18-416 Bid CombDWG 20210223_Part3.pdf

PDF 6 MB Posted

Attached to
Z2DZ--Upgrade Chiller Plant (VA-21-00024244)
Solicitation number
36C25921R0061
Issued by

About this file

This is a presolicitation notice for an upgrade chiller plant project at the Jack C. Montgomery VA Medical Center in Muskogee, Oklahoma. The project magnitude is estimated between $5-10 million and is set aside 100% for service-disabled veteran-owned small businesses. A request for quote will be posted on April 15, 2021. The NAICS code is 238220 and small business size standard is $39.5 million. The point of contact is Robyn Young who can be reached at 307-433-3728 or robyn.young2@va.gov. Apparent successful offerors must be verified and listed in the Vendor Information Pages database as a service-disabled veteran-owned small business to be considered for award. The contractor will provide construction services to complete the upgrade chiller plant project.

View the file

Other files

File Type Posted
36C25921R0061 0003.docx DOCX document
G-101.pdf PDF
Pre Bid RFIs - 18-416.pdf PDF
013526 Safety Reqs.pdf PDF
18-416 Bid CombSpecs 20210223-RFI.pdf PDF
36C25921R0061 0002.docx DOCX document
36C25921R0061 0001.docx DOCX document
S04 -Site Visit Meeting Doc.pdf PDF
IMG_0257.jpg JPG image
Site Visit Station Map.pdf PDF
18-416 Bid CombDWG 20210223_Part2.pdf PDF
36C25921R0061_1.docx DOCX document
S02 Past Performance Questionnaire.docx DOCX document
18-416 Bid CombDWG 20210223_Part1.pdf PDF
Site Visit Hatbox Parking.pdf PDF
18-416 Bid CombSpecs 20210223.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

52-CH-3

EX 52-CH-2

EX 52-CH-1

52-P-12

EX 52-P-2

EX 52-P-5

52-P-6

10"

CHS10"

CHR

12"

CHR

16" CHS

16" CHS

16" CHS

C H S

C H S

C H S

C H R

C H R

C H R

C H R

C H S

C H S

12" CHR

12" CHR

16" CHR

16" CHS

16" CHS

16" CHS

16" CHR

16" CHS16" CHR

16" CHS16" CHR

C H R

12" CHS

12" CHS

12" CHS 12" CHR

12"

CHS

52-P-4

52-P-1

C H R

C H R

C H R

C H S

C H S

52-CH-3

52-P-12

52-P-6

16" CHS

16" CHS

16" CHS

16" CHR

16" CHS

16" CHS

12" CHR

16" CHR

16" CHS

16" CHS

16" CHR

12" CHR

16" CHR

16" CHR

16" CHS

C H S

C H R

C H R

C H R

C H R

C H S

C H S

C H S

12" CHS

12" CHS

12" CHS

12" CHR

12"

CHS

12"

CHR

10"

CHS10"

CHR

52-P-4

52-P-1

C H S

C H R

EX 52-CH-2

52-CH-1

EX 52-P-5

EX 52-P-2

52-CH-3

12"

CHR

10"

CHS

10"

CHR

16" CHS

16" CHS

16" CHR

16" CHS

16" CHS16" CHS

16" CHR

12" CHR 16" CHS

16" CHR

12" CHR

16" CHR

16" CHS

16" CHR

16" CHS

C H R

C H S

C H R

C H R12

C H S

C H S

C H S

12" CHS

12" CHS

12" CHS

12" CHR

52-P-12

52-P-6

C H S

12"

CHS

52-P-4

52-P-1

C H R

C H S

C H R

C H R

C H S

C H R

EX 52-P-2

EX 52-P-5

52-CH-1

EX 52-CH-2

52-CH-3

52-CH-2

52-CH-1

52-FPHX-1

52-P-12

52-P-2

52-P-3

52-P-1

52-P-4

52-P-5

52-P-6

12" CHS

12" CHS

12" CHS

12" CHR

16" CHS

16" CHS

16" CHS

C H S

C H S

C H S

C H R

C H R

C H R

C H R

C H R

C H R

C H S

16" CHR

16" CHS

16" CHS16" CHR

16" CHS

16" CHR

12" CHR

12" CHR

16" CHR

16" CHS

16" CHS

16" CHR

12"

CHR

10"

CHS10"

CHR

12"

CHS

12" CHR

12" CHR

12" CHS

12" CHS 10" CHR

C H R

C H R

C H R

C H R

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:5

:4

P

M

M-905

CHILLED W ATER PIPING ISOMETRIC VIEW S -

PHASE 3 AND PHASE 4

46 48AKS, WRS

UPGRADE CHILLER PLANT

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

RBK

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale:

CHILLED WATER PIPING DEMOLITION - PHASE 3

Scale:

CHILLED WATER PIPING NEW WORK - PHASE 3

Scale:

CHILLED WATER PIPING DEMOLITION - PHASE 4

Scale:

CHILLED WATER PIPING NEW WORK - PHASE 4

DocuSign Envelope ID: B32A6B38-868E-4D60-B593-FDD61A5FDCEC

2/23/2021

EX 52-P-8

EX 52-P-7

EX 52-CH-1

EX 52-CH-2

EX 52-FPHX-1

EX 52-CH-3

EX 52CT-1A

EX 52CT-1B

EX 52CT-2A

EX 52CT-2B

EX 52CT-3

20" CWR

20" CWR

20" CWR

20" CWR

C W R

20" CWS

C W R

C W R

20" CWS

20" C

WS

C W S

C W S

C W S

C W S

C W R

C W S

CW

R

C W R

C W S

C W R

C W S

C W R

12" CWR

C W S

EX 52P-13

8" CWR

8" CWR

8" CWR

8" CWR

8" CWR

8" CWR

8" CWR

8" CWR

8" CWR

8" CWR

10" CWR

10" CWR

10" CWR

10" CWR

10" CWR

14" CWR

52-CT-1

52-CT-2

EX 52CT-3

8" CWR

8" CWR

10" CW R

8" CWR

10" CW R

8" CWR

8" CWR

10" CW R

8" CWR

8" CWR

10" CW R

52-WT-4

52-WT-3

52-WT-2

52-WT-1

8" CWR

10" CWR

8" CWR

20" CWR

20" CWS

C W S

C W S

12" CWR

14" CWR

C W S

C W S20" C

WS

20" CWR

20" CWS

C W S

C W R

20" CWR

C W S

C W R

20" CWS

20" CWS

20" CWR

CW

R

C W S

EX 52P-13

20" CWR

14" CW R

14" CWS

52-P-7

52-P-8

C

W

S 10" CWS

10" CWS

EX 52-CH-1

EX 52-CH-2

EX 52-CH-3

10" CWS

20" CWR

52-CT-1

8" CWR

10" CWR

8" CWR

8" CWR

10" CWR

8" CWR

52-CT-2

8" CWR

10" CWR

8" CWR

8" CWR

10" CWR

52-WT-4

52-WT-3

52-WT-2

52-WT-1

EX 52CT-3

8" CWR

10" CWR

8" CWR

20" CWR

20" CWS

20" CWR

20" CWR

20" CWS

20" CWR

20" CWR

20" CWS

20" C

WS

14" CWR

C W S

C W S

C W S

C W S

C W R

C W S

C W S

C W S

C W R

C W R10

C W S

52-P-8

52-P-7

C W S

EX 52-CH-1

EX 52-CH-2

EX 52-CH-3

EX 52P-13

C W S

14" CWR

14" CWS

12" CWR

20" CWR

52-CT-1

8" CWR

10" CWR

8" CWR

8" CWR

10" CWR

8" CWR

52-CT-2

8" CWR

10" CWR

8" CWR

8" CWR

10" CWR

8" CWR

52-CT-3

20" CWR

20" CWR

20" CWR

20" CWR

20" CWS

20" CWS

20" CWS

20" C

WS

C W S

14" CWR

C W S

C W S

C W S

12" CWR

C W S

C W R

C W S

C W R

52-P-7

52-P-8

52-P-13

C W S

C W S

C W S

EX 52-CH-1

EX 52-CH-2

52-CH-3

14" CWR

14" CWS

20" CWR

14" EQL

14" EQL

14" EQL

52-WT-5

52-WT-6

C

W S

C

W S

10" CWS

C

W R

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:5

:4

P

M

M-906

CONDENSER W ATER PIPING ISOMETRIC

VIEW S - PHASE 1 AND PHASE 2

47 48AKS, WRS

UPGRADE CHILLER PLANT

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

RBK

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale:

