B08_Attachment_2_140P8422R0005_Plans.pdf

PDF 23 MB Posted

Attached to
Replace Failed Septic Tank & Systems, NPS-PINN Federal contract opportunity
Solicitation number
140P8422R0005
Issued by
Department of the Interior National Park Service Pacific West Region

About this file

This document outlines a federal solicitation for replacing failed septic tank and drainage systems at Pinnacles National Park in California. The National Park Service is seeking a contractor to demolish and abandon existing wastewater facilities and construct new ones within the East Side Campground located approximately 25 miles south of Tres Pino. The contractor must provide all labor, equipment, testing, and supplies to complete the work as specified in the solicitation attachments between May 1st and October 31st. The project cost is estimated between $1,000,000 to $5,000,000. This acquisition is set aside for Service-Disabled Veteran-Owned Small Businesses. A site visit is scheduled for June 29th and questions must be submitted to the contracting officer by the specified date.

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELECTRICAL ABBREVIATIONS

NOTE: THIS IS A SUPPLEMENTAL STANDARD LEGEND. SOME SYMBOLS OR

ABBREVIATIONS MAY APPEAR ON THIS LEGEND AND NOT ON THE PLANS

CONDUIT EXPOSED

CONDUIT CONCEALED or BURIED

TICK MARKS W/BARS INDICATES NUMBER OF #10 CONDUCTORS WITH #10 GROUND

HOME RUN-DESTINATION SHOWN

CONDUIT DOWN

CONDUIT UP

CONNECTION POINT (CONTRACTOR SHALL DETERMINE CONNECTION CONFIGURATION)

MAJOR ELECTRICAL COMPONENT OR DEVICE NAME OR

IDENTIFYING SYMBOL AS SHOWN

EXOTHERMIC WELD, TERMINATION OR SPLICE POINT

GROUND ROD

CIRCUIT BREAKER

CURRENT TRANSFORMER, NUMBER INDICATED

ELECTRICAL SYMBOLS

LA-2

MCC

TICK MARKS WITHOUT BARS INDICATES NUMBER OF #12 CONDUCTORS WITH #12 GROUND

DUPLEX RECEPTACLE

QUADRUPLEX RECEPTACLE

SURFACE MOUNT PANELBOARD

D E V

IC

E B

O X

E S

SH

A

LL

B

E

C O

D U

N

LE

S S

O

TH

E R

W

IS

E

N O

TE

D

KEYNOTE1

A - AMMETER, AMPERE

AC - ALTERNATING CURRENT

AFF - ABOVE FINISHED FLOOR OR GRADE

AIC - AMPS INTERRUPTING CAPACITY

ATS - AUTOMATIC TRANSFER SWITCH

BGES - BUILDING GROUND ELECTRODE SYSTEM

BRKR - BREAKER

BOD - BOTTOM OF DEVICE

C or COND - CONDUIT

CAB - CABINET

CEC - CALIFORNIA ELECTRIC CODE

CKT - CIRCUIT

COD - CENTER OF DEVICE

CT - CURRENT TRANSFORMER

DC - DIRECT CURRENT

(E) or EXIST - EXISTING

EEOR - ELECTRICAL ENGINEER OF RECORD

EGC - EQUIPMENT GROUNDING CONDUCTOR

ENC - ENCLOSURE

(F) - FUTURE

G - EQUIPMENT GROUNDING CONDUCTOR

GEC - GROUNDING ELECTRODE CONDUCTOR

GFCI - GROUND FAULT CIRCUIT INTERRUPT

MBJ - MAIN BONDING JUMPER

MCB - MAIN CIRCUIT BREAKER

MFR - MANUFACTURER

MLO - MAIN LUG ONLY

MOCP - MAXIMUM OVERCURRENT PROTECTION

MSB - MAIN SWITCH BOARD

NEC - NATIONAL ELECTRIC CODE

NEMA - NATIONAL ELECTRIC MANUFACTURER'S ASSOCIATION

N - NEUTRAL

(N) - NEW

OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI - OWNER FURNISHED, OWNER INSTALLED

PB - PULLBOX

PNL - PANELBOARD

RCPT - RECEPTACLE

SWBD - SWITCHBOARD

SBJ - SYSTEM BONDING JUMPER

SSBJ - SUPPLY SIDE BONDING JUMPER

TOD - TOP OF DEVICE

TR - TAMPER

TYP - TYPICAL

V - VOLTMETER, VOLT

W - WATT

WW - WIREWAY

WP - WEATHERPROOF (NEMA 3R)

XFMR - TRANSFORMER

NOTE: THIS IS A SUPPLEMENTAL STANDARD ELECTRICAL LEGEND. SOME SYMBOLS MAY APPEAR ON THIS LEGEND AND NOT ON THE

PLANS. SEE LIGHTING CONTROL SHEET FOR LIGHTING LEGEND.

