2 - Building Maps.pdf
PDF 5 MB Posted
- Attached to
- RFP for Presentation Systems
- Solicitation number
- RFP MAT 200000001016 2
- Issued by
- Van Buren County, Michigan
About this file
This is a set of building maps and electrical power plans for the Early Childhood Educational Center and Athletic Team Room projects in Mattawan, Michigan, prepared for Mattawan Community Schools and Mattawan Consolidated Schools. The documents detail comprehensive audio/visual systems, electrical installations, and power distribution requirements across three building units (Units A, B, and C) for the educational center and a separate athletic facility. The scope includes installation of classroom and gymnasium projectors (minimum 3000 ANSI lumens), interactive displays, wireless microphone systems, audio amplification, Crestron control systems, LCD displays ranging from 42 to 65 inches, custom mobile lecterns with adjustable heights, speaker systems, and integrated technology infrastructure. Additionally, the athletic team room requires electrical panels, receptacles, HVAC connections, security systems, camera installations, and access control equipment distributed across locker rooms, training areas, restrooms, and storage spaces. All equipment installation requires coordination with building owners prior to final placement, field verification of actual locations, and comprehensive system testing including audio and video inputs and outputs.
The electrical work specifications require contractors to provide cutting, patching, final connections to all equipment, and fire rating maintenance at all penetrations. Power distribution includes new transformers, ground systems with exothermic welded connections, grounding rods, and multiple electrical panels (RP1, RP2, RP3, RP4, RP5, RP6, and P1) serving different building sections. GFCI protection is mandated for kitchen and bathroom receptacles with remote testing capabilities for inaccessible devices. All conduits must enter and exit below grade with trenching and directional boring as required, and no exposed exterior conduit is permitted. Fire alarm, low voltage communications, and security cabling must be run in conduit with appropriate separation and labeling. The projects include provisions for future expansion with spare circuit capacity in panelboards, and all work must comply with National Electrical Code requirements and coordinate with mechanical, controls, and architectural contractors throughout installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL DESCRIPTION
COMMUNICATIONS OUTLET IN WALL OR COMIBINED POWER SURFACE RACEWAY.
CLASSROOM/GYMNASIUM PROJECTOR LOCATION
TELEVISION
MARK DESCRIPTION MANUFACTURER
LARGE ROOM VIDEO PROJECTOR SHALL BE A MINIMUM OF 3000 ANSI LUMENS.
1280X800 NATIVE RESOLUTION. INSTALLTO THE CEILING OR AS NOTED.
PROVIDE WITH CUSTOM MOUNT AND CUSTOM LENS, VERIFY ACTUAL IN FIELD. EPSON
CLASSROOM VIDEO PROJECTOR SHORT THROW INTERACTIVE. SHALL BE A
MINIMUM OF 3000 ANSI LUMENS. 1280X800 NATIVE RESOLUTION. INSTALL TO
THE WALL. EPSON
PROJECTOR MOUNT, PROVIDE CUSTOM DOWNPIPE & PROJECTOR PLATE.
MOUNT TO BUILDING STRUCTURE CHIEF
AUDIO SYSTEM FOR CLASSROOM EQUIPMENT WITH ALL SPEAKER CABLING.
PROVIDE DROP DEILNG SPEAKERS OR CEILING SPEAKERS DEPENEDING ON
CEILING TYPE. FIELD VERIFY. FRONT ROW
USB HUB - HIGH POWERED 3.0 USB, MINIMUM 4 PORTS CONTRACTOR
TOUCHPANEL CONTROLLER WITH TABLETOP HOUSING FRONT ROW /RDL
4 PORT HDMI SWITCHER, FOUR INPUTS AND ONE OUTPUT. AUDIO DE-EMBED KEY-DIGITAL
PROJECTION SCREEN. SCREEN SHALL BE MOUNTED TO THE WALL. SCREEN
SHALL BE 16:10 FORMAT. DIAGONAL MEASURE OF 113". 60" HIGH X 96' WIDE. DA-LITE
UTP TO HDMI EXTENDER. POWERED FOR UP TO 100 FT TRANSMISSION. HDCP
COMPLIANT. INCLUDE CONTROL VIA RS-232 KEY DIGITAL
MOBILE LECTERN W/ ADJUSTABLE DESKTOP & AV SHELF. SEE DRAWING &
SPECS FOR DETAILS. INCLUDE A POWER STRIP & SO STYLE CORD. 15' LONG
MINIMUM SEE SPECS
USB TO UTP EXTENDER NETWORK TECHNOLOGIES
PLASTIC MESH CABLE PROTECTOR AND WRAP. SAMSUNG #HT40444 CABLE
FLEX WRAP TECH FLEX
WIRELESS MICROPHONE AND RECEIVER FRONT ROW
POWER AND INPUT/OUTPUT BOX FRONT ROW
POWER STRIP WITH RIGHT ANGLE OUTLETS, OUTLET QTY AS SHOWN ON
DRAWINGS. INCLUDE ON/OFF SWITCH. MOUNT TO SIDE OF LEXTERN OR INSIDE
AS SHOWN. TRIPP-LITE
CRESTRON CONTROL SYSTEM. INCLUDE ALL CARDS AND CABLES FOR
CONNECTION CRESTRON
COMMUNICATION SYMBOL LEGEND
A/V EQUIPMENT SCHEDULE
X
PRJ
VA
VB
VC
VD
VE
VF
VG
VH
VJ
VK
VL
VM
VN
VO
VP
VQ
TV
PAGING SYSTEM WITH BELLS AND BELL SCHEDULING SYSTEM VALCOM
DESKTOP MICROPHONE. CONNECT TO PAGING SYSTEM DIRECTLY SHURE
MATRIX HDMI SWITCHER KEY DIGITAL
POE BASED ETHERNET SWITCH FOR AUDIO/VIDEO/CONTROL CONNECTION CRESTRON
WALL MOUNT CABINET 4' TALL WITH MESH FRONT. GREAT LAKES
POWER STRIP - RACK MOUNT SURGEX
DRAWER FOR STORING MISCELLANEOUS AUDIO & VIDEO MATERIAL MIDDLE ATLANTIC
WIRED HANDHELD MICROPHONE, EQUIP WITH A 25' FLEXIBLE, SO STYLE CORD. AUDIX
WIRELESS MICROPHONE EXTENSION/COMBINER KIT. EXTEND MICROPHONES
TO GYM/CAF AREA WHEN REQUIRED FOR RECEIPTION. AUDIX
WIRELESS MICROPHONE PACKAGE SHALL CONSIST OF A TWO-CHANNEL RACK-
MOUNT RECEIVER, BELTPACK TRANSMITTER WITH HEADWORN MID AND A
SEPARATE HANDHELD MICROPHONE AUDIX
RACK MOUNT DIGITAL SIGNAL PROCESSOR AND MIXER. PROCESSOR SHALL BE
USED TO MIX THE INPUTS AND FINE TUNE THE AUDIO. BSS
THE AUDIO AMPLIFIERS FOR THE AUDIO SYSTEM SHALL BE SIZED TO PROVIDE
SUIFFICIENT POWER TO DRIVE ALL SPEAKERS AND PROVIDE 20% HEADROOM
ON EACH CIRCUIT CROWN
RACK MOUNT CD PLAYER SHALL HOLD ONE CD, SUPPORT BLUETOOTH,HAVE AN
IPOD DOCK, READ CR-RW, AND MP3'S TASCCAM
HDMI SPLITTER/DISTRIBUTION AMPLIFIER KEY DIGITAL
CUTOM INPUT PLATE FOR HDMI, MIC, AND AUDIO CONTRACTOR
TOUCH PANEL FOR A/V CONTROL CRESTRON
MARK DESCRIPTION MANUFACTURER
42" LCD EQUIP WITH A MOUNT. VERIFY PRIOR TO ORDERING NEC
46" LCD EQUIP WITH A MOUNT. VERIFY PRIOR TO ORDERING NEC
LCD DISPLAY EQUIPMENT SCHEDULE
VR
VS
VT
VU
WA
WB
WC
WD
WE
WF
WG
WH
WJ
WK
WM
WN
XA
XB
55" LCD EQUIP WITH A MOUNT. VERIFY PRIOR TO ORDERING NEC
65" LCD EQUIP WITH A MOUNT. VERIFY PRIOR TO ORDERING NEC
TILT WALL MOUNT FOR LCD 46" AND LARGER CHIEF
PULL OUT MOUNT FOR LCD 46" AND LARGER CHIEF
TILT WALL MOUNT CORRIDOR LCD'S CHIEF
MARK MANUFACTURER
1 SPEAKER CABLING, PENUM RATED, 18 AWG WEST PENN
CAT-6 PLENUM CABLE. BLUE FOR STANDARD DATA CONNECTIONS AND
PROJECTORS GENERAL CABLE
5 CAT-6 PLENUM CABLE. BLACK FOR AUDIO RECEIVER GENERAL CABLE
6 CAT-6 PLENUM CABLE. RED FOR HDMI EXTENSION GENERAL CABLE
7 HDMI CABLE, PLENUM RATED, LENGTH AS REQUIRED. NOT MORE THAN 35'
INSTALL ALL EQUIPMENT SHOWN. THE CONTRACTOR SHALL WALK THE
BUILDING WITH OWNER PRIOR TO INSTALLATION TO IDENTIFY ACTUAL
LOCATION OF ALL EQUIPEMNT.
SPEAKERS SHALL BE INSTALLED IN THE CEILING AND CONNECTED TO THE
AUDIO SYSTEM THAT IS IN THE LECTERN.
3 ALL CABLES FROM THE WALL TO THE LECTERN SHALL BE INSTALLED INSIDE A
NYLON MESH. TY/WRAP MESH AT EACH END TO SECURE BUNDLE.
