This document is the OPSR 3 – OBO Project Requirements for FY26, specifically Section J.2.3 on Signage (OPR 12), issued October 1, 2025, by the U.S. Department of State's Overseas Buildings Operations division. The document establishes comprehensive graphic standards for embassy signage and wayfinding systems.
The standards define a standardized color palette with eight primary colors identified by designation codes (C1–C4, C10–C11, C20–C21) and three finish types (F1–F3), all with corresponding specifications in multiple color systems including Matthews Paint, Pantone PMS, 3M Scotchcal films, and 3M Scotchlite reflective films to ensure consistency across fabrication methods. Typography standards specify Calibre Regular and Medium typefaces (available from Klim Type Foundry) and Arial Regular, Italic, and Bold (from Monotype Type Foundry), with defined tracking parameters to optimize readability. The document provides a comprehensive symbols library including amenity icons, standard and emergency regulatory symbols, directional arrows, seal graphics, and extensive warning symbols covering hazards such as fire, electrical, chemical, and mechanical dangers. Two representative sign components are detailed: SF02 (Directional, Wall-mounted) designed for interior wayfinding with bilingual capabilities, and SR02 (Alert, Large) for emergency and regulatory information, both with dimensional specifications, material requirements, installation elevations, and graphic layout variations. A deviation process is established requiring architect or designer submissions to the Contracting Officer Representative for approval when standard colors or finishes conflict with specific architectural environments, with separate coordination permitted for exterior and interior conditions.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OPSR 3 – OBO PROJECT REQUIREMENTS | FY26
J.2.3
Signage
OPR 12
FY26
October 1, 2025
UNCLASSIFIED
UNCLASSIFIED
Extract
Graphic Standards
Description Page
Paint and Silkscreen Direct Print Adhesive Films
Color No.
Project Color Name Used Where Matthews Paint Match Pantone PMS
Opaque 3M™ Scotchcal™ ElectroCut™ Graphic Film Series 7725
Reflective 3M™ Scotchlite™ Reflective Graphic Film Series 680
C1 Accent Gray Accent border on pylons and signs
MP18249
Dark Pewter Metallic
Warm Gray 11 C
Petrolium Blue Metallic 247
N/A
C2 Secondary Gray Background seal, Direct print match for translations
MP18149
Dark Nickel Metallic
Warm Gray 9 C
Slate Metallic 201 N/A
C3 Regulatory Red Border and symbols on regulatory signs
MP10252
Campbells Soup Red
1805 C Geranium 63 Ruby Red 82
C4 Warning Yellow Border and symbols on warning signs
MP10211
Citrus Yellow
116 C Bright Yellow 15 Yellow 71
C10 Text Black Primary text color on all signs
MP40821
Draconia
Black 3 C Black 12 N/A
C11 Text Bronze Text color on bronze plaques
MP04418
Doric Brown
7533 C N/A N/A
C20 Background White
Background color on interior signs
MP32071
White Wonder
White White 10 White 10
C21 Background Silver
Background color on exterior pylon and plaque signs
MP18091
Silverstone Metallic
Warm Gray 2 C
Satin Aluminum 120 N/A
Finish Number
Project Color Name Used Where Finish
F1 Aluminum Embassy ID Light Horizontal Satin
F2 Bronze Dedication Plaques, Embassy ID Statuary Bronze
F3 Stainless Steel Dedication Plaques, Embassy ID Light Horizontal Satin
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
Paint systems indicated are for color match reference purposes only. Paint required for fabrication, including paint for backgrounds, lettering, screened copy, subsurface copy, etc., shall be compatible with the materials and to which it is applied. Finishes, materials, fabrication methods shall be appropriate for the environmental conditions in which the signage is installed.
All paint colors to have a satin non-glare finish in compliance with ABA 703.5.1 Finish and Contrast.
Color
EMBASSY OF THE
UNITED STATES
OF AMERICA
Embajada de Los Estados Unidos de América
Embajada de Los Estados Unidos de América
Sección de Asuntos Consulares
EMBASSY OF
THE UNITED STATES
OF AMERICA
CONSULAR AFFAIRS
SECTION
Amenity Translation Placement Here
Amenity Name Placement Here
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus
STAFF PARKING
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus lobortis euismod.
Workroom Sala de trabajo
506B RESTROOM
204A
IN CASE OF FIRE, ELEVATORS
ARE OUT OF SERVICE. USE EXIT STAIRS.
