2.7 - Drawings 7 of 13 - General.pdf

PDF 16 MB Posted

Attached to
Y1DZ--EHRM Training and Administrative Support Space B24 Construction - St Louis, Jefferson Barracks 657-21-703JB
Solicitation number
36C77622B0052
Issued by

About this file

This document provides details for a federal contract solicitation to renovate the first floor of Building 24 at the Jefferson Barracks VAMC in St. Louis, Missouri. The solicitation seeks a general contractor to provide all labor, materials, equipment, supervision, and other items designated in the contract and specifications to complete the EHRM Training and Administrative Support Space construction project in accordance with VA requirements. The contractor shall demolish existing structures, prepare the site for construction, and furnish all testing, labor, and materials to fully renovate the space for training and administrative support for EHRM activation. The solicitation was issued by the VA Technology Acquisition Center Austin under solicitation number 36C77622B0052.

View the file

Other files

File Type Posted
36C77622B0052 0006.pdf PDF
DBA Wage Rates - St Louis County - 09-02-22.pdf PDF
36C77622B0052 0005.pdf PDF
SECTION 08 52 00 - WOOD WINDOWS - HISTORIC REPLACEMENT - REVISED.pdf PDF
36C77622B0052 0004.pdf PDF
36C77622B0052 0003.pdf PDF
Responses to Tech Questions - StL JB TASS - 8-29-22.pdf PDF
36C77622B0052 0002.pdf PDF
Responses to Tech Questions - StL JB TASS - 8-23-22.pdf PDF
SECTION 08 71 00 - DOOR HARDWARE - REVISED.pdf PDF
Site Visit Sign-in Sheet - 08-05-2022.pdf PDF
7 - DBA Wage Rates - St Louis County - 08-05-22.pdf PDF
36C77622B0052 0001.pdf PDF
2.11 - Drawings 11 of 13 - Structural.pdf PDF
6 - Brand Name Justification - St Louis JB.pdf PDF
5 - Limitations on Subcontracting.docx DOCX document
3 - NARA RM Contract Language Clause.pdf PDF
8 - Contractor Safety and Environmental Form.docx DOCX document
1.1 - Specs - Cover_Divisions 00-01.pdf PDF
1.5 - Specs - Divisions 26-28_Divisions 31-33.pdf PDF
2.4 - Drawings 4 of 13 - Electrical.pdf PDF
9 - Site Visit Map - St Louis JB TASS.pdf PDF
2.5 - Drawings 5 of 13 - Fire Alarm.pdf PDF
2.1 - Drawings 1 of 13 - Architectural V1.pdf PDF
2.12 - Drawings 12 of 13 - Survey.pdf PDF
1.8 - Specs Att 3 - SECTION 01 45 35 Statement of SI Tem.xlsx XLSX spreadsheet
1.4 - Specs - Divisions 12-14_Divisions 21-23.pdf PDF
4 - VHA Supp Contract Reqs COVID-19 - 12-14-21.pdf PDF
2.10 - Drawings 10 of 13 - Plumbing.pdf PDF
2.8 - Drawings 8 of 13 - Landscape.pdf PDF
2.6 - Drawings 6 of 13 - Fire Suppression.pdf PDF
2.9 - Drawings 9 of 13 - Mechanical.pdf PDF
2.2 - Drawings 2 of 13 - Architectural V2.pdf PDF
7 - DBA Wage Rates - St Louis County - 07-08-22.pdf PDF
2.13 - Drawings 13 of 13 - Technology.pdf PDF
1.3 - Specs - Divisions 03-10.pdf PDF
1.6 - Specs Att 1 - ENG_FORM_4288-R.pdf PDF
2.3 - Drawings 3 of 13 - Civil.pdf PDF
1.2 - Specs - Division 02.pdf PDF
1.7 - Specs Att 2 - SECTION 01 45 35 Schedule of SI Temp.docx DOCX document
St Louis JB IFB 36C77622B0052 - 7-27-22.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N or th

AREA OF WORK

BLDG 24

AREA OF WORK

BLDG 25

1CC

101T

60G

60T

51T

1CC

1CC

1CC

1G

25T

3 3T

56G

1CC

Plan North

True North

AREA OF WORK

BLDG 25

AREA OF WORK

BLDG 24

CONSTRUCTION

ZONE

CONSTRUCTION

ZONE

CONSTRUCTION

ZONE

CONSTRUCTION

ZONE

CONSTRUCTION

ZONE

CONSTRUCTION

ZONE

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

VETERANS

HEALTH

ADMINISTRATION

D :\R ev it

\2 1.

_A

R C

H _R

_b va nd er pl oe g.

rv t

7/ 7/

:1

1:

P M

00-GI-001A

COVER EHRM TRAINING AND ADMIN

SPACE SUPPORT

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

657-21-703JB

07/07/2022 MJ JWR

100% BID DOCS

VEG 21.21

U.S. DEPARTMENT OF VETERANS AFFAIRS

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

VAMC PROJECT #: 657-21-703JB

EHRM TRAINING AND ADMIN SPACE SUPPORT

RENDERED IMAGE AREA OF WORK

NTS

AREA OF WORK

OCCUPATIONAL SAFETY/HEALTH DATE

INFECTION PREVENTIONIST DATE

GENERAL MAINTENANCE FOREMAN DATE

ENERGY ENGINEER DATE

CONTRACTING OFFICER'S REPRESENTATIVE DATE

CONTRACTING OFFICER DATE

VA SIGNATURE BLOCK

NOTE: CONSTRUCTION ZONES INDICATED ON THIS CAMPUS

PLAN ARE FOR OTHER PROJECTS AND ARE NOT PART OF

THIS EHRM TRAINING AND ADMIN SPACE SUPPORT

PROJECT.

SEE 00-GI-001B FOR SHEET INDEX

0 100% BID DOCS 07/07/2022

405872

M

OSE JS ACOBS

M

O

PE

07/07/2022

00-GI-001B

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

VETERANS

HEALTH

ADMINISTRATION

D :\R ev it

\2 1.

_A

R C

H _R

_c ur tis rid en ou r.

rv t

7/ 7/

:3

6:

