25-0530_COSM_455_County_Center,_RWC_Hazmat_Survey_Report_052625_Revision.pdf

PDF 2 MB Posted

Attached to
County Office Building 1 Renovation and Modernization Work Package 2 (WP2) Project (Project No. P33Z1)
Solicitation number
2027-RFP-00118
Issued by
San Mateo County, California

About this file

This is a Limited Pre-Renovation Hazardous Materials Survey Report prepared by Vista Environmental Consulting for the County of San Mateo regarding 455 County Center in Redwood City, California. The survey was conducted on September 19, 2024, and October 2, 2024, to identify hazardous building materials in advance of the County Office Building 1 Renovation and Modernization Work Package 2 Project. The survey examined the First Floor and Partial Basement of the Hall of Justice building and identified multiple categories of hazardous materials requiring proper handling and disposal prior to construction activities. The project involves renovation work with a contract time of 204 calendar days from the Notice to Proceed, with Level 1 Work completion required within 152 calendar days by May 9, 2027.

The survey identified asbestos-containing materials including spray-applied acoustical ceiling (3,300 SF, Class I Friable), vinyl floor tile and mastic (16,000 SF, Class II Non-Friable), fireproofing on structural elements (36,750 SF, Class I Friable), and pipe insulation (100 EA, Class I Friable). Lead-based paint and lead-containing materials were detected on select surfaces, with one positive XRF reading of 12.8 mg/cm² on a ceramic lower wall component and another positive reading of 1 mg/cm² on a metal pipe. Additional hazardous materials including universal waste items, suspect PCB-containing light fixture ballasts, and devices with ozone-depleting chemicals were visually identified. All asbestos abatement must comply with California Code of Regulations, Title 8, Section 1529, BAAQMD Regulation 11, and require Cal/OSHA registered contractors and California-certified asbestos consultants. Lead disturbance activities must comply with Cal/OSHA Title 8 CCR 1532.1, Cal/EPA waste disposal requirements, and CDPH regulations. The report emphasizes that all quantity estimates are order-of-magnitude only and contractors are responsible for verifying actual quantities and locations through site visits and contractual documents prior to bidding.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Limited Pre-Renovation Hazardous Materials Survey Report County of San Mateo

455 County Center, Redwood City, CA

Prepared for:

555 County Center Redwood City, CA 94063

Prepared By:

Vista Environmental Consulting

2984 Teagarden Street San Leandro, CA 94577

October 29, 2024

Project No. 241101006 chris Revised chris Typewriter May 26, 2025 i

TABLE OF CONTENTS

EXECUTIVE SUMMARY

PAGE

1. INTRODUCTION 1

2. METHODOLOGY 2

3. RESULTS 4

4. RECOMMENDATIONS 5

5. LIMITATIONS & EXCLUSIONS 8

APPENDICES

A. BUILDING DATA

Hazardous Materials Summary

Asbestos Sampling Inventory

Sample Location Drawings

Asbestos Analytical Reports

Lead XRF Sequential Reports i

EXECUTIVE SUMMARY

Vista Environmental Consulting (Vista) performed a limited pre-renovation hazardous materials survey at

455 County Center, Redwood City, CA 94063 (Project Site). The survey was performed to identify and sample accessible, suspect asbestos-containing materials, representative building components for the presence of lead-containing surface coatings/lead-based paints (LCSC/LBP), Polychlorinated Biphenyls

(PCBs) in light fixture ballasts, and other hazardous materials that may be in the path the construction.

Vista performed the survey on September 19, 2024 and October 2, 2024.

The following building was surveyed and contain the following hazardous materials:

Building/Areas Asbestos Lead-Based Paint or

Materials Lead Containing

Paint

Universal Waste, Suspect PCBs, and Other Hazardous

Materials

First Floor and Partial Basement

The Hazardous Materials Summaries, Asbestos Sampling Inventories, Sample Location Drawings, Asbestos Analytical Reports, and Lead XRF Sequential Reports can be found in Appendix A – Building

Data.

The documents found in the appendices are not stand-alone documents and should not be separated from this report. Quantities and locations listed in the tables are order of magnitude estimates and are not to be used for bidding purposes. It is the sole responsibility of the contractor to verify quantities and locations of hazardous materials in the path of construction through site visits and contractual bid set documents, including, but not limited to all specifications, drawings, and addenda. Any discrepancies between the contractual bid set documentation and site visits must be submitted in writing to the Owner or Owner’s representative, prior to bidding.

BAAQMD classifications are based upon the material’s condition at the time of the survey or as rendered as a result of standard manual removal/demolition techniques. The use of “mechanical means”, non-standard or other aggressive removal/demolition techniques may result in a different classification.

All Class I and II asbestos (>0.1%) disturbance and/or removal operations must be conducted by a

Cal/OSHA registered and State licensed asbestos removal contractor. All disturbance and/or abatement operations should be under the direction of a California Certified Asbestos Consultant.

Should the removal of identified regulated asbestos-containing materials (RACM) involve at least 100 square feet or 100 linear feet per project site, per year, then notification to the Bay Area Air Quality

Management District (BAAQMD) and Cal/OSHA must be accomplished prior to the initiation of such activities.

ii

All activities involving potential and identified lead-containing surfaces should be conducted in accordance with California Health & Safety Code sections 17920.10 and 10525, 10525.7, Title 8, California Code of Regulations (CCR), Section 1532.1.

In addition, all removal activities involving identified lead-based paints (LBP) must be conducted in accordance with Title 17, CCR, Division 1, Chapter 8, Sections 35001 through 36100, which proscribes the use of California Department of Public Health (CDPH) certified workers, work practices, and other requirements.

Written notification to Cal/OSHA must be accomplished should LBP activities involve equal to or more than 100 square feet or 100 linear feet of removal in accordance with the requirements of 8 CCR 1532.1.

Any welding, cutting or heating of metal surfaces containing surface coatings should be conducted in accordance with 8 CCR 1537 Welding, Cutting, and Heating of Coated Metals, which require surfaces covered with toxic preservatives, and in enclosed areas, be stripped of all toxic coatings for a distance of at least 4 inches, in all directions, from the area of heat application prior to the initiation of such heat application, or 8 CCR 1536 Ventilation Requirements for Welding, Brazing, and Cutting.

