2 CRSAW_REPORT.pdf
PDF 97 KB Posted
- Attached to
- Pump Assemblies
- Solicitation number
- FA851725RRepairofMechanicalTransmissionAssembly
About this file
This is a Contract Repair Screening Analysis Worksheet (AFMC Form 762) dated March 28, 2024, for an axial piston pump (NSN 4320011740506VX, P/N 58313-90004-20) used in the B-1B/B-52 weapon systems and MHU-196/M and MHU-204/M end items.
The analysis indicates an annual repair quantity of 6 units with a latest repair cost of $3,815 per unit and an annual repair budget value of $22,890. The forecast unit price is $4,005.75. Previous contract repairs were performed by Motion Industries, Inc. (CAGE 4N240) in June 2020 and Textron Systems Corporation (CAGE 97384) in March 2011 and March 2002. The item is designated as a commercial item eligible for repair under FAR Part 12, does not require special tools/facilities or government furnished material, and is not classified as a critical safety item. No organic repair or DMISA repair capability currently exists. The RMC/RMSC code is R1/Z with an expiration date of October 7, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA851725Q0014 02 061825.pdf | ||
| 25-00011 PWS Final042425.pdf | ||
| Solicitation042425.pdf | ||
| FA851725Q0014.pdf | ||
| FA851725Q0014.pdf | ||
| PWS_JAN2825.pdf | ||
| 3 CRSAW_REPORT.pdf | ||
| 3 ITMDESC_REPORT.pdf | ||
| 4075111_PKGRQMT_REPORT.pdf | ||
| 2 QAIRQMT_REPORT.pdf | ||
| 3 QAIRQMT_REPORT.pdf | ||
| 1 QAIRQMT_REPORT.pdf | ||
| 4 QAIRQMT_REPORT.pdf | ||
| 4 CRSAW_REPORT.pdf | ||
| 1 ITMDESC_REPORT.pdf | ||
| 1 CRSAW_REPORT.pdf | ||
| 2 ITMDESC_REPORT.pdf | ||
| 4 ITMDESC_REPORT.pdf | ||
| 4074969_TRNSPDATA_REPORT.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART I (To be completed by PMS Seller)
1. FORM INITIATION DATE
28 MAR 2024
2. FORM PRIORITY
3. NSN
4320011740506VX
4. PART NUMBER
58313-90004-20
5. PART NUMBER CAGE CODE
97384
6. NOUN
PUMP,AXIAL PISTONS
7. ANNUAL REPAIR
QUANTITY
8. LATEST REPAIR COST
$3,815.0000
9. ANNUAL REPAIR
BUDGET VALUE
$22,890.00
10. FORECAST UNIT
PRICE
$4,005.7500
11. ERRC
T
12. WEAPON SYSTEM
B-1B/B-52
13. END ITEM APPLICATION
MHU-196/M and MHU-204/M
14. HISTORY
DOES ORGANIC REPAIR OR DMISA REPAIR CAPABILITY CURRENTLY EXIST? X NO YES (if yes, specify SOR)
HAS THE ITEM PREVIOUSLY BEEN CONTRACT REPAIRED?
IF YES, COMPLETE TABLE BELOW FOR LAST 5 YEARS (not to exceed last 3 contracts)
NO X YES
SOURCE NAME CAGE CONTRACT NUMBER AWARD DATE
MOTION INDUSTRIES, INC. 11 JUN 20204N240 FA851720P0008
TEXTRON SYSTEMS CORPORATION 03 MAR 201197384 FA851711M0009
TEXTRON SYSTEMS CORPORATION 28 MAR 200297384 F4160899D0395RJ04
15. PMS SELLER NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART II (To be completed by Equipment Specialist)
16. TECHNICAL ORDERS REQUIRED NO YES (annotate required data and availability on RDL) X UNKNOWN
17. OTHER SPECIFICATIONS / SPECIAL REPAIR CRITERIA REQUIRED NO YES (annotate required data and availability on RDL) X UNKNOWN
18. THE DATA LISTED IN RDL COMPLETED SPECIFIES THE REPAIR REQUIREMENTS OR
X ADDITIONAL DATA IS REQUIRED (Coordinate with the engineer and screening office to determine information required. Document in Block 33)
19. SPECIAL TOOL / SPECIAL TEST EQUIPMENT IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
SPECIAL FACILITIES ARE X NOT REQUIRED REQUIRED
GOVERNMENT FURNISHED MATERIAL IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
20. EQUIPMENT SPECIALIST NAME
Rouse, Timothy
CODE
OE
OFFICE SYMBOL
410 SCMS / GULB
PHONE
478-222-0146
COMPLETION DATE
04 APR 2024
PART III (To be completed by Screening Technician if applicable)
21. REQUESTED ENGINEERING DATA
LISTED AND ANNOTATED ON RDL X NO DATA
22. SCREENING TECHNICIAN REMARKS
23. SCREENING TECHNICIAN NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART IV (To be completed by the Engineer)
24. CRITICAL SAFETY ITEM
X NO YES
25. CAN THIS ITEM BE COMMERCIALLY
OVERHAULED / REPAIRED (FAR Part 12)
NO X YES
26. PRECONTRACT QUALIFICATION
REQUIRED
X NO YES (JQR/QR, SQS, Waiver)
27. RDL REQUIRED FOR
SOLICITATION
X NO YES
28. RMC / RMSC CODE
R1 / Z
29. RMC / RMSC EXPIRATION DATE
07 OCT 2026
30. REASON FOR OTHER THAN G CODE AND ACTION TO REMEDY
Commercial off the shelf
31. APPROVED / POTENTIAL SOURCES
CAGE
CODE DATE APPROVED
Page 1 of 2AFMC FORM 762, 20060201, V1 Version 8Generated by PRPS using Jasper Reports on 30 Jan 2025
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
32. ENGINEER NAME
Nichols, Zakary G
CODE
N/A
OFFICE SYMBOL
410 SCMS / GULB
PHONE
478-327-9552
COMPLETION DATE
12 APR 2024
PART V (Miscellaneous, if needed)
33. REMARKS (Remarks require Functional Responsibility / Name / Office Symbol / Phone)
Page 2 of 2AFMC FORM 762, 20060201, V1 Version 8Generated by PRPS using Jasper Reports on 30 Jan 2025
File details come from the government source that posted it. Updated .