4 INSTALL ALL PATCH CABLES SHOWN. CONNECT THE DEVICES AND FULLY TEST
THE SYSTEM INCLUDING ALL AUDIO AND VIDEO INPUTS AND OUTPUTS.
WORK WITH THE OWNER TO DETERMINE THE ACTUAL LOCATION OF THE
SCREEN AND PROJECTOR PRIOR TO INSTALLATION. PROVIDE ALL HARDWARE
REQUIRED TO SECURELY ATTACH THE PROJECTOR TO THE WALL.
INSTALL ALL CABLES INCLUDING POWER CABLE FROM THE WALL TO THE
LECTERN. ALL CABLES SHALL BE NO SHORTER THAN 15'.
INSTALL THE POWER STRIP. ATTACH THE POWER STRIP TO ONE OF THE
SHELVES. COORDINATE WITH THE DESIGNER PRIOR TO INSTALLATION.
A/V NOTES - CLASSROOM A/V
CABLING SCHEDULE
XC
XD
XE
XF
XG
A1
QTY DESCRIPTION MANUFACTURER PART#
1 FACEPLATE HUBBELL SS262
1 4-HOLE DECORA HUBBELL ISF40W
1 CAT-6 JACK-BLACK-HDMI HUBBELL HXJ6BK
1 CAT-6 CABLE-BLACK GENERAL 7131807
1 CAT-6 JACK-ORANGE-USB HUBBELL JXJ60R
1 CAT-T CABLE-ORANGE GENERAL 7131805
1 CAT-6 JACK-GREEN-SPKR HUBBELL HXJ6GN
1 CAT-6 CABLE-GREEN GENERAL 7131806
1 CAT-6 JACK-YELLOW-HDMI HUBBELL HXJ6Y
1 CAT-6 CABLE-YELLOW GENERAL 7131802
1 1-HOLE BULK VANCO 280311X
QTY DESCRIPTION MANUFACTURER PART#
2 SURFACE BOX HUBBELL ISB20W
2 CAT-6 JACK - ORANGE HUBBELL HXJ6OR
2 CAT-6 JACK -YELLOW HUBBELL HXJ6Y
SHORT THROW PROJECTOR - KEYED
NOTES
INSTALL THE SPLICE INSIDE OF A BACKBOX WITH COVER.
INSTALL WHITE (VERIFY COLOR WITH OWNER PRIOR TO INSTALLATION) MESH
AS YOU TRANSITION CABLES FORM THE CEILING TO THE PROJECTOR MOUNT.
INSTALL BLACK MESH FROM THE WALL TO THE LECTERN.
MOBILE LECTERN SHALL BE HEIGHT ADJUSTABLE AND SHALL BE ON WHEELS.
ALL EQUIPMENT SHALL BE MOUNTED TO A METAL "BREAD-BOARD" AND
ATTACHED TO THAT BOARD. THIS SHALL BE MODULAR AND SHALL
DISCONNECT FOR EASY WORK AND REPLACEMENT.
CUSTOMIZE THE FACEPLATE TO MATCH BACKBOX PROVIDED AND CABLES
REQUIRED TO BE TERMINATED.
PROVIDE FOUR SPEAKERS IN THE CEILING OF EACH CLASSROOM. CHECK TO SEE
IF THEY ARE DROP CEILING OR OPEN CEILING PRIOR TO ORDERING.
MOUNT ALL EQUIPMENT ONTO A REMOVABLE "BREADBOARD" WITH
DISCONNECTS SO IT CAN BE REMOVED IN ONE PIECE.
CUSTOM WEDGE TYPE MOUNT FOR TOUCHPANEL SHALL HAVE USB CHARGING
OUTLETS ON BOTH SIDES.
PARTS FOR PROJECTOR PLATE
PARTS FOR CLASSROOM A/V FACEPLATE
A2
CONTRACTOR SHALL PROVIDE AMPLIFIERS REQUIRED TO DRIVE THE AUDIO
SYSTEM.
USE MANUFACTURERS RECOMMENDED HARDWARE FOR MOUNTING ALL
SPEAKERS FROM THE BUILDING STRUCTURE.
3 LABEL ALL CONNECTION CABLES AT EACH END WITH PRE-PRINTED LABLES.
CONTRACTOR SHALL HANG AND AIM ALL SPEAKERS TO MAXIMIZE COVERAGE
AND PROVIDE THE BEST AUDIO POSSIBLE.
5 FULLY CONFIGURE THE SYSTEM FOR OPTIMUM AUDIO
FULLY CONFIGURE THE SOFTWARE CONTROL AND LOAD ON THE OWNERS
IPOD.
GYMNASIUM - KEYED NOTES
MOUNT CABINET ON THE WALL. COORDINATE WITH INCOMING CONDUITS
AND POWER.
INSTALL A BLANK PANEL AND MOUNT THE FACEPLATES FOR CONTROL ONTO
THE BLANK PANEL. LABEL EACH WITH AN ENGRAVED LABEL FOR WHAT THEY
CONTROL.
CONFIGURE PROJECTOR ON/OFF TO CONTROL PROJECTOR.
THE PROJECTOR SHALL BE CUSTOM INSTALLED WITH CORRECT LENS TO
MOUNT THE PROJECTOR HIGH IN THE CEILING AND THROW IMAGE TO LOW
AREA ON WALL.
COORDINATE PLATE LOCATIONS AND SIZES PRIOR TO ORDERING. REVIEW IN
FIELD.
MOUNT SPEAKERS IN CEILING. MOUNT WITH CUSTOM SUPPORTS. INCLUDE
SAFETY STRAP FOR EACH SPEAKER.
THE PROJECTOR SHALL BE MOUNTED IN THE CEILING AND BETWEEN THE
CLOUDS OF THE CEILING. CUSTOM INSTALL A DROP PIPE AND AIM THE
PROJECTOR DOWN TO THROW IMAGE
THE LECTERN SHALL BE MADE OF METAL WITH A LAMINATE TOP. METAL SHALL
BE BLACK OR STAINLESS STELL. TOP SHALL BE COMPATIBLE WITH OTHER
FURNITURE COLORS. REVIEW FURNITURE SPECS FOR DETAILS.
THE TOP SHALL BE ADJUSTABLE NO LESS THAN 10" UP AND DOWN. THIS SHALL
BE ABLE TO BE DONE BY THE TEACHER.
INSTALL GROMMETS TO ALLOW THE CABLES TO BE HIDDEN AS THEY ROUTE
FROM THE TOP TO THE INSIDE OF THE PODIUM.
FURNITURE SHALL BE DOUBLEDAY OR EQUAL. CONTACT THEM AT PHONE# 269-
926-8293. EXACTLY MATCH THOSE INSTALLED AT THE EARLY AND LATER
ELEMENTARY SCHOOLS.
GYMNASIUM AUDIO/VIDEO SYSTEM/SCHEMATIC
NOTES
TEACHER LECTERN LAYOUT NOTES
TS
H D
H D
H D
H D
S
F
S
F
F
F
F
F
F
F
F
S
F
F
S S
F
S
F
F
S
TS
TS
TS
S
TS TS
TS
F
F
F
F
F
S
S
S
S
S
S
S
S
FB
A
V V
F F
FF
F F
V
F
V
V
F
S FSS
V V
V
V
F F
F
F F
F F
S
S
S
V
S S
SS
S
S
S
S
S
S
S
S
S
S
S S
S
S S S S S S
VV
VV
TV
TV
CR
C R
C R
HH H
CR
CR IP
S
V
PRJ
S
PRJ
S
PRJ
S
PRJ
S
PRJ
S
PRJ
S
PRJ
S
C R
TS
TSTS
TS PRJ
S
PRJ
S
PRJ
S
PRJ
S
J
CR
FB
A
V
V
V
V
V
V
V
F
F
V
S
S
FB
A
FB
A
FB
A
FB
A
IP
IP
ICLG
J
J
J
TV
T
V
TV
J
J
J
J
J
J
J
J
T
EQ
DA
MS
V C
V C
V C
VC
VC
VC
T V
P R
J
P R
J
TV
CR
CR
CR
SD
S
S
CR
EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQEQ
EQ
EQ
SD
C R
EQ
TV
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
M
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
IDF
A152
EP2
TX-EP2
EM2
RP4
RP5PP
TX-RP5
VUV-A158
WP
WP
EP2- 1
GFI
EP2- 1
GFI
EP2- 1
GFI EP2- 1
GFI
GROUND BAR
GROUND BAR
RP5- 42
WP
RP5- 40
WP
MOUNT BELOW MARKER
BOARD 8" AFF
E 101B
U N
IT
B
U N
IT
A
U N
IT
B
U N
IT
A
W
LOW VOTLAGE WIRING
TO FLAG POLE.
FOOD
DIRECTOR
A111
FOOD
DIRECTOR
ASSIT.
A110
STORAGE
A109
CONFERENCE
A117
ASSISTANT
SUPERINTENDENT
A118
RECORDS
A119
FILES
A133
WORK ROOM
A134
TECH OFFICE
A132
STORAGE
A114
RP5- 39
GFI
WAITING
A108
BREAK ROOM
A107
IDF
A104
TLT.
A105
MENS
A106
WOMENS
A102
TLT.
A103
BOARD/CONF.
