About this file

This document is a comprehensive set of architectural and engineering construction documents for the Lake Hazel Middle School Phase 4 Renovation project, prepared by Studio H Architects for the West Ada School District (WASD) located in Boise, Idaho. The project involves a phased renovation of an existing middle school, specifically focusing on Phase 4, which encompasses approximately 22,039 square feet of modifications including renovation of science classrooms, library, MDF room, general education classrooms, a new teacher work room, and hallway renovations. The documents include detailed architectural plans, mechanical, electrical, plumbing, technology, and fire protection drawings, with a project timeline indicating design completion on 10/31/2025.

The renovation is designed to comply with the 2018 International Building Code, with the project classified as a Group E (Educational) occupancy in Type II-A construction. The total gross square footage of the facility is 126,692 square feet, with Phase 4 specifically targeting improvements to enhance educational spaces. The project includes comprehensive system upgrades involving new HVAC equipment (12 roof-top units), electrical system modifications, technology infrastructure updates, and fire protection system adjustments. Funding and procurement details are not explicitly outlined in the documents, but the comprehensive nature of the drawings suggests a significant capital investment by the West Ada School District to modernize and improve the Lake Hazel Middle School facility.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

N

PROPERTY

BOUNDARY

LAKE HAZEL

MIDDLE

SCHOOL

W LA GRANGE ST

S

SK

YR

ID

GE

A

VE

S

VA

LL

EY

S T

ABBREVIATIONS

@ AT

# POUND, NUMBER

/O OVER

' FOOT, FEET

" INCH, INCHES

+/- PLUS OR MINUS, VIF

ACM ALUMINUM COMPOSITE MATERIAL

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

AL ALUMINUM

ANSI AMERCIAL NATIONAL

STANDARDS INSTITUTE

ARCH ARCHITECT, ARCHITECTURAL

ASS'Y ASSEMBLY

ASTM AMERICAN SOCIETY OF TESTING

& MATERIALS

A/V AUDIO/VISUAL

B.O. BOTTOM OF

BD BOARD

BLDG BUILDING

CG CORNER GUARD

CLR CLEAR

CLG CEILING

CJ CONTROL JOINT

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUOUS

CPT CARPET

CT CERAMIC/PORCELAIN TILE

D PENNY (NAILS, ETC.)

DBL DOUBLE

DEG DEGREE

DEPT DEPARTMENT

DTL DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DW DISHWASHER

DWGS DRAWINGS

EA EACH

EIFS EXTERIOR INSULATION FINISH

SYSTEM

ELEV ELEVATION

ELEC ELECTRICAL

ENLRG ENLARGED

EXH EXHAUST

(E) EXISTING

EXT EXTERIOR

FAC FACULTY

FCS FAMILY CONSUMER SCIENCE

FD FLOOR DRAIN

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FLR FLOOR

FT FOOT OR FEET

FTG FOOTING

GA GUAGE

GALV GALVANIZED

GYP GYPSUM BOARD

HDWD HARDWOOD

HORIZ HORIZONTAL

HVAC HEATING, VENTILATION, AND

AIR CONDITIONING

IBC INTERNATIONAL BUILDING CODE

IDF INTERMEDIATE DISTRIBUTION

FRAME

IN INCH OR INCHES

INCL INCLUDE

INFO INFORMATION

INT INTERIOR

JT JOINT

LAM LAMINATE

LAV LAVATORY

LB, LBS POUND, POUNDS

MAINT MAINTENANCE

MATL MATERIAL

MAX MAXIMUM

MB MARKERBOARD

MDF MAIN DISTRIBUITION FRAME

MECH MECHANICAL

MTL METAL

MEZZ MEZZANINE

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OC ON CENTER

OPP OPPOSITE

OFCI OWNER-FURNISHED,

CONTRACTOR-INSTALLED

OFOI OWNER-FURNISHED,

OWNER-INSTALLED

OTS OPEN TO STRUCTURE

PH PHASE

PLAM PLASTIC LAMINATE

PL PROPERTY LINE

PLUMB PLUMBING

PLYWD PLYWOOD

PREP PREPARE/PREPARATION

PTD PAINTED

PVC POLY-VINYL CHLORIDE

QTY QUANTITY

RB RUBBER OR RESILIENT BASE

RD ROOF DRAIN

RE: REFERENCE

REF REFRIGERATOR

REQ'D REQUIRED

REV REVISION

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RR RESTROOM

SECT SECTION

SHT SHEET

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

SS SOLID SURFACE

SST STAINLESS STEEL

STOR STORAGE

STRUC STRUCTURAL

SUSP SUSPENDED

SYM SYMMETRICAL

T&G TONGUE AND GROOVE

T.O. TOP OF

TYP TYPICAL

UL UNDER WRITER'S LABORATORY

UNO UNLESS NOTED OTHERWISE

VERT VERTICAL

VIF VERIFY IN FIELD

VTR VENT THRU ROOF

W/ WITH

WD WOOD

W/O WITHOUT

YD YARD

A101

SYMBOLS LEGEND

ELEVATION MARKER

DOOR TAG101

WALL TAG

WINDOW TAG

601S

KEYNOTE TAG

SECTION

DETAIL OR

ENLARGED PLAN

CALLOUT

ELEVATION/LEVEL MARKER

A101

A101

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

PRIOR TO SUBMITTING COST PROPOSAL, THE CONTRACTOR / OWNER SHALL VERIFY EXISTING

CONDITIONS ON SITE & REVIEWE MODIFICATIONS AND DIMENSIONS TO ALIGN WITH THE

CONTRACT DOCUMENTS.

CONTRACTOR / OWNER TO NOTIFY ARCHITECT IMMEDIATELY SHOULD THERE BE ANY

DISCREPANCY IN THE DRAWINGS. IF CONTRACTOR / OWNER PROCEEDS WITHOUT CONTACT

THEN THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY DAMAGE OR

DEFECIENCY.

ALL WORK SHALL MEET FEDERAL, STATE AND LOCAL BUILDING CODES AND ANY ORDINANCES

THAT APPLY TO THE PROPERTY.

CONTRACTOR SHALL REMOVE AND CLEAN SITE ON A DAILY BASIS OR AS DIRECTED BY

OWNER.

NO PORTION OF WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL

COMMENCE UNTIL THE SUBMISSION HAS BEEN REVIEWED AND RESPONDED TO.

CONTRACTOR / OWNER SHALL BE RESPONSIBLE FOR ACCURATE LOCATIONS OF PLOT LINES,

BOUNDARIES AS NOTED ON CIVIL DRAWINGS AND / OR SITE PLAN IF APPLICABLE.

PATCH AND REPAIR ALL EXISTING CONDITIONS TO REMAIN TO AS NEW IF DAMAGE OCCURS.

ALL OPEN JOINTS, PENETRATIONS AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL

BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED TO LIMIT AIR AND WATER

INFILITRATION.

PROVIDE WATER-RESISTANT GYPSUM BOARD AT ALL BATH, TOILET, LAUNDRY OR AN AREA

DEEMED "WET".

PROVIDE TILE BACKER BOARD WHERE TILE OR STONE FINISHES ARE BEING APPLIED.

CONTRACTOR TO COORDINATE WITH OWNER FOR ALL "OWNER PROVIDED" ITEMS.

DO NOT SCALE THE DRAWINGS. CONTACT ARCHITECT FOR CLARIFICATION OF DIMENSIONS

AS NEEDED, TYP.

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

A0.00.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

C O

V E

R S

H E

E T

G

E N

E R

A L

IN

FO

R M

A T

IO

N

IFC

CONSULTANTS

STRUCTURAL ENGINEER

KPFF CONSULTING ENGINEERS

412 E. PARKCENTER BLVD, STE 200

BOISE, ID 83706

208-900-3520

MECHANICAL, PLUMBING &

ELECTRICAL ENGINEER

CATOR, RUMA & ASSOCIATES, CO.

