B09_Amd_05_Attach_38_GOGA_311373_Complete_CD_Drawings_2023_08_07_Part4_0005.pdf

PDF 20 MB Posted

Attached to
GOGA 311373 Alcatraz Prison Hospital Wing Seismic
Solicitation number
140P2024R0025
Issued by

About this file

This document provides details for a federal solicitation opportunity to seismically stabilize and renovate the hospital wing of Alcatraz Prison. The solicitation number is 140P2024R0025 from the Department of the Interior National Park Service National Office. Under this opportunity, contractors are invited to bid on seismic stabilization and renovation work for the historic prison hospital wing located on Alcatraz Island in San Francisco Bay. An attachment to the solicitation provides construction drawings of the existing hospital wing that contractors can reference in developing their proposals. Proposals are due by August 7, 2023 for consideration in awarding a contract to complete the seismic upgrades and renovation of the Alcatraz Prison Hospital Wing.

View the file

Other files

File Type Posted
B09_Amd_12_Q_A__84_Temporary_Move_Items_0012.xlsx XLSX spreadsheet
B09_Amd_12_Existing_Lighthouse_E2_0012.jpeg JPEG file
B09_Amd_12_Updated_Drawings_for_Additional_Areas_to_Paint_0012.pdf PDF
B09_Amd_12_Wage_Determination_Update_4_11_24_0012.pdf PDF
B09_Amd_12_GOGA_311373_Solicitation_Q_A_Final_0012.xlsx XLSX spreadsheet
Sol_140P2024R0025_Amd_0012.pdf PDF
Sol_140P2024R0025_Amd_0011.pdf PDF
B09_Amd_10_Sign_in_sheet_3_28_24_0010.pdf PDF
B09_Amd_10_Site_Visit_Tri_Fold_GOGA_311373_rev1_0010.pdf PDF
Sol_140P2024R0025_Amd_0010.pdf PDF
Sol_140P2024R0025_Amd_0009.pdf PDF
B09_Amd_9_GOGA_311373_Prebid_Site_Visit_Instructions_20240328_0009.docx DOCX document
Temporary_Bookstore_Design__0009.zip ZIP file
B09_Amd_08_GOGA_311373_Solicitation_QA_TO_POST_0008.xlsx XLSX spreadsheet
Sol_140P2024R0025_Amd_0008.pdf PDF
B09_Amd_07_GOGA_311373_Solicitation_QA_3_0007.xlsx XLSX spreadsheet
Sol_140P2024R0025_Amd_0007.pdf PDF
B09_Amd_07_SF30_140P2024R0025_0007.pdf PDF
Sol_140P2024R0025_Amd_0006.pdf PDF
B09_Amd_06_SF30_140P2024R0025_0006.pdf PDF
B09_Amd_06_GOGA_311373_Solicitation_QA_2_0006.xlsx XLSX spreadsheet
B09_Amd_05_Attach_40_GOGA_311373_Complete_CD_Drawings_2023_08_07_Part6_0005.pdf PDF
B09_Amd_05_Attach_37_GOGA_311373_Complete_CD_Drawings_2023_08_07_Part3_0005.pdf PDF
B09_Amd_05_Attach_41_GOGA_311373_Complete_CD_Drawings_2023_08_07_Part7_0005.pdf PDF
B09_Amd_05_Attach_36_GOGA_311373_Complete_CD_Drawings_2023_08_07_Part2_0005.pdf PDF
B09_Amd_05_Attach_39__GOGA_311373_Complete_CD_Drawings_2023_08_07_Part5_0005.pdf PDF
B09_Amd_05_Solit_Clauses_Construction_GOGA_311373_0005.docx DOCX document
Sol_140P2024R0025_Amd_0005.pdf PDF
B09_Amd_05_Attach_35_GOGA_311373_Complete_CD_Drawings_2023_08_07_Part1_0005.pdf PDF
B09_Amd_05_SF30_140P2024R0025_0005.pdf PDF
B09_Amd_05_Attach_34_Final_Specifications_GOGA_311373_0005.pdf PDF
B09_Amd_04_SF30_140P2024R0025_0004.pdf PDF
B09_Amd_04_Attach_29_Subcontracting_Plan_0004.doc DOC document
B09_Amd_04_GOGA_311373_Solicitation_QA_1_0004.xlsx XLSX spreadsheet
B09_Amd_04_Solit_Clauses_Construction_GOGA_311373_0004.docx DOCX document
Sol_140P2024R0025_Amd_0004.pdf PDF
B09_Amd_03_Attach_GOGA_311373_Alcatraz_Historic_Structures_Sign-in_0003.pdf PDF
Sol_140P2024R0025_Amd_0003.pdf PDF
B09_Amd_03_Attach_Site_Visit_Tri_Fold_GOGA_311373_0003.docx DOCX document
B09_Amd_03_SF30_140P2024R0025_0003.pdf PDF
B09_Amd_02_Solit_Clauses_Construction_GOGA_311373_0002.docx DOCX document
Sol_140P2024R0025_Amd_0002.pdf PDF
B09_Amd_02_SF30_140P2024R0025_0002.pdf PDF
Sol_140P2024R0025_Amd_0001.pdf PDF
B09_Amd_01_SF30_140P2024R0025_0001.pdf PDF
B09_Amd_01_Attach_33_GOGA_311373_Prebid_Site_Visit_insructions_0001.docx DOCX document
B08_Attach_04_CLIN_Diagram.pdf PDF
B08_Attach_11_Langan_Geotechnical_Report.pdf PDF
B08_Solit_Clauses_Construction_GOGA_311373(3).docx DOCX document
B08_Attach_18_PV_SBS___Flashing_Specification.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

" "0 e "' Cl.

u .E ..

