24023 Exhibit B - Technical Specifications.docx
DOCX document 290 KB Posted
- Attached to
- Variable Message Boards
- Solicitation number
- 24023
- Issued by
- Adams County, Asotin County, Benton County, Chelan County, Clallam County, Clark County, Columbia County, Cowlitz County, Douglas County, Ferry County, Franklin County, Garfield County, Grant County, Grays Harbor County, Island County, Jefferson County, King County, Kitsap County, Kittitas County, Klickitat County, Lewis County, Lincoln County, Mason County, Okanogan County, Pacific County, Pend Oreille County, Pierce County, San Juan County, Skagit County, Skamania County, Snohomish County, Spokane County, Stevens County, Thurston County, Wahkiakum County, Walla Walla County, Whatcom County, Whitman County, Yakima County, Asotin City, Clarkston City, Clarkston Heights-Vineland CDP, West Clarkston-Highland CDP, Benton City, Chelan City, Chelan Falls CDP, Clallam Bay CDP, Lewisville CDP, Rock Island City, Pacific Beach CDP, Whidbey Island Station CDP, Mercer Island City, Pacific City, Bainbridge Island City, Kingston CDP, Kitsap Lake CDP, Kittitas City, Klickitat CDP, Okanogan City, Anderson Island CDP, Fort Lewis CDP, Fox Island CDP, Herron Island CDP, Ketron Island CDP, North Fort Lewis CDP, Raft Island CDP, Stevenson City, Hat Island CDP, Lake Stevens City, Snohomish City, Spokane City, Spokane Valley City, Puget Island CDP, Garfield Town, Yakima City, Washington
About this file
This document is the Technical Specifications Exhibit B for a competitive solicitation for Variable Message Boards issued by the State of Washington Department of Enterprise Services. The contract categories include Truck Mounted Arrow Boards, Truck Mounted 2-Line and 3-Line Matrix Boards, and Trailer Mounted Full-Matrix and Line-Matrix Message Boards. The specification details mandatory requirements for the various categories of Variable Message Boards, including requirements for the trailers, displays, sign construction, controllers, and other features. This is a statewide contract available for eligible purchasers in Washington state, including counties, cities, and other jurisdictions. The contract term is not specified.
The pricing terms, set asides, funding sources, and other commercial terms are not detailed in this technical specification document. It focuses solely on the detailed technical requirements for the Variable Message Boards. No information is provided about the incumbent contractors, current environment, or award process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24023_Exhibit-A-2-Bidder'sProfile.docx | DOCX document | |
| 24023_Exhibit-E-PCBCertification.docx | DOCX document | |
| 24023_SolAmd1.docx | DOCX document | |
| 24023_SolAmd2.docx | DOCX document | |
| 24023 Competitive SolicitationV2.docx | DOCX document | |
| 24023 Competitive SolicitationV3.docx | DOCX document | |
| 24023 Exhibit-D-PurchasingAgreementV2.docx | DOCX document | |
| 24023_Exhibit-A-1-Bidder's CertificationV2.docx | DOCX document | |
| 24023_Exhibit-C-BidPriceV3.xlsx | XLSX spreadsheet | |
| 24023_QA2.docx | DOCX document | |
| 24023 Exhibit B - Technical SpecificationsV2.docx | DOCX document | |
| 24023_Exhibit-C-BidPrice.xlsx | XLSX spreadsheet | |
| 24023_Exhibit-C-BidPriceV2.xlsx | XLSX spreadsheet | |
| 24023_SolAmd3.docx | DOCX document | |
| 24023_Exhibit-A-1-Bidder's Certification.docx | DOCX document | |
| 24023 Competitive Solicitation.docx | DOCX document | |
| 24023_Exhibit-D-PurchasingAgreement.docx | DOCX document | |
| 24023_PreBid.pdf | ||
| 24023_QA.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT B – TECHNICAL SPECIFICATIONS
| Competitive Solicitation: |
| 24023 Variable Message Boards |
| Bidder: |
| _________________________________ |
Type/print full legal name of bidder company
Instructions:
1. Add Bidder’s business name above and follow the instructions below. Please note: Not following any of the instructions may result in the bid being deemed to be non-responsive.
