This is a Geotechnical Exploration Report prepared by AREHNA Engineering, Inc. for AECOM and Hillsborough County, Florida, concerning subsurface conditions at the intersection of County Line Road and Grand Hampton Drive in Tampa. The project involves constructing four new traffic signal poles—two permanent mast arm structures (northwest and southeast quadrants) and two temporary timber strain poles (northeast and southwest quadrants)—as part of Intersection Improvements for East County Line Road at Grand Hampton Drive with an estimated project cost of $1,239,930.07. The geotechnical exploration included four Standard Penetration Test borings (B-01 through B-04) drilled to depths of 40 to 45 feet below existing ground surface, conducted between December 26-27, 2023, with the report finalized on April 26, 2024. Field exploration was supplemented by laboratory testing including natural moisture content, sieve analysis, and Atterberg Limits testing on selected soil samples.
The subsurface conditions encountered consist primarily of loose to medium dense sands with varying amounts of fines from ground surface to depths of approximately 27 to 45 feet, with limestone formations encountered at deeper elevations requiring special excavation equipment and procedures. Groundwater levels were detected at depths of 5.8 to 8 feet below ground surface in borings B-03 and B-04, with estimated seasonal high water tables at 6.5 feet below ground surface for pole locations north of County Line Road and 5.5 feet for locations south of the road. The recommended geotechnical design parameters for the permanent mast arm foundations indicate that special site-specific designs are required, as soil conditions do not meet standard FDOT criteria for pre-designed structures. Design recommendations include specific friction angles, unit weights, and SPT N-values provided in Appendix C tables, with particular attention to limestone excavation challenges and the need for temporary casing methods when foundations are located within three shaft diameters of existing pole structures. The report emphasizes that both permanent and temporary pole installations should follow FDOT Standard Specifications and include provisions for dealing with the difficult-to-excavate limestone layer encountered during boring operations.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPORT OF GEOTECHNICAL EXPLORATION
MISCELLANEOUS STRUCTURES
COUNTY LINE ROAD AT GRAND HAMPTON DRIVE
TRAFFIC SIGNALS
HILLSBOROUGH COUNTY, FLORIDA
CIP 69600319
AREHNA PROJECT NO. B-22-011.02
January 16, 2024 (Revised April 26, 2024)
Prepared For:
AECOM
7650 W. Courtney Campbell Causeway Tampa, FL 33607
Prepared By:
AREHNA Engineering, Inc.
5012 West Lemon Street Tampa, FL 33609
5012 West Lemon Street Tampa, Florida 33609 Ph 954.417.8412 │ www.arehna.com
January 16, 2024 (Revised April 26, 2024)
Mr. Andrew K. Lloyd, PE
AECOM
7650 W. Courtney Campbell Causeway Tampa, FL 33607
Email: Andrew.Lloyd@aecom.com
Subject: Report of Geotechnical Exploration – Miscellaneous Structures County Line Road at Grand Hampton Drive Traffic Signals County Line Rd. and Grand Hampton Dr Hillsborough County, Florida
CIP 69600319
AREHNA Project B-22-011.02
AREHNA Engineering, Inc. (AREHNA) is pleased to submit this report of our geotechnical exploration for the proposed project. Services were conducted in general accordance with a Continuing Services Agreement dated August 23, 2023 and AREHNA supplemental agreement dated November 28, 2023.
This report presents our understanding of the project, outlines our exploratory procedures, documents the field data obtained, and provides geotechnical recommendations pertaining to design and construction of the new traffic signal mast arm poles at the intersection of County Line Road and Grand Hampton Drive.
AREHNA appreciates the opportunity to have assisted AECOM on this project. Should you have any questions with regards to this report, or if we can be of any further assistance, please contact this office.
Best Regards, AREHNA ENGINEERING, INC.
FLORIDA BOARD OF PROFESSIONAL ENGINEERS CERTIFICATE OF AUTHORIZATION NO. 28410
This item has been digitally signed and sealed by:
Sean Seibert, EI Kirk M. Eastman, P.E.
Engineer Intern Senior Geotechnical Engineer Florida Registration 50733
On the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319 iii
TABLE OF CONTENTS
Page
1.0 PROJECT INFORMATION
1.1 Site Description and Project Characteristics
1.2 Scope of Work
2.0 FIELD EXPLORATION AND LABORATORY TESTING
2.1 Field Exploration
2.2 Laboratory Testing
3.0 SUBSURFACE CONDITIONS
3.1 USGS Topographic Data
3.2 USDA Natural Resources Conservation Service Data
3.3 Subsurface Conditions
3.4 Groundwater Conditions
3.5 Estimated Seasonal High Water Level
4.0 ENGINEERING EVALUATION AND RECOMMENDATIONS
4.1 Recommended Geotechnical Parameters: Mast Arms
4.2 Temporary Timber Strain Pole Installation Recommendations
4.3 Construction Considerations
4.3.1 Mast Arm Poles
4.3.2 Temoprary Timber Strain Poles
5.0 ENVIRONMENTAL CLASSIFICATION
6.0 BASIS FOR RECOMMENDATIONS
LIST OF APPENDICES
APPENDIX A
USGS & USGS Vicinity Maps – Sheet 1
Report of Core Borings – Sheets 2 and 3
APPENDIX B
Summary of USDA Soil Survey – Table 1
Summary of Laboratory Test Results – Table 2
APPENDIX C
Recommended Design Soil Parameters for Mast Arm Foundations
Recommended design soil parameters for Temporary Timber Strain Poles – Table 3
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
1 | P a g e
1.0 PROJECT INFORMATION
1.1 SITE DESCRIPTION AND PROJECT CHARACTERISTICS
The project is located at the intersection of County Line Road and Grand Hampton Drive in Hillsborough County, Florida. The project consists of constructing four (4) new traffic signal poles. One pole is proposed for each quadrant of the subject intersection. We understand two (2) traffic signal poles located on the northeast and southwest quadrant are planned to be temporary timber strain poles. The remaining two (2) traffic signal poles located on the northwest and southeast quadrants are planned to be permanent mast arm structures.
