This document is the OPSR 3 – OBO Project Requirements for FY26, specifically Section J.2.3 on Signage (OPR 12), issued October 1, 2025, by the U.S. Department of State's Overseas Buildings Operations division. The document establishes comprehensive graphic standards for embassy signage and wayfinding systems.

The standards define a standardized color palette with eight primary colors identified by designation codes (C1–C4, C10–C11, C20–C21) and three finish types (F1–F3), all with corresponding specifications in multiple color systems including Matthews Paint, Pantone PMS, 3M Scotchcal films, and 3M Scotchlite reflective films to ensure consistency across fabrication methods. Typography standards specify Calibre Regular and Medium typefaces (available from Klim Type Foundry) and Arial Regular, Italic, and Bold (from Monotype Type Foundry), with defined tracking parameters to optimize readability. The document provides a comprehensive symbols library including amenity icons, standard and emergency regulatory symbols, directional arrows, seal graphics, and extensive warning symbols covering hazards such as fire, electrical, chemical, and mechanical dangers. Two representative sign components are detailed: SF02 (Directional, Wall-mounted) designed for interior wayfinding with bilingual capabilities, and SR02 (Alert, Large) for emergency and regulatory information, both with dimensional specifications, material requirements, installation elevations, and graphic layout variations. A deviation process is established requiring architect or designer submissions to the Contracting Officer Representative for approval when standard colors or finishes conflict with specific architectural environments, with separate coordination permitted for exterior and interior conditions.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OPSR 3 – OBO PROJECT REQUIREMENTS | FY26

J.2.3

Signage

OPR 12

FY26

October 1, 2025

UNCLASSIFIED

UNCLASSIFIED

Extract

Graphic Standards

Description Page

Paint and Silkscreen Direct Print Adhesive Films

Color No.

Project Color Name Used Where Matthews Paint Match Pantone PMS

Opaque 3M™ Scotchcal™ ElectroCut™ Graphic Film Series 7725

Reflective 3M™ Scotchlite™ Reflective Graphic Film Series 680

C1 Accent Gray Accent border on pylons and signs

MP18249

Dark Pewter Metallic

Warm Gray 11 C

Petrolium Blue Metallic 247

N/A

C2 Secondary Gray Background seal, Direct print match for translations

MP18149

Dark Nickel Metallic

Warm Gray 9 C

Slate Metallic 201 N/A

C3 Regulatory Red Border and symbols on regulatory signs

MP10252

Campbells Soup Red

1805 C Geranium 63 Ruby Red 82

C4 Warning Yellow Border and symbols on warning signs

MP10211

Citrus Yellow

116 C Bright Yellow 15 Yellow 71

C10 Text Black Primary text color on all signs

MP40821

Draconia

Black 3 C Black 12 N/A

C11 Text Bronze Text color on bronze plaques

MP04418

Doric Brown

7533 C N/A N/A

C20 Background White

Background color on interior signs

MP32071

White Wonder

White White 10 White 10

C21 Background Silver

Background color on exterior pylon and plaque signs

MP18091

Silverstone Metallic

Warm Gray 2 C

Satin Aluminum 120 N/A

Finish Number

Project Color Name Used Where Finish

F1 Aluminum Embassy ID Light Horizontal Satin

F2 Bronze Dedication Plaques, Embassy ID Statuary Bronze

F3 Stainless Steel Dedication Plaques, Embassy ID Light Horizontal Satin

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

Paint systems indicated are for color match reference purposes only. Paint required for fabrication, including paint for backgrounds, lettering, screened copy, subsurface copy, etc., shall be compatible with the materials and to which it is applied. Finishes, materials, fabrication methods shall be appropriate for the environmental conditions in which the signage is installed.

All paint colors to have a satin non-glare finish in compliance with ABA 703.5.1 Finish and Contrast.

Color

EMBASSY OF THE

UNITED STATES

OF AMERICA

Embajada de Los Estados Unidos de América

Embajada de Los Estados Unidos de América

Sección de Asuntos Consulares

EMBASSY OF

THE UNITED STATES

OF AMERICA

CONSULAR AFFAIRS

SECTION

Amenity Translation Placement Here

Amenity Name Placement Here

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus

STAFF PARKING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus lobortis euismod.

