone and Metal Building -2 Not to Scale
D8 Exist. Metal Building and Fuel Tanks
ARCH. LEGEND
NOTE: NOT ALL SYMBOLS USED
0 COLUMN NUMBER / GRID LINE
CENTER LINE
x'- x"
DIMENSION LINE
EXISTING TO BE REMOVED
EXISTING TO REMAIN
EXISTING TO REMAIN
NEW CONSTRUCTION
ROOM NAME
ROOM NAME
ROOM NUMBER
DOOR NUMBER SYMBOL
XX
X-XXX
1 Ref
1 A101
1 Ref
SHEET DETAIL IS DRAWN ON
DETAIL NUMBER
DETAIL NUMBER
ARCHITECTURAL ELEVATION
SHEET NUMBER
DETAIL NUMBER
X
X-XXX
SHEET NUMBER
ARCHITECTURAL SECTION
1i WINDOW TYPE
R e f
R e f
WALL TYPE#
5/8" GYPSUM BOARD - TYPE X
2' X 2' ACOUSTIC CEILING
1. REMOVE AND DISPOSE OF BUILDING IN ITS ENTIRETY INCLUDING ALL
FOUNDATIONS, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL ITEMS.
2. PREP/ EPOXY REPAIR WOOD DOOR, FRAME AND TRIM FOR NEW PAINT- SEE
HAZMAT DRAWINGS AND REPORT.
3. PREP/ EPOXY REPAIR WOOD WINDOWS AND TRIM FOR NEW PAINT - SEE HAZMAT
DRAWINGS AND REPORT.
4. PREP/ EPOXY REPAIR WOOD HEADERS AND TRIM FOR NEW PAINT - SEE HAZMAT
DRAWINGS AND REPORT.
5. REMOVE AND DISPOSE OF OVERHEAD DOORS. PREP/ EPOXY REPAIR WOOD
JAMBS AND HEADS FOR NEW PAINT.
6. REMOVE AND DISPOSE OF CLAY TILE ROOFING.
7. PREP/ EPOXY REPAIR WOOD SOFFITS, FACIAS AND MISC TRIM.
8. CLEAN BRICK GENTLY AND PREP FOR TUCKPOINTING AS REQUIRED. PERFORM A
CLEANING AND MORTAR MOCKUP IN A NON-CONSPICUOUS AREA.
9. REMOVE AND DISPOSE OF CABINETRY, TOILET COMPARTMENTS, TOILET
SPECIALTIES, PLUMBING FIXTURES AND HVAC - SEE PLUMBING AND MECHANICAL.
REMOVE ALL WATER AND SEWER PIPING. GROUT UNDERGROUND PICKING UP TO
SLAB ELEVATION.
10. REMOVE AND DISPOSE OF EXISTING CONCRETE WALL AND FOOTING.
11. REMOVE AND DISPOSE OF EXISTING CONCRETE SLAB.
12. REMOVE AND DISPOSE OF EXISTING BOLLARDS, SLABS, ELECTRICAL AND
CONTROLS SYSTEMS. MIDDLE FUEL TANK IS TO BE RELOCATED, SOUTH FUEL
TANK IS TO BE REMOVED BY MAINT. CONTRACTOR AND NORTH FUEL TANK IS TO BE
REMOVED BY THE GC.
13. REMOVE AND DISPOSE OF EXISITNG PREMANUFACTURED METAL BUILDING.
14. REMOVE AND DISPOSE OF CMU / STONE BUILDING.
15. REMOVE BRICK WALL INFILL OF OLD OPENING. KEEP BRICK FOR REPAIR OF MISC
BRICKS ON THE REST OF THE BUILDING. TEST BRICK FOR STRUCTURAL INTEGRITY
PRIOR TO REUSE.
(NOT ALL KEYED NOTES USED ON THIS
SHEET)DEMOLITION KEYED NOTES:
GENERAL PARTITION NOTES
1. TESTING AGENCIES FOR THE FIRE ASSEMBLIES INDENTIFIED ON THE
PARTITION SCHEDULE ARE:
UL - UNDERWRITERS LABORATORY DESIGN NUMBER
GA - GYPSUM ASSOCIATION DESIGN NUMBER
2. CONCRETE AND OTHER STRUCTURAL WALLS DO NOT HAVE PARTITION
SYMBOLS, ALTHOUGH FURRING APPLIED TO SUCH WALL MAY BE INDICATED
WITH A PARTITION SYMBOL. EXTERIOR WALLS ARE LIKEWISE NOT DEFINED BY
PARTITION TYPES, ALTHOUGH FURRING ON THE INTERIOR SIDE MAY BE
INDICATED WITH A PARTITION SYMBOL.
3. PLAN DIMENSIONS ARE TYPICALLY TO GRID LINE, FACE OF PARTITION OR FACE
OF CONCRETE OR CMU UNLESS NOTED OR INDICATED OTHERWISE. DOORS
NOT LOCATED BY PLAN DIMENSION ARE LOCATED BY JAMB DETAILS
REFERENCED FROM DOOR SCHEDULE. CRITICAL CLEARANCES ARE
DESIGNATED "CLR".
4. THE PARTITION TYPE NOTED BY A SYMBOL CONTINUES BETWEEN CORNERS
AND BETWEEN INTERSECTING PARTITIONS. AT OPENINGS, PROVIDE THE SAME
PARTITION TYPE ABOVE AND BELOW SUCH OPENING AS THAT ON EITHER SIDE
OF THE OPENING. AT PARTITIONS SCHEDULED TO EXTEND TO STRUCTURE
ABOVE, EXTEND THE PARTITION AROUND AND ABOVE DUCTS, BEAMS AND
OTHER OBSTRUCTIONS. ALIGN DIFFERENT PARTITION THICKNESSES SO THAT
THE FINISHED WALL PLANES CONTINUE UNBROKEN WITHIN EACH ROOM OR
CORRIDOR, UNLESS NOTED OTHERWISE. WHERE FACE OF COLUMN FURRING
IS SHOWN AS ALIGNING WITH FACE OF PARTITION, CONTINUE PARTITION FACE
UNBROKEN PAST THE COLUMN. STANDARD COLUMN FURRING DETAILS
LOCATE PARTITION FACE.
