Attachment_17__HWD_Bid_Schedule___Est_Quant_Addendum_01_-_09_19_2025_0005.pdf
PDF 862 KB Posted
- Attached to
- GAOA HOT WELL DUNES CAMPGRND IMPRVMNTS
- Solicitation number
- 140L0625B0012
About this file
This document is an Estimated Quantities document for the Hot Well Dunes Recreation Site Improvements project by the Bureau of Land Management. The project involves comprehensive recreation area improvements, including demolition of existing structures (septic tanks, restrooms, shade structures, kiosks), site preparation, road stabilization, and construction of new facilities. Key work includes installing new concrete sidewalks, RV and parking pads, electrical infrastructure with solar panels and solar shade structures, plumbing for hot tubs and water systems, and landscaping with tree removal, fencing, and hydro-seeding.
The document provides detailed estimated quantities for multiple project components across categories like mobilization, demolition, site road stabilization, amenity areas, electrical systems, solar installations, landscaping, and furnishings. The project includes several additive items: road stabilization, tree removal, split rail fence replacement, and hydro-seeding. The estimated quantities are noted as being for informational purposes only, with the contractor responsible for determining final quantities. The project appears to be dated with an Addendum 01 dated 9/19/2025, suggesting future planned improvements for the recreation area.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PAGE LEFT INTENTIONALLY BLANK
Estimated Quantities HOT WELL DUNES RECREATION AREA
Quantity Unit
GC Mobilization incl grading site establishment/prep 1 ls
Silt fence barrier SF 2' high 2x2x14ga wire fabric 8,360 lf Stabilized construction entrance - SCE 2 ea Organic filter barrier / straw wattle barrier - SWB 2,520 lf Roadway sweeping - RS 1 ls Protected storage area - PSA 1 ls Dust Control - DS 215,000 sf
DEMO AND REMOVE SEPTIC TANK; Structure & Vault 1 ea DEMO AND REMOVE ROMTEC RESTROOM STRUCTURE 2 ea DEMO AND REMOVE CABANA SHADE STRUCTURE 7 ea DEMO AND REMOVE KIOSK STRUCTURE 3 ea DEMO AND REMOVE IRON RANGER 1 ea DEMO AND REMOVE CONCRETE SIDEWALK 380 sy DEMO, REMOVE, AND BACKFILL CONCRETE HOT TUBS 2 ea DEMO AND REMOVE FIRE RING 14 ea DEMO AND REMOVE CAMP GRILL 17 ea DEMO AND REMOVE RAIL FENCING 1,386 lf DEMO AND REMOVE BLOCK FENCE PILLARS 52 ea REMOVE EXISTING TRASH CANS 20 ea
EARTHWORK CUT & WASTE (DISTRIBUTED ON SITE) 1,500 cy BASE STABILIZATION AND GRADING 26,000 sy AGGREGATE BASE COURSE-6" 4,330 cy
EARTHWORK CUT & WASTE (DISTRIBUTED ON SITE) 215 cy BASE STABILIZATION AND GRADING 3,100 sy AGGREGATE BASE COURSE-6" 520 cy
NEW 4" CONCRETE SIDEWALK 227 sy
NEW CONCRETE RV PAD 130 sy NEW CONCRETE SHED PAD 30 sy NEW CONCRETE LP PAD 6 sy NEW 250 GAL LP TANK 1 ea NEW 1000 GAL SEPTIC TANK AND LEACH FIELD (119 cy) 1 ls NEW 1-1/4" POLYETHYLENE GAS LINE INCL TRENCH 125 lf NEW POST BOLLARDS 2 ea NEW CONCRETE ADA CAMPSITE #2 AMENITY PAD 41 sy
NEW 4" CONCRETE SIDEWALK 240 sy NEW CONCRETE ADA PARKING 50 sy NEW CONCRETE HOT TUB PAD 55 sy NEW CONCRETE CABANA PAD 16 sy NEW CONCRETE KIOSK PAD 4 sy NEW 2" PVC WATER PIPE in trench 4,640 lf 3.5' x 5' STEEL PLATE SCUPPER 1 ea
Mobilization/Site Preparation
Demolition
Site Road Stabilization; Additive # 1
SWPPP (Erosion control)
Amenity Areas Stabilization
FEE Station & Pond
Camp Host Site
Hot Tub Area
Bureau of Land Management Hot Well Dunes Recreation Area
Estimated Quantities
ADDENDUM 01 CHANGES 9/19/2025
Estimated Quantities are for information purposes only, contractor is responsible for determining quantities.