This report presents our recommendations for the proposed traffic signal pole construction including our understanding of the project, a review of existing subsurface information, an outline of our exploratory procedures, summary of field and laboratory data obtained as well as our recommendations for site preparation, design, and construction.
1.2 SCOPE OF WORK
The primary purpose of the field exploration program was to determine the subsurface conditions for use in generating geotechnical design parameters for the planned traffic signal structures. In this regard, engineering assessments for the following items were formulated:
General location and description of potentially deleterious materials encountered in the boring which may have an impact on the proposed project.
Identification of the existing groundwater levels and estimated normal seasonal high groundwater fluctuations.
Provide recommended design soil parameters and geotechnical recommendations for drilled shaft foundation design for mast arm structures.
Provide recommended design soil parameters and geotechnical recommendations for temporary timber strain poles.
The following services were performed to achieve the above-outlined objective:
Requested utility location services from Sunshine 811.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
2 | P a g e
Performed four (4) Standard Penetration Test (SPT) boring near the proposed traffic signal pole locations to depths of 40 to 45 feet below the existing ground surface.
Visually classified and stratified soil samples in the laboratory using the Unified Soil
Classification System (USCS) and conducted a laboratory testing program including natural moisture content (ASTM D-2974), single sieve percent finer than #200 sieve gradation (ASTM D-1140), and Atterberg Limits (ASTM D-4318 & ASTM D-3282) on selected soil samples.
This report presents the results of the field exploration and engineering analysis signed and sealed by a professional engineer specializing in geotechnical engineering.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
3 | P a g e
2.0 FIELD EXPLORATION AND LABORATORY TESTING
2.1 FIELD EXPLORATION
The SPT borings (B-01 through B-04) were performed to depths of 40 to 45 feet below the existing ground surface (bgs). The boring locations were established in the field using Global Positioning System (GPS) equipment with an accuracy of ±10 feet based on the proposed pole location provided by AECOM. The borings on the north side of County Line Road (B-01 & B-02) were offset approximately 16 feet south of the proposed pole locations because of limited drill rig access due to the wooded area and a high-priority gas line running parallel to the tree line. Borings B-03 and B-04, on the southeast and southwest corners of the intersection, were offset approximately 5 feet east, and 2 feet south, respectively, from the proposed pole locations due to underground utility conflicts. The approximate boring location and approximate boring coordinates are provided on the Report of Core Borings Sheets in Appendix A. The soil profiles are on
Report of Core Borings Sheets are plotted to elevation based on topography data provided by AECOM.
The SPT borings were performed with the use of a Truck Mounted Drill Rig equipped with an automatic hammer using Bentonite “Mud” drilling procedures. Samples were collected and Standard Penetration Test resistances were measured continuously for the upper 10 feet and at approximate intervals of 5 feet, thereafter. The upper four feet were manually hand augered to avoid any potential conflict with unmarked underground utilities. The soil sampling was performed in general accordance with ASTM Test Designation
D-1586, entitled “Penetration Test and Split-Barrel Sampling of Soils.” Upon completion of drilling, the boreholes were backfilled with cement grout.
Representative samples from the borings were sealed in glass jars, labeled and transferred to AREHNA’S
Tampa office for appropriate classification by a geotechnical professional. Please note, samples will be retained for 90 days and then disposed of, unless other arrangements have been made.
2.2 LABORATORY TESTING
The soil samples were transported to AREHNA’s soils laboratory and were classified by a Geotechnical
Professional using the Unified Soil Classification System (USCS) in general accordance with the ASTM Test
Designation D-2488. Our laboratory testing program included natural moisture content tests (ASTM D-2974), single sieve percent finer than #200 sieve (ASTM D-1140), and Atterberg Limits (ASTM D-4318 & ASTM D-
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
4 | P a g e
3282). The laboratory test results are summarized on Table 2 in Appendix B and presented on the Report of
Core Borings sheets in Appendix A.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
5 | P a g e
3.0 SUBSURFACE CONDITIONS
3.1 USGS TOPOGRAPHIC DATA
The topographic survey map published by the United States Geological Survey was reviewed for ground surface features at the proposed project location (image on the right of Sheet 1 in Appendix A). Based on this review, the natural ground surface elevations at the project site are approximately between +45 to +50 feet
National Geodetic Vertical Datum of 1929 (NGVD 29). Topographic data provided by AECOM was reviewed and elevations were estimated at the boring locations between +50 to +51 feet North American Vertical
Datum of 1988 (NAVD 88). Elevations referenced in this report should be considered approximate; The boring locations were not survey at the time of this report.
3.2 USDA NATURAL RESOURCES CONSERVATION SERVICE DATA
The “Soil Survey of Hillsborough County, Florida,” (current online WebSoil Survey) published by the United
States Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) was reviewed for general near-surface soil information within the general project vicinity (see USDA Vicinity Map in
Appendix A). The information indicates that the soils at the project site consist of the following soil unit:
Table 3.2.1 Summary of USDA Soil Survey
Soil Unit
Number Soil Name
Depth Below Natural Grade to
High Water Table (feet)
29 Myakka fine sand, 0 to 2 percent slopes 0.5 – 1.5
The USDA Soil Survey map for the project site is presented on Sheet 1 in Appendix A (image to the left) and a detailed data table for this map unit is provided as Table 1 in Appendix B.