420 S. ORCHARD STREET

BOISE, ID 83705

208-343-3663

SHEET INDEX PH 4

Sheet

Number Sheet Name

0 - GENERAL PH 4

A0.00.4 COVER SHEET & GENERAL INFORMATION

A0.01.4 CODE & LIFE SAFETY PH 4

A0.05.4 ACCESSIBILITY GUIDELINES

A0.10.4 INTERIOR PARTITIONS

A0.11.4 SITE PLAN - FOR REFERENCE ONLY

1- ARCHITECTURE DEMOLITION PH 4

AD0.12.4 PHASE 4 DEMO OVERALL FLOOR PLAN

AD0.13.4 PHASE 4 DEMO OVERALL ROOF PLAN

AD1.01.4 PHASE 4 DEMO FLOOR PLAN

AD1.11.4 PHASE 4 DEMO CEILING PLAN

AD1.20.4 PHASE 4 DEMO ROOF PLAN

2 - ARCHITECTURE & INTERIORS PH 4

A1.00.4 OVERALL FLOOR PLAN PH 4

A1.01.4 PHASE 4 NEW FLOOR PLAN

A1.11.4 PHASE 4 NEW RCP

A1.20.4 PHASE 4 NEW ROOF PLAN

A2.01.4 INTERIOR ELEVATIONS

A2.02.4 INTERIOR ELEVATIONS

A2.03.4 INTERIOR ELEVATIONS

A2.04.4 INTERIOR ELEVATIONS

A4.01.4 ENLARGED PLANS, ELEVATIONS AND DETAILS

A4.02.4 ENLARGED PLANS

A5.02.4 ROOF DETAILS

A5.10.4 CEILING & INTERIOR DETAILS

A5.11.4 MILLWORK DETAILS

A7.01.4 DOOR & WINDOW SCHEDULES AND TYPES

ID1.01.4 PHASE 4 FINISH PLAN

4 - STRUC PH 4

S0.00.4 ABBREVIATIONS, SYMBOLS & SHEET INDEX

S0.01.4 GENERAL STRUCTURAL NOTES

S0.02.4 GENERAL STRUCTURAL NOTES

S0.03.4 STATEMENT OF SPECIAL INSPECTIONS

S2.00.4 OVERALL KEY PLAN - PHASE 4

S2.01.4 PHASE 4 FOUNDATION PLAN - AREA D

S2.02.4 PHASE 4 FLOOR PLAN - AREAS D

S2.03.4 PHASE 4 EXISTING ROOF FRAMING PLAN - AREA D

S3.01.4 PHASE 4 WALL ELEVATIONS

S6.01.4 PHASE 4 DETAILS - AREA D

S6.02.4 PHASE 4 DETAILS - AREA D

4.1 - MECH GENERAL PH4

M0.01.4 MECHANICAL LEGENDS & NOTES - PHASE 4

M0.02.4 MECHANICAL SCHEDULES - PHASE 4

4.2 - MECH DEMO PH4

MD1.01.4 HVAC DEMOLITION PLAN - PHASE 4

MD1.02.4 MEZZANINE HVAC DEMOLITION PLAN - PHASE 4

MD1.03.4 ROOF MECHANICAL DEMOLITION PLAN - PHASE 4

MD1.11.4 HVAC PIPING DEMOLITION PLAN - PHASE 4

MD1.12.4 MEZZANINE HVAC PIPING DEMOLITION PLAN - PHASE 4

4.3 - MECH PH4

M1.01.4 HVAC PLAN - PHASE 4

M1.03.4 ROOF MECHANICAL PLAN - PHASE 4

M1.11.4 HVAC PIPING PLAN - PHASE 4

M1.12.4 MEZZANINE HVAC PIPING PLAN - PHASE 4

5.1 - PLUMB GENERAL PH4

P0.01.4 PLUMBING LEGENDS & NOTES - PHASE 4

5.2 - PLUMB DEMO PH4

PD1.01.4 DOMESTIC WATER DEMOLITION PLAN - PHASE 4

PD1.10.4 FOUNDATION WASTE & VENT DEMOLITION PLAN -

PHASE 4

PD1.11.4 WASTE & VENT DEMOLITION PLAN - PHASE 4

5.3 - PLUMB PH4

P1.01.4 DOMESTIC WATER PLAN - PHASE 4

P1.10.4 FOUNDATION WASTE & VENT PLAN - PHASE 4

P1.11.4 WASTE & VENT PLAN - PHASE 4

6.1 - ELEC GENERAL PH4

E0.01.4 ELECTRICAL LEGENDS & NOTES - PHASE 4

E0.02.4 ELECTRICAL SCHEDULES - PHASE 4

E0.11.4 ELECTRICAL ONE-LINE DIAGRAM - PHASE 4

6.2 - ELEC DEMO PH4

ED1.01.4 LIGHTING DEMOLITION PLAN - PHASE 4

ED1.11.4 POWER DEMOLITION PLAN - PHASE 4

ED1.13.4 ROOF ELECTRICAL DEMOLITION PLAN - PHASE 4

ED1.21.4 FIRE ALARM DEMOLITION PLAN - PHASE 4

6.3 - ELEC PH4

E1.01.4 LIGHTING PLAN - PHASE 4

E1.10.4 PATHWAY PLAN - PHASE 4

E1.11.4 POWER PLAN - PHASE 4

E1.13.4 ROOF ELECTRICAL PLAN - PHASE 4

E1.21.4 FIRE ALARM PLAN - PHASE 4

E3.01.4 ELECTRICAL PANEL SCHEDULES - PHASE 4

E4.01.4 ELECTRICAL DETAILS - PHASE 4

6.4 - FIRE PROTECTION PH4

F0.01.4 FIRE PROTECTION LEGENDS & NOTES - PHASE 4

F1.01.4 FIRE PROTECTION PLAN - PHASE 4

7.0 - TECH GENERAL PH4

T0.01.4 TECHNOLOGY LEGENDS & NOTES - PHASE 4

7.2 - TECH DEMO PH4

TD1.11.4 TECHNOLOGY FLOOR DEMOLITION PLAN - PHASE 4

7.3 - TECH PH4

T1.01.4 TECHNOLOGY PATHWAY PLAN - PHASE 4

T1.11.4 TECHNOLOGY FLOOR PLAN - PHASE 4

T1.12.4 TECHNOLOGY ENLARGED PLAN - PHASE 4

T4.01.4 TECHNOLOGY AND SECURITY DETAILS - PHASE 4

T4.02.4 SINGLE DOOR SECURITY DETAILS - PHASE 4

T4.03.4 DOUBLE DOOR SECURITY DETAILS - PHASE 4

OCCUPANCY SCHEDULE PH 4

OCCUPANCY AREA NAME LOAD FACTOR

TOTAL

OCCUPANTS

90 SF STACK AREA 1:100 1

45 SF STACK AREA 1:100 1

45 SF STACK AREA 1:100 1

45 SF STACK AREA 1:100 1

34 SF STACK AREA 1:100 1

258 SF 5

E

E 837 SF CLASSROOM 1:20 42

E 875 SF CLASSROOM 1:20 44

E 874 SF CLASSROOM 1:20 44

E 868 SF CLASSROOM 1:20 44

E 873 SF CLASSROOM 1:20 44

E 862 SF CLASSROOM 1:20 44

E 837 SF CLASSROOM 1:20 42

E 787 SF CLASSROOM 1:20 40

E 824 SF CLASSROOM 1:20 42

E 815 SF CLASSROOM 1:20 41

E 424 SF CLASSROOM 1:20 22

E 854 SF CLASSROOM 1:20 43

E 1484 SF VOCATIONAL CLASSROOM 1:50 30

E 87 SF SENSORY ROOM 1:20 5

E 120 SF STORAGE 1:300 1

E 144 SF STORAGE 1:300 1

E 654 SF FACULTY LOUNGE 1:15 44

E 137 SF CLASSROOM 1:20 7

E 136 SF CLASSROOM 1:20 7

E 136 SF OFFICE 1:150 1

E 78 SF MAINT 1:300 1

E 75 SF ELEC 1:300 1

E 426 SF STORAGE 1:300 2

E 819 SF CLASSROOM 1:20 41

E 826 SF CLASSROOM 1:20 42

E 791 SF CLASSROOM 1:20 40

E 1066 SF SCIENCE CLASSROOM 1:50 22

E 1094 SF SCIENCE CLASSROOM 1:50 22

E 1097 SF SCIENCE CLASSROOM 1:50 22

E 814 SF STORAGE 1:300 3

E 1101 SF SCIENCE CLASSROOM 1:50 23

E 1107 SF SCIENCE CLASSROOM 1:50 23

E 1079 SF SCIENCE CLASSROOM 1:50 22

E 803 SF CLASSROOM 1:20 41

E 831 SF CLASSROOM 1:20 42

E 834 SF CLASSROOM 1:20 42

E 820 SF CLASSROOM 1:20 41

E 815 SF CLASSROOM 1:20 41

E 782 SF CLASSROOM 1:20 40

E 827 SF CLASSROOM 1:20 42

E 840 SF CLASSROOM 1:20 42

E 846 SF CLASSROOM 1:20 43

E 840 SF CLASSROOM 1:20 42

E 846 SF CLASSROOM 1:20 43

E 846 SF CLASSROOM 1:20 43

E 845 SF CLASSROOM 1:20 43

E 1435 SF THEATER CLASSROOM 1:50 29

E 773 SF CLASSROOM 1:20 39

E 44 SF STORAGE 1:300 1

E 90 SF STORAGE 1:300 1

E 1585 SF ART CLASSROOM 1:50 32

E 135 SF STORAGE 1:300 1

E 123 SF STORAGE 1:300 1

E 73 SF ELEC 1:300 1

E 86 SF IT 1:300 1

E 125 SF SENSORY ROOM 1:20 7

E 121 SF SENSORY ROOM 1:20 7

E 122 SF SENSORY ROOM 1:20 7

E Not

Enclosed

READING ROOM 1:50 74

E 133 SF STORAGE 1:300 1

E 102 SF IT 1:300 1

E 858 SF CLASSROOM 1:20 43

E 784 SF CLASSROOM 1:20 40

E 878 SF CLASSROOM 1:20 44

E 201 SF ELEC 1:300 1

E 380 SF WORK ROOM 1:150 3

E 200 SF MAINT 1:300 1

E 718 SF OFFICE 1:150 5

E 383 SF CLASSROOM 1:20 20

E 5090 SF CAFETERIA 1:15 340

E 1502 SF KITCHEN 1:200 8

E 126 SF STORAGE 1:300 1

E 88 SF FREEZER 1:300 1

E 89 SF COOLER 1:300 1

E 560 SF MAINT 1:300 2

E 627 SF MECH 1:300 3

E 185 SF IT 1:300 1

E 5607 SF ADMIN OFFICES 1:150 38

E 1895 SF MUSIC CLASSROOM 1:50 38

E 150 SF STORAGE 1:300 1

E 73 SF STORAGE 1:300 1

E 128 SF OFFICE 1:150 1

E 129 SF OFFICE 1:150 1

E 2574 SF MUSIC CLASSROOM 1:50 52

E 973 SF CLASSROOM 1:20 49

E 1041 SF WEIGHT ROOM 1:50 21

E 4000 SF GYMNASIUM 1:50 80

E 137 SF STORAGE 1:300 1

E 511 SF STORAGE 1:300 2

E 4196 SF GYMNASIUM 1:50 84

E 85 SF STORAGE 1:300 1

E 86 SF STORAGE 1:300 1

E 112 SF ELEC 1:300 1

E 93 SF OFFICE 1:150 1

E 760 SF BOYS LOCKERS 1:50 16

E 77 SF STORAGE 1:300 1

E 644 SF GIRLS LOCKERS 1:50 14

E 117 SF OFFICE 1:150 1

E 140 SF STORAGE 1:300 1

E 1640 SF WRESTLING ROOM 1:50 33

E 166 SF STORAGE 1:300 1

E 278 SF MAINT 1:300 1

E 291 SF FIRE RISER 1:300 1

E 141 SF STORAGE 1:300 1

E 1341 SF VOCATIONAL CLASSROOM 1:50 28

E 905 SF CLASSROOM 1:20 46

E 873 SF CLASSROOM 1:20 44

E 860 SF CLASSROOM 1:20 43

E 919 SF CLASSROOM 1:20 46

E 234 SF MAINT 1:300 1

E 103 SF PRACTICE 1:50 3

E 145 SF STORAGE 1:300 1

E 87 SF STORAGE 1:300 1

E 125 SF PRACTICE 1:50 3

E 49 SF PRACTICE 1:50 1

E 49 SF PRACTICE 1:50 1

E 54 SF PRACTICE 1:50 2

E 54 SF PRACTICE 1:50 2

E 125 SF PRACTICE 1:50 3

E 60 SF PRACTICE 1:50 2

E 60 SF PRACTICE 1:50 2

E 60 SF PRACTICE 1:50 2

E 83537 SF 2788

Grand total 83795 SF 2793

No. Description Date

1 LIBRARY CIRCULATION - 3D VIEW FOR REFERENCE ONLY

09/25/2025

F.E.C.

F.E.C.

F.

E.

C

F.

E.

C

F.E.C.

F.