2. Bidder Compliance. Review the Mandatory Specifications for Variable Message Boards and, as appropriate, in the Bidder Compliance column, mark either ‘Yes’ or ‘No’ depending on whether Bidder’s products meet such specification. If Bidder is NOT submitting a bid for the specific category for such specification, mark ‘N/A.’ Bidders must mark a response for each specification. If any specification does not have a response in the Bidder Compliance column, the bid may be non-responsive.
3. Written Response. If a Bidder can offer an equivalent alternative solution to what a certain specification states, or if Bidder can only partially meet the stated specification, the Bidder must provide a written response that addresses how Bidder meets that specification in the Written Response column.
4. Assessment.
a. Pass/Fail: Bidders must meet each of the Mandatory Minimum Specifications for Variable Message Boards. If Bidder selects ‘No’ for any of these specifications, or if Bidder’s proposed alternative or partial solution (if applicable) is determined to be insufficient, the bid will be deemed to be non-responsive, and the bid will be disqualified from further consideration.
b. In Bidder’s Written Response column, Bidder may provide a written response for any requirement marked ‘No.’
5. Supporting Information. Enterprise Services may request additional information to help verify the information provided by Bidder in this exhibit. A Bidder’s failure to provide requested information to Enterprise Services within two (2) business days may result in disqualification.
6. Bidder’s Commitments. Please note that Bidder’s responses, as applicable, will be added to the resulting Contract. Accordingly, Bidders are cautioned to indicate commitments that they can meet throughout the term of the Contract. If a Bidder/Contractor is not able to honor these commitments throughout the Contract term, Bidder/Contractor may be subject to early Contract termination that could impact their ability to contract with State agencies in the future. Please see Exhibit D – Contract.
7. Submit the exhibit as a Microsoft Word document and without modifying the formatting. If you need to print out this document for any reason, please note this document is size Legal 8.5” x 14”.Bidder’s
| REQ ID |
| Specification |
| Type |
| Bidder Compliance |
| Written Response |
| 1. |
| This Mandatory Specification applies to bids for the following contract categories: |
· All Categories
GENERAL SPECIFICATIONS FOR VARIABLE MESSAGE BOARDS:
· The unit Must be delivered with all manuals, (operator, service, parts) as a PDF download, QR code, or thumb drive upon request.
· Exterior Finish:
· There Must be no welding scale, roughness, sharp corners, or rust stains on the unit.
· The sign display cabinet Must be painted with a black powder coat.
Pass/Fail ☐ Yes ☐ No ☐ N/A No response required
| 2. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 5 – Full Matrix Small Changeable Message Sign (Trailer Mounted)
· Category 6 – Full Matrix Mid-Size Changeable Message Sign (Trailer Mounted)
· Category 7 – Full Matrix Large Changeable Message Sign (Trailer Mounted)
· Category 8 – Line Matrix Small Changeable Message Sign (Trailer Mounted)
· Category 9 – Line Matrix Mid-Size Changeable Message Sign (Trailer Mounted)
· Category 10 – Line Matrix Large Changeable Message Sing (Trailer Mounted)
· Category 11 – Full Matrix 5-Color Message Sign (Trailer Mounted)
SPECIFICATION:
· Trailer:
· Trailer Must be designed to transport the sign.
· The sign trailer’s axle, suspension, wheels and tires, and highway lighting Must conform to the Federal Motor Vehicle Safety Standards (FMVSS).
· Hitch Must have a lockable 2-5/16-inch ball with a three-inch inner diameter pintle combination coupler with safety chains.
· Trailer Must be equipped with electric brakes if required by FMVSS.
· Must have adjustable leveling or stabilizer jacks on all four corners or equivalent.
· The draw bar Must be equipped with a wheel type, adjustable height folding jack.