3.3 SUBSURFACE CONDITIONS
A pictorial representation of the subsurface conditions encountered in the borings is shown on the Boring
Profiles on the Report of Core Borings Sheets in Appendix A. The profiles and the following soil conditions highlight the general subsurface stratification. When reviewing the boring records and the subsurface soil profiles, it should be understood that soil conditions may vary between, and away from, boring locations.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
6 | P a g e
The SPT Borings (B-01 through B-04) generally encountered loose to medium dense sands with varying amounts of fines (SP, SP-SM, SM, SC) from the existing ground surface to depths of approximately 27 to 45 feet bgs. Beneath the sandy soils with varying fines, boring B-02 encountered hard limestone at a depth of 37 feet to the boring termination depth of 40 feet bgs. Beneath the sandy soils with varying fines, boring B-03 encountered very stiff silt (MH) from 32 to 37 feet bgs, followed by very stiff clay (CH) from 37 to 42 feet bgs.
Boring B-03 next encountered hard limestone to the boring termination depth of 45 feet bgs. Boring B-04 encountered firm stiff (MH) below the initial sandy soil strata from depths of 27 to 32 feet bgs, underlain by hard limestone to the boring termination depth of 45 feet bgs. We note that borings B-03 and B-04 encountered a 100% loss of circulation at depths of 36 and 35 feet bgs, respectively. Circulation was not regained before terminating the borings.
3.4 GROUNDWATER CONDITIONS
The groundwater level was encountered at approximate depths of 5.8 to 8 feet bgs in borings B-03 and B-04.
The groundwater level was not apparent in boring B-01. Drilling fluid was utilized in the SPT borings in order to advance the boreholes. The addition of fluid makes it difficult to obtain accurate groundwater measurements when the drilling fluid is introduced into the hole prior to encountering the groundwater table. As a result, GNA
(Groundwater Not Apparent) is shown adjacent to this soil profile. The groundwater level was also not apparent in boring B-02 due to clayey soils encountered within the top 10 feet of the boring. GNA is also shown adjacent to this soil profile.
Fluctuation in groundwater levels should be expected due to seasonal climatic changes, construction activity, rainfall variations, surface water runoff, and other site-specific factors. Since groundwater level variations are anticipated, design drawings and specifications should accommodate such possibilities and construction planning should be based on the assumption that variations will occur. The groundwater level is presented graphically adjacent to the soil profiles on Report of Core Borings Sheets in Appendix A.
3.5 ESTIMATED SEASONAL HIGH WATER LEVEL
The Seasonal High Water Table (SHWT) is the highest average depth of soil saturation during the wet season in a normal year (South West Florida Water Management District, SWFMD). Based on SWFWMD guidelines, the procedures for estimating SHWT elevations include an examination of county soil surveys and field verification by observation and identification of indicators within the soil profile. However, with the close
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
7 | P a g e proximity of the roadway and other improvements, the shallow soils are disturbed and no historical indicators of a SHWT were detected in the samples collected. The ground elevations at the borings were estimated from topographic data provided by AECOM. All borings, soil strata, and water tables in this report are referenced by depth below the existing ground surface.
Based on the USDA Soil Survey, field observations and our experience in the area, the estimated seasonal high water table should be expected at approximate depths of 6.5 feet bgs at the pole locations along the north of County Line Road and 5.5 feet bgs at the pole locations along the south side of County Line Road.
It should be noted that rainwater or surface runoff will tend to temporarily perch on top the shallow clayey soil near the existing ground surface at poles along the north side of County Line Road.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
8 | P a g e
4.0 ENGINEERING EVALUATION AND RECOMMENDATIONS
It is our understanding that drilled shaft foundations will be used for the proposed traffic signal mast arm poles. For the temporary strain poles, it is our understanding the foundations will consist of the embedded portion of the timber pole surrounded by compacted No. 57 Stone backfill. In our evaluation for the subject project, we have addressed the following geotechnical design and construction considerations:
Support of the proposed traffic signal mast arm drilled shaft foundations.
Recommendations for the installation of temporary timber strain poles.
4.1 RECOMMENDED GEOTECHNICAL PARAMETERS: MAST ARMS
We understand that the proposed mast arm poles will be designed by the Structural Engineer based on the
FDOT Standard Index 649-031 (Standard Mast Arm Assemblies). According to the FDOT Standard Plans Index
649-031, the mast arm poles are supported by drilled shaft foundations, which are pre-designed based upon the following soil criteria:
• Classification = Cohesionless (Fine Sand)
• Friction Angle = 30 degrees or greater
• Unit Weight = 50 pcf or greater (assumed submerged)
• N-blowcount ≥ 15
Based on the results of the mast arm traffic signal borings B-01 and B-03, the structure locations generally do not meet the established criteria and will require a special site-specific design.
Recommended soil parameters for the proposed mast arm foundations are provided in Appendix C. The parameters include average design values for soil type, soil unit weight, and angle of friction based on shaft tip depth beneath the surface. These parameters are based on our previous experience with projects utilizing similar structures in similar materials, as well as previous laboratory testing on similar materials and correlations with SPT N-values. In addition, the average SPT N-value of the boring (along the length of the shaft) should be used, and we recommend a design groundwater level at the ground surface (saturated condition).
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
9 | P a g e
4.2 TEMPORARY TIMBER STRAIN POLE INSTALLATION RECOMMENDATIONS
We understand that the proposed temporary timber strain poles will be designed by the Structural Engineer based on the FDOT Standard Specifications Section 102-9.12. As per the project plans, the temporary poles will include a guy wire/soil anchor system. The timber pole foundation will consist of the 12.5 feet embedded portion of the pole surrounded by compacted No. 57 Stone backfill.