LI

N

E T

Y P

E S

A N

D S

Y M

B O

LS

E Q

U

IP

M E N

T A

N N

O

TA

TI

O

N

(A : B) INDICATES INTERCONNECTION OF PATHWAYS AND/OR CONDUCTORS, E.G., 4"C-4#500,1#3G (MSB : PNL A) INDICATES CONDUIT AND CONDUCTORS ROUTED FROM THE MAIN SWITCHBOARD TO PANELBOARD A.

INDICATES FIRE RATED WALL

SINGLE OR THREE PHASE RECEPTACLE, SEE PLAN SHEETS TYPE PER LOCATION

GROUNDING ELECTRODE

D E V

IC

E S

400A, 120/240V, 1Ø, 3W

M (E) UTILITY

METER

(#1010614514)

(E) 400A

2P

(E) UTILITY XFMR

(E) CUSTOMER

METER

(E) SWBD A

M

(N) 50A

2P

(N)

PNL

C2

(N) 50A

2P

(N)

PNL

C3

(E) PANEL A

200A, 120/240V, 1Ø, 3W

M (E) UTILITY

METER

(#1009305059)(E)

200A 2P

(E)

UTILITY XFMR

(N) 50A

2P

(N)

PNL

C1

(E) (2)

30A 1P

(2) (E) 100A

2P

(E) 20A

1P

(2) (E) 40A

2P

(E) 30A

2P

(15) (E)

SPACES

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 30A

1P

(E) 20A

1P

(E) 20A

1P (E)

SPACES

(23)

(E)

COMF.

STATION

#2

(E)

AMPHI-

THEATER

(N

/2 "C

-3

,1

G

1 1

(N

"C

-3

/0

,1

G

(N

"C

-3

,1

G

(N) PANEL B

(NEMA 3R)

100A, 120/240V, 1Ø, 3W, 10kAIC

M UTILITY

METER

50A 2P

(N)

UTILITY XFMR

GND TERMINAL BAR

MBJ AT MSB

(N)

PNL

C5

(N

"C

-3

/0

,1

G

E4 (N) 3/4"C-1#8 BARE CU CONDUCTOR

2 (N) (2) 4"C-EMPTY

(NEMA 3R) ,TYP.

(E) 200A

1P

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(E)

LOAD

(N) 3/4"C-1#4 BARE CU CONDUCTOR

6'-0" MIN.

TYP.,

(N) 3/4"C-1#4 BARE CU

CONDUCTOR

(N) 3/4"C-1#4 BARE CU CONDUCTOR

GND BUS GND BUS

GND BUS GND BUS

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EE

R

ST AT E O F C A L I F O R N IA

No. E22549

EL ECT R I CAL

B R Y A

N

SE

NRABM I C H A LE

PACE

ENGINEERING

REDDING, CALIFORNIA

SUB SHEET NO.DESIGNED:

TECH. REVIEW:

DATE:

SHEET

PMIS/PKG NO.

DRAWING NO.

OF

TITLE OF SHEET

148519

DCG, INC.

SEATTLE, WA

253759

PINNACLES NATIONAL PARK

C L o c a l R e v it F ile s \2

.0

E

P in n a c le s N a ti o n a l P a rk

L k c .r v t

/1

/2

:2

:1

P

M

ONE-LINE DIAGRAM

E0 02/16/22

KC

BB

BB

2423-2499, PINNACLES HWY, PAICINES, CA 95043

EAST SIDE CAMPGROUND

1. PROVIDE AND INSTALL NEW BREAKER IN EXISTING SPACE SHOWN OF THE SAME TYPE AND

RATING AS EXISTING. UPDATE CIRCUIT DIRECTORY.

