This solicitation seeks quotations for drydocking and ABS special survey services for the T.S. KENNEDY. The U.S. Department of Transportation Maritime Administration intends to award a firm fixed price contract to perform a USCG drydock exam, internal structural exam, and ABS special survey and drydock survey for the T.S. KENNEDY, a 15,500 HP steam ship measuring 536 feet long. The ship will be available for transit to the drydocking facility from September 3rd to November 15th 2022. Questions regarding the solicitation are due by July 20th. Interested contractors may request drawings referenced in the statement of work by July 18th. The solicitation also provides information on the DOT short-term lending program to finance transportation contracts for minority, women-owned, and disadvantaged businesses.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USTS KENNEDY
USTS1 KENNEDY
ABS Number 7914866 IMO Number 7704930
NO. 6 PORT DISTILLED WATER TANK
MMA Boston, MA
MARCH 2022
Prepared by Nestor Dimaya of:
TABLE OF CONTENTS
GENERAL PARTICULARS
GENERAL ARRANGEMENT
CAPACITY PLAN
SPECIAL INTEREST
NO. 6 PORT DISTILLED WATER TANK
GENERAL PARTICULARS
Name: USTS KENNEDY
ABS Number: 6704200
IMO Number: 6621662
Call Sign: KVMU
Official Number: 509652
Flag: United States of America
Port: Buzzards Bay, MA
Description: School Ship
Vessel Type: Special Purpose Vessel
Keel Laying Date: February 24, 1966
Delivery Date: July 1, 1967
Class Notation: A1, AMS
Additional Notation: Nil
Length Overall LOA 163.6 Meters
Length between Perpendiculars: 157.5 Meters
Tonnage
Design: 5630.1 Tons
Gross: 13886 Tons
CLASS SURVEYS
Annual Hull Survey 4: Due Date: May 27, 2022
Drydocking Survey: Due Date: May 27, 2022
Special Periodical Survey Hull 11: Due Date: May 27, 2023
Tailshaft Survey: Due Date: May 20, 2023
STATUTORY
Annual Load Line Survey 4: Due Date: May 27, 2022
Documentation of damage found in the no. 6 port distilled water tank. Previously discovered buckled floors with a soft curved rolled, slight surface indications found and addressed. Currently being monitored quarterly per annual year to ensure damage does not propagate or progress.
• The Port Engineer Mr. Jeffrey H. Brown and the Chief Engineer was in attendance with the local ABS surveyor and USCG inspectors and a verbal discussion agreed with quarterly monitoring of tank.
• Following report are the documented n.t. floors discovered with slight damage.
This vessel is not in the Alternate Compliance Program (ACP) with the US Coast Guard.
Guidelines for Structural Steel / Outfitting / Piping Assessment criteria were based on ABS rules, Part 7: Survey after construction using substantial diminution and gross defects, survey performed was for targeting steel repairs/renewals.
Inspection grading criteria for the ABS Hull Inspection and Maintenance Program were the guidelines used for criteria of repairs.
The ABS Coating Condition Guide for field surveyors was followed for coating assessment of existing surface coating systems.
ABS minimum wall thickness for steel pipes was followed for tolerance and based repair/s from wall thickness.