Recommended soil parameters for the proposed pole foundations are presented on Table 3 in Appendix C.
The parameters include soil type, soil unit weight, and angle of friction. These parameters are based on our previous experience with projects utilizing similar structures in similar materials, as well as previous laboratory testing on similar materials and correlations with SPT N-values.
4.3 CONSTRUCTION CONSIDERATIONS
4.3.1 Mast Arm Poles
The drilled shafts for the mast arm pole structures should be installed in accordance with Florida
Department of Transportation (FDOT) Standard Specifications, Design Standards, and contract documents. We recommend the following plan note on adverse site conditions be included in the plans for the miscellaneous structure drilled shafts:
The limestone layer corresponds to a rock formation that typically offers high resistance to excavation. Special equipment and breaking tools may be required to excavate. This material is also difficult to dewater due to its porosity and permeability. Steps shall be taken to mitigate difficult drilled shaft installation and minimize the vibrations through the use of specialized equipment and/or procedures. This material was encountered in boring B-03 from an approximate depth of 42 feet to the boring termination depth of 45 feet below existing grades.
Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
10 | P a g e
If the shaft tip elevation is determined to be within one shaft diameter above very loose/soft soils
(N-value of less than 2) based on the design calculations only, the shaft should be extended below the very loose/soft soils into denser underlying material.
Nearby existing structures at the signal location consist of electric poles and strain poles. The existing pole foundations should be protected in accordance with Section 7-11.1 of the SSRBC. If the proposed foundation is located within three shaft diameters of the existing poles, use of temporary casing method is recommended in order to protect the existing pole foundations. In addition, the individual capacity of each foundation (existing pole foundation and new drilled shaft) may be reduced for center to center spacing less than 3 diameters.
4.3.2 Temoprary Timber Strain Poles
The temporary timber strain poles should be installed in accordance with FDOT Standard
Specifications, Design Standards, and contract documents. We recommend the following plan note on adverse site conditions be included in the plans for the temporary timber strain poles:
The limestone layer corresponds to a rock formation that typically offers high resistance to excavation. Special equipment and breaking tools may be required to excavate. This material is also difficult to dewater due to its porosity and permeability. Steps shall be taken to mitigate difficult timber pole installation and minimize the vibrations through the use of specialized equipment and/or procedures. This material was encountered in boring B-02 from an approximate depth of 37 feet to the boring termination depth of 40 feet below existing grades and in boring B-04 from an approximate depth of
32 feet to the boring termination depth of 45 feet, below existing grades.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
11 | P a g e
5.0 ENVIRONMENTAL CLASSIFICATION
Environmental corrosion parameter tests were not performed for the proposed structures. As per the FDOT
Soils & Foundation Handbook, the miscellaneous structures should be designed for the most aggressive conditions.
Report of Geotechnical Exploration April 26, 2024 County Line Rd at Grand Hampton Dr Signal Improvements AREHNA Project B-22-011.02 Hillsborough County, Florida CIP 69600319
12 | P a g e
6.0 BASIS FOR RECOMMENDATIONS
The evaluations and recommendations submitted in this report are based upon the data obtained from the soil borings performed at the locations indicated. Regardless of the thoroughness of a geotechnical exploration, there is always a possibility that conditions between borings will be different from those at specific boring locations and that conditions will not be as anticipated by the designers or contractors. In addition, the construction process itself may alter soil conditions. AREHNA is not responsible for the conclusions, opinions or recommendations made by others based on the data presented in this report.
The assessment of site environmental conditions or the presence of contaminants in the soil, rock, surface water or groundwater of the site was beyond the scope of this exploration. Any statements in this report regarding odors, staining of soils, or other unusual conditions observed are strictly for the information of
AECOM and Hillsborough County.
This report was prepared exclusively for AECOM and Hillsborough County by AREHNA. The quality of information, conclusions and estimates contained herein is consistent with the level of effort involved in
AREHNA’s services and based on: i) information available at the time of preparation, ii) data supplied by outside sources and iii) the assumptions, conditions and qualifications set forth in this report. This report is intended to be used by AECOM and Hillsborough County only. Any other use of, or reliance on, this report by any third party is at that party’s sole risk.
APPENDIX A
USDA & USGC Vicinity Maps – Sheet 1
Report of Core Borings – Sheets 2 and 3
USDA SOIL SURVEY MAP USGS TOPOGRAPHIC MAP
N
Feet
0 250
N
Feet
0 250
SECTION:
RANGE:
TOWNSHIP:
SECTION:
RANGE:
TOWNSHIP:
REFERENCE: USDA SOIL SURVEY OF HILLSBOROUGH COUNTY, FLORIDA
1/5/2024613767 D:\1-Arehna\Projects\2022\B-22-011.02 - County Line Rd and Grand Hampton\RDSSGEO.DGN4:47:06 PM
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
CIP NO. SHT. NO.
USDA & USGS VICINITY MAPS
PUBLIC WORKS DEPARTMENT
TECHNICAL SERVICES DIVISION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
TAMPA, FL 33609
5012 W. LEMON STREET
AREHNA ENGINEERING, INC.
P.E. LICENSE NUMBER 50733
KIRK M. EASTMAN, P.E.
69600319
COUNTY LINE RD AT GRAND HAMPTON DR
APPROXIMATE PROJECT LOCATION APPROXIMATE PROJECT LOCATION
REFERENCE: "LUTZ, FLORIDA" USGS QUADRANGLE MAP
19 E
27 S
19 E
27 S
SAND
SILTY SAND
SAFETY HAMMER
MEDIUM DENSE
AUTOMATIC HAMMER
GRANULAR MATERIALS-
SPT N-VALUE
GREATER THAN 24
LESS THAN 3
(BLOWS/FT.)