5. WHERE GYPSUM BOARD IS NOT SCHEDULED TO EXTEND TO BOTTOM OF
STRUCTURE, BOARD MAY TERMINATE 4" ABOVE ABUTTING CEILING ON EACH
SIDE. IF NO CEILING IS SCHEDULED, BOARD IN THAT ROOM MUST EXTEND FULL
HEIGHT.
6. WHERE PARTITIONS ARE INDICATED AS BEING FIRE-RATED, CONTINUE
PARTITIONS UNBROKEN TO BOTTOM OF DECK ABOVE AND ALONG THE ENTIRE
PERIMETER OF THE SPACES BEING SEPARATED BY THE FIRE-RATED
PARTITIONS. CONTINUE FIRE-RATED PARTITION SEPARATIONS WITHOUT
INTERRUPTION WHERE THEY INTERSECT NON-RATED PARTITIONS.
7 WHERE COLUMNS, MECHANICAL CHASES, PIPING AND OTHER ELEMENTS ARE
LOCATED WITHIN A FIRE-RATED PARTITION, CONTINUE THE GYPSUM BOARD
AROUND BOTH SIDES OF THE OBSTRUCTION TO MAINTAIN THE RATED
ASSEMBLY. FOR DUCT, PIPE, CONDUIT AND OTHER PENETRATIONS PASSING
THROUGH A FIRE-RATED PARTITION, PROVIDE TIGHT FITTING FIRE-RATED
STOPPING ASSEMBLIES EQUAL TO ASSEMBLY RATING.
8. WHERE SMOKE AND FIRE-RATED PARTITIONS TERMINATE AT EXTERIOR
WALLS, FILL VOIDS WITH FIRE-RATED ASSEMBLIES, OR EXTEND THE RATED
PARTITIONS TO THE OUTER FACE OF EXTERIOR WALL CONSTRUCTIONS.
ENSURE THAT NO FLANKING PATHWAYS EXIST THAT MIGHT PERMIT SMOKE OR
FIRE TO FLOW FROM ONE SIDE OF THE PARTITION TO THE OTHER.
9. PROVIDE CONTINUOUS STANDARD BLOCKING AS DETAILED FOR WALL
MOUNTED ELEMENTS AT TOP AND BOTTOM ATTACHMENT POINTS AND AT
INTERMEDIATE ATTACHMENT POINTS AS REQUIRED BY THE ELEMENT,
INCLUDING, BUT NOT LIMITED TO ; ACCESSORIES, RAILINGS, FLOOR-MOUNTED
CASEWORK, CURTAIN RODS, WALL PROTECTION, CORNER GUARDS AND
EQUIPMENT WEIGHING LESS THAN 50 POUNDS.
10. PROVIDE HEAVY DUTY BLOCKING AS DETAILED FOR SUPPORT OF HEAVY
ELEMENTS, INCLUDING, BUT NOT LIMITED TO ; WALL MOUNTED SHELVING AND
CABINETRY, HAND RAILS, GRAB BARS, BABY-CHANGING TABLES, LAVATORIES,
COUNTERTOPS, MOUNTS FOR TELEVISIONS AND COMPUTER MONITORS, DOOR
STOPS AND EQUIPMENT WEIGHING IN EXCESS OF 50 POUNDS.
11. WHERE ACOUSTICAL INSULATION IS INDICATED FOR PARTITIONS, SEAL TOP,
BOTTOM AND SIDES OF EACH FACE AND EDGE OF GYPSUM BOARD WITH
ACOUSTICAL SEALANT WHERE THE BOARD CONTACTS OTHER MATERIALS.
12. BACK-TO-BACK ELECTRICAL BOXES ARE NOT PERMITTED UNLESS BOTH BOXES
ARE WRAPPED WITH ADHESIVE WRAPPED INTUMESCENT PUTTY PADS. WHERE
JUNCTION, OUTLET, AND SWITCH BOXES OCCUR ON OPPOSITE SIDES OF A
PARTITION, EITHER PROVIDE PUTTY PADS FOR BOTH BOXES OR OFFSET THE
BOXES A MINIMUM OF ONE STUD SPACE AND PROVIDE ACOUSTICAL
INSULATION BEHIND AND BETWEEN THEM.
14. PROVIDE ACOUSTICAL SEALANT AROUND ALL PENETRATIONS THROUGH THE
MEMBRANES OF ACOUSTICAL PARTITIONS. PROVIDE FIRE-RATED SEALANT IN
LIEU OF ACOUSTICAL SEALANT WHERE REQUIRED TO MAINTAIN FIRE RATING
OF ACOUSTIC PARTITIONS.
13. IN FIRE-RATED PARTITIONS WITH TOTAL "BACK BOX" PENETRATIONS IN EXCESS
OF 100 SQ. IN. IN 100 SQ. FT., ADDITIONALLY PROTECT BACK OF BOXES WITH
RATED ASSEMBLIES APPROVED BY THE AUTHORITY HAVING JURISDICTION.
15. IN SHOWER STALLS AND WALLS BEHIND PLUMBING FIXTURES, PROVIDE TILE
BACKER BOARD IN LIEU OF GYPSUM BOARD AT WALLS INDICATED TO
RECEIVE CERAMIC TILE. BACKER BOARD TO MATCH GYPSUM BOARD IN
TERMS OF THICKNESS AND FIRE-RATING CAPABILITY. PROVIDE MOISTURE
RESISTANT (MR) GYPSUM BOARD IN LIEU OF STANDARD GYPSUM BOARD AT
THE FOLLOWING LOCATIONS:
DIRECTLY BEHIND PLUMBING FIXTURES WHERE FINISH IS NOT
CERAMIC TILE AND CEILINGS ABOVE SHOWER STALLS.