· Battery enclosure(s) Must be constructed of non-corrosive material, ventilated and lockable.
| Pass/fail |
| ☐ Yes |
☐ No ☐ N/A No response required
| 3. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 1 – 2 Line Message Sign (Truck Mounted)
· Category 2 – 3 Line Message Sign (Truck Mounted)
SPECIFICATION:
· The sign and the controller must meet SAE J1455 which requires the board not to interfere with radio frequencies. This will include 700, 800 MHZ, frequencies as well as CB radios.
· Displays:
· Must be capable of displaying (two or three) lines of amber-yellow colored text consisting of at least eight 10- or 12-inch-high characters.
· Must be capable of displaying a full screen view of standard highway symbols arrows, chevrons, and 4 corner warning lights.
· Must be capable of displaying one line of amber colored text consisting of four characters, for example STOP.
· Must be displayed using LED’s. No moving parts in the displays. The message displayed on the sign must be clearly legible, to the driving public, from a distance equal to or greater than 650 feet for day and night conditions using 10- or 12-inch characters.
· Must be capable of linking 3 or more messages for a sequence display.
· Sign Construction:
· The message sign cabinet must be constructed of a lightweight material, such as aluminum.
· State material used in Optional Written Response box.
· The display side of the message sign must have a clear, scratch and UV resistant polycarbonate window.
· The dimensions of the sign must be the manufacturers standard.
· Sign must have a sealing gasket between the window and the cabinet that seals out the weather elements and minimizes window vibration shock.
· Enclosure must be thermostatically controlled to prevent damage and failure due to overheating. Vents and fan(s) to be sealed to keep out weather elements.
· The state of WA will accept a sign without thermostatic controls however, the sign must have the ability to operate in temperatures of -20 degrees F to +110 degrees F without damage to the sign or the enclosure. This must be annotated in the manufacturer’s sales literature.
· Must include the manufacturer’s standard mounting hardware and actuator.
· The actuator Must be capable of moving the sign to a vertical (deployed) position and to the horizontal (stowed or travel) position from inside the vehicle cab.
· Controller:
· Must be the manufacturer’s standard controller.
· The controller must contain 50 or more of the manufacturer’s standard pre-programmed messages.
· The controller must provide space for 40 or more user designed display messages.
| Pass/Fail |
| ☐ Yes |
☐ No ☐ N/A No response required
| 4. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 3 – LED Arrow Board 3’x3’
SPECIFICATION:
· Board:
· Must be equipped with at least 25 high intensity LED lights.
· The arrows displayed on the sign must be clearly legible to the driving public from a distance equal to or greater than 1000 feet for both day and night conditions.
· The unit must receive its power from the chassis.
· The message sign cabinet must be constructed of a lightweight material, such as aluminum.
· State material being used in Written Response box.
· must have all mounting hardware needed for installation onto a pickup.
· State mounting location preference being used in Written Response box
· Must have a manual and automatic dimmer mode
· Must have internal support brackets to prevent deformation or buckling of the board.
· Operating voltage to be 12 VDC.
· Must have the following modes:
· Sequential chevron right or left
· Sequential stem arrow right or left
· Sequential head arrow right or left
· Single flashing arrow right or left
· Double flashing arrow
· Caution corners (four corner)
· Caution Bar
· Alternating diamond caution
· Test (If applicable)
· Remote Control:
· Must be a weather-tight enclosure with software and hardware necessary to operate the board.
· Controller Must have a 35-foot control cable assembly.
| Pass/fail |
| ☐ Yes |
☐ No ☐ N/A Response Required
| 5. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 4 – Full Matrix Mid-Size for Small Trucks (Truck Mounted)
· The sign and the controller Must meet SAE J1455 which requires the board not to interfere with radio frequencies. This will include 700, 800 MHZ, frequencies as well as CB radios.
· Displays:
· Sign to be equipped with an automatic dimming system.
· Must be capable of displaying three lines of amber colored text consisting of 8 or more characters per line using various character sizes.
· Must be capable of displaying MUTCD part VI work zone graphics and arrow board functions.
· Must be capable of displaying one line of amber colored text consisting of four characters, for example STOP.
