2 QAIRQMT_REPORT.pdf
PDF 84 KB Posted
- Attached to
- Pump Assemblies
- Solicitation number
- FA851725RRepairofMechanicalTransmissionAssembly
About this file
This is an AFMC Form 807 "Recommended Quality Assurance Provisions and Special Inspection Requirements" document for NSN 4320011740506VX. The form specifies source inspection and acceptance requirements, with both designated as "source" per DFARS 246.402 due to specific product features requiring government quality assurance at source.
The document indicates standard inspection requirements under FAR 52.246-2,-3,-4,-5 or -6 will apply. The criticality designator for contract performance surveillance is C. The item is a previous source procurement that does not require a quality pre-award survey or AFMC participation. The technical authority certifies that no Class I Ozone Depleting Substances are required. The form is signed by Steven J. Fazzini of the 410 SCMS/GUEA organization on October 10, 2019, with Daniel S. Reeves listed as Item Manager and Charles Wheeler as Equipment Specialist.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA851725Q0014 02 061825.pdf | ||
| 25-00011 PWS Final042425.pdf | ||
| Solicitation042425.pdf | ||
| FA851725Q0014.pdf | ||
| FA851725Q0014.pdf | ||
| 3 QAIRQMT_REPORT.pdf | ||
| PWS_JAN2825.pdf | ||
| 3 CRSAW_REPORT.pdf | ||
| 2 CRSAW_REPORT.pdf | ||
| 3 ITMDESC_REPORT.pdf | ||
| 4075111_PKGRQMT_REPORT.pdf | ||
| 1 CRSAW_REPORT.pdf | ||
| 2 ITMDESC_REPORT.pdf | ||
| 4 ITMDESC_REPORT.pdf | ||
| 4074969_TRNSPDATA_REPORT.pdf | ||
| 1 QAIRQMT_REPORT.pdf | ||
| 4 QAIRQMT_REPORT.pdf | ||
| 4 CRSAW_REPORT.pdf | ||
| 1 ITMDESC_REPORT.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RECOMMENDED QUALITY ASSURANCE PROVISIONS
AND SPECIAL INSPECTION REQUIREMENTS
1. PR / MIPR NUMBER
2. NATIONAL STOCK NUMBER
4320011740506VX
3. POINT OF INSPECTION
SOURCE DESTINATION
X
SEE DFARS 246.402
4. POINT OF ACCEPTANCE
SOURCE DESTINATION
X
5. ITEM MANAGER / PHONE
Reeves, Daniel S / 478-222-1651
6. EQUIPMENT SPEC / PHONE
Wheeler, Charles / 478-222-1392
7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS
CERTIFICATE OF CONFORMANCE
FAR 52.246-15
CONTRACT RESPONSIBILITY
FOR INSPECTION
FAR 52.246-1
X STANDARD INSPECTION
FAR 52.246-2,-3,-4,-5 OR -6
AS APPLICABLE TO CONTRACT
HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS
COMMERCIAL ITEM INSPECTION
FAR 52.212-4
OTHER (Describe in Block 8)
8. REMARKS
Fazzini, Steven JNAME: 10 OCT 2019DATE:
In accordance with DFAR 246.402, this product being acquired has specific features identified that make Government contract quality assurance at source necessary.
The recommended criticality designator for contract performance surveillance is C.
8a. OZONE DEPLETING SUBSTANCES (ODS)
X STATEMENT
"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN
ONLY BE MET BY THE USE OF A CLASS I ODS."
WAIVER (SEE AF FARS 5323)
NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.
9. QUALITY PRE-AWARD SURVEY
YES NEW SOURCE
X PREVIOUS SOURCEX NO
AFMC PARTICIPATION
RECOMMENDED
10. CODES
A. I&A
B. CQR
C
11. SIGNATURE OF TECHNICAL AUTHORITY
Fazzini, Steven J
ORGANIZATION / SYMBOL
410 SCMS / GUEA
PHONE
478-327-2790 / 497-2790
DATE
10 OCT 2019
Page 1 of 1AFMC FORM 807, 20060111, V1 Version 4Generated by PRPS using Jasper Reports on 30 Jan 2025