16. AT NON-FIRE RATED, NON-ACOUSTIC PARTITIONS THAT DO NOT EXTEND TO
STRUCTURE ABOVE, CONTRACTOR HAS OPTION OF EXTENDING STUDS TO
STRUCTURE ABOVE OR TERMINATING STUDS 4" ABOVE HIGHEST ADJACENT
CEILING AND BRACING TOP TRACK AT INTERVALS OF 4'-0" OC (MAX) TO
STRUCTURE ABOVE.
17. WHERE STUDS EXTEND MORE THAN 3'-0" ABOVE THE TOP OF GYPSUM BOARD,
PROVIDE HORIZONTAL BRACING MIDWAY BETWEEN TOP OF GYPSUM BOARD
AND TOP OF STUDS.
18. AT FURRING PARTITIONS (GYPSUM BOARD ONE SIDE ONLY) PROVIDE
HORIZONTAL STUD BRACING OR 18 GA ANGLE CLIPS SECURED TO
STRUCTURAL SUBSTRATE AT 4'-0" OC (MAX). SIMILAR REQUIREMENT AT
COLUMN FURRING.
19. MAGNITUDE OF POTENTIAL STRUCTURAL LIVE LOAD DEFLECTION IMPACTING
PARTITIONS FOR THIS PROJECT IS 1" IN COMPRESSION AND 0" IN EXTENSION,
FOR A TOTAL MOVEMENT OF 1". FOR RATED PARTITIONS, THE HEAD-OF-WALL
FIRE RESISTIVE ASSEMBLY PROVIDED MUST BE RATED FOR THIS DEGREE OF
MOVEMENT. PROVIDE A FIRE-RESISTIVE VARIATION FOR EACH CONDITION
(BEAMS, DUCTS, CORNERS, ETC.) ENCOUNTERED AT THE RATED PARTITION
HEADS. FOR NON-RATED PARTITIONS, SECURE THE TOP TRACK IN A MANNER
THAT ACCOMMODATES DEFLECTION OF THE STRUCTURE ABOVE OR BELOW.
20. FOR DOORS, RELITES, DUCT AND OTHER OPENINGS WITH ROUGH OPENING
DIMENSIONS OF 4'-0" OR WIDER, PROVIDE HEAVY GAUGE KING STUDS AND A
"BOX BEAM" HEADER AS DETAILED IN STANDARD DOOR DETAILS.
1. EPOXY REPAIR AND REPAINT WOOD DOOR, FRAME, TRIM AND HEADER-TYP.
ALL DOORS.
2. EPOXY REPAIR AND REPAINT WOOD WINDOW UNITS, TRIM AND HEADER.
REPAIR HARDWARE AND WINDOW OPERATION. INSTALL NEW SEALANT, PUTTY
AND REPLACE BROKEN GLAZING AS REQUIRED -TYP. ALL WINDOWS.
3. EPOXY REPAIR AND REPAINT WOOD OVERHEAD DOOR TRIM AND HEADER.
PREP FOR NEW OVERHEAD DOOR AND HARDWARE-TYP. ALL DOORS.
4. INSTALL NEW CLAY TILE ROOFING TO MATCH EXISTING OVER NEW ROOF
SHEATHING AND HIGH TEMPERATURE ICE AND WATER SHIELD.
5. NEW CLAY TILE ROOFING OVER ICE AND WATER SHIELD ON 5/8" PLYWOOD
AND LIGHT GUAGE METAL TRUSSES - SEE STRUCTURAL.
6. INSTALL NEW METAL GUTTERS AND DOWNSPOUTS.
7. EPOXY REPAIR AND REPAINT WOOD SOFFITS, FACIAS, BEAM ENDS AND ALL
MISC TRIM.
8. TUCKPOINT & REPAIR ANY HOLES (WITH REMOVED BRICK) ON ALL EXISTING
BRICK WALLS AS REQUIRED. CLEAN ALL BRICK. PERFORM MOCKUP FOR ALL
BRICK REPAIR AND INSTALLATION.
9. NEW PLUMBING FIXTURES AND HVAC - SEE PLUMBING AND MECHANICAL.
10. NEW INTERIOR WALL. SEE WALL TYPES A-503.
11. NEW EXTERIOR WALL. SEE WALL TYPES A-503.
12. CLEAN AND SEAL ALL EXISTING CONCRETE FLOOR SLABS.
13. NEW CEILING - SEE REFLECTED CEILING PLANS A-102.
14. EXISTING GYPSUM BOARD CEILING TO BE CLEANED AND PAINTED.
15. OPEN TO STRUCTURE ABOVE. PRESSURE WASH GENTLY ALL WOOD
STRUCTURE TO CLEAN AND SEAL WITH A CLEAR SEALER TO PROTECT THE
WOOD. PERFORM MOCKUP IN A NON-CONSPICUOUS LOCATION.
16. NEW FIRE EXTINGUISHER AND CABINET.
17. 24" VERTICAL GRAB BAR - STAINLESS STEEL, B-5806X24.
18. 36" HORIZONTAL GRAB BAR - STAINLESS STEEL, B-5806X36.
19. 42" HORIZONTAL GRAB BAR - STAINLESS STEEL, B-5806X42.
20. FIBERGLASS SHOWER UNIT (ADA ACCESSIBLE) W/ CURTAIN ROD, B-4207X60,
21. SHOWER SEAT, B-51815.
22. 12"X18"X72" SINGLE TIER METAL LOCKERS, ULINE H-1226.
23. TOILET TISSUE DISPENSER - STAINLESS STEEL, DOUBLE ROLL W/
CONTROLLED DELIVERY B-274.
24. ELECTRIC HAND DRYER - STAINLESS STEEL, SURFACE MTD QUIET B-7128.
25. HAND SOAP DISPENSER - STAINLESS STEEL, SURFACE MTD B-40.
26. ROBE HOOKS - STAINLESS STEEL, B-671.
27. 24"X36" STAINLESS STEEL FRAMED MIRROR, SURFACE MTD B-1659.