N e ~ z

$PARAPET

I

I T ~

I

I

,3

~ . >---~-~ <1 • ..

WIRING AFTER COMPLETION OF STRUCTURAL AND ~v ~ _

ARCHITECTURAL WORK, lYPICAL. CONTRACTOR TO VERIFY 1<1 .•

ALL CONDITIONS IN FIELD PRIOR TO CONSTRUCTION. .., <I

REINSTALL ALL ELECTRICAL EQUIPMENT, CONDUIT AND-----...~•~·•····:. 4 " .• _,i _ • .., 4 ·-b -~ .., 4 ,4

... 1111 4 • • 4 • 4 • ·4

$FL2

$FL1

$BSMT

==I==

.,_, .. <I!

' • ·• I

• ,3 .., c_ . ::, .<j ~

~ 4 ., ,3 ..

<I

<1' .

<I

4 <I . 41 • •. n -

_<1 ··Qr'

'!1 ,• .• -

V

I

I

I

I

. I

,\ 1' ~ \ I

\I • \ I

/\ X I\ •. /\ .

, ------------1 t------1 I \ f--------t ••

4 ' l,i • . .'. ~ .

@ GL 3 INTERIOR ELEVATION ELECTRICAL

SCALE@

~ESSt

~ ~'<-RT sr-i § Qco

No E235B4

I

I

0 4 8

SCALE OF FEET

DESIGNED: SUB SHEET NO.

RJS

@f..1 ■1 ■1

JLR

E240 TECH. REVIEW:

JWM

DATE:

08/07/23

SHEET NOTES

A. REFER TO STRUCTURAL,

STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION AND

LOCATIONS OF WORK.

8. CATALOG, TAG, AND STORE ANY

CONDUIT AND DEVICES TO BE

REMOVED AND REINSTALLED DURING

STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL

WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL,

STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK.

D. PAINT (N) INTERIOR ELECTRICAL

ELEMENTS TO MATCH (E) COLOR(S).

REFER TO SPECIFICATION SECTION

09 90 00 "PAINTING".

KEYED NOTES<D

1. REMOVE AND REINSTALL (E) STACKED

RECEPTACLE AND SWITCH AS

REQUIRED TO ALLOW FOR NEW SHEAR

WALL. INTERCEPT AND EXTEND

EXISTING CONDUIT AND WIRING AS

REQUIRED TO MAINTAIN CONNECTIVllY.

2. REMOVE AND REINSTALL (E) GUTTER

AND DISCONNECT AS REQUIRED TO

ALLOW FOR NEW SHEAR WALL.

INTERCEPT AND EXTEND EXISTING

CONDUIT AND WIRING AS REQUIRED

TO MAINTAIN CONNECTIVllY.

3. REMOVE AND REINSTALL (E)

ABANDONED CONDUIT AND GUTTER AS

REQUIRED TO ALLOW FOR NEW SHEAR

WALL.

4. REMOVE AND REINSTALL (E)

ABANDONED ELECTRICAL EQUIPMENT

AS REQUIRED TO ALLOW FOR NEW

SHEAR WALL.

5. REMOVE AND REINSTALL (E) JUNCTION

BOX AS REQUIRED TO ALLOW FOR

NEW SHEAR WALL. INTERCEPT AND

EXTEND EXISTING CONDUIT AND

WIRING AS REQUIRED TO MAINTAIN

CONN ECTIVllY.

TITLE OF SHEET DRAWING NO.

GL 3 641

180012

INTERIOR ELEVATION PMIS/PKG NO.

ELECTRICAL 311373

SHEET

ALCATRAZ ISLAND

GOLDEN GATE NATIONAL RECREATION AREA 186 OF224

" "0 e "' Cl.

u .E ..

N e ~ z

$PARAPET

$FL2

$FL1

$BSMT

..... ,ii; ..

.. •• • •• ~ :41, ll:I 4 4 ~· ... □ .. .' 04 1 r::::J(1 .. , ~--- .:, • 4 )=1 . .:....,... . 4 -□ -~ ~- - -· :E.... ::::! - 4..,__ □_ - "-"'-" -

-- .. .a:,□

,d ~ 4 ..,__ ·,q, CJ

V

5 ./

@ GL 10 INTERIOR ELEVATION ELECTRICAL

',i .. ,4 . ·.

• 4 ·- • ' . .; .. ,· .. "' .. _.,.

,.,_--:~. ,. .Q ...

<I' ..

<I .. •

:· ·:I

. q ,6 .• cf ·-·

-, 4 : " 4 ' -_ ~ ~:.

.. .., ~ l

.. .. ,6 <I <I

<I <I ..

p ... " 4

4 .4 . . <I

<I ..

<14 ~ ·-"' ..

.. 4 •

,6 ' . <I

.. <1 •

<I.

<I

<i 4. 4 4

<I

<I 4

. ·4

<I. ..

. <I -· ,6 . •.

V

SCALE@

SHEET NOTES

A. REFER TO STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL

DRAWINGS FOR ADDITIONAL

INFORMATION AND LOCATIONS OF

WORK.

8. CATALOG, TAG, AND STORE ANY

CONDUIT AND DEVICES TO BE

REMOVED AND REINSTALLED DURING

STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL

WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL,

STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK .

D. PAINT (N) INTERIOR ELECTRICAL

ELEMENTS TO MATCH (E) COLOR(S).

REFER TO SPECIFICATION SECTION

09 90 00 "PAINTING".

KEYED NOTES<D

1. REMOVE AND REINSTALL (E)

ELECTRICAL DEVICE AS REQUIRED TO

ALLOW FOR NEW SHEAR WALL.

INTERCEPT AND EXTEND EXISTING

CONDUIT AND WIRING AS REQUIRED

TO MAINTAIN CONNECTIVITY.

2. REMOVE AND REINSTALL (E) JUNCTION

BOX AS REQUIRED TO ALLOW FOR

NEW SHEAR WALL. INTERCEPT AND

EXTEND EXISTING CONDUIT AND

WIRING AS REQUIRED TO MAINTAIN

CONNECTIVITY.

3. REMOVE AND REINSTALL (E) JUNCTION

BOX AND CONDUIT AND WIRING TO

ALLOW FOR STRUCTURAL

RE-ENFORCING WORK. INTERCEPT AND

EXTEND CONDUIT AND WIRING AS

REQUIRED TO MAINTAIN CONNECTIVITY .

4. REMOVE AND REINSTALL (E) EXIT SIGN

AND BUG-EYE FIXTURE TO ALLOW FOR

STRUCTURAL RE-ENFORCING WORK.

INTERCEPT AND EXTEND CONDUIT AND

WIRING AS REQUIRED TO MAINTAIN

CONNECTIVITY.

5. REMOVE AND REINSTALL (E) NOT IN

USE TEAR GAS ENCLOSURE AND

RECEPTACLE TO ALLOW FOR

STRUCTURAL RE-ENFORCING WORK.

0 4 8

SCALE OF FEET

DESIGNED: SUB SHEET NO. TITLE OF SHEET DRAWING NO.

RJS

No E235B4 TECH. REVIEW:

JWM E260

DATE:

08/07/23

GL 10

INTERIOR ELEVATION

ELECTRICAL

ALCATRAZ ISLAND

GOLDEN GATE NATIONAL RECREATION AREA

180012

PMIS/PKG NO.

311373

SHEET

187 OF224

i "' C:

'i e

" "O e u .E

" (II

cp I

I n

I 0 0

I I lO -cp I

I u

I I I

"' '(~50. ea ea 50.: ry- - ;51. ea ea

I I I

DI ID DI

SHEET NOTES

A. REFER TO ARCHITECTURAL, STRUCTURAL

ENCLOSURE, AND STRUCTURAL DRAWINGS

FOR LOCATIONS AND EXTENTS OF

EXTERIOR FACADE WORK.

8. CATALOG, TAG, AND STORE ANY CONDUIT

AND DEVICES TO BE REMOVED AND

REINSTALLED DURING STRUCTURAL,

STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL WORK.

C. ALL CONDUIT SIZES SHOWN ARE

APPROXIMATE BASED ON SITE PHOTOS.

CONTRACTOR REQUIRED TO FIELD VERIFY

ALL SIZES DURING THE DOCUMENTED

REMOVAL STAGE.

D. PREPARE AND REPAINT (E) EXTERIOR

EXPOSED CONDUIT, FIXTURES, BOXES,

COVERS, AND OTHER STEEL ATTACHMENTS

TO MATCH (E) COLOR(S). REFER TO

SPECIFICATION SECTION 09 90 00

"PAINTING".

i/

0 ™ ™

I I

51.: ry- ea ~52. D- - "'52 . ., ea

I I

ID DI ID

cp cp er cp cp cp cp I I 1 I I i/ 1 I I

I I I I I I I

I

I I

I I 0 ™ ~ 0 0 ~ ™ 0 ~ ~ 0 0 0

[ I I I I I I I ID I I I I I I

1111111 1111111 1111111 I

- "'253. V "' ea ~53.: ry - - 1254. "' ea ,a54.~ ry ea - 1255. - "' f55.~ ry ea "' '(~56. Dea ea 56.: ~- ea ~57. - - , 57.: ea ea ✓, - - l58.' ea ]58. - ~ ~ - - ~ ~ ~ - - ~ ~ ~ ~ ~ ~- ~ - - ~ ~ ~ - - ~

I I I I I I I I I I I I

I . I f . . .. -- 0

~ \~\STRATION 8Utt.o p,..O l'1\7t.~

DI ID ~59 DI ID DI

@ EXTERIOR ELEVATION ADMINISTRATION WING SOUTH - ELECTRICAL

E

KEYED NOTES<D

1. REMOVE AND REINSTALL EXISTING

HISTORIC LIGHT FIXTURE. REFER TO

DETAIL 5/A514.

• h-11--e

===1•1111 llllltt:::mw :t~:t:::::

11111111111111111111111111:::::::n ~

KEY PLAN

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

A

~ESS/~

R>'-RT sr-1

ID

DESIGNED:

RJS

@1•1•1•1

JLR

TECH. REVIEW:

JWM

DATE:

08/07/23

DI ID DI ID

119091 o 4 8 4

SCALE@ --------

SCALE OF FEET

SUB SHEET NO. TITLE OF SHEET

EXTERIOR ELEVATION

ADMINISTRATION WING [401 SOUTH ELECTRICAL -

ALCATRAZ ISLAND

GOLDEN GATE NATIONAL RECREATION AREA

DRAWING NO.

180012

PMIS/PKG NO.

311373

188 OF224

"O e u .E en

0p I

I I I I '

I I

0 0 0 □ 0 ,.