ROOM
A113
WORK ROOM
A120
FINANCE
DIRECTOR
A122
OFFICE
A123
OPEN OFFICE
A121
FINANCE
OFFICE
A124
HR OFFICE
A125
HR DIRECTOR
A127
FILES
A126
CONFERENCE
A129
S.S. DIRECTOR
OFFICE
A130
STUDENT
SERVICES
A128
S.S. OFFICE
A131
INTEGRATED
ARTS
A141
MEDIA CENTER
A142
YOUNG 5'S
CLASSROOM
A143
YOUNG 5'S
CLASSROOM
A144
YOUNG 5'S
CLASSROOM
A145
YOUNG 5'S
CLASSROOM
A146
PASSAGE
A140
4'S
CLASSROOM
A147
YOUNG 5'S
CLASSROOM
A148
ISD ROOM 1
A156
COMMONS
A151
IDF
A152
PEACE PLACE
A153 TOILET
A154
SPECIAL ED
CLASSROOM
A157
ISD ROOM 2
A158
RP4- 1
RP4- 1
RP4- 9
RP4- 9
RP4- 17 RP4- 19
RP4- 17
RP4- 19 RP4- 19
RP4- 21
RP4- 21
RP4- 21
RP4- 23
RP4- 23
GFI
RP4- 19
RP4- 25
RP4- 25 RP4- 27
RP4- 27
RP4- 27
RP4- 29
RP4- 29
RP4- 29
RP4- 31
RP4- 31
GFI
RP4- 27
RP4- 33
RP4- 33
RP4- 35
RP4- 35RP4- 35RP4- 35
RP4- 37
RP4- 37
RP4- 37
RP4- 39 RP4- 39
GFI
RP4- 2
RP4- 2
RP4- 10
RP4- 10
RP4- 18
RP4- 18
RP4- 20
RP4- 20 RP4- 20 RP4- 20
RP4- 22
RP4- 22
RP4- 22
RP4- 24
RP4- 24
GFI
RP4- 28
RP4- 28 RP4- 28
RP4- 26
RP4- 28 RP4- 26
RP4- 30
RP4- 30
RP4- 30
RP4- 32
RP4- 32
GFI
RP4- 34
RP4- 34
RP4- 36
RP4- 36 RP4- 36 RP4- 36
RP4- 38
RP4- 38
RP4- 38
RP4- 40RP4- 40
GFI
RP4- 48
GFI
RP4- 48
RP4- 46
RP4- 46
RP4- 46
RP4- 42
RP4- 44
RP4- 42
RP4- 44RP4- 44
FC-116
FC-115
FC-117
FC-108
FC-120
FC-123
FC-107
FC-121
FC-126
FC-129
FC-128
FC-A101A
FC-131
FC-133
FC-A101B
RP4- 3
RP4- 3RP4- 3RP4- 3
RP4- 5
RP4- 5
RP4- 5
RP4- 7
GFIRP4- 7
RP4- 13
RP4- 11
RP4- 11RP4- 11
RP4- 11
RP4- 13
RP4- 13
RP4- 15
RP4- 15
GFI
RP4- 4 RP4- 4 RP4- 4
RP4- 6
RP4- 6
RP4- 6
RP4- 8
RP4- 8
GFI
RP4- 14
RP4- 14
RP4- 14
RP4- 4
RP4- 12 RP4- 12 RP4- 12
RP4- 16
RP4- 16
GFI
RP4- 12
AC
LR
RXDC
2C
A100B
AC
LR
RXDC
1C
A113A
AC
LR
RX
2C
A101B
AC
LR
RX
RB
DC
2C
A100A
AC
LR
RX
RB
DC
1C
A135AAC
ML
LD
1D
A135B
AC
ML
LD
1D
A133A
AC
LR
RX
RB
DC
2C
A151
VESTIBULE
A100A
CONFERENCE
A112
RP4- 44
RP4- 19
RP4- 19
RP4- 19
SUPERINTENDENT
A116
RP4- 35
RP4- 35
RP4- 35
RP4- 27
RP4- 27
RP4- 27
GFI
RP4- 11
RP4- 11
RP4- 11
RP4- 3
RP4- 7
RP4- 7
EP2- 1
EP2- 1
EP2- 1
EP2- 2
EP2- 2 EP2- 2
EP2- 2
EP2- 15
EP2- 15EP2- 15 EP2- 15
EP2- 4
EP2- 4
EP2- 4
EP2- 4
EP2- 4
EP2- 6 EP2- 6 EP2- 6
EP2- 6
EP2- 6
EP2- 6
EP2- 5 EP2- 5
EP2- 5
EP2- 5 EP2- 5
EP2- 5 EP2- 5 EP2- 9 EP2- 9
EP2- 9 EP2- 9
EP2- 9
EP2- 9 EP2- 9
EP2- 8
EP2- 8
EP2- 8
EP2- 8
EP2- 8
EP2- 7
EP2- 7
EP2- 7
EP2- 7
EP2- 7
EP2- 7
EP2- 14EP2- 14
EP2- 14
GEN
FAA
EP2- 13
WP
WP
EP2- 15
EP2- 18
EP2- 18
EP2- 18
EP2- 18 EP2- 18
EP2- 18
EP2- 16EP2- 18 EP2- 18
EP2- 16EP2- 16
EP2- 17
EP2- 17
EP2- 17
EP2- 17
EP2- 17
EP2- 19
EP2- 17
EP2- 19
EP2- 20
EP2- 20 EP2- 20
EP2- 20
EP2- 20EP2- 20
EP2- 211
RP5- 1
RP5- 1
RP5- 1 RP5- 1
RP5- 2
RP5- 1
RP5- 1
RP5- 1
RP5- 1
RP5- 2
OPEN OFFICE /
WAITING
A115
RP5- 4 RP5- 4
RP5- 4 RP5- 4
RP5- 4
RP5- 5
RP5- 5
RP5- 5
RP5- 5
RP5- 6
RP5- 10
RP5- 7
RP5- 7
RP5- 10
RP5- 8
RP5- 8
RP5- 10
RP5- 8
RP5- 9
RP5- 9
RP5- 10
W
W
W
4 2
2 2
W
2 2EP2- 12
EP2- 12
EP2- 12
EP2- 12
EP2- 12
EP2- 11
EP2- 11
EP2- 11
EP2- 11
EP2- 11
EP2- 10
EP2- 10
EP2- 10
EP2- 10
EP2- 10
RP5- 12
RP5- 12
RP5- 11
RP5- 11
EP2- 7
EP2- 7
RP5- 18
RP5- 18 RP5- 18
RP5- 18
EP2- 7
RP5- 19
RP5- 19
RP5- 20
RP5- 19
RP5- 19
RP5- 19
RP5- 19
RP5- 20
RP5- 20
RP5- 20
RP5- 20
RP5- 20
RP5- 20
RP5- 20 EP2- 11EP2- 11
RP5- 15
RP5- 16
RP5- 16
RP5- 16
RP5- 14 RP5- 14
RP5- 14
RP5- 14
RP5- 14
RP5- 13
RP5- 13
RP5- 14
RP5- 21 RP5- 22
RP5- 21
RP5- 22 RP5- 23
RP5- 23
RP5- 24
RP5- 24
RP5- 24
FLAG POLE
RP5- 24
EP2- 22
EP2- 22
RP5- 25
RP5- 25
RP5- 25
RP5- 25
RP5- 25
RP5- 26 RP5- 26
RP5- 26
RP5- 25
RP5- 26
RP5- 25
RP5- 26
RP5- 26
RP5- 27
RP5- 27RP5- 27
RP5- 27
RP5- 27
EP2- 23
EP2- 23
EP2- 23
EP2- 23EP2- 23
EP2- 23
RP5- 30
RP5- 30
RP5- 31
GFI
RP5- 32
GFI
RP5- 29
RP5- 33
GFI
RP5- 34
GFI
RP5- 28 RP5- 28
RP5- 28
RP5- 28
RP5- 36
RP5- 35
RP5- 37
RP5- 38
A
RP4- 3
A
RP4- 4RP4- 3 RP4- 4
A
RP4- 11 RP4- 11
A
RP4- 12RP4- 12
RP4- 19
A
RP4- 19 RP4- 20
A
RP4- 20
A
RP4- 27 RP4- 27 RP4- 28
A
RP4- 28
RP5- 39
EWC
RP5- 40RP5- 40
RP5- 41 RP5- 41 RP5- 41
RP4- 36
A
RP4- 36
RP4- 35
A
RP4- 35 RP4- 44
A
RP4- 44
RP4- 11
RP5- 20
EP1- 1
EP1- 2
EP1- 3
RP4- 41
W
W
W
W
W
W
W
W
W
W
W
2 2
RP5- 14
W
VUV-A113BVUV-A113A
CUH-1
EM2- 8 EM2- 9
EP2- 24
EP2- 25
EP2- 26
FC-110
EP2- 27
EP2- 27
EP2- 28
EP2- 29
EP2- 30
EP2- 30
EP2- 31
EP2- 31
EP2- 32
EP2- 32
EP2- 33
EP2- 33 EP2- 34
EP2- 34
FC-135B
EP2- 35
EP2- 35
FC-135A
EP2- 36
CUH-1
EP2- 14
EP2- 18 EP2- 37
EP2- 39
EP2- 38
EP2- 40
EP2- 41
GFI
SS-1
EP2- 41
EP2- 43,45
VUV-A141
EM2- 10
VUV-A143
EM2- 11
VUV-A142
EM2- 12
VUV-A144
EM2- 13
VUV-A146
EM1- 19
VUV-A148
VUV-A156
EM1- 21
EM1- 22
VUV-A157
EM1- 24
VUV-A147
EM1- 25
VUV-A145
EM1- 26
FACP
EP1- 22
RECEPTION
A135
AC
LR
RX
2C
A101A
FC-130
EP2- 46
W
W
FC-112
FC-124
EP2- 4
2 2
EP2- 47
FC-118
FC-140A
EP2- 48
EP1- 32
EP1- 33
AC
LR
RXDC
2C
A101C
FC-151A EP1- 48
FC-140B
EP1- 49
FC-140C
EP1- 50
EP2- 49
EP2- 18
FC-151B
EP1- 55
CP-1
EP2- 41
CONDUITS SHALL
ENTER BUILDING
BELOW GRADE.