EN CASO DE INCENDIO, LOS ASCENSORES
ESTÁN FUERA DE SERVICIO.
USAR ESCALERAS DE SALIDA.
Workroom Sala de trabajo
506B RESTROOM
204A
IN CASE OF FIRE, ELEVATORS
ARE OUT OF SERVICE. USE EXIT STAIRS.
EN CASO DE INCENDIO, LOS ASCENSORES
ESTÁN FUERA DE SERVICIO.
USAR ESCALERAS DE SALIDA.
Embajada de Los Estados Unidos de América
Sección de Asuntos Consulares
EMBASSY OF
THE UNITED STATES
OF AMERICA
CONSULAR AFFAIRS
SECTION
Amenity Translation Placement Here
Amenity Name Placement Here
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus
STAFF PARKING
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Quisque id felis mattis, vestibulum arcu vitae, rutrum nisi. Vivamus nec ligula et risus lobortis euismod.
EMBASSY OF THE
UNITED STATES
OF AMERICA
Embajada de Los Estados Unidos de América
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
ARCHITECTURAL COLORS AND FINISHES
The colors and finishes indicated within these Standards have been selected to complement a wide range of architectural contexts. They are provided as the basis for all standard signage and are consistent from one post to another. Using the standard palette of colors assures that any supplier can fabricate these signs without any additional information, reducing the possibility for future coordination errors.
The color table, on the previous page, identifies each color or finish by a number. Each color is then defined in multiple color-systems to ensure consistency despite varying construction processes. Whether a fabricator utilizes silkscreen or direct print, the standards define an appropriate color system, allowing them to construct a consistent sign without ad hoc changes to the specifications.
Understanding that one solution may not be appropriate for all posts’ architectural finishes and materials, standard signage designs may need to be modified. Where conflicts occur and deviations are required to ensure signage adequately integrates into diverse environments, the COR (Contracting Officer
Representative) shall follow the Process for Deviations. Each variation to color or finish should be fully documented for each applicable color system for future implementations.
PROCESS FOR DEVIATIONS
1 The architect or designer proposes a change with a submission to the COR (Contracting Officer Representative).
A For the design phase, the COR will be the Project Manager
B For the construction phase, the COR will be the Project Director
2 COR reviews submission in conjunction with the design subject matter expert (architect, designer, landscape architect, engineer, etc.) and will either approve, comment, or reject requested deviation based on its impact.
3 Architect or designer resubmits and COR reviews as necessary to find a resolution.
INTERIOR SIGNAGEEXTERIOR SIGNAGE
STANDARDS
NEUTRAL PALETTE
SAMPLE
BRONZE-TONE
ARCHITECTURAL
DEVIATION
NOTE
The exterior and interior conditions should be considered independently and may require a separate coordination effort to align with their particular architectural finishes.
Color (continued)
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
Calibre Regular (Klim Type Foundry)
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
Calibre Medium (Klim Type Foundry)
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
NOTE
The Calibre typeface is available for purchase from the Klim Type Foundry:
https://klim.co.nz/retail-fonts/calibre/
The term "Tracking" used throughout the Standards refers to uniformly increasing or decreasing the horizontal spacing between a range of typographic characters to adjust the overall letterspacing. Tracking is utilized to improve the readability of type, especially of bold type weights or type set in all-caps.
TRACKING
Tracking: 0
TRACKING
Tracking: +50
TR ACKING
Tracking: +100
Typography
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
Arial Regular (Monotype Type Foundry)
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
Arial Italic (Monotype Type Foundry)
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890
Arial Bold (Monotype Type Foundry)
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
NOTE
The Arial typeface is available for purchase from the Monotype Type Foundry:
http://www.fontshop.com/fonts/family/arial/
Typography (continued)
Amenity
Standard Regulatory
Emergency Regulatory
Directional Seal Wail SoundHigh-Low Tone Fire Bell AlarmRapid Intermittent
Alarm Hi-Low AlarmStutter Alarm Soft Gong Alarm
No Cell PhonesNo Smoking No CamerasNo Wearables No LaptopsNo Audio Devices Egress Star Star Of LifeNo Food
Women’s RestroomUnisex Restroom AccessibleMen’s Restroom CashierStairs Parking
Black Seal Without Text
Arrow Up Arrow RightArrow DownArrow Left Cropped Seal
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
NOTE
Refer to the U.S. Department of State Brand System website for seal artwork. Do not scan or utilize the image in the OPSR.