E.

C

F.E.C.

F.E.C.

F.E.C.F.E.C.

F.E.C.

F.E.C.

F.E.C.

F.

E.

C

F.E.C. F.E.C.

F.E.C.

F.

E.

C

F.E.C.

F.

E.

C

F.E.C.

F.

E.

C

F.

E.

C

F.

E.

C

F.

E.

C

F.

E.

C

ROOM NAME AND NUMBER

(NON-OCCUPANCY LOADED SPACE)

OCCUPANT LOAD IN ROOM (I.B.C. TABLE 1004.1.1)

SPACE OCCUPANT LOAD AND DIRECTION OF

EGRESS

REQUIRED EXIT WIDTH (AS PER I.B.C. TABLE 1005.1)

ACTUAL EXIT WIDTH

1-HOUR WALL (45 MIN. OPENING)

2-HOUR WALL (90 MIN. OPENING)

LOCATION OF FIRE EXTINGUISHER CABINET.

MAXIMUM TRAVEL DISTANCE

Room name

ACCUMULATED OCCUPANT LOAD AND DIRECTION

OF EGRESS

BUILDING OCCUPANT LOAD AND DIRECTION OF

EGRESS

CODE AND LIFE SAFETY PLAN LEGEND

BUSINESS

CONTRIBUTING AREA

OCCUPANT LOAD

AREA:

OCC. #:

1 3

A A

C C

D D

E E

F F

G G

H H

J J

21.5

1.5

31 1

43 43 43 42 43 42 42

414242

232424 1 1 1

32 33

2 2 2

44 33

23941

117 9

184409

129449

4675267

42 44 44 44 44 44 42

42 4041

222222 41 42 40

53 1

76135

81 22814212 13

131 172

103 16781126

1 1

136" EGRESS

906 MAX OCCUPANTS

60' SEATING AREA = 225 OCCUPANTS

±38 OCCUPANTS PER ROW - 6 TOTAL ROWS = 225 TOTAL OCCUPANTS

(2) 68" EGRESS

453 MAX OCCUPANTS EACH

TOTAL 960 OCCUPANTS

91' - 1"

EXISTING 2 HOUR RATED AREA

SEPARATION WALL WITH 1 1/2 HOUR

RATED DOORS/FRAMES

296206

198 310

AREA:

OCC. #:

L.F.:

837 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

875 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

874 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

868 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

873 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

862 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

837 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

787 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

824 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

815 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

424 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

854 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

1484 SF

VOCATIONAL

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

87 SF

SENSORY

ROOM

1:20

AREA:

OCC. #:

L.F.:

120 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

144 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

654 SF

FACULTY

LOUNGE

1:15

AREA:

OCC. #:

L.F.:

137 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

136 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

136 SF

OFFICE

1:150

AREA:

OCC. #:

L.F.:

78 SF

MAINT

1:300

AREA:

OCC. #:

L.F.:

75 SF

ELEC

1:300

AREA:

OCC. #:

L.F.:

426 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

819 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

826 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

791 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

1066 SF

SCIENCE

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

1094 SF

SCIENCE

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

1097 SF

SCIENCE

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

814 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

1101 SF

SCIENCE

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

1107 SF

SCIENCE

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

1079 SF

SCIENCE

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

803 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

831 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

834 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

820 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

815 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

782 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

827 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

840 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

846 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

840 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

846 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

846 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

845 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

1435 SF

THEATER

CLASSROOM

1:50 AREA:

OCC. #:

L.F.:

773 SF

CLASSROOM

1:20AREA:

OCC. #:

L.F.:

44 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

90 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

1585 SF

ART

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

135 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

123 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

73 SF

ELEC

1:300

AREA:

OCC. #:

L.F.:

86 SF

IT

1:300

AREA:

OCC. #:

L.F.:

125 SF

SENSORY

ROOM

1:20

AREA:

OCC. #:

L.F.:

121 SF

SENSORY

ROOM

1:20

AREA:

OCC. #:

L.F.:

122 SF

SENSORY

ROOM

1:20

AREA:

OCC. #:

L.F.:

Not Enclosed

READING

ROOM

1:50

AREA:

OCC. #:

L.F.:

133 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

102 SF

IT

1:300

AREA:

OCC. #:

L.F.:

858 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

784 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

878 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

201 SF

ELEC

1:300

AREA:

OCC. #:

L.F.:

380 SF

WORK

ROOM

1:150

AREA:

OCC. #:

L.F.:

200 SF

MAINT

1:300

AREA:

OCC. #:

L.F.:

718 SF

OFFICE

1:150

AREA:

OCC. #:

L.F.:

383 SF

CLASSROOM

1:20

7 7 1

100 166

AREA:

OCC. #:

L.F.:

5090 SF

CAFETERIA

1:15

AREA:

OCC. #:

L.F.:

1502 SF

KITCHEN

1:200

AREA:

OCC. #:

L.F.:

126 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

88 SF

FREEZER

1:300

AREA:

OCC. #:

L.F.:

89 SF

COOLER

1:300

AREA:

OCC. #:

L.F.:

560 SF

MAINT

1:300

AREA:

OCC. #:

L.F.:

627 SF

MECH

1:300

AREA:

OCC. #:

L.F.:

185 SF

IT

1:300

AREA:

OCC. #:

L.F.:

5607 SF

ADMIN

OFFICES

1:150

AREA:

OCC. #:

L.F.:

1895 SF

MUSIC

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

150 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

73 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

128 SF

OFFICE

1:150

AREA:

OCC. #:

L.F.:

129 SF

OFFICE

1:150

AREA:

OCC. #:

L.F.:

2574 SF

MUSIC

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

973 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

1041 SF

WEIGHT

ROOM

1:50

AREA:

OCC. #:

L.F.:

4000 SF

GYMNASIUM

1:50

AREA:

OCC. #:

L.F.:

137 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

511 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

4196 SF

GYMNASIUM

1:50

AREA:

OCC. #:

L.F.:

85 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

86 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

112 SF

ELEC

1:300

AREA:

OCC. #:

L.F.:

93 SF

OFFICE

1:150

AREA:

OCC. #:

L.F.:

760 SF

BOYS

LOCKERS

1:50

AREA:

OCC. #:

L.F.:

77 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

644 SF

GIRLS

LOCKERS

1:50

AREA:

OCC. #:

L.F.:

117 SF

OFFICE

1:150

AREA:

OCC. #:

L.F.:

140 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

1640 SF

WRESTLING

ROOM

1:50

AREA:

OCC. #:

L.F.:

166 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

278 SF

MAINT

1:300

AREA:

OCC. #:

L.F.:

291 SF

FIRE RISER

1:300

AREA:

OCC. #:

L.F.:

141 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

1341 SF

VOCATIONAL

CLASSROOM

1:50

AREA:

OCC. #:

L.F.:

905 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

873 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

860 SF

CLASSROOM

1:20 AREA:

OCC. #:

L.F.:

919 SF

CLASSROOM

1:20

AREA:

OCC. #:

L.F.:

234 SF

MAINT

1:300

AREA:

OCC. #:

L.F.:

103 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

145 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

87 SF

STORAGE

1:300

AREA:

OCC. #:

L.F.:

125 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

49 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

49 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

54 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

54 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

125 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

60 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

60 SF

PRACTICE

1:50

AREA:

OCC. #:

L.F.:

60 SF

PRACTICE

1:50

426 156

AREA:

OCC. #:

L.F.:

90 SF

STACK

AREA

1:100

AREA:

OCC. #:

L.F.:

45 SF

STACK

AREA

1:100

AREA:

OCC. #:

L.F.:

45 SF

STACK

AREA

1:100

AREA:

OCC. #:

L.F.:

45 SF

STACK

AREA

1:100

AREA:

OCC. #:

L.F.:

34 SF

STACK

AREA

1:100

PROJECT DESCRIPTION

Renovation of Lake Hazel Middle School with a phased approach. The scope of Phase 4 consists of the renovation of existing science classrooms, library, MDF, general education classrooms, new teacher work room and hallway renovations.

Note: Tenant space shall follow the Prescriptive Compliance Method of the 2018 International Existing Building Code for Alterations where the new construction shall comply with the 2018 International Building Code and 2009 ANSI A117.1.

Total Gross Square Footage: 126,692 SF Phase 4 Square Footage: 22,039 SF

CODE ANALYSIS

1. DISTRICT - ADOPTED CODES (AND APPLICABLE STANDARDS)

2018 International Building Code 2018 International Existing Building Code 2018 International Fire Code 2018 International Mechanical Code 2017 Idaho State Plumbing Code 2017 National Electrical Code 2018 International Energy Conservation Code 2009 ICC/ANSI A117.1 Accessibility requirements standards

2. OCCUPANCY CLASSIFICATION - Section 302, 303.1.3, & 305

Occupancy Groups and Square Footage: Assembly areas accessory to Group E occupancies are not considered separate occupancies.

Group E - Education

3. TYPE OF CONSTRUCTION - Section 602, 602.2 and 603

Type II-A a.

a.

a.

12. REQUIRED FIRE RESISTANCE OF EXTERIOR WALLS DUE TO

FIRE SEPARATION DISTANCE

Table 602 - Fire resistance requirements for Exterior Walls Based on Fire Separation Distance, Type II-A Construction, Occupancy Group E Fire Separation Distance X < 5'-0" 1 Hour

5'-0"≤ X < 10'-0" 1 Hour 10'-0"≤ X < 30'-0" 0 Hours X ≥ 30'-0" 0 Hours

13. PROTECTION OF OPENINGS BASED ON FIRE SEPARATION

DISTANCE AND DEGREE OF OPENING PROTECTION

Table 705.8 3 to less than 5 feet unprotected, sprinklered 15% protected 15% 5 to less than 10 feet unprotected, sprinklered 25% protected 25% 10 to less than 15 feet unprotected, sprinklered 45% protected 45%

15. NON SEPARATED OCCUPANCIES

Section 508.3 -Nonseparated occupancies.

Group Occupancy -E / B

17. SPECIAL INSPECTIONS REQUIRED - CHAPTER 17

YES, See Structural Drawings

18. IECC COMPLIANCE REPORT - IBC 1301 & 2012 IECC

See Mechanical Drawings

MALE

19 (18.5)

TOTAL REQUIRED = 38

LAVATORY LAVATORY

FEMALE MALE

FEMALE

TOTAL PROVIDED = 53

DRINKING FOUNTAIN DRINKING FOUNTAIN

TOTAL REQUIRED = 10 (9.89) TOTAL PROVIDED = 18

SERVICE SINK SERVICE SINK

TOTAL REQUIRED = 2 TOTAL PROVIDED = 3

a.

b.

a.

b.

a.

b.

4. FIRE SPRINKLER - Section 903

Structure is Sprinklered

5. FIRE ALARM

Yes

6. ALLOWABLE HEIGHT - Table 504.3

Basic Allowable Height = 65' Feet

Actual Building Height = 23' - 6"; OK

7. ALLOWABLE STORIES - Table 504.4

Basic allowable stories = 3 Stories

Actual Building stories = 1 Story; OK

8. ALLOWABLE AREAS - Table 506.2

Basic Allowable Area per Story = 106,000 SF Actual Area per Story = 126,692 SF

Building split into two fire areas with 2 hour fire wall.

a.

b.

c.

d.

e.

f.

a.

1.

2.

3.

4.

5.

6.

7.

9. OCCUPANT LOAD PER FLOOR - Section 1004

Total Occupant Load = 2,799

10. EXIT ACCESS - Section 1006.2.1, 1016, 1017 and Table 1017.2

See Life Safety Plans on this sheet

Common Path of Egress Travel Occupancy E, sprinklered = 75 feet

Spaces with one exit or exit access doorway Occupancy E - Maximum Occupant Load = 49

Three or more exits or exit access doorways Three exits required for occupant load of 501 to 1,000

Boiler Rooms Two exit access doorways are required where area is over 500 sf

Exit Access Travel Distance Occupancy E, sprinklered = 250 feet

11. FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING

ELEMENTS

Table 601 -Type II-B Construction Building Element Fire rating Structural Frame 0 hr Exterior Bearing Walls 0 hr Interior Bearing Walls 0 hr Exterior non bearing Walls See table 602 Interior Non bearing Walls 0 hr Floor Construction 0 hr Roof Construction 0 hr

Table 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES Total Building Occupancy = 2,799 (See breakdown on Sheet A0.00)*

E OCCUPANCY - 1,400 MAX STUDENTS - 1,400 / 2 = 700 OCC PER GENDER

MALE - 700 OCC. FEMALE - 700 OCC.

WC

LAV

DF

SS

(1:50) 700 / 50 = 14

(1:150) 1,400 / 150 = 9.33

TOTAL MINIMUM REQUIRED

MALE

TOTAL REQUIRED = 42

ACTUAL PROVIDED

WATER CLOSET WATER CLOSET

FEMALE

27 (26.33)

MALE

FEMALE

TOTAL PROVIDED = 57

URINAL

MALE

TOTAL PROVIDED = 10

B OCCUPANCY - 84 STAFF MEMBERS - 84/ 2 = 42 OCC PER GENDER

MALE - 42 OCC. FEMALE - 42 OCC.

WC

LAV

DF

SS

(1: 1-50) = 1 (3: 31-50) = 3

(1: 1-50) = 1

(1:150) 84 / 150 = 0.56

(1:40) 700 / 40 = 17.5

TOTAL MINIMUM REQUIRED ACTUAL PROVIDED

(1:30) 700 / 30 = 23.33

*NOTE: THE TOTAL SEATING CAPACITY IN THE MAIN GYM IS 799. THEREFORE THE STUDENT CAPACITY SHALL GOVERN FOR ABOVE TABLE.

RESTROOM FACILITIES ARE PROVIDED IN HALLWAYS, LOCKER ROOMS, COACH'S OFFICES, KITCHEN, ADMIN OFFICES AND SPECIAL EDUCATION.

(1:40) 700 / 40 = 17.5 19 (18.5)

(1: 1-50) = 1

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

A0.01.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

C O

D E

L

IF

E

S A

FE

T

Y P

H

IFC

N

1/16" = 1'-0"1 1ST FLOOR LIFE SAFETY & EGRESS PLAN PH 4

No. Description Date

09/25/2025

JulieMiller Cloud+

JulieMiller Cloud+ 1:100 = 14

JulieMiller Cloud+

JulieMiller Cloud+ 1:100 = .84

JulieMiller Callout

TOTAL = 14 + .84 = 14.84 = 15

JulieMiller Text Box

JulieMiller Text Box

JulieMiller Text Box

JulieMiller Text Box

JulieMiller Text Box

JulieMiller Text Box

JulieMiller Callout

REPLACE W/HI/LO AND BOTTLE FILLER

JulieMiller Callout

REPLACE W/HI/LO AND BOTTLE FILLER

1.1 DOOR HARDWARE: HANDLES, KNOBS, PULLS, LATCHES, LOCKS, AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL BE MOUNTED AT 34" MIN. AND 48" MAX. ABOVE THE FLOOR OR GROUND SURFACE AND SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE.

1.2 SLIDING DOORS: WHEN SLIDING DOORS ARE FULLY OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH

SIDES.

1.3 DOOR CLOSERS: CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE

THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MINIMUM.

1.4 DOOR OPENING FORCE: FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE FORCE FOR PUSHING AND PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:

1. INTERIOR HINGED DOOR: 5.0 POUNDS MAXIMUM

2. SLIDING OR FOLDING DOOR: 5.0 POUNDS MAXIMUM

3. EXTERIOR HINGED DOORS: (RESERVED)

THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE

DOOR IN A CLOSED POSITION.

FOR HINGED DOORS, THE FORCE SHALL BE APPLIED PERPENDICULAR TO THE DOOR AT THE DOOR OPENER OF 30" FROM THE HINGED SIDE, WHICHEVER IS FARTHER FROM THE HINGE. FOR SLIDING OR FOLDING DOOORS, THE FORCE SHALL BE APPLIED PARALLEL TO THE

DOOR AT THE DOOR PULL OR LATCH.

1.5 DOOR SURFACE: DOOR SURFACES WIHTIN 10" OF THE FLOOR , MEASURED VERTICALLY, SHALL BE A SMOOTH SURFACE ON THE

PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR.

1I - HINGED DOOR 1J - OPENING WITHOUT DOOR

14G - FRONT APPROACH, PULLSIDE, RECESSED DOOR 14H - FRONT

APPROACH, PUSHSIDE

RECESSED DOOR

1E - LATCH APPROACH, PULLSIDE 1F - LATCH

APPROACH, PUSHSIDE

1D - HINGE

APPROACH, PUSHSIDE

1C - HINGE APPROACH, PULLSIDE

1A - FRONT APPROACH, PULLSIDE 1B - FRONT

APPROACH, PUSHSIDE

1 - MANEUVERING CLEARANCE AT DOORS1 - MANEUVERING CLEARANCE AT DOORS

INDICATES DIRECTION OF APPROACH MANEUVERING SPACES SHALL BE LEVEL WITH A

MAXIMUM SLOPE OF 1:48 (2%) IN ANY DIRECTION.

" M

IN

18" MIN.

" M

IN

BOTH A CLOSER AND A LATCH

X = 12" IF THE DOOR HAS

X

X=42" MIN. IF Y=54" MIN.

X=36" MIN. IF Y=60" MIN.

Y=

" M

IN

Y=

" M

IN

22" MIN.

BOTH A CLOSER AND A LATCH

X = 12" IF THE DOOR HAS

Y

Y=42" MIN. TYP.

Y=48" MIN. IF DOOR HAS BOTH A CLOSER AND A LATCH

24" MIN.Y

Y = 48" MIN. TYP.

Y = 54" MIN. IF CLOSER IS PROVIDED

24" MIN.

Y

Y = 42" MIN. TYP.

Y = 48" MIN. IF CLOSER IS PROVIDED

BOTH A CLOSER AND A LATCH

X = 12" IF THE DOOR HAS

" M

IN

8"

18" MIN.

8"60

" M

IN

.00

32" MIN. 36" MIN.

2 - PROTRUDING OBJECTS2 - PROTRUDING OBJECTS

2.1 OBJECTS WITH

LEADING EDGES MORE

THAN 27" AND NOT

MORE THAN 80" ABOVE

THE FLOOR SHALL

PROTRUDE 4" MAX.

HORIZONTALLY INTO

THE CIRCULATION

PATH.

2.2 PROTRUDING

OBJECTS SHALL NOT

REDUCE THE MIN.

CLEAR WIDTH

REQUIRED AT

ACCESSIBLE ROUTES.

2.3 HANDRAILS SHALL

BE PERMITTED TO

PROTRUDE 4-1/2" MAX.

4" MAX.

X

X

X

ANY

AMOUNT

3 - SIGNAGE 3 - SIGNAGE

MOUNTING &MOUNTING &

REQUIREMENTSREQUIREMENTS

3.1 SIGNAGE EXHIBITS ADDRESS MOUNTING

HEIGHTS ONLY. REFER TO SIGNAGE

CONSULTANT'S SUBMITTALS FOR VISUAL

CHARACTER, RAISED CHARACTER AND

BRAILLE REQUIREMENTS.

3.2 ALTERNATE MOUNTING HEIGHTS

ALLOWABLE FOR RAISED CHARACTER

SIGNAGE AT ELEVATOR CARS.

AREA OF

REFUGE

BRAILLE

RAISED

CHARACTERS

" M

IN

" M

AX

OF

B

RA

ILL

E

"-6 0"

T O

BA

SE

LIN

E

4.1 ALL ROOMS SERVED BY AN ACCESSIBLE ROUTE SHALL

PROVIDE EITHER A CIRCULAR OR T-SHAED TURNING SPACE

AS ILLUSTRATED.

EXCEPTION: MECHANICAL CLOSETS, STORAGE

CLOSETS, ELECTRICAL CLOSETS ARE NOT

REQUIRED TO PROVIDE A TURNING SPACE.

4.2 FLOOR SURFACES AT ALL TURNING SPACES SHALL BE

1:48 (2%) MAX. SLOPE.

4.3 T-SHAPED TURNING SPACE ALOWED TO INCLUDE KNEE

& TOE CLEARANCE ONLY AT THE END OF EITHER THE BASE

OR ONE ARM.

4 - TURNING SPACE4 - TURNING SPACE

5'-0"�

�1'-0" �3'-0" �1'-0"

2'

-0

3'

-0

5'

-0

RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE

STEEPER THAN 1:20 (2%) CROSS SLOPE OF WALKING

SURFACES SHALL NOT BE STEEPER THAN 1:48 (2%)

5 - ACCESSIBLE ROUTE5 - ACCESSIBLE ROUTE

5A - CLEAR WIDTH AT 180 DEG. TURN

" M

IN

42" MIN.

< 48"

42" MIN.

" M

IN

36" MIN.

< 48"

36" MIN.

" M

IN

24" MAX. 48" MIN. 24" MAX.