· The message displayed on the sign must be clearly legible, to the driving public, from a distance equal to or greater than 1000 feet for day and night conditions using the manufacturer’s standard sized characters on three lines.
· Must be capable of linking 3 or more messages for a sequence display.
· Sign Construction:
· The message sign cabinet Must be constructed of a lightweight material, such as aluminum.
· State material used in Optional Written Response box.
· The display side of the message sign Must have a clear, scratch, and UV resistant polycarbonate window.
· The sign Must have a sealing gasket between the window and the cabinet that seals out the weather elements and minimizes window vibration shock.
· The sign enclosure Must be thermostatically controlled to prevent damage and failure due to overheating. Vents and fan(s) to be sealed to keep out weather elements.
· Must have the ability to operate in temperatures of -20 degrees F to +110 degrees F without damage to the sign or the enclosure. This must be annotated in the manufacturer’s sales literature.
· The sign Must be deployed by a powered lift system or a manually operated lift mechanism. Vendors are encouraged to provide option pricing for a power lift system if a manual system is being bid.
· State what lift mechanism is being bid in Written Response box.
· The sign Must follow MUTCD 6F60, paragraph 26.
· The mounting of portable changeable message signs on a trailer, truck, Must be such that the bottom of the message sign Must be a minimum of 7 feet above the roadway in urban areas and 5 feet above the roadway in rural areas when it is in the operating mode.
· Sign stow height, as measured from the ground to the top edge of the sign, Must be equal to or less than: 98”
· Sign Must have a deep cycle battery array capable of operating the sign for 168 hours or more without sunlight.
· Battery re-charges Must be accomplished with a 160-watt solar panel array that automatically points upward.
· Must be equipped with AC power battery charging system.
· Control Center:
· Controller Must be NTCIP compliant located in a lockable enclosure.
· Controller Must have a high resolution LCD screen or approved equal.
· Must have a remote control capabilities, i.e. WIFI or cellular.
· Must contain at least 100 of the manufacturer’s pre-programmed messages.
· Must provide space for at least 100 user designed display messages.
· The board Must have the ability to link 3 or more messages from the manufacturer’s pre-programmed or stored messages.
· Must have all mounting hardware needed for installation onto a pickup.
· State mounting location preference being used in Written Response box.
| Pass/fail |
| ☐ Yes |
☐ No ☐ N/A Response required
| 6. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 5 – Full Matrix Small Changeable Message Sign (Trailer Mounted)
· Category 6 – Full Matrix Mid-Size Changeable Message Sign (Trailer Mounted)
· Category 7 – Full Matrix Large Changeable Message Sign (Trailer Mounted)
SPECIFICATION:
· The sign and the controller Must meet SAE J1455 which requires the board not to interfere with radio frequencies. This will include 700, 800 MHZ, frequencies as well as CB radios
· Display:
· Sign to be equipped with an automatic dimming system.
· Must be capable of displaying three lines of amber colored text consisting of 8 or more characters per line using various character sizes.
· Must be capable of displaying MUTCD part VI work zone graphics and arrow board functions.
· Must be capable of displaying one line of amber colored text consisting of four characters, for example STOP.
· The message displayed on the sign Must be clearly legible, to the driving public, from a distance equal to or greater than 1000 feet for day and night conditions using the manufacturer’s standard sized characters on three lines.
· Must be capable of linking 3 or more messages for a sequence display.
· Sign Construction:
· The message sign cabinet Must be constructed of a lightweight material, such as aluminum.
· State material used in Optional Written Response box.
· The display side of the message sign Must have a clear, scratch, and UV resistant polycarbonate window.
· The dimensions of the display panel Must be equal to or less than:
· 82” in width and 49” in height, (for small size)
· 105” in width and 66” in height, (for mid-size)
· 145” in width and 83” in height, (for large size).
· The sign Must have a sealing gasket between the window and the cabinet that seals out the weather elements and minimizes window vibration shock.
· The sign enclosure Must be thermostatically controlled to prevent damage and failure due to overheating. Vents and fan(s) to be sealed to keep out weather elements.