https://brand.america.gov/d/DaSsgMXWCWUP/ our-brand#/visual-elements/the-seal
Symbols
UNCLASSIFIED
UNCLASSIFIED
https://brand.america.gov/d/DaSsgMXWCWUP/our-brand#/visual-elements/the-seal https://brand.america.gov/d/DaSsgMXWCWUP/our-brand#/visual-elements/the-seal
Cut / Sever Rotating Blade / Saw
UV LightFire, Flammable Cut / Sever / Shear Sharp Blade
Fall OxidizerCut / Sever Rotating Blade / Screw
Low Object: Head Hazard
Cut / Puncture Sharp Blade / Point
Lift Hazard Heavy Object
Pinch Rollers Skin Puncture Pressurized Air /
Water Jet
Automatic Start-upBurn Hazard Hot Surface
Pinch / Entanglement / Crush Gears
Tip Over Hazard Corrosive
General Danger Non-Ionizing Radiation Radio
Frequency Energy
Trip Pinch / Entanglement Gear / Chain Drive
Crush / Impact Hazard Foot
Laser LED Radiation Slip Crush / Impact Moving Parts Can
Crush & Cut
Explosion Arc Flash
Forklift
Pinch / Entanglement Roller Belt Drive /
Shear Point
Voltage, Body Shock, Electrocution Electric
Shock or Burn
Voltage Hazard, Electrocution Electric
Shock or Burn
Inhalation Hazard Hazardous Liquid
Voltage, Hazard Shock, Electrocution Electric
Shock or Burn
Voltage Hazard Shock in the Box
Voltage Hazard Electric Meter Shock
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
Symbols
Warning Symbols (1 of 3)
Do Not Remove PlugDo Not Turn Off (Button)
Do Not Switch Do Not Enter, Confined Space
No DiggingNo Welding No Digging Underground
Electrical Cable
Do Not Drink WaterNo Food of Drink No Dumping (Drain) Overhead Power Lines
Do Not Enter No Entry
Do Not Enter No Access for Unauthorized Persons
Eye Wash Wash HandsSafety Shower First Aid Station Fire ExtinguisherFirst Aid Kit Fire Ax Fire Hydrant Fire Plug
Fire Hose
Do Not Smoke No Smoking
Fire DoorFire Alarm Fire Exit (Right)Fire Exit (Left) Use Stairs In Case of Fire
Confined Space Watch For Oncoming Traffic
Needle Disposal Deposit Syringes Here
No Open Flames
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
Symbols
Warning Symbols (2 of 3)
Flammable Materials Gas
Flammable Materials Oxygen
Non-Flammable Materials
Gas
Flammable Liquid Flammable Liquid Fuel Oil
Oxidizer Harmful, Stow Away from Foodstuffs
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 2 • Graphic Standards SEPTEMBER 2024 VERSION 2.2
Symbols
Warning Symbols (3 of 3)
SF02
Sign Type Description Page
Mail Room Sala de Correo
Travel Section Sección de Viajes
Cafetería Cafeteria
Health Unit Unidad de Salud
Community Liaison O�ice Oficina de Enlace de la Comunidad
C - Side View Scale: 1 1/2"=1'-0" (1:8)
A - Front View Scale: 1 1/2"=1'-0" (1:8)
B - Plan View Scale: 1 1/2"=1'-0" (1:8)
D
D - Side View Detail Scale: 6"=1'-0" (1:2)
1'-
5/ 8"
(6 m m)
2'- 7 1
/4
(7 m m)
1'-3 3/4" (400 mm)
1'-5 1/4" (438 mm)
3/16" (5 mm)
1/4" (7 mm)
1/2" (13 mm)
3/4" (19 mm)
2" O
C T
YP
(5 1 m m)
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 6 • Find SEPTEMBER 2024 VERSION 2.2
SF02
Directional, Wall-mounted Component 1 of 3
DESCRIPTION
1 1/4" (7 mm) thick painted aluminum Border Panel with frisket painted Cropped Seal Symbol Border Panel Color: C1 Cropped Seal Symbol Color: C2
2 1/2" (13 mm) thick painted aluminum Face Panel with direct printed Directional Symbols, Text (English), Text (Translation), and Horizontal Rule;
mounted to Border Panel Face panel Color: C20 Directional Symbols Color: C10 Text (English) Color: C10 Text (Translation) Color: C2 Horizontal Rule Color: C10
3 3/16" (5 mm) thick painted Standoff Collar Standoff Collar Color: C20
| 4 | Wall |
| 5 | Fully concealed mechanical fastener |
NOTES
• Final material, finish, size, fabrication, mounting method, and placement to be approved by
OBO.