All potential and identified Universal Waste materials (UW) and Electronic Waste (E-Waste) impacted by the work should be removed and recycled or disposed of in accordance with the UW guidelines established by the DTSC, as stated in 22 CCR Sections 66261.9 and 66273.1 thru 66273.90.

All ballasts must be visually inspected prior to disposal to determine if they contain PCB’s. Those ballasts marked No PCB’s or PCB Free can be considered as such as should be treated as UW - electronic waste.

All PCB-containing devices, including, but not limited to ballasts should be removed or have the oils removed and properly handled, collected, stored, transported and recycled or disposed of by an approved recycling or disposal facility in accordance with the requirements of Title 22 CCR 67426.1.

Devices containing ozone depleting chemicals and low-level radiation should be collected, waste characterized, disposed or recycled according to California rules and regulations.

Should materials similar to those identified in this report, or if other forms of suspect hazardous materials are encountered, contractors should be instructed to immediately cease work activities which may initiate an exposure episode, and notify the appropriate management personnel.

iii

Report prepared for the Company by:

Christopher R. Burns Senior Project Manager

CAC #92-0224

LRCIA #LRC-00006938

455 County Center, Redwood City October 29, 2024 Hazardous Materials Survey Report Project No. 241101006

1.0 INTRODUCTION

Vista Environmental Consulting, Inc. (Vista) has prepared this limited pre-renovation hazardous materials survey report for 455 County Center, Redwood City, CA 94063 (Project Site) for the County of San

Mateo (COSM).

The survey of the Project Site was generally consistent with the Vista proposal dated August 26, 2024 and approved by COSM.

The following areas of the Hall of Justice building was surveyed:

First Floor

Partial Basement for drilling of holes through concrete ceiling.

The purpose of this survey was to identify hazardous building materials so they can be removed; waste characterized, and properly disposed of prior to being impacted by renovation activities. The data provided in this report can assist all parties involved in this project make informed decisions with regards to regulatory compliance and the health and safety of their employees. This survey included the following:

Visible and accessible suspect asbestos-containing materials (ACM) were assessed and sampled to determine asbestos content.

Representative painted and coated building components were assessed and categorized based upon standard selective demolition practices and sampled for lead content which can be used in preliminary waste stream characterization estimates.

Visible and accessible materials with the potential to have hazardous properties that are regulated and are commonly found in buildings were assessed, but not sampled. These materials include, but are not limited to:

Universal Waste (UW) materials, such as non-incandescent lamps, batteries, mercury-containing devices, and electronic waste; Batteries include, but are not limited to those found in exit signs, emergency lights, fire alarm systems, and back-up power systems;

Polychlorinated biphenyls (PCBs) containing devices such as lamp ballasts, wet-type transformers, and hydraulic systems;

Devices which may contain ozone depleting chemicals, such as Heating, Ventilation and

Air Conditioning (HVAC) systems, refrigerators, freezers, fire suppression systems and water coolers/fountains;

Devices with low-level radioactive sources such as smoke detectors and exit signs.

2.0 METHODOLOGY

Vista performed the pre-demolition hazardous materials survey on September 16, 2024 and October 2, 2024.

Vista’s personnel on the project were:

Christopher Burns, a State of California Division of Occupational Safety and Health (Cal/OSHA)

Certified Asbestos Consultant (CAC) # 92-0224 and a State of California Department of Public

Health (CDPH) Lead Related Construction Certified Inspector/Assessor (LRCIA) #LRC-

00006938

Javier Rocha, a Cal/OSHA Certified Site Surveillance Technician (CSST) #02-3244 and a CDPH

Lead Related Construction Certified Sampling Technician (LRCST) #LRC-00000629

Alana Anderson, a CAL/OSHA CSST #24-7640 and CDPH LRCST #LRC-00009273

Vista’s intent was to perform a thorough survey and made a good faith effort to access all building materials down to the structural components and/or interstitial spaces. Quantities and locations are based upon areas that were accessed. Materials similar to those in this report may be present in areas which were not accessed.

2.1 Asbestos

The asbestos survey was performed generally in accordance with the AHERA protocol (40 CFR Part 763, Subpart E). Visual identification was performed by assessing visible and accessible structural, architectural, and mechanical components for the presence of suspect ACM at the Project Site.

This limited ACM survey was conducted in the following manner:

➢ Suspect ACM was categorized into homogeneous materials. A homogeneous material is defined as being a surfacing material, thermal system insulation, or miscellaneous material which is uniform in color and texture. It may also be additionally subcategorized using the date of installation, when available.

➢ A sampling scheme was developed based upon the location and quantity of the suspect homogeneous ACM. A rough order of magnitude estimate of each suspect homogenous ACM was calculated and recorded for future reference. A sampling scheme, including a specific number of samples per suspect homogeneous ACM, was calculated prior to sampling.

➢ Sampling guidelines established by the United States Environmental Protection Agency (USEPA) were utilized for sampling each suspected homogeneous ACM. Methods described in Appendix

K of 8 California Code of Regulation (CCR) 1529 were utilized in the collection of each suspect homogeneous ACM sample.

➢ Trained California asbestos certified personnel, using appropriate sampling tools and sterile leak-tight Whirl-pak® containers, collected building materials that were suspected to contain ACM.

➢ Each suspect ACM sample was collected and sealed in its container and appropriately labeled with a unique sample identification number and recorded on an asbestos bulk sampling log. Each log contains a chain-of-custody to assure the proper transition of the samples from Vista to the analytical laboratory.

➢ Sampling tools were decontaminated, by using a clean wet cloth, between collection of each suspect sample to prevent the possibility of cross contamination of subsequent suspect ACM samples.

Suspect ACM samples were delivered, under proper chain-of-custody protocol, to SGS Laboratories

(SGS) in Hayward, California. SGS is accredited under the National Voluntary Laboratory Accreditation

Program (NVLAP) and the California Environmental Laboratory Accreditation Program (Cal-ELAP).