SPT N-VALUE
(BLOWS/FT.)
GREATER THAN 40
3 to 8
16 to 30
8 to 15
LESS THAN 1
3 to 6
1 to 3
LEGEND
6 to 12
24 to 40
8 to 24
12 to 24
CONSISTENCY
FIRM
SOFT
VERY STIFF
STIFF
SILTS AND CLAYS
VERY SOFT
4 to 8
2 to 4
RELATIVE DENSITY
LOOSE
DENSE
VERY DENSE
(BLOWS/FT.)
SPT N-VALUE
(BLOWS/FT.)
30 to 50
10 to 30
4 to 10
SPT N-VALUE
LESS THAN 2
VERY LOOSE
HARD GREATER THAN 30
LESS THAN 4
GREATER THAN 50
(UNLESS OTHERWISE NOTED).
SPT VALUE FOR 12 INCHES OF PENETRATION
NUMBERS TO THE LEFT OF BORINGS INDICATEN
HA HAND AUGER
SP
GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW
UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2488)
CLAYEY SAND
APPROXIMATE SPT BORING LOCATION
LIMESTONE
GNA
GROUNDWATER TABLE
GROUNDWATER TABLE NOT APPARENT
NUMBER OF BLOWS FOR 4 INCHES OF PENETRATION50/4
LOSS OF CIRCULATION OF DRILLING FLUID (%)100
NMC
-200
NATURAL MOISTURE CONTENT (%)
PLASTICITY INDEX (%)PI
LIQUID LIMIT (%)LL
FINES PASSING THE #200 STANDARD SIEVE (%)
CLAY
SILT
NOTE:
THE LIMESTONE LAYER CORRESPONDS TO A ROCK FORMATION THAT
TYPICALLY OFFERS HIGH RESISTANCE TO EXCAVATION. SPECIAL
EQUIPMENT AND BREAKING TOOLS MAY BE REQUIRED TO EXCAVATE.
THIS MATERIAL IS ALSO DIFFICULT TO DEWATER DUE TO ITS POROSITY
AND PERMEABILITY. STEPS SHALL BE TAKEN TO MITIGATE DIFFICULT
DRILLED SHAFT INSTALLATION AND MINIMIZE THE VIBRATIONS
THROUGH THE USE OF SPECIALIZED EQUIPMENT AND/OR PROCEDURES.
THIS MATERIAL WAS ENCOUNTERED IN BORING B-03 FROM AN
APPROXIMATE DEPTH OF 42 FEET TO THE BORING TERMINATION DEPTH
OF 45 FEET BELOW EXISTING GRADES.
BOR #
DATE
DRILLER
HAMMER AUTOMATIC
RIG
STA.
REF.
OFF.
ELEV.
N
M. SEIBERT
CME-45
E L E
V A
T I O
N
(F
E E
T
N A
V D
-5
E L E
V A
T I O
N
(F
E E
T
N A
V D
-5
HA
HA
ELEVATION 5 FT (NAVD 88)
BORING TERMINATED AT
12/26/2023
50 FT
¡ COUNTY LINE RD
B-01 BOR #
DATE
DRILLER
HAMMER AUTOMATIC
RIG
STA.
REF.
OFF.
ELEV.
N
M. SEIBERT
CME-45
HA
HA
12/27/2023
¡ COUNTY LINE RD
B-03
12+46
23 LT
13+12
51 RT
50.5 FT
GNA
ELEVATION 5.5 FT (NAVD 88)
BORING TERMINATED AT
LONGITUDE: W 82.3772596
LATITUDE: N 28.1704645
LONGITUDE: W 82.3770738
LATITUDE: N 28.1702476
9 7
50/5
BROWN SAND (SP)
BROWN CLAYEY SAND (SC)
GRAY TO BROWN CLAYEY SAND (SC)
BROWN SLIGHTLY SILTY SAND (SP-SM)
GRAY SAND (SP)
LIGHT BROWN SAND (SP)
GRAY TO LIGHT BROWN SILTY SAND (SM)
GRAY TO BROWN TO LIGHT GRAY SAND (SP)
BROWN SLIGHTLY SILTY SAND (SP-SM)
GRAY TO LIGHT BROWN SLIGHTLY SILTY SAND (SP-SM)
BROWN SAND WITH TRACE ROOT (SP)
GRAY SILTY SAND (SM)
BROWN SILT WITH FEW LIMESTONE FRAGMENTS (MH)
DARK BROWN TO DARK GRAY SLIGHTLY SILTY SAND
WITH FEW ORGANICS (SP-SM)
55 55
DARK BROWN SLIGHTLY SILTY SAND WITH
TRACE ORGANICS (SP-SM)
BROWN SILTY SAND (SM)-200=14
NMC=19
-200=31
NMC=33
-200=16
NMC=17
-200=73
NMC=64
BROWN SILTY SAND WITH LIMESTONE
FRAGMENTS (SM)
LIGHT BROWN LIMESTONE
BLUE CLAY WITH FEW LIMESTONE FRAGMENTS (CH)
N
Feet
0 10
B-01 B-02
B-03 B-04
COUNTY LINE RD
H A
M P
T O
D R
G
A N
D
T H
E
F
F I
C I
A L
C O
T
I
S
E E
T
E C
T R
O N
C
G I
T A
L
Y
G N
A L
U
D
L E
G
A
C
4/22/2024613767 D:\1-Arehna\Projects\2022\B-22-011.02 - County Line Rd and Grand Hampton\B1BORING01.DGN9:45:28 AM
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
REPORT OF CORE BORINGS 2
COUNTY LINE RD AT GRAND HAMPTON DR
69600319
PUBLIC WORKS DEPARTMENT
TECHNICAL SERVICES DIVISION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
MAST ARM POLES
TAMPA, FL 33609
5012 W. LEMON STREET
AREHNA ENGINEERING, INC.