CONDENSER WATER PIPING DEMOLITION - PHASE 1

Scale:

CONDENSER WATER PIPING NEW WORK - PHASE 1

Scale:

CONDENSER WATER PIPING DEMOLITION - PHASE 2

Scale:

CONDENSER WATER PIPING NEW WORK - PHASE 2

52-CT-1

8" CWR

10" CWR

52-WT-1

8" CWR

10" CWR

52-WT-2

8" CWR

8" CWR

52-CT-2

8" CWR

10" CWR

52-WT-3

8" CWR

8" CWR

10" CWR

8" CWR

52-WT-452-CT-3

52-P-7

52-P-8

52-P-13

EX 52-CH-1

EX 52-CH-2

52-CH-3

C W S

C W S

C W S

12" CWR

14" CWR

20" CWR

20" CWR

20" CWR

20" CWR

20" CWS

20" CWS

20" C

WS

C W S

C W S

C W S

C W S12

C W R

C W S

C W R

14" CWR

14" CWS

20" CWR

14" EQL

14" EQL

14" EQL

C W R

10" C

WS

C W R

14" EQL

14" EQL

8" CWR

8" CWR

8" CWR

8" CWR

10" CWR

10" CWR

52-CT-1

8" CWR

10" CWR

8" CWR

52-WT-1

8" CWR

10" CWR

52-WT-2

8" CWR

52-CT-2

8" CWR

10" CWR

52-WT-3

8" CWR

52-CT-2

8" CWR

10" CWR

52-WT-4

8" CWR

52-CT-3

52-P-7

52-P-8

52-P-13

52-CH-3

10" CWS

20" CWR

20" CWS

20" CWR

20" CWS

20" CWR

20" CWS

20" CWR

20" C

WS

C W S

C W S

C W S

C W S

C W S

C W S

C W S

14" CWR

12" CWR

C W

S14" CWR

14" CWS

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

10" CWR

8" CWR

8" CWR

C W S

10" C

WS

C W R

8" CWR

10" CWR

8" CWR

EX 52-CH-2

52-CH-1

52-CT-1

8" CWR

10" CWR

8" CWR

52-WT-1

8" CWR

10" CWR

52-WT-2

52-CT-2

8" CWR

10" CWR

52-WT-3

8" CWR

8" CWR

10" CWR

52-WT-4

52-CT-3

52-P-7

52-P-8

52-P-13

52-CH-3

20" CWS

20" CWR

20" CWR

20" CWS

20" CWR

20" CWS

20" CWR

20" C

WS

C W S

14" CWR

C W S

C W S

C W S

12" CWR

C W S

C W R

C W S

C W S

C W S

10" CWS

14" CWR

14" CWS

20" CWR

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

10" C

WS

C W R

8" CWR

8" CWR

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

8" CWR

10" CWR

8" CWR

10" CWR

8" CWR

EX 52-CH-2

52-CH-1

52-CT-1

8" CWR

10" CWR

52-WT-1

8" CWR

8" CWR

10" CWR

52-WT-2

8" CWR

52-CT-2

8" CWR

10" CWR8" CWR

10" CWR

8" CWR

52-WT-4

C W S

12" CWR

C W S

C W S

C W S

20" C

WS

14" CWR

20" CWR

20" CWS

20" CWR

C W R

10" CWS

C W S

CW

R

20" CWS

20" CWR

20" CWR

20" CWS

10" CWS

10" CWS

14" CWR

14" CWS

52-CH-3

52-CH-2

52-CH-1

52-FPHX-1

52-P-13

52-P-8

52-P-7

C W S

C W S

C W S

C W S

C W R

C W R

10" CWR

52-CT-3

20" CWR

C W R

C W S

C W S

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL

14" EQL 14" EQL

8" CWR

8" CWR

8" CWR

10" CWR

8" CWR

10" CWR

8" CWR

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:5

:5

P

M

M-907

CONDENSER W ATER PIPING ISOMETRIC

VIEW S - PHASE 3 AND PHASE 4

48 48AKS, WRS

UPGRADE CHILLER PLANT

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

RBK

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

Scale:

CONDENSER WATER PIPING DEMOLITION - PHASE 3

Scale:

CONDENSER WATER PIPING NEW WORK - PHASE 3

Scale:

CONDENSER WATER PIPING DEMOLITION - PHASE 4

Scale:

CONDENSER WATER PIPING NEW WORK - PHASE 4

L L

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSW SELECTOR SWITCH

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TC TIMECLOCK

TEL TELEPHONE

TEL/DATA TELEPHONE/DATA

TERM TERMINAL

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL

CABINET

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORY

UT UNDERGROUND TELEPHONE

UTP UNSHIELDED TWISTED PAIR

UTIL UTILITY

UV UNIT VENTILATOR OR

ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

ANGLE

@ AT

DELTA

' FEET

" INCHES

# NUMBER

Φ PHASE

C CENTER LINE

P PLATE

MTR MOTOR, MOTORIZED

MTS MANUAL TRANSFER SWITCH

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY DISCONNECT

SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OL OVERLOAD

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT

UNIT

PCB POLYCHLORINATED BYPHENYL

PC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

POE POWER-OVER-ETHERNET

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QTY QUANTITY

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SF SQUARE FEET/FOOT

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

1P 1 POLE (2P, 3P, 4P, ETC.)

1PH 1 PHASE

2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)

W2 TWO-WIRE (3W, 4W, ETC.)

3PH 3 PHASE

A AMPERE

AAP ALARM ANNUNCIATOR PANEL

AC ABOVE COUNTER

AIR CONDITIONER

ALTERNATING CURRENT

ACC ACCESSIBLE

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

A/E ARCHITECT/ENGINEER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT (KILOAMPS)

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

APPROX APPROXIMATELY

ARCH ARCHITECT, ARCHITECTURAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISHED FLOOR

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATED

CAP CAPACITY

CAT CATALOG, CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR-FURNISHED

CKT CIRCUIT

CLG CEILING

CO CONTRACTING OFFICER

COAX COAXIAL CABLE

COMM COMMUNICATION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CTR CENTER

CU COPPER

CU FT CUBIC FEET

dB DECIBEL

DB DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLISH/DEMOLITION

DEPT DEPARTMENT

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOWN

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

EG EQUIPMENT GROUND

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EPO EMERGENCY POWER OFF

EQUIP EQUIPMENT

ESMT EASEMENT

ETR EXISTING TO REMAIN

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WALL HEATER

ELECTRIC WATER HEATER

EX EXISTING

EXP EXPLOSION PROOF

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT SWITCH

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

GRS GALVANIZED RIGID STEEL (CONDUIT)

GYP BDGYPSUM BOARD

HID HIGH-INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

IES ILLUMINATION ENGINEERING SOCIETY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

I/W INTERLOCK WITH

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LED LIGHT-EMITTING DIODE

LF LINEAR FEET/FOOT

LM LUMEN

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

METAL-CLAD (CONDUIT)

MCA MINIMUM CIRCUIT AMPACITY

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT SWITCH

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MOA MULTIOUTLET ASSEMBLY

MSBD MAIN SWITCHBOARD

MT MOUNT

A1 b

E1 c d

T1

'LPN'

THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER CASE LETTER

AND NUMBER.

THE SWITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.

EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b' (IF SWITCH

IS LABLED EM, THE FIXTURE IS CIRCUITED TO AN EMERGENCY CIRCUIT).

EXIT SIGNS: STEM INDICATES WALL MOUNTING. NO STEM INDICATES CEILING MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES DIRECTIONAL ARROW ON ILLUMINATED

FACE(S).

DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER FOLLOWING THE UPPER

CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR THE SINGLE LINE DIAGRAM FOR THE

TRANSFORMER DESCRIPTION AND REQUIREMENTS.

PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING SIDE OF RECESSED

PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR DESIGNATION CODES.

SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE NUMBER INDICATED

IN THE HEXAGON.

HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT DESIGNATION ARE

SHOWN ADJACENT TO THE HOME RUN ARROW.

CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL SCHEDULE WITH

THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.

SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE A UNIT TYPE. SEE

APPROPRIATE SCHEDULE OR SPECIFICATIONS.

