250508 Los Angeles CA 898-034 Maintenance Plans 1 of 10.pdf
PDF 9 MB Posted
- Attached to
- Y1EB--Los Angeles National Cemetery construct a new Maintenance Complex and Corrects FCA Deficie
- Solicitation number
- 36C78625B0024
About this file
These documents are architectural and engineering plans for the construction of a new Maintenance Facility at the Los Angeles National Cemetery, with project number 898CM3034. The comprehensive set of 95 sheets includes detailed site plans, erosion control strategies, topographic surveys, and specifications for various building components. Key project elements include constructing an administration and storage building, maintenance building, covered storage area, and associated site improvements.
The plans outline specific requirements for the temporary maintenance yard, such as installing a 24' x 60' office trailer, two 40' workshop conexes with power and lighting, a three-station restroom/shower trailer, diesel storage tank, hazardous materials storage, and a main electrical panel. The project documents emphasize strict site management protocols, including coordinating burial ceremonies, maintaining a clean work environment, adhering to cemetery decorum, and implementing comprehensive erosion and dust control measures. The project is being managed by the Department of Veterans Affairs National Cemetery Administration, with design work by Vali Cooper International and various engineering consultants.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
SHEET
NO.
DRAWING NO. SHEET TITLE
PROJECT TEAM
SITE LOCATION MAP
SCALE: NTS N
SITE LOCATION AND ACCESS MAP
SCALE: NTS N
LOS ANGELES NC
LOS ANGELES NC
MAINTENANCE YARD
ARCHITECT / ENGINEER
VALI COOPER INTERNATIONAL, LLC
COVINGTON, LA 70433
CONTACT: SEAN FITZPATRICK
SEAN@VALIINT.COM
504-378-7399
SITE OWNER
VA NCA
LOS ANGELES NATIONAL CEMETERY
CONTACT: JUAN KAYS
JUAN.KAYS@VA.GOV
202-632-5057
SURVEYOR
ATC DESIGN GROUP
ESCONDIDO, CA 92029
CONTACT: RYAN POST
RPOST@ATCDESIGNGROUP.COM
760-738-8800
HAZARDOUS MATERIALS
TERRACON
TUSTIN, CA 92750
CONTACT: VICTOR NGUYEN
VICTOR.NGUYEN@TERRACON.COM
310-627-3430
STRUCTURAL
DCI
Los Angeles, CA 90049
CONTACT: NOLAN LENAHAN
NLENAHAN@DCI-ENGINEERS.COM
213-298-3700
DEPARTMENT OF VETERANS AFFAIRS
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
NCA PROJECT NO. 898CM3034
Los Angeles, CA
G-001 COVER SHEET
G-101 SITE ACCESS, FENCING AND STAGING PLAN
GC101 EROSION AND SEDIMENTATION CONTROL PLAN
V-101 TOPOGRAPHIC SURVEY
CD101 DEMOLITION PLAN - SITE
CD102 DEMOLITION PLAN - UTILITIES
C-101 SITE PLAN
C-102 UTILITY PLAN
C-103 GRADING PLAN
C-104 JOINTING PLAN
C-201 STORM DRAINAGE PROFILES
C-202 SANITARY SEWER PROFILES
C-501 DETAILS - SITE
C-502 DETAILS - UTILITIES
C-503 DETAILS - UTILITIES
C-504 DETAILS - EROSION AND SEDIMENTATION CONTROL
LD101 IRRIGATION DEMOLITION PLAN
LI101 IRRIGATION PLAN
LI501 IRRIGATION & PLANTING DETAILS
LP101 PLANTING PLAN
D-101 SITE & BUILDING DEMOLITION PLAN
D-102 DEMOLITION DETAILS
A-001 ARCHITECTURAL LEGENDS AND NOTES
A-101 ARCHITECTURAL SITE PLAN
A-102 MAIN FLOOR PLANS
A-103 REFLECTED CEILING PLANS
A-104 ROOF PLANS
A-201 ADMINISTRATION & STORAGE BUILDING EXTERIOR ELEVATIONS
A-202 MAINTENANCE & COVERED STORAGE EXTERIOR ELEVATIONS
A-301 ADMINISTRATION & STORAGE BUILDING & WALL SECTIONS
A-302 MAINTENANCE & COVERED STORAGE BUILDING & WALL SECTIONS
A-401 ENLARGED PLANS & INTERIOR ELEVATIONS
A-501 INTERIOR DETAILS
A-502 DOOR & WINDOW DETAILS
A-503 MISC. DETAILS
S-001 GENERAL NOTES
S-002 GENERAL NOTES
S-003 SPECIAL INSPECTIONS AND ABBREVIATIONS
S-101 SITE OVERALL PLAN
S-102 ADMINISTRATION AND STORAGE BUILDING FOUNDATION PLAN
S-103 ADMINISTRATION AND STORAGE ROOF FRAMING PLAN
S-104 MAINTENANCE BUILDING AND COVERED PARKING FOUNDATION PLAN
S-105 MAINTENANCE BUILDING AND COVERED PARKING ROOF FRAMING PLAN
S-501 STRUCTURAL - FOUNDATION DETAILS
S-502 STRUCTURAL - FOUNDATION DETAILS
S-503 STRUCTURAL - CMU FRAMING DETAILS
S-504 STRUCTURAL - CFS FRAMING DETAILS
S-505 STRUCTURAL - CFS FRAMING DETAILS
S-506 STRUCTURAL - FRAMING DETAILS
S-507 STRUCTURAL - FRAMING DETAILS
S-508 STRUCTURAL - FRAMING DETAILS
M-001 MECHANICAL SYMBOLS & ABBREVIATIONS
MH101 HVAC FLOOR PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
P-001 PLUMBING SYMBOLS & ABBREVIATIONS
P-101 PLUMBING FLOOR PLANS
P-102 PLUMBING FLOOR PLANS
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
E-001 MEDIUM VOLTAGE POWER PLAN LAYOUT
E-002 ONELINE DIAGRAMS
E-003 POWER PLAN ONELINE AND PANEL LAYOUT
E-004 ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
EL101 OVERALL LIGHTING PLAN LAYOUT
EL102 STORAGE BUILDING LIGHTING LAYOUT
EL103 ADMINISTRATION BUILDING LIGHTING LAYOUT
EL104 MAINTENANCE BUILDING LIGHTING LAYOUT
EL601 LIGHTING SCHEDULE
EP101 OVERALL POWER PLAN
EP102 STORAGE BUILDING POWER LAYOUT
EP103 ADMINISTRATION BUILDING POWER LAYOUT
EP104 MAINTENANCE BUILDING POWER LAYOUT
EP105 ADMINISTRATION BUILDING ENLARGED PLAN AND SECTION VIEW
EP106 ADMINISTRATION BUILDING ELECTRICAL SECTION VIEWS
EP107 ELECTRIC DETAILS
EP601 PANEL A SCHEDULE
EP602 PANEL A-1 SCHEDULE
EP603 PANEL A-2 SCHEDULE
EP604 PANEL B SCHEDULE
EP605 PANEL C SCHEDULE
EP606 PANEL C-1 SCHEDULE
T-101 SECURITY CONTROL - PLAN LAYOUT
T-102 SECURITY CONTROL - KEYLESS ENTRY DETAILS
T-103 INFORMATION TECHNOLOGY (IT) LAYOUT
T-104 INFORMATION TECHNOLOGY (IT)
T-105 INFORMATION TECHNOLOGY (IT)
T-106 INFORMATION TECHNOLOGY (IT)
T-107 DETAILS FOR 12RU SECONDARY ENCLOSURE
T-108 BONDING FOR COMMUNICATION
T-109 WALL-MOUNT CABINET SPECS
HD101 HAZMAT DEMOLITION PLAN
HD901 HAZMAT DEMOLITION PHOTOS, MAINT. STORAGE BUILDING
HD902 HAZMAT DEMOLITION PHOTOS, MAINT. ADMIN. BUILDING & YARD
ELECTRICAL / TELECOMMUNICATIONS
JD ENGINEERING
HAMILTON, MT 59840
CONTACT: SCOTT TURNER
SCOTT & JDENG.ORG
206-218-9980
1. BURIAL CEREMONIES WILL BE SCHEDULED THROUGHOUT THE COURSE OF THIS PROJECT.
COORDINATE DAILY ACTIVITIES WITH THE CEMETERY DIRECTOR OR HIS APPROVED REPRESENTATIVE TO ACCOMMODATE SCHEDULED BURIALS (COLUMBARIUM WALLS). CONTRACTOR SHALL OBTAIN THE SCHEDULE FOR THE NEXT DAY SERVICES PRIOR TO THE CLOSE OF BUSINESS EACH DAY. ALLOWABLE
WORK TO BE DETERMINED BY THE CEMETERY DIRECTOR.
2. BECAUSE OF THE SENSITIVE NATURE OF THE CEMETERY SITE, CONTRACTOR SHALL MAINTAIN EACH
WORK AREA IN A CLEAN AND ORDERLY APPEARANCE. TRASH AND WASTE MATERIALS SHALL BE
STORED IN APPROVED CONTAINERS AND ROUTINELY DISPOSED OFF-SITE. CLEANUP SHALL BE
REQUIRED AT THE END OF EACH DAY AND/OR MORE FREQUENTLY AS REQUIRED.
3. THE CONTRACTORS STAFF AND SUBCONTRACTORS STAFF SHALL NOT:
DRESS IN SLEEVELESS SHIRTS OR SHORT PANTS, WEAR CLOTHING WITH INAPPROPRIATE LOGOS, PLAY MUSIC, TALK LOUD, PLACE PERSONAL ITEMS ON HEADSTONES, LEAN AGAINST OR SIT ON
HEADSTONES.
4. THE EFFECT OF WORK ON PUBLIC ACCESS SHALL BE MINIMAL AND SHALL BE COORDINATED WITH THE
CEMETERY DIRECTOR. ANY ALTERED PUBLIC TRAFFIC ROUTES SHALL BE WELL DEFINED WITH
PROFESSIONALLY MADE SIGNAGE AND/OR OTHER APPROVED CONVENTIONAL METHODS.
5. DO NOT WORK UPON NOR STORE ANY MATERIALS ON OCCUPIED COLUMBARIUM WALLS. ALL EFFORT
WILL BE MADE TO MAINTAIN DISTANCE FROM OCCUPIED COLUMBARIUM WALLS.
CODE OF CONDUCT
1. TOPOGRAPHIC INFORMATION PROVIDED BY SURVEY PERFORMED BY ATC DESIGN GROUP DATED
DECEMBER 1, 2021. THE GENERAL CONTRACTOR SHALL VERIFY ALL SURVEY INFORMATION.
2. THE BASIS OF BEARINGS FOR THE SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, ZONE 5 CCS83 (2017.5 EPOCH) AS DETERMINED LOCALLY BY FIELD OBSERVED TIES TO CONTINUOUS OPERATING REFERENCE STATION (CORS) "BLSA" HAVING A CALIFORNIA COORDINATE VALUE OF 1ST ORDER
ACCURACY OR BETTER.
3. THE EXISTING UNDERGROUND UTILITIES SHOWN HEREON ARE BASED UPON AVAILABLE INFORMATION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL UTILITIES
PRIOR TO BEGINNING ANY WORK. IF UTILITIES OTHER THAN THOSE SHOWN HEREON ARE
ENCOUNTERED, THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY AND TAKE APPROPRIATE
MEASURES TO PROTECT THE LINE(S) AND ENSURE CONTINUED SERVICE. DAMAGE CAUSED TO
EXISTING UTILITIES BY THE CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL VERIFY THE CONNECTION POINTS OF
NEW UTILITIES TO EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION.
4. THE CONTRACTOR SHALL INSTALL TREE PROTECTION BARRICADES PRIOR TO BEGINNING EARTHWORK
OPERATIONS.
5. THE CONTRACTOR SHALL NOTIFY THE COR IF UNSUITABLE MATERIAL IS DISCOVERED PRIOR TO
BEGINNING ANY REMOVAL OPERATION. (SEE SPECIFICATION SECTION 31.20.00)
6. THE CONTRACTOR SHALL STABILIZE ALL DISTURBED AREA WITH SOD OR MULCH, NOT SHOWN FOR ASPHALT OR CONCRETE, WITHIN LIMITS OF DEMOLITION AND PROPOSED WORK. THIS INCLUDES
STAGING AREA AND LAYDOWN AREAS.
7. CONTRACTOR SHALL GRADE ALL DISTURBED AREAS TO DRAIN FOR POSITIVE FLOW PRIOR TO FINAL
APPROVAL.
8. THE DESIGN ADEQUACY AND SAFETY OF ALL BRACING, SHORING AND TEMPORARY SUPPORTS, ETC. IS
THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
9. IN PERFORMING CONSTRUCTION OBSERVATION VISITS TO THE JOB SITE, THE ENGINEER SHALL HAVE
NEITHER CONTROL OVER NOR RESPONSIBILITY FOR THE CONTRACTOR'S MEANS, METHODS,
SEQUENCE, TECHNIQUES OR PROCEDURES IN PERFORMING THE WORK.
10. THE CONTRACTOR'S MEANS, METHODS, SEQUENCE, TECHNIQUES OR PROCEDURES IN PERFORMING THE WORK IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR, WHO IS ALSO RESPONSIBLE FOR
COMPLYING WITH ALL HEALTH AND SAFETY PRECAUTIONS AS REQUIRED BY ANY REGULATORY
AGENCY.
11. THERE SHALL BE AT ALL TIMES, WHEN WORK IS BEING DONE, A COMPETENT PERSON WHO IS APPRISED OF THE CONDITION AND PROGRESS OF ALL AREAS OF WORK ON SITE. THIS COMPETENT PERSON SHALL BE ABLE TO SPEAK FOR AND ACT IN THE BEHALF OF THE CONTRACTOR. HE SHALL BE
AWARE AND KNOWLEDGEABLE OF ALL THE SAFETY CONCERNS ON THE JOB SITE. HE SHALL BE
EMPOWERED TO IMMEDIATELY AND EFFECTIVELY MITIGATE THE ACTIONS OF ANY WORKMAN ON SITE.
12. CONTRACTOR SHALL PREPARE AND SUBMIT A WELDING PLAN TO THE COR PRIOR TO PERFORMING
ANY FIELD WELDING SHOULD IT BE REQUIRED. FOLLOWING APPROVAL ALL WELDS SHALL BE
PERFORMED IN ACCORDANCE WITH THE APPROVED PLAN.
GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved: Project Director Juan Kays Department of Veteran Affairs, NCA
Phone: 202.873.6488 Email: juan.kays@va.gov
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
NA
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E: Vali Cooper International
STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
889CM3034
Building Number
Los Angeles, California
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
VCI
Project Management
Construction Management
Engineering
5/24/23 Sheet of 95
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
5/24/23
00404366C O
LO
RADO L ICENS
E
D
A
RC H I T ECT
S
EA
N
M. F ITZPATR
IC
K
C U s e rs \D a n ia H a b b o u b
\V a li C o o p e r
In te rn a ti o n a l\ V
A N
C A
L A
N C
G ra v e s it e E x p a n s io n
C o lu m b a ri u m
D o c u m e n ts
\a W o rk
F ile s
M a in te n a n c e
\7
B id
D o c s
R e v is io n s f o r S in g le
P ro je c t B id
.1
.2
\1
P la n s \C
A D
\L A
N C
C
M
M a in t_ A rc h it e c tu ra l.
rv t
/5 /2
:2
:1
P M
G-001
COVER SHEET
FITZ TM
Revisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
G-101
SITE ACCESS, FENCING AND
STAGING PLAN
0 0 0
ON SAFETY
ZERO
DeSDrWmenW oI VeWerDns AIIDirs
PAINTED BORDER
MEMBER BLACK ENAMEL
2" X 4" FRAME AND BRACES
IN SAME PLANE
METAL FACE
STRETCH METAL FACE
TIGHT, TURN OVER FRAME
AND SECURE WITH FLAT
HEAD DEFORMED NAILS
LETTERING TO BE
HELVETICA STYLE 5"
HIGH
METAL FACE WHITE
ENAMEL
LETTERING TO BE
HELVETICA STYLE 3"
HIGH TO BE CENTERED
HORIZONTALLY
2" X 4" FRAME AND
BRACE IN BACK
LETTERING TO BE
HELVETICA STYLE 2" HIGH
TO BE CENTERED
HORIZONTALLY
LETTERING TO BE
HELVETICA STYLE 1-1/2"
HIGH TO BE CENTERED
HORIZONTALLY
4" X 4" POSTS
PAINTED WHITE
BORDER MEMBER
PAINTED BLACK
BACKGROUND TO BE
PAINTED WHITE
LETTERING TO BE
HELVETICA STYLE 1"
HIGH TO BE CENTERED
HORIZONTALLY
LETTERING TO BE
HELVETICA STYLE 1-1/2"
HIGH TO BE CENTERED
HORIZONTALLY
SURROUNDING BORDER TO
BE BLUE
CENTER TO BE WHITE
8'-8"
6"
1-1/2" 3" 5" 2" 5" 5" 3" 2"
1-1/2"
4'-0" MIN.