2. PROVIDE AND INSTALL IN ACCORDANCE WITH UTILITY REQUIREMENTS.

KEYNOTES

NOTE#

E0

1ONE-LINE DIAGRAM

LINE-LINE (1Ø) I = CURRENT Vd = VOLTAGE DROP

LINE-NEUTRAL LINE-LINE (3Ø) L = DISTANCE R = IMPEDENCE

2.92%

PUMP - FURTHEST LOAD LINE-NEUTRAL PVC CU 1 12 7 26 120 1.70 0.29 0.24%

PNL B - PNL C5 LINE-LINE (1Ø) PVC CU 1 2/0 40 730 240 0.11 6.42 2.68%

DISTRIBUTION LOAD TYPE

CONDUIT

MATERIAL

CONDUCTOR

MATERIAL

QUANTITY OF

RUNS

CONDUCTOR

SIZE (AWG)

CURRENT

(A)

DISTANCE

(FT)

VOLTAGE (V) Impedence (Z)

VOLTAGE

DROP (Vd)

VOLTAGE

DROP (%)

VOLTAGE DROP CALCULATIONS

ELECTRICAL SERVICE - 1Ø 3,732 VA / 240 V = 16 A

NON-CONTINUOUS LOADS TOTAL 3,732 VA

LARGEST MOTOR LOADS - 220.18(a) 1,488 VA * 25% = 372 VA

SPECIAL LOADS - 220.14(a), 220.56, 422.10(a) = 3,360 VA

NON-CONTINUOUS LOADS

COMMERCIAL LOAD CALCULATIONS (PNL B)

TOTAL LOAD 3360

CONTROL PANEL 120 3 1 1 360

EFFLUENT PUMP #5 240 13 1 1 3000

LOAD VAC A Ø QTY TOTAL VA

NON-CONTINUOUS SPECIAL LOADS (PNL B)

ELECTRICAL SERVICE - 1Ø 38,628 VA / 240 V = 161 A

EXISTING MAXIMUM DEMAND = 21,000 VA

EXISTING LOADS

NON-CONTINUOUS LOADS TOTAL 17,628 VA

LARGEST MOTOR LOADS - 220.18(a) 1,488 VA * 25% = 372 VA

SPECIAL LOADS - 220.14(a), 220.56, 422.10(a) = 17,256 VA

NON-CONTINUOUS LOADS

COMMERCIAL LOAD CALCULATIONS (PNL A)

TOTAL LOAD 17256

CONTROL PANEL 120 3 1 1 360

EFFLUENT PUMP #1 240 6 1 1 1536

(E) EVC 240 32 1 2 15360

LOAD VAC A Ø QTY TOTAL VA

NON-CONTINUOUS SPECIAL LOADS (PNL A)

ELECTRICAL SERVICE - 1Ø 44,580 VA / 240 V = 186 A

EXISTING MAXIMUM DEMAND = 42,000 VA

EXISTING LOADS

NON-CONTINUOUS LOADS TOTAL 2,580 VA

LARGEST MOTOR LOADS - 220.18(a) 1,488 VA * 25% = 372 VA

SPECIAL LOADS - 220.14(a), 220.56, 422.10(a) = 2,208 VA

NON-CONTINUOUS LOADS

COMMERCIAL LOAD CALCULATIONS (SWBD A)

TOTAL LOAD 2208

CONTROL PANEL 120 3 1 2 720

EFFLUENT PUMP #3 240 6 1 1 1488

EFFLUENT PUMP #2 240 6 1 1 1536

LOAD VAC A Ø QTY TOTAL VA

NON-CONTINUOUS SPECIAL LOADS (SWBD A)

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EE

R

ST AT E O F C A L I F O R N IA

No. E22549

EL ECT R I CAL

B R Y A

N

SE

NRABM I C H A LE

PACE

ENGINEERING

REDDING, CALIFORNIA

SUB SHEET NO.DESIGNED:

TECH. REVIEW:

DATE:

SHEET

PMIS/PKG NO.

DRAWING NO.

OF

TITLE OF SHEET

148519

DCG, INC.

SEATTLE, WA

253759

PINNACLES NATIONAL PARK

C L o c a l R e v it F ile s \2

.0

E

P in n a c le s N a ti o n a l P a rk

L k c .r v t

/1

/2

:2

:1

P

M

PANEL SCHEDULES

E1 02/16/22

KC

BB

BB

2423-2499, PINNACLES HWY, PAICINES, CA 95043

EAST SIDE CAMPGROUND

TOTAL LOAD (AMPS) 10 7

TOTAL LOAD (VA) 1104 VA 744 VA

PHASE A PHASE B Notes:

17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18

15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16

13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14

11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12

9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10

7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8

5 3/4"C-2#12,1#12G CONTROL PANEL #1 20 A -- 360 VA 0 VA -- 20 A SPARE 6

3 744 VA 0 VA -- 20 A SPARE 4

3/4"C-2#12,1#12G EFFLUENT PUMP #1 20 A --

744 VA 0 VA -- 20 A SPARE 2

CKT HOME RUN LOAD NAME TRIP

INT

TYPE

A B A B

INT

TYPE

TRIP LOAD NAME HOME RUN CKT

(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)

ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A

MOUNTING SURFACE WIRES 3 BUS RATING 100 A

LOCATION COMFORT STATION #1,5 LIFT STATION VOLTS 120/240 SINGLE AIC RATING 10,000

(N) BRANCH PANEL C1

TOTAL LOAD (AMPS) 10 7

TOTAL LOAD (VA) 1128 VA 768 VA

PHASE A PHASE B Notes:

17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18

15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16

13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14

11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12

9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10

7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8

5 3/4"C-2#12,1#12G CONTROL PANEL #2 20 A -- 360 VA 0 VA -- 20 A SPARE 6

3 768 VA 0 VA -- 20 A SPARE 4

3/4"C-2#12,1#12G EFFLUENT PUMP #2 20 A --

768 VA 0 VA -- 20 A SPARE 2

CKT HOME RUN LOAD NAME TRIP

INT

TYPE

A B A B

INT

TYPE

TRIP LOAD NAME HOME RUN CKT

(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)

ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A

MOUNTING SURFACE WIRES 3 BUS RATING 100 A

LOCATION COMFORT STATION #2 VOLTS 120/240 SINGLE AIC RATING 10,000

(N) BRANCH PANEL C2

TOTAL LOAD (AMPS) 10 7

TOTAL LOAD (VA) 1104 VA 744 VA

PHASE A PHASE B Notes:

17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18

15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16

13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14

11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12

9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10

7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8

5 3/4"C-2#12,1#12G CONTROL PANEL #3 20 A -- 360 VA 0 VA -- 20 A SPARE 6

3 744 VA 0 VA -- 20 A SPARE 4

3/4"C-2#12,1#12G EFFLUENT PUMP #3 20 A --

744 VA 0 VA -- 20 A SPARE 2

CKT HOME RUN LOAD NAME TRIP

INT

TYPE

A B A B

INT

TYPE

TRIP LOAD NAME HOME RUN CKT

(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)

ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A

MOUNTING SURFACE WIRES 3 BUS RATING 100 A

LOCATION COMFORT STATION #3 VOLTS 120/240 SINGLE AIC RATING 10,000

(N) BRANCH PANEL C3

TOTAL LOAD (AMPS) 10 7

TOTAL LOAD (VA) 1104 VA 744 VA

PHASE A PHASE B Notes:

17 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 18

15 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 16

13 -- SPACE -- -- 0 VA 0 VA -- -- SPACE -- 14

11 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 12

9 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 10

7 SPARE 20 A -- 0 VA 0 VA -- -- SPACE -- 8

5 (N) 3/4"C-2#12,1#12G (N) CONTROL PANEL #5 20 A -- 360 VA 0 VA -- 20 A SPARE 6

3 744 VA 0 VA -- 20 A SPARE 4

(N) 3/4"C-2#12,1#12G (N) EFFLUENT PUMP #5 20 A --

744 VA 0 VA -- 20 A SPARE 2

CKT HOME RUN LOAD NAME TRIP

INT

TYPE

A B A B

INT

TYPE

TRIP LOAD NAME HOME RUN CKT

(LABEL PANELBOARDS ACCORDING TO NAMING CONVENTIONS LISTED IN ELECTRICAL SPECIFICATIONS)