28. VANITY COUNTERTOP AND BACKSPLASH, SOLID COMPOSITE - SEE C3/A-501.
29. 9"X36" WOOD LOCKERROOM BENCH, ULINE H-3640ST.
30. WALL MOUNTED PRIVACY PANEL, SOLID COMPOSITE SIERRA SERIES 1095.
31. CEILING MOUNTED TOILET PARTITION, SOLID COMPOSITE SIERRA SERIES 1095.
32. 12"X34" STAINLESS STEEL SHELF / MOP RACK, B-239X34.
33. PREMAUFACTURED CASEWORK.
34. DISH WASHER - STAINLESS STEEL - PROVIDED BY NCA.
35. REFRIGERATOR - STAINLESS STEEL - PROVIDED BY NCA.
36. MICROWAVE - STAINLESS STEEL - PROVIDED BY NCA.
37. KITCHEN SOLID SURFACE COUNTERTOP AND 4" BACKSPLASH.
38. NEW CONCRETE FOUNDATION, RETAINING WALL, FOOTING AND SLAB - SEE
STRUCTURAL.
39. EXISTING CONCRETE FOUNDATION AND FOOTING.
40. NEW 5/8" GYPSUM BOARD CEILING ON BOTTOM OF TRUSSES. TAPE - 3 COATS,
SAND, FLAT TEXTURE, PAINT - 2 COATS.
41. 2X2 SUSPENDED ACCOUSTIC TILE CEILING.
42. WASH RACK: MI-T-M CORP., CAW ALUMINUM SERIES INDUSTRIAL COLD WATER
PRESSURE WASHER, COLD WATER, ELECTRIC, WALL MOUNT, DIRECT DRIVE,
CAW-3004-OME1, 3000 PSI - OR APPROVED EQUAL.
43. SHOWER / EYEWASH - SEE PLUMBING.
44. INSTALL NEW WOOD TRIM TO MATCH EXISTING AND INSTALL NEW OVERHEAD
DOOR.
45. VEHICLE LIFT: BENDPAK XPR-18CL-192, 18,000 LBS - OR APPROVED EQUAL.
46. TIRE CHANGER: WEAVER W-898XS - OR APPROVED EQUAL.
47. AIR COMPRESSOR: INGERSOLL RAND ROTARY SCREW, HORIZONTAL, 7 1/2 HP,
26.3 CFM, 80 GAL TANK, 230V AC - OR APPROVED EQUAL.
48. NEW ALUMINUM WINDOW - SEE WINDOW TYPES A-502.
49. REMOVE ALL OLD ROOFING REMANENCE AND COVER OVER WOOD HEADER.
EPOXY REPAIR HEADER AND PAINT.
(NOT ALL KEYED NOTES USED ON THIS
SHEET)REMODEL KEYED NOTES:
1. ALL SPECIALTY EQUIPMENT TO BE BOBRICK OR EQUAL.
2. ADD WOOD BLOCKING FOR ALL TOILET ROOM SPECIALTIES AND WOOD
CASEWORK.
GENERAL NOTES:
SYMBOLOGY LEGEND
Sheet Type Designator
1AS601 SHEET No.
SHEET NUMBER
Level 2 Designator
Sheet SequenceBuilding Number
Discipline Designator
NORTH ARROW
N
PLAN OR DETAIL CALLOUT
PLAN OR DETAIL TITLE
TITLE ON SHEET
SCALE: 1/8" = 1'-0"XX.X
PLAN OR DETAIL TITLE
GRAPHIC SCALE
0' 2' 4' 8' 16'
1/4"=1'-0"
F1
A-201
DETAIL SECTION NUMBER
SHEET ON WHICH
SECTION IS
DRAWN
DETAIL CALLOUT REFERENCE
A
GRID BUBBLES
ALUMINUM
NBBJ_Aluminum (from Aluminum)
CONCRETE
NBBJ_Concrete ( from concrete)
GLASS
NBBJ_Glass
RIGID INSULATION
NBBJ_Rigid_Insulatio n
BRICK IN SECTION
NBBJ_Brick_Section
CONCRETE MASONRY
UNIT
NBBJ_CMU_Section
EARTH
NBBJ_Earth (from Earth 2)
GYPSUM / PLASTER
NBBJ_Gypsum (from Gypsum-Plaster)
STEEL
NBBJ_Steel (from Steel 2)
PEA GRAVEL
NBBJ_Gravel (from Gravel 2)
STONE
NBBJ_Stone (from Stone 2)
BATT INSULATION
Detail Element - Insulation
PRECAST
NBBJ_Precast (from concrete_light)
SAND
NBBJ_Sand
WOOD - SOLID
NBBJ_Wood 1
PLYWOOD
NBBJ_Plywood
CONTINUOUS BLOCKING
SHIM
MATERIALS LEGEND
GRASS
NBBJ_Grass
CAST STONE
NBBJ_Cast Stone (from Fleks)
4' - 0"
5' - 0"
5' - 0"
1' - 4"
/2
VA BARRIER FREE DESIGN STANDARD
MINIMUIM REQUIREMENTS
BA
C
K W
AL
L
F.F.
