3500.291.pdf
PDF 444 KB Posted
- Attached to
- SCRO-REPLACE BOILERS BUILDING 346 Federal contract opportunity
- Solicitation number
- 15B50023Q00000004
About this file
This document is a product submittal for XTherm Type WH water heaters to be used in replacing boilers at Building 346 for the Department of Justice Bureau of Prisons South Central Regional Office under solicitation number 15B50023Q00000004. The submittal provides specifications for three water heater models in the 1005A to 2005A size range, including dimensions, power requirements, recovery rates, clearances, and venting and control options. Required features include a copper or cupronickel heat exchanger, ASME stamping, low NOx emissions certification, and touchscreen or remote control interfaces.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| QUESTIONS.pdf | ||
| Amendment 00004.pdf | ||
| Amendment 004- Building 346 Replace Boilers SOW_1.pdf | ||
| Amendment 00003.pdf | ||
| Building 346 Replace Boilers SOW_1 - REVISED.pdf | ||
| Site Visit 9-5-2023.pdf | ||
| Amendment 00002.pdf | ||
| Boiler Pictures.pdf | ||
| QUESTIONS.pdf | ||
| Amendment 00001.pdf | ||
| 04. Building 346 Replace Boilers SOW_1.pdf | ||
| BRQ 15B50023Q00000004.pdf | ||
| INSTRUCTIONS TO OFFERORS.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Part no.: 241872 Rev. 1 Effective: 09-01-20 Replaces 3500.291B Page 1 of 4
Product Submittal for XTherm®- Type WH
Water Heater
Models 1005A-2005A
Location:
Contractor:
Gas Type: Natural Gas Propane
97% Thermal efficiency at full rate
100% Factory fire-tested
VERSA IC® modulating controller with 7" color touchscreen display
Raymote™ remote connectivity provided standard
Soft-start ignition; 60% minimum fire
Full safety diagnostics with history
Status display lights
Cascade up to 8 heaters – no external sequencer required
Modbus RTU BMS Port
Maximum outlet water temperature: 180°F (82°C)
Maximum tank setpoint: 160°F (71°C)
Limited 25-year thermal shock warranty
Limited 5-year copper/10-year cupronickel primary heat exchanger warranty
Limited 10-year secondary heat exchanger warranty
SCAQMD Rule 1146.2 certified, Low NOx < 20 ppm
Must be used in conjunction with a storage tank for proper operation
Proudly assembled in the USA
Date:
Equipment Tags:
Model:
Prepared by:
Job:
Engineer:
Notes:
Indoor Outdoor
15B50023Q00000004 bop37573 Highlight
Part no.: 241872 Rev. 1 Effective: 09-01-20 Page 2 of 4
Job:
Features and Options
Heat Exchanger
Q Bronze headers
Q ASME HLW stamped; 160 PSIG MAWP
Q National board registered
Q Fin tubing
Copper (standard)
A-3 cupronickel
Q ASME powder-coated tube sheet
Q Silicone high-temp O-Rings
Q ASME pressure relief valve
125 PSIG (standard)
____PSIG (optional)
Q Air bleed valve, manual (2)
Q T&P gauge
Q Four-pass primary heat exchanger
Q Secondary stainless steel condensing heat exchanger - U stamped
Q Stainless steel evaporator plate
Q Boiler pump: bronze, 120V, 1Ø, 60Hz
Q Water hardness:____________ GPG
Power
Q 120V, 60Hz, 1Ø, power supply
Q 120/24V, 60Hz, transformer
Control
Q VERSA IC® built-in controller
Q 7" color HD touchscreen display
Q Raymote™ Wi-Fi remote connectivity
Q Cascade up to 8 heaters
Q Ignition module