" M

IN

5B - CLEAR WIDTH OF AN

ACCESSIBLE ROUTE

6 - ACCEPTABLE THRESHOLDS6 - ACCEPTABLE THRESHOLDS

CHANGE IN LEVEL MAXIMUMSCHANGE IN LEVEL MAXIMUMS

NOTE: THE HEIGHT OF ANY FLOOR LEVEL CHANGE PLUS THE

HEIGHT OF ANY APPLIED THRESHOLD AT DOORWAY SILLS SHALL

NOT EXCEED 1/2" AND SHALL BE BEVELED WITH A SLOPE NO

GREATER THAN 1:2. SEE FIGURES 6.1 THRU 6.6

MA

X.

1/

4" 1:2 MAX.

MA

X.

1/2

MA

X.

1/4

1:2 MAX.

MA

X.

1/

4"

MA

X.

1/ 2"

MA

X.

1/4

MA

X.

1/2

�1:2 BEVEL, TYP.

AT EACH SIDE

FIG. 6.1

FIG. 6.2

FIG. 6.3

FIG. 6.4

FIG. 6.5

FIG. 6.6

FIG. 6.7 FIG. 6.8 FIG. 6.9

1:2 BEVEL

MA

X.

1/

4"

MA

X.

1/

2"

MA

X.

1/

2"

1:2 BEVEL MA

X.

1/4

� MA

X.

1/

2"

1:2 BEVEL

MA

X.

1/

2"

7 - REACH RANGES FOR OPERABLE CONTROLS, 7 - REACH RANGES FOR OPERABLE CONTROLS,

SWITCHES, OUTLETS, ETC.SWITCHES, OUTLETS, ETC.

7C - UNOBSTRUCTED FORWARD REACH

>10" -24" 30"

" M

AX

" M

AX

" M

IN

.48 " M

AX

�48"

Z = X OR GREATER

20" MAX.

X= > 20" - 25"

Y

" M

AX

Y

" M

AX

7B - OBSTRUCTED HIGH FORWARD

REACH

7E - OBSTRUCTED HIGH SIDE REACH

" M

AX

" M

IN

ITEMS WITHIN

DASHED LINES ARE

WITHIN REACH

X = REACH DISTANCE.

Y = MAXIMUM HEIGHT

Z = CLEAR KNEE SPACE

Z IS THE CLEAR SPACE BELOW THE OBSTRUCTION WHICH

SHALL BE AT LEAST AS DEEP AS THE REACH DISTANCE X.

10" MAX.

�30"

" M

AX

" M

AX

7D - OBSTRUCTED HIGH SIDE REACH

10" MAX.

�30"

" M

AX

" M

AX

MAX.

10" �30"

7F - UNOBSTRUCTED SIDE REACH

7A - CONTROL LOCATIONS WITH

NO OBSTRUCTIONS

6.1 48" MAX. & 15" MIN. APPLY IN NO OBSTRUCTION

CONDITIONS - SEE FIGS 7B, 7D & 7E FOR REACH

RANGES OVER OBSTRUCTIONS.

6.2 PROTECTIVE COVERS AT CONTROLS SHALL NOT

PROJECT MORE THAN 4" FROM FACE OF WALL.

T

ELECT. OUTLETSELECT. SWITCHES

& CONTROLS

ELECT. OUTLETS TV, PHONE & DATA

CONNECTIONS

" M

IN

" M

AX

8 - RESTROOM CLEAR FLOOR SPACE8 - RESTROOM CLEAR FLOOR SPACE

NOTE: DOOR SHALL NOT SWING INTO REQ. CLEAR

FLOOR SPACE AT ACCESSIBLE COMPARTMENT

SEE

NOTE

59" MIN.

" M

IN

SEE WATER CLOSET

POSITION NOTE

" M

IN

SELF-CLOSING, 36" WIDE

DOOR

4" MAX.

MI

N.� 6"

MIN.

�6"

9" MIN. HT. X 6" DEEP

TOE CLEARANCE AT

FRONT & AT LEAST

ONE SIDE PARTITION

MIN. CLEAR FLOOR SPACE

X1 & Y1 = REQUIRED

DIMENSIONS WITH TOE

CLEARANCE

X2 & Y2 = REQUIRED

DIMENSIONS W/O TOE

CLEARANCE

X2=66" MIN. CLR.

X1=60" MIN. CLR.

8A - ACCESSIBLE TOILET COMPARTMENT

(FLOOR MOUNTED W.C.)

EQ EQ

30" x 48"

PROVIDE KNEE AND

TOE CLEARANCE BELOW

PER ILLUSTRATION AT

ITEM 10, THIS SHEET

8C - CLEARANCE AT LAVATORY

�18"

60" MIN. CLR.

" M

IN

. C

LR

.MIN. CLEAR FLOOR

SPACE, NO FIXTURES

OR DOOR SWINGS

CAN OVERLAP

SEE WATER CLOSET

POSITION NOTE

8D - CLEARANCE AT TOILET

Y2 =6

5" M

IN

. C

LR

Y1 =5

9" M

IN

. C

LR

8B - ACCESSIBLE TOILET COMPARTMENT

(FLOOR MOUNTED W.C.)

9 - RESTROOM MOUNTING HEIGHTS9 - RESTROOM MOUNTING HEIGHTS

9D - PAPER TOWEL DISPENSER

AND TRASH RECEPTACLES

9C - MIRRORS

9F - DISPENSER LOCATIONS - PROTRUDING TYPE

ACCEPTABLE DISPENSER

LOCATIONS PER ICC A117.1

ACCEPTABLE DISPENSER LOCATIONS

PER ADA-2010 & ICC A117.1

GRAB BARS

9.5 SIZE AND SPACING OF GRAB BARS: THE OUTSIDE DIAMETER OF GRAB BARS SHALL BE 1-1/4" MIN. TO 2" MAX. THE SPACE BETWEEN

THE WALL AND GRAB BAR SHALL BE 1-1/2".

9.6 STRUCTURAL STRENGTH: THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS, AND MOUNTING DEVICES SHALL BE CAPABLE OF SUPPORING A VERTICAL OR HORIZONTAL FORCE OF 250 LBS. APPLIED TO ANY POINT ON THE GRAB BAR. GRAB BARS SHALL NOT

ROTATE IN THEIR MOUNTINGS.

9.7 ELIMINATING HAZARDS: HANDRAILS AND ADJACENT WALLS OR OTHER SURFACES SHALL BE FREE OF SHARP OR ABRASIVE

ELEMENTS. EDGES SHALL BE ROUNDED.

9G - GRAB BARS AT WATER CLOSETS

TOP OF

COUNTERTOP

BOTTOM EDGE

OF REFLECTING

SURFACE

MIRROR

1.

2.

3.

4.

NOTE:

PROVIDE 12" CLEAR AREA ABOVE GRAB BARS, TYPICAL

PROVIDE 1.5" CLEAR AREA BETWEEN GRAB BARS AND ADJACENT ACCESSORIES I.E. SHOWER CONTROLS, SHOWER FITTING, AND

OTHER GRAB BARS

PROVIDE BLOCKING TO SUPPORT MIN. 250 LBS. OF VERTICAL AND HORIZONTAL FORCE

THE REAR GRAB BAR SHALL BE 36" LONG MIN. AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12" MIN. ON ONE

SIDE AND 24" MIN. ON THE OTHER SIDE.

MAX.

12"

MIN.

42"

39" - 41"

54"

FR

ON

T / S

ID

E

RE

AC

H

RA

NG

E

" A

FF

M

AX

TOILET

SEAT HEIGHT

16"-18"

12"

36"

MI

N.18

LINE

OF

WALL

7"-9"

24" MIN.

42" MAX.

" M

IN

1- 1/2

" M

IN

36" MAX.

24" MIN.

MI

N.

" M

AX

TOP OF TOWEL

DISPENSER

T.

O.

C

ON

TR

OL

S

" M

AX

9A - PAPER TOWEL DISPENSER

(UNOBSTRUCTED)

T.

O.

C

ON

TR

OL

S

" M

AX

9B - SOAP DISPENSER

(UNOBSTRUCTED)

" M

AX

" M

AX

" M

AX

NOTE: WATER SUPPLY AND DRAIN PIPES SHALL BE

INSULATED OR OTHERWISE COVERED, AND THERE

SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER

THE LAVATORIES OR SINKS.

10 - SINKS & LAVATORIES KNEE & 10 - SINKS & LAVATORIES KNEE &

TOE CLEARANCETOE CLEARANCE

EQ

EQ 30" x48"

FAUCET SHALL BE

OPERABLE WITH ONE HAND

AND SHALL NOT REQUIRE

TIGHT GRASPING, PINCHING

OR TWISTING OF WRIST

TOP OF COUNTER SURFACE

OR RIM OF SINK,

WHICHEVER IS HIGHER

9"

M

IN

KNEE & TOE

CLEARANCE

" M

IN

" M

AX

8" MIN.

19" MAX.

11" MIN. 6" MAX.

25" MAX.

17" MIN.

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

A0.05.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

A C

C E

S S

IB

IL

IT

Y

G U

ID

E

LI

N

E S

IFC

No. Description Date

CONT. BEAD ACOUSTIC SEALANT

(BOTH SIDES)

1 LAYER 5/8" GYP. BD. ONE SIDE

BATT INSULATION

(WHEN .i IS INDICATED)

METAL STUD

S21

S61

4 1/4"

6 5/8"

NOTES / ALTERNATES:

.i: PROVIDE INSULATION FULL HEIGHT OF PARTITION AS SCHEDULED

.D: EXTEND WALL TYPE TO DECK / ROOF JOIST

PARTITION TYPE S21, S31, S61

PARTITION TYPE S30, S60

PLAN

SILL CONT. BEAD ACOUSTIC SEALANT

(BOTH SIDES)

1 LAYER 5/8" GYP. BD. EACH SIDE

BATT INSULATION

(WHEN .i IS INDICATED)

METAL STUD

S30

S60

NOTES / ALTERNATES:

.i: PROVIDE INSULATION FULL HEIGHT OF PARTITION AS SCHEDULED

.D: EXTEND WALL TYPE TO DECK / ROOF JOIST

PLAN

SILL

S31

3 1/8"

7 1/4"

4 7/8"

CONT. BEAD ACOUSTIC SEALANT

(BOTH SIDES)

2 LAYERS 5/8" GYP. BD. EACH SIDE

BATT INSULATION

(WHEN .i IS INDICATED)

"SOUNDGUARD" SOUND WALL

STC 60

NOTES / ALTERNATES:

WALL TO DECK W/INSULATION AND ACOUSTIC SEALANT AT TOP TRACK

PLAN

SILL

3 5/8"

6 1/8"

GENERAL NOTES:

1.

