B08_Attachment_2_140P8422R0005_Plans.pdf
PDF 23 MB Posted
- Attached to
- Replace Failed Septic Tank & Systems, NPS-PINN Federal contract opportunity
- Solicitation number
- 140P8422R0005
About this file
This document outlines a federal solicitation for replacing failed septic tank and drainage systems at Pinnacles National Park in California. The National Park Service is seeking a contractor to demolish and abandon existing wastewater facilities and construct new ones within the East Side Campground located approximately 25 miles south of Tres Pino. The contractor must provide all labor, equipment, testing, and supplies to complete the work as specified in the solicitation attachments between May 1st and October 31st. The project cost is estimated between $1,000,000 to $5,000,000. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. A site visit is scheduled for June 29th and questions must be submitted to the contracting officer by the specified date.
View the file
Other files for this federal contract opportunity
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL ABBREVIATIONS
NOTE: THIS IS A SUPPLEMENTAL STANDARD LEGEND. SOME SYMBOLS OR
ABBREVIATIONS MAY APPEAR ON THIS LEGEND AND NOT ON THE PLANS
CONDUIT EXPOSED
CONDUIT CONCEALED or BURIED
TICK MARKS W/BARS INDICATES NUMBER OF #10 CONDUCTORS WITH #10 GROUND
HOME RUN-DESTINATION SHOWN
CONDUIT DOWN
CONDUIT UP
CONNECTION POINT (CONTRACTOR SHALL DETERMINE CONNECTION CONFIGURATION)
MAJOR ELECTRICAL COMPONENT OR DEVICE NAME OR
IDENTIFYING SYMBOL AS SHOWN
EXOTHERMIC WELD, TERMINATION OR SPLICE POINT
GROUND ROD
CIRCUIT BREAKER
CURRENT TRANSFORMER, NUMBER INDICATED
ELECTRICAL SYMBOLS
LA-2
MCC
TICK MARKS WITHOUT BARS INDICATES NUMBER OF #12 CONDUCTORS WITH #12 GROUND
DUPLEX RECEPTACLE
QUADRUPLEX RECEPTACLE
SURFACE MOUNT PANELBOARD
D E V
IC
E B
O X
E S
SH
A
LL
B
E
C O
D U
N
LE
S S
O
TH
E R
W
IS
E
N O
TE
D
KEYNOTE1
A - AMMETER, AMPERE
AC - ALTERNATING CURRENT
AFF - ABOVE FINISHED FLOOR OR GRADE
AIC - AMPS INTERRUPTING CAPACITY
ATS - AUTOMATIC TRANSFER SWITCH
BGES - BUILDING GROUND ELECTRODE SYSTEM
BRKR - BREAKER
BOD - BOTTOM OF DEVICE
C or COND - CONDUIT
CAB - CABINET
CEC - CALIFORNIA ELECTRIC CODE
CKT - CIRCUIT
COD - CENTER OF DEVICE
CT - CURRENT TRANSFORMER
DC - DIRECT CURRENT
(E) or EXIST - EXISTING
EEOR - ELECTRICAL ENGINEER OF RECORD
EGC - EQUIPMENT GROUNDING CONDUCTOR
ENC - ENCLOSURE
(F) - FUTURE
G - EQUIPMENT GROUNDING CONDUCTOR
GEC - GROUNDING ELECTRODE CONDUCTOR
GFCI - GROUND FAULT CIRCUIT INTERRUPT
MBJ - MAIN BONDING JUMPER
MCB - MAIN CIRCUIT BREAKER
MFR - MANUFACTURER
MLO - MAIN LUG ONLY
MOCP - MAXIMUM OVERCURRENT PROTECTION
MSB - MAIN SWITCH BOARD
NEC - NATIONAL ELECTRIC CODE
NEMA - NATIONAL ELECTRIC MANUFACTURER'S ASSOCIATION
N - NEUTRAL
(N) - NEW
OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI - OWNER FURNISHED, OWNER INSTALLED
PB - PULLBOX
PNL - PANELBOARD
RCPT - RECEPTACLE
SWBD - SWITCHBOARD
SBJ - SYSTEM BONDING JUMPER
SSBJ - SUPPLY SIDE BONDING JUMPER
TOD - TOP OF DEVICE
TR - TAMPER
TYP - TYPICAL
V - VOLTMETER, VOLT
W - WATT
WW - WIREWAY
WP - WEATHERPROOF (NEMA 3R)
XFMR - TRANSFORMER
NOTE: THIS IS A SUPPLEMENTAL STANDARD ELECTRICAL LEGEND. SOME SYMBOLS MAY APPEAR ON THIS LEGEND AND NOT ON THE
PLANS. SEE LIGHTING CONTROL SHEET FOR LIGHTING LEGEND.