P M

00-GI-001B

INDEX EHRM TRAINING AND ADMIN

SPACE SUPPORT

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

657-21-703JB

07/07/2022 MJ JWR

100% BID DOCS

VEG 21.21

24-AE-532 DETAILS

24-AE-601 SCHEDULES - WALL TYPES

24-AE-611 SCHEDULES - DOORS

24-AE-612 DOOR DETAILS

24-AE-621 SCHEDULES - WINDOWS

24-AE-641 SCHEDULES - ROOM STYLE

24-AE-642 SCHEDULES - ROOM FINISHES

24-AE-643 MATERIALS & FINISHES BOARD

24-AE-901 PERSPECTIVE VIEWS

24-AE-902 PERSPECTIVE VIEWS

24-AE-903 PERSPECTIVE VIEWS CLASSROOMS

24-AE-904 PERSPECTIVE VIEWS CLASSROOMS

24-AE-905 PERSPECTIVE VIEWS CORRIDORS

24-AE-906 EXISTING FLOOR PLAN - FLOOR 01

24-AE-907 HISTORIC PRESERVATION INTERIOR ELEVATIONS

FIRE PROTECTION

24-F-001 FIRE ALARM LEGENDS, NOTES, AND SYMBOLS

24-F-002 FIRE SUPPRESSION LEGENDS, NOTES, AND SYMBOLS

24-FD-110 DEMOLITION PLAN - FLOOR 00

24-FD-111 DEMOLITION PLAN - FLOOR 01

24-FD-112 DEMOLITION PLAN - FLOOR 02

24-FD-113 DEMOLITION PLAN - FLOOR 03

24-FD-120 DEMOLITION RCP - FLOOR 00

24-FD-121 DEMOLITION RCP - FLOOR 01

24-FD-122 DEMOLITION RCP - FLOOR 02

24-FD-123 DEMOLITION RCP - FLOOR 03

24-FA-110 FIRE ALARM PLAN - FLOOR 00

24-FA-111 FIRE ALARM PLAN - FLOOR 01

24-FA-112 FIRE ALARM PLAN - FLOOR 02

24-FA-113 FIRE ALARM PLAN - FLOOR 03

24-FX-110 HAZARD PLAN - FLOOR 00

24-FX-111 HAZARD PLAN - FLOOR 01

24-FX-112 HAZARD PLAN - FLOOR 02

24-FX-113 HAZARD PLAN - FLOOR 03

24-FX-120 FIRE SUPPRESSION RCP - FLOOR 00

24-FX-121 FIRE SUPPRESSION RCP - FLOOR 01

24-FX-122 FIRE SUPPRESSION RCP - FLOOR 02

24-FX-123 FIRE SUPPRESSION RCP - FLOOR 03

PLUMBING

24-P-001 PLUMBING ABBREVIATIONS, SYMBOLS, & LEGENDS

24-PQ-601 EQUIPMENT & FIXTURE SCHEDULES

24-PD-110 DEMOLITION PLAN - FLOOR 00

24-PD-111 DEMOLITION PLAN - FLOOR 01

24-PD-112 DEMOLITION PLAN - FLOOR 02

24-PP-110 DOMESTIC WATER PLAN - FLOOR 00

24-PP-111 DOMESTIC WATER PLAN - FLOOR 01

24-PP-113 PLUMBING PIPING PLAN - FLOOR 03

24-PW-110 DRAIN-WASTE-VENT PLAN - FLOOR 00

24-PW-111 DRAIN-WASTE-VENT PLAN - FLOOR 01

MECHANICAL

24-M-001 MECHANICAL ABBREVIATIONS & NOTES

24-M-002 MECHANICAL SYMBOLS

24-MQ-601 EQUIPMENT SCHEDULES

24-MI-601 CONTROL DIAGRAMS

24-MI-602 CONTROLS DIAGRAMS

24-MI-603 CONTROL DIAGRAMS

24-MD-110 DEMOLITION PLAN - FLOOR 00

24-MD-111 DEMOLITION PLAN - FLOOR 01

24-MD-112 DEMOLITION PLAN - FLOOR 02

24-MD-113 DEMOLITION PLAN - FLOOR 03

24-MH-110 HVAC PLAN - FLOOR 00

24-MH-111 HVAC PLAN - FLOOR 01

24-MH-112 HVAC PLAN - FLOOR 02

24-MH-113 HVAC PLAN - FLOOR 03

24-MP-110 PIPING PLAN - FLOOR 00

24-MP-111 PIPING PLAN - FLOOR 01

24-MP-112 PIPING PLAN - FLOOR 02

24-MP-113 PIPING PLAN - FLOOR 03

24-MK-501 TYPICAL DETAILS

24-MK-502 TYPICAL DETAILS

24-MK-503 TYPICAL DETAILS

ELECTRICAL

24-E-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES

24-E-002 ELECTRICAL SYMBOLS

24-ED-110 DEMOLITION PLAN - FLOOR 00

24-ED-111 DEMOLITION PLAN - FLOOR 01

24-ED-112 DEMOLITION PLAN - FLOOR 02

24-ED-113 DEMOLITION PLAN - FLOOR 03

24-ED-601 DEMOLITION ONE-LINE DIAGRAM

24-ED-602 DEMOLITION PANEL SCHEDULES

24-EL-110 LIGHTING RCP - FLOOR 00

24-EL-111 LIGHTING RCP - FLOOR 01

24-EL-112 LIGHTING RCP - FLOOR 02

24-EL-113 LIGHTING RCP - FLOOR 03

24-EL-601 LIGHTING SCHEDULES

24-EP-110 POWER PLAN - FLOOR 00

24-EP-111 POWER PLAN - FLOOR 01

24-EP-112 POWER PLAN - FLOOR 02

24-EP-113 POWER PLAN - FLOOR 03

24-EP-601 EQUIPMENT SCHEDULE

24-EP-602 POWER ONE-LINE DIAGRAM

24-EP-603 ELECTRICAL PANEL SCHEDULES

24-ET-110 TELECOMMUNICATION FLOOR PLAN - FLOOR 00

24-ET-111 TELECOMMUNICATION FLOOR PLAN - FLOOR 01

24-ET-112 TELECOMMUNICATION FLOOR PLAN - FLOOR 02

24-ET-400 TELECOMMUNICATION ENLARGED ROOM DETAILS TR-114B

24-EK-501 TYPICAL DETAILS

24-EK-502 TYPICAL DETAILS

25-ES-101 ELECTRICAL SITE PLAN - PARKING LOT

GENERAL

00-GI-001A COVER

00-GI-001B INDEX

00-GI-002 GENERAL ABBREVIATIONS, NOTES, & SYMBOLS

00-GI-003 ACCESSIBILITY STANDARDS

00-GI-004 CODE DATA

24-GI-110 LIFE SAFETY PLAN - FLOOR 00

24-GI-111 LIFE SAFETY PLAN - FLOOR 01

24-GI-112 LIFE SAFETY PLAN - FLOOR 02

24-GI-113 LIFE SAFETY PLAN - FLOOR 03

24-GI-120 DEPARTMENTAL PLAN - FLOOR 00

24-GI-121 DEPARTMENTAL PLAN - FLOOR 01

24-GI-122 DEPARTMENTAL PLAN - FLOOR 02

24-GC-125 PHASING & ICRA BARRIER PLANS

SURVEY

24-VF-100 TOPOGRAPHIC SURVEY

24-VF-101 IMPROVEMENT AND TOPOGRAPHIC SURVEY

25-VF-100 TOPOGRAPHIC SURVEY

25-VF-101 IMPROVEMENT AND TOPOGRAPHIC SURVEY

CIVIL

00-C-001 CIVIL GENERAL NOTES AND LEGENDS

24-CD-101 CIVIL SITE DEMOLITION PLAN

25-CD-101 CIVIL SITE DEMOLITION PLAN

24-CG-101 CIVIL GRADING PLAN BUILDING 24

24-CG-102 EROSION CONTROL PLAN INITIAL BMPS

24-CG-103 EROSION CONTROL PLAN INTERIM BMPS

24-CG-104 EROSION CONTROL PLAN FINAL STABILIZATION

24-CS-101 CIVIL SITE PLAN BUILDING 24

25-CG-101 CIVIL GRADING PLAN BUILDING 25

25-CG-102 CIVIL EXISTING CONDITIONS DRAINAGE PLAN

25-CG-103 CIVIL DEVELOPED DRAINAGE PLAN

25-CG-104 CIVIL BMP DRAINAGE AREA AMP

25-CG-105 EROSION CONTROL PLAN INITIAL BMPS

25-CG-106 EROSION CONTROL PLAN INTERIM BMPS

25-CG-107 EROSION CONTROL PLAN FINAL STABILIZATION

25-CS-101 CIVIL SITE PLAN BUILDING 25

25-CS-501 CIVIL SITE PLAN DETAILS

25-CS-502 CIVIL SITE PLAN DETAILS

25-CU-101 CIVIL OVERALL UTILITY PLAN

25-CU-301 STORM SEWER PLAN AND PROFILE

25-CU-501 STORM DRAINAGE DETAILS

25-CU-502 STORM DRAINAGE DETAILS

25-CU-503 STORM DRAINAGE DETAILS

XX-CG-501 EROSION CONTROL BMP DETAILS

XX-CG-502 EROSION CONTROL BMP DETAILS

XX-CG-601 COORDINATE POINT SCHEDULE

LANDSCAPE

24-L-001 LANDSCAPE ABBREVIATIONS, NOTES & SYMBOLS

24-LS-101 SITE PLAN

24-LS-401 ENLARGED SITE PLAN

24-LP-101 PLANTING PLAN

24-LP-401 ENLARGED PLANTING PLAN

24-LK-501 LANDSCAPE DETAILS

STRUCTURAL

24-S-001 STRUCTURAL NOTES

24-S-002 STRUCTURAL ABBREVIATIONS, NOTES, & SYMBOLS

24-S-003 STRUCTURAL SPECIAL INSPECTIONS SCHEDULE

24-SB-101A STRUCTURAL FLOOR PLAN - FLOOR SB

24-SB-101B STRUCTURAL FLOOR PLAN - FLOOR 00

24-SB-102 STRUCTURAL FLOOR PLAN - FLOOR 01

24-SB-103 STRUCTURAL FLOOR PLAN - FLOOR 02

24-SB-104 STRUCTURAL FLOOR PLAN - FLOOR 03

24-SB-501 FOUNDATION DETAILS

24-SF-301 FRAMING SECTIONS

24-SF-302 FRAMING SECTIONS

24-SF-303 FRAMING SECTIONS

24-SF-410 ENLARGED FRAMING PLANS

24-SF-411 ENLARGED FRAMING PLANS

24-SF-412 ENLARGED FRAMING PLANS

24-SF-413 ENLARGED FRAMING PLANS

24-SF-510 CMU WALL DETAILS

24-SF-511 CMU WALL DETAILS

24-SF-520 FRAMING DETAILS

24-SF-521 FRAMING DETAILS

24-SF-522 CFMF DETAILS

ARCHITECTURAL

24-AD-110A DEMOLITION PLAN - FLOOR SB

24-AD-110B DEMOLITION PLAN - FLOOR 00

24-AD-111 DEMOLITION PLAN - FLOOR 01

24-AD-112 DEMOLITION PLAN - FLOOR 02

24-AD-113 DEMOLITION PLAN - FLOOR 03

24-AD-120 DEMOLITION RCP - FLOOR 00

24-AD-121 DEMOLITION RCP - FLOOR 01

24-AD-122 DEMOLITION RCP - FLOOR 02

24-AD-131 DEMOLITION PLAN - ROOF

24-AS-101 SITE PLAN

24-AE-110A FLOOR PLAN - FLOOR SB

24-AE-110B FLOOR PLAN - FLOOR 00

24-AE-111 FLOOR PLAN - FLOOR 01

24-AE-112 FLOOR PLAN - FLOOR 02

24-AE-113 FLOOR PLAN - FLOOR 03

24-AE-120 REFLECTED CEILING PLAN - FLOOR 00

24-AE-121 REFLECTED CEILING PLAN - FLOOR 01

24-AE-122 REFLECTED CEILING PLAN - FLOOR 02

24-AE-131 ROOF PLAN

24-AE-132 ROOF PLAN ENLARGED - CANTEEN STORAGE

24-AE-202 ELEVATIONS - EXTERIOR

24-AE-211 ELEVATIONS - INTERIOR

24-AE-212 ELEVATIONS - INTERIOR

24-AE-301 SECTIONS - BUILDING

24-AE-302 SECTIONS - STAIRS ELEVATOR

24-AE-531 DETAILS - ROOF

SHEET INDEX

NTS

PROJECT LOCATION

NTS

CONTRACTOR PARKING & LAYOUT AREA

0 100% BID DOCS 07/07/2022

STAMP:

405872

M

OSE JS ACOBS

M

O

A. ALL CONTRACTORS AND THEIR SUPERVISORY PERSONNEL MUST REVIEW THE GENERAL AND

SUPPLEMENTARY CONDITIONS TO THE CONTRACT.

B. ALL WORK MUST CONFORM WITH APPLICABLE BUILDING CODES, REGULATIONS AND ORDINANCES.

C. CONTRACTOR MUST OBTAIN ALL REQUIRED BUILDING AND OCCUPANCY PERMITS.

D. CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK.

E. CONTRACTOR MUST BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF

CONSTRUCTION AND THE SAFETY OF ALL CONSTRUCTION PERSONNEL, BUILDING OCCUPANTS, AND

VISITORS.

F. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR.

G. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS PERTAINING TO THEIR RESPECTIVE WORK AND REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THAT INSTALLER'S WORK. DO NOT PROCEED UNTIL CONDITIONS ARE SATISFACTORY.

COMMENCING WITH INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR

CONDITIONS.

H. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT VHA COR FOR

CLARIFICATIONS, IF REQUIRED.

I. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE FACE OF GYPSUM WALL BOARD (FOG), FACE OF MASONRY (FOM), FACE OF CONCRETE (FOC) AND COLUMN GRID LINES, UNLESS OTHERWISE NOTED OR

INDICATED.