Respectfully submitted, Nestor Dimaya
GENERAL ARRANGEMENT
CAPACITY PLAN
WATER BALLAST TANKS 100% full - sp. Gr. 1.025 Tonnes
Cube Metric at 1.0 Kg Port Ctr Stbd
Fore Peak Tank 237 - St. 918.9 31 449 941.8 400 FWD Lower tank 202/204 - 218 678.2 23 950 695.1 410
No. 2 D.B. Wing Tank P 132 - 164 251.5 8 881 257.7 422 No. 2 D.B. Wing Tank S 132 - 164 241.5 8 526 247.7 421 No. 3 D.B. Wing Tank P 98 - 128 519.9 18 361 532.8 432 No. 3 D.B. Wing Tank S 98 - 128 519.9 18 361 532.8 431 No. 4 D.B. Center Tank P 98 - 128 273.0 9 640 279.8 432 No. 4 D.B. Center Tank S 98 - 128 225.8 8 008 232.4 431 No. 1 Lower Wing P 181 - 202 320.5 11 318 338.5 414 No. 1 Lower Wing S 181 - 202 320.5 11 318 328.5 413 No. 2 Lower Wing P 146 - 178 304.7 10 740 312.3 424 No. 2 Lower Wing S 146 - 178 295.2 10 424 302.5 423 No. 3 Lower Wing P 110 - 142 284.2 10 036 291.3 434 No. 3 Lower Wing S 110 - 142 272.9 9 637 279.7 433 No. 4 Lower Wing P 68 - 104 224.3 7 921 229.9 444 No. 4 Lower Wing S 68 - 104 296.6 10 474 304.0 443 No. 1 Upper Wing P 184 -237 734.4 25 935 752.7 416 No. 1 Upper Wing S 184 -237 750.3 26 496 769.0 415 No. 2 Upper Wing P 156 - 176 132.7 4 686 136.0 426 No. 2 Upper Wing S 156 - 176 130.8 4 619 134.0 425 No. 3 Upper Wing P 112 - 140 177.2 6 257 181.6 436 No. 3 Upper Wing S 112 - 140 173.3 6 120 177.6 435 No. 4 Upper Wing P 68 - 98 177.8 6 278 182.2 446 No. 4 Upper Wing S 68 - 98 185.6 6 554 190.2 445
Aft Peak Tank 1 - 17 771.9 27 259 791.1 Total of 25 Tanks TOTAL 9181.6 324 248 9412.1
FRESH WATER TANKS 100% full - sp. Gr. 1.000 Tonnes
Cube Metric at 1.0 Kg Port Ctr Stbd
FWD Upper Side (Port) 202 - 218 287.20 10 142 287 314 FWD Upper Side (Stbd) 202 - 218 287.20 10 142 287 313
Feed water tank 31 - 34 35.20 1 243 35 320 Total Tanks (3) TOTAL 609.60 21 527 609.6
COMPARTMENT FRAMES
CAPACITIES CODE NO.
Cube Feet
COMPARTMENT FRAMES
CAPACITIES CODE NO.
Cube Feet
CAPACITY PLAN
FUEL OIL TANKS 100% full - sp. Gr. 0.95 Tonnes
Cube Metric at 1.0 Kg Port Ctr Stbd
Fore Deep Tank (Port) 218 - 231 570.0 20 129 541.5 102 Fore Deep Tank (Stbd) 218 - 231 579.2 20 454 550.2 101
#1 D.B.T. (Port) 166 - 202 420.7 14 856 399.6 112 #1 D.B.T. (Stbd) 166 - 202 457.2 16 145 434.3 111
#2 D.B.T. (Center/Port) 130 - 166 562.7 19 871 534.5 122 #2 D.B.T. (Center/Stbd) 130 - 166 517.0 18 257 491.1 121
#3 D.B.T. (Port) 96 - 130 285.5 10 82 271.2 132 #3 D.B.T. (Stbd) 96 - 130 321.9 11 367 305.8 131
H.F.O. Settling (Port) 20 - 28 63.0 2 224 59.8 142 H.F.O. Service (Port) 28 - 35 59.0 2 83 56.0 144
#5 D.B. Wing F.O. Sludge (P) 35 - 64 200.0 7 62 190.2 152 #5 D.B. Wing F.O. Overflow (S) F.O. Overflow/Drain (Stbd) 35 - 64 186.3 6 579 176.9 151 Total Tanks (13) TOTAL 4,222.5 149 109 4,011.1
DIESEL OIL TANKS 100% full - sp. Gr. 0.85 Tonnes
Cube Metric at 1.0 Kg Port Ctr Stbd
No. 4 D.B. Wing (Port) 64 - 94 398.7 14 79 338.8 242 No. 4 D.B. Wing (Stbd) 64 - 94 398.7 14 79 338.8 241
D.O. Settling tank (Port) 20 - 24 26.3 928 22.3 262 D.O. Service tank (Stbd) 24 - 27 22.6 798 19.2 264
Total Tanks (4) TOTAL 846.3 29 884 719.3
Cube Feet
COMPARTMENT FRAMES
CAPACITIES CODE NO.