LI
N
E T
Y P
E S
A N
D S
Y M
B O
LS
E Q
U
IP
M E N
T A
N N
O
TA
TI
O
N
(A : B) INDICATES INTERCONNECTION OF PATHWAYS AND/OR CONDUCTORS, E.G., 4"C-4#500,1#3G (MSB : PNL A) INDICATES CONDUIT AND CONDUCTORS ROUTED FROM THE MAIN SWITCHBOARD TO PANELBOARD A.
INDICATES FIRE RATED WALL
SINGLE OR THREE PHASE RECEPTACLE, SEE PLAN SHEETS TYPE PER LOCATION
GROUNDING ELECTRODE
D E V
IC
E S
400A, 120/240V, 1Ø, 3W
M (E) UTILITY
METER
(#1010614514)
(E) 400A
2P
(E) UTILITY XFMR
(E) CUSTOMER
METER
(E) SWBD A
M
(N) 50A
2P
(N)
PNL
C2
(N) 50A
2P
(N)
PNL
C3
(E) PANEL A
200A, 120/240V, 1Ø, 3W
M (E) UTILITY
METER
(#1009305059)(E)
200A 2P
(E)
UTILITY XFMR
(N) 50A
2P
(N)
PNL
C1
(E) (2)
30A 1P
(2) (E) 100A
2P
(E) 20A
1P
(2) (E) 40A
2P
(E) 30A
2P
(15) (E)
SPACES
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 30A
1P
(E) 20A
1P
(E) 20A
1P (E)
SPACES
(23)
(E)
COMF.
STATION
#2
(E)
AMPHI-
THEATER
(N
/2 "C
-3
,1
G
1 1
(N
"C
-3
/0
,1
G
(N
"C
-3
,1
G
(N) PANEL B
(NEMA 3R)
100A, 120/240V, 1Ø, 3W, 10kAIC
M UTILITY
METER
50A 2P
(N)
UTILITY XFMR
GND TERMINAL BAR
MBJ AT MSB
(N)
PNL
C5
(N
"C
-3
/0
,1
G
E4 (N) 3/4"C-1#8 BARE CU CONDUCTOR
2 (N) (2) 4"C-EMPTY
(NEMA 3R) ,TYP.
(E) 200A
1P
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(E)
LOAD
(N) 3/4"C-1#4 BARE CU CONDUCTOR
6'-0" MIN.
TYP.,
(N) 3/4"C-1#4 BARE CU
CONDUCTOR
(N) 3/4"C-1#4 BARE CU CONDUCTOR
GND BUS GND BUS
GND BUS GND BUS
R
EG
IS
TE
RE
D
PROFESSIONAL
ENG
IN
EE
R
ST AT E O F C A L I F O R N IA
No. E22549
EL ECT R I CAL
B R Y A
N
SE
NRABM I C H A LE
PACE
ENGINEERING
REDDING, CALIFORNIA
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
SHEET
PMIS/PKG NO.
DRAWING NO.
OF
TITLE OF SHEET
148519
DCG, INC.
SEATTLE, WA
253759
PINNACLES NATIONAL PARK
C L o c a l R e v it F ile s \2
.0
E
P in n a c le s N a ti o n a l P a rk
L k c .r v t
/1
/2
:2
:1
P
M
ONE-LINE DIAGRAM
E0 02/16/22
KC
BB
BB
2423-2499, PINNACLES HWY, PAICINES, CA 95043
EAST SIDE CAMPGROUND
1. PROVIDE AND INSTALL NEW BREAKER IN EXISTING SPACE SHOWN OF THE SAME TYPE AND
RATING AS EXISTING. UPDATE CIRCUIT DIRECTORY.
