FOMC_HAMP_Inventory_Alarm_Monitoring_Services.xlsx
XLSX spreadsheet 32 KB Posted
- Attached to
- FOMC/HAMP ALARM MONITORING
- Solicitation number
- 140P4224R0001
About this file
This document contains details regarding a federal contract opportunity for fire and intrusion alarm monitoring services at two National Park Service sites. The solicitation seeks to award a firm-fixed price contract with one base year and four option years to provide additional equipment, supervision, and staffing to monitor, test, and maintain alarm systems at Fort McHenry National Monument and Historic Site and Hampton National Historic Site. A site visit is scheduled for January 23, 2024 at 9:30 AM and questions are due by January 26, 2024 to the contract specialist. The opportunity is set aside for small businesses and issued by the Department of the Interior National Park Service Northeast Region. An attached statement of work further describes the required alarm monitoring and maintenance services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_0003_Attachment_4_Pricing_Sheet_0003.xlsx | XLSX spreadsheet | |
| Sol_140P4224R0001_Amd_0003.pdf | ||
| Sol_140P4224R0001_Amd_0002.pdf | ||
| Sol_140P4224R0001_Amd_0001.pdf | ||
| Attachment_2_WD_2015-4265.pdf | ||
| Pricing_Sheet_Alarm_Monitoring_Services.xlsx | XLSX spreadsheet | |
| Experience_Questionnaire.docx | DOCX document | |
| Attachment_1_SOW.pdf | ||
| Sol_140P4224R0001.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Parks Monitored Alarm Systems
| FACP-Fire Alarm Control Panel IDS-Intrusion Detection System FACP in IDS- Fire Alarms Monintored with Intrusion Detection System | Security Devices | Fire Devices | Initiation Devices | ||||||||||||||||||||||||||||||||
| Park | Building | FMSS Location # | Panel Type | Panel Model | Suppression System Type | Date Installed | Approximate # of Contact Points | Window / Door Contacts | PIR | Glass Break | Tampers | Panic | Temp /Humidity | Water Sensor | Fire Annunciator Panels | Fire Zones | Bells | Horns | Fire Lights | Horn Strobes | Fire Phones | Speakers | Emergency Lights | Manual Stations | Smoke Detectors | Heat Detectors | Duct Smoke Detectors | Flow Switches | Tamper Switches | Low Air Switches | Pressure Switches | Linear Heat Cable | Pressure Tanks | Agent Tank | Comments |
| FOMC | Civil War Powder Magazine | 27446 | FACP | Notifier 3030 | Wet Pipe Sprinkler | 24 | 3 | 3 | 2 | 11 | 3 | 1 | 1 | 14 Spr heads | |||||||||||||||||||||
| FOMC | Civil War Powder Magazine | 27446 | IDS | Moose Z2000 | 9 | 1 | 4 | 1 | 1 | 2 | |||||||||||||||||||||||||
| FOMC | Commanding Officers Quarters (A Building) | 27435 | FACP | Firelite MS-905OUD | Wet Pipe Sprinkler | 25 | 1 | 7 | 3 | 11 | 1 | 2 | 44 Spr Heads | ||||||||||||||||||||||
| FOMC | Commanding Officers Quarters (A Building) | 27435 | IDS | MaxSys Model PC4020 | 7 | 1 | 5 | 1 | |||||||||||||||||||||||||||
| FOMC | Enlisted Mens Bariicks #2 (E Building) | 27444 | FACP | Firelite MS-905OUD | Wet Pipe Sprinkler | 25 | 1 | 0 | 7 | 3 | 11 | 1 | 2 | 60 spr head | |||||||||||||||||||||
| FOMC | Enlisted Mens Bariicks #2 (E Building) | 27444 | IDS | Moose Z2000 | 16 | 5 | 9 | 1 | 1 | ||||||||||||||||||||||||||
| FOMC | Enlisted Mens Barricks #1 (D Building) | 27441 | FACP | Firelite MS-905OUD | Wet Pipe Sprinkler | 22 | 1 | 0 | 8 | 3 | 8 | 1 | 1 | 66 spr heads | |||||||||||||||||||||
| FOMC | Enlisted Mens Barricks #1 (D Building) | 27441 | IDS | MaxSys Model PC4020 | 9 | 4 | 4 | 1 | |||||||||||||||||||||||||||