ENCLOSURE NEMA 3R CIRCUITS 18 MAIN BREAKER 50 A

MOUNTING SURFACE WIRES 3 BUS RATING 100 A

LOCATION COMFORT STATION #5 VOLTS 120/240 SINGLE AIC RATING 10,000

(N) BRANCH PANEL C5

1. PROVIDE AND INSTALL NEW BREAKER LOCKABLE IN THE "OFF" POSITION.

KEYNOTES

NOTE#

W V

W V

P

IN

E

1 14" O AK

88" O AK

70" O AK

70" O AK

56" O AK

18" SYCAM O RE

20" SYCAM

OR E

16" TR

EE

24" TR

EE

48" OA

K

3 9-12" TRE

E

60" OA

K

30" PINE

13" PINE

24" O AK

10" OA

K

12" TR

EE

32" O AK

48" OA

K

12" PINE

17" PINE

50" STU

MP

0 14" O

AK

8 5-7" TRE

E

8" OA

K

14" TR

EE

3 14-19

" TRE E

PIPE86.31

PIPE 18 PVC86.33

FL86.23

FL86.29

FL86.19

TEL88.34

TEL88.34

TEL88.35

TEL88.33

TEL88.31

TEL88.30

TEL

88.24

TEL88.26

TEL88.27

TEL88.27

TEL88.28

TEL88.27

TEL88.28

325341

ELEC88.59

88.526BFP

88.529BFP

88.527BFP

88.525BFP

88.162BENCH88.156BENCH

G ATE

G ATE

G ATE

G ATE

SEPTIC

SEPTIC

SE

PTIC

SE

PTIC

SE

PTIC

SE

PTIC

SEPTIC

SEPTIC

SE

PTIC

SE

PTIC

S

S

S

S

S

S

S

S

S

S

FH D

Y

H

W V

W V

W V

O S W

W V

O S W

D

Y

H

W V

D

YH

O S W

O S W

O S W

O S W

O S W

BIN

BIN

BIN

BIN

S O

W

S O

W

S O

W

(E) COMFORT STATION #5

(E) COMFORT STATION #3

(E) COMFORT STATION #2

(E) COMFORT STATION #1

(E) VISITOR CENTER

(E) PG&E POLE W/RISER

(E) PNL A

C A

LI

FO

RN

IA

CAMPGROUND ROAD

C A

M

PG

RO

U N

D R

O A

D

CAM

PGROUND ROAD

(E) SWBD A

(N) PB #4

(N) PB #5

(N) PB #6

(N) PB #8

(N) PB #7

(N) PB #11

(N) PB #10

(N) PB #15

(N) PB #16

(N) PB #14

ENLARGED VIEW

E2

CALIF

O

RNIA

E4

,TYP.

E3

E3

E3

E3

E4

TYP.,

E4

1TYP.,

(N) PB #9

(N) PB #12

(N) PB #13

E4

ENLARGED VIEW

ENLARGED VIEW

ENLARGED VIEW

ENLARGED VIEW

(N) UTILITY RISER

(E) UTILITY POLE W/

(N) UTILITY XFMR

(N) METER PNL B

(N) (2) 4"C-EMPTY (UTILITY XFMR : METER PNL B)

C

ALIF

O

RNIA

E4

TO (N)

PULLBOX #16

(N) 2"C-3#2/0,1#6G (METER PNL B : PNL C5)

(N) GROUND RODS

E4

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EE

R

ST AT E O F C A L I F O R N IA

No. E22549

EL ECT R I CAL

B R Y A

N

SE

NRABM I C H A LE

PACE

ENGINEERING

REDDING, CALIFORNIA

SUB SHEET NO.DESIGNED:

TECH. REVIEW:

DATE:

SHEET

PMIS/PKG NO.

DRAWING NO.

OF

TITLE OF SHEET

148519

DCG, INC.

SEATTLE, WA

253759

PINNACLES NATIONAL PARK

C L o c a l R e v it F ile s \2

.0

E

P in n a c le s N a ti o n a l P a rk

L k c .r v t

/1

/2

:2

:1

P

M

ELECTRICAL SITE PLAN

E2 02/16/22

KC

BB

BB

2423-2499, PINNACLES HWY, PAICINES, CA 95043

EAST SIDE CAMPGROUND

1. PATHWAYS AND RACEWAYS DIRECTLY RELATED TO THE FEEDER CONDUCTORS IN THE

DISTRIBUTION SYSTEM ARE SHOWN ON THE SITE PLAN. REFER TO THE ONE-LINE DIAGRAM

AND ENLARGED PLANS FOR CALLOUTS REGARDING CONDUIT/CONDUCTOR

INFORMATION.

2. TRENCH ADJACENT TO EXISTING CREEK CULVERT. REPAIR SURFACES WHERE NECESSARY TO

MATCH EXISTING CONDITIONS. SEE DETAIL 3, SHEET E4 FOR ADDITIONAL INFORMATION.

3. PROVIDE AND INSTALL CONDUIT SEALING BUSHINGS AT LOCATIONS SHOWN.

4. PROVIDE AND INSTALL IN ACCORDANCE WITH UTILITY REQUIREMENTS.

5. DIRECTIONALLY BORE UNDER HIGHWAY, AND PROVIDE AND INSTALL NEW CONDUIT IN

ACCORDANCE WITH UTILITY REQUIREMENTS.

6. NEW RACEWAY SHALL BE ROUTED ALONGSIDE THE WATER LINE IN THE SAME TRENCH.

MAINTAIN ADEQUATE DISTANCE BETWEEN PIPING SYSTEMS PER ELECTRICAL

SPECIFICATIONS.

7. TRENCH ADJACENT TO EXISTING ROAD. REPAIR SURFACES WHERE NECESSARY TO MATCH

EXISTING CONDITIONS. SEE DETAIL 3, SHEET E4 FOR ADDITIONAL INFORMATION.