2. PROVIDE AND INSTALL IN ACCORDANCE WITH UTILITY REQUIREMENTS.
KEYNOTES
NOTE#
E0
1ONE-LINE DIAGRAM
LINE-LINE (1Ø) I = CURRENT Vd = VOLTAGE DROP
LINE-NEUTRAL LINE-LINE (3Ø) L = DISTANCE R = IMPEDENCE
2.92%
PUMP - FURTHEST LOAD LINE-NEUTRAL PVC CU 1 12 7 26 120 1.70 0.29 0.24%
PNL B - PNL C5 LINE-LINE (1Ø) PVC CU 1 2/0 40 730 240 0.11 6.42 2.68%
DISTRIBUTION LOAD TYPE
CONDUIT
MATERIAL
CONDUCTOR
MATERIAL
QUANTITY OF
RUNS
CONDUCTOR
SIZE (AWG)
CURRENT
(A)
DISTANCE
(FT)
VOLTAGE (V) Impedence (Z)
VOLTAGE
DROP (Vd)
VOLTAGE
DROP (%)
VOLTAGE DROP CALCULATIONS
ELECTRICAL SERVICE - 1Ø 3,732 VA / 240 V = 16 A
NON-CONTINUOUS LOADS TOTAL 3,732 VA
LARGEST MOTOR LOADS - 220.18(a) 1,488 VA * 25% = 372 VA
SPECIAL LOADS - 220.14(a), 220.56, 422.10(a) = 3,360 VA
NON-CONTINUOUS LOADS
COMMERCIAL LOAD CALCULATIONS (PNL B)
TOTAL LOAD 3360
CONTROL PANEL 120 3 1 1 360
EFFLUENT PUMP #5 240 13 1 1 3000
LOAD VAC A Ø QTY TOTAL VA
NON-CONTINUOUS SPECIAL LOADS (PNL B)
ELECTRICAL SERVICE - 1Ø 38,628 VA / 240 V = 161 A
EXISTING MAXIMUM DEMAND = 21,000 VA
EXISTING LOADS
NON-CONTINUOUS LOADS TOTAL 17,628 VA
LARGEST MOTOR LOADS - 220.18(a) 1,488 VA * 25% = 372 VA
SPECIAL LOADS - 220.14(a), 220.56, 422.10(a) = 17,256 VA
NON-CONTINUOUS LOADS
COMMERCIAL LOAD CALCULATIONS (PNL A)
TOTAL LOAD 17256
CONTROL PANEL 120 3 1 1 360
EFFLUENT PUMP #1 240 6 1 1 1536
(E) EVC 240 32 1 2 15360
LOAD VAC A Ø QTY TOTAL VA
NON-CONTINUOUS SPECIAL LOADS (PNL A)
ELECTRICAL SERVICE - 1Ø 44,580 VA / 240 V = 186 A
EXISTING MAXIMUM DEMAND = 42,000 VA
EXISTING LOADS
NON-CONTINUOUS LOADS TOTAL 2,580 VA
LARGEST MOTOR LOADS - 220.18(a) 1,488 VA * 25% = 372 VA
SPECIAL LOADS - 220.14(a), 220.56, 422.10(a) = 2,208 VA
NON-CONTINUOUS LOADS
COMMERCIAL LOAD CALCULATIONS (SWBD A)
TOTAL LOAD 2208
CONTROL PANEL 120 3 1 2 720
EFFLUENT PUMP #3 240 6 1 1 1488
EFFLUENT PUMP #2 240 6 1 1 1536
LOAD VAC A Ø QTY TOTAL VA
NON-CONTINUOUS SPECIAL LOADS (SWBD A)
R
EG
IS
TE
RE
D
PROFESSIONAL
ENG
IN
EE
R
ST AT E O F C A L I F O R N IA
No. E22549
EL ECT R I CAL
B R Y A
N
SE
NRABM I C H A LE
PACE
ENGINEERING
REDDING, CALIFORNIA
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
SHEET
PMIS/PKG NO.
DRAWING NO.
OF
TITLE OF SHEET
148519
DCG, INC.