The samples were submitted for analysis by Polarized Light Microscopy (PLM) utilizing dispersion staining techniques in accordance with the EPA’s “Method for the Determination of Asbestos in Bulk

Building Materials” U.S. EPA/600/R-93/116, Visual Area Estimate, dated July 1993 and adopted by the

NVLAP as Test Method Code 18/A01.

One sample of “trace” joint compound was further analyzed by U.S. EPA/600/R-93/116, Point Count

Analysis (1,000 points).

2.2 Lead

Vista’s lead construction screening survey used an X-Ray Fluorescence (XRF) direct read spectrum analyzer device to take readings of representative painted and coated surfaces for evaluation of lead levels for worker health and safety and preliminary waste characterization prior to construction activities. The device used was a Viken Detection, XRF Lead Paint Analyzer, Model Pb200i. This device is a thermoelectrically-cooled, sealed, CdTe diode detector optimized X-ray detection and uses a sealed cobalt

57, 5mCi (185 MBq) isotope for an excitation source.

This survey was a limited screening of paint for the purpose of characterizing the lead content in paint and coatings likely to be disturbed during work activities. For this purpose, XRF analysis was used to screen for lead levels and provides results that are generally representative of typical conditions but are not inclusive of all painted/coated surfaces present at the Project Site. This survey was not a surface by surface inspection as outlined in the U.S. Department of Housing and Urban Development (HUD)

Guidelines For the Evaluation and Control of Lead-Based Paint Hazards in Housing pursuant to Title X of the Housing and Community Development Act of 1992. These analytical data can be helpful in evaluation of lead-related environmental risks in general, but cannot be used to calculate worker exposures and is not a substitute for employee exposure monitoring or waste stream sampling.

Lead-Based Paint (LBP) is defined by CDPH as any paint containing lead levels exceeding 0.5 wt % (or

5000 parts per million) via paint chip sampling or 1.0 milligrams per centimeter squared (mg/cm²) or greater via X-Ray Fluorescence (XRF) direct read instrument sampling. Cal/OSHA rules apply to “any detectable concentration of lead” without a specified detection level.

2.3 Other Hazardous Materials

Devices with potential hazardous materials were visually identified during the survey walk-through and their quantities were estimated and recorded. No attempt was made to disassemble devices or sample suspect materials within the devices. For example, fluorescent light fixtures must be presumed to contain

Universal Waste lamps, and ballasts which contain PCB oil are electronic waste, pending removal and disassembly of each unit to determine explicit product specific information that proves otherwise.

3.0 RESULTS

The following areas of the Hall of Justice building was surveyed and contain the following hazardous materials:

Building/Areas Asbestos Lead-Based Paint or

Materials Lead Containing

Paint

Universal Waste, Suspect PCBs, and Other Hazardous

Materials

First Floor and Partial Basement

The Hazardous Materials Summaries, Asbestos Sampling Inventories, Sample Location Drawings, Asbestos Analytical Reports, and Lead XRF Sequential Reports can be found in Appendix A – Building

Data.

The documents found in the appendices are not stand-alone documents and should not be separated from this report. Quantities and locations listed in the tables are order of magnitude estimates and are not to be used for bidding purposes. It is the sole responsibility of the contractor to verify quantities and locations of hazardous materials in the path of construction through site visits and contractual bid set documents, including, but not limited to all specifications, drawings, and addenda. Any discrepancies between the contractual bid set documentation and site visits must be submitted in writing to the Owner or Owner’s representative, prior to bidding.

BAAQMD classifications are based upon the material’s condition at the time of the survey or as rendered as a result of standard manual removal/demolition techniques. The use of “mechanical means”, non-standard or other aggressive removal/demolition techniques may result in a different classification.

4.0 RECOMMENDATIONS

4.1 Asbestos

The results of the survey indicate that asbestos-containing materials are present at the Project Site.

Work performed during any activities that disturb the asbestos-containing materials identified in this report must be done in compliance with the most recent edition of all applicable federal, state, and local regulations, standards, and codes governing abatement, transport, and disposal of asbestos-containing materials. These include, but are not limited to, the following:

CCR, Title 8, Chapter 3.2, Subchapter 2, Article 2.5 - Registration Asbestos-Related Work

Sections 341.6 through 341.14

CCR, Title 8, Section 1529 - Asbestos in the Construction Industry

BAAQMD Regulation 11, Hazardous Pollutants, Rule 2, Asbestos Demolition, Renovation and

Manufacturing

40 CFR Part 763 - Subpart E, Asbestos Containing Materials in Schools (AHERA)

California Code of Regulations, Title 17, Section 93015

CCR, Title 17, Section 93015 Asbestos Airborne Toxic Control Measure (ATCM) for

Construction, Grading, Quarrying and Surface Mining Operations

Materials encountered in the buildings that are not part of this report must be properly sampled for the content of asbestos or assumed to be asbestos containing prior to any disturbance.

Prior to Class I and II activities which will disturb identified or assumed asbestos, a Cal/OSHA registered and California licensed asbestos contractor must be utilized for abatement of asbestos that will be impacted. Vista recommends that all abatement operations be conducted under the direction of a

California Certified Asbestos Consultant.

4.2 Lead

The results of the survey indicate that lead-based materials and lead-containing paints/materials are present in the path of construction at the Project Site.

At present there is no state or federal regulation requiring mandatory lead removal or abatement prior to disturbance of building materials with identified lead paint or coatings. However, there are applicable

Cal/OSHA worker protection and training requirements, Cal/EPA waste disposal requirements, CDPH requirements for public and residential buildings, and SB 460 lead hazard regulations that apply to lead-related construction activities, abatement activities and their associated wastes. The following is a brief discussion and summary of applicable regulatory requirements:

♦ Cal/OSHA: Title 8, California Code of Regulation (CCR), Section 1532.1 (8 CCR 1532.1) governs occupational exposure to lead. This regulation requires that prior to initiation of certain activities, referred to as “trigger tasks”, workers must be trained, medically evaluated, and properly fitted with respiratory protection, and protective clothing until statistically reliable personal eight-hour time weighted average

(TWA) results indicate lead exposure levels below the Personal Exposure Limit (PEL) for each unique task which disturbs lead-based and lead-containing coatings. This process is known as a Negative

Exposure Assessment or NEA.