J. WALL THICKNESSES ARE NOMINAL DIMENSIONS, NOT ACTUAL DIMENSIONS. STUD WALL THICKNESSES ARE

5", UNLESS DIMENSIONED OTHERWISE.

K. MASONRY WALLS ARE 8" THICK (NOMINAL), UNLESS DIMENSIONED OR NOTED OTHERWISE.

L. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION, ITEM, OR DIMENSION IS

REPRESENTATIVE OF, OR THE SAME, FOR SIMILAR CONDITIONS OR INDICATED ITEMS.

M. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN, SECTION, & DETAIL DRAWINGS, AND SO FORTH), CONTACT VHA COR FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION, THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS, AS INDICATED BY THE VHA COR, MUST GOVERN.

N. IF THERE ARE ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT VHA COR FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION: THE MOST EXPENSIVE AND/OR STRICTEST

REQUIREMENTS, AS INDICATED BY THE VHA COR, MUST GOVERN.

O. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS MUST BE REPORTED TO THE VHA

COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE AFFECTED WORK.

P. ANY AND ALL DISCREPANCIES MUST BE REPORTED TO THE VHA COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE AFFECTED WORK. IN THESE INSTANCES, NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE VHA COR'S

WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR MUST REPAIR AND/OR REPLACE ANY

UNAUTHORIZED WORK, AS INDICATED BY THE VHA COR, AT NO ADDITIONAL COST TO THE OWNER (VHA).

Q. ALL DISSIMILAR METAL MATERIALS MUST BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION MATERIAL.

R. ALL EXTERIOR EXPOSED STEEL MUST BE PAINTED.

S. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALL PANELS, AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE, AND SO FORTH, MUST BE SEALED. PROPER SEALANT, FLASHINGS, OR WEATHER-STRIP DESIGNED SPECIFICALLY FOR

THE PURPOSE AND FOR COMPATIBILITY WITH ADJACENT MATERIALS TO PROVIDE A DURABLE

WEATHERTIGHT SEAL TO ELIMINATE AIR LEAKAGE AND WATER ENTRY.

T. PROVIDE SEALANT AND/OR CAULKING BETWEEN DISSIMILAR ADJOINING INTERIOR MATERIALS. (THAT IS

WINDOW SILLS TO GWB, CEILING FINISHES TO MASONRY WALLS, AND SO FORTH.)

U. DOOR OPENINGS NOT LOCATED BY DIMENSION MUST BE CENTERED IN WALL SHOWN OR LOCATED 2" FROM FINISH WALL TO FINISH JAMB, ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE OF THE DOOR TO THE

INTERSECTING WALL UNLESS SPECIFICALLY INDICATED OTHERWISE.

V. CONTRACTOR MUST VERIFY THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES AND THEIR SERVICE

CONNECTIONS WITH THE PROPER UTILITY COMPANY AND/OR UTILITY LOCATE SERVICE.

W. CONTRACTOR MUST COORDINATE SIZE, LOCATIONS AND NUMBER OF ALL ROOF OPENINGS AND ROOF ACCESSORIES WITH ALL OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS.

X. LOCATIONS AND SIZES OF ALL CONCRETE MECHANICAL AND ELECTRICAL PADS MUST BE COORDINATED BY THE MECHANICAL AND ELECTRICAL CONTRACTORS WITH THE SELECTED EQUIPMENT MANUFACTURER AND/OR SUPPLIER. LOCATIONS AND SIZES MUST BE APPROVED BY THE VHA COR PRIOR TO PROCEEDING

WITH THE WORK.

Y. EXCEPT AT FIRE-RATED PARTITIONS, ALL WALL AND COLUMN GYPSUM BOARD FACING MUST BE HELD AT 5/8"

BELOW ROOF STRUCTURE, UNLESS DETAILED OR NOTED OTHERWISE.

Z. AT ALL TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING, BOTTOM TO BE LOCATED AT 4"

AFF VERIFY LENGTHS AND LOCATIONS WITH ELECTRICAL DRAWINGS.

AA. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 1'-6" OF THE FLOOR OR WITHIN 24" OF A DOOR, AND SO FORTH, MUST BE SAFETY GLAZING, APPROVED FOR IMPACT, PER APPLICABLE BUILDING

CODE AND MUST BE PERMANENTLY LABELED BY THE GLAZING MANUFACTURER AS SUCH.

BB. ALL CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM FINISHED FLOOR (HARD SURFACE TILE

FINISH OR FLOOR SUNSTRATE IF CARPETED) TO EXPOSED CEILING FINISH.

CC. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.

DD. ALL CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER MUST HAVE THE SAME FINISHES

AS THE RESPECTIVE ADJOINING SPACE (ROOM, CORRIDOR AND SO FORTH).

EE. CONTRACTOR MUST INSTALL WOOD GROUNDS (BLOCKING AND PLYWOOD) AS REQUIRED FOR THE MOUNTING OF ALL TOILET ACCESSORIES, MILLWORK, CASEWORK, AV EQUIPMENT, MEP ITEMS AND

EQUIPMENT, AND SO FORTH.

FF. ALL PROPRIETARY PRODUCTS DESCRIBED AND/OR DRAWN IN THE DOCUMENTS (BUT NOT SPECIFIED) ARE TO

MEET THE MANUFACTURER'S STANDARD CRITERIA WHICH IS NOT LIMITED TO THE FOLLOWING:

PERFORMANCE REQUIREMENTS, QUALITY ASSURANCE REQUIREMENTS, APPLICABLE CODES AND INDUSTRY STANDARDS, FABRICATION, ASSEMBLY, HANDLING, DELIVERY, STORAGE, INSTALLATION, OPERATION, ADJUSTMENTS, AND SO FORTH. PROVIDE THE MANUFACTURER'S STANDARD WARRANTY AND STANDARD FINISH WARRANTY. PROVIDE PRODUCT DATA, SHOP DRAWINGS, SAMPLES AND MAINTENANCE DATA, AS SPECIFIED. DIVISION 01 SPECIFICATION SECTIONS APPLY, SUCH AS SUBSTITUTION PROCEDURES, SUBMITTAL PROCEDURES, QUALITY REQUIREMENTS, REFERENCES, EXECUTION AND CLOSEOUT PROCEDURES. ANY SUBSTITUTIONS MUST MEET THE DESIGN INTENT, AS WELL AS THE CRITERIA DESCRIBED ABOVE.

GG. REFER TO SPECIFICATIONS FOR ALL REQUIRED TESTING AND INSPECTIONS.

GENERAL NOTES

EARTH /

COMPACT FILL

GRAVEL /

GRANULAR FILL

CONCRETE

SAND / MORTAR /

PLASTER / CUT STONE

BRICK

CONCRETE

MASONRY UNIT

STONE (ELEVATION)

BATT INSULATION

RIGID INSULATION

ACOUSTICAL TILE

(SECTION)

GYPSUM BOARD

COVER BOARD

STEEL / METAL

FINISH WOOD

CONTINUOUS WOOD

BLOCKING / ROUGH

FRAMING

CAST STONE

DISCONTINUOUS

WOOD BLOCKING /

SHIM

PLYWOOD / OSB

MASONRY INSULATION

FIREPROOFING

METAL / WALL PANELS

SPANDREL GLASS

MATERIALS LEGEND

PLASTIC LAMINATE

EXISTING

CONSTRUCTION

ROOM NAME

VIEW TITLE EXAMPLE

ELEVATION CALLOUT EXAMPLE

ENLARGED CALLOUT EXAMPLE

SECTION CALLOUT EXAMPLE

SECTION OR DETAIL SYMBOL IDENTIFIERS

DETAIL NAME

DRAWING NUMBER

DESIGNATOR ON SHEET

DRAWING SEQUENCE

NUMBER INDICATES

WHERE DRAWING IS

LOCATED

TWO CHARACTER

DISCIPLINE DESIGNATOR

AE101

DOOR

NUMBER TAG

WALL

TYPE TAG

WINDOW

TYPE TAG

CENTER LINE

COLUMN

BUBBLE

ROOM TAG

MATCH LINE

DETAIL NUMBER

ON SHEET

SHEET NUMBER

DETAIL NUMBER

ON SHEET

SHEET NUMBER

NEW LINE TYPE

EXISTING LINE TYPE

DEMOLITION LINE TYPE

AREA OF DEMOLITION

VIEW NAME

1/8" = 1'-0"

AE101

AE101

AS101

FLOOR PLAN SYMBOLS LEGEND

AE101

EXTERIOR

INTERIOR

## KEYNOTE

REVISION TAG

DRAWING SCALE

MATERIAL

KEYNOTE

FIXTURE

KEYNOTE

DETAIL NUMBER

ON SHEET

SHEET NUMBER

W3

######-A

######-A

A

A2

1-HR FIRE

2-HR FIRE

3-HR FIRE

4-HR FIRE

1-HR FIRE/SMOKE

2-HR FIRE/SMOKE

3-HR FIRE/SMOKE

4-HR FIRE/SMOKE

0-HR SMOKE

0.5-HR SMOKE

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

VETERANS

HEALTH

ADMINISTRATION

D :\R ev it

\2 1.