UNCLASSIFIED
UNCLASSIFIED
RideauPT Text Box or C99
Mail Room Sala de Correo
Travel Section Sección de Viajes
A - Graphic Layout, Example 1 Scale: 1 1/2"=1'-0" (1:8)
Community Liaison O�ice Oficina de Enlace de la Comunidad
Cafetería Cafeteria
Health Unit Unidad de Salud
B - Graphic Layout, Example 2 Scale: 1 1/2"=1'-0" (1:8)
LEVEL 3
Mail Room Sala de Correo
Travel Section Sección de Viajes
Community Liaison O�ice Oficina de Enlace de la Comunidad
Cafetería Cafeteria
Health Unit Unidad de Salud
Information System Central Sistema de Información Central
Other Message Here Otro mensaje aqui
Other Message Here Otro mensaje aqui
1 9/16" (39 mm)
1 1/16" (26 mm)
1 1/2" (38 mm)
1 1/16" MIN
(27 mm)
1'-3 3/4" (399 mm)
1'-2 1/8" (359 mm)
1'- 4 1
/4
(4 m m)
7 5 /8
(1 m
m) 2 1
/8
(5 4 m
m) 1 1
/2
(3 8 m m)
5/ 8"
(1 6 m m)
5/ 8"
(1 6 m
m) 5/
(9 m
m) 1"
(2 5 m
m) 1"
(2 5 m m)
1/
(2 m m)
1" (2
5 m m)
1 9/16" (39 mm)
1 1/16" (26 mm)
1 1/16" MIN
(27 mm)
1'-3 3/4" (399 mm)
1'-2 1/8" (359 mm)
1'- 4 1
/4
(4 m m)
2 1 /8
(5
4 m m)7/
8" (2
2 m m)
1 5 /1
6" (3
4 m m)
5/ 8"
(1 6 m
m) 5/
(7 m m)
1" (2
5 m m)
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 6 • Find SEPTEMBER 2024 VERSION 2.2
SF02
Directional, Wall-mounted Component 2 of 3
DESCRIPTION
| 1 | Cropped Seal Symbol: Symbols (page 22) |
| 2 | Directional Symbols: Symbols (page 22) |
| 3 | Typeface: Calibre Regular, Tracking: 0 |
| 4 | Horizontal Rule |
| 5 | Typeface: Calibre Medium, Tracking: 0 |
NOTES
• Directional Symbols and Text shown for graphic layout; OBO to approve final content.
• Include translation only if sign is located in front of the hard line and accessible by the general public.
A - Installation Elevation Scale: 1/2"=1'-0" (1:24)
Mail Room Sala de Correo
Travel Section Sección de Viajes
Cafetería Cafeteria
Health Unit Unidad de Salud
Community Liaison O�ice Oficina de Enlace de la Comunidad
4'- 0"
(1 cm
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 6 • Find SEPTEMBER 2024 VERSION 2.2
SF02
Directional, Wall-mounted Component 3 of 3
NOTES
• Sign to be installed level and plumb. Contractor to coordinate with architect/OBO to ensure installation will accommodate setting and wall conditions.
SR 02
Sign Type Description Page
A - Front View Scale: 3"=1'-0" (1:4)
C - Side View Scale: 3"=1'-0" (1:4)
B - Plan View Scale: 3"=1'-0" (1:4)
D
English messages that have a large character count should be placed here above the translation below.
Los mensajes en inglés que tienen un gran número de caracteres deben colocarse aquí arriba de la traducción a continuación.
D - Side View Detail Full Scale (1:1)
9" (229 mm)
1'- 3 3
/4
(4 m m)
1" O
C T
YP
(2 5 m m)
1/8" (3 mm)
1/8" (3 mm)
1/4" (6 mm)
3/8" (10 mm)
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2
SR02
Alert, Large Component 1 of 5
DESCRIPTION
1 1/8" (3 mm) thick painted acrylic Border Panel Border Panel Color: C3 or C4
2 1/4" (6 mm) thick painted acrylic Face Panel;
mounted to Border Panel Face Panel Color: C20
3 Direct printed Text (English) Text (English) Color: C10
4 Direct printed Text (Translation) Text (Translation) Color: C2
5 1/8" (3 mm) thick painted Standoff Collar Standoff Collar Color: C20
| 6 | Wall |
| 7 | Fully concealed mechanical fastener |
NOTES
• Final material, finish, size, fabrication, mounting method, and placement to be approved by
OBO.