If the result of the exposure assessment is above the Action Level (AL) additional monitoring is required and if the result is above the PEL additional exposure monitoring, worker protection (including respirator protection and PPE), training and medical requirements apply. However even where the NEA criteria is met, certain hazard communication training and work practice controls still apply where lead is disturbed.

“Trigger tasks” are tasks that are assumed to exceed the PEL pending an exposure assessment and they encompass the majority of construction activities that disturb surface coatings. Examples of “trigger” tasks range from manual paint scraping as a lower expected exposure up to hot work and abrasive blasting as the highest expected exposures, and include any non-listed task that the employer determines may potentially expose employees to lead levels above the AL.

“OSHA does not consider any method that relies solely on the analysis of bulk materials or surface content of lead (or other toxic material) to be acceptable for safely predicting employee exposure to airborne contaminates. Without air monitoring results or without the benefit of historical or objective data (including air sampling which clearly demonstrates that the employee can not be exposed above the action level during any process, operation, or activity) the analysis of bulk or surface samples can not be used to determine employee exposure.”- OSHA Standard Interpretation May 8, 2000.

OSHA states that these rules apply to “any detectable concentration of lead” without a specified detection level. Due to the Consumer Product Safety Commission currently allowing paint to contain up to 90 parts per million (ppm) or 0.009 wt% of lead, the variation of lead content due to aging and weathering, and the variation of detection limits associated with analysis of bulk materials, such as paint chips and surface content analysis via XRF, it is recommended that all painted or coated surfaces be treated as potentially containing lead. Positive analytical results by either method can be used to indicate that detectable lead is present but negative results cannot be interpreted as conclusively demonstrating the absence of lead.

Analytical data from analysis of bulk materials or surface content of lead can be helpful in evaluation of lead-related environmental risks in general but cannot be used to calculate worker exposures and are not a substitute for employee exposure monitoring. As a result of the above, any employee that works around potential lead-based or lead-containing coatings must have HAZCOM training and personal exposure air monitoring is additionally required for employees that disturb such coatings. Significant additional certification, notification, and work practices are required for materials found to be lead-based.

Any welding, cutting or heating of metal surfaces containing surface coatings should be conducted in accordance with 29 CFR 1926.354 and 8 CCR 1537. These regulations require surfaces covered with toxic preservatives, and in enclosed areas, be stripped of all toxic coatings for a distance of at least 4 inches, in all directions, from the area of heat application prior to the initiation of such heat application.

♦ Cal/EPA through the Division of Toxic Substance Control (DTSC) regulates disposal of lead hazardous waste (22 CCR Division 4.5, Minimum Standards for Management of Hazardous and Extremely

Hazardous Wastes). DTSC has issued guidance indicating that architectural debris with intact lead paint is normally expected to be handled as general construction waste. However, waste stream segregation and analysis is still required for all lead painted or coated debris regardless if the paint or coating is intact on a building component or not. The resulting wastes may be hazardous under California and federal RCRA standards for lead and therefore require proper handling, packaging, labeling, and transportation under a proper manifest to a permitted hazardous waste storage, treatment and disposal facility.

♦ CDPH: The Department of Public Health (CDPH) has specific requirements (Title 17 Sections 35001 thru 36100 et. al.) for hazard assessment and work in public or residential structures in regards to lead-based paint. These regulations require special certifications, work practices, and notification for such activities.

♦ Senate Bill 460 (SB 460): An act to amend Section 1941.1 of the Civil Code, and to amend Sections

17961, 17980, and 124130 of, and to add Sections 17920.10, 105251, 105252, 105253, 105254, 105255, 105256, and 105257 to, the Health and Safety Code, relating to lead abatement. This bill allows for fines and criminal penalties to be levied on any person who is found to have performed lead abatement without containment or created a measurable “lead hazard” based upon current CDPH standards. A “lead hazard” means deteriorated lead-based paint, lead contaminated dust, lead contaminated soil, disturbing lead-based paint or presumed lead-based paint without containment, or any other nuisance which may result in persistent and quantifiable lead exposure.

Vista recommends that all parties that come into contact with paint that has detectable lead content follow all applicable federal, state and local regulations relating to employee health and safety and proper disposal of generated wastes.

4.3 Other Hazardous Materials

Other hazardous materials are present in the path of construction at the Project Site.

All potential and identified Universal Waste materials (UW) and Electronic Waste (E-Waste) impacted by the work should be removed and recycled or disposed of in accordance with the UW guidelines established by the DTSC, as stated in 22 CCR Sections 66261.9 and 66273.1 thru 66273.90.

Vista’s limited visual survey indicated that light fixtures with ballasts that may contain PCB oil are present. However, due to the limited nature of the random spot checks, Vista recommends that all ballasts be visually inspected prior to disposal to determine if they contain PCB’s. Those ballasts marked No

PCB’s or PCB Free can be considered as such as should be treated as UW - electronic waste.

Devices containing ozone depleting chemicals and low-level radiation should be collected, waste characterized, disposed or recycled according to California rules and regulations.

All personnel who perform hazardous materials work must be trained and qualified to do so. They must also follow the most current OSHA regulations including 29 CFR 1910.120 and 8 CCR 5192, Hazardous

Waste Operations and Emergency Response, as well as other applicable federal, state and local laws and regulations.

5.0 LIMITATIONS & EXCLUSIONS

Quantities and locations are based upon areas that were accessed. Materials similar to those in this report may be present in areas which were not accessed. Because of this, Vista recommends including line item pricing, allowances, and/or additive/deductive wording to bid sheets for unforeseen conditions.

All material quantities reported herein are rough order of magnitude estimates and should not be used for bidding purposes. All contractors are responsible for accurately determining quantities and locations of materials identified in this report.

The survey performed was limited to representative rooms/areas and did not include access of areas and sampling of materials which would have required large scale destructive testing. Vista made a good faith effort based on accepted industry standards to access all areas in order to assess their potential for having hazardous materials, however additional layers of roofing may be under the first layer of hard substrate.

Respectfully Submitted, Vista Environmental Consulting

Christopher R. Burns Senior Project Manager

CAC #92-0224

LRCIA #LRC-00006938

APPENDIX A - BUILDING DATA

COUNTY OF SAN MATEO

455 COUNTY CENTER, REDWOOD CITY

The information contained in these appendices are not stand alone documents and should not be separated from this report.