PP- 2,4,6
RP5- 17
MICRO
RP5- 43
GFI
RP5- 43
EWC
(3) 4" CONDUITS
(3) 4" CONDUITS(3) 4" CONDUITS
E a s t
K a la m a z o o A v e n u e
S u it e
K a la m a z o o
M ic h ig a n
-5
.3
.6
P H
O N
E
.3
.6
F A
X
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
E a s t
F u lt o n S tr e e t, S u it e
G ra n d R a p id s
M ic h ig a n
.4
.9
P H
O
.4
.5
F A
X
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F
IR
S T
F L
O O
R P
O W
E R
P L
A N
U
N
IT
A
-1
.5
E
A S
E P
T E
M B
E R
E A
R L
Y C
H
IL
D H
O O
D E
D U
C A
T
IO
N A
L C
E N
T E
R
M a tt a w a n
M I
M A
T T
A W
A N
C O
M M
U N
IT
Y
S C
H O
O L
S
GENERAL ELECTRICAL NOTES
ELECTRICAL KEYED NOTES
1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING
AND PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE
REMOVED AND NOT REPLACED.
2 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED
EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH
EQUIPMENT, ADJUST CIRCUIT SIZE AS REQUIRED.
3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.
4 REFER TO INTERIOR ELEVATIONS, SECTIONS, ARCHITECTURAL
ELEVATIONS AND RELATED DRAWINGS FOR EXACT DEVICE LOCATIONS
AND MOUNTING HEIGHTS. WHERE DEVICES ARE MOUNTED UNDER OR
ABOVE TACK BOARDS, DOORS, WINDOWS, OR ANY PIECE OF
EQUIPMENT, THE ELECTRICAL DEVICE SHALL BE CENTERED AS SHOWN.
COORDINATE LOCATION OF FURNITURE CONNECTIONS AND/OR
RECEPTACLES AND DATA RACEWAYS WITH APPROVED FURNITURE
SHOP DRAWINGS, FINAL CONNECTIONS TO FURNITURE BY ELECTRICAL
CONTRACTOR.
5 ALL CONDUITS SHALL RUN AS NEAR TO DECK AS PERMITTED BY CODE.
SOME CONDUITS WILL BE EXPOSED AND SHALL BE RUN IN A NEAT
MANNER. MAINTAIN THE SAME SPACING WHEN CONDUITS ARE RUN
TOGETHER. CONCEAL JUNCTION BOXES OVER LAY-IN CEILING AND
USE EMT DROPS DOWN TO CLOUDS. LOCATE CONDUIT DROPS TO
CLOUDS AND CEILING ELEMENTS IN LEAST VISIBLE LOCATION.
6 ALL KITCHEN RECEPTACLES TO BE GFCI PROTECTED PER NEC
REQUIREMENTS. PROVIDE REMOTE GFCI TESTING DEVICE FOR
INNACCESSIBLE GFCI DEVICES.
7 ALL FIRE ALARM PULL STATIONS TO HAVE PLASTIC COVERS WITH
ALARM.
8 ALL FIRE ALARM CABLING SHALL BE RUN IN CONDUIT. FIRE ALARM
CABLING IS PERMITTED TO BE IN CABLE TRAY WITH SEPARATION FROM
BUILDING AND COMMUNICATION CABLING.
9 ALL LOW VOLTAGE CABLING SHALL BE RUN IN CONDUIT BETWEEN
DEVICE AND CABLE TRAY OR TECHNOLOGY RACK. NO CABLING SHALL
BE VISIBLE IN EXPOSED CEILING SPACES. EXPOSED CONDUIT SHALL
BE PAINTED TO MATCH SURFACE IT IS SUPPORTED FROM. WIRING
ROUTED IN ACCESSIBLE CEILING SPACES SHALL BE INDEPENDENTLY
SUPPORTED WITH COMM HOOKS OR RINGS.
10 CONNECT POWER TO ALL TERMINAL UNITS PROVIDED BY MECHANICAL,
COORDINATE TRANSFORMER QUANTITIES AND LOCATIONS WITH
MECHANICAL CONTRACTOR.
11 CONNECT BAS CONTROL PANEL TO EMERGENCY CIRCUIT (IF
AVAILABLE) AND COORDINATE BAS PANEL LOCATION WITH CONTROLS
CONTRACTOR.
12 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.
PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT
AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED
ON EXTERIOR OF BUILDING.
13 PROVIDE 120V CIRCUIT FROM NEAREST GENERATOR STANDBY PANEL
FOR ALL BMS/BAS CONTROL PANELS. COORDINATE LOCATION AND
NUMBER OF CIRCUITS WITH CONTROLS CONTRACTOR.
14 PROVIDE 120V CIRCUIT FROM NEAREST LIFE SAFETY PANEL FOR ALL
FIRE ALARM NAC PANELS. COORDINATE WITH FIRE ALARM
CONTRACTOR FOR LOCATIONS AND NUMBER OF CIRCUITS.
15 PROVIDE 4" HOUSEKEEPING PADS FOR SWITCHGEAR, TRANSFORMERS
AND ALL FLOOR MOUNTED EQUIPMENT. PROVIDE FLEXIBLE
CONNECTION TO TRANSFORMERS AND SIMILAR EQUIPMENT PER
SPECIFICATIONS.
16 RECESS NEW DEVICES AND ASSOCIATED CONDUITS AND BACKBOX IN
EXISTING WALLS WHERE POSSIBLE. CUT AND PATCH AS REQUIRED.
1 FEED FROM GFI TYPE CIRCUIT BREAKER. LABEL RECEPTACLE COVER,
GFI PROTECTED.
2 FLOOR BOX SHALL BE WIREMOLD #EFB8S-OG PROVIDE WITH SIX
DUPLEX RECEPTACLES AND TWO DATA PLATES. PROVIDE DIVIDER AS
REQUIRED FOR ONE SIDE. PROVIDE TUNNEL AS REQUIRED. PROVIDE
WHITE DEVICES AND WHITE COVER PLATES AS REQUIRED. COVER
SHALL BE #EFB610BTCGY. PROVIDE ALL REQUIRED EQUIPMENT FOR A
COMPLETE INSTALLATION. COORDINATE FINAL LOCATION IN FIELD
WITH FURNITURE INSTALLER. PROVIDE (2) 11/4" CONDUITS TO
ACCESSIBLE CEILING FOR COMMUNICATIONS WIRING.
3 PROVIDE OUTLET BELOW SINK FOR AUTOMATIC FAUCET. COORDINATE
LOCATION WITH SINKS AND PIPING. CONNECT TO LOAD SIDE OF
ADJACENT GFI TYPE RECEPTACLE.
4 PROVIDE 120V CIRCUIT TO AUTOMATIC DOOR. CONCEAL ALL
CONDUIT WITHIN MULLION. NO CONDUIT SHALL BE EXPOSED.
PROVIDE 1" CONDUIT FROM DOOR CONTROL TO NEAREST ACCESSIBLE
CEILING FOR DATA WIRING.
1/8" = 1'-0"
FIRST FLOOR POWER PLAN - UNIT A
EARLY CHILDHOOD
EDUCATIONAL CENTER
KEY PLAN
SCALE: NO SCALE
UNIT A
UNIT B
UNIT C
ISSUED FOR DATE
ADDENDUM 1 10-02-2019
ADDENDUM 2 10-10-2019
BULLETIN 2 01-17-2020
Tony Nuismer
XC
Tony Nuismer
XC
Tony Nuismer
XC
Tony Nuismer
XC
Tony Nuismer
XC
Tony Nuismer
XC
Tony Nuismer
Tony Nuismer
PRJ
Tony Nuismer
TS
Tony Nuismer
Tony Nuismer
XC
Tony Nuismer
XC
Tony Nuismer
Tony Nuismer
W /D
W
UP
S B
P R
J
T S S
TS
S
S B
T S S
P R
J
T
SS
T
SS
TS
S
T
SS
TS
S
TS
S
HD HD
HD HD
F
F
F F
F
F
F
F
F
F F
F
F
F
F
S
F
TS
S
TS
TS
F F F
F
F
S
S
EQ
EQ
F
F
C R
C R
C R
C R
C R
F
S
S
S
SF
S
F
F
S
F
S
S
S
F
F
FSFS FS SS
S
F
F
FS
FS
FS
S
FS F S
FS
FS
F
S
F
S
F
S
IP
C R
CR
IP
C R
PRJ
S
PRJ
S
PRJ
S
F CR
ML
C R
C R
IP
LGIC
J J
J
F
F
D A
M S
CR
T V
T V
SD
S
J
J
F
CR
C R
F
WF WF WF
OSY OSY
EQ
EQEQ
EQ
M M
S S S
EQ
TV
EQ
EQ
EQ
EQ
EQ
EQ EQ
FB
A
EQ
EQ
EQ
EQ
EQ
M
SD
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
M
D H
D H
SD
C R
MDPTX-DP1 DP1
EM1
ATS-2
EL
ATS-1
GENERATOR
TX-MDP
EP1
L
RP3
TX-EP1
WG
WG
WG
WG
WP
BUILDING
GROUND BAR
GROUND BAR
#3/0 GROUND
IN 1" PVC.