Regulatory
SR.1
Warning
SR.2
Explanatory
SR.3
Duis mollis, est non nisi erat porttitor odio sem nec elit.
Duis mollis, est non nisi erat porttitor odio sem nec elit.
Duis mollis, est non nisi erat porttitor odio sem nec elit.
Duis mollis, est non nisi erat porttitor odio sem nec elit.
Duis mollis, est non nisi erat porttitor odio sem nec elit.
Duis mollis, est non nisi erat porttitor odio sem nec elit.
For more about sign classifications, refer to Sign Selection & Placement Guide Alert (page 13)
Fire:
Fire Bell Alarm
• Obey All Verbal Instructions Via P.A. System
• Secure Classified And Controlled Material
• Close All Windows And Doors
• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator
• Assemble In Rear Garden Area Or As Instructed
Bomb: Stutter Alarm (Rapid Intermittent)
• Obey All Verbal Instructions Via P.A. System
• Check WorzUnusual Items
• If Noted, Report Immediately To Post One
• Secure Classified And Controlled Material
• Open All Doors And Windows
• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator
• Proceed To Upper Garden Area Or As Instructed
Imminent Terrorist Attack:
Hi-lo Alarm (Alternating)
• Possible Attack In Front Of Embassy
• Do Not Secure Classified Material
• Remover Yourself From The Danger Area
(Front Windows, Front Facade Of The Building)
• Move To Back Rear Of The Building Towards Garden Area
• Await Further Verbal Instructions Over P.A. System
All Clear: Soft Gong Alarm
• Resume Normal Operations
Emergency Alarm Signals
All Electronics Prohibited Beyond This Point
Toda Las Electrónicas Prohibida Después de Este Punto
No Cell Phones No Celulares
No Recording Devices Sin Dispositivo de Grabación
No Wearables No Usablez
No Audio Devices No Dispositivos de Audio
No Laptops No Computadoras Portátiles
B - Example 2, SR2.1 Scale: 1 1/2"=1'-0" (1:8)
Emergency Alarm Tones
HIGH-LOW TONE: Police (Duck and Cover)
• Run Away From All Windows
• Duck Under Furniture
• Await Further Instructions
WAIL SOUND: Ambulance (Evacuate)
• Secure All Classified
• Close All Windows and Doors
• Do Not Lock Doors
• Evacuate Building Using the Nearest Emergency Exit
• Assemble in Designated Area for Further Instructions
RAPID INTERMITTENT HORN: Stutter (Safe Areas)
• Move To The Safe Areas
• Await Further Instructions
C - Example 3, SR2.1 Scale: 1 1/2"=1'-0" (1:8)
D - Example 4, SR2.1 Scale: 1 1/2"=1'-0" (1:8)
If you have a pacemaker or other internal medical device, please tell the security o�icer.
Si tiene un marcapasos u otro dispositivo médico interno, por favor, dígale al oficial de seguridad.
A - Example 1, SR2.1 Scale: 1 1/2"=1'-0" (1:8)
E - Example 5, SR2.2 Scale: 1 1/2"=1'-0" (1:8)
Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.
Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado negativo.
F - Example 5, SR2.3 Scale: 1 1/2"=1'-0" (1:8)
Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.
Etiam porta sem malesuada.
Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado negativo Etiam porta sem.
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2
SR02
Alert, Large Component 2 of 5
NOTES
• Signs may contain regulatory or warning information. For more about sign classifications, refer to Sign Selection & Placement Guide Alert (page 13).
English messages that have a large character count should be placed here above the translation below.
Los mensajes en inglés que tienen un gran número de caracteres deben colocarse aquí arriba de la traducción a continuación.
A - Graphic Layout 1 Scale: 6"=1'-0" (1:2)
3/4" (19 mm)
9/16" (14 mm)
9/16" MIN.
(14 mm)
3/ 4"
(1 9 m
m) 1"
(2 5 m
m) 1/
2" (1
3 m m)
5/
(8 m m)
/1
6" (2
1 m m)
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2
SR02
Alert, Large Component 3 of 5
DESCRIPTION
1 Typeface: Calibre Regular, Tracking: 0
NOTES
• Text shown for graphic layout; OBO to approve final content.