KEYNOTES

NOTE

E21" = 100'-0"

1ELECTRICAL SITE PLAN

1. REFER TO SPECIFICATION SECTION 260526, "GROUNDING AND BONDING FOR ELECTRICAL

SYSTEMS" FOR ADDITIONAL GROUNDING AND BONDING REQUIREMENTS AT

UNDERGROUND TRENCHING, PULLBOXES, ABOVE GROUND ENCLOSURES AND OTHER

STRUCTURES.

2. WHERE TRENCHING ACROSS EXISTING ASPHALT, CONCRETE, OR GRAVEL ROADS OR

PATHWAYS, REPAIR SURFACES TO MATCH EXISTING CONDITIONS.

GENERAL NOTES

# NOTE

E21" = 20'-0"

2ENLARGED SITE PLAN

WV

WV

S SEPTIC

S SEPTIC

B I N

D

Y

H

FH

W V

TO EW

88. 65

B I N

87.92

CP PK&W

88.09

88.06

S SEPTIC

S SEPTIC

S O

W

COMFORT

STATION 5

(N) EFFLUENT PUMP #5

(N) 3/4"C-2#12,1#12G

(CONTROL PNL #5 : EFFLUENT PUMP #5)

(N) PNL C5

E4

,TYP.

(N) 2"C-3#2/0,1#6G

(METER PANEL B : PNL C5)

(N) CONTROL PANEL #5

E4

(N) GND ROD

(N) (2) 3/4"C-2#12,1#12G

(CONTROL PNL #5 : PNL C5)

TO

(N) PB #15

(N) PB #14

(E) COMFORT

STATION 1

C A M

PG

RO

UN

D R

O A D

(N) PNL C1

(E) PNL A

(N) EFFLUENT PUMP #1

E4

(N) 2"C-3#3,1#8G (PNL A : PNL C1)

(N) 3/4"C-2#12,1#12G

(CONTROL PNL #1 : EFFLUENT PUMP #1)

(E) VISITOR CENTER

E4

,TYP.

(N) CONTROL

PANEL #1

(N) GND ROD

(N) (2) 3/4"C-2#12,1#12G

(CONTROL PNL #1 : PNL C1)

(N) PB #2

(N) PB #1

(N) PB #2

(E) COMFORT

STATION 2

(N) PNL C2

E4

(N) PB #6

TO (N) PB #7

TO

(N) PB #5

(N) 1 1/2"C-3#4,1#8G (SWBD A : PNL C2)

(N) 2"C-3#2/0,1#6G (SWBD A : PNL C3)

(N) EFFLUENT PUMP #2

(N) 3/4"C-2#12,1#12G

(CONTROL PNL #2 : EFFLUENT PUMP #2)

E4

,TYP.

E4

(N) CONTROL PANEL #2

TYP.,

(N) GND ROD

(N) (2) 3/4"C-2#12,1#12G

(CONTROL PNL #2 : PNL C2)

E4

TYP.,

COMFORT

STATION 3

CAMPGROUND ROAD

(N) PNL C3

(NEMA 3R)

(N) 2"C-3#2/0,1#6G

(PNL C3 : SWBD A)

(N) EFFLUENT PUMP #3

(N) 3/4"C-2#12,1#12G

(CONTROL PNL #3 : EFFLUENT PUMP #3)

E4

E4

,TYP.

(N) CONTROL PANEL #3

(N) GND ROD

(N) (2) 3/4"C-2#12,1#12G

(CONTROL PNL #3 : PNL C3)

(N) PB #13

TO

(N) PB #12

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EE

R

ST AT E O F C A L I F O R N IA

No. E22549

EL ECT R I CAL

B R Y A

N

SE

NRABM I C H A LE

PACE

ENGINEERING

REDDING, CALIFORNIA

SUB SHEET NO.DESIGNED:

TECH. REVIEW:

DATE:

SHEET

PMIS/PKG NO.

DRAWING NO.

OF

TITLE OF SHEET

148519

DCG, INC.

SEATTLE, WA

253759

PINNACLES NATIONAL PARK

C L o c a l R e v it F ile s \2

.0

E

P in n a c le s N a ti o n a l P a rk

L k c .r v t

/1

/2

:2

:2

P

M

ENLARGED POWER PLANS

E3 02/16/22

KC

BB

BB

2423-2499, PINNACLES HWY, PAICINES, CA 95043

EAST SIDE CAMPGROUND

1. PROVIDE AND INSTALL CONDUIT SEALING BUSHINGS AT LOCATION SHOWN.

2. NEW RACEWAY SHALL BE ROUTED ALONGSIDE THE SEWER LINE IN THE SAME TRENCH.

MAINTAIN ADEQUATE DISTANCE BETWEEN PIPING SYSTEMS PER ELECTRICAL

SPECIFICATIONS.