Cube Feet
COMPARTMENT FRAMES
CAPACITY PLAN
OTHER TANKS 100% full Tonnes
Cube Mtr at 1.0 Kg Port Ctr Stbd
L.O. System - sump Tk (Ctr) 35 - 61 72.3 2 553 500 L.O. Tank 1 (Port) 56 - 62 21.2 748 502 L.O. Tank 2 (Port) 56 - 62 21.2 748 504
Gen. Eng. L.O. Tank 1 (Port) 56 - 62 17.6 620 506 Gen. Eng. L.O. Tank 2 (Port) 56 - 62 16.7 589 508 Cyl. Oil Storage Tank 1 (Port) 56 - 62 28.6 1 ## 510 Cyl. Oil Storage Tank 2 (Port) 56 - 62 28.2 995 512 G.E. L.O. Drain Tank (Stbd) 27 - 31 4.9 173
Bilge Tank (Ctr) 20 - 31 86.8 3 65 600 Bilge Water (Stbd) 60 - 64 31.4 1 108 F.W. Drain Tank (Port) 62 - 64 10.0 353
Stern Tank F.W. Cooling (Ctr) 7 - 20 73.7 2 602 Sewage Collection Tank (Port) 39 - 40 21.1 748 632 Sewage Collection Tank (Stbd) 39 - 40 19.9 702 631
Separated Oil (Port) 35 - 36 9.5 335 Blended Oil Tank (Port) 27 - 31 35.5 1 253 D.O. for Truck (Stbd) 9 - 13 26.7 942
COMPARTMENT FRAMES
Cube Feet
SPECIAL INTEREST
AS OF 2012
NO. 6 PORT DISTILLED WATER TANK
Three N.T. Floors were discovered three shipyard special survey prior. Following sketches shows detail and locations of damage and actions performed to ensure detrimental members are within tolerance.
1. NOT TIGHT FLOOR 151 in way of the lightening hole Inboard. Section between the inner bottom tanktop and the bottom plate has a slight soft buckle ≈24" x 18" x 1/2". Adjacent Inner bottom longitudinal stiffener and the bottom longitudinal stiffener along with the vertical flatbar does not have any sign of deflection. Bottom plate in way of the floor does not have any indication of contact or inset. Damaged floor is surveyed quarterly by the Chief engineer to monitor if the damage has any propagation.
Defect/flaws found
- Floor cutout wrap weld to the inner bottom tanktop was fractured 1" outboard of the Inner Bottom
Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
- Floor Web fractured 1" in way of the cutout radius for IBL #1, not a thru fracture. Fractured was peened and NDE performed found wrap weld was acceptable and no indication exist.
- Floor rat hole snipe wrap weld inboard to the bottom plate was fractured 1-1/4" just outboard of Bottom Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
NO. 6 PORT DISTILLED WATER TANK
2. NOT TIGHT FLOOR 154 in way of the lightening hole Inboard. Section between the inner bottom tanktop and the bottom plate has a slight soft buckle ≈38" x 26" x 1/2". Adjacent Inner bottom longitudinal stiffener and the bottom longitudinal stiffener along with the vertical flatbar does not have any sign of deflection. Bottom plate in way of the floor does not have any indication of contact or inset. Damaged floor is surveyed quarterly by the Chief engineer to monitor if the damage has any propagation.
Defect/flaws found
- Floor cutout wrap weld to the inner bottom tanktop was fractured 1-1/2" outboard of the Inner
Bottom Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
- Floor Web fractured 1-1/2" in way of the cutout radius for IBL #1, not a thru fracture. Fractured was peened and NDE performed found wrap weld was acceptable and no indication exist.
- Floor rat hole snipe wrap weld inboard to the bottom plate was fractured 1" just outboard of Bottom Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
- Floor rat hole snipe wrap weld outboard to the bottom plate was fractured 1/2" just outboard of Bottom Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
3. NOT TIGHT FLOOR 157 in way of the lightening hole Inboard. Section between the inner bottom tanktop and the bottom plate has a slight soft buckle ≈16" x 18" x 1/2". Adjacent Inner bottom longitudinal stiffener and the bottom longitudinal stiffener along with the vertical flatbar does not have any sign of deflection. Bottom plate in way of the floor does not have any indication of contact or inset. Damaged floor is surveyed quarterly by the Chief engineer to monitor if the damage has any propagation.
Defect/flaws found
- Floor cutout wrap weld to the inner bottom tanktop was fractured 1" outboard of the Inner Bottom
Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
- Floor Web fractured 1/2" in way of the cutout radius for IBL #1, not a thru fracture. Fractured was peened and NDE performed found wrap weld was acceptable and no indication exist.
- Floor rat hole snipe wrap weld inboard to the bottom plate was fractured 1" just outboard of Bottom Long'l #1. Fractured was peened and NDE performed, found wrap weld was acceptable and no indication exist.
See following sketch for location and more details.
| GENERAL PARTICULARS 3 |
| GENERAL ARRANGEMENT 5 |
| CAPACITY PLAN 6 |
| SPECIAL INTEREST 9 |
| GENERAL PARTICULARS |
| GENERAL ARRANGEMENT |
| CAPACITY PLAN |
| SPECIAL INTEREST |
| NO. 6 PORT DISTILLED WATER TANK |