Tree removal large trees avg~ 40' high; remove root/stump 84 EA Equipment/sub mobilization 1 LS Removal off site 1 LS Invasive plant removal at pond area 6,665 SF Pond rehabilitation 6,665 SF Nature trail compacted dg surfacing 4,252 SF Nature trail rehabilitation (tree limbing) 893 LF 17"x11" CMP Culvert incl trench/bacfill/rip rap ; 15 lf 1 LS Water harvesting basins 400 CF Demo and Replace Split rail fence Additive #3 403 LF Barbed wire perimeter fence repairs 21,700 LF 16' x 50" Standard Metal Gates as LP501 2 EA 3'h Rail fence 1,579 LF Vehicular Access Gate, details 5 to 8/ LP502 1 EA 18" high parking guards 21 EA Maze Gate 1 EA 42"h Decorative metal view fence 30 LF 6' Decorative metal fence 120 LF 6'h X 4'w Decorative metal gate with self closing ADA compliant hardware 1 LS 6'h X 4'w Decorative metal gate with self closing hardware 1 LS Decomposed granite surfacing 4,483 SF Shrubs 54 EA Trees 8 EA Hydroseed Additive #4 119,000 SF Lined drainage swale (3" gravel and clay mat) 811 LF 16"x6" wide Cocrete Headwall at drain outlet 1 EA 4" HDPE drainage pipe 125 LF 4" Perforated HDPE drainage pipe 100 LF 4" Schedule 80 Ball valve in access box 2 EA Pop out drain emitter 6 EA Schedule 40 pvc sleeve 12 LF Drainage Box for tub 2 EA
NEW SPAS 1 ls NEW SINGLE RESTROOM STRUCTURE 1 ea NEW DOUBLE RESTROOM STRUCTURE 1 ea KIOSKS 3 ea INTERPRETIVE SIGNS 2 ea
HANDICAP PARKING SIGNS 3 EA
NEW FEE PAYMENT STATION 1 ea NEW CAMP GRILL 19 ea NEW CAMP FIRE RING 14 ea NEW 12'X12' SHADE STRUCTURE 16 ea
NEW PICNIC TABLE 18 EA
NEW CONCRETE BENCH w/backrest 2 EA
NEW 16'X16' SHADE STRUCTURE 1 EA
PREFABRICATED STORAGE BUILDING 1 EA
NEW TRASH CANS 23 EA
PANEL KIOSK-ROCKART 03-431 2 EA
CAMP HOST SIGN; ROCKART 1 EA
NEW SIGNS -CAMPSITE 13 EA
NEW ADA SIGN -CAMPSITE 2 1 EA
Landscaping
Furnishings
Tree removal Additive #2
Bureau of Land Management Hot Well Dunes Recreation Area
Estimated Quantities
Estimated Quantities are for information purposes only, contractor is responsible for determining quantities.