2.

3.

4.

5.

TOP OF PARTITION FASTENERS: HILTI X-ZF22P8T 0.138 DIA. X

3/4" LONG. POWER DRIVING PINS @ 24" O.C. MIN. (2) FASTENERS

@ EAFH CONNECTION (OR EQUAL)

BOTTOM OF PARTITION FASTENERS: HILTI X-ZF 0.138 DIA. X 3/4"

LONG LOW VELOCITY POWER ACTUATED FASTENERS @ 24"

O.C. (OR EQUAL)

PROVIDE INSULATION AT ALL WALLS INDICATED WITH " i "

CONTRACTOR TO COORDINATE DOOR FRAME THROAT SIZE

WITH PARTITION TYPE

REFERENCE DOOR SCHEDULE FOR DOOR RATING

PARTITION NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

ALL PARTITION SHEATHING TO BE 5/8" GYPSUM BOARD, UNLESS

NOTED OTHERWISE.

ALL PARTITIONS SHALL BE COORDINATED WITH SCHEDULED

FINISHES FOR PARTITION LAYOUT AND REQUIRED

CLEARANCES.

PROVIDE 16 GA. METAL BACKING IN PARTITIONS FOR

CASEWORK, HANDRAILS & ARTWORK HANGING AS INDICATED.

REFER TO INTERIOR ELEVATIONS FOR LOCATIONS AS NEEDED.

FOR INTERIOR FRAMING LIMITING HEIGHTS REFER TO SSMA

TABLES FOR INTERIOR NON-STRUCTURAL NON-COMPOSITE

PARTITIONS.

CONTRACTOR TO RE-COMFIRM STUD SIZING AND SUBMIT

SELECTION CRITERIA FOR REVIEW.

REFER TO FINISH SCHEDULES FOR APPLIED FINISH ON EACH

WALL TYPE.

DRYWALL PARTITION CONTROL JOINTS ARE REQUIRED AT

APPROX. 30'-0" O.C. FOR STRAIGHT AND CONTINUOUS WALLS,

AT OPENING LOCATIONS, OR AS NOTED OTHERWISE ON PLANS.

MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH

SOUND BARRIER PARTITIONS ARE TO AVOID BACK-TO-BACK

DEVICE BOXES. ALL DEVICES ARE TO BE PLACED IN SEPARATE

STUD SPACES TO PROVIDE MIN. 8" SEPARATION. DUCT

PENETRATIONS ARE TO RECEIVE PERIMETER ACOUSTIC

SEALANT BETWEEN DUCT AND WALL FRAMING AND TO EACH

SIDE OF GYPSUM WALLBOARD LAYER MEETING DUCT

SURFACES.

BOTTOM OF (E) CONCRETE DECK IS APPROX. 14' - 0" AFF, VIF.

PARTITION TAG:

SXXi.D#

DESIGNATES MATERIAL

C - CMU / CONCRETE

M - MASONRY

W - WOOD

S - STEEL

NOMINAL STUD SIZE

FINISH O/ STRUCTURE: REFERENCE

TYPES FOR MATERIAL(S)

SOUND ATTENUATION BLANKET / BATT

INSULATION

PARTITION TO DECK / FLOOR / ROOF

WALL ASSEMBLY FIRE RATING

5/8" TYPE 'X' GYP. BOARD

7/8" FURRING CHANNEL W/ 0.150 DIA.

SHOT PINS @16" O.C. TYP.

(E) SOLID GROUTED CMU

PARTITION TYPE HC

CONT. BEAD ACOUSTIC SEALANT

(BOTH SIDES)

1 LAYER 5/8" GYP. BD. ONE SIDE

BATT INSULATION

(WHEN .i IS INDICATED)

6" METAL STUD

WALL TO DECK W/INSULATION AND ACOUSTIC SEALANT AT TOP TRACK

PLAN

SILL

S61

PARTITION TYPE 2S61

1"

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

A0.10.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

IN

T

E R

IO

R

P A

R T

IT

IO

N S

IFC

No. Description Date

PARTITION TYPE SG32

EXISTING FIRE RISER TO REMAIN

EXISTING FIRE HYDRANT ID: 6159

EXISTING FIRE HYDRANT ID: 6161

EXISTING FIRE HYDRANT ID: 6160

EXISTING FIRE LANE, TYP

TYP

20' - 0"

IN

SID

E TURNIN

G R

ADIU

S

R 28

0"

TYP

OUTSIDE TURNING RADIUS

R 48' - 0 " T

YP

W LA GRANGE ST

S

VA

LL

EY

S T

AREA OF CONSTRUCTION

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

A0.11.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

S

IT

E P

LA

N

FO

R R

E

FE

R E

N C

E O

N

LY

IFC

1" = 50'-0"1 SITE PLAN - FOR REFERENCE ONLY

N

F.

E.

C

F.

E.

C

F.

E.

C

F.E.C.

F.

E.

C

F.E.C.

F.E.C.

F.E.C.F.E.C.

F.E.C.

F.E.C.

1 3

A A

C C

D D

E E

F F

G G

H H

J J

21.5

1.5

NIC, TYP

ART

OFFICE

500A

SANDING /

KILN

500B

THEATER

PROP ROOM

505A

OFFICE

505B

BOYS

GIRLS

CLASSROOM

ADA

RESTROOM

504A

HALLWAY

WOMEN

MEN

STORAGE

SENSORY

ROOM

517A

SENSORY

ROOM

STORAGE

516A

CLASSROOM CLASSROOM CLASSROOM

CLASSROOMCLASSROOMCLASSROOM

CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM

506 507 508 509 510 511 512

513514515

501 502 503

HALLWAY

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

PREP AND

STORAGE

PREP AND

STORAGE

PREP AND

STORAGE

710 712 714

600A 601A 602A

600 601 602

JANITOR

SPECIAL

EDUCATION

SPECIAL

EDUCATION

ELECTRICAL

HALLWAY

CONFERENCE

PRODUCTION

WORK ROOM

OFFICE

STORAGE

A/V EQIP AND

STORAGE

610D

610E

610C

610G

610H704

LIBRARY

CONFERENCE

MDF

610B

610A

HALLWAY

CLASSROOM

402 CLASSROOM CLASSROOM CLASSROOM

CLASSROOM CLASSROOM CLASSROOM

808 810 812

709 711 713

WARDROBE &

SUPPLIES

ERR

CLASSROOM

SENSORY RM

401A

STORAGE

802A

STORAGE

401C

GIRLS

700C

BOYS

700B

HANDWASH

700A

HALLWAY

MAINT

401C

ELEC

FCS

CLASSROOM

FACULTY

LOUNGE

SPEECH MATH OFFICE

701 703 705

ERR RR

401B

FACULTY RR

FACULTY RR

707C

707B

CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM

813811809807805803801

CAFETERIA

SERVING

401H

STORAGE

BOYS

GIRLS

KITCHEN

MECHANICAL

401E

SCULLERY

FREEZER

401D

KITCHEN

401B

DRY

STORAGE

VESTIBULE

105A

ENTRY HALL

106A

PRINCIPAL

102F

OFFICE

102E

OFFICE

102D

OFFICE

102C

OFFICEOFFICEOFFICEOFFICE

TOILETTOILETTEACHER'S

LOUNGE

WORK ROOM

102P

102G102H102I102J

CONFERENCE

102L

BOYS COT

GIRLS COT

NURSE

102Q

WOMEN

MEN

VAULT

102M

RECPTION

AND

CLERICAL

102X

WAITING

STORAGE

102W

HALLWAY

102Z

ROBE

STORAGE

101E

CHOIR

PRACTICE

101F

CHOIR

OFFICE

101G

BAND

OFFICE

100B

MUSIC AND

UNIFORMS

100A

BAND ROOM

STORAGE

100JPRACTICE

100H

PRACTICE

PRACTICE

PRACTICE

PRACTICE

PRACTICE

100G

100F

100E

100D

100C

TRANSPORTATION

ROOM

GYMNASIUM

WEIGHT ROOM

203 STORAGE

STORAGE

MAIN GYMNASIUM

200B

200A

HALLWAY

PRACTICE

PRACTICE

PRACTICE

MUSIC AND

STORAGE

101A

101B

101C

HALLWAY

HALLWAY

401C

COOLER

401A

IDF

405C

ROOF

ACCESS

ELEC

GIRLS

STORAGE

308C

GIRLS

LOCKER

ROOM

GIRLS RR

STORAGE

OFFICE FACULTY

RR 308A 308B

MAINT.

STORAGE

309A

WRESTLING

ROOM

STORAGE STORAGE

BOYS RR

BOYS

LOCKER

ROOM

OFFICE

FACULTY RR ELEC

312A

312B 311 312C 314

HALLWAY

300B

HALLWAY

BOYS

PRE-

ENGINEERING

FIRE RISER

ROOM

305B

STORAGE

305A

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

AD1.01.4

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

AD0.12.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

P H

A S

E

D E

M O

O V

E R

A

LL

F

LO

O R

P

LA

N

IFC

N

1/16" = 1'-0"1 PHASE 2B DEMO OVERALL FLOOR PLAN Copy 1 Copy 1

1 3

A A

C C

D D

E E

F F

G G

H H

J J

MECHANICAL EQUIPMENT SPACE

5"

1' -0

5"

1'

-0

5" / 1'-0" 5" / 1'-0"

22' - 11 23/32"

24' - 2"

24' - 2"

NIC, TYP

AD1.20.4

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

AD0.13.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

P H

A S

E

D E

M O

O V

E R

A

LL

R O

O F

P

LA

N

IFC

N

1/16" = 1'-0"1 PHASE 4 DEMO OVERALL ROOF PLAN

F.

E.

C

F.E.C.

F.E.C.

F.E.C.

EXISTING TO BE

DEMOLISHED

EXISTING TO REMAIN

DEMO PLAN LEGEND

? KEYNOTE

EXISTING CONC FLOOR /

SLAB TO BE DEMOLISHED

SHEET NOTES - DEMO PLAN

1.

2.

3.

4.

5.

6.

7.

8.

9.

ALL DIMENSIONS ARE TO STRUCTURAL GRID,

FACE OF MASONRY/CONCRETE, OR FACE OF

STUD, UNO

SCREENED/GREYED OUT LINES REPRESENT

EXISTING WALLS, DOORS, WINDOWS, ETC. TO

REMAIN. PROTECT FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES.

COORDINATE DEMOLITION EXTENTS WITH

NEW PLANS.