· Must have the ability to operate in temperatures of -20 degrees F to +110 degrees F without damage to the sign or the enclosure. This must be annotated in the manufacturer’s sales literature.
· The sign Must be deployed by a powered lift system or a manually operated lift mechanism. Vendors are encouraged to provide option pricing for a power lift system if a manual system is being bid.
· State what lift mechanism would be offered in Optional Written Response box. ¬
· The sign Must follow MUTCD 6F60, paragraph 26. The mounting of portable changeable message signs on a trailer, a large truck, or a service patrol truck Must be such that the bottom of the message sign Must be a minimum of 7 feet above the roadway in urban areas and 5 feet above the roadway in rural areas when it is in the operating mode.
· Sign stow height, as measured from the ground to the top edge of the sign, Must be equal to or less than:
· 98” for small size, or
· 114” for mid and large size.
· Sign Must have a deep cycle battery array capable of operating the sign for 168 hours or more without sunlight.
· Battery re-charges Must be accomplished with a 160-watt solar panel array that automatically points upward.
· Must be equipped with AC power battery charging system.
· Control Center:
· Controller Must be NTCIP compliant located in a lockable enclosure.
· Controller Must have a high-resolution LCD screen or approved equal.
· Must have a remote-control capabilities, i.e. WIFI or cellular.
· Must contain at least 100 of the manufacturer’s pre-programmed messages.
· Must provide space for at least 100 user designed display messages.
· The board Must have the ability to link 3 or more messages from the manufacturer’s pre-programmed or stored messages.
| Pass/fail |
| ☐ Yes |
☐ No ☐ N/A No response required
| 7. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 8 – Line Matrix Small Changeable Message Sign (Trailer Mounted)
· Category 9 – Line Matrix Mid-Size Changeable Message Sign (Trailer Mounted)
· Category 10 – Line Matrix Large Changeable Message Sing (Trailer Mounted)
· The sign and the controller Must meet SAE J1455 which requires the board not to interfere with radio frequencies. This will include 700, and 800 MHZ, frequencies as well as CB radios.
· Displays:
· Must be equipped with an automatic dimming system.
· Must be capable of displaying three lines of amber colored text consisting of:
· 8 or more (for small size)
· 6 or more (for mid and large sizes)
· characters per line using various character sizes.
· Must be capable of displaying MUTCD part VI arrow board functions.
· The message displayed on the sign Must be clearly legible, to the driving public, from a distance equal to or greater than 1000 feet for both day and night conditions using the manufacturers standard sized characters on three lines.
· Must be capable of displaying one line of amber colored text consisting four characters, for example STOP.
· Must be capable of linking 3 or more messages for a sequence display.
· Sign Construction:
· The message sign cabinet Must be constructed of a lightweight material, such as aluminum.
· State material used in Optional Written Response box.
· The display side of the message sign Must have a clear, scratch and UV resistant polycarbonate window.
· The dimensions of the display panel Must be equal to or less than:
· 82” in width and 49” in height, (for small size)
· 105” in width and 66” in height, (for mid-size)
· 145” in width and 83” in height, (for large size).
· The sign Must have a seal between the window and the cabinet that seal out the weather elements and minimizes window vibration shock.
· The sign enclosure Must be thermostatically controlled to prevent damage and failure due to overheating. Vents and fan(s) to be sealed to keep out weather elements.
· Must have the ability to operate in temperatures of -20 degrees F to +110 degrees F. This must be annotated in the manufacturer’s specifications.
· The sign Must be deployed by a powered lift system or a manually operated lift mechanism. Vendors are encouraged to provide option pricing for a power lift system if a manual system is being bid.
· State what lift mechanism is being bid in Optional Written Response box. ¬
· The sign Must follow MUTCD 6F60, paragraph 26. The mounting of portable changeable message signs on a trailer, a large truck, or a service patrol truck Must be such that the bottom of the message sign Must be a minimum of 7 feet above the roadway in urban areas and 5 feet above the roadway in rural areas when it is in the operating mode.