'LPN'-1,3,5

EXAMPLE 1: WALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE AND DIRECTIONAL

ARROW.

EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' WITH DOUBLE FACE AND DIRECTIONAL

ARROWS.

E2

EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS

CONTROLLED BY SWITCH 'c'.

EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING FIXTURES INDICATED BY 'd'.

EXAMPLE: TRANSFORMER TYPE 'T1'.

EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.

# DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE NUMBER

INDICATED IN THE SQUARE.

2' X 2' RECESSED DIRECT/INDIRECT TROFFER

2' X 4' RECESSED DIRECT/INDIRECT TROFFER

SYMBOL

HEIGHT

AFF * DESCRIPTION

--- 2' X 4' RECESSED FLAT PRISMATIC LENS TROFFER

WALL SCONCE

6'-0"

CENTER

6" DIAMETER RECESSED DOWNLIGHT---

EXIT SIGN - WALL MOUNTED

EXIT SIGN - CEILING MOUNTED---

7'-5"

BOTTOM

SINGLE POLE WALL SWITCH

SWITCH MODIFIERS:

OS: OCCUPANCY SENSOR, DUAL TECHNOLOGY

VS: VACANCY SENSOR, DUAL TECHNOLOGY

LV: LOW VOLTAGE

LVD: LOW VOLTAGE DIMMER

D: LINE VOLTAGE DIMMER

T: DIGITAL TIMER

K: KEYED

3: 3 WAY

48"

CENTER

OCCUPANCY SENSOR, DUAL

TECHNOLOGY - CEILING MOUNTED

--- LOW VOLTAGE LIGHTING CONTROL DEVICE

OCCUPANCY SENSOR, DUAL

TECHNOLOGY - WALL/CORNER MOUNTED

2' LINEAR - WALL MOUNTED

7'-0"

CENTER

EMERGENCY LIGHT BATTERY

OPERATED - WALL MOUNTED

7'-6"

CENTER

RC

* - ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE

LISTED HERE.

LIGHT LEVEL SENSOR, SINGLE ZONE

DIMMING CLOSED LOOP - CEILING MOUNTED

--- LOW VOLTAGE LIGHTING CONTROL

DEVICE WITH 0-10V DIMMING

RCD

4' LINEAR - WALL MOUNTED

7'-0"

CENTER

OS

OS

LS

A. PHASE 1

1. INSTALLATION OF NEW PANELS "HM1", "HM2", "HM3", "HM4", & “LCT2”, INCLUDING ASSOCIATED FEEDERS.

a. REPLACE EXISTING 800A, 3P CIRCUIT BREAKER IN SUBSTATION #1 TO FEED PANEL “HM1”.

b. SPLICE-IN NEW PANEL “HM2” FEEDERS TO EXISTING MCC-1 FEEDERS INSIDE SUBSTATION #1

DISTRIBUTION SWITCHBOARD.

c. INSTALL PANEL “HM4”, INCLUDING ASSOCIATED FEEDERS TO SPARE 800A, 3P CIRCUIT BREAKER IN

SUBSTATION #4.

d. INSTALL NEW PANEL “LCT2” VIA NEW TRANSFORMER, INCLUDING ASSOCIATED FEEDERS AND

CONNECT TO SPARE CIRCUIT BREAKER IN SUBSTATION #4.

2. PROVIDE TEMPORARY FEEDERS FOR TEMPORARY COOLING TOWERS AND CONNECT TO NEW PANEL

“HM1” OR PANEL “HM2”.

3. DISCONNECT/REMOVE EXISTING COOLING TOWERS CT-1 AND CT-2, INCLUDING ASSOCIATED FEEDERS.

4. PROVIDE NEW BRANCH CIRCUIT FEEDERS TO THE FOLLOWING HVAC EQUIPMENT AND CONNECT TO

PANELS

INDICATED BELOW:

a. PANEL “HM1” : 52-P-1, 52-P4, 52-P-7, EXIST. 52-P-13 (TEMPORARY CONNECTION), NEW 52-P-13 CT-1, CT-1 BASIN HEATERS, 52-AHU-1, AND 52-AHU-2.

b. PANEL “HM2” : 52-EF-1, 52-EF-2, AND 52-EF-3

c. PANEL “HM4” : 52-P-3, 52-P-8, 52-P-14, CT-2, AND CT-2 BASIN HEATERS

5. DISCONNECT AND REMOVE MCC-1, INCLUDING ASSOCIATED FEEDERS AND ALL CONNECTED BRANCH

CIRCUIT WIRING.

6. TERMINATE PANEL “HM2” FEEDERS TO 800A, 3P CIRCUIT BREAKER VACATED BY MCC-1.

7. INSTALL VFD’S FOR COOLING TOWERS AT FORMER MCC-1 LOCATION.

8. PREPARE A TEMPORARY FEEDER CHILLER #1 TO THE CUBICLE SERVING CHILLER #3. TERMINATE BOTH

ENDS OF THE FEEDER PRIOR TO DISCONNECTING ANY POWER. DISCONNECT CHILLER #3 AND

TERMINATE THE TEMPORARY FEEDERS.

9. DURING A WEEKEND OUTAGE AT NIGHT DISCONNECT CHILLER #1 AND RECONNECT IT TO THE TEMPORARY FEEDER. OUTAGE TO BE LIMTED TO 1 HOUR OR LESS AND MUST OCCUR WHEN CHILLER

PLANT DEMAND LESS THAN 800 TONS.

10. REMOVE SUBST. #2 TRANSFORMER & DISTRIBUTION SECTIONS, 15KV SELECTOR SWITCH SHALL REMAIN.

INSTALL NEW SUBSTATION #2 TRANSFORMER & DISTRIBUTION SECTIONS. COMMISSION SECONDARY

DISTIBUTION OF SUBSTATION #2

11. INSTALL NEW FEEDER BUSWAYS FOR NEW CHILLERS #1, #3, & CROSS CONNECTION TO TEMPORARY

CHILLER DISCONNECT TO NEW SUBST. #2.

12. PROVIDE TEMPORARY FEEDERS FOR CRITICAL EQUIPMENT BEFORE ELECTRICAL SHUTDOWN.

a. TEMPORARY CONNECT 52-P-5 TO MCC-EQB.

b. TEMPORARY CONNECT EM LIGHTING CIRCUIT TO MCC-EQB.

c. TEMPORARY CONNECT LIGHTING AND POWER OF PLANT CONTROL ROOM (ENGINEERING

OFFICE-106) TO MCC-EQB.

d. TEMPORARY CONNECTION OF AHU-1 TO MCC-EQB.

13. PROVIDE TEMPORARY LIGHTING FOR EQUIPMENT THAT IS IN OPERATION DURING THE ELECTRICAL

SHUTDOWN FOR EMERGENCY MAINTENANCE.

14. INITIATE/PROVIDE ELECTRICAL SHUTDOWN TO THE CHILLER PLANT FOR THE REPLCEMENT OF THE 15 KV SWITCH ASSOCIATED WITH UNIT SUBSTATION #2 (EC TO VERIFY WITH MC THAT TEMPORARY CHILLER IS

WORKING AS INTENDED AND OPERATIONAL THROUGH THE SHUTDOWN BEFORE POWER OUTAGE).

OUTAGE TO BE LIMTED TO 12 HOURS AND OCCUR ON A FRIDAY NIGHT STARTING AT 9PM. THIS OUTAGE

WILL REMOVE POWER TO THE ENTIRE CHILLER PLANT.

a. REPLACE EXISTING SUBSTATION #2 15KV SELECTOR SWITCH WITH THE NEW SUBST. #2 15KV

SELECTOR SWITCH AND CONNECT TRANSFORMER/DISTRIBUTION SECTIONS TO 15KV SELECTOR

SWITCH. PERFORM FINAL COMMISSIOING OF SUBSTATION.

B. PHASE 2

1. CONNECT NEW CHILLER #3 TO SUBST. #2 BY THE NEW FEEDER BUSWAY.

2. PROVIDE NEW BRANCH CIRCUIT FEEDERS TO THE FOLLOWING HVAC EQUIPMENT AND CONNECT TO

PANEL

“HM2”: 52-P-6, 52-P-12, 52-P-13, CT-3, AND CT-3 BASIN HEATERS

C. PHASE 3

1. DISCONNECT EXISTING CHILLER #1 FROM SUBSTATION #3.

2. CONNECT NEW CHILLER #1 TO SUBSTATION #2 BY THE NEW FEEDER BUSWAY.

D. PHASE 4

1. INITIATE/PROVIDE ELECTRICAL SHUTDOWN OF THE CHILLER PLANT TO DISCONNECT POWER TO SUBSTATION #3. DISCONNECT FEEDERS TO SUBSTATION #3 AT SUBSTATION #4. RESTORE POWER TO THE CHILLER PLANT. OUTAGE TO BE LIMTED TO 1 HR. OUTAGE TO OCCUR AT NIGHT DURING A WEEKEND.

2. REPLACE EXISTING SUBST. #3 WITH NEW.

3. INITIATE/PROVIDE ELECTRICAL SHUTDOWN OF THE CHILLER PLANT TO RECONNECT POWER TO

SUBSTATION #3. RECONNECT FEEDERS TO SUBSTATION #3 AT SUBSTATION #4. RESTORE POWER TO THE CHILLER PLANT. OUTAGE TO BE LIMTED TO 1 HR. OUTAGE TO OCCUR AT NIGHT DURING A WEEKEND.

4. INSTALL CHILLER #2 FEEDERS AND CONNECT NEW CHILLER #2 TO NEW SUBSTATION #3

5. CONNECT NEW PANEL “HM3”, INCLUDING ASSOCIATED FEEDERS AND CONNECT TO SUBSTATION #3.

6. PROVIDE NEW BRANCH CIRCUIT FEEDERS TO THE FOLLOWING HVAC EQUIPMENT AND CONNECT TO

PANEL

"HM3": 52-P-2, 52-P-5, 52-EF-4, 52-EF-5, 52-EF-6, 52-EF-7, AND 52-SF-1

7. DISCONNECT AND REMOVE MCC-3, INCLUDING ASSOCIATED FEEDERS AND ALL CONNECTED BRANCH

CIRCUIT WIRING.

GENERAL ELECTRICAL NOTES

1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN

ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED

PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND

WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VA STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE

BUILDING CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL

PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE

WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND

THE APPLICABLE BUILDING CODES.

4. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.

5. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.

6. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO

AVOID CONFLICT DURING CONSTRUCTION.

7. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR

SPARE, OR SPACE.

8. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO

INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR

MANUFACTURER. PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE

ACCEPTED. ALL PRODUCTS MUST COMPLY WITH "BUY AMERICAN ACT".

9. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR

EQUIPMENT MANUFACTURER'S SPECIFICATIONS.

10. CIRCUITRY TO SWITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE

DEVICE'S SCREW TERMINALS.

11. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT

UNLESS NOTED OTHERWISE.

12. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

13. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

14. ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND

CONDUIT OR WHERE CONCRETE-ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE,

LFMC CONDUIT SHALL BE USED (MAXIMUM SIX FEET) FOR FINAL CONNECTIONS.

15. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN

APPROVED THIRD PARTY TESTING AGENCY.

16. FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE

SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC

PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE

MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT

BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY.

PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

17. IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE

BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS

DETERMINED BY THE GOVERNMENT, SHALL BE PROVIDED.

18. COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.

19. THE TERMS "MOTOR CONTROLLER" AND "MOTOR STARTER" ARE BOTH USED IN THESE PLANS. BOTH TERMS SHALL BE CONSIDERED TO MEAN THE SAME THING, WHICH IS THE MOTOR CONTROLLER AS

DESCRIBED IN THE NATIONAL ELECTRICAL CODE.

20. FOR NEW MECHANICAL AND ELECTRICAL EQUIPMENT TO BE PROVIDED AND INSTALLED UNDER THIS

PROJECT, SEE SHEET E-607 FOR CONDUCTOR AND RACEWAY TYPES AND SIZES, FOR MOTOR

CONTROLLER REQUIREMENTS, AND FOR OTHER INSTALLATION REQUIREMENTS. EC SHALL PROVIDE

POWER WIRING. MC SHALL PROVIDE CONTROL WIRING. LIGHTING FIXTURE SCHEDULE

A. MANUFACTURER AND CATALOG NUMBERS SHOWN ARE FOR BASIS OF DESIGN, DESCRIPTIVE AND QUALITY STANDARDS ONLY, NOT TO BE USED FOR ORDERING WITHOUT VERIFICATION AND APPROVAL. CONTRACTOR TO PROVIDE PRODUCT OR EQUAL FOR APPROVAL BY OWNER, ARCHITECT AND ENGINEER. ENGINEER SHALL NOT BE RESPONSIBLE

FOR MISMATCHED OR INACCURATE PART NUMBERS.

B. VERIFY ALL LIGHT FIXTURE MOUNTING TYPES AND COLORS WITH ARCHITECT.

C. FOR ALL LED FIXTURES, THE FIXTURE SHALL BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, SHALL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY. PROVIDE STATEMENT WITH THE FIXTURE

SUBMITTALS.

D. LIGHTING CONTROLS, INCLUDING CONTROL SCHEMATICS, DEVICES, SWITCHES, SENSORS AND GRAPHIC DISPLAYS/CONTROLLERS. THIS INFORMATION MUST BE SUBMITTED WITH

THE LIGHT FIXTURE SHOP DRAWINGS, FOR A COMPLETE REVIEW.

E. PROVIDE SPECIAL DRILLING AND BACKING AS REQUIRED FOR MOUNTING A 24” LIGHTNING PROTECTION SYSTEM AIR TERMINAL TO PROJECT UP FROM THE TOP OF EACH LIGHT POLE. POLE SHALL HAVE ENTRY HOLE AT THE TOP FOR ENTRY OF LIGHTNING PROTECTION SYSTEM DOWN-CONDUCTOR, AND SHALL HAVE ACCESSIBLE GROUND CONNECTION BUSHINGS INSIDE THE POLE AT THE TOP AND AT THE BOTTOM FOR BONDING CONNECTION OF DOWN-CONDUCTOR TO THE TOP AND THE BOTTOM OF EACH POLE.

GENERAL NOTES:

SYMBOL

HEIGHT

AFF * DESCRIPTION

120V DUPLEX RECEPTACLE18"

18"

18"

18"

18"

18"

R S

H

T

L

VS

E

VFD

J

AS NOTED

72" TOP

72" TOP

72" TOP

AS NOTED

48"

120V DUPLEX RECEPTACLE EMERGENCY OUTLET AND

COVER PLATE SHALL BE RED IN COLOR

120V QUADRUPLEX RECEPTACLE

120V QUADRUPLEX RECEPTACLE EMERGENCY OUTLET

AND COVER PLATE SHALL BE RED IN COLOR

208V DUPLEX RECEPTACLE

120V DUPLEX RECEPTACLE FLOOR BOX

120V QUADRUPLEX RECEPTACLE FLOOR BOX

120V DUPLEX RECEPTACLE EMERGENCY FLOOR BOX

OUTLET AND COVER PLATE SHALL BE RED IN COLOR

SPECIAL RECEPTACLE

120V QUADRUPLEX RECEPTACLE EMERGENCY FLOOR

BOX OUTLET AND COVER PLATE SHALL BE RED IN

COLOR

RECEPTACLE MODIFIERS:

AC: 3" ABOVE COUNTERTOP/BACKSPLASH

GFI: GROUND FAULT CURRENT INTERRUPTER

WP: WEATHERPROOF ENCLOSURE

DED: DEDICATED CIRCUIT

AUDIBLE/VISUAL REFRIGERANT LOSS ALARM

BASIN WATER HEATER

BASIN WATER HEATER THERMOSTAT

LOW WATER LEVEL SHUDOWN SENSOR

VIBRATION SHUTDOWN SWITCH

MOTOR

EQUIPMENT CONNECTION

PANELBOARD

DISCONNECT SWITCH NON-FUSED

DISCONNECT SWITCH FUSED

JUNCTION BOX

LIGHTNING PROTECTION AIR TERMINAL

LIGHTNING PROTECTION EXOTHERMIC WELD -

GROUND

COMBINATION MOTOR STARTER WITH INTERGRAL

DISCONNECT AND OVER-CURRENT PROTECTION

VARIABLE FREQUENCY DRIVE (VFD) MOTOR

CONTROLLER WITH INTERGRAL DISCONNECTING DEVICE

SINGLE POLE WALL SWITCH

SWITCH MODIFIERS:

M: MOTOR RATED

ALL HEIGHTS ARE TO CENTER OF DEVICE UNO.

TOP: HEIGHT TO TOP OF DEVICE

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:0

:2

P

M

E-001

ELECTRICAL GENERAL NOTES, SYMBOL

LEGENDS, AND ABBREVIATIONS

1 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

ELECTRICAL ABBREVIATIONS LIST

ELECTRICAL SYMBOL NOTES

LIGHTING SYMBOL LEGEND

ELECTRICAL WORK SEQUENCING PLAN

TYPE DESCRIPTION MOUNTING LAMP DRIVER VOLTAGE WATTS MANUFACTURER MODEL NUMBER

- 1' X 4' DIRECT/INDIRECT TROFFER; CHAIN

SUSPEND

EXISTING EXISTING 277 V 30 W EXISTING -

A1 4' LINEAR LED STRIPLIGHT WITH LENS CHAIN

SUSPEND

LED; 5000 LUMENS;

80 CRI; 4000K

ELECTRONIC LED

DRIVER

277 V 50 W EATON 4SNLED-LD5-44SL-LW-UNV-L840-CD

A2 4' LINEAR LED STRIPLIGHT WITH LENS CHAIN

SUSPEND

LED; 5000 LUMENS;

80 CRI; 4000K

ELECTRONIC LED

DRIVER

277 V 50 W EATON 4SNLED-LD5-56SL-LW-UNV-L840-CD1

B1 4' LINEAR LED STRIPLIGHT WITH LENS CHAIN

SUSPEND

LED; 5000 LUMENS;

80 CRI; 4000K

ELECTRONIC LED

DRIVER

277 V 50 W EATON 8TSNLED-LD5-88SL-LW-UNV-L840-CD1

B2 4' LINEAR LED STRIPLIGHT WITH LENS CHAIN

SUSPEND

LED; 5000 LUMENS;

80 CRI; 4000K

ELECTRONIC LED

DRIVER

277 V 50 W EATON 8TSNLED-LD5-110HL-LW-UNV-L840-CD1

C 2' X 2' DIRECT/INDIRECT TROFFER; RECESSED

GRID

LED; 3400 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE TO

5% DRIVER

277 V 30 W EATON 22CZ-LD5-34-S-UNLV-L835-CD1-U

D SINGLE HEAD RECTANGULAR FULL CUTOFF SHOEBOX,

DARK BRONZE FINISH, TYPE IV DISTRIBUTION, HOUSE

SIDE SHEILD, UL LISTED FOR WET LOCATION,

MOUNTED ON 25'-0" ROUND TAPERED STEEL POLE.

POLE LED; 4836 LUMENS;

80 CRI; 4000K

ELECTRONIC LED

DRIVER

277 V 65 W KIM

VALMONT POLE

1SA-SAR4-E35-60L-4K-208-DB-SF-LS-NFO-TL

DS210-590A250-D1-PC-FP-DB-NC-AB (CUSTOM

CUT STANDARD 25-FOOT POLE TO

ALLOW FOR 22-FOOT FIXTURE MOUNTING

HEIGHT.)

ETR CONTEMPORARY LED SINGLE FACED EXIT SIGN WITH

BLACK POWDER PAINT ALUMINUM HOUSING,

BRUSHED ALUMINUM FACE, RED LETTERS, AND

CHEVRON ARROWS AS SHOWN ON PLANS.

UNIVERSAL LED --- 120 V 5 W EXISTING

ELECTRICAL SYMBOL LEGEND

DocuSign Envelope ID: EC584823-3079-447F-BB84-1D8AD0835F75

7A

7A

7A

7A 7A

7A

7A

7B

7B

7BA

7BF

7BA

7B

7A

7BF

5A

5A

5B

AB

AB

5B

5B

5B

5A5A

5A 5A

5A

5A

5B

5B

5B

5B

5B

MVG

MV FEEDER #5

ABANDONED / CUT IN

MANHOLE 2A

EXISTING DUCT,

UNKNOWN IF USABLE

4A

4A

4A

4A

4B

4BE

4BC

4B

4B

4BA

4BA

4BF

4A

4A

4B

4A

4BC

4BF

H O N O R

H E

IG

H T S

D R

IV

E

B U F F A L O

D R

IV

E

P A R K

D R

IV

E

18 11

1A

1B

1E

1C

G

G

G

E

GGENERATORS -

FEEDER #4

TRANSFORMERS -

MANHOLES -

FEEDER #5

FEEDER #7

59T

G

G G

FEEDER #9

FEEDER #8

#7

#1

#2

#2A

#9

#8

#4

#10

#2A

OG&E

E

K

M

LJ P

N

O

USS 3

USS 4

USS 2 USS 1

ATS-SA

USS "I"

USS 5

USS 6

USS 7

XFMR A

XFMR FGENERATORS 46 A & B

SEC. CABINET MV4

XFMR E

XFMR D

XFMR B

GENERATORS 56 1 & 2

GENERATOR 18

GENERATORS SG-4

ATS SG-4

GENERATOR 52

12,470v / 1.25 MVA

XFMR C

#3

PRIMARY SWITCHGEAR BUILDING

EXISTING MEDIUM VOLTAGE

DISTRIBUTION SYSTEM MAIN

SWITCHGEAR BUILDING #54

PROJECT LOCATION,

CHILLER PLANT

BUILDING #52

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:0

:2

P

M

ES101

ELECTRICAL SITE PLAN

2 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

NORTH

0 5025 100

Scale: 1" = 50'-0"

ELECTRICAL SITE PLAN

A. THIS DRAWING DIAGRAMS THE EXISTING VA

MEDICAL CENTER CAMPUS MEDIUM VOLTAGE

ELECTRICAL POWER DISTRIBUTION SYSTEM

FOR REFERENCE ONLY AND IT IDENTIFIES THE

PROJECT LOCATION, CHILLER PLANT BUILDING

52. NO NEW WORK IS SHOWN ON THIS SHEET.

1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7

S U B

S U B

F R O N T

T

T

S U B

F R O N T

T

4 F R O N T

S U B

V F

D V

F D

V F

D

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

TO CT-#3,

CELL #5

TO COOLING

TOWER SEPARATOR

TO PUMP 52P-13 ON

MEZZANINE

03 03

(EX) MV MOTOR CONTROLLER

FOR CHILLER #2

01 01 01

TO BASIN HEATERS,

CT-#3, CELL #5

'MCC-2' - 7A

'MCC-2' - 8E

'MCC-2' - 9A

'MCC-1' - 1S

'MCC-1' - 3E

'MCC-1' - 5U

'MCC-2' - 3M

(ETR) PANEL 'HCT'

(ETR) PANEL 'DP1C'

(ETR) TRANSFORMER 'TA'

(ETR) PANEL 'LCT'

(ETR) PANEL 'EQLCP'

(ETR) TRANSFORMER

(ETR) TRANSFORMER

(ETR) PANEL 'ECHCP'

(ETR) ATS-ECB

(ETR) SUB #1

(EX) SUB #2

(ETR) SUB #4

(ETR) ATS-EQB

(ETR) MCC EQB

(ETR) ATS-SA

(EX) MCC -2 (EX) MCC -1

(EX) SUB #3

(EX) MV MOTOR CONTROLLER

FOR CHILLER #1

(EX) MV MOTOR CONTROLLER

FOR CHILLER #2

'MCC-2' - 3A

CHILLER #3

CONTROL PANEL

UP TO EF-5 ON

MEZZANINE SEE

SHEET ED103

'MCC-2' - 1A

CHILLER #2

CONTROL PANEL

CHILLER #1

CONTROL PANEL

'MCC-2' - 2G

'MCC-1' - 7J

'MCC-2' - 7M

'MCC-2' - 7M03 03

(EX) PUMP CONTROLLER

(ETR)

VFD 52-P-11

(EX)

VFD 52-P-2

(EX)

VFD 52-P-3

(EX)

VFD 52-P-9

'MCC-1' - 2A

'ECHCP' - 7,9,11

V F D

(ETR)

'EQLCP'-28

(EX)

VFD 52-P-10

(EX)

VFD 52-P-1

XFMR

(ABOVE)

XFMR

(FLOOR

MOUNT)

(ETR) PUMP CONTROLLER

52-CTSSF-1

52-EF-1

(ABOVE)