SEATTLE, WA
253759
PINNACLES NATIONAL PARK
C L o c a l R e v it F ile s \2
.0
E
P in n a c le s N a ti o n a l P a rk
L k c .r v t
/1
/2
:2
:1
P
M
PANEL SCHEDULES
E1 02/16/22
KC
BB
BB
2423-2499, PINNACLES HWY, PAICINES, CA 95043
EAST SIDE CAMPGROUND
TOTAL LOAD (AMPS) 10 7
TOTAL LOAD (VA) 1104 VA 744 VA
PHASE A PHASE B Notes:
17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18
15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16
13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14
11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12
9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10
7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8
5 3/4"C-2#12,1#12G CONTROL PANEL #1 20 A -- 360 VA 0 VA -- 20 A SPARE 6
3 744 VA 0 VA -- 20 A SPARE 4
3/4"C-2#12,1#12G EFFLUENT PUMP #1 20 A --
744 VA 0 VA -- 20 A SPARE 2
CKT HOME RUN LOAD NAME TRIP
INT
TYPE
A B A B
INT
TYPE
TRIP LOAD NAME HOME RUN CKT
(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)
ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A
MOUNTING SURFACE WIRES 3 BUS RATING 100 A
LOCATION COMFORT STATION #1,5 LIFT STATION VOLTS 120/240 SINGLE AIC RATING 10,000
(N) BRANCH PANEL C1
TOTAL LOAD (AMPS) 10 7
TOTAL LOAD (VA) 1128 VA 768 VA
PHASE A PHASE B Notes:
17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18
15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16
13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14
11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12
9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10
7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8
5 3/4"C-2#12,1#12G CONTROL PANEL #2 20 A -- 360 VA 0 VA -- 20 A SPARE 6
3 768 VA 0 VA -- 20 A SPARE 4
3/4"C-2#12,1#12G EFFLUENT PUMP #2 20 A --
768 VA 0 VA -- 20 A SPARE 2
CKT HOME RUN LOAD NAME TRIP
INT
TYPE
A B A B
INT
TYPE
TRIP LOAD NAME HOME RUN CKT
(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)
ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A
MOUNTING SURFACE WIRES 3 BUS RATING 100 A
LOCATION COMFORT STATION #2 VOLTS 120/240 SINGLE AIC RATING 10,000
(N) BRANCH PANEL C2
TOTAL LOAD (AMPS) 10 7
TOTAL LOAD (VA) 1104 VA 744 VA
PHASE A PHASE B Notes:
17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18
15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16
13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14
11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12
9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10
7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8
5 3/4"C-2#12,1#12G CONTROL PANEL #3 20 A -- 360 VA 0 VA -- 20 A SPARE 6
3 744 VA 0 VA -- 20 A SPARE 4
3/4"C-2#12,1#12G EFFLUENT PUMP #3 20 A --
744 VA 0 VA -- 20 A SPARE 2
CKT HOME RUN LOAD NAME TRIP
INT
TYPE
A B A B
INT
TYPE
TRIP LOAD NAME HOME RUN CKT
(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)
ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A
MOUNTING SURFACE WIRES 3 BUS RATING 100 A
LOCATION COMFORT STATION #3 VOLTS 120/240 SINGLE AIC RATING 10,000
(N) BRANCH PANEL C3
TOTAL LOAD (AMPS) 10 7
TOTAL LOAD (VA) 1104 VA 744 VA
PHASE A PHASE B Notes:
17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18
15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16
13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14
11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12
9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10
7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8
5 (N) 3/4"C-2#12,1#12G (N) CONTROL PANEL #5 20 A -- 360 VA 0 VA -- 20 A SPARE 6
3 744 VA 0 VA -- 20 A SPARE 4
(N) 3/4"C-2#12,1#12G (N) EFFLUENT PUMP #5 20 A --
744 VA 0 VA -- 20 A SPARE 2
CKT HOME RUN LOAD NAME TRIP
INT
TYPE
A B A B
INT
TYPE
TRIP LOAD NAME HOME RUN CKT
(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)
ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A
MOUNTING SURFACE WIRES 3 BUS RATING 100 A
LOCATION COMFORT STATION #5 VOLTS 120/240 SINGLE AIC RATING 10,000
(N) BRANCH PANEL C5
1. PROVIDE AND INSTALL NEW BREAKER LOCKABLE IN THE "OFF" POSITION.
KEYNOTES
NOTE#
W V
W V
P
IN
E
1 14" O AK
88" O AK
70" O AK
70" O AK
56" O AK
18" SYCAM O RE
20" SYCAM
OR E
16" TR
EE
24" TR
EE
48" OA
K
3 9-12" TRE
E
60" OA
K
30" PINE
13" PINE
24" O AK
10" OA
K
12" TR
EE
32" O AK
48" OA
K
12" PINE
17" PINE
50" STU
MP
0 14" O
AK
8 5-7" TRE
E
8" OA
K
14" TR
EE
3 14-19
" TRE E
PIPE86.31
PIPE 18 PVC86.33
FL86.23
FL86.29
FL86.19
TEL88.34
TEL88.34
TEL88.35
TEL88.33
TEL88.31
TEL88.30
TEL
88.24
TEL88.26
TEL88.27
TEL88.27
TEL88.28
TEL88.27
TEL88.28
325341
ELEC88.59
88.526BFP
88.529BFP
88.527BFP
88.525BFP
88.162BENCH88.156BENCH
G ATE
G ATE
G ATE
G ATE
SEPTIC
SEPTIC
SE
PTIC
SE
PTIC
SE
PTIC
SE
PTIC
SEPTIC
SEPTIC
SE
PTIC
SE
PTIC
S
S
S
S
S
S
S
S
S
S
FH D
Y
H
W V
W V
W V
O S W
W V
O S W
D
Y
H
W V
D
YH
O S W
O S W
O S W
O S W
O S W
BIN
BIN
BIN
BIN
S O
W
S O
W
S O
W
(E) COMFORT STATION #5
(E) COMFORT STATION #3
(E) COMFORT STATION #2
(E) COMFORT STATION #1
(E) VISITOR CENTER
(E) PG&E POLE W/RISER
(E) PNL A
C A
LI
FO
RN
IA
CAMPGROUND ROAD
C A
M
PG
RO
U N
D R
O A
D
CAM
PGROUND ROAD
(E) SWBD A
(N) PB #4
(N) PB #5
(N) PB #6
(N) PB #8
(N) PB #7
(N) PB #11
(N) PB #10
(N) PB #15
(N) PB #16
(N) PB #14
ENLARGED VIEW
E2
CALIF
O
RNIA
E4
,TYP.