For specific regulatory requirements regarding these materials please refer to the information provided in the Main Report.

Quantities and locations listed in the tables are order of magnitude estimates and are not to be used for bidding purposes. It is the sole responsibility of the contractor to verify quantities and locations of hazardous materials in the path of construction through site visits and contractual bid set documents, including, but not limited to all specifications, drawings, and addenda.

Any discrepancies between the contractual bid set documentation and site visits must be submitted in writing to the Owner or Owner’s representative, prior to bidding.

BAAQMD classifications are based upon the material’s condition at the time of the survey or as rendered as a result of standard manual removal/demolition techniques. The use of “mechanical means”, non-standard or other aggressive removal/demolition techniques may result in a different classification. BAAQMD & Cal-OSHA classifications are based on the materials being >1% asbestos pending further analytical data that proves otherwise.

Rectangle

HAZARDOUS MATERIALS SUMMARY

Asbestos

HOMO.

ID

MATERIAL DESCRIPTION LOCATION

CAL/OSHA

CLASS

BAAQMD

CATEGORY

ESTIMATED

QUANTITY

A Spray Applied

Acoustical Ceiling

White, Ceiling Lobby and

Conference Room Class I

Friable (RACM when

Removed)

3,300 SF

C, V, PP

Vinyl Floor Tile/Mastic

9" Light Brown/Black

Throughout except Restrooms, Fan

Room, Lobby and Northeast

Computer Floor Areas. This material is under carpeting, computer flooring, wood ramps, other floor tiles and is assumed under walls.

Class II Category I - Non-Friable

16,000 SF

L Mastic Black, Mirror Restrooms Class II Category I - Non-Friable

100 SF

N Fireproofing White, Columns, Beams, Walls &

Ceiling

Throughout on Columns and beams and overspray on adjacent concrete decking. This material is over sprayed on plenum MEP fixture and debris is on ceiling panels and assumed inside wall cavities. Fan Room - Walls and

Ceilings.

Class I Friable

(RACM when Removed)

36,750 SF

AA Insulation 3" OD, White, Fittings

Restrooms and Janitor's Closets

Inside Wall Cavities and in

Ceiling Plenum.

This material was also identified in the basement, but is not in the anticipated scope of work.

Class I Friable

(RACM when Removed)

50 EA

HOMO.

ID

MATERIAL DESCRIPTION LOCATION

CAL/OSHA

CLASS

BAAQMD

CATEGORY

ESTIMATED

QUANTITY

BB Insulation 6" OD, White, Fittings

Fan Room and West of Fan Room in Ceiling Plenum.

This material was also identified in the basement, but is not in the anticipated scope of work.

Class I Friable

(RACM when Removed)

50 EA

TT

Wallboard/Joint

Compound

White/White, "Patina"

Unfinished

Throughout Ceiling plenum

Sporadically. This material is assumed to be contaminated with Fireproofing (N)

Unclassified (Joint

Compound Layer

<0.1% by Point Count)

NA (Joint Compound

Layer <0.1% by Point Count)