3-Try (standard)
C-6 Single-try
Q Remote flame sensor
Q Fixed high limit, manual reset, 200ºF
Q On/off power switch
Q Flow switch
Q Blocked vent pressure switch
Q Freeze protection
Q Alarm dry contact
Q Pump outputs – pilot duty system
Q Programmable pump time delays
Q Water temperature sensor 10KΩ (2 mtd, 1 loose, 1 well)
Q Cold water protection
Q Blocked condensate switch
Q Modbus RTU BMS Port (Up to 115K baud rate, see Cat. 5000.73)
B-85 BMS Gateway, Modbus RTU to Modbus TCP, N2 Metasys, BACnet IP, or BACnet MS/TP
B-86 BMS Gateway, Modbus RTU to LonWorks
Burner
Q Hot surface ignition (HSI)
Q Radially-fired knitted burner
Gas Train
Q Fuel
Natural gas
Propane (minimum grade HD-5)
Q Dual-seat combination valve
Q Electronic modulating firing mode (WH7)
Construction
Q Indoor/outdoor construction
Q Enclosed front controls
Q PolyTuf powder coat finish
Q Rear connections (water, gas, vent, combustion air, condensate drain)
Q Design certified ANSI Z21.10.3/CSA 4.3
Q CSA Low-lead certified ≤ .25% lead
Q Front connection low-voltage wiring
Venting, cat IV
D-11 Vent termination, outdoor
D-15 Vent termination, sidewall
D-18 Adapter, boiler flue
D-19 Adapter, vent termination
D-32 Adapter, PVC vent, with vent temp limit, max return temp 170ºF (Factory-mounted only)
D-33 Adapter, CentrothermTM polypro vent, with vent temp limit, max return temp 190ºF (shipped loose)
D-37 Motorized combustion air damper
Options
B-31 Sensor well assembly (can be used for tank or system sensor)
E-5 Boiler alarm with 4" bell factory mounted shipped loose
E-15 Alarm with buzzer factory mounted shipped loose
F-10 Low water cut-off, manual reset & test button
I-5 High limit, adj. manual reset, 200ºF max
I-13 High limit, adj. auto reset, 200ºF max
I-14 High limit, adj. auto reset, 180ºF max
I-20 High limit, adj. manual reset, 180ºF max
M-1 Safety valve, motorized
M-10 Safety valve, solenoid
M-15 Safety valve, vent valve (requires M-1 or M-10)
S-1 Low gas pressure switch, manual reset
Z-4 T & P relief valve
Z-9 Thermometer
Z-12 Condensate treatment kit
TempTracker Mod+ Hybrid multi-unit controllers
(shipped loose)
B-36 2-4 heaters
B-37 5-10 heaters
B-38 11-16 heaters
B-39* EMS 4-20 mA remote setpoint interface
B-62* BACnet interface module (*requires B-36 to B-38)
Additional options or accessories
Part no.: 241872 Rev. 1 Effective: 09-01-20 Page 3 of 4
Job:
(1) For natural gas. Propane all sizes 1" NPT.
Ratings shown are for elevations up to 4,500 ft. De-rate above 4,500 ft; consult factory. No hardware changes required below 10,000 ft.
For direct vent applications, please contact the factory about relocating the pump.
CLEARANCES
Heater Side Minimum Clearances from
Combustible Surfaces
in. (mm)
Minimum Service Clearance
in. (mm)
Floor 0 0
Rear 12" (305) 36" (914)
Right Side 1" (25) 24" (610)
Left Side 1" (25) 1" (25)
Top Unobstructed 0
Front Open 24" (610)
Vent 1" (25) 1" (25)
* Separate power connections are factory-supplied and separate supply breakers must be field-supplied.
** Current draw is for heater only (Supply breaker must have delayed trip).
POWER REQUIREMENTS – AMPS*
Model
(WH7-)
Heater Amp
Draw*
Pump Amp Draw*
Soft 1-4 Gr.
Medium 5-15 Gr.
Hard 16-25 Gr.