· Sign stow height Must be equal to or less than 108 inches measured from the ground to top edge of sign.
· Sign Must have a deep cycle battery array capable of operating the sign for 168 hours or more without sunlight.
· Battery re-charges Must be accomplished with a 160 watt solar panel array that automatically point upward.
· Must be equipped with AC power battery charging system.
· Control Center:
· Controller Must be NTCIP compliant located in a secure enclosure.
· Controller Must have a high-resolution LCD screen or an approved equal.
· Must have a remote-control capability, i.e. WIFI or Cellular.
· Must contain at least 100 or more of the manufacture’s pre-programmed messages.
· Must provide space for at least 100 or more user designed display messages.
· The board Must have the ability to link 3 or more messages from the manufacturer’s preprogrammed messages or stored messages.
| Pass/fail |
| ☐ Yes |
☐ No ☐ N/A No response required
| 8. |
| This Mandatory Specification applies to bids for the following contract categories: |
· Category 11 – Full Matrix 5-Color Message Sign (Trailer Mounted)
· The sign and the controller Must meet SAE J1455 which requires the board not to interfere with radio frequencies. This will include 700, and 800 MHZ, frequencies as well as CB radios.
· Display:
· Bidder Must provide Five color, full-matrix display for text and graphics
· Bidder Must be in accordance with NTCIP Version 2
· Bidder Must be equipped with an automatic dimming system
· The message displayed on the sign Must be clearly legible, to the driving public, from a distance equal to or greater than 1000 feet for both day and night conditions using the manufacturers standard sized characters on three lines.
· Sign Construction:
· The message sign cabinet Must be constructed of a lightweight material, such as aluminum.
· State material used in Optional Written Response box.
· The display side of the message sign Must have a clear, scratch and UV resistant polycarbonate window.
· The sign Must have a seal between the window and the cabinet that seal out the weather elements and minimizes window vibration shock.
· The sign enclosure Must be thermostatically controlled to prevent damage and failure due to overheating. Vents and fan(s) to be sealed to keep out weather elements.
· Must have the ability to operate in temperatures of -20 degrees F to +110 degrees F. This must be annotated in the manufacturer’s specifications.
· The sign Must be deployed by a powered lift system or a manually operated lift mechanism. Vendors are encouraged to provide option pricing for a power lift system if a manual system is being bid.
· State what lift mechanism is being bid in Optional Written Response box. ¬
· The sign Must follow MUTCD 6F60, paragraph 26. The mounting of portable changeable message signs on a trailer, a large truck, or a service patrol truck Must be such that the bottom of the message sign Must be a minimum of 7 feet above the roadway in urban areas and 5 feet above the roadway in rural areas when it is in the operating mode.
· Sign stow height Must be equal to or less than 108 inches measured from the ground to top edge of sign.
· Sign Must have a deep cycle battery array capable of operating the sign for 168 hours or more without sunlight.
· Battery re-charges Must be accomplished with a 160 watt solar panel array that automatically point upward.
· Must be equipped with AC power battery charging system.
· Control Center:
· Controller Must be NTCIP compliant located in a secure enclosure.
· Controller Must have a high-resolution LCD screen or an approved equal.
· Must have a remote-control capability, i.e. WIFI or Cellular.
· Must contain at least 100 or more of the manufacture’s pre-programmed messages.
· Must provide space for at least 100 or more user designed display messages.
· The board Must have the ability to link 3 or more messages from the manufacturer’s preprogrammed messages or stored messages.
| Pass/fail |
| ☐ Yes |
☐ No ☐ N/A No Response Required
| 9. |
| This Mandatory Requirement applies to bids for the following: |
· Available Features/Accessories
Required only if Bidder is including list of available Features and/or Accessories to Contract Categories.
REQUIREMENT:
· Bidders who include "Available Features/Accessories" for the supporting Category must provide a link or supporting documents for the listed MSRP.
| Pass/Fail |
| ☐ Yes |
☐ No ☐ N/A Response Required is including Available Features/Accessories
Return this exhibit to Procurement Coordinator at: