About this file

This document establishes the General PUD Performance Standards for public utilities infrastructure operated by Collier County's Public Utilities Department in Florida. The standards apply to water plants, wastewater plants, master pump stations, community pump stations, solid waste sanitary landfills, transfer stations, and related facilities. The 5N-Reliability Engineering Criteria establish mandatory performance benchmarks that must be incorporated into all solicitations, agreements, and contracts for these utilities. These criteria require zero offsite odors, zero sanitary sewer overflows or spills both offsite and onsite, zero offsite fugitive dust emissions, noise mitigation to acceptable levels prior to facility fence lines per applicable code, and light emission mitigation to acceptable levels prior to fence lines per code. All performance standards must be maintained 24/7/365. Any deviations from these established criteria require advance review and written recommendation from both the Engineering and Operations Division Directors and must be approved by the Department Head before implementation.

The related Biosolids Hauling Services contract opportunity issued by Collier County Board of County Commissioners Procurement Services Division represents a grant-funded initiative to procure hauling services for biosolids through a competitive Request for Proposals process. Prospective proposers must meet all specifications and scope of work requirements outlined in the solicitation. Historical annual expenditures for biosolids hauling have approximated $3,700,000, though this figure may not reflect future purchasing patterns. The contract will be subject to the aforementioned PUD Performance Standards, meaning the selected contractor must comply with all 5N-Reliability Engineering Criteria regarding odors, spills, dust emissions, noise, and light emissions during the execution of biosolids hauling operations.

View the file

Other files

File Type Posted
PB_RenewPrice_Increase_PO_exp._5.30.2027.pdf PDF
PB_Renewal.pdf PDF
PB_Synagro_Addendum_FE.pdf PDF
25-8403R_Solicitation_.pdf PDF
Checklist_-Vendor_Checklist.pdf PDF
Fixed_Term_Service_Multi-Contractor_Award_Agreement_[2026__ver.1].pdf PDF
25-8403R_Authorization_to_Advertise.pdf PDF
Checklist_-Vendor_Checklist.pdf PDF
Fixed_Term_Service_Multi-Contractor_Award_Agreement_[2026__ver.1].pdf PDF
Checklist_-Vendor_Checklist.pdf PDF
Fixed_Term_Service_Multi-Contractor_Award_Agreement_[2026__ver.1].pdf PDF
25-8403R_Exhibit_C_-_GENERAL_PUD_PERFORMANCE_STANDARDS.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
25-8403R_Authorization_to_Advertise.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
25-8403R_Insurance_Requirements.pdf PDF
Form_3_Immigration_Certification.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Exhibit_B-1_-_NCWRF_SCWRF_Analysis.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
25-8403R_Solicitation_.pdf PDF
Form_3_Immigration_Certification.pdf PDF
Form_5_Grant_Provisions.pdf PDF
25-8403R_Exhibit_B-1_-_NCWRF_SCWRF_Analysis.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
Form_5_Grant_Provisions.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Attachment_A_-_Category_Interest.pdf PDF
25-8403R_Exhibit_A_-_Plant_Details_Production_Rates.pdf PDF
25-8403R_Exhibit_B-1_-_NCWRF_SCWRF_Analysis.pdf PDF
25-8403R_Exhibit_B-2_-_Golden_Gate_Orange_Tree_Analysis.pdf PDF
25-8403R_FPP_FEMA_97.036_12.25.pdf PDF
Fixed_Term_Service_Multi-Contractor_Award_Agreement_[2026__ver.1].pdf PDF
Form_2_Conflict_of_Interest_Certification.pdf PDF
Form_5_Grant_Provisions.pdf PDF
25-8403R_Attachment_B_-Cost_of_Services_02-18-26.xlsx XLSX spreadsheet
25-8403R_FPP_FEMA_97.036_12.25.pdf PDF
Form_2_Conflict_of_Interest_Certification.pdf PDF
Form_4_Reference_Questionnaire.pdf PDF
25-8403R_Attachment_A_-_Category_Interest.pdf PDF
25-8403R_Attachment_B_-Cost_of_Services_02-18-26.xlsx XLSX spreadsheet
25-8403R_Insurance_Requirements.pdf PDF
Form_1_Vendor_Declaration_Statement.pdf PDF
Form_2_Conflict_of_Interest_Certification.pdf PDF
Form_4_Reference_Questionnaire.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
Request_for_Proposals_Instructions_Version_2.pdf PDF
25-8403R_Exhibit_C_-_GENERAL_PUD_PERFORMANCE_STANDARDS.pdf PDF
25-8403R_Insurance_Requirements.pdf PDF
Form_3_Immigration_Certification.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The following 5Ns are the PUD Performance Criteria that needs to be considered and included in

• solicitations,

• agreements,

• contracts, that are specifically related to our Water Plants, Wastewater Plants, Master Pump Stations, Community Pump Stations R&Rs, Solid Waste Sanitary Landfills, Transfer Stations, among others

PUBLIC UTILITIES

5N-RELIABILITY ENGINEERING CRITERIA

No offsite odors | 24/7/365

No SSOs-Spills offsite/onsite | 24/7/365

No offsite fugitive-dust emissions | 24/7/365

No offsite Noise | To be mitigated prior to fence line per Code | 24/7/365

No offsite Light emissions | To be mitigated prior to fence line per Code

Any deviation to above 5N-Reliability Engineering Criteria and guidance has to be reviewed and recommended by both Engineering and Operations Division Directors in advance for approval by the Department Head.