Workroom Sala de trabajo

506B RESTROOM

204A

IN CASE OF FIRE, ELEVATORS

ARE OUT OF SERVICE. USE EXIT STAIRS.

EN CASO DE INCENDIO, LOS ASCENSORES

ESTÁN FUERA DE SERVICIO.

USAR ESCALERAS DE SALIDA.

Workroom Sala de trabajo

506B RESTROOM

204A

IN CASE OF FIRE, ELEVATORS

ARE OUT OF SERVICE. USE EXIT STAIRS.

EN CASO DE INCENDIO, LOS ASCENSORES

ESTÁN FUERA DE SERVICIO.

USAR ESCALERAS DE SALIDA.

Embajada de Los Estados Unidos de América

Sección de Asuntos Consulares

EMBASSY OF

THE UNITED STATES

OF AMERICA

CONSULAR AFFAIRS

SECTION

Amenity Translation Placement Here

Amenity Name Placement Here

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus

STAFF PARKING

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus lobortis euismod.

EMBASSY OF THE

UNITED STATES

OF AMERICA

Embajada de Los Estados Unidos de América

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

ARCHITECTURAL COLORS AND FINISHES

The colors and finishes indicated within these Standards have been selected to complement a wide range of architectural contexts. They are provided as the basis for all standard signage and are consistent from one post to another. Using the standard palette of colors assures that any supplier can fabricate these signs without any additional information, reducing the possibility for future coordination errors.

The color table, on the previous page, identifies each color or finish by a number. Each color is then defined in multiple color-systems to ensure consistency despite varying construction processes. Whether a fabricator utilizes silkscreen or direct print, the standards define an appropriate color system, allowing them to construct a consistent sign without ad hoc changes to the specifications.

Understanding that one solution may not be appropriate for all posts’ architectural finishes and materials, standard signage designs may need to be modified. Where conflicts occur and deviations are required to ensure signage adequately integrates into diverse environments, the COR (Contracting Officer

Representative) shall follow the Process for Deviations. Each variation to color or finish should be fully documented for each applicable color system for future implementations.

PROCESS FOR DEVIATIONS

1 The architect or designer proposes a change with a submission to the COR (Contracting Officer Representative).

A For the design phase, the COR will be the Project Manager

B For the construction phase, the COR will be the Project Director

2 COR reviews submission in conjunction with the design subject matter expert (architect, designer, landscape architect, engineer, etc.) and will either approve, comment, or reject requested deviation based on its impact.

3 Architect or designer resubmits and COR reviews as necessary to find a resolution.

INTERIOR SIGNAGEEXTERIOR SIGNAGE

STANDARDS

NEUTRAL PALETTE

SAMPLE

BRONZE-TONE

ARCHITECTURAL

DEVIATION

NOTE

The exterior and interior conditions should be considered independently and may require a separate coordination effort to align with their particular architectural finishes.

Color (continued)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

Calibre Regular (Klim Type Foundry)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

Calibre Medium (Klim Type Foundry)

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

NOTE

The Calibre typeface is available for purchase from the Klim Type Foundry:

https://klim.co.nz/retail-fonts/calibre/

The term "Tracking" used throughout the Standards refers to uniformly increasing or decreasing the horizontal spacing between a range of typographic characters to adjust the overall letterspacing. Tracking is utilized to improve the readability of type, especially of bold type weights or type set in all-caps.

TRACKING

Tracking: 0

TRACKING

Tracking: +50

TR ACKING

Tracking: +100

Typography

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

Arial Regular (Monotype Type Foundry)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

Arial Italic (Monotype Type Foundry)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

Arial Bold (Monotype Type Foundry)

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

NOTE

The Arial typeface is available for purchase from the Monotype Type Foundry:

http://www.fontshop.com/fonts/family/arial/

Typography (continued)

Amenity

Standard Regulatory

Emergency Regulatory

Directional Seal Wail SoundHigh-Low Tone Fire Bell AlarmRapid Intermittent

Alarm Hi-Low AlarmStutter Alarm Soft Gong Alarm

No Cell PhonesNo Smoking No CamerasNo Wearables No LaptopsNo Audio Devices Egress Star Star Of LifeNo Food