• Include translation only if sign is located in front of the hard line and accessible by the general public.
A - Graphic Layout Scale: 6"=1'-0" (1:2)
Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.
Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado
B - Graphic Layout 2 Scale: 6"=1'-0" (1:2)
5" (128 mm)
3/4" (19 mm)
9/16" (14 mm)
9/16" MIN.
(14 mm)
3/ 4"
(1 9 m
m) 1/
2" (1
3 m m)
5/
(8 m m)
/1
6" (2
1 m m)
3/ 4"
(1 9 m
m) 1 7
/8
(4 8 m
m) 9/
(1 4 m m)
/1 6"
(2 1 m
m) 1 15/16" (48 mm)
3/8" (9 mm)
ALIGN TO ARCHITECTURAL
ELEMENTS OR LIGHTING
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2
SR02
Alert, Large Component 4 of 5
DESCRIPTION
1 Regulatory or Warning Symbols:Symbols (page 22)
2 Typeface: Calibre Regular, Tracking: 0
NOTES
• Text shown for graphic layout; OBO to approve final content.
• Include translation only if sign is located in front of the hard line and accessible by the general public.
Fire:
Fire Bell Alarm
• Obey All Verbal Instructions Via P.A. System
• Secure Classified And Controlled Material
• Close All Windows And Doors
• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator
• Assemble In Rear Garden Area Or As Instructed
Bomb: Stutter Alarm (Rapid Intermittent)
• Obey All Verbal Instructions Via P.A. System
• Check WorzUnusual Items
• If Noted, Report Immediately To Post One
• Secure Classified And Controlled Material
• Open All Doors And Windows
• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator
• Proceed To Upper Garden Area Or As Instructed
Imminent Terrorist Attack:
Hi-lo Alarm (Alternating)
• Possible Attack In Front Of Embassy
• Do Not Secure Classified Material
• Remover Yourself From The Danger Area
(Front Windows, Front Facade Of The Building)
• Move To Back Rear Of The Building Towards Garden Area
• Await Further Verbal Instructions Over P.A. System
All Clear: Soft Gong Alarm
• Resume Normal Operations
Emergency Alarm Signals
Fire:
Fire Bell Alarm
• Obey All Verbal Instructions Via P.A. System
• Secure Classified And Controlled Material
• Close All Windows And Doors
• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator
• Assemble In Rear Garden Area Or As Instructed
Bomb: Stutter Alarm (Rapid Intermittent)
• Obey All Verbal Instructions Via P.A. System
• Check WorzUnusual Items
• If Noted, Report Immediately To Post One
• Secure Classified And Controlled Material
• Open All Doors And Windows
• Walk Immediately To Nearest Stairway Exit, Do Not Use Elevator
• Proceed To Upper Garden Area Or As Instructed
Imminent Terrorist Attack:
Hi-lo Alarm (Alternating)
• Possible Attack In Front Of Embassy
• Do Not Secure Classified Material
• Remover Yourself From The Danger Area
(Front Windows, Front Facade Of The Building)
• Move To Back Rear Of The Building Towards Garden Area
• Await Further Verbal Instructions Over P.A. System
All Clear: Soft Gong Alarm
• Resume Normal Operations
Emergency Alarm Signals
Workroom Sala de Trabajo
506B
All Electronics Prohibited Beyond This Point
Toda Las Electrónicas Prohibida Después de Este Punto
No Cell Phones No Celulares
No Recording Devices Sin Dispositivo de Grabación
No Wearables No Usablez
No Audio Devices No Dispositivos de Audio
No Laptops No Computadoras Portátiles
All Electronics Prohibited Beyond This Point
Toda Las Electrónicas Prohibida Después de Este Punto
No Cell Phones No Celulares
No Recording Devices Sin Dispositivo de Grabación
No Wearables No Usablez
No Audio Devices No Dispositivos de Audio
No Laptops No Computadoras Portátiles
A - Installation Elevation Scale: 3/8"=1'-0" (1:32)
B - Installation Elevation Scale: 3/8"=1'-0" (1:32)
C - Installation Elevation Scale: 3/8"=1'-0" (1:32)
D - Installation Elevation Scale: 3/8"=1'-0" (1:32)
If you have a pacemaker or other internal medical device, please tell the security o�icer.