_A

R C

H _R

_b va nd er pl oe g.

rv t

7/ 7/

:1

1:

P M

00-GI-002

GENERAL ABBREVIATIONS, NOTES,

& SYMBOLS

EHRM TRAINING AND ADMIN

SPACE SUPPORT

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

657-21-703JB

07/07/2022 MJ JWR

100% BID DOCS

VEG 21.21

S

S SOUTH

SAN SANITARY SEWER

SATC SUSPENDED ACOUSTICAL TILE CEILING

SC SOLID CORE

SCH SCHEDULE

SCRN SCREEN

SECT SECTION

SF SQUARE FOOT (SQFT)

SHT SHEET

SIM SIMILAR

SOG SLAB ON GRADE

SPEC SPECIFICATION (S)

SPKLR SPRINKLE

SPKR SPEAKER

SQ SQUARE

SS STAINLESS STEEL

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURE / STRUCTURAL

SUSP SUSPENDED

SY SQUARE YARD (SQ YD)

SYM SYMMETRICAL / SYMBOL

SYS SYSTEM

T

T TREAD

TEL TELEPHONE

TEMP TEMPORARY / TEMPERED

TG TONGUE & GROOVE

THK THICK (NESS)

THRU THROUGH

TKBD TACK BOARD

TO TOP OF

TOC TOP OF CURB / CONCRETE

TOD TOP OF DECK

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOR TOP OF ROOF

TOS TOP OF STEEL

TOW TOP OF WALL

TPO THERMOPLASTIC POLYOLEFIN

TRANSF TRANSFORMER

TV TELEVISION

TYP TYPICAL

TZ TERRAZZO

U

UH UNIT HEATER

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

V

VA VETERANS ADMINISTRATION

VB VAPOR BARRIER (VPR BR)

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VHA VETERANS HEALTH ADMINISTRATION

VIF VERIFY IN FIELD

VNR VENEER

VTR VENT THROUGH ROOF

VWC VINYL WALLCOVERING

W

W WEST, WIDTH, WIDE

W/ WITH

W/IN WITHIN

W/O WITHOUT

WB WOOD BASE

WC WATER CLOSET

WD WOOD

WDW WINDOW

WH WALL HYDRANT / WATER HEATER

WP WATERPROOFING / WORKING POINT

WR WEATHER RESISTANT

WSF WELDED SEAM SHEET FLOORING

WT WEIGHT

WWF WELDED WIRE FABRIC

X, Y, Z, MISC

& AND

@ AT

XPS EXTRUDED POLYSTYRENE

YD YARD

N

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NSF NET SQUARE FEET

NTS NOT TO SCALE

O

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD / OPPOSITE HAND

OIT OFFICE OF INFORMATION TECHNOLOGY

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

OZ OUNCE

P

PA PUBLIC ADDRESS

PB PUSH BUTTON

PC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PERF PERFORATE (D)

PERM PERMANENT

PERP PERPENDICULAR

PL PLATE / PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLUMB PLUMBING

PLYWD PLYWOOD

PNL PANEL

PNT PAINT

POLY POLYETHYLENE

PR PAIR

PREFAB PREFABRICATE (D)

PREFIN PREFINISHED

PRELIM PRELIMINARY

PREP PREPARE (D)

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PORCELAIN TILE

PTN PARTITION

PVC POLYVINYL CHLORIDE

PVG PAVING

Q

QT QUARRY TILE

QTB QUARRY TILE BASE

QTY QUANTITY

R

R RISER / RADIUS

RA RETURN AIR

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFRIGERATOR

REINF REINFORCE (D), (ING)

REQD REQUIRED

REV REVISED/ REVISION

RFG ROOFING

RH RIGHT HAND

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RR RESTROOM

RSF RESILIENT SHEET FLOORING

RTU ROOF TOP UNIT

H

H HIGH

HB HOSE BIBB

HC HOLLOW CORE

HD HEAD

HDBD HARDBOARD

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HK HOOK

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HS HIGH STRENGTH

HT HEIGHT

HTG HEATING

HTR HEATER

HVAC HEATING / VENTILATING / AIR CONDITIONING

HW HOT WATER

HYD HYDRANT

I

IBC INTERNATIONAL BUILDING CODE

ICRA INFECTION CONTROL RISK ASSESSMENT

ID INSIDE DIAMETER

ILSM INTERIM LIFE SAFETY MEASURES

IN INCH

INCL INCLUDE (D), (ING)

INFO INFORMATION

INST INSTALL / INSTALLATION

INSUL INSULATE / INSULATION

INT INTERIOR

INV INVERT

J

JAN JANITOR

JB JUNCTION BOX

JST JOIST

JT JOINT

K

KIT KITCHEN

KO KNOCKOUT

KPL KICK PLATE

L

L LONG / LENGTH

LAB LABORATORY

LAM LAMINATE (D)

LAV LAVATORY

LBS POUNDS

LF LINEAR FOOT (FEET)

LH LEFT HAND

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LPT LOW POINT

LRG LARGE

LT LIGHT

LTG LIGHTING

LVR LOUVER

LVT LUXURY VINYL TILE

LWC LIGHTWEIGHT CONCRETE

M

MAS MASONRY

MAX MAXIMUM

MBR MEMBER

MDF MEDIUM DENSITY FIBERBOARD

MECH MECHANICAL

MED MEDIUM

MEMB MEMBRANE

MFG MANUFACTURING

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MOD MODULAR

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

D

DBL DOUBLE

DEMO DEMOLISH / DEMOLITION

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DH DOUBLE HUNG

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DMT DEMOUNTABLE

DN DOWN

DR DOOR

DS DOWNSPOUT

DTL DETAIL

DWG DRAWING

E

E EAST

EA EACH

EF EXHAUST FAN

EHRM ELECTRONIC HEALTH RECORDS

MODERNIZATION

EJ EXPANSION JOINT

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EP ELECTRICAL PANELBOARD

EQ EQUAL

EQUIP EQUIPMENT

ESC ESCALATOR

EST ESTIMATE

ETR EXISTING TO REMAIN

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION / EXPOSED

EXT EXTERIOR

F

FA FIRE ALARM

FAB FABRIC

FB FACE BRICK

FBO FURNISHED BY OWNER

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FF&E FIXTURES, FURNITURE & EQUIPMENT

FFE FINISH FLOOR ELEVATION

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIN FINISH / FINISHED

FIXT FIXTURE

FLG FLOORING

FLR FLOOR

FLUOR FLUORESCENT

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOG FACE OF GYPSUM BOARD / WALL

FOM FACE OF MASONRY

FOS FACE OF STUDS

FR FIRE RATED

FRMG FRAMING

FRP FIBER REINFORCED PANEL

FS FLOOR SINK

FT FOOT/ FEET

FTG FOOTING

FUR FURRING

FUT FUTURE

G

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCED CONCRETE

GL GLASS / GLAZING

GOVT GOVERNMENT

GPM GALLON PER MINUTE

GSF GROSS SQUARE FEET

GWB GYPSUM WALL BOARD

GYP GYPSUM

A

ABA ARCHITECTURAL BARRIERS ACT

AC AIR CONDITIONING

ACP ACOUSTICAL CEILING PANEL

ACST ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADJ ADJUSTABLE / ADJACENT

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

AP ACCESS PANEL

APC ARCH PRECAST CONCRETE

APPROX APPROXIMATE

ARCH ARCHITECT / ARCHITECTURAL

ATTEN ATTENUATION

AUTO AUTOMATIC

AV AUDIO / VISUAL

AVG AVERAGE

AWP ACOUSTICAL WALL PANEL

B

BD BOARD

BITUM BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BM BENCH MARK / BEAM

BO BOTTOM OF

BOC BACK OF CURB

BOT BOTTOM

BRG BEARING

BRK BRICK

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BVL BEVELED

C

C COURSE

CAB CABINET

CAP CAPACITY

CB CATCH BASIN

CCTV CLOSED CIRCUIT TV

CF CUBIC FEET

CFM CUBIC FEET PER MINUTE

CG CORNER GUARD

CI CAST IRON

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLOS CLOSET

CLR CLEAR / CLEARANCE

CMP CORRUGATED METAL PIPE

CMT CERAMIC MOSAIC TILE

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

COMB COMBINATION

CONC CONCRETE

CONN CONNECTION / CONNECT

CONST CONSTRUCT / CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S REPRESENTATIVE

CORR CORRIDOR / CORRUGATED

CP CONCRETE PIPE

CPT CARPET

CR CLASSROOM

CS COUNTERSINK

CSMT CASEMENT

CT CERAMIC TILE

CU CUBIC

CW COLD WATER

ARCHITECTURAL ABBREVIATIONS

0 100% BID DOCS 07/07/2022

405872

M

OSE JS ACOBS

M

O

A. ALL DIMENSIONS ARE MEASURED FROM THE FINISH FLOOR AND THE FINISH WALL, UNLESS NOTED OTHERWISE. ACCESSIBILITY GUIDELINES ARE BASED ON “PG-18-13 VA BARRIER FREE DESIGN

STANDARD” AND THE “ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS).”

B. ACCESSIBLE UNOBSTRUCTED REACH RANGES:

1. FORWARD REACH = 15" MIN TO 48" MAX

2. SIDE REACH = 15" MIN TO 48" MAX

C. DOOR HARDWARE (TO CENTER OF HARDWARE):

STANDARD MOUNTING HEIGHTS:

1. PUSH PLATES = 42"

2. PULL HANDLES = 42"

3. KNOBS / LEVERS = 40"

4. PANIC DEVICE = 42" CL OF BAR

5. KICKPLATES:

a. WIDTH = DOOR WIDTH MINUS 2"