5,000 SF

ZZ Cement Panel Gray, Behind Metal, Under

Windows

Exterior Southwest Office Areas

Class II Category II - Non-Friable

200 SF

Lead

ROOM COMPONENT SUBSTRATE COLOR CONDITION PB UNITS

Interior Lower Wall Drywall White Intact 0.1 mg/cm2

Interior Door Frame Metal White Intact 0.3 mg/cm2

Interior Door Frame Metal White Intact 0.5 mg/cm2

Interior Door Metal White Intact 0.2 mg/cm2

Interior Door Metal White Intact 0.4 mg/cm2

Interior Lower Wall Concrete Gray Intact 0.1 mg/cm2

Interior Lower Wall Concrete Gray Intact 0.1 mg/cm2

Interior Door Frame Wood Varnish Intact 0.2 mg/cm2

Interior Door Frame Wood Varnish Intact 0.1 mg/cm2

Interior Floor Tile Black Intact 0.2 mg/cm2

Interior Floor Ceramic Multi-

Colored Intact 0.1 mg/cm2

Interior Floor Vinyl Beige Intact 0.1 mg/cm2

Interior Lower Wall Ceramic Yellow Intact 12.8 mg/cm2

Interior Ceiling Drywall White Intact 0.2 mg/cm2

Interior Ceiling Plaster White Intact 0.4 mg/cm2

Interior Door Wood Purple Intact 0.1 mg/cm2

Interior Door Metal Blue Intact 0.1 mg/cm2

Interior Lower Wall Plaster White Intact 0.1 mg/cm2

Interior Lower Wall Drywall Blue Intact 0.1 mg/cm2

Interior Lower Wall Drywall Blue Intact 0.1 mg/cm2

Interior Lower Wall Drywall Yellow Intact 0.1 mg/cm2

Interior Floor Vinyl White Intact 0.1 mg/cm2

Interior Wall Panel Wood White Intact 0.1 mg/cm2

Interior Door Frame Metal Blue Intact 0.1 mg/cm2

Interior Floor Vinyl Brown Intact 0.1 mg/cm2

Interior Column Drywall White Intact 0.1 mg/cm2

Interior Column Drywall White Intact 0.2 mg/cm2

Interior Window Sill Metal White Intact 0.4 mg/cm2

Interior Window Sill Metal White Intact 0.2 mg/cm2

Interior Baseboard Wood Blue Intact 0.1 mg/cm2

Interior Baseboard Wood Blue Intact 0.1 mg/cm2

Interior Lower Wall Plaster White Intact 0.6 mg/cm2

Interior Lower Wall Plaster White Intact 0.2 mg/cm2

Interior Pipe Metal Red Intact 1 mg/cm2

Interior HVAC Metal Gray Intact 0.2 mg/cm2

Interior HVAC Metal Gray Intact 0.1 mg/cm2

Interior HVAC Metal Beige Intact 0.1 mg/cm2

Interior Floor Concrete Gray Intact 0.1 mg/cm2

Interior Lower Wall Stucco White Intact 0.1 mg/cm2

Interior Lower Wall Stucco White Intact 0.1 mg/cm2

Interior Floor Vinyl White Intact 0.1 mg/cm2

Interior Door Frame Metal Blue Intact 0.1 mg/cm2

Interior Wall Panel Metal White Intact 0.1 mg/cm2

Interior Wall Panel Metal White Intact 0.1 mg/cm2

Interior Lower Wall Metal White Intact 0.7 mg/cm2

Interior Lower Wall Metal White Intact 0.7 mg/cm2

Interior Lower Wall Metal White Intact 0.5 mg/cm2

Interior Floor Vinyl Green Intact 0.1 mg/cm2

Interior Floor Vinyl Brown Intact 0.1 mg/cm2

Interior Window Sill Wood White Intact 0.1 mg/cm2

Exterior Lower Wall Plaster White Intact 0.1 mg/cm2

Exterior Lower Wall Plaster White Intact 0.1 mg/cm2

Exterior Door Metal White Intact 0.2 mg/cm2

Exterior Door Metal White Intact 0.2 mg/cm2

Exterior Door Frame Metal Green Intact 0.1 mg/cm2

Exterior Door Frame Metal Green Intact 0.2 mg/cm2

Exterior Door Frame Metal Purple Intact 0.1 mg/cm2

Exterior Column Concrete Purple Intact 0.5 mg/cm2

Exterior Column Concrete Purple Intact 0.6 mg/cm2

Exterior Door Metal Beige Intact 0.4 mg/cm2

Exterior Door Metal Beige Intact 0.4 mg/cm2

Exterior Door Frame Metal Gray Intact 0.2 mg/cm2

Exterior Door Frame Metal Gray Intact 0.1 mg/cm2

Interior Lower Wall Drywall White Intact 0.1 mg/cm2

Interior Column Concrete White Intact 0.3 mg/cm2

Interior Column Concrete White Intact 0.2 mg/cm2

Interior Door Wood Varnish Intact 0.1 mg/cm2

Interior Door Wood Varnish Intact 0.1 mg/cm2

Interior Door Frame Metal White Intact 0.1 mg/cm2

Interior Door Frame Metal White Intact 0.1 mg/cm2

Interior Pipe Metal White Intact 0.1 mg/cm2

Interior Pipe Metal White Intact 0.1 mg/cm2

Interior Floor Concrete Gray Intact 0.3 mg/cm2

Interior Floor Concrete Blue Intact 0.2 mg/cm2

Interior Floor Concrete Blue Intact 0.1 mg/cm2

Interior Lower Wall Wood Blue Intact 0.2 mg/cm2

Interior Lower Wall Wood Blue Intact 0.1 mg/cm2

Interior Door Wood White Intact 0.1 mg/cm2

Interior Door Wood White Intact 0.1 mg/cm2

Interior Door Frame Wood White Intact 0.2 mg/cm2

Interior Door Frame Wood White Intact 0.1 mg/cm2

Interior Door Metal Blue Intact 0.1 mg/cm2

Interior Lower Wall Drywall White Intact 0.1 mg/cm2

Interior Ceiling Concrete White Intact 0.4 mg/cm2

Interior Ceiling Concrete White Intact 0.3 mg/cm2

Interior Conduit Metal White Intact 0.4 mg/cm2

Exterior Floor Terrazzo Black Intact 0.1 mg/cm2

Exterior Floor Terrazzo Black Intact 0.1 mg/cm2

Exterior Overhang Stucco White Intact 0.1 mg/cm2

Exterior Column Stucco Purple Intact 0.1 mg/cm2

Exterior Column Stucco Purple Intact 0.2 mg/cm2

Exterior Door Metal Beige Intact 0.3 mg/cm2

Exterior Door Metal Beige Intact 0.3 mg/cm2

Exterior Door Frame Metal Purple Intact 0.7 mg/cm2

Exterior Door Frame Metal Purple Intact 0.7 mg/cm2

Exterior Window Metal Red Intact 0.2 mg/cm2

Exterior Window Metal Red Intact 0.2 mg/cm2

Bold = Lead Based

Devices with Potential Hazardous Materials

MATERIAL CONTAMINANT ESTIMATED QUANTITY

Fluorescent Tubes (4' Length) Universal Waste 784

Other Non-Incandescent Lamps Universal Waste 70

Batteries: Emergency Lights & Exit Signs Universal Waste 35

Light Fixture Ballasts Polychlorinated Biphenyls or E-

Waste

Water Coolers/Fountains Ozone Depleting Chemicals 2

Halon System (1301) Ozone Depleting Chemicals 1

Smoke Detectors Low-level Radiation or E-Waste 100

ASBESTOS SAMPLING INVENTORY

HOMOGENEOUS ID MATERIAL DESCRIPTION # OF SAMPLES

A Spray Applied Acoustical Ceiling White, Ceiling 5

B Basecove/Mastic 4" Black/Beige 2

C Vinyl Floor Tile/Mastic 9" Light Brown/Black 4

D Mastic Yellow, Carpet 2

E Flooring Black, Terrazzo 2

F Concrete/Grout Beige, Rough, Beige, Wall 2

