This document appears to be a set of detailed drawings for a project related to the Monocacy National Battlefield Visitor Center. The drawings provide specifications for Scene 2, which includes a map and projection pillar exhibit. Key details include:

The projection pillar will feature a 84" x 48" reflective projection screen, with a 38" x 82" title panel, 30" x 62" raised lettering graphic, and three 6" x 9" caption monitors. The pillar will have a 2" reveal and recessed area accessible from the back for wheelchair access to a 32" x 24" topographic map. There is an option for an additional monitor and speakers to play the same video/audio program.

This set of drawings appears to be supporting a federal contract opportunity with Solicitation Number 140P2124R0069, titled "HAFC MONO AV BATTLE MAP" and issued by the Department of the Interior National Park Service. No additional details on the scope, timeline, or pricing terms are provided in this document.

View the file

Other files for this federal contract opportunity

Other files attached to HAFC MONO AV BATTLE MAP, newest first.
File Type Posted
Sol_140P2124R0069_Amd_0001.pdf PDF
MONO-IMG_0223_0001.pdf PDF
Attachment_C_NPSAmendmentToLicenseAgreement.docx DOCX document
Sol_140P2124R0069.pdf PDF
Attachment_B_NPSMaterialsReleaseForm.doc DOC document
Attachment_L_ElectricMapText_110723.doc DOC document
Attachment_M_HFC_SDH_Specifications_02152024.docx DOCX document
Attachment_E_NPSProgrammaticAccessibility.docx DOCX document
Attachment_A_NPSIndividualReleaseForm.doc DOC document
Attachment_D_NPS2021StyleGuide.pdf PDF
Attachment_F_RequirementsForCompletionReport.doc DOC document
Attachment_G_FileNamingConventions.pdf PDF
Attachment_H_FolderStructure.docx DOCX document
Attachment_I_ContractPricingForm.xlsx XLSX spreadsheet
Attachment_J_MONOparkmap.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Monocacy National Battlefield | Visitor Center | Drawings: Production Design 2 • REVISED August 19, 2023 5

New Exhibits Overview

Storage closet

SCENE 4

SC

EN

E

SC

EN

E

SC

EN

E

SCENE 3

SCENE 6

Attachment K

Monocacy National Battlefield | Visitor Center | Drawings: Production Design 2 • REVISED August 19, 2023 20

Scene 2: Map and Projection Pillar

SCALE: 1/32: 3/8” = 1’ except where noted

FRONT

LEFT SIDE ELEVATION

PLAN

Concept

FRONT ELEVATION 1/16 Scale

120”

95”

106”

27”

19”

19” recessed area accesed from back of pillar

2” reveal in pillar finish material 4, continues lines of handrail.

Wooden rail Maple (Material 5) 8” deep x 2” high

Entire projection pillar finished in material 4, natural finish, except where noted

Title panel: 38” x 82” Recessed 1” from face frame

Finish: Material 4, Early American stain

Title graphic raised lettering

GL-02-01-050

30” x 62” CNC 1/2” thick,Material 4

Natural finish

Bezel height 10”

Support Structure

2 x 2 Aluminum Channel

12” x 30” Media control cabinet

Cam lock or similar

Rail Perimeter 142” x 106”

2 x 2 Aluminum channel Support beneath rail

Directional Speakers (6) 3” x 3”

Directional Speakers 3” x 3”

6 x 9 Caption Monitors (3) Center on bezels

Bezel 9.75” wide (plan view) Black HPL, Matte finish

Program start button (3)

Bezel Perimeter 104” x 69”

46” 3.

Reflective Screen 84” x 48”

Projection boom

Projection boom

Projector

Projector

Projection Pillar 48 x 46

Recessed area in pillar, accessible from backJuly

Bezel should be constructed to prevent sag of the projection screen

Monocacy National Battlefield | Visitor Center | Drawings: Production Design 2 • REVISED August 19, 2023 21SCALE: 1/32

Scene 2: Map and Projection Pillar

RIGHT SIDE ELEVATION

95”

120”

27”

19”

19” recessed area accesed from back of pillar

2” reveal in pillar finish material 4, continues lines of handrail.

Projection boom

Projector

GL-02-01-200

24” x 33”

Direct print to veneered plywood

Monocacy National Battlefield | Visitor Center | Drawings: Production Design 2 • REVISED August 19, 2023 22SCALE: As Noted

CE-02-01-100

32” x 24” x 2”(base) topographic map extends 5” beyond back of pillar

CE-02-01-100

32” x 24” x 2”(base) topographic map extends 5” beyond back of pillar

38” 38”

19” Recess area in pillar allows roll-under for wheelchair access to topo map

19” Recess area in pillar allows roll-under for wheelchair access to topo map

BACK

Scene 2: Map and Projection Pillar

Option

Optional monitor and speakers play same video and audio program as large projection surface

Monocacy National Battlefield | Visitor Center | CONTENT UPDATE • October 30, 2023 12

Scene 2 Map Experience — Dimensional View

Scene 2 - Map projection view

MONO-VC-PD2_Scene2
Pages from MONO VC PD2 Graphics_Content_Update_10.30.23