b. CENTER HEIGHT = 16" FROM BO DOOR

6. THRESHOLDS:

a. STANDARD = 1/2" MAX

b. EXTERIOR SLIDING DOORS = 3/4" MAX

D. DRINKING FOUNTAINS & ELECTRICAL WATER COOLERS (TO SPOUT):

1. STANDARD = 38" MIN TO 43" MAX

2. ACCESSIBLE = 36" MAX (27" MIN CLEAR KNEE SPACE)

E. COUNTERTOPS (TO SINK RIM / COUNTERTOP):

1. ACCESSIBLE = 28" MIN TO 34" MAX

F. WATER CLOSETS (TO TOP OF SEAT):

1. STANDARD = 14" TO 15"

2. ACCESSIBLE (TO TOP OF SEAT) = 17" TO 19"

3. ACCESSIBLE FLUSH CONTROLS = 44" MAX

G. URINALS (TO RIM):

1. STANDARD = 24" MAX

2. ACCESSIBLE = 17" MAX

3. ACCESSIBLE FLUSH CONTROLS = 44" MAX

H. LAVATORIES (TO SINK RIM / COUNTERTOP):

1. STANDARD = 36" MAX

2. ACCESSIBLE = 34" MAX (29" MIN CLEAR KNEE SPACE)

I. MIRRORS:

1. TO B/O REFLECTIVE SURFACE:

a. STANDARD = VARIES

b. ACCESSIBLE = 40" MAX

2. TO T/O REFLECTIVE SURFACE:

a. STANDARD = VARIES

b. ACCESSIBLE = 74" MIN

J. GRAB BARS - ACCESSIBLE (TO TOP OF BAR):

1. WATER CLOSETS = 33" MIN TO 36" MAX

2. SHOWERS = 33" MIN TO 36" MAX (FROM BO SHOWER)

3. BATHTUBS:

a. TOP BAR = 33" MIN TO 36" MAX

b. BOTTOM BAR = 9" ABOVE TOP OF TUB

K. SHOWER HEADS (FROM FLOOR TO HEAD):

1. STANDARD = 72" TO 84"

2. ACCESSIBLE = SPRAY UNIT WITH HOSE 60" LONG MIN

3. ACCESSIBLE FIXED SHOWER HEAD = 48" AFF

L. SHOWER CONTROLS (TO CONTROL AREA):

1. STANDARD = 48" MAX (TO TOP)

2. ACCESSIBLE = 38" MIN TO 48" MAX

M. SHOWER ROD (FROM FLOOR TO CL): STANDARD = 78" MAX

N. TOILET PARTITIONS:

1. TO BOTTOM = 12"

2. TO TOP = 70"

O. URINAL PARTITIONS:

1. TO BOTTOM = 18"

2. TO TOP = 60"

P. TOILET PAPER DISPENSER (TO CL OF OUTLET):

1. STANDARD = 24"

2. ACCESSIBLE = 15" MIN TO 48" MAX

Q. WALL MOUNTED SOAP DISPENSER (TO CL OF PUSH BUTTON):

1. STANDARD = 40"

2. ACCESSIBLE = VARIES (REFER TO OBSTRUCTED AND UNOBSTRUCTED REACH RANGES)

3. ACCESSIBLE SIDE REACH = 46" MAX ABOVE SINK IN COUNTER

R. PAPER TOWEL DISPENSER / WASTE RECEPTACLE (TO TOWEL SLOT):

1. STANDARD = 40" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN

3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN

S. WARM AIR HAND DRYER (TO PUSH SWITCH):

1. STANDARD = 44" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN

3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN

T. SANITARY NAPKIN DISPENSER (TO CL OF COIN SLOT):

1. STANDARD = 40" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN

3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN

U. SANITARY NAPKIN DISPOSAL (TO TOP OF UNIT):

1. STANDARD = 28" MAX

2. ACCESSIBLE = 19" MIN TO 24" MAX (TO OPENING).

V. TOILET SEAT COVER DISPENSERS (TO OPENING):

1. STANDARD = 40" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN

3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN

W. SHELVES: ACCESSIBLE = 48" MAX

X. COAT HOOKS:

1. STANDARD = 68"

2. ACCESSIBLE = 48" MAX

Y. CHALKBOARDS, TACKBOARDS & MARKERBOARDS:

1. STANDARD = 32" TO 39" (TO BO BOARD OR CHALK TRAY)

2. STANDARD = 80" (RECOMMENDED, TO TOP OF BOARD)

Z. THERMOSTATS & CONTROL DEVICES (TO TOP):

1. ACCESSIBLE FORWARD REACH = 48" MAX

2. ACCESSIBLE SIDE REACH = 48" MAX

AA. LIGHT SWITCHES & CARD READERS (TO CL):

1. LOCATE 6" FROM DOOR JAMB

2. ACCESSIBLE = 48" MAX

BB. CONVENIENCE RECEPTACLES / ELECTRICAL / TELEPHONE / DATA (TO CL):

1. STANDARD = 18"

2. ACCESSIBLE = 15" MIN

CC. EXIT LIGHTS - WALL MOUNTED:

1. 2" BELOW CEILING

2. 2" MIN ABOVE DOOR FRAME EQUAL SPACE FROM CEILING TO TOP OF FRAME

DD. FIRE EXTINGUISHERS (TO TOP UNLESS NOTED OTHERWISE):

1. GROSS WT 40 LBS OR LESS = 60" MAX

2. GROSS WT MORE THAN 40 LBS = 42" MAX

3. ACCESSIBLE = 40" MAX (TO BO CABINET)

EE. FIRE ALARM PULL STATION (TO LEVER):

1. STANDARD = 48" MAX

2. ACCESSIBLE FORWARD REACH = 48" MAX

3. ACCESSIBLE SIDE REACH = 48" MAX

FF. SMOKE AND / OR HEAT DETECTORS:

1. STANDARD = CEILING HEIGHT

GG. HORN / SPEAKER / VISUAL SIGNALS:

1. STANDARD = 80" AFF OR 6" BELOW CEILING - WHICHEVER IS LOWER

HH. ROOM SIGNAGE (TO CL):

1. STANDARD = 60" HIGH AFF & WITHIN 18" OF LATCH SIDE OF DOOR

II. REFER TO SHEET 24-AE-532 FOR WALL REINFORCEMENT DETAILS REQUIRED BETWEEN WALL

FRAMING STUDS FOR MOUNTING GRAB BARS AND OTHER ACCESSORIES TO WALLS.

GENERAL NOTES

CLEAR FLOOR SPACE,

PARALLEL APPROACH HIGH AND LOW SIDE REACH MAXIMUM SIDE REACH OVER OBSTRUCTIONS

M

IN

30" MIN

M A

X

10" TO 24" MAX

M A

X

M A

X

CLEAR FLOOR SPACE, ALCOVE,

FORWARD APPROACH

36" MIN

X

4"

GRAB BAR

T O

P O

F O

P E

N

IN

G

M A

X

DISPENSER

M

IN

1/

2" B

O O

P E

N

IN

G

M

IN

54" MIN

T O

T O

P O

F B

A R

T O

6"

MAX

12" 42" MIN

7" TO 9"

ELEVATION

SIDE WALL

ACCESSIBLE WATER CLOSET

SIDE WALL

GRAB BAR

WATER CLOSET FLUSH

HANDLES SHALL BE

LOCATED ON THE TRANSFER

SIDE OF THE STOOL

24" MIN

18" MAX

16" MIN

DISPENSER

T O

T O

P O

F B

A R

T O

6"

12" MIN

ELEVATION

T O

P O

F S

E A

T

M

IN

T

O

7" M

A

X BACK WALL

ACCESSIBLE WATER CLOSET

BACK WALL

N F

P A

IN

S

T A

LL

P

E R

FIRE EXTINGUISHER

CABINET

N F

P A

IN

S

T A

LL

P

E R

TYPICAL MOUNTING HEIGHTS

FIRE EXTINGUISHER CABINET

FIRE

EXTINGUISHER

& STANDARD

BRACKET

N F

P A

IN

S

T A

LL

P

E R

N F

P A

IN

S

T A

LL

P

E R

TYPICAL MOUNTING HEIGHTS

FIRE EXTINGUISHER

NOSINGS - RADIUS

1/2" MAX

1 1/2" OD HANDRAIL

12" MIN

T O

T O

P O

F H

A N

D R

A

IL

M

IN

T O

4"

M A

X

T O

T O

P O

F H

A N

D R

A

IL

M

IN

T O

4"

M A

X

1 1/2" MAX

TREAD 11" MIN

12" MIN

T O

T O

P O

F H

A N

D R

A

IL

M

IN

T O

4"

M A

X

4" M

IN

T

O

M

A X

VA/ABAAS STANDARDS

1/

2" M

IN

1 1/4" TO 2"

4 1/2" MAX

1 1/2" MIN

4 1/2" MAX

1 1/2" MIN

HANDRAIL CLEARANCE

LIGHT SWITCH

M A

X

4'

MAX

1' - 0"

2"

THERMOSTAT

M

IN

1'

RECEPTACLE

TYPICAL MOUNTING HEIGHTS

DOOR SWITCH

4" TYP

12" MIN

18" MIN

PULL SIDE

PUSH SIDE

X

M

IN

M

IN

24" MIN

24" MIN

PULL SIDE

PUSH SIDE48

M

IN

M

IN

22" MIN

36" MIN

PULL SIDE

PUSH SIDE

M

IN

M

IN

22" MIN

42" MIN

PULL SIDE

PUSH SIDE 48

M

IN

M

IN

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

A P

P R

O A

C H

APPROACH

APPROACH

MANEUVERING CLEARANCES

DOOR PROVIDED W/ CLOSER

DOOR PROVIDED W/ CLOSER

DOOR PROVIDED W/ CLOSER & LATCH

HINGE APPROACH

HINGE APPROACH

HINGE APPROACH

DOOR PROVIDED W/ CLOSER

& LATCH

FRONT APPROACH

X

SANITARY

NAPKIN

DISPOSAL

TOILET PAPER

DISPENSER

1'

M

IN

SOAP DISPENSER

( 4" MAX PROJ)

MIRROR

SANITARY

NAPKIN

DISPENSER

INTEGRAL WASTE

DISPOSAL WHERE

APPLICABLE

( 4" MAX PROJECTION)

TOWEL

DISPENSER

PAPER TOWEL

DISPENSER

(4" MAX PROJECTION)

BABY CHANGING

STATION

PASS-THRU

PAPER TOWEL DISPENSER

(4" MAX PROJECTION)

R E

F

LE

C T

IV

E

S U

R F

A C

E

3'

M A

X T

O B

O

4'

M A

X

4'

M A

X

S E

E N

O T

E

4'

R E

F

LE

C T

IV

E

S U

R F

A C

E

6'

M

IN

T O

T O

P O

F

TYPICAL MOUNTING HEIGHTS

I I. PORTABLE FIRE EXTINGUISHERS

1. PLACEMENT

A. INSTALLATION HEIGHT

1. FIRE EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 LB SHALL BE

INSTALLED SO THE THE TOP OF THE FIRE EXTINGUISHER IS NOT MORE THAN 5 FT

ABOVE THE FLOOR.

2. FIRE EXTINGUISHERS HAVING A GROSS WEIGHT GREATER THAN 40 LB (EXCEPT

WHEELED TYPES) SHALL BE INSTALLED SO THAT THE TOP OF THE FIRE

EXTINGUISHER IS NOT MORE THAN 3 1/2 FT ABOVE THE FLOOR.

3. IN NO CASE SHALL THE CLEARANCE BETWEEN THE BOTTOM OF THE HAND PORTABLE

FIRE EXTINGUISHER AND THE FLOOR BE LESS THAN 4 IN.