1005A 12** 10 10 14
1505A 12** 10 14 17
2005A 18** 17 17 N/A
Model
(WH7-)
MBTUH (kW/h) Dimensions - inches (mm) Ship Weight
Lbs. (Kg)Input Output B Height D E F G(1)
NPT
K
Flue Ø L M N C/A Ø P R V Y
1005A
(293)
(284) 55-1/4 (1403)
(1143)
(194)
(940)
1-1/4 (32)
(152)
(1041)
11-1/2 (292)
(152)
47-1/8 (1197)
8-5/16 (211)
(330)
6-1/4 (159)
(483)
1505A (440)
(426)
67-1/8 (1705)
(1448)
(1499)
38-5/8 (981)
1-1/4 (32)
(203)
(1346)
12-5/8 (321)
(203)
59-1/8 (1197)
8-3/16 (208)
(330)
6-1/4 (159)
(560)
2005A (586)
(568)
81-1/8 (2061)
(1803)
(1829)
39-5/8 (1007)
(50)
(203)
65-1/2 (1664)
12-5/8 (321)
(203)
73-1/8 (1857)
8 3/16 (208)
(254)
6-1/2 (165)
(663)
*NOTE: Must be used in conjunction with storage tank for proper operation.
bop37573 Highlight
Part no.: 241872 Rev. 1 Effective: 09-01-20 Page 4 of 4
Job:
Model RECOVERY RATES (GPH) at stated ΔT (°F) (L/H)
20°F 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F
1005A
(22231)
(14819)
(11113)
(9232)
(7411)
(6351)
(5556)
(4939)
(4447)
(4042)
1505A
(33379)
(22254)
(16689)
(13351)
(11125)
(9535)
(8346)
(7419)
(6677)
(6068)
2005A 11752
(44486)
(29654)
(22243)
(17795)
(14827)
(12711)
(11121)
(9883)
(8895)
(8089)
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 www.raypak.com bop37573 Highlight
| Date: 09/08/2023 |
| Job: |
| Location: 344 Marine Forces Drive, Grand Prairie TX 75051 |
| Equipment Tags: |
| Engineer: |
| Contractor: |
| Model: 1505A |
| Notes: |
| Prepared by: |
| Indoor: On |
| Outdoor: Off |
| Gas Type Natural Gas: On |
| Propane: Off |
| Copper standard: On |
| A3 cupronickel: Off |
| 125 PSIG standard: On |
| undefined: |
| Boiler pump bronze 120V 1Ø 60Hz: |
| 3Try standard: On |
| C6 Singletry: Off |
| Product Submittal for XTherm Type WH: 15B50023Q00000004 |
| B85 BMS Gateway Modbus RTU to Modbus: On |
| B86 BMS Gateway Modbus RTU to LonWorks: Off |
| Natural gas: On |
| Propane minimum grade HD5: Off |
| D11: Off |
| D15: Off |
| D18: Off |
| D19: Off |
| D32: Off |
| D33: Off |
| D37 Motorized combustion air damper: Off |
| B31: Off |
| E5: Off |
| E15: On |
| F10: On |
| I5: On |
| I13: Off |
| I14: Off |
| I20: Off |
| M1: Off |
| M10: On |
| M15: Off |
| S1: On |
| Z4: On |
| Z9: On |
| Z12: Off |
| factory mounted: Off |
| factory mounted_2: Off |
| shipped loose: Off |
| shipped loose_2: Off |
| B36: Off |
| B37: Off |
| B38: Off |
| B39: Off |
| B62: On |
| Additional options or accessories: |
| undefined_2: |
| Product Submittal for XTherm Type WH_2: |
| 1005A: Off |
| 1505A: On |
| 2005A: Off |
| 1005A_2: Off |
| 1505A_2: On |
| 2005A_2: Off |
| Job_2: |
| 1005A_3: Off |
| 1505A_3: On |
| 2005A_3: Off |
File details come from the government source that posted it. Updated .