I I I I I I I I

' J

I

I I I I I I

I

□DD

~ T

□DD □ -I I I I

@ADMINISTRATION WING EAST- ELECTRICAL

E

SHEET NOTES

A. REFER TO ARCHITECTURAL,

STRUCTURAL ENCLOSURE, AND

STRUCTURAL DRAWINGS FOR

LOCATIONS AND EXTENTS OF

EXTERIOR FACADE WORK.

B. CATALOG, TAG, AND STORE ANY

CONDUIT AND DEVICES TO BE

REMOVED AND REINSTALLED DURING

STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL

WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL,

STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK.

C. ALL CONDUIT SIZES SHOWN ARE

APPROXIMATE BASED ON SITE

PHOTOS. CONTRACTOR REQUIRED TO

FIELD VERIFY ALL SIZES DURING

THE DOCUMENTED REMOVAL STAGE.

D. PREPARE AND REPAINT (E)

EXTERIOR EXPOSED CONDUIT,

FIXTURES, BOXES, COVERS, AND

OTHER STEEL ATTACHMENTS TO

MATCH (E) COLOR(S). REFER TO

SPECIFICATION SECTION 09 90 00

"PAINTING".

KEYED NOTES<D

1. EXISTING SURFACE MOUNTED CONDUIT

SERVING IN-USE LIGHT FIXTURE.

REMOVE FOR CONCRETE REPAIR WORK

AND REINSTALL AT COMPLETION.

REFER TO A/SE202 FOR EXTENT OF

CONCRETE REPAIR SCOPE.

2. REMOVE AND REINSTALL EXISTING

CONDUIT AND WIRING AS NECESSARY

TO ALLOW FOR CONCRETE REPAIR

WORK. REFER TO A/SE202 FOR

EXTENT OF CONCRETE REPAIR SCOPE.

I

I I

F -

I

I

I

I

I/ ----,,. 2 ti

V V ...

r- I'

KEY PLAN

!ii111111111111ll•IIII llllltllllltl

111111111111111•1111 IIIIIIIIIIIIIR ·;:::...:--

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

No E235B4

SCALE@

4 0 4 8 -- ----

SCALE OF FEET

DESIGNED: SUB SHEET NO. TITLE OF SHEET DRAWING NO.

RJS

TECH. REVIEW:

JWM

EXTERIOR ELEVATION 641

180012

ADMINISTRATION WING [402 PMIS/PKG NO.

EAST - ELECTRICAL 311373

SHEET

DATE:

08/07/23

189 OF224 GOLDEN GATE NATIONAL RECREATION AREA

SHEET NOTES

A. REFER TO ARCHITECTURAL, STRUCTURAL

ENCLOSURE, AND STRUCTURAL DRAWINGS FOR

LOCATIONS AND EXTENTS OF EXTERIOR FACADE

WORK.

B. CATALOG, TAG, AND STORE ANY CONDUIT AND

DEVICES TO BE REMOVED AND REINSTALLED

DURING STRUCTURAL, STRUCTURAL ENCLOSURE,

AND ARCHITECTURAL WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL WORK.

C. ALL CONDUIT SIZES SHOWN ARE APPROXIMATE

BASED ON SITE PHOTOS. CONTRACTOR

REQUIRED TO FIELD VERIFY ALL SIZES DURING

THE DOCUMENTED REMOVAL STAGE.

D. PREPARE AND REPAINT (E) EXTERIOR EXPOSED

CONDUIT, FIXTURES, BOXES, COVERS, AND

OTHER STEEL ATTACHMENTS TO MATCH (E)

COLOR(S). REFER TO SPECIFICATION SECTION

09 90 00 "PAINTING".

11111111

II

11111111

11111111

I I I I I I I I

11 11

11111111

II

11111111

11111111

I I I I I I I I

11 11

Gp

0 0 0

I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 11

11 11 11111111 11 I 11 I

124 126

@ EXTERIOR ELEVATION CELLHOUSE PARTIAL WEST - ELECTRICAL

E

KEYED NOTESCD

1. EXISTING HISTORIC ELECTRICAL BOX.

REMOVE AND REINSTALL AS REQUIRED

TO ALLOW FOR CONCRETE REPAIR.

REFER TO 1/SE205 FOR EXTENT OF

AND CONCRETE REPAIR SCOPE.

2. PROTECT IN PLACE EXISTING

ELECTRICAL BOX.

===11111111111111111111N ---c, -

IIIIIIIIINIIIIIII II llllllll;:1111=1" ..,?---=:

KEY PLAN No E235B4

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

I I I I I I I I

11 I

DESIGNED: SUB SHEET NO.

RJS

[405

DATE:

08/07/23

SCALE@ 0~~~4iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiil8

SCALE OF FEET

TITLE OF SHEET

EXTERIOR ELEVATION

CELLHOUSE PARTIAL

WEST - ELECTRICAL

ALCATRAZ ISLAND

GOLDEN GATE NATIONAL RECREATION AREA

DRAWING NO.

180012

PMIS/PKG NO.

311373

190 OF224

I

I

I 1- 1- 200""1- '= '= L-L-

I

I

I

1, 0 I• " -s - I 100 ~

I

I II 000 ~L L

I II

RI

SHEET NOTES

A. REFER TO ARCHITECTURAL, STRUCTURAL ENCLOSURE,

AND STRUCTURAL DRAWINGS FOR LOCATIONS AND

EXTENTS OF EXTERIOR FACADE WORK.