E3
E3
E3
E3
E4
TYP.,
E4
1TYP.,
(N) PB #9
(N) PB #12
(N) PB #13
E4
ENLARGED VIEW
ENLARGED VIEW
ENLARGED VIEW
ENLARGED VIEW
(N) UTILITY RISER
(E) UTILITY POLE W/
(N) UTILITY XFMR
(N) METER PNL B
(N) (2) 4"C-EMPTY (UTILITY XFMR : METER PNL B)
C
ALIF
O
RNIA
E4
TO (N)
PULLBOX #16
(N) 2"C-3#2/0,1#6G (METER PNL B : PNL C5)
(N) GROUND RODS
E4
R
EG
IS
TE
RE
D
PROFESSIONAL
ENG
IN
EE
R
ST AT E O F C A L I F O R N IA
No. E22549
EL ECT R I CAL
B R Y A
N
SE
NRABM I C H A LE
PACE
ENGINEERING
REDDING, CALIFORNIA
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
SHEET
PMIS/PKG NO.
DRAWING NO.
OF
TITLE OF SHEET
148519
DCG, INC.
SEATTLE, WA
253759
PINNACLES NATIONAL PARK
C L o c a l R e v it F ile s \2
.0
E
P in n a c le s N a ti o n a l P a rk
L k c .r v t
/1
/2
:2
:1
P
M
ELECTRICAL SITE PLAN
E2 02/16/22
KC
BB
BB
2423-2499, PINNACLES HWY, PAICINES, CA 95043
EAST SIDE CAMPGROUND
1. PATHWAYS AND RACEWAYS DIRECTLY RELATED TO THE FEEDER CONDUCTORS IN THE
DISTRIBUTION SYSTEM ARE SHOWN ON THE SITE PLAN. REFER TO THE ONE-LINE DIAGRAM
AND ENLARGED PLANS FOR CALLOUTS REGARDING CONDUIT/CONDUCTOR
INFORMATION.
2. TRENCH ADJACENT TO EXISTING CREEK CULVERT. REPAIR SURFACES WHERE NECESSARY TO
MATCH EXISTING CONDITIONS. SEE DETAIL 3, SHEET E4 FOR ADDITIONAL INFORMATION.
3. PROVIDE AND INSTALL CONDUIT SEALING BUSHINGS AT LOCATIONS SHOWN.
4. PROVIDE AND INSTALL IN ACCORDANCE WITH UTILITY REQUIREMENTS.
5. DIRECTIONALLY BORE UNDER HIGHWAY, AND PROVIDE AND INSTALL NEW CONDUIT IN
ACCORDANCE WITH UTILITY REQUIREMENTS.
6. NEW RACEWAY SHALL BE ROUTED ALONGSIDE THE WATER LINE IN THE SAME TRENCH.
MAINTAIN ADEQUATE DISTANCE BETWEEN PIPING SYSTEMS PER ELECTRICAL
SPECIFICATIONS.
7. TRENCH ADJACENT TO EXISTING ROAD. REPAIR SURFACES WHERE NECESSARY TO MATCH
EXISTING CONDITIONS. SEE DETAIL 3, SHEET E4 FOR ADDITIONAL INFORMATION.
KEYNOTES
NOTE
E21" = 100'-0"
1ELECTRICAL SITE PLAN
1. REFER TO SPECIFICATION SECTION 260526, "GROUNDING AND BONDING FOR ELECTRICAL
SYSTEMS" FOR ADDITIONAL GROUNDING AND BONDING REQUIREMENTS AT
UNDERGROUND TRENCHING, PULLBOXES, ABOVE GROUND ENCLOSURES AND OTHER
STRUCTURES.