Women’s RestroomUnisex Restroom AccessibleMen’s Restroom CashierStairs Parking

Black Seal Without Text

Arrow Up Arrow RightArrow DownArrow Left Cropped Seal

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

NOTE

Refer to the U.S. Department of State Brand System website for seal artwork. Do not scan or utilize the image in the OPSR.

https://brand.america.gov/d/DaSsgMXWCWUP/ our-brand#/visual-elements/the-seal

Symbols

UNCLASSIFIED

UNCLASSIFIED

https://brand.america.gov/d/DaSsgMXWCWUP/our-brand#/visual-elements/the-seal https://brand.america.gov/d/DaSsgMXWCWUP/our-brand#/visual-elements/the-seal

Cut / Sever Rotating Blade / Saw

UV LightFire, Flammable Cut / Sever / Shear Sharp Blade

Fall OxidizerCut / Sever Rotating Blade / Screw

Low Object: Head Hazard

Cut / Puncture Sharp Blade / Point

Lift Hazard Heavy Object

Pinch Rollers Skin Puncture Pressurized Air /

Water Jet

Automatic Start-upBurn Hazard Hot Surface

Pinch / Entanglement / Crush Gears

Tip Over Hazard Corrosive

General Danger Non-Ionizing Radiation Radio

Frequency Energy

Trip Pinch / Entanglement Gear / Chain Drive

Crush / Impact Hazard Foot

Laser LED Radiation Slip Crush / Impact Moving Parts Can

Crush & Cut

Explosion Arc Flash

Forklift

Pinch / Entanglement Roller Belt Drive /

Shear Point

Voltage, Body Shock, Electrocution Electric

Shock or Burn

Voltage Hazard, Electrocution Electric

Shock or Burn

Inhalation Hazard Hazardous Liquid

Voltage, Hazard Shock, Electrocution Electric

Shock or Burn

Voltage Hazard Shock in the Box

Voltage Hazard Electric Meter Shock

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

Symbols

Warning Symbols (1 of 3)

Do Not Remove PlugDo Not Turn Off (Button)

Do Not Switch Do Not Enter, Confined Space

No DiggingNo Welding No Digging Underground

Electrical Cable

Do Not Drink WaterNo Food of Drink No Dumping (Drain) Overhead Power Lines

Do Not Enter No Entry

Do Not Enter No Access for Unauthorized Persons

Eye Wash Wash HandsSafety Shower First Aid Station Fire ExtinguisherFirst Aid Kit Fire Ax Fire Hydrant Fire Plug

Fire Hose

Do Not Smoke No Smoking

Fire DoorFire Alarm Fire Exit (Right)Fire Exit (Left) Use Stairs In Case of Fire

Confined Space Watch For Oncoming Traffic

Needle Disposal Deposit Syringes Here

No Open Flames

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

Symbols

Warning Symbols (2 of 3)

Flammable Materials Gas

Flammable Materials Oxygen

Non-Flammable Materials

Gas

Flammable Liquid Flammable Liquid Fuel Oil

Oxidizer Harmful, Stow Away from Foodstuffs

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2

Symbols

Warning Symbols (3 of 3)

SF02

Sign Type Description Page

Mail Room Sala de Correo

Travel Section Sección de Viajes

Cafetería Cafeteria

Health Unit Unidad de Salud

Community Liaison O�ice Oficina de Enlace de la Comunidad

C - Side View Scale: 1 1/2"=1'-0" (1:8)

A - Front View Scale: 1 1/2"=1'-0" (1:8)

B - Plan View Scale: 1 1/2"=1'-0" (1:8)

D

D - Side View Detail Scale: 6"=1'-0" (1:2)

1'-

5/ 8"

(6 m m)

2'- 7 1

/4

(7 m m)

1'-3 3/4" (400 mm)

1'-5 1/4" (438 mm)

3/16" (5 mm)

1/4" (7 mm)

1/2" (13 mm)

3/4" (19 mm)

2" O

C T

YP

(5 1 m m)

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 6 • Find SEPTEMBER 2024 VERSION 2.2

SF02

Directional, Wall-mounted Component 1 of 3

DESCRIPTION

1 1/4" (7 mm) thick painted aluminum Border Panel with frisket painted Cropped Seal Symbol Border Panel Color: C1 Cropped Seal Symbol Color: C2