CLEAR

FLOOR

SPACE

NOTE: PARTITION DOOR IS

TO BE LOCATED OPPOSITE

OF WC LOCATION

5' - 6" CLEAR

6'

C

LE

A R

ACCESSIBLE WATER CLOSET

APPROACH

A P

P R

O A

C H

LAVATORIES

5' - 7" MIN

CLEAR

FLOOR SPACE

(36" CLEAR IN

FORWARD

APPROACH

ALCOVE)

M A

X

M A

X

M A

X

M A

X

PLAN

30" MIN

M

IN

ELEVATIONS

/2

M

IN

ACCESSIBLE URINAL

CLEAR

FLOOR

SPACE

9" M

IN

M

IN

25" MAX

17" MIN

M A

X

30" MIN

M

IN

M A

X

PLAN

KNEE CLEARANCE

MEASURED TO

THE HIGHER OF

COUNTER OR SINK

11" MIN6" MAX

8" MIN

SECTION

ACCESSIBLE LAVATORY AT COUNTER

M

IN

PLAN

60" MIN

X

5"

M A

X

M

IN

15" MIN

30"x 48" MIN

CLEAR ACCESS

SPACE

ACCESSIBLE

FOUNTAIN

STANDARD

FOUNTAIN

DUAL ACCESSIBLE DRINKING

FOUNTAIN FORWARD

APPROACH

SPOUT SHALL BE WITHIN

5" OF FRONT AND SHALL

DIRECT FLOW PARALLEL

TO FRONT. FLOW SHALL

BE A MIN OF 4" HIGH.

M A

X

M

IN

9" M

IN

6" MAX

8" MIN

5" MAX

15" MIN

SECTION

ACCESSIBLE DRINKING

FOUNTAIN SECTION

ACCESSIBLE

FOUNTAIN

STANDARD

FOUNTAIN

ELEVATION

T O

S P

O U

T

M A

X

C

LE

A R

M

IN

T O

S P

O U

T

M

IN

T O

3"

M A

X

DUAL ACCESSIBLE DRINKING

FOUNTAIN

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

VETERANS

HEALTH

ADMINISTRATION

D :\R ev it

\2 1.

_A

R C

H _R

_b va nd er pl oe g.

rv t

7/ 7/

:1

1:

P M

00-GI-003

ACCESSIBILITY STANDARDS EHRM TRAINING AND ADMIN

SPACE SUPPORT

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

657-21-703JB

07/07/2022 MJ JWR

100% BID DOCS

VEG 21.21

GENERAL NOTES (CONT.)

0 100% BID DOCS 07/07/2022

405872

M

OSE JS ACOBS

M

O

PE

07/07/2022

Issue Date

07/07/2022

Issue Date

07/07/2022

Issue Date

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

VETERANS

HEALTH

ADMINISTRATION

C :\U se rs

\V .B

.S .1

\D oc um en ts \2

1.

_A R

C H

_R

_j ra th 3W

JH

G

.r vt

5/

/2

:2 4:

A

M

00-GI-004

CODE DATA EHRM TRAINING AND ADMIN

SPACE SUPPORT

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

657-21-703JB

05/12/2022 MJ TW

100% BID DOCS

VEG 21.21

Notice to Proceed = 05.06.21

ASME Code for Pressure Piping

ASME A17.1 Safety Code for Elevators and Escalators, American Society of Mechanical Engineers (2019)

VB

V (000)

0-Hrs

0-Hrs

0-Hrs

0-Hrs

0-Hrs

0-Hrs

Not Applicable

Not Applicable

Fully

0-Hrs

1-Hr (Connecting 3 or Less Stories)

NA

NA

1-Hr (Connecting 3 or Less Stories)

1-Hr (Connecting 3 or Less Stories)

NA

Sprinklered

Required/Provided based on New Assembly

Class B

Class B

Class C

Class I or Class II

PG-18-4 VA Standard Details

PG-18-5 Equipment Guide List (12.2019)

H-18-8 Seismic Design Requirements (05.01.20)

PG-18-9 Space Planning Criteria (02.21.21)

Architectural Design Manual (08.01.14)

Electrical Design Manual (12.01.19)

Renovation (2021)

VA DESIGN MANUALS (DM)

VA Fire Protection Design Manual (8th Edition - 06.01.21)

VA PROGRAM GUIDES (PG-#-#)

PG-18-1 VA Master Specifications

PG-18-3 Design & Construction Procedure (07.01.21)

PG-18-13 VA BIM & CAD Standards (02.2017)

PG-18-14 Room Finishes, Door, & Hardware Schedule (04.10.17)

PG-18-15 A/E Design Submission Requirements (Volume C - Minor and NRM Projects)

PG-18-17 Environmental Planning Guidance - NEPA Interim Guidance ‐ Projects (09.30.10)

VA DESIGN GUIDES (DG)

PG-18-9: Space Planning Criteria - Office of Information and Technology (OIT) - Chapter 232 (02.01.11)

Lighting Design Manual (12.01.15)

HVAC Design Manual (11.01.17)

Interior Design Manual (11.01.20)

Physical Security and Resiliency Design Manual (09.01.21)

Plumbing Design Manual (05.01.21)

VA Signage Design Guide (09.01.21)

PG-18-12 Office of Information and Technology Design Guide (02.2011)

PG-18-10 Telecommunications and Special Telecom Systems Design Manual (02.2016)

NFPA 13 Standard for the Installation of Sprinkler Systems - 2019

NFPA 54, National Fuel Gas Code, 2021

NFPA 72, National Fire Alarm and Signaling Code - 2019

NFPA 80, Standard for Fire Doors and Other Opening Protectives - 2019

NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2021

NFPA 90B, Standard for the Installation of Warm Air Heating and Air-Conditioning Systems, 2021

National Fire Protection Association (NFPA)

NFPA National Fire Codes (Exceptions : NFPA 5000 and NFPA 900)

NFPA 101 Life Safety Code - 2021 (LSC)

Referenced Publications (Applicable but not all inclusive)

NFPA 1 Fire Code - 2021

NFPA 10 Standard for Portable Fire Extinguishers - 2018

Architectural Barriers Act Accessibility Standards (ABAAS) 2015

ASHRAE

ASHRAE Standard 15 Safety Code for Mechanical Refrigeration

ASHRAE Standard 34 Designation and Safety Classification of Refrigerants

ASHRAE Standard 90.1

NFPA 70 National Electrical Code - 2020 (NEC)

International Code Council (ICC)

International Building Code - 2021 (IBC)

International Plumbing Code - 2021 (IPC)

Accessibility

PG-18-13 VA Sustainable Design Manual (01.01.17, revised 11.01.18)

Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings (AISC)

PROJECT SCOPE

ASME

ASME Boiler and Pressure Vessel Code

Miscellaneous

Occupational, Safety and Health Administration (OSHA) Standards

Building Code Requirements for Reinforced Concrete, ACI and Commentary (ACI 318)

Addition to Existing (AD)

Modification (MD)

IBC

Addition to Existing (AD)

Renovation to Existing

Alteration Level 3 (A3)

Change of Occupancy (CO)

LSC

Change of Use (CU)

Change of Occupancy Classification (CO)

B U

IL

D

IN

G

P L

A N

N

IN

G

USE AND OCCUPANCY CLASSIFICATION

Existing Building (2021) - Story 02

Occupancy(s) - Main

Accessory Occupancies

A D

M

IN

IS

T

R A

T

IO

N

PROJECT INFORMATION

Owner / Tenant

VA ST. LOUIS HEALTH CARE SYSTEM - JEFFERSON BARRACKS DIVISION

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

Project / Building

EHRM TRAINING AND ADMINISTRATION SPACE SUPPORT (21.21)

BUILDING 24

REGULATORY

Existing Building (1936)

See "OCCUPANCY CLASSIFICATION" Matrix

See "OCCUPANCY CLASSIFICATION" Matrix

See "DESIGN NARRATIVE"

Number of Stories

Non-Separated (Mixed)

BUILDING DATA

Building Area

Building Height

Floor Construction & Secondary Members

Roof Construction & Secondary Members

(X) Notes

Fire Separation Distance (FSD)

F

IR

E P

R O

T E

C T

IO

N

CONSTRUCTION CLASSIFICATION

Construction Classification (IBC)

Construction Classification (LSC)

Building Elements FRR (Hours)

Primary Structural Frame

Bearing Walls - Interior

Nonbearing Walls - Interior

Projections

FIRE PROTECTION SYSTEMS

Automatic Sprinkler System

FIRE-RESISTANCE RATINGS (FRR)

Corridors

Elevator Hoistways

Shafts (Mechanical)

Special Rooms or Spaces

Corridor Enclosure FRR (Hours)

Interior Exit Stairway (IES)

Occupancy Separations

Control Areas (Hazardous Materials)

Vertical Openings (VO)

Corridors and Exit Access Stairway Enclosures

Rooms and Enclosed Spaces

Interior Floor Finish and Floor Covering

INTERIOR FINISHES

Wall and Ceiling Finishes

Interior Wall and Ceiling Finish Materials

Interior Exit Stairways & Ramps

Type of Construction (IBC)

Type of Construction (LSC)

Automatic Sprinkler System (ASPS)

A# (SF) % A# (SF) % A# (SF) %

Assembly

A-2 (Restaurants) • 4311 43.9% 0.0% 0.0% 18,000 2 Y N

A-3 (Conference Rooms) • 0 0.0% 1104 14.0% 0.0% 18,000 2 N Y

Business (B) • 2014 20.5% 6784 86.0% 4351 100.0% 27,000 3 N Y Y N Y N

Factory and Industrial

F-1 (Moderate Hazard) • 550 5.6% 0.0% 0.0% 25,500 2 N N

Mercantile (M) • 1740 17.7% 0.0% 0.0% 27,000 2 N Y

Storage

S-1 (Moderate Hazard) • 1194 12.2% 0.0% 0.0% 27,000 2 N Y

9809 100.0% 7888 100.0% 4351 100.0%

Assembly (New/Existing) - Ch 12/13

< 300 • 2

Business (New/Existing) - Ch 38/39 • NA

Industrial - Ch 40

General Purpose • NA

Mercantile (New/Existing) - Ch 37/38

Regular • NA

Storage - Ch 42

Low & Ordinary Hazard • NA

EHRM TRAINING AND ADMIN SPACE SUPPORT (21.21)

OCCUPANCY CLASSIFICATIONS : STORY(S) 00, 01, & 02VB

V (000)

Y

Use and Occupancy Classification

IB

C

C h

L S

C

C h

ACTUALS (Story 00) ACTUALS (Story 01) Story 01 Compliant? Story 02 Compliant?