2. WHERE TRENCHING ACROSS EXISTING ASPHALT, CONCRETE, OR GRAVEL ROADS OR
PATHWAYS, REPAIR SURFACES TO MATCH EXISTING CONDITIONS.
GENERAL NOTES
# NOTE
E21" = 20'-0"
2ENLARGED SITE PLAN
WV
WV
S SEPTIC
S SEPTIC
B I N
D
Y
H
FH
W V
TO EW
88. 65
B I N
87.92
CP PK&W
88.09
88.06
S SEPTIC
S SEPTIC
S O
W
COMFORT
STATION 5
(N) EFFLUENT PUMP #5
(N) 3/4"C-2#12,1#12G
(CONTROL PNL #5 : EFFLUENT PUMP #5)
(N) PNL C5
E4
,TYP.
(N) 2"C-3#2/0,1#6G
(METER PANEL B : PNL C5)
(N) CONTROL PANEL #5
E4
(N) GND ROD
(N) (2) 3/4"C-2#12,1#12G
(CONTROL PNL #5 : PNL C5)
TO
(N) PB #15
(N) PB #14
(E) COMFORT
STATION 1
C A M
PG
RO
UN
D R
O A D
(N) PNL C1
(E) PNL A
(N) EFFLUENT PUMP #1
E4
(N) 2"C-3#3,1#8G (PNL A : PNL C1)
(N) 3/4"C-2#12,1#12G
(CONTROL PNL #1 : EFFLUENT PUMP #1)
(E) VISITOR CENTER
E4
,TYP.
(N) CONTROL
PANEL #1
(N) GND ROD
(N) (2) 3/4"C-2#12,1#12G
(CONTROL PNL #1 : PNL C1)
(N) PB #2
(N) PB #1
(N) PB #2
(E) COMFORT
STATION 2
(N) PNL C2
E4
(N) PB #6
TO (N) PB #7
TO
(N) PB #5
(N) 1 1/2"C-3#4,1#8G (SWBD A : PNL C2)
(N) 2"C-3#2/0,1#6G (SWBD A : PNL C3)
(N) EFFLUENT PUMP #2
(N) 3/4"C-2#12,1#12G
(CONTROL PNL #2 : EFFLUENT PUMP #2)
E4
,TYP.
E4
(N) CONTROL PANEL #2
TYP.,
(N) GND ROD
(N) (2) 3/4"C-2#12,1#12G
(CONTROL PNL #2 : PNL C2)
E4
TYP.,
COMFORT
STATION 3
CAMPGROUND ROAD
(N) PNL C3
(NEMA 3R)
(N) 2"C-3#2/0,1#6G
(PNL C3 : SWBD A)
(N) EFFLUENT PUMP #3
(N) 3/4"C-2#12,1#12G
(CONTROL PNL #3 : EFFLUENT PUMP #3)
E4
E4
,TYP.
(N) CONTROL PANEL #3
(N) GND ROD
(N) (2) 3/4"C-2#12,1#12G
(CONTROL PNL #3 : PNL C3)
(N) PB #13
TO
(N) PB #12
R
EG
IS
TE
RE
D
PROFESSIONAL
ENG
IN
EE
R
ST AT E O F C A L I F O R N IA
No. E22549
EL ECT R I CAL
B R Y A
N
SE
NRABM I C H A LE
PACE
ENGINEERING
REDDING, CALIFORNIA
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
SHEET
PMIS/PKG NO.
DRAWING NO.
OF
TITLE OF SHEET
148519
DCG, INC.
SEATTLE, WA
253759
PINNACLES NATIONAL PARK
C L o c a l R e v it F ile s \2
.0
E
P in n a c le s N a ti o n a l P a rk
L k c .r v t
/1
/2
:2
:2
P
M
ENLARGED POWER PLANS
E3 02/16/22
KC
BB
BB
2423-2499, PINNACLES HWY, PAICINES, CA 95043
EAST SIDE CAMPGROUND
1. PROVIDE AND INSTALL CONDUIT SEALING BUSHINGS AT LOCATION SHOWN.
2. NEW RACEWAY SHALL BE ROUTED ALONGSIDE THE SEWER LINE IN THE SAME TRENCH.
MAINTAIN ADEQUATE DISTANCE BETWEEN PIPING SYSTEMS PER ELECTRICAL
SPECIFICATIONS.
