This document is a Sources Sought Notice for a federal contract opportunity related to the Design-Bid-Build, FFG-62 Land Based Engineering Site project at the Philadelphia Navy Yard Annex in Philadelphia, PA.
The notice seeks information from commercially available and interested suppliers capable of providing various products and equipment required for this project, including card readers, power supply enclosures, access control system modules, request to exit devices, electric strikes, translucent wall panels, roof enclosures, fire alarm control panels, flood doors, thermal breaks, fire alarm radio transmitters, and fuel oil system equipment. The government is specifically interested in understanding the availability and adequacy of potential sources for these items prior to determining the acquisition method. Interested vendors are requested to submit a capabilities statement package of no more than 5 pages by Friday, May 10, 2024 at 2:00 PM Eastern Daylight Time. Late responses will not be considered.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAGNASPHERE CORP. | 23777 Stone Ridge Dr., Suite 160, Waukesha, WI 53188 tel. 262.347.0711 | fax 262.347.0710 | www.MAGNASPHERE.com
MSS Standard Series Product Sheet Security Contacts have been made with a decades-old technology called the Reed switch.
Reed switches have three inherent weaknesses when used in security contacts. They are (1) Easily defeated with magnets, (2) Prone to permanent contact weld failure (from lightning and power surges), and (3) fragile (made mostly of glass, they are subject to damage even when packaged as security contacts).
The MAGNASPHERE line of security sensors provides a solution to all of these issues.
Utilizing the the patented, revolutionary MAGNASPHERE® BMS switch renders the MSS products virtually unbreakable, and highly resistant to permanent contact welding and outsider magnet defeat, allowing MAGNASPHERE to offer a lifetime replacement warranty.
MSS contacts are available in both the traditional Closed Loop (contact closed when magnet is present) as well as the more Secure Open Loop (contact open when magnet is present) electrical configuration. This is the same configuration required for other life safety devices such as smoke and fire alarms, and has long been the recommend configuration by most knowledgeable security professionals.
FEATURES
• Made with MAGNASPHERE® BMS switch technology
• Won't break
• Resistant to contact welding
• Resistant to outside defeat
• Security industry's BEST warranty
• Universal mounting
• Cost competitive
• Increases RMR
Concealed/Recessed
Surface Mount
Overhead Door
Wireless
PATENTED DESIGN
#5977873, #RE39731, #6506987, #6303845, #6603378, and Patents Pending
Bierman, Daniel Cloud
Door Frame
Door Magnet
CLOSED
SECURE: NO ALARM
Door Magnet
NO ALARM
Door Frame
Door Magnet
CLOSED
Door Opened
Door Frame
CLOSED
FAILED: NO ALARM
D ef ea t
M ag ne t
FAILED: NO ALARM
Door Opened
Door Frame
WELDED
CLOSED
Reed contacts operate on magnetic fields.
Most contacts are Closed in the secure position (Closed Loop) when the door is closed and the magnet is near the switch.
When closed reed contacts are exposed to power surges such as lightning strikes, they are prone to permanent contact welding.
Introducing a defeat magnet OUTSIDE the door will keep the reed contacts closed, allowing an intruder to enter without alerting the security system.
They FAIL SECURE.
Reed switch contacts are globally magnetic:
they will respond to the strongest magnetic field anywhere around the contact –– not solely to the door magnet. When compromised, reed contacts will still send secure signals.
Reed contacts operate by magnetic induction, so they are not attracted to the door magnet.
Once contacts have welded closed, they remain in that state though the door is open.
They FAIL SECURE.
Security contacts are made with a decades-old technology called the Reed switch.
Reed switches have three inherent weaknesses when used in security contacts: (1) Easily defeated with magnets,
(2) Prone to permanent contact weld failure (from lightning and power surges), and (3) fragile (made mostly of glass, they are subject to damage even when packaged as security contacts).
www.MAGNASPHERE.com© MAGNASPHERE CORP.
MAGNASPHERE®
Reed vs.
MAGNASPHERE security sensors' magnet ball contact is open in the secure position (Open Loop) when the door is closed and the door magnet is near the switch.
MAGNASPHERE Security Sensors are Open Loop and highly resistant to contact welding from power surges and lightning strikes.
A defeat magnet introduced OUTSIDE the door will have no effect on the ball contact. When the door is opened, the contact will close, and the SYSTEM
WILL ALARM.
Because the magnet ball contact will not weld, when the door is opened the contact will close and the SYSTEM
WILL ALARM.
MAGNASPHERE’s contact is a spherical magnet and operates in a defined activation zone directed toward the door magnet.
The patented, award-winning MAGNASPHERE switch technology was designed as a security device which over comes the deficiencies of reed contacts. The MAGNASPHERE switch is (1) Resistant to magnetic defeat and tamper, (2) Resistant to permanent contact welding from lightning and power surges, and (3) Robust, all metal welded construction is virtually unbreakable.
www.MAGNASPHERE.com© MAGNASPHERE CORP.
MAGNASPHERE®
Reed vs.
The Door is Closed
OPEN
SECURE: NO ALARM
The Door is Closed
OPEN
NO ALARM
ALARM
The Door is Open
CLOSED D
ef ea t
M ag ne t
ALARM
The Door is Open
CLOSED
File details come from the government source that posted it. Updated .