B08_Attachment_10_140P8422R0005_CS4_HazmatTestResults_0003.pdf
PDF 606 KB Posted
- Attached to
- Replace Failed Septic Tank & Systems, NPS-PINN
- Solicitation number
- 140P8422R0005
About this file
This document includes a federal contract solicitation and related opportunity notice. The National Park Service at Pinnacles National Park requires a contractor to demolish and abandon existing wastewater facilities and construct new wastewater infrastructure at the East Side Campground located approximately 25 miles south of Tres Pino, California. The contractor must provide all labor, equipment, testing, and supplies to complete the work per the project specifications and drawings. The work must be performed in accordance with local, state, and federal laws and the contractor must obtain necessary permits. The project value is estimated between $1,000,000 to $5,000,000. The NAICS code is 237110 with a $39.5 million size standard. The government will award a firm-fixed price contract to a service-disabled veteran-owned small business. The full solicitation is available on SAM and includes a site visit scheduled for June 29, 2022. Interested parties should direct any questions to the contracting officer by the specified date.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Approved by:
Technical Manager Andrew Ikeda
Report for:
Ms. Karin Schroeter Terracon Consultants, Inc. - Emeryville 1466 66th Street Emeryville, CA 94608
Regarding: Project: R1207806; Pinnacles National Park, Davido Consulting Group-R.R. Building
EML ID: 2508861
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. Due to the nature of the analyses performed, field blank correction of results is not applied. The results relate only to the samples as received. Sample size, as it relates to Wipe samples only, is supplied by the client.
Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Lead - Flame AA: 10-26-2020
Service SOPs: Lead - Flame AA (EM-BC-S-8443) AIHA-LAP, LLC accredited service, Lab ID #178697
Eurofins EMLab P&K's LabServe® reporting system includes automated fail-safes to ensure that all AIHA-LAP, LLC quality requirements are met and notifications are added to reports when any quality steps remain pending.
EMLab ID: 2508861, Page 1 of 2EMLab P&K, LLC
Eurofins EMLab P&K 17461 Derian Ave, Suite 100, Irvine, CA 92614
(866) 888-6653 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consulting Group-R.R. Building
Date of Sampling: 10-22-2020 Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
LEAD: FLAME ATOMIC ABSORPTION SPECTROMETRY
Location: L-1:
Grey CMU Brick Wall L-2:
Brown Metal Door Frame L-3:
White Wood Walls Comments (see below) None None None
Lab ID-Version‡: 11953581-1 11953582-1 11953583-1
Analysis Date: 10/26/2020 10/26/2020 10/26/2020
Sample type Paint Chip sample Paint Chip sample Paint Chip sample
Method* NIOSH 7082 & EPA 7000B modified
NIOSH 7082 & EPA 7000B
modified
NIOSH 7082 & EPA 7000B
modified
† Method Reporting Limit 40 ppm 39 ppm 39 ppm
Sample size 0.2524 grams 0.2594 grams 0.2571 grams
§Total Lead Result < 40 ppm 40 ppm < 39 ppm
Comments:
EMLab ID: 2508861, Page 2 of 2EMLab P&K, LLC
Sample results have not been corrected for blank values.
Bulk samples are not covered under the AIHA-LAP, LLC service accreditation.
Wipe samples must meet ASTM E1792 criteria. Method Reporting Limits may not be valid for non-ASTM E1792 wipe samples.
*Sample preparation and analytical methods are based upon NIOSH 7082 and EPA 7000B.
† The Method Reporting Limit is the minimum concentration of Lead that the laboratory can confidently detect in the sample.
§ Total Lead Result has been rounded to two significant figures to reflect analytical precision.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
HAZARDOUS MATERIALS TESTING: ASBESTOS
Approved by:
Approved Signatory Renee Luna-Trepczynski
Report for:
Heidi Santos, Ms. Karin Schroeter Terracon Consultants, Inc. - Emeryville 1466 66th Street Emeryville, CA 94608
Regarding: Project: R1207806; Pinnacles National Park, Davido Consultin
EML ID: 2508762
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 10-27-2020
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 500031-0
EMLab ID: 2508762, Page 1 of 7Aerotech Laboratories, Inc.