SI
D
E W
AL
L
SI
D
E W
AL
L
TO
IL
ET
R
O O
M
3' - 2"
1'
8"
2'
TYP GRAB BAR
10 28 00
GB & GB-MH
REF DTL B1/0AI506
TOILET PAPER DISP
10 28 00
TPD-1
SURFACE MTD
SHOWER CURTAIN ROD
10 28 00
SR-1
MIRROR
10 28 00
MR-4
REF DTL C6/0AI536
1' - 7" 1' - 7"
TPD
SN
(WMS
ONLY)
TYPICAL TOILET DEVICES
TPD & SN
(SIDEWALL ELEVATION)
TOILET
PARTITIO
N
(WHERE
OCCURS)
HAND DRYER
10 28 00
HD-1
SURFACE MTD
TYPICAL HC TOILET DEVICES
TPD, SN & GB
(SIDEWALL ELEVATION)
10 28 00
REF DTL B1/0AI506
2'
7/
8"
1' - 7" 1' - 7"
M
IN
1'
8"
1' - 0"
M
IN
1'
7/
8"
1'
7/
8"
TPD
SN
(WMS ONLY)
TOILET
PARTITION
(WHERE
OCCURS)
ALIGN
42" GRAB
BAR
3'
3"
SOAP DISP
SD-3
RECESSED
COAT HOOK
10 28 00
CH-1
SURFACE MTD
CENTER
ON LAV,
UNO
HIGH
MEDIUM
LOW
NOTE: ALIGN
LOW / HIGH DEVICES
AT CENTER LINE,
TYP. THROUGHOUT
WHERE DEVICES ARE
IN CLOSE PROXIMITY
NOTE: ALIGN
DEVICES AT BOTTOM,
TYP. THROUGHOUT WHERE DEVICES
ARE IN CLOSE PROXIMITYF.F.
DEVICE PROXIMITY GUIDELINES
6'
9"
HC URINAL
DIV 22
(BACKWALL ELEVATION)
TYP URINAL
15" CLEAR 15" CLEAR
3'
8"
4'
6"
SCD
(WHERE
OCCURS)
EQ EQ
SCD
(WHERE
OCCURS)
TOILET
PARTITION
SI
D
EW
AL
L
TYPICAL TOILET DEVICES
SCD & GB
(BACKWALL ELEVATION)
10 28 00
REF DTL B1/0AI506
TYPICAL TOILET STALL DEVICES
SCD
(BACKWALL ELEVATION)
2'
0"
1'
5"
FINISH FLOOR
BASE
FLOORING BASE
REFER TO FINISH SCHEDULE
FOR TYPE AND HEIGHT
3'
4"
CORNER GUARD
6'
8"
HC SHOWER
HEAD/CONTROL
7" 9"
3'
2" M
IN
WALL @
OPEN SIDE
OF SHOWER
1' - 0" 2' - 0"
4'
0" M
AX
9"
1' - 6" 1' - 6"
F.F.
TO
IL
ET
R
O O
M
C
LI
N
IC
AL
M
IS
C
EL
LA
N
EO
U S
3'
6"
C/L
D U
PL
EX
Q U
AD
VO
IC
E
/ D
AT
A C
AB
LE
BE
D
SW
IT
C H
TH
ER
M O
ST
AT
FI
R
E
AL
AR
M
P U
LL
1' - 3"
REFER TO FINISH
SCHEDULE FOR
DECORATIVE FINISH
THICKNESS ACCOUNTED
FOR IN CLEAR DIM.
REFER TO FIXTURE
SCHEDULE FOR LAV
TYPES AND DETAILS
SOAP DISPENSER
2' - 0"
1' - 5"
MIN.
8"
6" MAX.
REFER TO FINISH
SCHEDULE FOR
DECORATIVE FINISH
THICKNESS
ACCOUNTED FOR
IN CLEAR DIM.
REFER TO TA SCHEDULE
FOR MIRROR TYPES
PAPER
TOWEL
DISPENSER
3'
3"
2' -1
0" M
AX
2' -5
" M
IN
2' -3
" M
IN
TYPICAL LAV
MR, SD & PTD
(BACKWALL ELEVATION)
TYPICAL LAV
(SIDEWALL ELEVATION)
30" x 48" CLEAR FLOOR
SPACE REQUIRED
FOLD DOWN
BENCH
10 28 00
REF DTL B5/0AI536
D U
PL
EX
Q U
AD
VO
IC
E
/ D
AT
A
" S
U R
FA
C
E
3'
6"
1'
6"
SW
IT
C H
(D O
U
BL
E)
4'
0"
FI
R
E H
O R
N
6'
8"
6'
6" M
AX
GENERAL WALL DEVICES
DIV 23, 26, 72 & 28
ELECTRICAL PANEL
DIV 26
DOOR OPERATOR
CARD READER
DIV 08
DP-OP-CR
ALCOVE WALL
HC DRINKING FOUNTAIN
DIV 22
EQ. EQ.
2' -1
0" M
AX
2' -5
" M
IN
ALIGN BOTTOM OF
MIR, SD, AND PTD
W
AL
L
PH
O N
E
FIRE EXTINGUISHER CAB
10 44 13
FEC
TO
P
O F
EX
TI
N G
'R
- 0
" M
AX
2'
3"
HANDRAIL
WHERE OCCURS
W
AL
L
PH
O N
E
JA
C K
4'
1/
2"
1'
6"
1' - 10"
CORNER OR EDGE
OF WALL
OR CENTER ON WALL
6' WIDE OR LESS
0V
R
EC
EP
TA
C
LE
4" 6"
1'
6"
EM
ER
G
EN
C Y
PO
W
ER
O
FF
EPOSW
IT
C H
2'
ALIGN
UC LIGHT SWITCH
LOCATION AT SIDE WALL
REF CODED NOTE 254
WALL
CABINET
BASE
CABINET
D U
PL
EX
4"
THERMOSTAT
AT EDGE OF
WALL OR CORNER
4"
4"4" 4"
M
IS
C
EL
LA
N
EO
U
S
TYPICAL HK CLOSET
DSP0302
(SIDEWALL ELEVATION - 2)
TYPICAL DEVICE LOCATION AT DOOR TYPICAL SIGNAGE /
STROBE AT DOOR
5'
0" 6'
8"
CHEM DISPENSER
4'
2' - 4"
3'
0"
EQ EQ
5" 5" 6" 6" 4" 4" 7" 1' - 0"
SHIFT DEVICES TOWARD
DOOR FRAME WHERE ALL
DEVICES DO NOT OCCUR
ALIGN TOP OF ALL DEVICES,
TYP IN ALL LOCATIONS
ALIGN TOP OF CLOCK
WITH TOP OF DOOR
CLOCK
FURN REPORT
CLOCK-1, CLOCK-2
7'
2"
4'
6"
HOUSEKEEPING
CLOSET COAT HOOKS
FIRE ALARM PULL
AT DOOR
4'
0"
F
4"
B-290 2436
MOUNTING HEIGHTS LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI
Project Management
Construction Management
Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
S
EA
N
M. F ITZPATR
IC
K
C U s e rs \D a n ia H a b b o u b
\V a li C o o p e r
In te rn a ti o n a l\ V
A N
C A
L A
N C
G ra v e s it e E x p a n s io n
C o lu m b a ri u m
D o c u m e n ts
\a W o rk
F ile s
M a in te n a n c e
\7
B id
D o c s
R e v is io n s f o r S in g le
P ro je c t B id
.1
.2
\1
P la n s \C
A D
\L A
N C
C
M
M a in t_ A rc h it e c tu ra l.