G Paint/Plaster White/White 7

H Vinyl Floor Tile/Mastic 12" Black/Yellow 2

I Basecove/Mastic 4" Gray/Brown 2

J Mortar/Grout White/White, Ceramic Wall 2

K Mortar/Grout White/White, Floor 2

L Mastic Black, Mirror 2

M Jacketing Beige, Pipe 2

N Fireproofing White, Columns, Beams, Walls & Ceiling 7

O Wallboard/Joint Compound White/White 5

P Vinyl Sheet Flooring/Mastic Beige, Pebble Pattern 2

Q Mastic Yellow, Wainscot, "FRP" 1

R Basecove/Mastic 4" Blue/Beige 2

S Basecove/Mastic 4" Brown/Beige 2

T Vinyl Floor Tile/Mastic 12" White/Yellow & Black 2

U Acoustical Ceiling Panel 2'x2'White, Textured Black Specs 2

V Vinyl Floor Tile/Mastic 12" White, Streaks/Black (Multi- Layer) 2

W Temp Wall Insulation White, Metal 2

X Basecove/Mastic 4" Maroon/Beige 2

Y Temporary Wall White, Walls 2

Z Sealant Black, Interior Window 2

AA Insulation 3" OD, White, Fittings 3

BB Insulation 6" OD, White, Fittings 3

CC Sealant Gray, HVAC Unit 2

DD Flex Connector Black, HVAC 1

EE Sealant White, HVAC, Outer 2

FF Sealant White, HVAC, Inner Seam 2

GG Paint/Stucco White/Gray 3

HH Concrete Gray, Structural 2

II Vinyl Floor Tile/Mastic 12" Brown/White 2

JJ Mastic White, Sink 1

KK Vinyl Floor Tile/Mastic 2'x2' Brown/Yellow 1

LL Mastic Black & Yellow, Computer Floor 2

MM Computer Floor 2'x2' White/Red 2

NN Sealant Gray, Wall Panel 2

OO Vinyl Floor Tile/Mastic 12" Olive Green/Black 4

PP Vinyl Sheet Flooring/Mastic Brown/Black 2

QQ Mortar/Grout Gray/Gray, Floor 1

RR Vapor Barrier Brown, Stucco Walls 2

SS Acoustical Ceiling Panel 2'x2' White, Solid 2

TT Wallboard/Joint Compound White/White, "Patina" Unfinished 2

UU Firestop Brown 2

VV Tape White, Duct 2

WW Texture Coat White, Medium 3

XX Paint/Stucco Beige/Gray, Exterior 3

YY Sealant White, Window Frame 2

ZZ Cement Panel Gray, Behind Metal, Under Windows Assumed

A3 Sealant Gray, Store Front 2

B3 Sealant Gray, Window Frame 2

C3 Glazing Black, Window 2

CITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

CITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

ASBESTOS SAMPLING LOCATIONS

vetech Callout E02 vetech Callout D01 vetech Callout B02 vetech Callout E01 vetech Callout A04 vetech Callout A05 vetech Callout A02 vetech Callout B01 vetech Callout A01 vetech Callout F01 vetech Callout A03 vetech Callout F02 vetech Callout N05 vetech Callout O01 vetech Callout N03 vetech Callout I01 vetech Callout H01 vetech Callout C01 vetech Callout U02 vetech Callout C02 vetech Callout N02 vetech Callout M01 vetech Callout N04 vetech Callout U01 vetech Callout G01 vetech Callout S01 vetech Callout J02 vetech Callout X02 vetech Callout J01 vetech Callout N01 vetech Callout L01 vetech Callout G02 vetech Callout V01 vetech Callout V02 vetech Callout S02 vetech Callout T01 vetech Callout N06 vetech Callout K02 vetech Callout G04 vetech Callout H02 vetech Callout G03 vetech Callout I02 vetech Callout D02 vetech Callout G05 vetech Callout G06 vetech Callout G07 vetech Callout I02 vetech Callout K01 vetech Callout L01 vetech Callout L02 vetech Callout M02 vetech Callout O02 vetech Callout P01 vetech Callout P02 vetech Callout Q01 vetech Callout T02 chris Typewriter

FIRST FLOOR PARTIAL

SAMPLE LOCATION DRAWING

chris Typewriter

455 COUNTY CENTER

REDWOOD CITY

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

CITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

vetech Callout R01 vetech Callout

AA01

vetech Callout Z01 vetech Callout Z02 vetech Callout Y02 vetech Callout X02 vetech Callout Y01 vetech Callout X01 vetech Callout W02 vetech Callout W01 vetech Callout R02 vetech Callout

BB03

vetech Callout

BB02

vetech Callout

BB01

vetech Callout

AA03

vetech Callout

AA02

vetech Callout

GG02

vetech Callout

GG01

vetech Callout

EE02

vetech Callout

EE01

vetech Callout

DD01

vetech Callout

CC02

vetech Callout

CC01

vetech Callout

HH01

vetech Callout

HH02

vetech Callout

GG03

vetech Callout

MM02

vetech Callout

MM01

vetech Callout

LL02

vetech Callout

LL01

vetech Callout

KK02

vetech Callout

KK01

vetech Callout

JJ01

vetech Callout

II02

vetech Callout

II01

vetech Callout

OO02

vetech Callout

OO01

vetech Callout

NN02

vetech Callout

NN01

vetech Callout

OO03

vetech Callout

OO04

vetech Callout X01 vetech Callout C03 vetech Callout C04 chris Typewriter

455 COUNTY CENTER

REDWOOD CITY

chris Typewriter

FIRST FLOOR PARTIAL

SAMPLE LOCATION DRAWING

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

CITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

vetech Callout

PP01

vetech Callout

SS02

vetech Callout

SS01

vetech Callout

RR02

vetech Callout

RR01

vetech Callout

QQ01

vetech Callout

PP02

vetech Callout

XX01

vetech Callout

YY02

vetech Callout

YY01

vetech Callout

XX03

vetech Callout

XX02

vetech Callout C301 vetech Callout B301 vetech Callout A302 vetech Callout A301 vetech Callout C302 chris Typewriter

455 COUNTY CENTER

REDWOOD CITY

chris Typewriter

FIRST FLOOR PARTIAL

SAMPLE LOCATION DRAWING

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOFCITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

CITY OF SEASIDE

FORMER FORT ORD - PHASE I

AREA 1: HARDSCAPE AND ROOF

vetech Callout

TT01

vetech Callout

VV01

vetech Callout

WW03

vetech Callout

VV02

vetech Callout

WW01

vetech Callout

WW02

vetech Callout

UU02

vetech Callout

UU01

vetech Callout

TT02

chris Typewriter

BASEMENT

SAMPLE LOCATION DRAWING

chris Typewriter

455 COUNTY CENTER

REDWOOD CITY

Final Report

(EPA Method 40CFR, Part 763, Appendix E to Subpart E and EPA 600/R-93-116, Visual Area Estimation)

Bulk Asbestos Analysis NVLAP Lab Code: 101459-0

L1161Client ID:Vista Environmental Consultants B363823Report Number:Chris Bruns

Date Received:2984 Teagarden St.