2 1/2" (13 mm) thick painted aluminum Face Panel with direct printed Directional Symbols, Text (English), Text (Translation), and Horizontal Rule;

mounted to Border Panel Face panel Color: C20 Directional Symbols Color: C10 Text (English) Color: C10 Text (Translation) Color: C2 Horizontal Rule Color: C10

3 3/16" (5 mm) thick painted Standoff Collar Standoff Collar Color: C20

4Wall
5Fully concealed mechanical fastener

NOTES

• Final material, finish, size, fabrication, mounting method, and placement to be approved by

OBO.

UNCLASSIFIED

UNCLASSIFIED

RideauPT Text Box or C99

Mail Room Sala de Correo

Travel Section Sección de Viajes

A - Graphic Layout, Example 1 Scale: 1 1/2"=1'-0" (1:8)

Community Liaison O�ice Oficina de Enlace de la Comunidad

Cafetería Cafeteria

Health Unit Unidad de Salud

B - Graphic Layout, Example 2 Scale: 1 1/2"=1'-0" (1:8)

LEVEL 3

Mail Room Sala de Correo

Travel Section Sección de Viajes

Community Liaison O�ice Oficina de Enlace de la Comunidad

Cafetería Cafeteria

Health Unit Unidad de Salud

Information System Central Sistema de Información Central

Other Message Here Otro mensaje aqui

Other Message Here Otro mensaje aqui

1 9/16" (39 mm)

1 1/16" (26 mm)

1 1/2" (38 mm)

1 1/16" MIN

(27 mm)

1'-3 3/4" (399 mm)

1'-2 1/8" (359 mm)

1'- 4 1

/4

(4 m m)

7 5 /8

(1 m

m) 2 1

/8

(5 4 m

m) 1 1

/2

(3 8 m m)

5/ 8"

(1 6 m m)

5/ 8"

(1 6 m

m) 5/

(9 m

m) 1"

(2 5 m

m) 1"

(2 5 m m)

1/

(2 m m)

1" (2

5 m m)

1 9/16" (39 mm)

1 1/16" (26 mm)

1 1/16" MIN

(27 mm)

1'-3 3/4" (399 mm)

1'-2 1/8" (359 mm)

1'- 4 1

/4

(4 m m)

2 1 /8

(5

4 m m)7/

8" (2

2 m m)

1 5 /1

6" (3

4 m m)

5/ 8"

(1 6 m

m) 5/

(7 m m)

1" (2

5 m m)

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 6 • Find SEPTEMBER 2024 VERSION 2.2

SF02

Directional, Wall-mounted Component 2 of 3

DESCRIPTION

1Cropped Seal Symbol: Symbols (page 22)
2Directional Symbols: Symbols (page 22)
3Typeface: Calibre Regular, Tracking: 0
4Horizontal Rule
5Typeface: Calibre Medium, Tracking: 0

NOTES

• Directional Symbols and Text shown for graphic layout; OBO to approve final content.

• Include translation only if sign is located in front of the hard line and accessible by the general public.

A - Installation Elevation Scale: 1/2"=1'-0" (1:24)

Mail Room Sala de Correo

Travel Section Sección de Viajes

Cafetería Cafeteria

Health Unit Unidad de Salud

Community Liaison O�ice Oficina de Enlace de la Comunidad

4'- 0"

(1 cm

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 6 • Find SEPTEMBER 2024 VERSION 2.2

SF02

Directional, Wall-mounted Component 3 of 3

NOTES

• Sign to be installed level and plumb. Contractor to coordinate with architect/OBO to ensure installation will accommodate setting and wall conditions.

SR 02

Sign Type Description Page

A - Front View Scale: 3"=1'-0" (1:4)

C - Side View Scale: 3"=1'-0" (1:4)

B - Plan View Scale: 3"=1'-0" (1:4)

D

English messages that have a large character count should be placed here above the translation below.

Los mensajes en inglés que tienen un gran número de caracteres deben colocarse aquí arriba de la traducción a continuación.