12" CABLE
TRAY TYPICAL
GROUND BAR
E 101B
U N
IT
B
U N
IT
A
U N
IT C
U N
IT B
U N
IT C
U N
IT B
U N
IT
B
U N
IT
A
W
W
A
W
JANITOR
CLOSET
B128
MEETING
B126
ISD ROOM 3
B105
GIRLS
B125
BOYS
B124
CORRIDOR
B101
OT/PT
B106
VESTIBULE
B100
OFFICE
B107
RP4- 33
RP4- 33
RP4- 35
RP4- 35RP4- 35RP4- 35
RP4- 37
RP4- 46
RP4- 42
RP4- 44
RP4- 42
RP4- 44RP4- 44
RP4- 56
RP4- 56 RP4- 56 RP4- 56
RP4- 54
RP4- 54
RP4- 54
RP4- 50
RP4- 52
RP4- 50
RP4- 52
GFI
AC
LR
RX
2C
B101C
AC
LR
RX
1C
B101A
AC
LR
RX
1C
B101B
AC
LR
RX
RB
DC
1C
B107A
AC
LR
RX
RB
DC
1C
B100B
AC
LR
RXDC
1C
B100A
AC
ML
LD
1D
B107B
AC
LR
RX
RB
DC
2C
B102A
AC
DC
1C
A328
AC
LR
RX
RB
DC
2C
C100A
AC
LR
RXDC
1C
C101B
AC
LR
RX
2C
C100B
AC
DC
2C
B130A
RP3- 16
GFI
RP3- 16
EWC
RP4- 44RP4- 35
DIRECTOR
B109
MDF
B140
FAA
WP
RP4- 35
A
RP4- 35 RP4- 44
A
RP4- 44
RP4- 41 RP4- 41
RP4- 41
A
RP4- 56RP4- 56
RP4- 43
RP4- 43
RP4- 43
RP4- 43
RP4- 43
EP1- 4
GFI
EP1- 4
GFI
RP3- 1
RP3- 2
RP3- 3RP3- 4
RP3- 5,7
RP3- 12
RP3- 12
RP3- 6
W
W
W
EP1- 5 1
RP3- 12RP3- 8
GFI
RP3- 9
GFI
RP3- 10
GFI
RP3- 11
GFI
EP1- 6
GFI
EP1- 6
GFI
EP1- 7
GFI
EP1- 7
GFI
EP1- 7
GFI
EP1- 11 EP1- 8
W
EP1- 10
EP1- 9
RP3- 14 RP3- 14 RP3- 15
RP3- 15
RP3- 15
RP3- 15
RP3- 15
RP3- 14
RP3- 14
RP3- 15
EP1- 12
EP1- 12
EP1- 12
EP1- 13
EP1- 13
EP1- 15
EP1- 15
EP1- 15EP1- 15EP1- 15
EP1- 14EP1- 14
EP1- 13
EP1- 16
EP1- 16
EP1- 16
EP1- 16
EP1- 161
W
EP1- 17
EP1- 17
EP1- 17
EP1- 17
EP1- 17
EP1- 17
EP1- 18
EP1- 18
EP1- 18
EP1- 18
EP1- 18
EP1- 18
EP1- 19
EP1- 19
EP1- 19
W
W
W 1
W
W
AC
LR
RX
2C
B120C
RP3- 12
EP1- 11
CLASSROOM
B131
CLASSROOM
B132
CLASSROOM
B133
CORRIDOR
B103
CORRIDOR
C100
STORAGE
B134
STORAGE
B137
STOR.
B135
STORAGE
B139
STOR.
B144
STOR.
B143
STOR.
B142
STOR.
B115
STOR.
B116
GENERAL
STORAGE
B114B
VESTIBULE
B102
VUV-B104
EM1- 23
MDP
MDP
EM1- 28,30,32
EM1- 27,29,31
EP1- 21
EP1- 20
RP3- 12
BOILER EM
SHUT OFF
BOILER EM
SHUT OFF
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING
DEMOLISHED, TO NEW PANEL RP1.
CONTRACTOR TO FIELD VERIFY EXACT
LOCATIONS AND QUANTITITES.
RP1
GYM STORAGE
/ UTILITIES
B117
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP1. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP3. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP3. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP3. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP1. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP1. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP1. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP3. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RP1- 1
WP
RP1- 1
WP
EP1- 23
RP3- 19
WHERE LATCH RETRACTION IS
SPECIFICALLY SHOWN WITH A
DASHED LINE, JUST THAT DOOR
HAS LATCH RETRACTION. ALL
OTHERS SHALL HAVE BOTH
LEAFS.
EP1- 17
RP3- 12
RP3- 13
RP3- 13
W
EP1- 34
FC-101A
EP1- 35
EP1- 36EP1- 37
EP1- 40
AC
LR
RX
1C
B110A
AC
LR
RX
2C
B102B
EP1- 41
EP1- 42,44
EP1- 17
MECHANICAL
B130
BREAK/WORK
ROOM
B129
FC-140C
EP1- 50
FC-104
QUIET ROOM
B127
RP4- 41
RP4- 41
FC-105
EP1- 51
CUH-1
EP1- 12
FC-B106
EP1- 52
FC-B129
EP1- 53
FC-151C
CUH-1
EP1- 19
FC-B108
EP1- 54
FC-100C
FC-100B
WH-2 CP-2
EP1- 56
EP1- 56
AC
LR
RX
2C
B101D
AC
LR
RX
RB
DC
1C
B104
EP1- 57
SMP-1
BLUE
10'-0" AFF
(3) 4" CONDUITS
(3) 4" CONDUITS
(3) 4" CONDUITS
AC
LR
RX
DH
2C
B103
GENERATOR
DOCKING STATION
RP4- 41
RP4- 41
RP4- 43
WIREMOLD 500
WIREMOLD 4000
DIVIDED RACEWAY
WIREMOLD 500 TO
ADJACENT DEVICES
E a s t
K a la m a z o o A v e n u e
S u it e
K a la m a z o o
M ic h ig
-5
.3
.6
P H
O
.3
.6
F A
X
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
E a s t
F u lt o n S tr e e t, S u it e
G ra n d R a p id s
M ic h ig a n
.4
.9
P H
O
.4
.5
F A
X
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F
IR
S T
F L
O O
R P
O W
E R
P L
A N
U
N
IT
B
-1
.5
E
B S
E P
T E
M B
E R
E A
R L
Y C
H
IL
D H
O O
D E
D U
C A
T
IO
N A
L C
E N
T E
R
M a tt a w a n
M I
M A
T T
A W
A N
C O
M M
U N
IT
Y
S C
H O
O L
S
1/8" = 1'-0"
FIRST FLOOR POWER PLAN - UNIT B
EARLY CHILDHOOD
EDUCATIONAL CENTER
KEY PLAN
SCALE: NO SCALE
UNIT A
UNIT B
UNIT C
GENERAL ELECTRICAL NOTES
ELECTRICAL KEYED NOTES
1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING
AND PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE
REMOVED AND NOT REPLACED.
2 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED
EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH
EQUIPMENT, ADJUST CIRCUIT SIZE AS REQUIRED.
3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.
4 REFER TO INTERIOR ELEVATIONS, SECTIONS, ARCHITECTURAL
ELEVATIONS AND RELATED DRAWINGS FOR EXACT DEVICE LOCATIONS
AND MOUNTING HEIGHTS. WHERE DEVICES ARE MOUNTED UNDER OR
ABOVE TACK BOARDS, DOORS, WINDOWS, OR ANY PIECE OF
EQUIPMENT, THE ELECTRICAL DEVICE SHALL BE CENTERED AS SHOWN.
COORDINATE LOCATION OF FURNITURE CONNECTIONS AND/OR
RECEPTACLES AND DATA RACEWAYS WITH APPROVED FURNITURE
SHOP DRAWINGS, FINAL CONNECTIONS TO FURNITURE BY ELECTRICAL
CONTRACTOR.
5 ALL CONDUITS SHALL RUN AS NEAR TO DECK AS PERMITTED BY CODE.
SOME CONDUITS WILL BE EXPOSED AND SHALL BE RUN IN A NEAT
MANNER. MAINTAIN THE SAME SPACING WHEN CONDUITS ARE RUN
TOGETHER. CONCEAL JUNCTION BOXES OVER LAY-IN CEILING AND
USE EMT DROPS DOWN TO CLOUDS. LOCATE CONDUIT DROPS TO
CLOUDS AND CEILING ELEMENTS IN LEAST VISIBLE LOCATION.
6 ALL KITCHEN RECEPTACLES TO BE GFCI PROTECTED PER NEC
REQUIREMENTS. PROVIDE REMOTE GFCI TESTING DEVICE FOR
INNACCESSIBLE GFCI DEVICES.
7 ALL FIRE ALARM PULL STATIONS TO HAVE PLASTIC COVERS WITH
ALARM.
8 ALL FIRE ALARM CABLING SHALL BE RUN IN CONDUIT. FIRE ALARM
CABLING IS PERMITTED TO BE IN CABLE TRAY WITH SEPARATION FROM
BUILDING AND COMMUNICATION CABLING.
9 ALL LOW VOLTAGE CABLING SHALL BE RUN IN CONDUIT BETWEEN
DEVICE AND CABLE TRAY OR TECHNOLOGY RACK. NO CABLING SHALL
BE VISIBLE IN EXPOSED CEILING SPACES. EXPOSED CONDUIT SHALL
BE PAINTED TO MATCH SURFACE IT IS SUPPORTED FROM. WIRING
ROUTED IN ACCESSIBLE CEILING SPACES SHALL BE INDEPENDENTLY
SUPPORTED WITH COMM HOOKS OR RINGS.
10 CONNECT POWER TO ALL TERMINAL UNITS PROVIDED BY MECHANICAL,
COORDINATE TRANSFORMER QUANTITIES AND LOCATIONS WITH
MECHANICAL CONTRACTOR.
11 CONNECT BAS CONTROL PANEL TO EMERGENCY CIRCUIT (IF
AVAILABLE) AND COORDINATE BAS PANEL LOCATION WITH CONTROLS
CONTRACTOR.