| FOMC | Junior Officers Quarters (C Building) | 27440 | FACP | Firelite MS-905OUD | Wet Pipe Sprinkler | 19 | 1 | 6 | 2 | 10 | 36 spr heads | ||||||||||||||||||||||||
| FOMC | Junior Officers Quarters (C Building) | 27440 | IDS | MaxSys Model PC4020 | 9 | 1 | 7 | 1 | |||||||||||||||||||||||||||
| FOMC | Sally Port (F Building) | 27445 | FACP in IDS | Moose Z2000 | 9 | 1 | 2 | 1 | 1 | 1 | 3 | ||||||||||||||||||||||||
| FOMC | Visitor And Education Center | 108781 | FACP | Gamewell E3 | Wet Pipe Sprinkler | 153 | 36 | 6 | 92 | 6 | 3 | 2 | 8 | ||||||||||||||||||||||
| FOMC | Visitor And Education Center | 108781 | IDS | DSC | 35 | 11 | 19 | 4 | 1 | ||||||||||||||||||||||||||
| HAMP | Collection Storage Building | 230578 | FACP | Notifier NFS-320 | Dry Pipe Sprinkler | 2012 | 44 | 0 | 0 | 0 | 10 | 5 | 22 | 1 | ? | 2 | 3 | 1 | 83 Spr Heads | ||||||||||||||||
| HAMP | Collection Storage Building | 230578 | IDS | 2012 | 17 | 9 | 5 | 3 | |||||||||||||||||||||||||||
| HAMP | Green Metal & Pole Barn Systems | 27591 | FACP | Silent Knight Model SK-5208 | None | 2001 | 22 | 3 | 15 | 4 | |||||||||||||||||||||||||
| HAMP | Green Metal & Pole Barn Systems | 27591 | IDS | MaxSys Model PC4020 | 2001 | 16 | 11 | 4 | 1 | ||||||||||||||||||||||||||
| HAMP | Long Barn | 27416 | FACP | Notifier NFS-320 | FM200 | 36 | 4 | 2 | 25 | 1 | 2 | 2 | 4 Nozzles | ||||||||||||||||||||||
| HAMP | Long Barn | 27416 | IDS | DSC | 12 | 5 | 4 | 1 | 2 | ||||||||||||||||||||||||||
| HAMP | Lower House (Covers 5 buildings below) | 27407 | FACP | Notifier SFP-10UD | Wet Pipe Sprinkler | 34 | 2 | 3 | 5 | 14 | 2 | 6 | 2 | 10 Spr Heads | |||||||||||||||||||||
| HAMP | Lower House (Covers 5 buildings below) | 27407 | IDS | DSC | 21 | 12 | 4 | 4 | 1 | ||||||||||||||||||||||||||
| HAMP | Mansion | 27391 | FACP | Notifier Model NFS-640 | Wet and Dry Pipe Sprinkler | 103 | 24 | 8 | 46 | 3 | 9 | 2 | 9 | 1 | 1 | 185 Spr Heads | |||||||||||||||||||
| HAMP | Mansion | 27391 | IDS | DSC | 46 | 13 | 32 | 1 | |||||||||||||||||||||||||||
| HAMP | Orangery | 27402 | FACP in IDS | MaxSys Model PC4020 | 30 | 4 | 4 | 3 | 1 | 3 | 2 | 1 | 12 | ||||||||||||||||||||||
| HAMP | Stalbes 1 & 2 System | 27404 | FACP | Notifier NFS-320 | Dry Pipe Sprinkler | 20 | 4 | 1 | 9 | 3 | 1 | 1 | 1 | 81 Spr Heads | |||||||||||||||||||||
| HAMP | Stalbes 1 & 2 System | 27405 | IDS | DSC | 14 | 8 | 5 | 1 | |||||||||||||||||||||||||||
| HAMP | Visitor Contact Station | 229824 | FACP | Notifier NFS-320 | None | 2014 | 32 | 9 | 3 | 17 | 3 | ||||||||||||||||||||||||
| HAMP | Visitor Contact Station | 229824 | IDS | NAPCO Gemini | 2014 | 10 | 3 | 6 | 1 |
Data
| N/A | DSC | ||||||||||||||||||||||||||
| Park | Panel Type | Building | FMSS Location # | System Type | FACP | MaxSys Model PC4020 | Date Installed | Fire Through Intrusion alarm | Bells | Horns | Fire Lights | Horn Strobes | Fire Phones | Speakers | Emergency Lights | Manual Stations | Smoke Detectors | Heat Detectors | Duct Smoke Detectors | Flow Switches | Tamper Switches | Low Air Switches | Pressure Switches | Linear Heat Cable | Pressure Tanks | Agent Tank | Comments |
| IDS | Moose Z2000 | ||||||||||||||||||||||||||
| FOMC | FACP in IDS | NAPCO Gemini | |||||||||||||||||||||||||
| HAMP | Gamewell E3 | ||||||||||||||||||||||||||
| Firelite MS-905OUD | |||||||||||||||||||||||||||
| Notifier 3030 | |||||||||||||||||||||||||||
| Notifier NFS-320 | |||||||||||||||||||||||||||
| Silent Knight Model SK-5208 | |||||||||||||||||||||||||||
| Notifier Model NFS-640 | |||||||||||||||||||||||||||
| Notifier SFP-10UD |