3"
6"
9"
6"
3" 2" 3"
6"
ALL LETTERING TO BE
PAINTED BLACK WITH
EXCEPTION OF PROJECT
TITLE WHICH IS TO BE BLUE
NOTE:
ANY SEAM IN METAL TO BE
FLAT SEAM - SEAMS TO BE
HORIZONTAL AND OCCUR
BETWEEN LINES OF
LETTERING.
SECTION ON CENTER
4'-0"
BRACING
3'-0"
VARIES
3'-0"
BLUE
BLUE
OUTLINE
WITH WHITE
INTERIOR
BLUE
WHITE
RED
RED
2"
2"
2"
1-3/4"
2"
WOOD STRIPS
BRACING
4" X 4" POST IF SIGN IS
INSTALLED ON GRADE
FIN. GRADE
SCALE: NTS
SAFETY SIGND8
SCALE: NTS
PROJECT SIGNB6
VARIES;
AVERAGE 3'-0"
LEGEND AND SYMBOLS
CONSTRUCTION STAGING AREA
PROJECT & SAFETY SIGNAGE
CONSTRUCTION FENCE
ACCESS / HAUL ROUTE
PROJECT SIGN;
SEE DETAIL B6
THIS SHEET
SAFETY SIGN;
SEE DETAIL D8
THIS SHEETACCESS/HAUL
ROUTE
SEE
ENLARGEMENT
BELOW
ACCESS/HAUL ROUTE
EXISTING GROUNDS
CONTRACTOR YARD
TEMPORARY NCA
MAINTENANCE
AREA (130x270')
8' TALL CONSTRUCTION
PRIVACY FENCE PER
SPECIFICATIONS WITH
LOCKABLE 20' ACCESS GATE.
FENCING TO BE REMOVED AT
THE COMPLETION OF THE
PROJECT
APPROXIMATE LOCATION OF THE
EXISTING 1" DOMESTIC WATER LINE
24x60 OFFICE TRAILER
TEMPORARY MAINTENANCE YARD NOTES:
1. TEMPORARY MAINTENANCE YARD SHALL BE FULLY FUNCTIONAL PRIOR TO
CONSTRUCTION AT THE MAINTENANCE FACILITY.
2. CONTRACTOR SHALL RELOCATE THE EXISTING FURNITURE & TOOLS IN THE
MAINTENANCE COMPLEX TO THE TEMPORARY MAINTENANCE YARD.
2.1. CONTRACTOR SHALL MOVE THE TOOLS BACK TO THE COMPLETED
MAINTENANCE YARD AT THE COMPLETION OF THE PROJECT
2.2. CONTRACTOR SHALL DISPOSE OF THE EXISTING FURNITURE AT THE
COMPLETION OF THE PROJECT.
3. TEMPORARY MAINTENANCE YARD SHALL REMAIN UNTIL THE COMPLETE TURNOVER
OF THE MAINTENANCE FACILITY.
4. CONTRACTOR SHALL PROVIDE ONE 24' X 60' OFFICE TRAILER WITH TWO OFFICES
WITHIN THE TEMPORARY MAINTENANCE AREA AND ALL REQUIRED
APPURTENANCES.
4.1. OFFICE TRAILER HAVE A PRE-WIRED, DEDICATED ELECTRICAL PANEL.
4.1. TRAILER SHALL HAVE WINDOW AND DOOR SECURITY.
4.2. CONTRACTOR SHALL PROVIDE DATA TO THE TRAILER AT NO ADDITIONAL COST
TO THE GOVERNMENT.
4.2.1. EXISTING DATA IS LOCATED WITHIN THE IT ROOM AT THE RESTROOM/IT
BUILDING.