AREA

S to rie s

AREA

S to rie s

AREA

S to rie s

ACTUALS (Story 02)

H ei gh t (

F ee t)

C om pl ia nt

H ei gh t

ALLOWABLES Story 00 Compliant?

A re a (S

F

S to rie s

H ei gh t (

F ee t)

P re do m in an t

A cc es so ry

S ep ar at ed

N on

-S ep ar at ed

A re a (S

F

A ll S to rie s

S to rie s

1 2 3 53 Y

A cc es so ry

S ep ar at ed

N on

-S ep ar at ed

A re a (S

F

A ll S to rie s

S to rie s

P re do m in an t

A cc es so ry

S ep ar at ed

N on

-S ep ar at ed

A re a (S

F

A ll S to rie s

S to rie s

P re do m in an t

Y

TOTALS : Areas + Percentages Y

Y Y

N Y

Y60

N Y

Y Y

N

1 2 3 Y Y Y

0.3

0.2

A Stair 0.3 44 44 / 0.30 146 44 44 / 0.30 146 44 44 / 0.30 146 44 44 / 0.30 146

B Door (into Stairway) 0.2 36 33.5 / 0.20 = 167 36 33.5 / 0.20 = 167 36 33.5 / 0.20 = 167 36 33.5 / 0.20 = 167

C Door (into Stairway) 0.2 36 33.5 / 0.20 = 167 36 33.5 / 0.20 = 167

D EP Door (Exit Discharge) 0.2 36 33.5 / 0.20 = 167

E Door (Exit Discharge) 0.2 36 33.5 / 0.20 = 167

A Stair 0.3 60 60 / 0.30 200 60 60 / 0.30 200 60 60 / 0.30 200

B Door (into Stairway) 0.2 42 39.5 / 0.20 = 197 42 39.5 / 0.20 = 197 42 39.5 / 0.20 = 197

C Door (Exit Discharge) 0.2 42 39.5 / 0.20 = 197

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

A Door (to Stairway) 0.2 36 33.5 / 0.20 = 167

B Door (Exit Discharge) 0.2 69 69 / 0.20 = 345

Exit Exit Stairway (EES-Story.4) EES-00.4

Exit Discharge C (ED-Story.C)

ED-00.B

Exit Exit Stairway (EES-Story.3)

ED-00.C

EES-00.2

343 343 146

Occ Load Demand (Calculated) 233 211 24 3

1,512Occ Load Capacity (Calculated)

EES-00.3

Exit Discharge A (ED-Story.A) ED-00.A

Exit Discharge B (ED-Story.B)

Interior Exit Stairway #1 (IES-Story.1)

146 146 146

Interior Exit Stairway C (IES-Story.2)

197 197 197

IES-00.1 IES-01.1 IES-02.1

Exit Exit Stairway (EES-Story-1)

Exit Exit Stairway (EES-Story.2)

EES-00.1

IES-00.2 IES-01.2 IES-02.2

S iz e (I n

C lr

W id th

In

M u lt ip lie r

O cc u p an ts

L o w es t O

L

IES-03.1

L o w es t O

L

M u lt ip lie r

C lr

W id th

In

M u lt ip lie r

O cc u p an ts

L o w es t O

L

S iz e (I n

C lr

W id th

In

EHRM TRAINING AND ADMIN SPACE SUPPORT (21.21)

Exit Components

M u lt ip lie r

Story 00 Story 01 Story 02 Penthouse

S iz e (I n

C lr

W id th

In

O cc u p an ts

M u lt ip lie r

O cc u p an ts

L o w es t O

L

S iz e (I n

Stair Multiplier

Door Multiplier

OL

Assembly (Restaurants, Banquet Rooms, & Food Courts) A-2b 131 66 0.9 0.9 0.3 0.3 0.3

Assembly (Auditoriums, Lecture Halls & Libraries) A-3a 195 98 0.8 1.5 0.5 0.5 0.4

Business B 80 40 1.6 1.6 1.0 1.0 0.8

Mercantile M 55 28 0.1 0.1 0.0 0.0 0.1

Storage S-1/2 10 5 0.1 0.1 0.1 0.1 0.0

471 237

3.4 4.1 1.9 1.9 1.5

4 5 2 2 2

3 3 2 2

2 2 2 2

TOTALS (Required) : WCs + LAVs + DFs

EHRM TRAINING AND ADMIN SPACE SUPPORT (21.21)

Classification (Description)

Plumbing Fixtures (IBC Table 2902.1)

STORIES 01-03

T O

T A

L O

L

WC Lav

DF

(M)(F) (M) (F) (M) (F)

TOTALS : Areas, Occupant Loads & Egress Widths

TOTALS : WCs + LAVs + DFs

TOTALS (Provided) : UNISEX

TOTALS (Provided) : WCs + LAVs + DFs

0 0

2TOTALS (Provided) : WCs + LAVs + DFs

OL OL OL OL

ACCESSORY

MECHANICAL 0 sf ● ● F-1/2 887 sf 0 515 sf 0 403 sf 0 1,168 sf 0 2,973 sf 12.6% 0 0.0% 0

STORAGE 300 sf ● ● S-1/2 1,615 sf 6 79 sf 1 835 sf 3 0 sf 0 2,529 sf 10.7% 10 2.1% 10

ASSEMBLY W/O FIXED SEATS

ASSEMBLY - UNCONCENTRATED (CHAIRS & TABLES)

RESTAURANTS 15 sf ● ● A-2b 1,958 sf 131 0 sf 0 0 sf 0 0 sf 0 1,958 sf 8.3% 131 27.8% 131

AUDITORIUMS 15 sf ● ● A-3a 0 sf 0 2,789 sf 186 0 sf 0 0 sf 0 2,789 sf 11.8% 186 39.5% 186

ASSEMBLY - STANDING SPACES

ELEVATOR CAB 5 sf ● ● A-3a 42 sf 9 0 sf 0 0 sf 0 0 sf 0 42 sf 0.2% 9 1.9% 9

BUSINESS USE 150 sf ● ● ● B 1,592 sf 11 3,520 sf 24 3,113 sf 21 318 sf 3 8,543 sf 36.2% 59 12.5% 59

KITCHENS 100 sf ● ● B 2,087 sf 21 0 sf 0 0 sf 0 0 sf 0 2,087 sf 8.8% 21 4.5% 21

MERCANTILE

BASEMENT & GRADE FLOOR AREAS 30 sf ● ● ● M 1,639 sf 55 0 sf 0 0 sf 0 0 sf 0 1,639 sf 6.9% 55 11.7% 55

NON-NET FLOOR AREA 38 sf 985 sf 0 sf 0 sf 1,023 sf 4.3%

9,858 sf 233 7,888 sf 211 4,351 sf 24 1,486 sf 3 23,583 sf 100% 471 100% 471

42 37 181 495 50

DT

TOTALS : Gross Floor Area (GFA) & Occupant Loads (OL)

AVERAGE OL FACTOR

Total Area

BT% CT%

Total

OL

A re a/ O cc

G ro ss

Area Area Area Area

FUNCTION OF SPACE

Total Occupant Load (MOE)

EHRM TRAINING AND ADMIN SPACE SUPPORT (21.21) STORY 00 STORY 01 STORY 02 PENTHOUSE TOTALS

Total

OL

(PF)

NFPA 101 LSC (2021) Table 7.3.1.2 Occupant Load Calc Occupant Load Calc Occupant Load Calc Occupant Load Calc

C2 B3 C3

C la ss ifi ca tio n

N et

IB

C BT CT

L S

CA B0 C0 B1 C1 B2

Mech (0)

Storage (300)

Assembly T&C (15)

Business Areas (150)

Non-Net (0)

Business Areas (50)

Assembly Stand (5)

Merc @ Gr (30)

Kitchen Comm (200)

F5 OCCUPANT LOAD PLANS - STORIES 00, 01, & 02, & PENTHOUSE

NO SCALE F9 OCCUPANCY CLASSIFICATIONS PLANS - STORIES 00 & 01

NO SCALE

E1 OCCUPANCY CLASSIFICATIONS MATRIX - STORIES 00, 01, & 02

NO SCALE

B3 MEANS OF EGRESS CAPACITY

NO SCALE

C3 PLUMBING FIXTURE CALCULATION

NO SCALE

F1 OCCUPANT LOAD MATRIX - STORIES 00, 01, 02 & PENTHOUSE

NO SCALE

See "OCCUPANT LOAD MATRIX"

See "PLUMBING FIXTURE MATRIX"

Yes

Yes - Corridors, Interior Exit Stairways, Public

Restrooms (>300 SF)

0.3 inches / occupant

0.2 inches / occupant

250 Feet New Assembly (Story

300 Feet New/Existing Business

75 Feet New Assembly

100 Feet New/Existing Business

20 Feet New Assembly

50 Feet

44 Inches (LSC)

60 Inches (VA Barrier Free Design Standard)

96 Inches - Not Applicable

24 Inches

72 Inches - Not Applicable

32 Inches

41.5 Inches - Bed Movement : Not Applicable

No

No

Yes

44 Inches (Minimum)

36”

44"

Yes

Not Applicable

Not Applicable

See "MEANS OF EGRESS - CAPACITY"

Yes - Stories 00, 01, & 02

Yes - Stories 00 & 01

Yes

Yes

Yes

Yes

Yes

See "MEANS OF EGRESS - CAPACITY"

See "MEANS OF EGRESS - CAPACITY"

O C

C U

P A

N T

N E

E D

S OCCUPANT LOAD (OL)

PLUMBING FIXTURES (PF)

M E

A N

S O

F E

G R

E S

S

GENERAL MEANS OF EGRESS

Means of Egress - Illumination

Power Source - Normal

Power Source - Emergency Electrical System

Occupant Multiplier Factor (Inches/Occupant)

Dead-End Corridors (DEC)

N/E Assembly & Groups A-2 & A-3

N/E Business & Group B

Corridor Requirements

Corridor Width (Inches)

Stairways

Other Means of Egress (Doors, Corridors, Aisles, Ramps)

EXIT ACCESS

Travel Distance Requirements

Exit Access Travel Distance (EATD)

Common Path of Egress Travel Distance (CPOETD)

Stretcher - Outpatient Medical

Other Means of Egress

Corridor Width - Minimum Clear

Bed Movement - Health Care

MEP Equipment Access

Electrically Locked Egress Doors?

