This document is a technical specification section for pedestrian control devices, specifically focusing on outdoor removal stanchions. The specification details the Visiontron Stainless Steel Outdoor Loop Post, Model ST620, which features a 304 Alloy Stainless Steel post measuring 40-42" tall with a 2" diameter, including four 4-3/4" stainless steel welded loops and an accessibility-compliant mid-post loop design. The post base is designed to be removable from concrete plaza surfaces, and a 3/16-inch polished stainless steel chain is specified. Installation requirements include proper concrete plaza preparation, following manufacturer's instructions for post spacing and placement, and ensuring a neat installation free of defects. The document also outlines submittal requirements such as product data, manufacturer's certification, and warranty documentation.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Issued: September 5, 2025
CASA 324271 10 45 00 - 1
Pedestrian Control Devices
SECTION 10 45 00 - PEDESTRIAN CONTROL DEVICES
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Outdoor, removal stanchions
1.2 SUBMITTALS
A. See Section 01 33 23 for submittal procedures.
B. Product Data: Provide manufacturer's product information on post material, chain, and post base/footing.
C. Manufacturer's Certification: Submit manufacturer's certification that materials comply with specified requirements and are suit
D. Warranty Documentation: Submit manufacturer's standard warranty.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Basis of Design: Visiontron Stainless Steel Outdoor Loop Post, Model ST620
2.2 MATERIALS
A. Components and Dimensions:
1. Post:
a. Material: 304 Alloy Stainless Steel.
b. Height: 40"-42".
c. Diameter: 2".
d. Loops: 4-3/4" Stainless Steel, welded to post.
1) Accessibility compliant mid-post loops required.
e. Post base to be removable from concrete plaza.
2. Chain: 3/16-inch polished stainless steel
PART 3 EXECUTION
3.1 EXAMINATION
A. Do not begin installation until new plaza concrete has been properly prepared.
3.2 INSTALLATION
A. Install in accordance with manufacturer's instructions.
B. Set posts in accordance with manufacturer's recommended spacing.
3.3 FIELD QUALITY CONTROL
A. See Section 01 40 00 - Quality Requirements for additional requirements.
B. Layout: verify post layout is accurate to design.
C. Workmanship: verify neat installation, free of defects.
Issued: September 5, 2025
CASA 324271 10 45 00 - 2
Pedestrian Control Devices
3.4 CLOSEOUT ACTIVITIES
A. See Section 01 77 00 for close out procedures.
END OF SECTION 10 45 00