1 CRSAW_REPORT.pdf
PDF 97 KB Posted
- Attached to
- Pump Assemblies
- Solicitation number
- FA851725RRepairofMechanicalTransmissionAssembly
About this file
This is a Contract Repair Screening Analysis Worksheet (AFMC Form 762) for a hydraulic pump (NSN 4320013554464QS, P/N 2520-025) used in a Truck, Lift, Aerial Stores system. The form was initiated on April 11, 2024, with priority code 02.
The analysis indicates an annual repair quantity of 2 units with a latest repair cost of $1,760 per unit and an annual repair budget value of $3,520. The incumbent contractor is Sandra L Collier (CAGE: 67V88) who has held five consecutive contracts for this repair work since 2014, with the most recent award on July 30, 2021 (contract FA851721F0044). The item has no organic repair or DMISA repair capability and is designated as a commercial item that can be overhauled/repaired under FAR Part 12. The engineer indicates it is not a critical safety item, does not require precontract qualification, and has an RMC/RMSC code of R1/Z with an expiration date of September 14, 2028. No special tools, facilities, or government-furnished material are required for the repair work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA851725Q0014 02 061825.pdf | ||
| 25-00011 PWS Final042425.pdf | ||
| Solicitation042425.pdf | ||
| FA851725Q0014.pdf | ||
| FA851725Q0014.pdf | ||
| 2 QAIRQMT_REPORT.pdf | ||
| 3 QAIRQMT_REPORT.pdf | ||
| PWS_JAN2825.pdf | ||
| 3 CRSAW_REPORT.pdf | ||
| 2 CRSAW_REPORT.pdf | ||
| 3 ITMDESC_REPORT.pdf | ||
| 4075111_PKGRQMT_REPORT.pdf | ||
| 1 QAIRQMT_REPORT.pdf | ||
| 4 QAIRQMT_REPORT.pdf | ||
| 4 CRSAW_REPORT.pdf | ||
| 1 ITMDESC_REPORT.pdf | ||
| 2 ITMDESC_REPORT.pdf | ||
| 4 ITMDESC_REPORT.pdf | ||
| 4074969_TRNSPDATA_REPORT.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART I (To be completed by PMS Seller)
1. FORM INITIATION DATE
11 APR 2024
2. FORM PRIORITY
3. NSN
4320013554464QS
4. PART NUMBER
2520-025
5. PART NUMBER CAGE CODE
56529
6. NOUN
PUMP,HYDRAULIC
7. ANNUAL REPAIR
QUANTITY
8. LATEST REPAIR COST
$1,760.0000
9. ANNUAL REPAIR
BUDGET VALUE
$3,520.00
10. FORECAST UNIT
PRICE
$880.0000
11. ERRC
T
12. WEAPON SYSTEM
Truck
13. END ITEM APPLICATION
Truck, Lift, Aerial Stores
14. HISTORY
DOES ORGANIC REPAIR OR DMISA REPAIR CAPABILITY CURRENTLY EXIST? X NO YES (if yes, specify SOR)
HAS THE ITEM PREVIOUSLY BEEN CONTRACT REPAIRED?
IF YES, COMPLETE TABLE BELOW FOR LAST 5 YEARS (not to exceed last 3 contracts)
NO X YES
SOURCE NAME CAGE CONTRACT NUMBER AWARD DATE
SANDRA L COLLIER 30 JUL 202167V88 FA851721F0044
SANDRA L COLLIER 21 NOV 201967V88 FA851720F0007
SANDRA L COLLIER 16 NOV 201867V88 FA851719F0042
SANDRA L COLLIER 08 FEB 201867V88 FA851718F0051
SANDRA L COLLIER 22 APR 201467V88 FA851712D00090005
15. PMS SELLER NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART II (To be completed by Equipment Specialist)
16. TECHNICAL ORDERS REQUIRED NO YES (annotate required data and availability on RDL) X UNKNOWN
17. OTHER SPECIFICATIONS / SPECIAL REPAIR CRITERIA REQUIRED NO YES (annotate required data and availability on RDL) X UNKNOWN
18. THE DATA LISTED IN RDL COMPLETED SPECIFIES THE REPAIR REQUIREMENTS OR
X ADDITIONAL DATA IS REQUIRED (Coordinate with the engineer and screening office to determine information required. Document in Block 33)
19. SPECIAL TOOL / SPECIAL TEST EQUIPMENT IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
SPECIAL FACILITIES ARE X NOT REQUIRED REQUIRED
GOVERNMENT FURNISHED MATERIAL IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
20. EQUIPMENT SPECIALIST NAME
Rouse, Timothy
CODE
OS
OFFICE SYMBOL
410 SCMS / GULB
PHONE
478-222-0146
COMPLETION DATE
11 APR 2024
PART III (To be completed by Screening Technician if applicable)
21. REQUESTED ENGINEERING DATA
LISTED AND ANNOTATED ON RDL X NO DATA
22. SCREENING TECHNICIAN REMARKS
23. SCREENING TECHNICIAN NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
Page 1 of 2AFMC FORM 762, 20060201, V1 Version 15Generated by PRPS using Jasper Reports on 30 Jan 2025
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART IV (To be completed by the Engineer)
24. CRITICAL SAFETY ITEM
X NO YES
25. CAN THIS ITEM BE COMMERCIALLY
OVERHAULED / REPAIRED (FAR Part 12)
NO X YES
26. PRECONTRACT QUALIFICATION
REQUIRED
X NO YES (JQR/QR, SQS, Waiver)
27. RDL REQUIRED FOR
SOLICITATION
X NO YES
28. RMC / RMSC CODE
R1 / Z
29. RMC / RMSC EXPIRATION DATE
14 SEP 2028
30. REASON FOR OTHER THAN G CODE AND ACTION TO REMEDY
Commercial off the shelf
31. APPROVED / POTENTIAL SOURCES
CAGE
CODE DATE APPROVED
32. ENGINEER NAME
Nichols, Zakary G
CODE
N/A
OFFICE SYMBOL
410 SCMS / GULB
PHONE
478-327-9552
COMPLETION DATE
12 APR 2024
PART V (Miscellaneous, if needed)
33. REMARKS (Remarks require Functional Responsibility / Name / Office Symbol / Phone)
Page 2 of 2AFMC FORM 762, 20060201, V1 Version 15Generated by PRPS using Jasper Reports on 30 Jan 2025
File details come from the government source that posted it. Updated .