8. CATALOG, TAG, AND STORE ANY CONDUIT AND

DEVICES TO BE REMOVED AND REINSTALLED DURING

STRUCTURAL, STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK. REINSTALL AFTER COMPLETION

OF STRUCTURAL, STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK.

I

I

C. ALL CONDUIT SIZES SHOWN ARE APPROXIMATE BASED

ON SITE PHOTOS. CONTRACTOR REQUIRED TO FIELD

VERIFY ALL SIZES DURING THE DOCUMENTED

REMOVAL STAGE.

D. PREPARE AND REPAINT (E) EXTERIOR EXPOSED

CONDUIT, FIXTURES, BOXES, COVERS, AND OTHER

STEEL ATTACHMENTS TO MATCH (E) COLOR(S). REFER

TO SPECIFICATION SECTION 09 90 00 "PAINTING".

c:::::a u

" I

I

1-1- 201'"'" 1-1- 2021,.1- ' ' ~~ • I I I

I I I I

I, I• I, I• I, 101 102 L

I

001 -l--l--l l~"====a=,======a!!:-ir==='d:::===a;r-!'====a=,======a!ba~.====aal l •···ta= =;,===a

I

I

105>

II II II II II II = "' , .. II II II II II II

II

71 i:;:i

[IJ[IJ ~ I II I

I rr, 11--------cp

I ' .... 119 --

I

P-------'--------

, 4

I

I, "· .. +-- -t-1::l.J.J..ilUJ

02q

@ EXTERIOR ELEVATION CELLHOUSE & HOSPITAL PARTIAL NORTH - ELECTRICAL

KEYED NOTES<D

1. EXISTING HISTORIC ELECTRICAL BOX.

REMOVE AND REINSTALL AS REQUIRED

TO ALLOW FOR CONCRETE REPAIR.

REFER TO 1/SE206 FOR EXTENT OF

CONCRETE REPAIR SCOPE.

2. PROTECT IN PLACE EXISTING IN USE

ELECTRICAL CONDUIT AND LIGHT

FIXTURE.

3. REMOVE (E) CONDUIT AND WIRING ON

(E) RETAINING WALL AND REINSTALL

ON (N) REC YARD WALL. REFER TO

1/SE206.

4. REMOVE AND REINSTALL (E) EXISTING

CONDUIT AND WIRING AS REQUIRED

TO ALLOW FOR PILASTER

STRENGTHENING. REFER TO 1 /SE206.

===11•1111 llllltllllltl

===11111111111 IIIIIIH,::HH::::IR..,J'--'~=:

KEY PLAN

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

DESIGNED:

RJS

No E235B4 TECH. REVIEW:

JWM

DATE:

08/07/23

I I I

I I I

I I I

I I

I I

I

I I I

I I I

I I I

I I I

I I

11!

I

I h1 I

I

' --121

' I, I, 021, cp

I a d

I D

I Q

SCALE@ 4~~~0~~~4-.iiiiiiiiiiiiiiiiiiiiiiiiiiiia

SCALE OF FEET

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

[406 EXTERIOR ELEVATION 18i6~ 2

CELLHOUSE & HOSPITAL PMIS/PKG NO.

PARTIAL NORTH - ELECTRICAL 1---

31-137- 3

--1

ALCATRAZ ISLAND SHEET

GOLDEN GATE NATIONAL RECREATION AREA 191 OF224

e u .E cp cp cp cp cp cp cp 1 1 1

0 0 0 I

• m • ====================================================================;,========== m

I

I

I

I

I

I

0 -~ ~· I

I

I

I

I

' ' I '

I '

:19L I ' ' ' tr I '

L9 3 - ... .,94 -- ,95. ... -- l95.' .. 96. i ... ... .. '96. -.. 297. -- .. .. 297.: - - -- ...... -- -- - -.. -- .... -- -- -- .. - .. -, I I I I I I n._ DOOOl)()()C)CI I DOOOl)()()()CI D000l)000CI

' I' , , I' , I' , ,- /~ ,- ;- - ~~ ~~ -- · 192 -- ,,.

,. 193 FF e,. ,,.

194 -- e,.

: 195.1 -e- --, 95.

FF ,,.

.)96.t

F e,.

~96.: ~: - - 197

~~ ... ... '- _.J -- ... - ... - - ... ... ... ... ... - - .. -,_, '-~ ,_~ >--~ ' -

I' , I' , I I

,,_____________G ~ I r (E) , " =- IT

, r (E) 3/4" coNDu1T

\ I

, , 11 ' , I - - ' ,: '\ a - 093: ,094~ 095.

CJ CJ a - CJ a -

96. J I

1ll+-l-'=-~ 1+-1<0'95.'})l.4 I -~-,1

I ~~~ .... 109~5·::::~dlaaaaaa_,,_aaaaj...1-i

' I - -

' (D--- V

@ EXTERIOR ELEVATION HOSPITAL PARTIAL EAST - ELECTRICAL

E

SHEET NOTES

A. REFER TO ARCHITECTURAL, STRUCTURAL ENCLOSURE,

AND STRUCTURAL DRAWINGS FOR LOCATIONS AND

EXTENTS OF EXTERIOR FACADE WORK.

B. CATALOG, TAG, AND STORE ANY CONDUIT AND

DEVICES TO BE REMOVED AND REINSTALLED DURING

STRUCTURAL, STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK. REINSTALL AFTER COMPLETION

OF STRUCTURAL, STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK.