SEE ENGINEERING DRAWINGS FOR

ADDITIONAL DEMO, AS APPLICABLE.

REMOVE EXISTING FINISHES THROUGHOUT

AND PREP SURFACES TO RECEIVE NEW

FINISHES AS SCHEDULED.

REPAIR EXISTING FLOORING SUBSTRATE AS

REQUIRED TO RECEIVE NEW FINISHES

INSTALLED PER MANUFACTURER'S

RECOMMENDATIONS.

REPAIR ROOF STRUCTURE WHERE

DEMOLITION OCCURS AT EXISTING FULL

HEIGHT MASONRY WALLS. RE: STRUCTURAL.

REMOVE EXISTING SIGNAGE, DOOR STOPS,

WALL CLOCKS, ETC. WITHIN AREA OF WORK.

DEMO ALL STUD DEMISING WALLS AS

INDICATED BY DASHED LINES.

D D

E E

F F

G G

2.46

2.57

2.46 2.46

2.46 2.46

2.462.46

2.04 2.04 2.04 2.46

2.04

2.46 2.04

2.46

TYP

2.46

2.46

2.04 2.04

2.04

2.46

2.04

2.04

2.04 2.04

2.04

2.46

2.04

2.46

2.04

2.46

LIBRARY

AUDIO & VISUAL STORAGE

OFFICE

WORK ROOM

PRODUCTION

CLASSROOM

HALLWAY

HALLWAY

ELECTRICAL

SPECIAL EDUCATION

SPECIAL EDUCATION

SCIENCE CLASSROOM

SCIENCE CLASSROOM SCIENCE CLASSROOM

SCIENCE CLASSROOM

SCIENCE CLASSROOM

SCIENCE CLASSROOM

PREP AND STORAGE PREP AND STORAGE PREP AND STORAGE

2.08

2.41 2.14

2.14

2.14

2.46

2.46

2.14

2.46

2.46

TYP

TYP

2.31

TYP

2.31

TYP

TYP

OFFICE

MDF 2.04

NIC

NIC

2.312.312.20

2.57

2.01

2.27

TYP

2.56

TYP

2.27

TYP

2.50

2.46

TYP

2.57

2.01

2.01

2.34

2.27

TYP

2.34

2.27

TYP

2.40

2.14

2.64

2.342.34

2.01

2.27

TYP

2.27

TYP

2.57

TYP

2.27

TYP

2.86

2.46

TYP

2.46

TYP

2.13

JANITOR

2.14

2.01

TYP

2.46

TYP

2.34

2.14

2.14

2.14

TYP

2.54

2.54

2.57 2.142.20

2.27

2.27

2.14

2.14

2.08

2.70

2.14

2.57

2.27

TYP

2.34

2.46

2.46

2.49 2.49

2.49

2.49 2.49 2.49 2.49

2.49

2.49

2.49

2.46

2.26

2.26

2.01

2"

28' - 11 1/2"

VIF

6' - 5" MAX

TYP

2.46

2.72

2.72

TYP

2.34

2.34

2.32

TYP

2.32

TYP

VIF

9.17

4' - 0" 4' - 0" 9.17 4' - 0" 4' - 0" 4' - 0"

9.17

2.32

TYP

2.40

TY

P

1'

- 0

2.46

2.46

A5.10.4

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

AD1.01.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

P H

A S

E

D E

M O

F

LO

O R

P

LA

N

IFC

KEYNOTE LEGENDKEYNOTE LEGEND

NO. KEYNOTE / REFERENCE NOTE

2.01 (E) CONSTRUCTION, PRESERVE AND

PROTECT. REPAIR DAMAGED AREAS TO

ORIGINAL STATE.

2.04 DEMO (E) TOILET(S) AND/OR SINK(S), RE:

PLUMBING DWGS.

2.08 NEW OPENING IN (E) BLOCK WALL. INSTALL

NEW FRAMING PER STRUCTURAL DWGS

PRIOR TO CUTTING OPENING. LOCATE

OPENING AT (E) MORTAR BED BETWEEN

MASONRY UNITS. TYP AT ALL NEW BLOCK

WALL OPENINGS. RE: STRUCTURAL DWGS.

2.13 DEMO (E) ELECTRICAL PANEL, RE:

ELECTRICAL DWGS.

2.14 DEMO (E) DOOR AND FRAME.

2.20 DEMO (E) DRINKING FOUNTAIN, RE:

PLUMBING DWGS.

2.26 (E) LOCKERS TO BE RELOCATED, REMOVE

(E) ANGLED METAL TOP AND PREP FOR

NEW SOFFIT; RE: NEW PLANS.

2.27 REMOVE ALL (E) FURNITURE AND

EQUIPMENT FOR STORAGE OR DISPOSAL,

CONFIRM WITH DISTRICT.

2.31 (E) LOCKERS TO REMAIN, PROTECT IN

PLACE. REMOVE (E) ANGLED METAL TOP

AND PREP FOR NEW SOFFIT, RE: NEW

DWGS.

2.32 DEMO AND DISPOSE OF ALL (E) FLOOR

COVERINGS AND WALL BASE, PREP

SURFACES TO RECEIVE NEW FINISHES PER

MFR SPEC.

2.34 DEMO (E) DOOR/FRAME/SIDELITE.

TRANSITE PANELS HAVE KNOWN

ASBESTOS, CONTRACTOR TO ABATE PER

EPA REQUIREMENTS, REFER TO ASBESTOS

BUILDING MATERIAL INSPECTION REPORT

IN SPECIFICATIONS BOOK.

2.40 DEMO (E) GREENHOUSE STOREFRONT

SYSTEM; PREP FOR REPLACEMENT.

2.41 DEMO AND DISPOSE OF (E) STOREFRONT.

SEALANT AT DOOR HAS KNOWN ASBESTOS,

CONTRACTOR TO ABATE PER EPA

REQUIREMENTS, REFER TO ASBESTOS

BUILDING MATERIAL INSPECTION REPORT

IN SPECIFICATIONS BOOK.

2.46 DEMO (E) BUILT-IN MILLWORK AND ANY

ASSOCIATED PLUMBING AND ELECTRICAL,

TYP, VIF.

2.49 REMOVE (E) WALL MOUNTED TACK BOARDS

/ MAP RAILS FOR STORAGE OR DISPOSAL,

CONFIRM WITH DISTRICT, VIF.

2.50 DEMO (E) SURFACE MOUNTED FIRE

EXTINGUISHER AND CABINET.

2.54 DEMO (E) CARD READER, RE: TECHNOLOGY

DWGS.

2.56 DEMO (E) POWER POLES, RE: ELECTRICAL

DWGS.

2.57 DEMO (E) CONCRETE FLOOR/SLAB FOR

NEW INFRASTRUCTURE, RE: STRUCTURAL,

PLUMBING, ELECTRICAL AND TECHNOLOGY

DWGS, VIF.

2.64 (E) PRINTER TO BE STORED AND

REINSTALLED AT COMPLETION OF PHASE,

VIF.

2.70 (E) GIANT BRICK WING WALL, PAINT P-5,

PREP AND PRIME PER MFR

REQUIREMENTS.

2.72 REMOVE AND REINSTALL (E) LOCKERS AS

NEEDED, RE: PLUMBING DWGS, VIF.

2.86 DEMO (E) WALL MOUNTED IT RACK, RE:

TECHNOLOGY DWGS.

9.17 REMOVE (E) BASE, TRIM, WALL

PROTECTION, CORNER GUARDS, ETC. MIN

4' ON EITHER SIDE OF OPENING, VIF;

PROVIDE NEW FINISHES TO MATCH AND

COORDINATE W/NEW FINISHES IN

CLASSROOM ALCOVE. ENSURE SMOOTH

TRANSITION BETWEEN NEW AND (E)

FINISHES, VIF.

A

B

C

D

E

F

G

H

J

KEY PLAN

1/8" = 1'-0"1 PHASE 4 DEMO FLOOR PLAN

N

SHEET NOTES - DEMO PLAN

1.

2.

3.

4.

5.

6.

7.

8.

9.

ALL DIMENSIONS ARE TO STRUCTURAL GRID,

FACE OF MASONRY/CONCRETE, OR FACE OF

STUD, UNO

SCREENED/GREYED OUT LINES REPRESENT

EXISTING WALLS, DOORS, WINDOWS, ETC. TO

REMAIN. PROTECT FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES.

COORDINATE DEMOLITION EXTENTS WITH

NEW PLANS.

SEE ENGINEERING DRAWINGS FOR

ADDITIONAL DEMO, AS APPLICABLE.

REMOVE EXISTING FINISHES THROUGHOUT

AND PREP SURFACES TO RECEIVE NEW

FINISHES AS SCHEDULED.

REPAIR EXISTING FLOORING SUBSTRATE AS

REQUIRED TO RECEIVE NEW FINISHES

INSTALLED PER MANUFACTURER'S

RECOMMENDATIONS.

REPAIR ROOF STRUCTURE WHERE

DEMOLITION OCCURS AT EXISTING FULL

HEIGHT MASONRY WALLS. RE: STRUCTURAL.

REMOVE EXISTING SIGNAGE, DOOR STOPS,

WALL CLOCKS, ETC. WITHIN AREA OF WORK.

DEMO ALL STUD DEMISING WALLS AS

INDICATED BY DASHED LINES.

2x4 SUSPENDED

CEILING SYSTEM TO

BE DEMOLISHED

DEMO CEILING PLAN LEGEND

GYP BD CEILING TO BE

DEMOLISHED

LIGHT FIXTURE TO BE

DEMOLISHED

D D

E E

F F

G G

SCIENCE CLASSROOM

SCIENCE CLASSROOM

SCIENCE CLASSROOM

SCIENCE CLASSROOM

600 SCIENCE CLASSROOM

SCIENCE CLASSROOM

PREP & STORAGE PREP & STORAGE PREP & STORAGE

600A 600B 600C

MECH & ELECTRICAL

SPECIAL EDUCATION

SPECIAL EDUCATION

JANITOR

HALLWAY

HALLWAY

AUDIO & VISUAL STORAGE

LIBRARY

610J 610H

OFFICE

610G

WORK ROOM

2.15

2.15

TYP

2.85

2.15

2.15 2.15

2.15

2.15

CONFERENCE

2.15

2.15

2.15

2.15

NIC

NIC

NIC

NIC

2.15

2.15

2.152.15

2.15

2.15

2.15 2.152.15

2.15

2.152.01 2.01

OFFICE

2.15

2.15

MDF

A5.10.4

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

AD1.11.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

P H

A S

E

D E

M O

C E

IL

IN

G P

LA

N

IFC

KEYNOTE LEGENDKEYNOTE LEGEND

NO. KEYNOTE / REFERENCE NOTE

2.01 (E) CONSTRUCTION, PRESERVE AND

PROTECT. REPAIR DAMAGED AREAS TO

ORIGINAL STATE.