KEYNOTES

NOTE

E31/16" = 1'-0"

4COMFORT STATION 5 POWER PLAN

E31/32" = 1'-0"

1COMFORT STATION 1 POWER PLAN

E31/16" = 1'-0"

2COMFORT STATION 2 POWER PLAN

E31/16" = 1'-0"

3COMFORT STATION 3 POWER PLAN

1. REFER TO SPECIFICATION SECTION 260526, "GROUNDING AND BONDING FOR ELECTRICAL

SYSTEMS" FOR ADDITIONAL GROUNDING AND BONDING REQUIREMENTS AT

UNDERGROUND TRENCHING, PULLBOXES, ABOVE GROUND ENCLOSURES AND OTHER

STRUCTURES.

2. PROVIDE AND INSTALL ALL MATERIALS FOR THE CONTROL PANEL AND PUMP PER THE

MANUFACTURER'S INSTALLATION INSTRUCTIONS.

3. WHERE TRENCHING ACROSS EXISTING ASPHALT, CONCRETE, OR GRAVEL ROADS OR

PATHWAYS, REPAIR SURFACES TO MATCH EXISTING CONDITIONS.

GENERAL NOTES

# NOTE

FINISH GRADE

D

2"MIN2"MIN

WARNING

TAPE

COMPACTED

TRENCH

BACKFILL

12"

BACKFILL W/ SAND

HAND TAMP

M

IN

M

IN

M

IN

NOTES:

1. D=3" MIN FOR 2" AND LARGER CONDUIT

2. D=2" MIN FOR 1 1/2" AND SMALLER CONDUIT

3. CONDUIT DETAIL FOR LESS THAN 4 RACEWAYS PER TRENCH

EXOTHERMIC WELD CONNECTION,

THERMOWELD, CADWELD, OR EQUAL

#4 BARE CU CONDUCTOR

NOTES:

1. ANCHOR EQUIPMENT TO CONCRETE PAD USING HILTI HY200 EPOXY AND

TORQUE IN ACCORDANCE WITH ESR-3187.

#4@12" MAX

6" CLR, TYP. ALL SIDES

ANCHOR, TYP.

METER

PEDESTAL

CONCRETE PAD

EARTH

FINISHED GRADE

3" , TYP.

WIDTH/DEPTH AS REQUIRED

C

LR

3" , TYP.

OUTDOOR PEDESTAL PAD

C

LR

10"

APPROX. WT.

35 LBS.

GND

BUS

GROUND ROD, MIN. 6'-0" SEPARATION,

SEE DETAIL 5, THIS SHEET

6"

6"

24" MIN

PEA GRAVEL OR 3/4"

MINUS CRUSHED ROCK.

ELECTRICAL PULLBOX

AND EXTENSIONS AS

REQUIRED

UNDERGROUND

DUCT, TYP.

FINISHED GRADE

COVER

A

A

VIEW A-A

PVC SECTION

CONCRETE

FILL

LENGTH AS REQ.

(E) CREEK SECTION

(N) CONDUIT/CONDUCTORS

PVC -GRS COUPLING, TYP.

GRS SECTION

PVC SECTION

CONCRETE FILL

PEA GRAVEL OR

3/4" CRUSHED ROCK

FINISHED GRADE

1'-0" MIN.

M

IN

FRONT SIDE - VIEW A-A

1/4" DIAMETER HILTI KWIK BOLT TZ 304 STAINLESS STEEL

WEDGE ANCHOR WITH MINIMUM 3" EMBEDMENT INTO

STRUCTURE, TYP. 4 (EACH CABINET)

CMU OR CONCRETE STRUCTURE

FASTEN CABINET USING 1/4" GALVANIZED FASTENER

INTO 1/4" STRUT CHANNEL CONE NUT; COORDINATE

FINAL NUMBER, LOCATION AND BOLT

CONFIGURATIONS WITH LISTED MANUFACTURER

MOUNTING HOLE LOCATIONS

FINISHED FLOOR

NOTE:

1. TYPICAL PANELBOARD CABINET MAY VARY IN WIDTH AND LENGTH. THIS DETAIL SHALL ACCOUNT FOR LARGEST AND HEAVIEST PANELBOARD AVAILABLE, BUT FASTENING AND ANCHORAGE SHALL BE USED EQUALLY FOR SMALLER CABINET CONFIGURATIONS.

2. WHERE MANUFACTURER REQUIRES A THIRD FASTENING LOCATION, PROVIDE ADDITIONAL STRUT CHANNEL AND FASTENERS.

MATCH ADDITIONAL STRUT CHANNEL WITH OTHERS SHOWN (THIS DETAIL).