C. ALL CONDUIT SIZES SHOWN ARE APPROXIMATE BASED

ON SITE PHOTOS. CONTRACTOR REQUIRED TO FIELD

VERIFY ALL SIZES DURING THE DOCUMENTED

REMOVAL STAGE.

D. PREPARE AND REPAINT (E) EXTERIOR EXPOSED

CONDUIT, FIXTURES, BOXES, COVERS, AND OTHER

STEEL ATTACHMENTS TO MATCH (E) COLOR(S). REFER

TO SPECIFICATION SECTION 09 90 00 "PAINTING".

KEYED NOTESCD

1. REMOVE AND REINSTALL EXISTING

HISTORIC LIGHT FIXTURE. REFER TO

DETAIL 5/A514.

2. EXISTING 3/4" CONDUIT TO BE

REMOVED AND REINSTALLED TO ALLOW

FOR PILASTER STRENGTHENING. REFER

TO A/SE2O9 FOR EXTENT OF

PILASTER STRENGTHENING AND

CONCRETE REPAIR SCOPE.

3. PROTECT IN PLACE EXISTING IN USE

ELECTRICAL CONDUIT AND LIGHT

FIXTURE.

KEY PLAN

~111mm11111 1111m1111ttw --

" Ill I Ill II Ill 111111111111111 R •

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

-0

--e

II I

• 299 ~

II I

I

I .

DESIGNED:

RJS

No E235B4 TECH. REVIEW:

JWM

DATE:

08/07/23 l b Ill

I

SCALE@

4 0 4 8 --------

SCALE OF FEET

SUB SHEET NO. TITLE OF SHEET

EXTERIOR ELEVATION

HOSPITAL PARTIAL [409 EAST - ELECTRICAL

ALCATRAZ ISLAND

GOLDEN GATE NATIONAL RECREATION AREA

DRAWING NO.

180012

PMIS/PKG NO.

311373

192 OF224

LJJ

LJJ

0 -i::!i ...I

LJJ -;:;

tS .B

:! --"' i::!i C:

'j ~ e iii

31: ., "O e "' 0.

u • E

N e " u c..

z

IN

IN

IN

IN

IN

..0

" u

" t .i::

0 c.. ., I.:::

c..

I") I") o-i

I I") (/)

,:,ig

~o

IZ

::,~ .., a::

I .

- LJJ

I") :g C: .., " .. ::. ilj' .. "O "O., !1t :i::

o.2 O>C..

.; E

..9 re-c,,c;?

.. I")

"O c;'.i I ...I I") LJJ IN wo

ON - .

LJJ I")

ai-E ::, ".., z .. ., "'" ,50 ...... eo

CIC..

~ cp cp

(E) 1" CONDUIT CD 1

I - I I I

1 1 1 I _ I I

I~ n 0 Ll 0

I = '/ I

J -- - :=J

I . ' ' I /

I' , ' ' I/ r

.!.86 _a, ,LB 8 F F .. ~ ?89 ..... '? 90 ... ,.. 29 1~

FF FF F F F _,.

F F

,- r r ' ,- r ' ' ® I' , I

I I I

Cl 4,1;1 CONDUI Cl v-(E) CD V

I

I

. , I' . ' ' .

I' II

" - I/ - I/ - ' -, I/ - - IF FF ,. r' Fr F 1-F F FF ,. r' 1 F I 186 187 188 189 190 19 1,- ~

I'-,./ '"'"

I',./ '"'" I-~ ..... I-~ FF

[\ r ~ '" ,,, I'- r I\., I lg

I I

I

I ~(E) 1" COND JITSQ) - -

I • 0 0 0 0 0 0

F ' '

I~

~ ~ I - -I ! ' , ' I' '

' , ' I'

I~

,oa· , 1088' 089~ 1090~ ~09 t -, I

I = ~ ,= I D8 6 r, r, r, r, r, r, r, r, I

4 • • •. ·' ·.•

.... :· -'!,1' 181 \. ,.·•, £ ~. _ _._ ... ® .. ·-: • ..

@ EXTERIOR ELEVATION HOSPITAL WING PARTIAL EAST - ELECTRICAL

E

SHEET NOTES

A. REFER TO ARCHITECTURAL, STRUCTURAL

ENCLOSURE, AND STRUCTURAL DRAWINGS FOR

LOCATIONS AND EXTENTS OF EXTERIOR FACADE

WORK.

B. CATALOG, TAG, AND STORE ANY CONDUIT AND

DEVICES TO BE REMOVED AND REINSTALLED

DURING STRUCTURAL, STRUCTURAL ENCLOSURE,

AND ARCHITECTURAL WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL WORK.

C. ALL CONDUIT SIZES SHOWN ARE APPROXIMATE

BASED ON SITE PHOTOS. CONTRACTOR

REQUIRED TO FIELD VERIFY ALL SIZES DURING

THE DOCUMENTED REMOVAL STAGE.

D. PREPARE AND REPAINT (E) EXTERIOR EXPOSED

CONDUIT, FIXTURES, BOXES, COVERS, AND

OTHER STEEL ATTACHMENTS TO MATCH (E)

COLOR(S). REFER TO SPECIFICATION SECTION

09 90 00 "PAINTING".

KEYED NOTES©

1. REMOVE AND REINSTALL EXISTING

HISTORIC LIGHT FIXTURE. REFER TO

DETAIL 5/A514.

2. EXISTING VERTICAL CONDUITS TO BE

REMOVED AND REINSTALLED TO ALLOW

FOR CONCRETE REPAIR WORK. REFER

TO A/SE210 FOR EXTENT OF

CONCRETE REPAIR SCOPE.