Si tiene un marcapasos u otro dispositivo médico interno, por favor, dígale al oficial de seguridad.
Message here to contain a statement that indicates a possible danger, impending danger, or negative outcome.
Mensaje aquí para contener una declaración que indique un posible peligro, peligro inminente o resultado
4'- 6"
(1 ,37
2 m m)
5" (128 mm)
4'- 6"
(1 ,37
2 m m)
5" (128 mm)
4'- 6"
(1 ,37
2 m m)
4'- 6"
(1 ,37
2 m m)
3/4" (19 mm)
5" (128 mm)
5" (128 mm)
ALIGN
ALIGN TO ARCHITECTURAL
ELEMENTS OR LIGHTING
OPSR SIGNAGE & WAYFINDING STANDARDS / Section 8 • Alert SEPTEMBER 2024 VERSION 2.2
SR02
Alert, Large Component 5 of 5
NOTES
• Sign to be installed level and plumb. Contractor to coordinate with architect/OBO to ensure installation will accommodate setting and wall conditions.
| OPR 12 SIGNAGE |
| Table of Contents |
| Introduction |
| 1 Overview |
| 2 Signage & Wayfinding Design Standards |
| 3 Enclosure OBO Project Standard Requirements Signage & Wayfinding Design Standards |
| Table of Contents |
| Introduction |
| Section 1 • Signage Guidelines |
| Sign Selection & Placement Guide |
| Room Numbering Strategies |
| Code Reference |
| Section 2 • Graphic Standards |
| Color |
| Typography |
| Symbols |
| Section 3 • Sign Type Overview |
| Sign Type Overview |
| Section 4 • Approach | |
| SA1 | Site Identification, Freestanding |
| SA2 | Building Identification, Freestanding |
| SA3 | Building Identification, Amenity Freestanding |
| SA4 | Vehicular Directional, Freestanding |
| SA5 | Parking Lot Identification |
| SA6 | Parking Space Identification |
| Section 5 • Enter | |
| SE1 & SE2 | Embassy Identification, Seal and Legend |
| SE3 | Embassy Identification, Medium |
| SE4 | Embassy Identification, Small |
| SE5 | Building Identification, CAC |
| SE6 | Building Identification, Amenity |
| SE7 | Building Identification, Residential |
| SE8 | Pedestrian Directional, Freestanding |
| SE9 | Room Identification |
| SE10 | Door Identification, Overhead |
| SE11 | Vinyl Lettering |
| SE12 | Dedication Plaque |
| SE13 | LEED Sign |
| SE14 | Flag Pole |
| Section 6 • Find | |
| SF1 | Directional, Freestanding |
| SF2 | Directional, Wall-mounted |
| SF3 | Directional, Ceiling-mounted |
| SF4 | Directional, Flag-mounted |
| Section 7 • Identify | |
| SD1 | Room Identification, Large |
| SD2 | Room Identification, Medium |
| SD3 | Room Identification, Small |
| SD4 | Room Identification, Changeable |
| SD5 | Section Identification, Ceiling-mounted |
| SD6 | Workstation Directory |
| SD7 | Workstation Identification |
| SD8 | Restroom Identification |
| SD9 | Amenity, Flag-mounted |
| SD10 | Consular Window Identification, Overhead |
| SD11 | Consular Window Identification, Flag-mounted |
| SD12 | Residential Room Identification, Unit |
| SD13 | Residential Room Identification, Large |
| SD14 | Residential Room Identification, Medium |
| SD15 | Residential Room Identification, Small |
| Section 8 • Alert | |
| SR1 | Alert, Extra-large |
| SR2 | Alert, Large |
| SR3 | Alert, Medium |
| SR4 | Alert, Small |
| SR5 | Alert, Vehicular |
| SR6 | Alert, Changeable Tabloid |
| SR7 | Alert, Changeable Letter |
| SR8 | Alert, Changeable Stanchion |
| SR9 | Bulletin Board |
| Section 9 • Inform | |
| SN1 | Elevator, Emergency Egress Information |
| SN2 | Elevator Jamb, Floor Identification |
| SN3 | Elevator Jamb, EMS Identification |
| SN4 | Stair Identification, Occupancy Side |
| SN5 | Floor Identification, Stairwell Side |
| SN6 | Stair Identification, Stairwell Side |
Blank Page
File details come from the government source that posted it. Updated .