Special Doors

Door Requirements

Door - Clear Width (Minimum)

Hardware

Stairway Requirements

Stairway Width (Inches)

Stairway Width - Minimum Clear

Occupant Load < 50 Occupants

Power-Operated Doors?

Security Grilles?

Ramp Requirements

Occupant Load > 50 Occupants

Stairway Vertical Rise between Landings <12 Feet

Specialty Stairways

Number of Means of Egress

OL = 1 - 500 Occupants = (2) Exits or Exit Access

Maximum OL of Space (Sprinklered)

(2) Means of Egress - Minimum

Maximum OL of Story

Accessible Means of Egress (2 per Story)

Accessible Means of Egress Components

Accessible Route (AR)

OL > (50) occupants (Groups A, B, E, F, M, U)

Two-Way Communication (AoR or EAAR)

EXITS

Number of Exits

Elevators

Exit Access Stairways (IES)

EXIT DISCHARGE

Number of Exit Discharges

OTHER MEANS OF EGRESS

UP

DN DN

UP

DN

S101

STAIR 1

G01C

HOISTWAY

G02A

TELECOM

G03A

STORAGE

G01C

EXT VESTIBULE

G01

CANTEEN

DINING

AREAG01A

FOOD

SERVICE

G09

FOOD

PREP

G01B

ELEV

LOBBY

G07

KITCHEN

G06

KITCHEN

STORAGE

G05

FOOD

PREP

G05A

FOOD

PREP

G10

CANTEEN /

STORAGE

G10A

STORAGE

G15

MECHANICAL

RM

H001

CORRIDOR

G03

CANTEEN

STORE

G11A

OFFICE

G11

OFFICE

G08

HAC

G12

TOILET

FEMALE

G13

TOILET

MALE

Mech (0) 65 sf

Storage (300) 906 sf

Assembly Stand (5) 42 sf

9 Occupants

GFA

9,858 sf Mech (0)

208 sf

Storage (300) 279 sf

Merc @ Gr (30) 1,639 sf

55 Occupants

Assembly T&C (15) 1,958 sf

131 Occupants

Non-Net (0) 38 sf

Kitchen Comm (200) 2,087 sf

Mech (0) 614 sf

Storage (300) 161 sf

Storage (300) 233 sf

1 Occupant

Storage (300) 36 sf

S101

STAIR 1

G01C

HOISTWAY

ATTIC

GSF

1,486 sf

Mech (0) 1,168 sf

DN

UP

UP

UP

CORRIDOR

G01C

HOISTWAY

OFFICE

RESTROOM

OFFICE

STORAGE

S101

STAIR 1

S201

STAIR 2

OFFICE

OFFICE

205A

TELECOM

CORRIDOR

ELEV LOBBY

218A

PASSAGE

STORAGE

216A

STORAGE

201B

CORRIDOR

201A

OFFICE

CLOS

X200

MECH CHASE

Mech (0) 208 sf

Mech (0) 111 sf

Mech (0) 84 sf

Storage (300) 440 sf

Storage (300) 342 sf

Storage (300) 30 sf

Storage (300) 23 sf

GFA

4,351 sf

DN

UP

DN

DN

CR-2

CR-3

CR-5

CR-4

103A

CORRIDOR

CORRIDOR

103B

CORRIDOR

JAN

MEN

WOMEN

102A

LOD TRAINING

OFFICE

LOD OFFICE

114B

TELECOM

MECH

ELEV LOBBY

VESTS201

STAIR 2

STORAGE

107A

STORAGE

107B

STORAGE

104B

LOD PHOTO

S101

STAIR 1

G01C

HOISTWAY

CR-1

PHOTO STUDIO

H002

CORRIDOR

STORAGE

ROOF

Assembly T&C (15) 517 sf

35 Occupants

Assembly T&C (15) 563 sf

38 Occupants

Non-Net (0) 535 sf

Assembly T&C (15) 329 sf

23 Occupants

Assembly T&C (15) 541 sf

39 Occupants

Storage (300) 46 sf

Non-Net (0) 434 sf

Mech (0) 208 sf

Mech (0) 234 sf

Assembly T&C (15) 313 sf

22 Occupants Assembly T&C (15)

526 sf

39 Occupants

Non-Net (0) 16 sf

GFA

7,888 sf

Storage (300) 33 sf

Mech (0) 73 sf

UP

DN DN

UP

DN

S101

STAIR 1

G01C

HOISTWAY

G02A

TELECOM

G03A

STORAGE

G01C

EXT VESTIBULE

G01

CANTEEN

DINING

AREAG01A

FOOD

SERVICE

G09

FOOD

PREP

G01B

ELEV

LOBBY

G07

KITCHEN

G06

KITCHEN

STORAGE

G05

FOOD

PREP

G05A

FOOD

PREP

G10

CANTEEN /

STORAGE

G10A

STORAGE

G15

MECHANICAL

RM

H001

CORRIDOR

G03

CANTEEN

STORE

G11A

OFFICE

G11

OFFICE

G08

HAC

G12

TOILET

FEMALE

G13

TOILET

MALE

Storage & Group S-1 1,194 sf

Existing Business (EB) & Group B 610 sf

Exist Mercantile (EM) & Group M 1,740 sf

Exist Assembly (EA) & Group A-2 4,311 sf

Industrial & Group F-1 590 sf

Existing Business (EB) & Group B 195 sf

Existing Business (EB) & Group B 1,204 sf

DN

UP

DN

DN

CR-2

CR-3

CR-5

CR-4

103A

CORRIDOR

CORRIDOR

103B

CORRIDOR

JAN

MEN

WOMEN

102A

LOD TRAINING

OFFICE

LOD OFFICE

114B

TELECOM

MECH

ELEV LOBBY

VESTS201

STAIR 2

STORAGE

107A

STORAGE

107B

STORAGE

104B

LOD PHOTO

S101

STAIR 1

G01C

HOISTWAY

CR-1

PHOTO STUDIO

H002

CORRIDOR

STORAGE

ROOF

New/Existing Business (NEB) & Group B Business

New Assembly (NE) & Group A-3 1,105 sf

405872

M

OSE JS ACOBS

05/12/2022

405872

M

OSE JS ACOBS

M

O

P 07/07/2022

Issue Date

07/07/2022

Issue Date

0 100% BID DOCS 07/07/2022

UP

DN DN

UP

DN

S101

STAIR 1

G01D

HOISTWAY

G02A

TELECOM

G03A

STORAGE

G01C

EXT VESTIBULE

G01

CANTEEN

DINING

AREAG01A

FOOD

SERVICE

G09

FOOD

PREP

G01B

ELEV

LOBBY

G07

KITCHEN

G06

KITCHEN

STORAGE

G05

FOOD

PREP

G05A

FOOD

PREP

G10

CANTEEN /

STORAGE

G10A

STORAGE

G15

MECHANICAL

RM

H001

CORRIDOR

G03

CANTEEN

STORE

G11A

OFFICE

G11

OFFICE

G08

HAC

G12

TOILET

FEMALE

G13

TOILET

MALE

Drawing Title

VA FORM 08 - 6231

F

CONSULTANTS:

750 W HAMPDEN AVE

SUITE 300

ENGLEWOOD, CO 80110

(720) 550-6307 WWW.VALHALLAENGINEERING.COMDate:Revisions:

10987654321

10987654321

E

D

C

B

A

F

E

D

C

B

A

ARCHITECT/ENGINEERS: STAMP:

Approved: Project Director

Phase Project Title

Location

Issue Date Checked Drawn

Project Number

Drawing Number

Building Number

Number:

VETERANS

HEALTH

ADMINISTRATION

C :\U se rs

\V .B

.S .1

\D oc um en ts \2

1.

_A R

C H

_R

_j ra th 3W

JH

G

.r vt

5/

/2

:2 4:

A

M

24-GI-110

LIFE SAFETY PLAN - FLOOR 00 EHRM TRAINING AND ADMIN

SPACE SUPPORT

1 JEFFERSON BARRACKS DR ST. LOUIS, MO 63125

657-21-703JB

05/12/2022 MJ TW

100% BID DOCS

VEG 21.21

24'12'6'3'1'-6"0'

Plan North

True North

3/16" = 1'-0"

LIFE SAFETY PLAN - FLOOR 00

LOBBY

EP-00.01

EES-00.1

ED

IES-00.01

E D

E D

E X

EX

E X

E D

EES-00.2

EES-00-1

EES-00-2

ED-00.A

ED-00.B

EES-00.3

E D

EX

EES-00.4

EDEES-00-4

E A

E X

1F B

1F B

1F B

1F B

1F B

1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB

1F B

1F B

1F B

1F B

1F B

1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB 1FB

1F B

1F B

1F B

1F B

1F B

1F B

1FB1FB1FB1FB1FB1FB1FB1FB1FB1FB1FB

EX

1SE

1SE

1SE

1SE

1SE

1SE 1SE 1SE 1SE 1SE 1SE

1S E

1S E

1S E

1S E

1S E

HAZ

HAZ

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

1E W

ED

EXISTING EXIT DISCHARGE

EX

0S P

0S P

0S P

0S P

0S P

0S P

0S P

0S P

0S P

0S P

0S P

0SP 0SP 0SP 0SP

0S P

0S P

0S P

0SP 0SP 0SP

0S P

0S P

0S P

0S P

0S P

0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP0SP

LEGEND - LIFE…

This is the start of the file's text. The full file is on GovTribe.