P.E. LICENSE NUMBER 50733
KIRK M. EASTMAN, P.E.
SAND
SILTY SAND
SAFETY HAMMER
MEDIUM DENSE
AUTOMATIC HAMMER
GRANULAR MATERIALS-
SPT N-VALUE
GREATER THAN 24
LESS THAN 3
(BLOWS/FT.)
SPT N-VALUE
(BLOWS/FT.)
GREATER THAN 40
3 to 8
16 to 30
8 to 15
LESS THAN 1
3 to 6
1 to 3
LEGEND
6 to 12
24 to 40
8 to 24
12 to 24
CONSISTENCY
FIRM
SOFT
VERY STIFF
STIFF
SILTS AND CLAYS
VERY SOFT
4 to 8
2 to 4
RELATIVE DENSITY
LOOSE
DENSE
VERY DENSE
(BLOWS/FT.)
SPT N-VALUE
(BLOWS/FT.)
30 to 50
10 to 30
4 to 10
SPT N-VALUE
LESS THAN 2
VERY LOOSE
HARD GREATER THAN 30
LESS THAN 4
GREATER THAN 50
(UNLESS OTHERWISE NOTED).
SPT VALUE FOR 12 INCHES OF PENETRATION
NUMBERS TO THE LEFT OF BORINGS INDICATEN
HA HAND AUGER
SP
GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW
UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2488)
CLAYEY SAND
APPROXIMATE SPT BORING LOCATION
LIMESTONE
GNA
GROUNDWATER TABLE
GROUNDWATER TABLE NOT APPARENT
NUMBER OF BLOWS FOR 4 INCHES OF PENETRATION50/4
LOSS OF CIRCULATION OF DRILLING FLUID (%)100
NMC
-200
NATURAL MOISTURE CONTENT (%)
PLASTICITY INDEX (%)PI
LIQUID LIMIT (%)LL
FINES PASSING THE #200 STANDARD SIEVE (%)
CLAY
SILT
NOTE:
THE LIMESTONE LAYER CORRESPONDS TO A ROCK FORMATION THAT
TYPICALLY OFFERS HIGH RESISTANCE TO EXCAVATION. SPECIAL
EQUIPMENT AND BREAKING TOOLS MAY BE REQUIRED TO EXCAVATE.
THIS MATERIAL IS ALSO DIFFICULT TO DEWATER DUE TO ITS POROSITY
AND PERMEABILITY. STEPS SHALL BE TAKEN TO MITIGATE DIFFICULT
THROUGH THE USE OF SPECIALIZED EQUIPMENT AND/OR PROCEDURES.
THIS MATERIAL WAS ENCOUNTERED IN BORING B-02 FROM AN
APPROXIMATE DEPTH OF 37 FEET TO THE BORING TERMINATION OF 40
FEET BELOW EXISTING GRADES AND IN BORING B-04 FROM AN
APPROXIMATE DEPTH OF 32 FEET TO THE BORING TERMINATION DEPTH
OF 45 FEET BELOW EXISTING GRADES.
TIMBER POLE INSTALLATION AND MINIMIZE THE VIBRATIONS
BOR #
DATE
DRILLER
HAMMER AUTOMATIC
RIG
STA.
REF.
OFF.
ELEV.
N
M. SEIBERT
CME-45
HA
HA
12/26/2023
50 FT
¡ COUNTY LINE RD
B-02
E L E
V A
T I O
N
(F
E E
T
N A
V D
-5
E L E
V A
T I O
N
(F
E E
T
N A
V D
-5
BOR #
DATE
DRILLER
HAMMER AUTOMATIC
RIG
STA.
REF.
OFF.
ELEV.
N
M. SEIBERT
CME-45
HA
HA
12/27/2023
¡ COUNTY LINE RD
B-04
12+89
22 LT
50.5 FT
11+88
58 RT
GNA
ELEVATION 10 FT (NAVD 88)
BORING TERMINATED AT
ELEVATION 5.5 FT (NAVD 88)
BORING TERMINATED AT
LONGITUDE: W 82.3771267
LATITUDE: N 28.1704544
LONGITUDE: W 82.3774613
LATITUDE: N 28.1702546
50/4
50/4
50/3
BROWN SAND (SP)
GRAY TO BROWN CLAYEY SAND (SC)
GRAY CLAYEY SAND (SC)
GRAY TO BROWN CLAYEY SAND (SC)
DARK GRAY TO GRAY SLIGHTLY SILTY SAND (SP-SM)
BROWN CLAYEY SILTY SAND (SC-SM)
GRAY TO LIGHT BROWN SAND (SP)
BROWN CLAYEY SILTY SAND (SC-SM)
LIGHT BROWN LIMESTONE
GRAY SLIGHTLY SILTY SAND (SP-SM)
GRAY SAND WITH TRACE CLAY CHUNKS (SP)
GRAY TO BROWN TO LIGHT BROWN SAND (SP)
GRAY SILTY SAND (SM)
55 55
GRAY TO LIGHT BROWN SLIGHTLY SILTY SAND (SP-SM)
-200=21
NMC=15
-200=8
NMC=20
PI=22
LL=39
-200=38
NMC=16
-200=25
NMC=20
LIGHT BROWN LIMESTONE
LIGHT BROWN CLAYEY LIMESTONE
BROWN TO GRAY SILT WITH TRACE LIMESTONE FRAGMENTS (MH)
N
Feet
0 10
B-01 B-02
B-03 B-04
COUNTY LINE RD
H A
M P
T
G
A N
D
T
F I
C I
C O
E E
T
E C
T R
O N
C
G I
T A
L
Y
G N
A L
D
L E
G
A
C
4/22/2024613767 D:\1-Arehna\Projects\2022\B-22-011.02 - County Line Rd and Grand Hampton\B1BORING02.DGN9:45:35 AM
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
REPORT OF CORE BORINGS 3
COUNTY LINE RD AT GRAND HAMPTON DR
69600319
PUBLIC WORKS DEPARTMENT
TECHNICAL SERVICES DIVISION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
TEMPORARY TIMBER STRAIN POLES
TAMPA, FL 33609
5012 W. LEMON STREET
AREHNA ENGINEERING, INC.