09/19/24Date Analyzed:

09/19/24Date Printed:San Leandro, CA 94577

First Reported:

L1161241101006 - 455 County Center SGSFL Job ID:Job ID/Site:

Date(s) Collected: 09/16/2024

123Total Samples Submitted:

Total Samples Analyzed: 123

09/17/24

09/19/24

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

A01 12769750

Layer: Off-White Semi-Fibrous Material Chrysotile 7 %

Layer: Paint ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

A02 12769751

Layer: Off-White Semi-Fibrous Material Chrysotile 7 %

Layer: Paint ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

A03 12769752

Layer: Off-White Semi-Fibrous Material Chrysotile 7 %

Layer: Paint ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

A04 12769753

Layer: Off-White Semi-Fibrous Material Chrysotile 7 %

Layer: Paint ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

A05 12769754

Layer: Off-White Semi-Fibrous Material Chrysotile 7 %

Layer: Paint ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

B01 12769755

Layer: Black Non-Fibrous Material ND

Layer: White Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

3777 Depot Road, Suite 409, Hayward, CA 94545 | Phone: 510.887.8828 / 800.827.3274 Fax: 510.887.4218 | https://falaboratories.sgs.com

Report Number: B363823

Date Printed: 09/19/24Client Name: Vista Environmental Consultants

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

B02 12769756

Layer: Black Non-Fibrous Material ND

Layer: White Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

C01 12769757

Layer: Red-Brown Tile Chrysotile 7 %

Layer: Black Mastic ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

C02 12769758

Layer: Red-Brown Tile Chrysotile 7 %

Layer: Black Mastic ND

Asbestos (7%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

D01 12769759

Layer: Tan Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

D02 12769760

Layer: Tan Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

E01 12769761

Layer: Black Cementitious Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

E02 12769762

Layer: Black Cementitious Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

F01 12769763

Layer: Off-White Cementitious Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

F02 12769764

Layer: Off-White Cementitious Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

3777 Depot Road, Suite 409, Hayward, CA 94545 | Phone: 510.887.8828 / 800.827.3274 Fax: 510.887.4218 | https://falaboratories.sgs.com

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

G01 12769765

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

G02 12769766

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

G03 12769767

Layer: White Plaster ND

Layer: Off-White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

G04 12769768

Layer: Off-White Plaster ND

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

G05 12769769

Layer: Off-White Plaster ND

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

G06 12769770

Layer: Off-White Plaster ND

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

G07 12769771

Layer: Off-White Plaster ND

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

3777 Depot Road, Suite 409, Hayward, CA 94545 | Phone: 510.887.8828 / 800.827.3274 Fax: 510.887.4218 | https://falaboratories.sgs.com

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

H01 12769772

Layer: Black Tile ND

Layer: Yellow Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

H02 12769773

Layer: Black Tile ND

Layer: Yellow Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

I01 12769774

Layer: Grey Non-Fibrous Material ND

Layer: Off-White Mastic ND

Layer: Brown Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

I02 12769775

Layer: Grey Non-Fibrous Material ND

Layer: Tan Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

J01 12769776

Layer: White Non-Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

J02 12769777

Layer: White Non-Fibrous Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

K01 12769778

Layer: White Non-Fibrous Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

K02 12769779

Layer: White/Beige Non-Fibrous Material ND

Layer: Stones ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

L01 12769780

Layer: Black Semi-Fibrous Tar Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

3777 Depot Road, Suite 409, Hayward, CA 94545 | Phone: 510.887.8828 / 800.827.3274 Fax: 510.887.4218 | https://falaboratories.sgs.com

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

L02 12769781

Layer: Black Semi-Fibrous Tar Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

M01 12769782

Layer: Tan Fibrous Material ND

Layer: Off-White Fibrous Material ND

Layer: Foil ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (5 %) Fibrous Glass (90 %)

M02 12769783

Layer: Off-White Woven Material ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (95 %)

N01 12769784

Layer: Off-White Semi-Fibrous Material Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

N02 12769785

Layer: Off-White Semi-Fibrous Material Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

N03 12769786

Layer: White Fibrous Material ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (2 %) Fibrous Glass (90 %)

N04 12769787

Layer: Off-White Semi-Fibrous Material Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

N05 12769788

Layer: Off-White Semi-Fibrous Material Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

N06 12769789

Layer: Off-White Semi-Fibrous Material Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

N07 12769790

Layer: Off-White Semi-Fibrous Material Chrysotile 10 %

Asbestos (10%)Total Composite Values of Fibrous Components:

Cellulose (Trace)

3777 Depot Road, Suite 409, Hayward, CA 94545 | Phone: 510.887.8828 / 800.827.3274 Fax: 510.887.4218 | https://falaboratories.sgs.com

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

O01 12769791

Layer: White Drywall ND

Layer: White Joint Compound ND

Layer: Drywall Tape ND

Layer: White Joint Compound ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (20 %) Fibrous Glass (10 %)

O02 12769792

Layer: White Drywall ND

Layer: White Joint Compound ND

Layer: Drywall Tape ND

Layer: White Joint Compound ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (20 %) Fibrous Glass (10 %)

O03 12769793

Layer: White Drywall ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (20 %)

O04 12769794

Layer: White Drywall ND

Layer: White Joint Compound ND

Layer: Drywall Tape ND

Layer: White Joint Compound ND

Layer: Paint ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (20 %) Fibrous Glass (10 %)

P01 12769795

Layer: Tan Sheet Flooring ND

Layer: Fibrous Backing ND

Layer: Tan Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (20 %) Fibrous Glass (5 %) Synthetic (10 %)

P02 12769796

Layer: Tan Sheet Flooring ND

Layer: Fibrous Backing ND

Layer: Tan Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (20 %) Fibrous Glass (5 %) Synthetic (10 %)

Q01 12769797

Layer: Tan Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

3777 Depot Road, Suite 409, Hayward, CA 94545 | Phone: 510.887.8828 / 800.827.3274 Fax: 510.887.4218 | https://falaboratories.sgs.com

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

R01 12769798

Layer: Blue Non-Fibrous Material ND

Layer: White Mastic ND

Asbestos (ND)Total Composite Values of Fibrous Components:

Cellulose (Trace)

R02 12769799

Layer: Blue Non-Fibrous…

This is the start of the file's text. The full file is on GovTribe.