KEYNOTES
NOTE
E31/16" = 1'-0"
4COMFORT STATION 5 POWER PLAN
E31/32" = 1'-0"
1COMFORT STATION 1 POWER PLAN
E31/16" = 1'-0"
2COMFORT STATION 2 POWER PLAN
E31/16" = 1'-0"
3COMFORT STATION 3 POWER PLAN
1. REFER TO SPECIFICATION SECTION 260526, "GROUNDING AND BONDING FOR ELECTRICAL
SYSTEMS" FOR ADDITIONAL GROUNDING AND BONDING REQUIREMENTS AT
UNDERGROUND TRENCHING, PULLBOXES, ABOVE GROUND ENCLOSURES AND OTHER
STRUCTURES.
2. PROVIDE AND INSTALL ALL MATERIALS FOR THE CONTROL PANEL AND PUMP PER THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
3. WHERE TRENCHING ACROSS EXISTING ASPHALT, CONCRETE, OR GRAVEL ROADS OR
PATHWAYS, REPAIR SURFACES TO MATCH EXISTING CONDITIONS.
GENERAL NOTES
# NOTE
FINISH GRADE
D
2"MIN2"MIN
WARNING
TAPE
COMPACTED
TRENCH
BACKFILL
12"
BACKFILL W/ SAND
HAND TAMP
M
IN
M
IN
M
IN
NOTES:
1. D=3" MIN FOR 2" AND LARGER CONDUIT
2. D=2" MIN FOR 1 1/2" AND SMALLER CONDUIT
3. CONDUIT DETAIL FOR LESS THAN 4 RACEWAYS PER TRENCH
EXOTHERMIC WELD CONNECTION,
THERMOWELD, CADWELD, OR EQUAL
#4 BARE CU CONDUCTOR
NOTES:
1. ANCHOR EQUIPMENT TO CONCRETE PAD USING HILTI HY200 EPOXY AND
TORQUE IN ACCORDANCE WITH ESR-3187.
#4@12" MAX
6" CLR, TYP. ALL SIDES
ANCHOR, TYP.
METER
PEDESTAL
CONCRETE PAD
EARTH
FINISHED GRADE
3" , TYP.
WIDTH/DEPTH AS REQUIRED
C
LR
3" , TYP.
OUTDOOR PEDESTAL PAD
C
LR
10"
APPROX. WT.
35 LBS.
GND
BUS
GROUND ROD, MIN. 6'-0" SEPARATION,
SEE DETAIL 5, THIS SHEET
6"
6"
24" MIN
PEA GRAVEL OR 3/4"
MINUS CRUSHED ROCK.
ELECTRICAL PULLBOX
AND EXTENSIONS AS
REQUIRED
UNDERGROUND
DUCT, TYP.
FINISHED GRADE
COVER
A
A
VIEW A-A
PVC SECTION
CONCRETE
FILL
LENGTH AS REQ.
(E) CREEK SECTION
(N) CONDUIT/CONDUCTORS
PVC -GRS COUPLING, TYP.
GRS SECTION
PVC SECTION
CONCRETE FILL
PEA GRAVEL OR
3/4" CRUSHED ROCK
FINISHED GRADE
1'-0" MIN.
M
IN
FRONT SIDE - VIEW A-A
1/4" DIAMETER HILTI KWIK BOLT TZ 304 STAINLESS STEEL
WEDGE ANCHOR WITH MINIMUM 3" EMBEDMENT INTO
STRUCTURE, TYP. 4 (EACH CABINET)
CMU OR CONCRETE STRUCTURE
FASTEN CABINET USING 1/4" GALVANIZED FASTENER
INTO 1/4" STRUT CHANNEL CONE NUT; COORDINATE
FINAL NUMBER, LOCATION AND BOLT
CONFIGURATIONS WITH LISTED MANUFACTURER
MOUNTING HOLE LOCATIONS
FINISHED FLOOR
NOTE:
1. TYPICAL PANELBOARD CABINET MAY VARY IN WIDTH AND LENGTH. THIS DETAIL SHALL ACCOUNT FOR LARGEST AND HEAVIEST PANELBOARD AVAILABLE, BUT FASTENING AND ANCHORAGE SHALL BE USED EQUALLY FOR SMALLER CABINET CONFIGURATIONS.
2. WHERE MANUFACTURER REQUIRES A THIRD FASTENING LOCATION, PROVIDE ADDITIONAL STRUT CHANNEL AND FASTENERS.
MATCH ADDITIONAL STRUT CHANNEL WITH OTHERS SHOWN (THIS DETAIL).