D - Side View Detail Full Scale (1:1)

9" (229 mm)

1'- 3 3

/4

(4 m m)

1" O

C T

YP

(2 5 m m)

1/8" (3 mm)

1/8" (3 mm)

1/4" (6 mm)

3/8" (10 mm)

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2

SR02

Alert, Large Component 1 of 5

DESCRIPTION

1 1/8" (3 mm) thick painted acrylic Border Panel Border Panel Color: C3 or C4

2 1/4" (6 mm) thick painted acrylic Face Panel;

mounted to Border Panel Face Panel Color: C20

3 Direct printed Text (English) Text (English) Color: C10

4 Direct printed Text (Translation) Text (Translation) Color: C2

5 1/8" (3 mm) thick painted Standoff Collar Standoff Collar Color: C20

6Wall
7Fully concealed mechanical fastener

NOTES

• Final material, finish, size, fabrication, mounting method, and placement to be approved by

OBO.

Regulatory

SR.1

Warning

SR.2

Explanatory

SR.3

Duis mollis, est non nisi erat porttitor odio sem nec elit.

Duis mollis, est non nisi erat porttitor odio sem nec elit.

Duis mollis, est non nisi erat porttitor odio sem nec elit.

Duis mollis, est non nisi erat porttitor odio sem nec elit.

Duis mollis, est non nisi erat porttitor odio sem nec elit.

Duis mollis, est non nisi erat porttitor odio sem nec elit.

For more about sign classifications, refer to Sign Selection & Placement Guide Alert (page 13)

Fire:

Fire Bell Alarm

• Obey All Verbal Instructions Via P.A. System

• Secure Classified And Controlled Material

• Close All Windows And Doors

• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator

• Assemble In Rear Garden Area Or As Instructed

Bomb: Stutter Alarm (Rapid Intermittent)

• Obey All Verbal Instructions Via P.A. System

• Check WorzUnusual Items

• If Noted, Report Immediately To Post One

• Secure Classified And Controlled Material

• Open All Doors And Windows

• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator

• Proceed To Upper Garden Area Or As Instructed

Imminent Terrorist Attack:

Hi-lo Alarm (Alternating)

• Possible Attack In Front Of Embassy

• Do Not Secure Classified Material

• Remover Yourself From The Danger Area

(Front Windows, Front Facade Of The Building)

• Move To Back Rear Of The Building Towards Garden Area

• Await Further Verbal Instructions Over P.A. System

All Clear: Soft Gong Alarm

• Resume Normal Operations

Emergency Alarm Signals

All Electronics Prohibited Beyond This Point

Toda Las Electrónicas Prohibida Después de Este Punto

No Cell Phones No Celulares

No Recording Devices Sin Dispositivo de Grabación

No Wearables No Usablez

No Audio Devices No Dispositivos de Audio

No Laptops No Computadoras Portátiles

B - Example 2, SR2.1 Scale: 1 1/2"=1'-0" (1:8)

Emergency Alarm Tones

HIGH-LOW TONE: Police (Duck and Cover)

• Run Away From All Windows

• Duck Under Furniture

• Await Further Instructions

WAIL SOUND: Ambulance (Evacuate)

• Secure All Classified

• Close All Windows and Doors

• Do Not Lock Doors

• Evacuate Building Using the Nearest Emergency Exit

• Assemble in Designated Area for Further Instructions

RAPID INTERMITTENT HORN: Stutter (Safe Areas)

• Move To The Safe Areas

• Await Further Instructions

C - Example 3, SR2.1 Scale: 1 1/2"=1'-0" (1:8)

D - Example 4, SR2.1 Scale: 1 1/2"=1'-0" (1:8)

If you have a pacemaker or other internal medical device, please tell the security o�icer.

Si tiene un marcapasos u otro dispositivo médico interno, por favor, dígale al oficial de seguridad.

A - Example 1, SR2.1 Scale: 1 1/2"=1'-0" (1:8)

E - Example 5, SR2.2 Scale: 1 1/2"=1'-0" (1:8)

Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.

Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado negativo.

F - Example 5, SR2.3 Scale: 1 1/2"=1'-0" (1:8)

Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.

Etiam porta sem malesuada.

Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado negativo Etiam porta sem.

