2020-419_NPS_JELA_303851_HVAC_M20_detached_-_Sheet_-_M601_-_DIAGRAMS_0002.pdf
PDF 90 KB Posted
- Attached to
- JELA - INSTALL AIR COOLED CHILLER - PACC
- Solicitation number
- 140P5221R0051
About this file
This document includes a federal contract opportunity solicitation and related technical drawings. The solicitation is for the installation of a new air-cooled chiller system at the Prairie Acadian Cultural Center located within Jean Lafitte National Historical Park and Preserve. The solicitation number is 140P5221R0051 and is seeking construction services to install the chiller system. The technical drawings labeled M601 - Diagrams provide details for the new chilled water supply and return piping as well as related HVAC components. Key aspects of the installation shown on the diagrams include connecting the new chiller to existing air handling unit number one, routing the air separator drain, and reusing existing pipe hangers for the chilled water piping. The opportunity is available through the National Park Service Southeast Region within the Department of the Interior.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P5221R0051_Amd_0004.pdf | ||
| Sol_140P5221R0051_Amd_0003.pdf | ||
| Sol_140P5221R0051_Amd_0002.pdf | ||
| RFI_-_Responses_0001.pdf | ||
| Sol_140P5221R0051_Amd_0001.pdf | ||
| Proposal_Submission_Package.docx | DOCX document | |
| A06_-_Specifications.pdf | ||
| Sol_140P5221R0051.pdf | ||
| B03_-_DOL_Wage_Determination.pdf | ||
| Provisions_and_Clauses_-_8_5_21.pdf | ||
| Past_Performance_Worksheet.pdf | ||
| A06_-_Drawings.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS-2
B-1
ET-1
AS-1
DP
HWS
HWR
CWR
CWS
ET-2
CH-1
CHP-1 CHP-2
BT-1
HWP-1
HWP-2
DP DP DP
DP
DP
DP DP
M
HWR
HWR
HWS
HWS
DCW
D C
W
M
CF-1
DCW FROM
MAIN
AHU-1 (EXISTING)
HWS
HWR
CWS
CWR
/1 M503
/4 M501
CF-2
LEGEND: FLOW DIAGRAM
SYMBOL
DESCRIPTION
Anchor, main
Butterfly Valve
Pressure gauge and cock
PS Pressure switch
Thermometer
Control Valve, 3-Way
Union
Reducer
Flexible Connection
Thermometer well, only
Flow Meter
Check Valve
Triple Duty Valve
DP
DP Differential Pressure Switch
Pressure Reducing Valve
M Motorized Two-Way Valve
Strainer
DATE:
TECH REVIEW:
DESIGNED: SUB SHEET NO. DRAWING NO.
PMIS/PKG NO.
SHEET
OF
LOCATION WITHIN PARK
TITLE OF SHEET
A/E FIRM
CROFT &
ASSOCIATES
KENNESAW,
GEORGIA
/2
/2
:2
:3
P
M
DIAGRAMSM601
P. GORDY
P. GORDY
M. JOHNSON
9 9
PRAIRIE ACADIAN CULTURAL BUILDING XX
XXXXXX
303852B
JEAN LAFITTE NATIONAL HISTORIC PARK2021/02/12
M601
1 WATER PIPING FLOW DIAGRAM
PIPING PLAN KEYNOTES
2 EXISTING RPZA. SEE DETAIL FOR EXISTING RPZA
LOCATION
7 ROUTE AIR SEPARATOR DRAIN TO NEAREST FLOOR
DRAIN AS SHOWN ON DRAWINGS
10 HEATING HOT WATER SUPPLY AND RETURN TO EXISTING
VAV BOXES. HOT WATER CONTROLLED WITH 3-WAY
VALVE.
15 NEW CHILLED WATER SUPPLY AND RETURN. REUSE
EXISTING PIPE HANGERS.
X
| Sheets |
| M601 - DIAGRAMS |
File details come from the government source that posted it. Updated .