EX 52-P-6EX 52-P-5EX 52-P-4EX 52-P-1

EX 52-P-8

EX 52-P-2EX 52-P-3

EX 52-P-12

EX 52-EF-2EX 52-EF-7

EX 52-P-9

EX 52-P-10

EX 52-P-11

EX 52-CH-3 EX 52-CH-2 EX 52-CH-1

EX 52-P-7 (ETR)

(ETR)

(ETR)

EX 52-P-14

(ETR) PANEL

'PDP-52HT'

EX 52-LA-9

EX 52-LA-12A1

EX 52-LA-12A2

EX 52-LA-12B1

EX 52-LA-12B2

EX 52-LA-1

EX 52-LA-6

EX 52-LA-5

EX 52-LA-2

04 04

ENGINEERING OFFICE

TOILET

CHILLER PLANT

WATER SAMPLING

STORAGE

TRANSFORMER VAULT

TRANSFORMER VAULT

CHILLER PLANT

Engineers Architects

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:4

P

M

ED101

FIRST FLOOR ELECTRICAL DEMOLITION

PLAN

3 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

FIRST FLOOR ELECTRICAL DEMOLITION PLAN

01 DISCONNECT POWER FEEDER FROM

INDICATED 4,160V CHILLER TO BE REPLACED

BY MC. REMOVE INDICATED 5KV FEEDER

CONDUCTORS AND RACEWAYS BACK TO

SOURCE.

02 DISCONNECT POWER FEEDER FROM

INDICATED 4,160V CHILLER MOTOR

CONTROLLER TO BE REPLACED BY MC.

REMOVE INDICATED 5KV FEEDER

CONDUCTORS AND RACEWAYS BACK TO

SOURCE.

03 DISCONNECT POWER FEEDER FROM

INDICATED 460V MOTOR TO BE REPLACED BY

MC. REMOVE INDICATED FEEDER

CONDUCTORS AND RACEWAYS BACK TO

SOURCE.

04 DISCONNECT POWER FEEDER FROM

INDICATED 460V MOTOR CONTROLLER BACK

TO MOTOR AND POWER SOURCE.

05 DISCONNECT AND REMOVE INDICATED

400-AMP SAFETY SWITCH. REINSTALL THE

SWITCH AT NEW LOCATION. EXTEND

EXISTING WIRING TO RELOCATED

DISCONNECT SWITCH’S NEW LOCATION,

INCLUDING SUPPORTS AND SPLICE BOX IF

REQUIRED.

06 MOTORIZED VALVE ETR. WIRING

CONNECTION TO EXISTING 120V MOTORIZED

VALVE FROM CHILLER CONTROL PANEL.

REWORK WIRING AS REQUIRED TO ACTUATE

EXISTING VALVES FROM NEW CHILLER

CONTROL SYSTEM.

07 REMOVE AND REPLACE INDICATED

12.5KV-4.16KV UNIT SUBSTATION. REFER TO

SEQUENCING PLAN ON E-001 FOR DETAILS.

08 CONTRACTOR SHALL REMOVE INDICATED

EXISTING MOTOR CONTROL CENTER (MCC),

INCLUDING ASSOCIATED FEEDERS AND ALL

BRANCH CIRCUIT WIRING CONNECTED TO

MCC. REFER TO ELECTRICAL SEQUENCING

PLAN ON E-001.

09 INDICATED EXISTING EXHAUST FAN SHALL BE

REPLACED BY MC. REPLACE INDICATED

DISCONNECT SWITCH WITH NEW

COMBINATION MOTOR CONTROLLER. SEE

MECHANICAL EQUIPMENT SCHEDULE FOR

STARTER CHARACTERISTICS. REWORK

EXISTING BRANCH CIRCUIT WIRING AS

REQUIRED AND CONNECT TO DESIGNATED

NEW PANEL.

11 EXISTING FILTER UNIT, '52-CWSSF-11' AND ITS

ASSOCIATED CONTROLLER SHALL BE

REPLACED BY MC. EC SHALL DISCONNECT,

AND REWORK EXISTING ELECTRICAL

SERVICES AS REQUIRED.

12 REFER TO ELECTRICAL SEQUENCING PLAN

FOR REPLACEMENT OF PUMP, NEW MOTOR

WILL BE PROVIDED WITH INTEGRAL VFD.

13 EXISTING REFRIGERANT LOSS MONITOR

PANEL TO BE REPLACED BY MC IS

CONNECTED TO EXISTING RECEPTACLE

OUTLET BELOW WITH CORD AND PLUG.

14 DURING THE REPLACEMENT OF CHILLER #2,

PROVIDE BRANCH CIRCUIT WIRING FOR NEW

52-P-5 AND CONNECT TO PANEL “HM3”.

15 INDICATED TRANSFORMERS TO BE

DEMOLISHED ARE ISOLATION

TRANSFORMERS CONNECTED IN SERIES

WITH ADJACENT VFD CONTROLLERS TO BE

DEMOLISHED.

16 INDICATED DISCONNECTS ARE FED FROM

BELOW.

B. INDICATED CIRCUIT INFORMATION IS BASED ON

RECORD DRAWINGS AND CASUAL FIELD

OBSERVATIONS. CONTRACTOR SHALL VERIFY

INFORMATION PROVIDED AND OBTAIN ANY

INFORMATION NOT PROVIDED THROUGH FIELD

INVESTIGATION.

A. ELECTRICAL EQUIPMENT SHOWN ON THIS SHEET

IS EXISTING TO REMAIN (ETR) UNLESS

OTHERWISE NOTED (UON).

## KEY NOTES:

3 3 3

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

SEE MEZZANNE LIGHTING

DEMOLITION PLAN 1/ED104

FOR THIS AREA

CHILLER PLANT

ENGINEERING OFFICE

STORAGE

WATER SAMPLING

TOILET

107TRANSFORMER VAULT

TRANSFORMER VAULT

CHILLER PLANT

CORRIDOR

CHILLER PLANT

EM

EM

EM

EM

EM

EM

EM

EM

EM

ETR

ETR

ETR

ETR

ETRETR

ETR ETR

ETRETR

ETR

ETR

ETR

Engineers Architects

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:4

P

M

ED102

FIRST FLOOR LIGHTING DEMOLITION PLAN

4 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

FIRST FLOOR LIGHTING DEMOLITION PLAN

01 REMOVE AND REPLACE INDICATED EXISTING

LIGHT SWITCHES AND COVERPLATES WITH

NEW ONES TO MATCH EXISTING.

B. REPLACEMENT OF EXISTING LIGHTING FIXTURES

SHALL BE AN ALTERNATE.

A. REMOVE AND REPLACE EXISTING FLUORESCENT

LIGHT FIXTURES SHOWN WITH DASHED LINES ON

THIS DRAWING. REMOVE AND REPLACE

INDICATED EXIT SIGNS. RETAIN EXISTING

CIRCUITING FOR REUSE. SEE SHEET EL101 FOR

NEW LIGHTING PLAN.

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

(EX) 'MCC-1' - 4R

'MCC-2' - 2A

DOWN TO

DISCONNECT

SWITCH ON

FIRST FLOOR

LEVEL SEE

SHEET ED101

'MCC-1' - 5E 'MCC-2' - 3A

'MCC-1' - 5I

EX 52P-13

EX 52-EF-6

EX 52-EF-5

EX 52-EF-3

EX 52-SF-1

52-AHU-1

52-AHU-2

05 05

'MCC-1' - 6D

EX 52-LA-3

EX 52-LA-4

EX 52-LA-7

EX 52-LA-8

EX 52-LA-10 EX 52-LA-11

TELECOMMUNICATION

ROOM

OFFICE

OFFICE

TOILET

OFFICE

OFFICE

MEZZANINE

MEZZANINE

CORRIDOR

Engineers Architects

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:5

P

M

ED103

MEZZANINE ELECTRICAL DEMOLITION PLAN

5 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

01 DISCONNECT POWER FEEDER FROM

INDICATED 460V MOTOR TO BE REPLACED BY

MC. REMOVE INDICATED FEEDER

CONDUCTORS AND RACEWAYS BACK TO

SOURCE.

02 INDICATED EXISTING EXHAUST FAN SHALL BE

REPLACED BY MC. REPLACE INDICATED

DISCONNECT SWITCH WITH NEW

COMBINATION MOTOR CONTROLLER. SEE

MECHANICAL EQUIPMENT SCHEDULE FOR

STARTER CHARACTERISTICS. REWORK

EXISTING BRANCH CIRCUIT WIRING AS

REQUIRED AND CONNECT TO DESIGNATED

NEW PANEL.