rv t
/5 /2
:1
:1
A M
A-001
ARCHITECTURAL LEGENDS AND
NOTES
23Revisions: Date:
IRB
C1
A-2
L
M0' - 4"
6' - 9"
N
O
P
Q
B1
A-2
D
A -201
D 4A -201
F
A -201
F 3A -201
F1
A-2
B1
A-2
D
A -202
F 6A -201
A
B
C
D
E
F
8 G
H
I
J
K
A-4
A-4
A-4
A-4
FIN GRADE
T/FTG
PER PLAN
T/SLAB
PER PLAN
PER PLAN
P E
R P
L A
N
C
L R
C
L R
(2) #5 T&B CONT
(2) #4 IN BOND BEAM
AT TOP & BOT COURSE
1" STUCCO -PAINTED
1" STUCCO -PAINTED
CMU CAP
CMU WALL &
REINF PER PLAN
L A
P P
E R
/S
-3
8" CONC STEM WALL
W/ (3) #5 HORIZ
CONF FTG PER PLAN
#5 T&B @ 16" OC
DOWEL W/ STD HOOK
TO MATCH VERT REINF
(ALT HOOKS)
HOLLOW SQUARE STEEL BAR
2" x 2" x 1/4" TS
END OF WALL NOTE:
PROVIDE 3/4" GAP BETWEEN END OF WALLS
AND BUILDINGS. INSTALL BACKERROD AND
SEALANT ON EACH SIDE OF THE WALL
HOLLOW SQUARE STEEL BARS
1" x 1" x 1/4" TS @ 6" O.C. -PAINTED
HOLLOW SQUARE STEEL BAR
2" x 2" x 1/4" TS -PAINTED
/2
/2
6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI
Project Management
Construction Management
Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
S
EA
N
M. F ITZPATR
IC
K
C U s e rs \D a n ia H a b b o u b
\V a li C o o p e r
In te rn a ti o n a l\ V
A N
C A
L A
N C
G ra v e s it e E x p a n s io n
C o lu m b a ri u m
D o c u m e n ts
\a W o rk
F ile s
M a in te n a n c e
\7
B id
D o c s
R e v is io n s f o r S in g le
P ro je c t B id
.1
.2
\1
P la n s \C
A D
\L A
N C
C
M
M a in t_ A rc h it e c tu ra l.
rv t
/5 /2
:1
:1
A M
A-101
ARCHITECTURAL SITE PLAN
3/32" = 1'-0" F5
Site Plan
New concrete slab and sand/oil separator
Renovated brick storage building
New administration building
New maintenance building
New covered vehicle storage building
New privacy wall
SEE D2&F2/A-101
New privacy wall
SEE D2&F2/A-101
New retaining walls
Extended employee parking
N
Vehicle Parking
Fuel Tank
FITZ TM
1" = 1'-0" F2
CMU / METAL PRIVACY WALL DETAIL
1/2" = 1'-0" D2
FENCE ELEV. DETAIL
A. PROVIDE FULL -SCALE MOCKUPS. MOCKUPS SHALL REPRESENT THE FOUNDATIONS,
BRICK VENEER, RANGE OF COLORS, TEXTURES, CUTS, FINISHES, ANCHORING,
HARDWARE, GROUT, SEALANTS AND ALL SETTING METHODS.
MOCKUPS ARE TO BE PERFORMED FOR EXTERIOR WALLS AND BRICKWORK, DOOR AND
WINDOW REFURBISHING, DOOR AND WINDOW HARDWARE REFURBISHING, WOOD TRIM
REPAIR, BRICK REPAIR, EXPOSED WOOD CLEANING AND SEALING AND CLAY TILE
ROOFING.
B. SEE SPECIFICATIONS FOR ADDITIONAL MOCKUP REQUIREMENTS.
C. MOCKUPS SHALL BE ERECTED IN LOCATION AND ORIENTATION APPROVED BY THE
COR AND SHALL BE ERECTED BY THE SAME TEAM THAT WILL INSTALL ALL ITEMS FOR
THE PROJECT.
D. MOCKUPS SHALL BE MINIMUM OF 5'X5'.
E. IN SITU MOCKUPS ARE EXPRESSELY PROHIBITED.
F. COMPLETED MOCKUPS SHALL BE INSPECTED AND APPROVED BY THE COR BEFORE
CONSTRUCTION.
G. APPROVED MOCKUPS SHALL BECOME THE STANDARD OF WORKMANSHIP AND
APPEARANCE FOR THE PROJECT. ALL ITEMS INSTALLED FOR THIS PROJECT SHALL
MATCH THE APPROVED MOCKUPS.
H. ANY ITEM INSTALLED THAT DOES NOT (AS DETERMINED BY THE COR) MATCH THE
APPROVED MOCKUP SHALL BE CONSIDERED AUTOMATICALLY REJECTED BY THE NCA
AND SHALL BE IMMEDIATELY REMOVED FROM THE PROJECT SITE AND REPLACED BY
THE CONTRACTOR AT NO COST TO THE GOVERNMENT.
