A1_Lead_Paint_Test_Results_0001.pdf

PDF 174 KB Posted

Attached to
Tyzack Pumping Plant Regulating Tank Coating
Solicitation number
140R4021R0020
Issued by

About this file

This analytical report details lead testing results for paint chip samples collected from the Red Fleet Dam facility. Testing was conducted for two samples from the regulating tank and surge tank locations, with lead content measured at 3.044% and 5.846% respectively using NIOSH Method 7300 modified for paint. The samples exceeded the instrument linear range requiring 10x and 50x dilutions and higher reporting limits.

The related federal contract opportunity is for coating the regulating tank at the Tyzack Pumping Plant. The solicitation was issued by the Bureau of Reclamation for an unknown contract value and period of performance. Response and award dates were not provided. The opportunity description matches the location and work addressed in the analytical test results.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ANALYTICAL REPORT

Darin Breunig U.S. Bureau of Reclamation 125 South State St.

A/P Dept.

Salt Lake City, UT 84138

Phone:

E-mail:

(385) 285-2285 dbreunig@usbr.gov

Report Date: June 28, 2018

Project Manager: Rand Potter

Workorder: 34-1817862

Purchase Order:

Client Project ID: Red Fleet Dam 061518

NA

Analytical Results

06/15/2018 06/27/2018

Sample ID:

Lab ID:

Collected:

Received:

RFD Regulating Sampling Location: Red Fleet Dam1817862001

Method: NIOSH 7300 Mod., Paint Prepared: 06/28/2018 (217723)Sampling Info: Weight 0.0421 grams Analyzed: 06/28/2018 (217763)

Media: Paint Chip Instrument: ICP01

Analyte RL (%)Result (%)

0.03044Lead

06/15/2018 06/27/2018

Sample ID:

Lab ID:

Collected:

Received:

RFD Surge Sampling Location: Red Fleet Dam1817862002

Method: NIOSH 7300 Mod., Paint Prepared: 06/28/2018 (217723)Sampling Info: Weight 0.1077 grams Analyzed: 06/28/2018 (217763)

Media: Paint Chip Instrument: ICP01

Analyte RL (%)Result (%)

0.05846Lead

Comments Sample: 1817862001

The lead result for this sample is reported from 10X dilution data due to a result above the linear range. The reporting limit has been raised by the dilution factor.

Sample: 1817862002

The lead result for this sample is reported from 50X dilution data due to a result above the linear range. The reporting limit has been raised by the dilution factor.

Report Authorization

Method Analyst Peer Review

(/S/ is an electronic signature that complies with 21 CFR Part 11)

/S/ Peter P. Steen /S/ Brandon Dick NIOSH 7300 Mod., Paint

06/28/2018 12:27 06/28/2018 14:58

Laboratory Contact Information

(801) 266-7700 alslt.lab@ALSGlobal.com www.alsslc.com

ALS Environmental 960 W Levoy Drive Salt Lake City, Utah 84123

Phone:

Email:

Web:

Page 1 of 2 Thu, 06/28/18 3:16 PM IHREP-V12.6

ADDRESS 960 West LeVoy Drive, Salt Lake City, Utah, 84123 USA PHONE FAX+1 801 266 7700 +1 801 268 9992

ALS GROUP USA, CORP. An ALS Limited Company

ANALYTICAL REPORT

Project Manager: Rand Potter

Workorder: 34-1817862

Purchase Order:

Client Project ID: Red Fleet Dam 061518

NA

The results provided in this report relate only to the items tested.

Samples were received in acceptable condition unless otherwise noted.

Samples have not been blank corrected unless otherwise noted.

This test report shall not be reproduced, except in full, without written approval of ALS.

General Lab Comments

ALS provides professional analytical services for all samples submitted. ALS is not in a position to interpret the data and assumes no responsibility for the quality of the samples submitted.

All quality control samples processed with the samples in this report yielded acceptable results unless otherwise noted.

ALS is accredited for specific fields of testing (scopes) in the following testing sectors. The quality system implemented at ALS conforms to accreditation requirements and is applied to all analytical testing performed by ALS. The following table lists testing sector, accreditation body, accreditation number and website. Please contact these accrediting bodies or your ALS project manager for the current scope of accreditation that applies to your analytical testing.

Testing Sector Accreditation Body Certificate Number

Website

Environmental PJLA (DoD ELAP)

Utah (TNI) Nevada Oklahoma Iowa Florida (TNI)

L17-288

DATA1

UT00009

UT00009

IA# 376

E871067 http://www.pjlabs.com http://health.utah.gov/lab/labimp/ http://ndep.nv.gov/bsdw/labservice.htm http://www.deq.state.ok.us/CSDnew/ http://www.iowadnr.gov/InsideDNR/RegulatoryWater.aspx http://www.dep.state.fl.us/labs/bars/sas/qa/

Industrial Hygiene 101574 http://www.aihaaccreditedlabs.orgAIHA (ISO 17025 & AIHA

IHLAP/ELLAP)

Lead Testing:

CPSC PJLA (ISO 17025) L17-291 http://www.pjlabs.com Soil, Dust, Paint AIHA (ISO 17025, AIHA

ELLAP and NLLAP) 101574 http://www.aihaaccreditedlabs.org

Dietary Supplements PJLA (ISO 17025) L17-291 http://www.pjlabs.com

Texas (TNI) T104704456-11-1 http://www.tceq.texas.gov/field/qa/lab_accred_certif.html

(Standard) http://www.pjlabs.comL17-291PJLA (ISO 17025)

Definitions LOD = Limit of Detection = MDL = Method Detection Limit, A statistical estimate of method/media/instrument sensitivity.

LOQ = Limit of Quantitation = RL = Reporting Limit, A verified value of method/media/instrument sensitivity.

ND = Not Detected, Testing result not detected above the LOD or LOQ.

NA = Not Applicable.

** No result could be reported, see sample comments for details.

< This testing result is less than the numerical value.

( ) This testing result is between the LOD and LOQ and has higher analytical uncertainty than values at or above the LOQ.

Page 2 of 2 Thu, 06/28/18 3:16 PM IHREP-V12.6