4.2.2. DATA FIBER SHALL BE ROUTED UNDERGROUND. ROUTING TO BE
APPROVED BY THE COR PRIOR TO INSTALLATION
4.2.3. FIBER SHALL BE 12SM FIBER OPTIC.
5. CONTRACTOR SHALL PROVIDE A WATER SPIGOT BETWEEN THE WORKSHOP
CONEXES.
6. CONTRACTOR SHALL PROVIDE TWO PORTACOOL JETSTREAM 250 (OR APPROVED
EQUAL) EVAPORATIVE COOLERS.
7. CONTRACTOR SHALL RELOCATE THE EXISTING HAZARDOUS MATERIALS STORAGE
LOCKER LOCATED AT THE EXISTING MAINTENANCE YARD. AT THE COMPLETION OF
THE PROJECT, THE CONTRACTOR SHALL MOVE THE LOCKER BACK TO THE
MAINTENANCE YARD.
8. CONTRACTOR SHALL PROVIDE ONE DOUBLE WALL DIESEL FUEL TANK WITH PUMP
AND DISPENSER WITH A HOLDING CAPACITY OF 500 GALLONS MINIMUM. THE
CONTRACTOR IS NOT RESPONSIBLE FOR PROVIDING FUEL.
9. CONTRACTOR SHALL PROVIDE ONE 40' CONEX (END OPENING) FOR STORAGE, NO
LIGHTING OR POWER IS REQUIRED.
10. CONTRACTOR SHALL PROVIDE TWO 40' CONEXES (SIDE OPENING ) WITH
PRE-WIRED LIGHTING AND POWER TO BE USED AS TEMPORARY WORKSHOPS.
10.4. EACH CONEX SHALL BE OUTFITTED WITH A MINIMUM OF (4) FOUR LED LIGHTS
TO MEET THE MINIMUM LIGHTING REQUIREMENT OF 40 FT/CANDLE.
10.5. EACH CONEX SHALL HAVE A MINIMUM OF (6) SIX PRE WIRED DUPLEX OUTLETS.
10.6. EACH CONEX SHALL HAVE A DEDICATED 125 AMP, 3 CIRCUIT BREAKER PANEL.
ALL GROUNDING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 70, AND ALL
GOVERNING CODES AND STANDARDS.
11. CONTRACTOR SHALL PROVIDE ONE THREE STATION RESTROOM/SHOWER COMBO
TRAILER.
11.1. COMBO TRAILER SHALL HAVE A MINIMUM OF ONE SHOWER.
11.1. COMBO TRAILER HAVE A PRE-WIRED, DEDICATED ELECTRICAL PANEL.
11.2. CONTRACTOR SHALL PROVIDE FIVE LOCKERS INSIDE OF THE SHOWER ROOM.
11.3. A MINIMUM OF ONE RESTROOM SHALL BE ABA ACCESSIBLE.
11.4. HOT WATER SHALL BE INCORPORATED.
11.5. CONTRACTOR SHALL PROVIDE SEWAGE HOLDING TANK (S), AND IS
RESPONSIBLE FOR SCHEDULED CLEANOUTS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
11.6. CONTRACTOR SHALL CONNECT TRAILER TO THE EXISTING DOMESTIC
WATERLINE AVAILABLE ON-SITE.
12. CONTRACTOR SHALL PROVIDE A MAIN ELECTRICAL PANEL FOR THE TEMPORARY
MAINTENANCE YARD AT A RATE OF 250 AMPS. ALL GROUNDING SHALL BE PROVIDED
IN ACCORDANCE WITH NFPA 70, AND ALL GOVERNING CODES AND STANDARDS.
12.1. POWER SHALL BE PROVIDED FROM THE EXISTING SWBD-505.
12.2. POWER SHALL BE ROUTED UNDERGROUND.
40' STORAGE CONEX
(2) 40' WORKSHOP CONEX
W/ POWER & LIGHTS
DIESEL STORAGE TANK
HAZARDOUS MATERIALS LOCKER
EXISTING STORAGE CONEX
THREE STATION RESTROOM TRAILER
WITH SHOWER. (TWO TOILETS AND
ONE TOILET SHOWER COMBO)
CONTRACTOR
STAGING AREA
EXISTING FENCING
SWBD-505 LOCATION
DATA ACCESS LOCATION
UNDERGROUND DATA FIBER
FIBER SHALL BE INSTALLED
ADJACENT TO THE EXISTING
CURB UNDER THE ASPHALT
PAVING.