1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Heidi Santos, Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consultin
Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
ASBESTOS PLM REPORT
Total Samples Submitted: 21 Total Samples Analyzed: 21
Total Samples with Layer Asbestos Content > 1%: 0
Location: 1A, Roofing;Asphalt/Gravel;East Rest Room;S Lab ID-Version‡: 11954503-1
Sample Layers Asbestos Content Black Roofing Tar ND
Pink Fibrous Material ND Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND
Black Asphalt ND Composite Non-Asbestos Content: 10% Glass Fibers
2% Cellulose Sample Composite Homogeneity: Poor
Location: 1B, Roofing;Asphalt/Gravel;East Rest Room;E Lab ID-Version‡: 11954504-1
Sample Layers Asbestos Content Black Asphalt ND
Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND
Pink Fibrous Material ND Yellow Wood ND
Composite Non-Asbestos Content: 10% Cellulose 10% Glass Fibers
Sample Composite Homogeneity: Poor
EMLab ID: 2508762, Page 2 of 7Aerotech Laboratories, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Heidi Santos, Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consultin
Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
ASBESTOS PLM REPORT
Location: 1C, Roofing;Asphalt/Gravel;East Rest Room;N Lab ID-Version‡: 11954505-1
Sample Layers Asbestos Content Black Asphalt ND
Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND Black Roofing Tar and Felt ND
Pink Fibrous Material ND Composite Non-Asbestos Content: 10% Glass Fibers
2% Cellulose Sample Composite Homogeneity: Poor
Location: 2A, Pipe Pent Mastic;Grey;East Rest Room;S Lab ID-Version‡: 11954506-1
Sample Layers Asbestos Content Black Mastic ND
Black Felt ND Composite Non-Asbestos Content: 5% Cellulose
2% Glass Fibers Sample Composite Homogeneity: Moderate
Location: 2B, Pipe Pent Mastic;Grey;East Rest Room;E Lab ID-Version‡: 11954507-1
Sample Layers Asbestos Content Black Mastic ND
Composite Non-Asbestos Content: 8% Cellulose Sample Composite Homogeneity: Good
EMLab ID: 2508762, Page 3 of 7Aerotech Laboratories, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Heidi Santos, Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consultin
Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
ASBESTOS PLM REPORT
Location: 2C, Pipe Pent Mastic;Grey;East Rest Room;N Lab ID-Version‡: 11954508-1
Sample Layers Asbestos Content Black Mastic ND
Composite Non-Asbestos Content: 8% Cellulose Sample Composite Homogeneity: Good
Location: 3A, Concrete;East Rest Room;Men's Floor Lab ID-Version‡: 11954509-1
Sample Layers Asbestos Content Gray Concrete ND
Sample Composite Homogeneity: Poor
Location: 3B, Concrete;East Rest Room;Women's Floor Lab ID-Version‡: 11954510-1
Sample Layers Asbestos Content Gray Concrete ND
Sample Composite Homogeneity: Poor
Location: 3C, Concrete;East Rest Room;Men's Porch Lab ID-Version‡: 11954511-1
Sample Layers Asbestos Content Gray Concrete ND
Sample Composite Homogeneity: Poor
EMLab ID: 2508762, Page 4 of 7Aerotech Laboratories, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Heidi Santos, Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consultin
Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
ASBESTOS PLM REPORT
Location: 4A, Sealant;Grey;East Rest Room;W Lab ID-Version‡: 11954512-1
Sample Layers Asbestos Content Tan Sealant with Multilayered Paint ND
Sample Composite Homogeneity: Good
Location: 4B, Sealant;Grey;East Rest Room;E Lab ID-Version‡: 11954513-1
Sample Layers Asbestos Content Tan Sealant with Multilayered Paint ND
Sample Composite Homogeneity: Good
Location: 4C, Sealant;Grey;East Rest Room;S Lab ID-Version‡: 11954514-1
Sample Layers Asbestos Content Tan Sealant with Multilayered Paint ND
Sample Composite Homogeneity: Good
Location: 5A, Brown Paint On Door With A Coating;East Restroom;S;Men Lab ID-Version‡: 11954515-1
Sample Layers Asbestos Content Brown Paint ND Tan Coating ND
Sample Composite Homogeneity: Moderate
EMLab ID: 2508762, Page 5 of 7Aerotech Laboratories, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Heidi Santos, Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consultin
Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
ASBESTOS PLM REPORT
Location: 5B, Brown Paint On Door With A Coating;East Restroom;S;Men Lab ID-Version‡: 11954516-1
Sample Layers Asbestos Content Brown Paint ND Tan Coating ND
Sample Composite Homogeneity: Moderate
Location: 5C, Brown Paint On Door With A Coating;East Restroom;N;Women Lab ID-Version‡: 11954517-1
Sample Layers Asbestos Content Brown Paint ND Tan Coating ND
Sample Composite Homogeneity: Moderate
Location: 6A, CMU;Brick;/Grout;East Restroom;W Lab ID-Version‡: 11954518-1
Sample Layers Asbestos Content Cream Brick ND Cream Grout ND
Sample Composite Homogeneity: Moderate
Location: 6B, CMU;Brick;/Grout;East Restroom;N Lab ID-Version‡: 11954519-1
Sample Layers Asbestos Content Cream Brick ND Cream Grout ND
Sample Composite Homogeneity: Moderate
EMLab ID: 2508762, Page 6 of 7Aerotech Laboratories, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 Fax (623) 780-7695 www.emlab.comClient: Terracon Consultants, Inc. - Emeryville C/O: Heidi Santos, Ms. Karin Schroeter Re: R1207806; Pinnacles National Park, Davido Consultin
Date of Receipt: 10-23-2020 Date of Report: 10-27-2020
ASBESTOS PLM REPORT
Location: 6C, CMU;Brick;/Grout;East Restroom;E Lab ID-Version‡: 11954520-1
Sample Layers Asbestos Content Cream Brick ND Cream Grout ND
Sample Composite Homogeneity: Moderate
Location: 7A, Paint;White Int;East Restroom;N;Men's Lab ID-Version‡: 11954521-1
Sample Layers Asbestos Content White Paint ND
Sample Composite Homogeneity: Good
Location: 7B, Paint;White Int;East Restroom;S;Men's Lab ID-Version‡: 11954522-1
Sample Layers Asbestos Content White Paint ND
Sample Composite Homogeneity: Good
Location: 7C, Paint;White Int;East Restroom;S;Women's Lab ID-Version‡: 11954523-1
Sample Layers Asbestos Content White Paint ND
Sample Composite Homogeneity: Good
EMLab ID: 2508762, Page 7 of 7Aerotech Laboratories, Inc.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. Eurofins EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
File details come from the government source that posted it. Updated .