I. MOCKUPS SHALL BE COMPLETE IN ALL RESPECTS AND SHALL REPRESENT THE FINAL
COMPLETE ASSEMBLIES FOR ALL CONDITIONS.
J. USE MOCKUPS TO TEST CLEANING METHODS.
K. WHERE REVIEW OF MOCKUPS MAY REQUIRE REVISIONS OF DESIGNS OR
CONSTRUCTION TECHNIQUES, THE COR WILL PROVIDE SUCH REVISIONS IN WRITING.
SUCH REVISIONS WILL BE COMPLETED AND FINAL APPROVAL OF ALL ASPECTS OF THE
MOCKUP SHALL BE ACHIEVED PRIOR TO CONSTRUCTION BEGINNING FOR THE FINISHED
PROJECT.
L. DO NOT INSTALL MOCKUP COMPONENTS OR MATERIALS IN THE COMPLETD
PROJECT.
M. MOCKUPS SHALL REMAIN IN PLACE UNTIL THE PROJECT IS COMPLETE AND
ACCEPTED BY THE NCA AFTER FINAL INSPECTION. AFTERWARD, REMOVE AND
DISPOSE OF MOCKUPS.
MOCKUP REQUIREMENTS
FD
FD
FD
FD
FD
C
A -2
Headstone & Marker Storage
Workshop - C, W, P, E
Equipment Storage
Storage
301 Irrigation Storage and Office
305304303
L M N O P Q
B
A -2
D1
A-201
D4
A-201F1
A-201
F3
A-201
E1
A-301
F1
A-301
C1
A-301
B1
A-301
Break / Conf
Office
Map
Foreman
Secure Storage /
IT
Mech / Elec
Lockers
Womens
Mens
H.K.
1 1 1 1 1 2 2
G H I J K
70' - 0"
12' - 8" 19' - 0" 16' - 4" 22' - 0"
A-401
D2
A -4
A -4
A-401
F2
A -4
A -4
8' - 7" 3' - 11" 8' - 6" 2' - 1" 3' - 8" 3' - 8" 5' - 9" 11' - 4" 4' - 11"4' - 1" 6' - 7" 6' - 11"
3' - 11" 8' - 6" 6' - 7" 10' - 7" 5' - 9" 14' - 1" 7' - 11"
9' - 6"
2' - 8" 7' - 5"
44 3 3
2 2 2 2
7' - 1" 10' - 6" 1' - 11" 10' - 3" 2' - 6 1/2" 9' - 9" 5' - 9" 6' - 6" 9' - 8" 4' - 0"
2' - 5" 2' - 11" 1' - 9"
5' - 3" 1' - 10" 5' - 7" 4' - 11 1/2" 1' - 11" 6' - 5 1/2" 6' - 4" 8' - 1" 7' - 5" 8' - 1" 8' - 1"
Routine Maint Bay
Heavy Maint Bay
Hazardous Materials &
Pesticide Storage
200 202
F1
A-202
F
A -2
D1
A-302
B1
A-302
A B C D
E
57' - 0"
20' - 6" 28' - 6" 8' - 0"
46 47
Covered Parking
B1
A-202
D
A -2
F1
A-302
D
E F
22' - 0"
ARCH. LEGEND
NOTE: NOT ALL SYMBOLS USED
0 COLUMN NUMBER / GRID LINE
CENTER LINE
x'- x"
DIMENSION LINE
EXISTING TO BE REMOVED
EXISTING TO REMAIN
EXISTING TO REMAIN
NEW CONSTRUCTION
ROOM NAME
ROOM NAME
ROOM NUMBER
DOOR NUMBER SYMBOL
XX
X-XXX
1 Ref
1 A101
1 Ref
SHEET DETAIL IS DRAWN ON
DETAIL NUMBER
DETAIL NUMBER
ARCHITECTURAL ELEVATION
SHEET NUMBER
DETAIL NUMBER
X
X-XXX
SHEET NUMBER
ARCHITECTURAL SECTION
1i WINDOW TYPE
R e f
R e f
WALL TYPE#
5/8" GYPSUM BOARD - TYPE X
2' X 2' ACOUSTIC CEILING
1. EPOXY REPAIR AND REPAINT WOOD DOOR, FRAME, TRIM AND HEADER-TYP.
ALL DOORS.
2. EPOXY REPAIR AND REPAINT WOOD WINDOW UNITS, TRIM AND HEADER.
REPAIR HARDWARE AND WINDOW OPERATION. INSTALL NEW SEALANT, PUTTY
AND REPLACE BROKEN GLAZING AS REQUIRED -TYP. ALL WINDOWS.
3. EPOXY REPAIR AND REPAINT WOOD OVERHEAD DOOR TRIM AND HEADER.
PREP FOR NEW OVERHEAD DOOR AND HARDWARE-TYP. ALL DOORS.
4. INSTALL NEW CLAY TILE ROOFING TO MATCH EXISTING OVER NEW ROOF
SHEATHING AND HIGH TEMPERATURE ICE AND WATER SHIELD.
5. NEW CLAY TILE ROOFING OVER ICE AND WATER SHIELD ON 5/8" PLYWOOD
AND LIGHT GUAGE METAL TRUSSES - SEE STRUCTURAL.
6. INSTALL NEW METAL GUTTERS AND DOWNSPOUTS.
7. EPOXY REPAIR AND REPAINT WOOD SOFFITS, FACIAS, BEAM ENDS AND ALL
MISC TRIM.
8. TUCKPOINT & REPAIR ANY HOLES (WITH REMOVED BRICK) ON ALL EXISTING
BRICK WALLS AS REQUIRED. CLEAN ALL BRICK. PERFORM MOCKUP FOR ALL
BRICK REPAIR AND INSTALLATION.