05 MOTORIZED VALVE ETR. WIRING

CONNECTION TO EXISTING 120V MOTORIZED

VALVE FROM CHILLER CONTROL PANEL.

REWORK WIRING AS REQUIRED TO ACTUATE

EXISTING VALVES FROM NEW CHILLER

CONTROL SYSTEM.

06 INDICATED AHU SHALL REMAIN. REPLACE

EXISTING DISCONNECT SWITCH WITH NEW

MOTOR CONTROLLER. SEE SHEET E-701 FOR

CONTROLLER TYPE. COORDINATE WITH MC.

REWORK EXISTING BRANCH CIRCUIT WIRING

AND CONNECT TO DESIGNATED NEW PANEL.

07 DISCONNECT AND REMOVE EXISTING

DISCONNECT SWITCH, INCLUDING

ASSOCIATED BRANCH CIRCUIT WIRING BACK

TO SOURCE.

Scale: 1/4" = 1'-0"

MEZZANINE ELECTRICAL DEMOLITION PLAN

NORTH

0 2 4 8

B. INDICATED CIRCUIT INFORMATION IS BASED ON

RECORD DRAWINGS AND CASUAL FIELD

OBSERVATIONS. CONTRACTOR SHALL VERIFY

INFORMATION PROVIDED AND OBTAIN ANY

INFORMATION NOT PROVIDED THROUGH FIELD

INVESTIGATION.

A. ELECTRICAL EQUIPMENT SHOWN ON THIS SHEET

IS EXISTING TO REMAIN (ETR) UNLESS

OTHERWISE NOTED (UON).

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

01 01

01 01 01

OPEN TO FLOOR BELOW

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

'HCT' - 6

'HCT' - 8

Engineers Architects

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:5

P

M

ED104

MEZZANINE LIGHTING DEMOLITION PLAN

6 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

01 REMOVE AND REPLACE INDICATED EXISTING

LIGHT SWITCHES AND COVERPLATES WITH

NEW ONES TO MATCH EXISTING.

B. REPLACEMENT OF EXISTING LIGHTING FIXTURES

SHALL BE AN ALTERNATE.

A. REMOVE AND REPLACE EXISTING FLUORESCENT

LIGHT FIXTURES SHOWN WITH DASHED LINES ON

THIS DRAWING. REMOVE AND REPLACE

INDICATED EXIT SIGNS. RETAIN EXISTING

CIRCUITING FOR REUSE. SEE SHEET EL102 FOR

NEW LIGHTING PLAN.

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

MEZZANINE LIGHTING DEMOLITION PLAN

GFI

WP

GFI

WP

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

H T H

VS

H T H

VS

H T H

VS

H T H

VS

H T H

VS

BASIN WATER HEATER

(TYPICAL)

BASIN WATER THERMOSTAT

(TYPICAL)

LOW WATER LEVEL BASIN HEATER

SHUTDOWN SENSOR

(TYPICAL)

VIBRATION SHUTDOWN SWITCH

WITH MANUAL RESET

(TYPICAL)

VERIFY EXACT

LOCATION IN FIELD

(TYPICAL)

'MCC-2'

COOLING TOWER FAN MOTOR

(TYPICAL)

DISCONNECT SWITCH FOR

CT-3, CELL-5 FAN MOTOR

'MCC-2'

'MCC-2' 'MCC-2'

'MCC-1'

'MCC-1'

'MCC-EQB'

L L L L L

LIGHTNING PROTECTION

AIR TERMINAL

(TYPICAL)

HCT-11

HCT-11

HCT-11

BASIN HEATER

CONTROL PANEL

(TYPICAL)

DISCONNECT SWITCH FOR

CT-3, CELL 5 BASIN HEATERS

CONTROLLER

FOR DOLPHIN 5

CONTROLLER

FOR DOLPHIN 4

CONTROLLER

FOR DOLPHIN 3

CONTROLLER

FOR DOLPHIN 1

CONTROLLER

FOR DOLPHIN 2

T

AMBIENT

TEMPERATURE

SENSOR

'LCT LT'

-39,41

'LCT'-65

WATER LEVEL CONTROLLER

'LCT LT'

-39,41

DISCONNECT

SWITCH FOR

CT-2, CELL-4

FAN MOTOR

DISCONNECT

SWITCH FOR

CT-2, CELL-3

FAN MOTOR

DISCONNECT

SWITCH FOR

CT-2, CELL-4

BASIN HEATERS

DISCONNECT

SWITCH FOR

CT-2, CELL-3

BASIN HEATERS

DISCONNECT

SWITCH FOR

CT-1, CELL-1

BASIN HEATERS

'LCT LT'

-39,41

'LCT LT'

-39,41

DISCONNECT SWITCH FOR

CT-1, CELL-2 BASIN HEATERS

B H

C P

B H

C P

B H

C P

B H

C P

B H

C P

EXISTING PITCH-PAN WITH (4) 1"C & (1) 1-1/2"C

THROUGH ROOF FROM BELOW.

EXISTING PITCH-

PAN WITH (3) 3/4"C

& (2) 2"C THROUGH

ROOF FROM

BELOW.

EXISTING PITCH-PAN

WITH (3) 1"C, (1) 3/4"C &

(2) 2"C THROUGH ROOF

FROM BELOW.

01 01

'LCT'-65

EXISTING UNDERGROUND

GROUND RING ELECTRODE

TO REMAIN, TYPICAL.

DISCONNECT

SWITCH FOR

CT-1, CELL-1

FAN MOTOR

DISCONNECT

SWITCH FOR

CT-1, CELL-2

FAN MOTOR

EX 52CT-1A

EX 52CT-3

EX 52CT-2B

EX 52CT-2A EX 52CT-1B

FLOOR MOUNTED

JUNCTION BOX

(TYPICAL)

ETR

ETR

ETR

ETR

ETR

ETR ETR

EX 52CT-3 EX 52CT-2B EX 52CT-2A EX 52CT-1B EX 52CT-1A

EX 52-EF-4

Engineers Architects

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:5

P

M

ED105

ROOF ELECTRICAL & LIGHTING

DEMOLITION PLAN

7 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

ROOF ELECTRICAL & LIGHTING DEMOLITION PLAN

01 EXISTING PITCH -PAN WITH INDICATED

CONDUITS THROUGH ROOF FROM BELOW.

PRESERVE AND PROTECT PITCH-PAN AND

CONDUITS CONTAINED WITHIN FOR REUSE

TO FEED NEW COOLING TOWER CIRCUITS.

02 DISCONNECT EXISTING FEEDER TO EXISTING

EXHAUST FAN 52-EF-4. MAINTAIN EXISTING

FEEDER TO FEED NEW REPLACEMENT FAN.

PROVIDE NEW UNFUSED DISCONNECT

SWITCH FOR NEW FAN.

03 REMOVE THREE (3) EXISTING LIGHT FIXTURE

SUPPORT STANDARDS AND ASSOCIATED

FIVE (5) EXISTING HID LIGHT FIXTURES.

REUSE EXISTING LIGHTING BRANCH CIRCUIT

TO FEED NEW LIGHTING ATTACHED TO NEW

COOLING TOWERS.

04 EXISTING PITCH PAN ROOF PENETRATION

WITH EXISTING CONDUITS. REFER TO

DETAILS 1/E-501, 2/E-501, AND 3/E-501.

05 DISCONNECT AND REMOVE ALL COOLING

TOWER EQUIPMENT, ACCESSORIES, AND

ASSOCIATED POWER/CONTROL WIRING BACK

TO SOURCE.

B. INDICATED CIRCUIT INFORMATION IS BASED ON

RECORD DRAWINGS AND CASUAL FIELD

OBSERVATIONS. CONTRACTOR SHALL VERIFY

INFORMATION PROVIDED AND OBTAIN ANY

INFORMATION NOT PROVIDED THROUGH FIELD

INVESTIGATION.

A. ELECTRICAL EQUIPMENT SHOWN ON THIS SHEET

IS EXISTING TO REMAIN (ETR) UNLESS

OTHERWISE NOTED (UON).