12 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.
PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT
AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED
ON EXTERIOR OF BUILDING.
13 PROVIDE 120V CIRCUIT FROM NEAREST GENERATOR STANDBY PANEL
FOR ALL BMS/BAS CONTROL PANELS. COORDINATE LOCATION AND
NUMBER OF CIRCUITS WITH CONTROLS CONTRACTOR.
14 PROVIDE 120V CIRCUIT FROM NEAREST LIFE SAFETY PANEL FOR ALL
FIRE ALARM NAC PANELS. COORDINATE WITH FIRE ALARM
CONTRACTOR FOR LOCATIONS AND NUMBER OF CIRCUITS.
15 PROVIDE 4" HOUSEKEEPING PADS FOR SWITCHGEAR, TRANSFORMERS
AND ALL FLOOR MOUNTED EQUIPMENT. PROVIDE FLEXIBLE
CONNECTION TO TRANSFORMERS AND SIMILAR EQUIPMENT PER
SPECIFICATIONS.
16 RECESS NEW DEVICES AND ASSOCIATED CONDUITS AND BACKBOX IN
EXISTING WALLS WHERE POSSIBLE. CUT AND PATCH AS REQUIRED.
1 FEED FROM GFI TYPE CIRCUIT BREAKER. LABEL RECEPTACLE COVER,
GFI PROTECTED.
2 FLOOR BOX SHALL BE WIREMOLD #EFB8S-OG PROVIDE WITH SIX
DUPLEX RECEPTACLES AND TWO DATA PLATES. PROVIDE DIVIDER AS
REQUIRED FOR ONE SIDE. PROVIDE TUNNEL AS REQUIRED. PROVIDE
WHITE DEVICES AND WHITE COVER PLATES AS REQUIRED. COVER
SHALL BE #EFB610BTCGY. PROVIDE ALL REQUIRED EQUIPMENT FOR A
COMPLETE INSTALLATION. COORDINATE FINAL LOCATION IN FIELD
WITH FURNITURE INSTALLER. PROVIDE (2) 11/4" CONDUITS TO
ACCESSIBLE CEILING FOR COMMUNICATIONS WIRING.
3 PROVIDE OUTLET BELOW SINK FOR AUTOMATIC FAUCET. COORDINATE
LOCATION WITH SINKS AND PIPING. CONNECT TO LOAD SIDE OF
ADJACENT GFI TYPE RECEPTACLE.
4 PROVIDE 120V CIRCUIT TO AUTOMATIC DOOR. CONCEAL ALL
CONDUIT WITHIN MULLION. NO CONDUIT SHALL BE EXPOSED.
PROVIDE 1" CONDUIT FROM DOOR CONTROL TO NEAREST ACCESSIBLE
CEILING FOR DATA WIRING.
1/4" = 1'-0"E 101B
2 TEACHING WALL ELEVATION
ISSUED FOR DATE
ADDENDUM 1 10-02-2019
ADDENDUM 2 10-10-2019
BULLETIN 2 01-17-2020
Tony Nuismer
Tony Nuismer
PRJ
Tony Nuismer Include as an alternate
Tony Nuismer
XC
Tony Nuismer
XC
XC
S B
T S S
P R
J
T
SS
TS
S
TS
S
TS
S
TS
TS SB
PRJ
F
F F
HDHD
HDHD
F
C R
C R
F
F
F
F
F
F
V
F
F
S
S
S
S
S
C R
FS S
FS
F S
F S
F
F
S
F
S
F
S
C R
S
S
S
S
S
S
S
S
F
S S
EQ
EQ
EQ
EQ
EQ
EQ
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
SD
CO
D H
D H
SD
C R
RP2
RP6
CORRIDOR
C101
12" CABLE
TRAY TYPICAL
12" CABLE
TRAY TYPICAL
U N
IT C
U N
IT B
U N
IT C
U N
IT B
W
AC
LR
RX
RB
DC
2C
C100A
AC
LR
RXDC
1C
C101B
AC
LR
RX
2C
C100B
W
W
W
W CLASSROOM
B132
CLASSROOM
B133
CLASSROOM
C102
CLASSROOM
C103
GIRLS
C104
CORRIDOR
C100
STORAGE
B134
STORAGE
B137
STOR.
B135
FOOD PANTRY
C112
FOOD PACKS
C113
STORAGE
C111
FOOD PANTRY
C110
FOOD PANTRY
WORK ROOM
C108
SUPPLIES FOR
SUCCESS
C109
BOYS
C106
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING
DEMOLISHED, TO NEW PANEL RP1.
CONTRACTOR TO FIELD VERIFY EXACT
LOCATIONS AND QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP3. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
RECIRCUIT ALL DEVICES LOCATED IN
THIS ROOM, NOT BEING DEMOLISHED,
TO NEW PANEL RP3. CONTRACTOR TO
FIELD VERIFY EXACT LOCATIONS AND
QUANTITITES.
EP1- 23
EP1- 25,27
FREEZER BLOWER
EP1- 29
FREEZER DOOR
EP1- 31EP1- 30
FEED WITH #10 WIRE.
PROVIDE CORD DROP
WITH STRAIN RELEAF.
AC
LR
RXDC
2C
C101A
W
W
W
W
W
W
W
W
EP1- 37
EP1- 39
EP1- 46 EP1- 47
FC-100C
FC-101
FC-100B
RP6- 3
GFI
BLUE
10'-0" AFF
(3) 4" CONDUITS
(3) 4" CONDUITS
AC
LR
RX
DH
2C
B103
CP-3
E a s t
K a la m a z o o A v e n u e
S u it e
K a la m a z o o
M ic h ig
-5
.3
.6
P H
O
.3
.6
F A
X
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
E a s t
F u lt o n S tr e e t, S u it e
G ra n d R a p id s
M ic h ig a n
.4
.9
P H
O
.4
.5
F A
X
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F
IR
S T
F L
O O
R P
O W
E R
P L A
N
U N
IT
C
-1
.5
E
C
S E
P T
E M
B E
R
E A
R L
Y C
H
IL
D H
O O
D E
D U
C A
T
IO
N A
L C
E N
T E
R
M a tt a w a n
M I
M A
T T
A W
A N
C O
M M
U N
IT
Y
S C
H O
O L
S
1/8" = 1'-0"
FIRST FLOOR POWER PLAN
EARLY CHILDHOOD
EDUCATIONAL CENTER
KEY PLAN
SCALE: NO SCALE
UNIT A
UNIT B
UNIT C
GENERAL ELECTRICAL NOTES
ELECTRICAL KEYED NOTES
1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING
AND PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE
REMOVED AND NOT REPLACED.
2 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED
EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH
EQUIPMENT, ADJUST CIRCUIT SIZE AS REQUIRED.
3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.
4 REFER TO INTERIOR ELEVATIONS, SECTIONS, ARCHITECTURAL
ELEVATIONS AND RELATED DRAWINGS FOR EXACT DEVICE LOCATIONS
AND MOUNTING HEIGHTS. WHERE DEVICES ARE MOUNTED UNDER OR
ABOVE TACK BOARDS, DOORS, WINDOWS, OR ANY PIECE OF
EQUIPMENT, THE ELECTRICAL DEVICE SHALL BE CENTERED AS SHOWN.
COORDINATE LOCATION OF FURNITURE CONNECTIONS AND/OR
RECEPTACLES AND DATA RACEWAYS WITH APPROVED FURNITURE
SHOP DRAWINGS, FINAL CONNECTIONS TO FURNITURE BY ELECTRICAL
CONTRACTOR.
5 ALL CONDUITS SHALL RUN AS NEAR TO DECK AS PERMITTED BY CODE.
SOME CONDUITS WILL BE EXPOSED AND SHALL BE RUN IN A NEAT
MANNER. MAINTAIN THE SAME SPACING WHEN CONDUITS ARE RUN
TOGETHER. CONCEAL JUNCTION BOXES OVER LAY-IN CEILING AND
USE EMT DROPS DOWN TO CLOUDS. LOCATE CONDUIT DROPS TO
CLOUDS AND CEILING ELEMENTS IN LEAST VISIBLE LOCATION.
6 ALL KITCHEN RECEPTACLES TO BE GFCI PROTECTED PER NEC
REQUIREMENTS. PROVIDE REMOTE GFCI TESTING DEVICE FOR
INNACCESSIBLE GFCI DEVICES.
7 ALL FIRE ALARM PULL STATIONS TO HAVE PLASTIC COVERS WITH
ALARM.
8 ALL FIRE ALARM CABLING SHALL BE RUN IN CONDUIT. FIRE ALARM
CABLING IS PERMITTED TO BE IN CABLE TRAY WITH SEPARATION FROM
BUILDING AND COMMUNICATION CABLING.
9 ALL LOW VOLTAGE CABLING SHALL BE RUN IN CONDUIT BETWEEN
DEVICE AND CABLE TRAY OR TECHNOLOGY RACK. NO CABLING SHALL
BE VISIBLE IN EXPOSED CEILING SPACES. EXPOSED CONDUIT SHALL
BE PAINTED TO MATCH SURFACE IT IS SUPPORTED FROM. WIRING
ROUTED IN ACCESSIBLE CEILING SPACES SHALL BE INDEPENDENTLY
SUPPORTED WITH COMM HOOKS OR RINGS.
10 CONNECT POWER TO ALL TERMINAL UNITS PROVIDED BY MECHANICAL,
COORDINATE TRANSFORMER QUANTITIES AND LOCATIONS WITH
MECHANICAL CONTRACTOR.