9. NEW PLUMBING FIXTURES AND HVAC - SEE PLUMBING AND MECHANICAL.
10. NEW INTERIOR WALL. SEE WALL TYPES A-503.
11. NEW EXTERIOR WALL. SEE WALL TYPES A-503.
12. CLEAN AND SEAL ALL EXISTING CONCRETE FLOOR SLABS.
13. NEW CEILING - SEE REFLECTED CEILING PLANS A-102.
14. EXISTING GYPSUM BOARD CEILING TO BE CLEANED AND PAINTED.
15. OPEN TO STRUCTURE ABOVE. PRESSURE WASH GENTLY ALL WOOD
STRUCTURE TO CLEAN AND SEAL WITH A CLEAR SEALER TO PROTECT THE
WOOD. PERFORM MOCKUP IN A NON-CONSPICUOUS LOCATION.
16. NEW FIRE EXTINGUISHER AND CABINET.
17. 24" VERTICAL GRAB BAR - STAINLESS STEEL, B-5806X24.
18. 36" HORIZONTAL GRAB BAR - STAINLESS STEEL, B-5806X36.
19. 42" HORIZONTAL GRAB BAR - STAINLESS STEEL, B-5806X42.
20. FIBERGLASS SHOWER UNIT (ADA ACCESSIBLE) W/ CURTAIN ROD, B-4207X60,
21. SHOWER SEAT, B-51815.
22. 12"X18"X72" SINGLE TIER METAL LOCKERS, ULINE H-1226.
23. TOILET TISSUE DISPENSER - STAINLESS STEEL, DOUBLE ROLL W/
CONTROLLED DELIVERY B-274.
24. ELECTRIC HAND DRYER - STAINLESS STEEL, SURFACE MTD QUIET B-7128.
25. HAND SOAP DISPENSER - STAINLESS STEEL, SURFACE MTD B-40.
26. ROBE HOOKS - STAINLESS STEEL, B-671.
27. 24"X36" STAINLESS STEEL FRAMED MIRROR, SURFACE MTD B-1659.
28. VANITY COUNTERTOP AND BACKSPLASH, SOLID COMPOSITE - SEE C3/A-501.
29. 9"X36" WOOD LOCKERROOM BENCH, ULINE H-3640ST.
30. WALL MOUNTED PRIVACY PANEL, SOLID COMPOSITE SIERRA SERIES 1095.
31. CEILING MOUNTED TOILET PARTITION, SOLID COMPOSITE SIERRA SERIES 1095.
32. 12"X34" STAINLESS STEEL SHELF / MOP RACK, B-239X34.
33. PREMAUFACTURED CASEWORK.
34. DISH WASHER - STAINLESS STEEL - PROVIDED BY NCA.
35. REFRIGERATOR - STAINLESS STEEL - PROVIDED BY NCA.
36. MICROWAVE - STAINLESS STEEL - PROVIDED BY NCA.
37. KITCHEN SOLID SURFACE COUNTERTOP AND 4" BACKSPLASH.
38. NEW CONCRETE FOUNDATION, RETAINING WALL, FOOTING AND SLAB - SEE
STRUCTURAL.
39. EXISTING CONCRETE FOUNDATION AND FOOTING.
40. NEW 5/8" GYPSUM BOARD CEILING ON BOTTOM OF TRUSSES. TAPE - 3 COATS,
SAND, FLAT TEXTURE, PAINT - 2 COATS.
41. 2X2 SUSPENDED ACCOUSTIC TILE CEILING.
42. WASH RACK: MI-T-M CORP., CAW ALUMINUM SERIES INDUSTRIAL COLD WATER
PRESSURE WASHER, COLD WATER, ELECTRIC, WALL MOUNT, DIRECT DRIVE,
CAW-3004-OME1, 3000 PSI - OR APPROVED EQUAL.
43. SHOWER / EYEWASH - SEE PLUMBING.
44. INSTALL NEW WOOD TRIM TO MATCH EXISTING AND INSTALL NEW OVERHEAD
DOOR.
45. VEHICLE LIFT: BENDPAK XPR-18CL-192, 18,000 LBS - OR APPROVED EQUAL.
46. TIRE CHANGER: WEAVER W-898XS - OR APPROVED EQUAL.
47. AIR COMPRESSOR: INGERSOLL RAND ROTARY SCREW, HORIZONTAL, 7 1/2 HP,
26.3 CFM, 80 GAL TANK, 230V AC - OR APPROVED EQUAL.
48. NEW ALUMINUM WINDOW - SEE WINDOW TYPES A-502.
49. REMOVE ALL OLD ROOFING REMANENCE AND COVER OVER WOOD HEADER.
EPOXY REPAIR HEADER AND PAINT.
(NOT ALL KEYED NOTES USED ON THIS
SHEET)REMODEL KEYED NOTES:
1. ALL SPECIALTY EQUIPMENT TO BE BOBRICK OR EQUAL.
2. ADD WOOD BLOCKING FOR ALL TOILET ROOM SPECIALTIES AND WOOD
CASEWORK.
GENERAL NOTES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI
Project Management
Construction Management
Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
S
EA
N
M. F ITZPATR
IC
K
C U s e rs \D a n ia H a b b o u b
\V a li C o o p e r
In te rn a ti o n a l\ V
A N
C A
L A
N C
G ra v e s it e E x p a n s io n
C o lu m b a ri u m
D o c u m e n ts
\a W o rk
F ile s
M a in te n a n c e
\7
B id
D o c s
R e v is io n s f o r S in g le
P ro je c t B id
.1
.2
\1
P la n s \C
A D
\L A
N C
C
M
M a in t_ A rc h it e c tu ra l.
rv t
/5 /2
:1
:2
A M
A-102
MAIN FLOOR PLANS
1/4" = 1'-0" B5
Administration & Storage Building Floor Plans
1/4" = 1'-0" F2
Maintenance Building Floor Plan 1/4" = 1'-0"
F6 Covered Parking Floor Plan
N
0' 2' 4' 8' 16'
1/4"=1'-0"
File details come from the government source that posted it. Updated .