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2

SR02

Alert, Large Component 2 of 5

NOTES

• Signs may contain regulatory or warning information. For more about sign classifications, refer to Sign Selection & Placement Guide Alert (page 13).

English messages that have a large character count should be placed here above the translation below.

Los mensajes en inglés que tienen un gran número de caracteres deben colocarse aquí arriba de la traducción a continuación.

A - Graphic Layout 1 Scale: 6"=1'-0" (1:2)

3/4" (19 mm)

9/16" (14 mm)

9/16" MIN.

(14 mm)

3/ 4"

(1 9 m

m) 1"

(2 5 m

m) 1/

2" (1

3 m m)

5/

(8 m m)

/1

6" (2

1 m m)

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2

SR02

Alert, Large Component 3 of 5

DESCRIPTION

1 Typeface: Calibre Regular, Tracking: 0

NOTES

• Text shown for graphic layout; OBO to approve final content.

• Include translation only if sign is located in front of the hard line and accessible by the general public.

A - Graphic Layout Scale: 6"=1'-0" (1:2)

Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.

Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado

B - Graphic Layout 2 Scale: 6"=1'-0" (1:2)

5" (128 mm)

3/4" (19 mm)

9/16" (14 mm)

9/16" MIN.

(14 mm)

3/ 4"

(1 9 m

m) 1/

2" (1

3 m m)

5/

(8 m m)

/1

6" (2

1 m m)

3/ 4"

(1 9 m

m) 1 7

/8

(4 8 m

m) 9/

(1 4 m m)

/1 6"

(2 1 m

m) 1 15/16" (48 mm)

3/8" (9 mm)

ALIGN TO ARCHITECTURAL

ELEMENTS OR LIGHTING

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2

SR02

Alert, Large Component 4 of 5

DESCRIPTION

1 Regulatory or Warning Symbols:Symbols (page 22)

2 Typeface: Calibre Regular, Tracking: 0

NOTES

• Text shown for graphic layout; OBO to approve final content.

• Include translation only if sign is located in front of the hard line and accessible by the general public.

Fire:

Fire Bell Alarm

• Obey All Verbal Instructions Via P.A. System

• Secure Classified And Controlled Material

• Close All Windows And Doors

• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator

• Assemble In Rear Garden Area Or As Instructed

Bomb: Stutter Alarm (Rapid Intermittent)

• Obey All Verbal Instructions Via P.A. System

• Check WorzUnusual Items

• If Noted, Report Immediately To Post One

• Secure Classified And Controlled Material

• Open All Doors And Windows

• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator

• Proceed To Upper Garden Area Or As Instructed

Imminent Terrorist Attack:

Hi-lo Alarm (Alternating)

• Possible Attack In Front Of Embassy

• Do Not Secure Classified Material

• Remover Yourself From The Danger Area

(Front Windows, Front Facade Of The Building)

• Move To Back Rear Of The Building Towards Garden Area

• Await Further Verbal Instructions Over P.A. System

All Clear: Soft Gong Alarm

• Resume Normal Operations

Emergency Alarm Signals

Fire:

Fire Bell Alarm

• Obey All Verbal Instructions Via P.A. System

• Secure Classified And Controlled Material

• Close All Windows And Doors

• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator

• Assemble In Rear Garden Area Or As Instructed

Bomb: Stutter Alarm (Rapid Intermittent)

• Obey All Verbal Instructions Via P.A. System

• Check WorzUnusual Items

• If Noted, Report Immediately To Post One

• Secure Classified And Controlled Material

• Open All Doors And Windows

• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator

• Proceed To Upper Garden Area Or As Instructed

Imminent Terrorist Attack:

Hi-lo Alarm (Alternating)

• Possible Attack In Front Of Embassy

• Do Not Secure Classified Material

• Remover Yourself From The Danger Area

(Front Windows, Front Facade Of The Building)