11 CONNECT BAS CONTROL PANEL TO EMERGENCY CIRCUIT (IF
AVAILABLE) AND COORDINATE BAS PANEL LOCATION WITH CONTROLS
CONTRACTOR.
12 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.
PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT
AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED
ON EXTERIOR OF BUILDING.
13 PROVIDE 120V CIRCUIT FROM NEAREST GENERATOR STANDBY PANEL
FOR ALL BMS/BAS CONTROL PANELS. COORDINATE LOCATION AND
NUMBER OF CIRCUITS WITH CONTROLS CONTRACTOR.
14 PROVIDE 120V CIRCUIT FROM NEAREST LIFE SAFETY PANEL FOR ALL
FIRE ALARM NAC PANELS. COORDINATE WITH FIRE ALARM
CONTRACTOR FOR LOCATIONS AND NUMBER OF CIRCUITS.
15 PROVIDE 4" HOUSEKEEPING PADS FOR SWITCHGEAR, TRANSFORMERS
AND ALL FLOOR MOUNTED EQUIPMENT. PROVIDE FLEXIBLE
CONNECTION TO TRANSFORMERS AND SIMILAR EQUIPMENT PER
SPECIFICATIONS.
16 RECESS NEW DEVICES AND ASSOCIATED CONDUITS AND BACKBOX IN
EXISTING WALLS WHERE POSSIBLE. CUT AND PATCH AS REQUIRED.
1 FEED FROM GFI TYPE CIRCUIT BREAKER. LABEL RECEPTACLE COVER,
GFI PROTECTED.
2 FLOOR BOX SHALL BE WIREMOLD #EFB8S-OG PROVIDE WITH SIX
DUPLEX RECEPTACLES AND TWO DATA PLATES. PROVIDE DIVIDER AS
REQUIRED FOR ONE SIDE. PROVIDE TUNNEL AS REQUIRED. PROVIDE
WHITE DEVICES AND WHITE COVER PLATES AS REQUIRED. COVER
SHALL BE #EFB610BTCGY. PROVIDE ALL REQUIRED EQUIPMENT FOR A
COMPLETE INSTALLATION. COORDINATE FINAL LOCATION IN FIELD
WITH FURNITURE INSTALLER. PROVIDE (2) 11/4" CONDUITS TO
ACCESSIBLE CEILING FOR COMMUNICATIONS WIRING.
3 PROVIDE OUTLET BELOW SINK FOR AUTOMATIC FAUCET. COORDINATE
LOCATION WITH SINKS AND PIPING. CONNECT TO LOAD SIDE OF
ADJACENT GFI TYPE RECEPTACLE.
4 PROVIDE 120V CIRCUIT TO AUTOMATIC DOOR. CONCEAL ALL
CONDUIT WITHIN MULLION. NO CONDUIT SHALL BE EXPOSED.
PROVIDE 1" CONDUIT FROM DOOR CONTROL TO NEAREST ACCESSIBLE
CEILING FOR DATA WIRING.
ISSUED FOR DATE
ADDENDUM 1 10-02-2019
ADDENDUM 2 10-10-2019
M
HD HD
HD HD
JJ
J
J
JJ
J J J
PRJ
A/B/...
PRJ
A/B/...
M M
T
CR
CR
C R
C R
CR
CR
CR
CR
DC
D C
D C
DC
DC
D C
D C
D C
D C
E S
ES
E S
ES
E S
E S
E S
E
SDC
DC
DC
M M M
S S
S S
M
T.O.W.
110' - 0"
T.O.W.
110' - 0"
T.O.WALL
110' - 8"
T.O.WALL
110' - 8"
2" CONDUIT TO
DATA RACK
2" C.
COORDINATE DEVICE
LOCATIONS WITH
LAPTOP STAND.
MOUNT FLUSH INSIDE
ENCLOSURE.
2-GANG
DATA
FIRST FLOOR
100' - 0"
2" C.
1" C.
SPEAKER
PROVIDE SINGLE
GANG BOX.
TYPICAL
1" C.
18" X 18" X 6" NEMA 3R
HOFFMAN JUNCTION BOX
WITH HINGED COVER
CRESTRON AV
TOUCH SCREEN
3-GANG BOX
120V
/5
/3
P1
PANEL
SPD
8320V
480/277V
TX-PRI
GROUND BUS
10' SPACING (TYP)
WATER MAIN
#3/0 Cu GND (TYP)
10'-0"
GROUND ROD
CONTRACTOR TO TERMINATE
CONDUCTORS AT TRANSFORMER, UTILITY
METER TO BE INSTALLED ON
TRANSFORMER. COORDINATE WITH
UTILITY.
M
TO UTILITY POLE
145A
4 #600, 4" PVC
3 #1/0 15 kV 133%
PRIMARY W/CONCENTRIC
NEUTRAL, 4" PVC
24A
EXISTING
PANEL
P2
4 #1/0, 2" PVC
#3/0 Cu GND (TYP)
10'-0"
GROUND ROD PROVIDE NEW GROUND
ROD AND NEW BUILDING
GROUND BAR.
GROUND BUS
SERVICE
TRANSFORMER
GND.
TO BUILDING
STEEL
CONNECTIONS
TO GROUND MAT
NOTES:
1. ALL GROUNDING CONDUCTOR CONNECTIONS TO MAIN BUILDING GROUND BUS SHALL
BE EXOTHERMIC WELDED.
2. FOR QUANTITIES AND LOCATIONS AT STEEL COLUMNS, SEE FLOOR PLANS. FOR EACH
COLUMN CONNECTION, PROVIDE 1"C, 1#3/0 GROUND WIRE TO MAIN BUILDING BUS. (TYP.
FOR EVERY OTHER COLUMN @ PERIMETER)
3. ALL NEW TRANSFORMERS SHALL HAVE SEPARATE GROUND ROUTED BACK TO THE MAIN
SERVICE PANEL, BONDING TO NEARBY STEEL WILL NOT BE ACCEPTABLE.
TO MAIN
WATER PIPE
#3/0 GND. 1" C
TYPICAL
ELECTRICAL GROUND BUS
TO TRANSFORMER
GNDS.
IT GROUND BUS
120 VOLT
N
L
STARTER
MANUAL MOTOR
DISCONNECT
FAN BY DIV. 23
SWITCH W/
CONTACTS BY DIV. 23
OR TEMP. CONTROL
REVERSE ACT. STAT.
G FAN
#12
120V, 1Ø
208V, 3Ø
#10
FURNACE
CONDENSING
UNIT
MANUAL MOTOR
STARTER SWITCH
W/ LOCKOUT
6- #18
3- #18
T
30/3 NFDS
NEMA 3R
DOOR
CONTACTS
TO SECURITY CONTROL PANEL
CEILING
1/2" C
1" C
1" CONDUIT BETWEEN
WHERE LESS THAN 60"
REFER TO SECURITY DOOR
SCHEDULE FOR DEVICE
REQUIREMENTS AT EACH DOOR
3/4" FLEX CONDUIT TO BE RUN INSIDE
DOOR FRAMES TO STRIKEPLATE
3/4" CONDUIT
ELECTRIC STRIKE
RECESSED IN FRAME
CARD READER SINGLE GANG BOX
POWER SUPPLIES TO BE CENTRALLY LOCATED NEXT TO NEAREST
ACCESS CONTROL PANEL UNLESS OTHERWISE INDICATED.
REFER TO TECHNOLOGY PLAN FOR EXACT LOCATIONS.
SEAL ALL CONDUITS THROUGH CEILING
CORNER BRACKET
AND FASTENERS
EXTERIOR PENETRATION SHALL
BE CONCEALED BY MOUNTING
BRACKET. RUN 1" CONDUIT
BACK TO IT RACK.
3/4" LIQUID TIGHT CONDUIT
SHALL BE RUN FROM INTERIOR
MOUNTED SG BACKBOX
THROUGH PENETRATION TO
CAMERA MOUNTING BRACKET.
CAMERA MOUNTING
BRACKET
REFER TO FLOOR PLAN OR
CAMERA SCHEDULE FOR
ELEVATION REQUIREMENTS.
CEILING
EXTERIOR CORNER MOUNT CAMERAS
P1
BUILDING
GROUND BAR
TX-P1
10' GROUND
ROD (TYPICAL)
WH-1
F-3
F-2
F-1
ACCU-1 ACCU-2 ACCU-3
STORAGE
HOME LOCKER
ROOM
VISITOR
LOCKER ROOM
TRAINING
STORAGE
TLT
OFFICIALS
WOMENS
RESTROOMS
J.C./MECH.
MENS
RESTROOMS
CONCESSIONS
ELEC/IT
P1- 6
GFI
P1- 7
GFI
P1- 8
GFIP1- 9
GFI
P1- 10
GFI
P1- 11
GFI
P1- 12
GFI
P1- 13
GFI
P1- 14
GFIP1- 15 P1- 16
P1- 4
P1- 3 P1- 2
P1- 5
P1- 5
P1- 5
P1- 5
P1- 33
P1- 17
P1- 18
GFI
P1- 18
GFI
2 2
2 2
P1- 19
GFI
P1- 19
GFI
P1- 19
GFI
P1- 19
GFI
P1- 19
GFI
P1- 21
P1- 20
P1- 19
P1- 22 P1- 23
P1- 26
GFI
P1- 25P1- 24
P1- 27
GFI
P1- 27 P1- 27
P1- 27
P1- 27 P1- 27
P1- 31
P1- 60 P1- 31
P1- 60
P1- 31
P1- 33
P1- 33
P1- 62P1- 62
P1- 37
GFI
P1- 30
GFI
P1- 30
GFI
P1- 32
GFI
P1- 32
GFI
P1- 32
GFI
P1- 35
P1- 34
WP
P1- 34
WP
P1- 34
WP
P1- 29
WP
P1- 29
WP
P1- 28
WP
P1- 28
WP
P1- 47,49P1- 43,45P1- 39,41
E 101
W
W
P1- 26
GFI
P1- 48P1- 44 P1- 46
P1- 7
GFI
P1- 8
GFI
P1- 50
GFI
P1- 1
GFIP1- 14
GFI
P1- 52
GFI
P1- 51
GFI
#3/0 GND. WIRE
(TYPICAL)
IT GROUND BAR
4'x8' FIRE RATED
PLYWOOD
WALL MOUNTED
PHONE
WALL MOUNTED
PHONE
WALL MOUNTED
PHONE
UTILITY PAD
P1- 31
GFI
P1- 33
GFI
19' - 0"
W
W
60/2 NEMA 3R NFD
TYPICAL OF 3
#6 WIRE, 1" C.