3. EXISTING 1" CONDUITS TO BE

REMOVED AND REINSTALLED TO ALLOW

FOR CONCRETE REPAIR WORK. REFER

TO A/SE210 FOR EXTENT OF

CONCRETE REPAIR SCOPE.

4. EXISTING HORIZONTAL CONDUITS AND

JUNCTION BOX TO BE REMOVED AND

REINSTALLED TO ALLOW FOR

CONCRETE REPAIR WORK. REFER TO

A/SE210 FOR EXTENT OF CONCRETE

REPAIR SCOPE.

5.

6.

7.

EXISTING ELECTRICAL BOX AND

ASSOCIATED CONDUITS TO BE

REMOVED AND REINSTALLED TO

ALLOW FOR CONCRETE REPAIR WORK.

REFER TO B/SE210 FOR EXTENT OF

CONCRETE REPAIR SCOPE.

EXISTING 1" CONDUIT TO BE

REMOVED AND REINSTALLED TO

ALLOW FOR CONCRETE REPAIR WORK.

REFER TO B/SE210 FOR EXTENT OF

CONCRETE REPAIR SCOPE.

EXISTING CONDUITS UP TO ROOF TO

BE REMOVED AND REINSTALLED AS

REQUIRED TO ALLOW FOR CONCRETE

REPAIR WORK. REFER TO B/SE21 0

FOR EXTENT OF CONCRETE REPAIR

SCOPE.

I

I

I

I

' I

, I

F .L9, F r .

I' , I

I I

I LJ

I v-ta ,. ,. 192 1-1-

I '" '" '"I', I

I

I

I

I

= I F µ

I ea r, I I

KEY PLAN

I I I

I ~ ]ii :-,. ' ' I

I 0 ,, 0 II

I I I I - I I ,_

I ?85 -- I

I

C ,,,.

I

I ' ' 298

C ,,.

~ I

I I I I I

I I

II

Cl Cl II

II

II

II

r-

I \ F F 185 ,-. F I

I I

I I

I I ' I • I" I" I

198 ,.. ,..

I

I I ' I

' 5 I ---...

I~~ ' I ' I Ii - --n r . I I

I I

I ~

I;-=:

I~

'T I '-c-'-

I• • , I L---- I L

I r· - - -- ,· -7

I

' ' I , 7

' ,,' \ I' I

' _J I

085 098 I

I \ - -- -· -, I r· - - -- ' -,

- - - --' I

J I I I

• .•. C • .· ... - . .. 4

I' . ... -: ,,; ... . . . ..... . QI

EXTERIOR ELEVATION CELL HOUSE PARTIAL

NORTH - ELECTRICAL

LLLLLI..! ..

BLDG.

SCALE@

4 0 4 8

I

I I

I I

'° t -

NO SCALE NOTE: POCHE INDICATES AREA OF WORK SCALE OF FEET

DESIGNED: SUB SHEET NO, TITLE OF SHEET DRAWING NO,

No E235B4

RJS

TECH, REVIEW:

JWM [410

EXTERIOR ELEVATION 1ai6~ 2

HOSP & CELL PARTIAL PMIS/PKG NO,

EAST & NORTH - ELECTRICAL 1---

31-13-73 ---;

SHEET

DATE:

08/07/23

GOLDEN GATE NATIONAL RECREATION AREA 193 OF224

Gp Gp 0p I ~~--~ ~ --~~--~--~L.,_-~________G_~ I --r--____., I

0 0 0 0 0 I --t=-=-=,-+---.F'r9' ....... 9'9""..--------+-~---_-~--,JL__-----.""'F'F9'9""......,r---+-~~~~--c__------....F'r9' ....... "F9r------'r;:=_-=--._-~--+-...,.........,F'r9'.,-----+-~---_-~-.c__......,......,.""'F'F,-------J'r-~-_-_-~-.'=I l-l-l'J80 281

,~--< 2 >-------

I _____ ____., 0 0 0 0 0

® EXTERIOR ELEVATION CELLHOUSE PARTIAL EAST - ELECTRICAL

E

SHEET NOTES KEYED NOTES©

A. REFER TO ARCHITECTURAL, STRUCTURAL 1 . REMOVE AND REINSTALL EXISTING

ENCLOSURE, AND STRUCTURAL DRAWINGS FOR HISTORIC LIGHT FIXTURE. REFER TO

LOCATIONS AND EXTENTS OF EXTERIOR FACADE

WORK.

DETAIL 5/A514.

2. EXISTING CONDUIT TO BE REMOVED

B. CATALOG, TAG, AND STORE ANY CONDUIT AND AND REINSTALLED AS REQUIRED TO

DEVICES TO BE REMOVED AND REINSTALLED ALLOW FOR PILASTER STRENGTHENING

DURING STRUCTURAL, STRUCTURAL ENCLOSURE, WORK. REFER TO A/SE211 FOR

AND ARCHITECTURAL WORK. REINSTALL AFTER EXTENT OF SCOPE.

COMPLETION OF STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL WORK. 3. EXISTING IN-USE LIGHT FIXTURE AND

ASSOCIATED CONDUITS TO BE

C. ALL CONDUIT SIZES SHOWN ARE APPROXIMATE REMOVED AND REINSTALLED TO ALLOW

BASED ON SITE PHOTOS. CONTRACTOR FOR CONCRETE REPAIR WORK. REFER

REQUIRED TO FIELD VERIFY ALL SIZES DURING TO B/SE211 FOR EXTENT OF SCOPE.