P.E. LICENSE NUMBER 50733
KIRK M. EASTMAN, P.E.
APPENDIX B
Summary of USDA Soil Survey – Table 1
Summary of Laboratory Test Results – Table 2
Depth
(feet)
Duration
(months) Kind Steel Concrete
0 - 6 Fine sand A-2-4, A-3 SP-SM, SM
6 - 20 Sand, fine sand A-2-4, A-3 SP-SM, SM
20 -36 Fine sand, sand A-2-4, A-3 SP-SM, SM
36 - 80 Fine sand, sand A-2-4, A-3 SP-SM, SM
0.6 - 6
Myakka fine sand, 0 to 2 percent slopes
(29)
0.5 - 1.5 Jun - Nov Apparent High High
USDA Soil Type Depth
(inches)
Risk of Corrosion
AASHTO USCS
Permeability
(in/hr)
Seasonal High Groundwater
USDA Soil Description
TABLE 1
SUMMARY OF USDA SOIL SURVEY
COUNTY LINE ROAD AT GRAND HAMPTON DRIVE SIGNAL IMPROVEMENTS
AREHNA Project No.: B-22-011.02
HILLSBOROUGH COUNTY, FLORIDA
CIP 69600319
#200 Liquid
Limit
Plasticity
Index
B-01 8 - 10 SM 14 - - 19
B-01 38.5 - 40 SM 31 - - 33
B-02 6 - 8 SC-SM 21 - - 15
B-02 18.5 - 20 SP-SM 8 - - 20
B-03 13.5 - 15 SM 16 - - 17
B-03 33.5 - 35 MH 73 - - 64
B-04 8 - 10 SC 38 39 22 16
B-04 18.5 - 20 SM 25 - - 20
Natural
Moisture
Content
HILLSBOROUGH COUNTY, FLORIDA
TABLE 2
SUMMARY OF LABORATORY TEST RESULTS
COUNTY LINE ROAD AT GRAND HAMPTON DRIVE SIGNAL IMPROVEMENTS
AREHNA PROJECT NO. B-22-011.02
Boring No.
Sample
Depth
(feet)
AASHTO
Classification
Sieve Analysis Atterberg Limits
CIP 69600319
APPENDIX C
Recommended Design Soil Parameters for Temporary Timber Strain Poles – Table 3
APPENDIX C (Continued)
5012 W. Lemon Street
Tampa, FL 33609
Project Name: County Line Rd at Grand Hampton Dr Traffic Signals
Project Number: B-22-011.02
Boring No.: B-01
Boring GSE (ft, NAVD): 50
Prepared by/Date: SPS/1-2-2024
Checked by/Date: KE/1-10-2024
From To
Clayey Sand SC 0 2 5 6.2 25 105 42.6
Sand SP 2 4 5 6.2 30 105 42.6
Sand with silt SP-SM 4 6 22 27.3 35 115 52.6
Sand SP 6 8 19 23.6 34 115 52.6
Silty Sand SM 8 13 9 11.2 31 112 49.6
Sand with silt SP-SM 13 15 5 6.2 30 105 42.6
Clayey Sand SC 15 20 16 19.8 33 115 52.6
Sand SP 20 25 15 18.6 33 115 52.6
Sand SP 25 30 11 13.6 31 112 49.6
Silty Sand SM 30 35 3 3.7 29 102 39.6
Silty Sand SM 35 40 5 6.2 30 105 42.6
Silty Sand SM 40 45 9 11.2 31 112 49.6
Version 1.10 (Created By/ Date: ALA/09-18-15 & Checked By/Date: CJR/09-21-15)
Boring No.
Drilled Shaft
Length (ft)
Equivalent SPT N
(manual hammer), bpf
Equivalent
Average Internal
Friction Angle, f
(Degrees)
Equivalent
Total Soil
Unit Weight, g (pcf)
Equivalent
Effective
(Submerged)
Soil Unit
Weight, g' (pcf)
Comment
B-01 12 14 31 112.4 50 Special Design Required
14 13 31 112.4 50 Special Design Required
16 13 31 112.4 50 Special Design Required
18 14 31 112.4 50 Special Design Required
20 15 31 112.4 50 Use Index 649-030
25 15 31 112.4 50 Use Index 649-030
30 15 31 112.4 50 See Note 1
35 14 31 112.4 50 Special Design Required
40 13 31 112.4 50 Special Design Required
45 12 31 112.4 50 Special Design Required
Notes:
3. Assume unsupported length from 0 to 2 feet depth from ground surface due to organic soils. Shaft Length shown in the table below refers to supported shaft length.
Mast Arm Structures - Equivalent Soil Parameters Estimation (Cohesionless)
Note: Unless noted below, we recommend the design groundwater level at the ground surface. If existing grades need to be raised, assume the following soil parameters for the new sand fill: Internal Friction Angle of 30 degrees, Total Unit Weight of 105 pcf, and Effective (Submerged) Soil Unit Weight of 42.6 pcf, and SPT of 10 bpf.
See Report of Core Borings
2. Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.