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INE ER
05/24/2023
AMIENS AVENUE
SOISSONS AVENUE
370.360
IE
373.820
IE
378.900
TG B
379.020
TG
378.750
TG E
378.820
TG
379.580
TC B
379.420
INLET B
379.520
INLET E
X
X
X
X
X
X
X
X
CO
CO
387 388 389
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
LIMITS OF DISTURBANCE
LEGEND AND SYMBOLS
EROSION CONTROL NOTES:
1. TEMPORARY EROSION CONTROL DEVICES SHOWN ON
THE GRADING PLAN WHICH INTERFERE WITH THE
WORK SHALL BE RELOCATED OR MODIFIED WITH
APPROVAL FROM THE COR AS THE WORK
PROGRESSES TO MEET "AS GRADED" CONDITIONS.
2. ALL LOOSE SOIL AND DEBRIS SHALL BE REMOVED
FROM THE STREET AREAS UPON STARTING
OPERATIONS AND PERIODICALLY THEREAFTER AS
DIRECTED BY THE COR .
DUST CONTROL NOTES:
1. DUST SHALL BE CONTROLLED BY WATERING AND/OR
APPLYING A DUST PALLIATIVE.
2. WATER FOR DUST CONTROL SHALL BE APPLIED BY
MEANS OF PRESSURE TYPE DISTRIBUTORS OR PIPE
LINES EQUIPPED WITH A SPRAY SYSTEM OR HOSES
WITH NOZZLES THAT WILL ENSURE A UNIFORM
APPLICATION OF WATER.
3. UNLESS WATER IS APPLIED BY MEANS OF PIPE LINES,
AT LEAST ONE MOBILE UNIT WITH A MINIMUM
CAPACITY OF 100 GALLONS SHALL BE AVAILABLE FOR
APPLYING WATER.
4. ALL SOIL MATERIALS OR DEBRIS TRUCKED FROM THE
SITE SHALL BE COVERED AND MOISTENED PRIOR TO
ENTERING PUBLIC STREETS.
SILT FENCING
INLET PROTECTION
CONSTRUCTION ENTRANCE
CONCRETE WASHOUT AREA
KEYED NOTES
1. INLET PROTECTION, SEE DETAIL B2/ C-504
2. SILT FENCE OR FIBER ROLLS, SEE DETAIL D2/ C-504
3. CONSTRUCTION ENTRANCE, SEE DETAIL B9/C-504.
4. CONCRETE WASHOUT AREA, SEE DETAIL B5/C-504.
5. CONSTRUCTION FENCING WITH PRIVACY FABRIC.
CONSTRUCTION FENCING
0 10 20
1 INCH = 10 FEET
EROSION AND SEDIMENTATION
CONTROL PLAN
GC101
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INEER
TM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENT
SUBMITTAL
N/A
National Cemetery Administration
Design and Construction Service
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
LOS ANGELES NATIONAL CEMETERY
CONSTRUCT MAINTENANCE FACILITY
Los Angeles, CA
898CM3034
N/A Project Director
5/24/2023Revisions: Date: Sheet of 95
VCI Project Management Construction Management Engineering Juan Kays
Department of Veterans Affairs, NCA
Phone: 202.632.5057 Email: juan.kays@va.gov
1331 17TH STREET SUITE 605
DENVER, COLORADO 80202
PHONE: (720) 439-4700
WEBSITE: www.dci-engineers.com
CIVIL / STRUCTURAL
JD Engineering, PC 371 Zimmerman Lane Hamilton, MT 59840 Phone: (406) 218 - 9980
720.491.7559; Sean Fitzpatrick
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433 SF JV
0 10 20
1 INCH = 10 FEET
VICINITY MAP
SITE
BASIS OF BEARINGS BENCHMARK
TOPOGRAPHIC SURVEY
V-101
No. 44593
PROFESSIONAL
REGISTERED
JORDAN D. VANDERMEE
RENG INEER
File details come from the government source that posted it. Updated .