3. MAXIMUM BREAKER HANDLE HEIGHT SHALL BE 78".
12 GA, 13/16" GALVANIZED STRUT CHANNEL,
TYP.; CUT STRUT CHANNEL FOR NO REVEAL
OUTSIDE OF CABINET
1" CONDUIT KNOCKOUT, TYP.
(CONDUIT SHALL MATCH KNOCKOUT SIZE IF
MANUFACTURER VARIES)
CONDUIT RACEWAY BETWEEN PANELBOARD
AND CONTROL PANEL WHERE REQUIRED, TYP.
(SEE PLANS AND SPECIFICATIONS); SIZE AND
NUMBER AS REQUIRED (SEE NOTES, THIS DETAIL)
A
A
PANELBOARD
MAXIMUM
WEIGHT 250 LBS
FEEDER SIZE PER ONE-LINE DIAGRAM
TO
CONTROL
PANEL
CONTROL
PANEL
MAXIMUM
WEIGHT
50 LBS
TO
PANELBOARD TO EQUIPMENT
CONDUIT QUANTITIES
PER PLAN, TYP.
5'-0" MAXIMUM
2" GALVANIZED PIPE CAP, TYP.
1-5/8" X 1 5/8" DEEP GALVANIZED CHANNEL STRUT, 12
GAUGE SLOTTED, B-LINE B225H OR APPROVED EQUAL
2" DIA X 10' SCHEDULE 40 GALVANIZED STEEL PIPE (ASTM A53 GR.B)
CONCRETE
FOOTING
3'-0"
4'-3"
CONDUIT
AS SHOWN
5'-0"
12"
DIA
FINISHED GRADE
1 5/8" x 13/16 GALVANIZED
CHANNEL STRUT SPRING NUT WITH
1/2" x 1" GALVANIZED BOLT, TYP.
(B-LINE B525H OR EQUAL)
2" GALVANIZED PIPE CLAMP, B-LINE
B2400-2 OR APPROVED EQUAL
3'-9"
VERTICAL STRUT ATTACHED
TO HORIZONTAL, TYP.
CONTROL PANEL
R
EG
IS
TE
RE
D
PROFESSIONAL
ENG
IN
EE
R
ST AT E O F C A L I F O R N IA
No. E22549
EL ECT R I CAL
B R Y A
N
SE
NRABM I C H A LE
PACE
ENGINEERING
REDDING, CALIFORNIA
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
SHEET
PMIS/PKG NO.
DRAWING NO.
OF
TITLE OF SHEET
148519
DCG, INC.
SEATTLE, WA
253759
PINNACLES NATIONAL PARK
C L o c a l R e v it F ile s \2
.0
E
P in n a c le s N a ti o n a l P a rk
L k c .r v t
/1
/2
:2
:2
P
M
ELECTRICAL DETAILS
E4 02/16/22
KC
BB
BB
2423-2499, PINNACLES HWY, PAICINES, CA 95043
EAST SIDE CAMPGROUND
NTS E4
2UNDERGROUND CONDUIT
NTS E4
4CABLE TO GROUND ROD
NTS E4
6METER PEDESTAL MOUNTING DETAILS
NTS E4
5PULLBOX - PULL THROUGH
NTS E4
3CONCRETE FILL - PVC TO GRS SECTION
NTS E4
1PANELBOARD SURFACE MOUNTING CMU AND CONCRETE CONSTRUCTION
NTS E4
7OUTDOOR EQUIPMENT MOUNTING ASSEMBLY
R
EG
IS
TE
RE
D
PROFESSIONAL
ENG
IN
EE
R
ST AT E O F C A L I F O R N IA
No. E22549
EL ECT R I CAL
B R Y A
N
SE
NRABM I C H A LE
PACE
ENGINEERING
REDDING, CALIFORNIA
SUB SHEET NO.DESIGNED:
TECH. REVIEW:
DATE:
SHEET
PMIS/PKG NO.
DRAWING NO.
OF
TITLE OF SHEET
148519
DCG, INC.
SEATTLE, WA
253759
PINNACLES NATIONAL PARK
C L o c a l R e v it F ile s \2
.0
E
P in n a c le s N a ti o n a l P a rk
L k c .r v t
/1
/2
:2
:2
P
M
TITLE 24 ELECT. DIST.
COMPLIANCE DOCUMENTS
E5 02/16/22
KC
BB
BB
2423-2499, PINNACLES HWY, PAICINES, CA 95043
EAST SIDE CAMPGROUND
File details come from the government source that posted it. Updated .