1. The average soil strength properties meet or exceed the minimum required soil criteria shown on the FDOT Standard Plans Instructions for Index 649-030. However, the foundation embedment depths shown in Standard Plans Index 649-030 are different than the depth evaluated and a special design may be required.
Mast Arm Structures - Recommended Design Soil Parameters (Cohesionless)
Location
(Station & Offset/ Baseline)
Soil Description Modeled as
Depth
(ft.)
SPT N
(automatic hammer), bpf
SPT N
(manual hammer), bpf
Internal
Friction
Angle, f
(Degrees)
Total Soil Unit
Weight, g
(pcf)
Effective (Submerged) Soil
Unit Weight, g' (pcf)
5012 W. Lemon Street
Tampa, FL 33609
Project Name: County Line Rd at Grand Hampton Dr Traffic Signals
Project Number: B-22-011.02
Boring No.: B-03
Boring GSE (ft, NAVD): 50.5
Prepared by/Date: SPS/1-2-2024
Checked by/Date: KE/1-10-2024
From To
Sand with silt SP-SM 0 2 5 6.2 30 105 42.6
Sand SP 2 4 5 6.2 30 105 42.6
Sand SP 4 6 14 17.4 32 112 49.6
Sand with silt SP-SM 6 8 13 16.1 32 112 49.6
Sand SP 8 13 7 8.7 30 112 49.6
Silty Sand SM 13 15 13 16.1 32 112 49.6
Sand with silt SP-SM 15 20 16 19.8 33 115 52.6
Sand with silt SP-SM 20 25 14 17.4 32 112 49.6
Sand with silt SP-SM 25 30 11 13.6 31 112 49.6
Silt MH 30 35 21 26.0 35 115 52.6
Fat Clay CH 35 40 15 18.6 ----- 140 77.6
Limestone NA 40 45 100 124.0 38 130 67.6
Version 1.10 (Created By/ Date: ALA/09-18-15 & Checked By/Date: CJR/09-21-15)
Boring No.
Drilled Shaft
Length (ft)
Equivalent SPT N
(manual hammer), bpf
Equivalent
Average Internal
Friction Angle, f
(Degrees)
Equivalent
Total Soil
Unit Weight, g (pcf)
Equivalent
Effective
(Submerged)
Soil Unit
Weight, g' (pcf)
Comment
B-03 12 11 31 112.4 50 Special Design Required
14 11 31 112.4 50 Special Design Required
16 12 31 112.4 50 Special Design Required
18 13 31 112.4 50 Special Design Required
20 13 31 112.4 50 Special Design Required
25 14 32 112.4 50 Special Design Required
30 14 32 112.4 50 Special Design Required
35 16 32 112.4 50 See Note 1
40 16 28 112.4 50 Special Design Required
45 28 29 112.4 50 Special Design Required
Notes:
3. Assume unsupported length from 0 to 2 feet depth from ground surface due to organic soils. Shaft Length shown in the table below refers to supported shaft length.
Mast Arm Structures - Equivalent Soil Parameters Estimation (Cohesionless)
Note: Unless noted below, we recommend the design groundwater level at the ground surface. If existing grades need to be raised, assume the following soil parameters for the new sand fill: Internal Friction Angle of 30 degrees, Total Unit Weight of 105 pcf, and Effective (Submerged) Soil Unit Weight of 42.6 pcf, and SPT of 10 bpf.
See Report of Core Borings
2. Foundations should not be tipped/embedded within one shaft diameter above very loose/soft soils with automatic hammer N-values of less than 2 blows per foot (N < 2 bpf) to reduce the risk of excessive settlement of the shaft and the potential for instability of the shaft bottom during construction.
1. The average soil strength properties meet or exceed the minimum required soil criteria shown on the FDOT Standard Plans Instructions for Index 649-030. However, the foundation embedment depths shown in Standard Plans Index 649-030 are different than the depth evaluated and a special design may be required.
Mast Arm Structures - Recommended Design Soil Parameters (Cohesionless)
Location
(Station & Offset/ Baseline)
Soil Description Modeled as
Depth
(ft.)
SPT N
(automatic hammer), bpf
SPT N
(manual hammer), bpf
Internal
Friction
Angle, f
(Degrees)
Total Soil Unit
Weight, g
(pcf)
Effective (Submerged) Soil
Unit Weight, g' (pcf)
APPENDIX C (Continued)
Recommended Design Soil Parameters for Temporary Timber Strain Poles – Table 3 ɣ SAT ɣ SUB
0-12 14 SC, SP-SM, SP, SC-SM 105 42.6 - 31 0.323 3.099
12-27 20 SC, SP-SM, SP 110 47.6 - 32 0.307 3.255
27 - 37 9 SP, SC-SM 105 42.6 - 30 0.336 2.976
37-40 100 LIMESTONE 135 72.6 12,000 - 1.000 1.000
0 - 17 15 SP, SC, SP-SM 105 42.6 - 31 0.320 3.124
17 - 27 9 SM 105 42.6 - 30 0.336 2.976
27 - 32 7 MH 110 47.6 875 - 1.000 1.000
32 - 45 89 LIMESTONE 135 72.6 11,120 - 1.000 1.000
BORING
NUMBER
DEPTH
(FEET)
SPT "N"
AVERAGE
SOIL CLASSIFICATION
APPROXIMATE SOIL UNIT
WEIGHT (PCF)
COHESION
(PSF)
B-04
TABLE 3
RECOMMENDED DESIGN SOIL PARAMETERS FOR TEMPORARY TIMEBER STRAIN POLES
COUNTY LINE ROAD AT GRAND HAMPTON DRIVE SIGNAL IMPROVEMENTS
HILLSBOROUGH COUNTY, FLORIDA
CIP 69600319
AREHNA Project No.: B-22-011.02