3 3 3

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

B1

B1

B1

B1

B1 B1

B1 B1

B1

B1

B1

B1 B1

B1

B1 B1 B1 B1

B1B1

B1

A1

B1

B1 B1

B1 B1 B1

B1 B1

B1 B1

B1

B1 A1

B1 B1

B1

B1

B1 B1

B1

A1

A2 A2 A2

A2

A2

ETR

ETR

ETR

ETR

ETRETR

ETR ETR

ETRETR

ETR

ETR

ETR

EM

EM

EM

EM

EM

SEE MEZZANNE LIGHTING

DEMOLITION PLAN 1/ED104

FOR THIS AREA

CHILLER PLANT

CHILLER PLANT

CHILLER PLANT

TRANSFORMER VAULT

TRANSFORMER VAULT

TOILET

ENGINEERING OFFICE

WATER SAMPLING

STORAGE

CORRIDOR

CORRIDOR

C

EM

EM

EM

EM

EM

EM EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

Engineers Architects

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:0

P

M

EL101

FIRST FLOOR LIGHTING PLAN

8 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

FIRST FLOOR LIGHTING PLAN

01 PROVIDE NEW LIGHT SWITCHES AND COVER

PLATES TO MATCH EXISTING IN EXISTING

OUTLET BOXES WHERE INDICATED.

02 PROVIDE TEMPORARY FEEDER TO CONNECT

ASSOCIATED LIGHTING CIRCUIT TO EXISTING

MCC ‘EQB’-3T FOR 12 HOUR ELECTRICAL

SHUTDOWN. FOR MORE INFORMATION SEE

SHEET E-601.

C. PROVIDE TEMPORARY FEEDER TO CONNECT EM

LIGHTING CIRCUIT TO MCC ‘EQB’-2M FOR 12 HOUR

ELECTRICAL SHUTDOWN. FOR MORE

INFORMATION SEE SHEET E-601.

B. REPLACEMENT OF EXISTING LIGHTING FIXTURES

SHALL BE AN ALTERNATE.

A. INDICATED LIGHT FIXTURES AND EXIT SIGNS

SHALL BE NEW. INSTALL THE NEW FIXTURES IN

APPROXIMATELY THE SAME LOCATIONS AS THE

REMOVED FIXTURES. CONNECT NEW FIXTURES

TO THE EXISTING WIRING AT EXISTING LIGHTING

OUTLET BOXES. SUSPEND FIXTURES FROM

STRUCTURE. MAINTAIN EXISTING LIGHTING

CONTROLS. REWORK EXISTING RACEWAYS AND

CONDUCTORS AS REQUIRED.

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

OPEN TO FLOOR BELOW

'HCT' - 6

'HCT' - 8

01 01 01

A1

B1

B1

B1

A1

B1

B1

B1

A1

B1

B1

B1

A1

B1

B1

B1

A1

B1

B1

B1

A1

B1

B1

B1

A1

B1

B1

B1

A1

B1

B1

B1

B1

B2B2B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

B2

A1 A1 A1

B2B2

B2

B2 B2

B2

A1

B2

B2

B2

A1

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM

EM EM

EM EM

EM

Engineers Architects

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

/2

/2

:0

:0

P

M

EL102

MEZZANINE LIGHTING PLAN

9 19EFJ

UPGRADE CHILLER PLANT

MUSKOGEE VAMC

1011 HONOR HEIGHTS DR,

MUSKOGEE, OK 74401

FEBRUARY 22, 2021

100% BID DOCUMENTS

623-16-10118-416

JAV

N

SCOPE OUTLINE

KEY PLAN

SCALE: NO SCALE

NORTH

0 2 4 8

Scale: 1/4" = 1'-0"

MEZZANINE LIGHTING PLAN

01 PROVIDE NEW LIGHT SWITCHES AND COVER

PLATES TO MATCH EXISTING IN EXISTING

OUTLET BOXES WHERE INDICATED.

C. PROVIDE TEMPORARY FEEDER TO CONNECT EM

LIGHTING CIRCUIT TO MCC ‘EQB’-2M FOR 12 HOUR

ELECTRICAL SHUTDOWN. FOR MORE

INFORMATION SEE SHEET E-601.

B. REPLACEMENT OF EXISTING LIGHTING FIXTURES

SHALL BE AN ALTERNATE.

A. INDICATED LIGHT FIXTURES AND EXIT SIGNS

SHALL BE NEW. INSTALL THE NEW FIXTURES IN

APPROXIMATELY THE SAME LOCATIONS AS THE

REMOVED FIXTURES. CONNECT NEW FIXTURES

TO THE EXISTING WIRING AT EXISTING LIGHTING

OUTLET BOXES. SUSPEND FIXTURES FROM

STRUCTURE. MAINTAIN EXISTING LIGHTING

CONTROLS. REWORK EXISTING RACEWAYS AND

CONDUCTORS AS REQUIRED.

S U B

S U B

F R O N T

T

T

S U B

F R O N T

T

4 F R O N T

S U B

V F

D V

F D

V F

D

VFD VFDVFD

VFD

VFD

VF

D

VFD

VFDVFD

V

FD

VFDVFDVFDVFDVFD VFD

H G.5 G F.5 F E.5 E

6.A

6B

7A

8A

(ETR) SUB #1

SUB #2

(ETR) SUB #4

(ETR) ATS-EQB

(ETR) MCC EQB

(ETR) ATS-SA

SUB #3

'HM2' - 25,27,29

'HM3'

- 13,15,17

(ETR)

VFD 52-P-9

(ETR)

VFD 52-P-10

(ETR)

VFD 52-P-11

040404

'HM2'

- 1,3,5

'HM3'

- 8,10,12

'HM1'

- 14,16,18

'HM2'

- 7,9,11

'HM3'

- 2,4,6

'HM1'

- 13,15,17

'HM1'

- 20,22,24

'HM2'

- 13,15,17

'HM4'

- 7,9,11

'HM1'

- 19,21,23

'HM3'

- 1,3,5

06 0606

'LCT2'

- 1 (PART)

'LCT2'

- 1 (PART)

'LCT2'

- 1 (PART)

'LCT2'

- 1 (PART)

'LCT2'

- 1 (PART)

'LCT2'

- 1 (PART)

'LCT2'

- 1 (PART)

(ETR) PUMP CONTROLLER

'ECHCP' -

7,9,11 09

(ETR) PANEL 'HCT'

(ETR) PANEL 'DP1C'

(ETR) TRANSFORMER 'TA'

(ETR) PANEL 'LCT'

(ETR) PANEL 'EQLCP'

(ETR) TRANSFORMER

(ETR) TRANSFORMER

(ETR) PANEL 'ECHCP'

(ETR) ATS-ECB

(NEW)

'LCT2' - 3

(ETR)

'EQLCP' - 28

'HM2'

- 19,21,23

600A, DISCONNECT

SWITCH

SEE SHEET E-603

52-P-352-P-252-P-12

52-CH-3

52-CH-2 52-CH-1

52-P-1 52-P-4 52-P-6

EX 52-P-9

EX 52-P-10

EX 52-P-11

52-P-8

52-P-7

52-P-13

52-P-5

52-EF-7

52-EF-2

52-LA-6

52-LA-5

52-LA-9

52-LA-12A2 52-LA-12B2

52-LA-12A1 52-LA-12B1

52-LA-1

52-LA-2

'HM3'

- 1,3,5

TO EXHAUST FAN

EF-5 LOCATED ON

MEZZANINE FLOOR.

52-FPHX-1

CONTROL

PANEL

'52-CWCDS-1'

PANEL 'HM2'

PANEL 'HM1'

PANEL 'HM3'

PANEL 'HM4'

EX-52-RLM-1

TRANSFORMER 'TCT2'

(ABOVE PANEL'LCT2')

PANEL 'LCT2'

T

52-CTSSF-1

VFD CT-1, C1

VFD CT-1, C2

VFD CT-2, C3VFD CT-2, C4

VFD CT-3, C5

VFD CT-3, C6

'HM2' -

8,10,12

'HM4' -

20,22,24

'HM1' -

1,3,5

'HM1' -

7,9,11

'HM2' -

2,4,6

'HM4' -

14,16,18

52-CTSSF-1

16 16

16 16 16

TRANSFORMER VAULT

TRANSFORMER VAULT

CHILLER PLANT

TOILET

ENGINEERING OFFICE

WATER SAMPLING

STORAG…

This is the start of the file's text. The full file is on GovTribe.