• Move To Back Rear Of The Building Towards Garden Area

• Await Further Verbal Instructions Over P.A. System

All Clear: Soft Gong Alarm

• Resume Normal Operations

Emergency Alarm Signals

Workroom Sala de Trabajo

506B

All Electronics Prohibited Beyond This Point

Toda Las Electrónicas Prohibida Después de Este Punto

No Cell Phones No Celulares

No Recording Devices Sin Dispositivo de Grabación

No Wearables No Usablez

No Audio Devices No Dispositivos de Audio

No Laptops No Computadoras Portátiles

All Electronics Prohibited Beyond This Point

Toda Las Electrónicas Prohibida Después de Este Punto

No Cell Phones No Celulares

No Recording Devices Sin Dispositivo de Grabación

No Wearables No Usablez

No Audio Devices No Dispositivos de Audio

No Laptops No Computadoras Portátiles

A - Installation Elevation Scale: 3/8"=1'-0" (1:32)

B - Installation Elevation Scale: 3/8"=1'-0" (1:32)

C - Installation Elevation Scale: 3/8"=1'-0" (1:32)

D - Installation Elevation Scale: 3/8"=1'-0" (1:32)

If you have a pacemaker or other internal medical device, please tell the security o�icer.

Si tiene un marcapasos u otro dispositivo médico interno, por favor, dígale al oficial de seguridad.

Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.

Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado

4'- 6"

(1 ,37

2 m m)

5" (128 mm)

4'- 6"

(1 ,37

2 m m)

5" (128 mm)

4'- 6"

(1 ,37

2 m m)

4'- 6"

(1 ,37

2 m m)

3/4" (19 mm)

5" (128 mm)

5" (128 mm)

ALIGN

ALIGN TO ARCHITECTURAL

ELEMENTS OR LIGHTING

OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2

SR02

Alert, Large Component 5 of 5

NOTES

• Sign to be installed level and plumb. Contractor to coordinate with architect/OBO to ensure installation will accommodate setting and wall conditions.

OPR 12 SIGNAGE
Table of Contents
Introduction
1 Overview
2 Signage & Wayfinding Design Standards
3 Enclosure OBO Project Standard Requirements Signage & Wayfinding Design Standards
Table of Contents
Introduction
Section 1 • Signage Guidelines
Sign Selection & Placement Guide
Room Numbering Strategies
Code Reference
Section 2 • Graphic Standards
Color
Typography
Symbols
Section 3 • Sign Type Overview
Sign Type Overview
Section 4 • Approach
SA1Site Identification, Freestanding
SA2Building Identification, Freestanding
SA3Building Identification, Amenity Freestanding
SA4Vehicular Directional, Freestanding
SA5Parking Lot Identification
SA6Parking Space Identification
Section 5 • Enter
SE1 & SE2Embassy Identification, Seal and Legend
SE3Embassy Identification, Medium
SE4Embassy Identification, Small
SE5Building Identification, CAC
SE6Building Identification, Amenity
SE7Building Identification, Residential
SE8Pedestrian Directional, Freestanding
SE9Room Identification
SE10Door Identification, Overhead
SE11Vinyl Lettering
SE12Dedication Plaque
SE13LEED Sign
SE14Flag Pole
Section 6 • Find
SF1Directional, Freestanding
SF2Directional, Wall-mounted
SF3Directional, Ceiling-mounted
SF4Directional, Flag-mounted
Section 7 • Identify
SD1Room Identification, Large
SD2Room Identification, Medium
SD3Room Identification, Small
SD4Room Identification, Changeable
SD5Section Identification, Ceiling-mounted
SD6Workstation Directory
SD7Workstation Identification
SD8Restroom Identification
SD9Amenity, Flag-mounted
SD10Consular Window Identification, Overhead
SD11Consular Window Identification, Flag-mounted
SD12Residential Room Identification, Unit
SD13Residential Room Identification, Large
SD14Residential Room Identification, Medium
SD15Residential Room Identification, Small
Section 8 • Alert
SR1Alert, Extra-large
SR2Alert, Large
SR3Alert, Medium
SR4Alert, Small
SR5Alert, Vehicular
SR6Alert, Changeable Tabloid
SR7Alert, Changeable Letter
SR8Alert, Changeable Stanchion
SR9Bulletin Board
Section 9 • Inform
SN1Elevator, Emergency Egress Information
SN2Elevator Jamb, Floor Identification
SN3Elevator Jamb, EMS Identification
SN4Stair Identification, Occupancy Side
SN5Floor Identification, Stairwell Side
SN6Stair Identification, Stairwell Side

Blank Page

File details come from the government source that posted it. Updated .