P1- 56
GFI
WALL MOUNTED
PHONE
CP-1
P1- 53
EF-1 EF-2 EF-3P1- 46
WP
P1- 28
FEED FROM LOAD
SIDE OF GFI OUTLET
E a s t K a la m a z o o A v e n u e S u it e
K a la m a z o o M ic h ig a n
-5
.3
.6
P H
O
.3
.6
F A
X
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
E a s t
F u lt o n S tr e e t, S u it e
G ra n d R a p id s M ic h ig a n
.4
.9
P H
O N
E
.4
.5
F A
X
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
P O
W E
R P
L A
N
-1
.4
E
M A
Y
A T
H L E
T
IC
T E
A M
R O
O M
M a tt a w a n M
I
M A
T T
A W
A N
C O
N S
O L
ID
A T
E D
S C
H O
O L S
GENERAL ELECTRICAL NOTES
ELECTRICAL KEYED NOTES
1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING
AND PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE
REMOVED AND NOT REPLACED.
2 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED
EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH
EQUIPMENT, ADJUST CIRCUIT SIZE AS REQUIRED.
3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.
4 REFER TO INTERIOR ELEVATIONS, SECTIONS, ARCHITECTURAL
ELEVATIONS AND RELATED DRAWINGS FOR EXACT DEVICE LOCATIONS
AND MOUNTING HEIGHTS. WHERE DEVICES ARE MOUNTED UNDER OR
ABOVE TACK BOARDS, DOORS, WINDOWS, OR ANY PIECE OF
EQUIPMENT, THE ELECTRICAL DEVICE SHALL BE CENTERED AS SHOWN.
COORDINATE LOCATION OF FURNITURE CONNECTIONS AND/OR
RECEPTACLES AND DATA RACEWAYS WITH APPROVED FURNITURE
SHOP DRAWINGS, FINAL CONNECTIONS TO FURNITURE BY ELECTRICAL
CONTRACTOR.
5 SEAL ALL CONDUITS PENETRATING ATTIC SPACE TO ENSURE NO AIR
TRANSFER.
6 HOME RUN ALL DATA CONDUITS BACK TO IT RACK. LABEL EACH
CONDUIT AND DEVICE. CONSOLIDATE ALL SECURITY CONDUITS BY
TYPE, I.E. CAMERA CONDUITS AND DOOR SECURITY CONDUITS.
7 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.
PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT
AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED
ON EXTERIOR OF BUILDING.
8 PROVIDE 4" HOUSEKEEPING PADS FOR TRANSFORMER. PROVIDE
FLEXIBLE CONNECTION TO TRANSFORMERS AND SIMILAR EQUIPMENT
PER SPECIFICATIONS.
1 PROVIDE 1" CONDUIT FROM DOOR CONTACT BACK TO IT RACK.
2 PROVIDE ROUGH IN FOR AUTOMATIC FLUSH VALVE. COORDINATE
LOCATION WITH SHOP DRAWING. THERE SHALL BE NO EXPOSED
CONDUIT OR JUNCTION BOX. PROVIDE ALL REQUIRED LOW VOLTAGE
WIRING BETWEEN VALVE AND TRANSFORMER.
3 FEED FROM GFI TYPE CIRCUIT BREAKER. LABEL DEVICE ON COVER
PLATE.
4 PROVIDE 2-GANG FLUSH MOUNTED BACKBOX AND 1" CONDUIT BACK
TO DATA RACK FOR WIRELESS ACCESS POINT.
5 PROVIDE WEATHER PROOF ENCLOSURE IN ATTIC SPACE WITH 1"
CONDUIT HOME RUN BACK TO IT RACK. REFER TO DETAIL
6 PROVIDE 1" CONDUIT TO IT RACK FOR CAMERA.
7 PROVIDE WALL MOUNTED LOCKING DESK. GLOBAL INDUSTRIAL
#WB249997. PROVIDE POWER AND DATA DEVICE CENTER INSIDE.
DEVICES SHALL BE FLUSH MONTED IN WALL AND FLUSH INSIDE THE
CABINET. MODIFY BACK OF CABINET AS REQUIRED FOR JUNCTION
BOXES.
1/4" = 1'-0"E 101
2 TYPICAL LOCKER ROOM ELEVATIONNOTES:
HAND DRYER - 3600 VA 100.00% 3600 VA
TECHNOLOGY - 720 VA 100.00% 720 VA
RECEPTACLE - 12060 VA 91.46% 11030 VA TOTAL ESTIMATED DEMAND... 118 A
POWER - 23222 VA 100.00% 23222 VA TOTAL CONNECTED LOAD (A): 121 A
Other 568 VA 100.00% 568 VA TOTAL ESTIMATED DEMAND: 42536 VA
LIGHTING - 3396 VA 100.00% 3396 VA TOTAL CONNECTED LOAD: 43566 VA
HVAC - 0 VA 0.00% 0 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
TOTAL AMPS: 154 A 102 A 109 A
TOTAL LOAD: 18419 VA 12194 VA 12953 VA
83 SPARE 20 1 0 0 1 20 SPARE 84
81 SPARE 20 1 0 0 1 20 SPARE 82
79 SPARE 20 1 0 0 1 20 SPARE 80
77 SPARE 20 1 0 0 1 20 SPARE 78
75 SPARE 20 1 0 0 1 20 SPARE 76
73 SPARE 20 1 0 0 1 20 SPARE 74
71 SPARE 20 1 0 0 1 20 SPARE 72
69 SPARE 20 1 0 0 1 20 SPARE 70
67 SPARE 20 1 0 0 1 20 SPARE 68
65 SPARE 20 1 0 0 1 20 SPARE 66
63 -- -- -- 0 0 1 20 SPARE 64
61 -- -- -- 0 540 1 20 62
59 PUMP HOUSE PANEL P2 100 3 0 540 1 20 60
57 SPARE 20 1 0 0 1 20 SPARE 58
55 180 1 20 RECEPTACLE - 56
53 HVAC - 20 1 0 436 1 20 Other 54
51 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 52
49 -- -- -- 3037 180 1 20 RECEPTACLE - 50
47 POWER - ACCU-3 20 2 3037 0 1 20 HVAC - EF-3 48
45 -- -- -- 3037 180 1 20 HVAC - EF-2 46
43 POWER - ACCU-2 20 2 3037 0 1 20 HVAC - EF-1 44
41 -- -- -- 3037 538 1 20 LIGHTING - 42
39 POWER - ACCU-1 20 2 3037 720 1 20 LIGHTING - 40
37 RECEPTACLE - 20 1 180 1225 1 20 LIGHTING - 38
35 RECEPTACLE - 20 1 180 1045 1 20 LIGHTING - 36
33 RECEPTACLE - 20 1 720 540 1 20 RECEPTACLE - 34
31 RECEPTACLE - 20 1 720 540 1 20 RECEPTACLE - 32
29 RECEPTACLE - 20 1 360 360 1 20 RECEPTACLE - 30
27 RECEPTACLE - 20 1 1080 540 1 20 RECEPTACLE - 28
25 HAND DRYER - 20 1 900 360 1 20 RECEPTACLE - 26
23 HAND DRYER - 20 1 900 900 1 20 HAND DRYER - 24
21 HVAC - F-2 20 1 0 900 1 20 HAND DRYER - 22
19 RECEPTACLE - 20 1 5900 0 1 20 HVAC - F-1 20
17 HVAC - F-3 20 1 0 360 1 20 RECEPTACLE - 18
15 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 16
13 RECEPTACLE - 20 1 180 360 1 20 RECEPTACLE - 14
11 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 12
9 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 10
7 RECEPTACLE - 20 1 360 360 1 20 RECEPTACLE - 8
5 RECEPTACLE - 20 1 720 180 1 20 RECEPTACLE - 6
3 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 4
1 RECEPTACLE - 20 1 180 180 1 20 RECEPTACLE - 2
CIRCUIT DESCRIPTION
TRIP
(A) POLES A B C POLES
TRIP
(A) CIRCUIT DESCRIPTION
ADDED ACCESSORIES: SPD I.C. RATING: 35,000
LOCATION: FIRST FLOOR AMPS: 400 A MB , ULSE RATED FED FROM: TX-P1
PANEL: P1 MOUNTING: SURFACE VOLTAGE: 208/120V, 3PH, 4W
PANELBOARD "P1" LOAD SCHEDULE
SCALE: NONE
ONE LINE
SCALE: NONE
BUILDING GROUND DETAIL
SCALE: NONE
EXHAUST FAN CONTROL
SCALE: NONE
FURNACE/CONDENSING UNIT
SCALE: NONE
TYPICAL SECURITY DOOR DETAIL
SCALE: NONE
EXTERIOR CORNER MOUNT CAMERA
1/4" = 1'-0"
POWER PLAN
ISSUED FOR DATE
Tony Nuismer
TS
Tony Nuismer
Tony Nuismer
File details come from the government source that posted it. Updated .