2.15 DEMO (E) LIGHT FIXTURES, RE: ELECTRICAL

DWGS.

2.85 DEMO (E) EXTERIOR SOFFIT, VIF.

A

B

C

D

E

F

G

H

J

KEY PLAN

1/8" = 1'-0"1 PHASE 4 DEMO RCP

N

SHEET NOTES - DEMO ROOF

2.

3.

4.

5.

6.

7.

8.

DEMO PLANS PROVIDED AS A CONVENIENCE

TO THE CONTRACTOR. CONTRACTOR IS

RESPONSIBLE FOR ALL DEMOLITION

NECESSARY FOR INSTALLATION OF NEW

WORK.

THE GENERAL CONTRACTOR SHALL FIELD

VERIFY ALL DIMENSIONS AND CONDITIONS

PRIOR TO THE INSTALLATION OF THE NEW

ROOFING SYSTEM. NOTIFY THE ARCHITECT

OF ANY DISCREPANCIES PRIOR TO

PROCEEDING.

THE BUILDING MAY LIKELY BE OCCUPIED

DURING DEMOLITION AND INSTALLATION OF

THE NEW ROOFING SYSTEM. COORDINATE

ACCESS W/ OWNER.

COORDINATE REMOVAL AND INSTALLATION

OF ROOF TOP STRUCTURES AND EQUIPMENT

W/ OTHERS AS REQUIRED. CONTRACTOR IS

RESPONSIBLE FOR EXTENDING ALL UTILITIES

AND DUCTWORK AS REQUIRED.

MAINTAIN BUILDING IN A WEATHER-TIGHT

CONDITION AGAINS INCLEMENT WEATHER AT

ALL TIMES.

VERIFY IN FIELD ALL NEW OPENINGS COMPLY

WITH STRUCTURAL DRAWINGS.

REPAIR ROOF STRUCTURE AS REQUIRED

WHERE EQUIPMENT REMOVED, RE:

STRUCTURAL.

SEE ENGINEERING DRAWINGS FOR

ADDITIONAL DEMO, AS APPLICABLE.

D D

E E

F

G

5.02

2.60

2.60

5.02

5.02

2.16 2.16

2.16 2.16

2' - 2"

3'

- 0

2.18

2.28

2' - 2"

3'

- 0

2' - 2" 3'

- 0

2' - 2"

3'

- 0

2' - 2"

3'

- 0

2' - 2"

3'

- 0

2.28 2.28

2.28 2.28 2.28

33' - 0" 33' - 6" 11' - 6"8' - 9"

8' - 9" 33' - 0" 33' - 6" 11' - 6"

EXISTING TO BE

DEMOLISHED

EXISTING TO REMAIN

DEMO PLAN LEGEND

? KEYNOTE

EXISTING CONC FLOOR /

SLAB TO BE DEMOLISHED

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

AD1.20.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

P H

A S

E

D E

M O

R O

O F

P

LA

N

IFC

KEYNOTE LEGENDKEYNOTE LEGEND

NO. KEYNOTE / REFERENCE NOTE

2.16 DEMO (E) ROOF DRAIN AND PIPING DOWN

TO TERMINATION AT CONCRETE SLAB ON

GRADE, VIF, ENLARGE OPENING FOR NEW

ROOF AND OVERFLOW DRAIN, RE:

PLUMBING DWGS.

2.18 DEMO (E) BALLASTED TPO ROOF DOWN TO

STRUCTURAL CONCRETE DOUBLE TEES IN

PREPARATION FOR NEW ROOF, VERIFY

EXTENT IN FIELD.

2.28 NEW OPENING IN (E) ROOF SLAB, MAX

OPENING 30" x 40". INSTALL NEW SUPPORT

FRAMING PER STRUCTURAL DWGS PRIOR

TO CUTTING OPENING. TYP AT ALL ROOF

SLAB OPENINGS, RE: STRUCTURAL. VERIFY

EXACT LOCATIONS IN THE FIELD, RE:

MECHANICAL DWGS FOR NEW EQUIPMENT

LOCATIONS.

2.60 DEMO (E) ROOF TOP MECHANICAL

EQUIPMENT, VIF. RE: MECHANICAL DWGS.

5.02 RE: STRUCTURAL FOR NEW STEEL OVER

OPENING IN ROOF STRUCTURE WHERE

EQUIPMENT DEMOLISHED, VIF; RE:

STRUCTURAL DWGS.

A

B

C

D

E

F

G

H

J

KEY PLAN

N

1/8" = 1'-0"1 PHASE 4 DEMO ROOF PLAN

F.

E.

C

F.

E.

C

F.E.C.

F.

E.

C

F.E.C.

F.E.C.

F.E.C.F.E.C.

F.E.C.

F.E.C.

F.E.C.

1 3

A A

C C

D D

E E

F F

G G

H H

J J

21.5

1.5

CLASSROOM

CLASSROOM

CLASSROOM

FACULTY LOUNGE

SPEECH

MAINT.

SENSORY

802A

401A

NIC, TYP

ART

STORAGE

KILN

THEATER

PROP STORAGE

501B

BOYS

600B

GIRLS

600C

CLASSROOM

HALLWAY

ELEC.

IDF

WOMEN'S RR

MEN'S RR

SENSORY

ROOM

CLASSROOM CLASSROOM CLASSROOM

CLASSROOMCLASSROOMCLASSROOM

CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM

502 504 506 508 510 512 514

511509507

604 606 608

HALLWAY

HALLWAY

CLASSROOM

402 CLASSROOM

CLASSROOM CLASSROOM

810 812

709 711 713

WARDROBE &

SUPPLIES

ERR

CLASSROOM

SENSORY RM

STORAGE

STORAGE

401C

GIRLS

700C

BOYS

700B

HANDWASH

700A

HALLWAY

MAINT

401C

ELEC

FCS

CLASSROOM

SPEECH MATH OFFICE

701 703 705

ERR RR

401B

FACULTY RR

FACULTY RR

707C

707B

CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM CLASSROOM

813811

809807805803801

CAFETERIA

SERVING

401H

STORAGE

BOYS

GIRLS

KITCHEN

MECHANICAL

401E

SCULLERY

FREEZER

401D

KITCHEN

401B

DRY

STORAGE

VESTIBULE

105A

ENTRY HALL

106A

PRINCIPAL

102F

OFFICE

102E

OFFICE

102D

OFFICE

102C

OFFICEOFFICEOFFICEOFFICE

TOILETTOILETTEACHER'S

LOUNGE

WORK ROOM

102P

102G102H102I102J

CONFERENCE

102L

BOYS COT

GIRLS COT

NURSE

102Q

WOMEN

MEN

VAULT

102M

RECPTION

AND

CLERICAL

102X

WAITING

STORAGE

102W

HALLWAY

102Z

ROBE

STORAGE

101E

CHOIR

PRACTICE

101F

CHOIR

OFFICE

101G

BAND

OFFICE

100B

MUSIC AND

UNIFORMS

100A

BAND ROOM

STORAGE

100JPRACTICE

100H

PRACTICE

PRACTICE

PRACTICE

PRACTICE

PRACTICE

100G

100F

100E

100D

100C

TRANSPORTATION

ROOM

GYMNASIUM

WEIGHT ROOM

203 STORAGE

STORAGE

MAIN GYMNASIUM

200B

200A

HALLWAY

PRACTICE

PRACTICE

PRACTICE

MUSIC AND

STORAGE

101A

101B

101C

HALLWAY

401C

COOLER

401A

IDF

405C

ROOF

ACCESS

ELEC

GIRLS

STORAGE

308C

GIRLS

LOCKER

ROOM

GIRLS RR

STORAGE

OFFICE FACULTY

RR 308A 308B

MAINT.

STORAGE

309A

WRESTLING

ROOM

STORAGE STORAGE

BOYS RR

BOYS

LOCKER

ROOM

OFFICE

FACULTY RR ELEC

312A

312B 311 312C 314

HALLWAY

300B

HALLWAY

BOYS

PRE-

ENGINEERING

FIRE RISER

ROOM

305B

STORAGE

305A

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

602A

602B

501A

PROP ROOM

CHANGING

STORAGE

STORAGE

505A

HANDWASH

600A

SENSORY

ROOM

SENSORY

ROOM

MASTER BED

LIBRARY

MDF

STORAGE

601C CLASSROOM

CLASSROOM

OFFICE

601A

CLASSROOM

HALLWAY

HALLWAY

WORK ROOM

MAINTENANCE

TECH

CLASSROOM

ELECTRICAL

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

STORAGE &

PREP

SCIENCE

CLASSROOM

SCIENCE

CLASSROOM

A1.01.4

WORK ROOM

601B

REVISIONS

SHEET ISSUE DATE

SUBMITTAL

PROJECT NUMBER

STAMP:

SHEET

OW

NE

R

PR

OJ

EC

T

PR

OJ

EC

T

AD

DR

ES

S

SH

EE

T

NA

ME

CONSULTANT:

1335 N. MAIN STREET

MERIDIAN, ID 83642

208-649-8306 www.studioharchitects.com

P H

A S

E

A1.00.4

W E

S T

A D

A S

C H

O O

L D

IS

T

R

IC

T

LA

K

E H

A Z

E L

M .S

. R E

N O

V A

T

IO

N

10/31/25

W

. L A

G R

AN

G

E

ST

BO

IS

E, ID

23-61

O V

E R

A

LL

F

LO

O R

P

LA

N P

H

IFC

N

1/16" = 1'-0"1 OVERALL FLOOR PLAN PHASE 4A

F.E.C.

F.E.C.

F.

E.

C

F.

E.

C

F.E.C.

F.

E.

C

F.

E.

C

F.

E.

C

F.

E.

C

F.

E.

C

SHEET NOTES - FLOOR PLAN

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

ALL DIMENSIONS ARE TO STRUCTURAL GRID,

FACE OF MASONRY/CONCRETE, OR FACE OF

STUD, UNO

RE: CODE AND OCCUPANCY PLANS FOR

REQUIRED FIRE RATINGS AND SMOKE

PARTITIONS.

CONTRACTOR TO VERIFY ALL COLUMN AND

ROOF DRAIN FURR OUTS IN…

This is the start of the file's text. The full file is on GovTribe.