THE DOCUMENTED REMOVAL STAGE.

PREPARE AND REPAINT (E) EXTERIOR EXPOSED

4. PROTECT IN PLACE EXISTING IN USE

D. ELECTRICAL CONDUIT AND LIGHT

CONDUIT, FIXTURES, BOXES, COVERS, AND FIXTURE.

OTHER STEEL ATTACHMENTS TO MATCH (E)

COLOR(S). REFER TO SPECIFICATION SECTION

09 90 00 "PAINTING".

0-tc l 0-

I I 1 I I I

I I I I I

I I 0 I £

0 0 0 0

I I I I I I I I I I

-µ 277' .. - -.. 278 .. - -... 279 .. -'/ I I

' I ' ' '

I

~ ~ w LJ ' I

I ~ ~ -- ---... 178 .. - - ... 179 .. -,_

I I I

~ 'o 77

' 0

I I

II

ll ~ i ~

I /

L / I

4 ~-. . . . • ... :: ~- .. -

~- ·•' • .• o11., ' :

; _. .. . ' -- ..... ' . ·- ,; .• •-•. A

@ EXTERIOR ELEVATION CELLHOUSE PARTIAL EAST- ELECTRICAL

E411

KEY PLAN

===-1111111m:::m

===-111 IIIIIIIIIIIIIR ;:::,,J---

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

No E235B4

DESIGNED:

RJS

TECH. REVIEW:

JWM

DATE:

08/07/23

SCALE@

4 0 4 8

SCALE OF FEET

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

[411 EXTERIOR ELEVATION 1ai6~ 2

CELLHOUSE PARTIAL PMIS/PKG NO.

EAST & NORTH - ELECTRICAL 1---

31-137- 3

---1

SHEET

GOLDEN GATE NATIONAL RECREATION AREA 194 OF224

e u .E

. ---------,==:i:------~=~ :::i:-------:==~------,=~ ::::i;-----------~==:::i:------:=~ ~-----;r::===:==:- 1 I I

0 0 0 0 0 0 0 0 I I 1 -----,,..........,.....,.,-------,~~~~,.__-Fr"....,.....,..,----_.,~~~~------........ Fr,~~~~~~---,----.,..,........,...,..,----~~~~---r---------. ............... .,......,,----_.,~~~~-------,,..,.......,.,...Fr"r-"~~~~---,-----,...,..,......~,------"~---:__-_-~~=~--,-- ·

I

171 174 175,'l++-I

1 ~

-------+-----'r--------+------'r-------------,'-------'r------~~-------'r------------+------'r------------,'-------'r----- ~---'r----'r-

---------.L----1,....---------.L-----1,...---------,l,--....i.,-----.... --~----------.....-,--...... ----..... --....i;--::;;, ... -:: .. :..--:_.,.,..._::~.--::.i~-,---._. :J---~:;:::=~ ... ;. ' • : ~ ..

@ EXTERIOR ELEVATION CELLHOUSE PARTIAL EAST - ELECTRICAL

E

SHEET NOTES

A. REFER TO ARCHITECTURAL, STRUCTURAL

ENCLOSURE, AND STRUCTURAL DRAWINGS

FOR LOCATIONS AND EXTENTS OF

EXTERIOR FACADE WORK.

8. CATALOG, TAG, AND STORE ANY CONDUIT

AND DEVICES TO BE REMOVED AND

REINSTALLED DURING STRUCTURAL,

STRUCTURAL ENCLOSURE, AND

ARCHITECTURAL WORK. REINSTALL AFTER

COMPLETION OF STRUCTURAL, STRUCTURAL

ENCLOSURE, AND ARCHITECTURAL WORK.

KEYED NOTESCD

1. EXISTING CONDUIT TO BE REMOVED

AND REINSTALLED AS REQUIRED TO

ALLOW FOR PILASTER STRENGTHENING

WORK. REFER TO 1 /SE212 FOR

EXTENT OF SCOPE.

2. EXISTING CONDUIT TO BE REMOVED

AND REINSTALLED AS REQUIRED TO

ALLOW FOR CONCRETE REPAIR WORK.

REFER TO 1/SE212 FOR EXTENT OF

SCOPE. -::-,~.,....; -

I

C. ALL CONDUIT SIZES SHOWN ARE

APPROXIMATE BASED ON SITE PHOTOS.

CONTRACTOR REQUIRED TO FIELD VERIFY

ALL SIZES DURING THE DOCUMENTED

REMOVAL STAGE.

. ---------e SCALE@ 4 0 4 8

D. PREPARE AND REPAINT (E) EXTERIOR

EXPOSED CONDUIT, FIXTURES, BOXES,

COVERS, AND OTHER STEEL ATTACHMENTS

TO MATCH (E) COLOR(S). REFER TO

SPECIFICATION SECTION 09 90 00

"PAINTING".

KEY PLAN

NO SCALE NOTE: POCHE INDICATES AREA OF WORK

No E235B4

DESIGNED:

RJS

TECH. REVIEW:

JWM

DATE:

08/07/23

SUB SHEET NO.

[412

SCALE OF FEET

TITLE OF SHEET

EXTERIOR ELEVATION

CELLHOUSE PARTIAL

EAST - ELECTRICAL

ALCATRAZ ISLAND

GOLDEN GATE NATIONAL RECREATION AREA

DRAWING NO.

180012

PMIS/PKG NO.

311373

195 OF224