3. MAXIMUM BREAKER HANDLE HEIGHT SHALL BE 78".

12 GA, 13/16" GALVANIZED STRUT CHANNEL,

TYP.; CUT STRUT CHANNEL FOR NO REVEAL

OUTSIDE OF CABINET

1" CONDUIT KNOCKOUT, TYP.

(CONDUIT SHALL MATCH KNOCKOUT SIZE IF

MANUFACTURER VARIES)

CONDUIT RACEWAY BETWEEN PANELBOARD

AND CONTROL PANEL WHERE REQUIRED, TYP.

(SEE PLANS AND SPECIFICATIONS); SIZE AND

NUMBER AS REQUIRED (SEE NOTES, THIS DETAIL)

A

A

PANELBOARD

MAXIMUM

WEIGHT 250 LBS

FEEDER SIZE PER ONE-LINE DIAGRAM

TO

CONTROL

PANEL

CONTROL

PANEL

MAXIMUM

WEIGHT

50 LBS

TO

PANELBOARD TO EQUIPMENT

CONDUIT QUANTITIES

PER PLAN, TYP.

5'-0" MAXIMUM

2" GALVANIZED PIPE CAP, TYP.

1-5/8" X 1 5/8" DEEP GALVANIZED CHANNEL STRUT, 12

GAUGE SLOTTED, B-LINE B225H OR APPROVED EQUAL

2" DIA X 10' SCHEDULE 40 GALVANIZED STEEL PIPE (ASTM A53 GR.B)

CONCRETE

FOOTING

3'-0"

4'-3"

CONDUIT

AS SHOWN

5'-0"

12"

DIA

FINISHED GRADE

1 5/8" x 13/16 GALVANIZED

CHANNEL STRUT SPRING NUT WITH

1/2" x 1" GALVANIZED BOLT, TYP.

(B-LINE B525H OR EQUAL)

2" GALVANIZED PIPE CLAMP, B-LINE

B2400-2 OR APPROVED EQUAL

3'-9"

VERTICAL STRUT ATTACHED

TO HORIZONTAL, TYP.

CONTROL PANEL

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EE

R

ST AT E O F C A L I F O R N IA

No. E22549

EL ECT R I CAL

B R Y A

N

SE

NRABM I C H A LE

PACE

ENGINEERING

REDDING, CALIFORNIA

SUB SHEET NO.DESIGNED:

TECH. REVIEW:

DATE:

SHEET

PMIS/PKG NO.

DRAWING NO.

OF

TITLE OF SHEET

148519

DCG, INC.

SEATTLE, WA

253759

PINNACLES NATIONAL PARK

C L o c a l R e v it F ile s \2

.0

E

P in n a c le s N a ti o n a l P a rk

L k c .r v t

/1

/2

:2

:2

P

M

ELECTRICAL DETAILS

E4 02/16/22

KC

BB

BB

2423-2499, PINNACLES HWY, PAICINES, CA 95043

EAST SIDE CAMPGROUND

NTS E4

2UNDERGROUND CONDUIT

NTS E4

4CABLE TO GROUND ROD

NTS E4

6METER PEDESTAL MOUNTING DETAILS

NTS E4

5PULLBOX - PULL THROUGH

NTS E4

3CONCRETE FILL - PVC TO GRS SECTION

NTS E4

1PANELBOARD SURFACE MOUNTING CMU AND CONCRETE CONSTRUCTION

NTS E4

7OUTDOOR EQUIPMENT MOUNTING ASSEMBLY

R

EG

IS

TE

RE

D

PROFESSIONAL

ENG

IN

EE

R

ST AT E O F C A L I F O R N IA

No. E22549

EL ECT R I CAL

B R Y A

N

SE

NRABM I C H A LE

PACE

ENGINEERING

REDDING, CALIFORNIA

SUB SHEET NO.DESIGNED:

TECH. REVIEW:

DATE:

SHEET

PMIS/PKG NO.

DRAWING NO.

OF

TITLE OF SHEET

148519

DCG, INC.

SEATTLE, WA

253759

PINNACLES NATIONAL PARK

C L o c a l R e v it F ile s \2

.0

E

P in n a c le s N a ti o n a l P a rk

L k c .r v t

/1

/2

:2

:2

P

M

TITLE 24 ELECT. DIST.

COMPLIANCE DOCUMENTS

E5 02/16/22

KC

BB

BB

2423-2499, PINNACLES HWY, PAICINES, CA 95043

EAST SIDE CAMPGROUND

File details come from the government source that posted it. Updated .