Fuel line, double contained from propane tank to generator U/G incl Allowance to fill propane tank 1 ls Conduit, PVC, U/G, 1 1/4" 25 lf Trench & backfill 20 lf Copper wire, 600V, XHHW, #2 75 lf Bare copper ground, #8 625 lf PVC, 1" w/control cable, direct bury 25 lf Grounding 1 ls Conduit, PVC, U/G, 1 1/4" 25 lf Tag & label 1 ls Conduit, PVC, U/G, 1" 300 lf Conduit, PVC, U/G, 1 1/4" 60 lf Trench & backfill 50 lf Copper wire, 600V, XHHW, #6 210 lf Bare copper ground, #10 370 lf LED strip light fixture, weatherproof, tamper proof 2 ea Motion detector switch, weatherproof enclosure, keyed, tamper proof 1 ea Conduit, rigid steel, 3/4" 60 lf Copper wire, 600V, XHHW, #12 120 lf Bare copper ground, #12; insulated 60 lf Duplex receptacle, weatherproof 1 ea Duplex receptacle, 2 ea Conduit, rigid steel, 3/4" 50 lf Copper wire, 600V, XHHW, #12 165 lf Bare copper ground, #12 55 lf Mechanical connnections: Hot tubs (assumed disconnects) 2 ea Conduit, PVC, U/G, 1 1/4" 200 lf Trench & backfill 200 lf Copper wire, 600V, XHHW, #12 630 lf Bare copper ground, #12 210 lf Conduit, rigid steel, 3/4" 25 lf Copper wire, 600V, XHHW, #12 60 lf Bare copper ground, #12 30 lf
Panelboard CH, 120/240V, 100A, MCB NEMA 1R enclosure 1 ea Generator, 120/240V, 12kW, propane including fuel tank 1 ea Generator annunciator panel, weatherproof enclosure 1 ea NEMA 3R 100A/2P, 250V MTS 1 ea NEMA3R 100A/2P 250V Emergency shut-off, weatherproof lockable 1 ea 50A/2P NEMA 3R RV Power pedestal for panelboard 1 ea Solar panels 12 ea Solar shade structure 1 ls DC MNDC-175 PlusDc Breaker box 6 ea Combiner, Midnite Solar MNPV12 mtd 1 ea Victron 48v DC 5000VA Multi Plus Inverter 2 ea Midnite Solar MPPT 250/70 TR VE 2 ea Lithium battery bank 20KWH 1 ea Solar light with battery for host lighting 1 ea Wasserman style 4wdwp5-55 115v .5 gpm; 125'head 1 ea Bard one ton heating & cooling system 1 ea ST-1_West-Mark 2024 potable water tank 275 gallons 1 ea
Electrical scope as ES101, ES102 & E-601
Solar - Host Site
Bureau of Land Management Hot Well Dunes Recreation Area
Estimated Quantities
Estimated Quantities are for information purposes only, contractor is responsible for determining quantities.
Solar panels 12 ea Combiner, 3 circuits Midnite Solar MNPV-12 1 ea Solar shade structure 1 ls SUNGOLDPOWER SPH6548P 6.5KW OFF-GRID INVERTER RATED 55C 1 ea 8"x8"x6" NEMA3R junction box with mounting 3 ea Trojan solar saes 12 105 12V battery 4 ea 250V AC NEMA 3R lockable fused disconnect 3 ea P-01_New Well Pump - RPS Pro Series 3000 sunmersiable 3HP w/ RPS40PRO control 1 ea Piping & Plumbing 1 ls Christy fl36t utility box 17" x 30" with bolt down lid. 2 ea Relocate existing pump head, control valves 1 ls Connections incl Piping & Plumbing incl with Hot tub cost incl Allowance for valves and core drills 1 ls
Solar panels 6 ea Solar shade structure 1 ls 8"x8"x6" NEMA3R junction box with mounting 2 ea 8x8x6 NEMA 3R Junction box 5 ea Conduit, rigid steel, 1 1/4" 20 lf Conduit, rigid steel, 3/4" 350 lf Copper wire, 600V, XHHW, #3 75 lf Bare copper ground, #8' insulated 25 lf Copper wire, 600V, XHHW, #12 2,850 lf Bare copper ground, #12; insulated 1,425 lf Terminations - PV (18 panels total) 130 ea Terminations - equipment 130 ea Grounding 1 ls Testing & miscellaneous accesorries 1 ls
Equipment Hot tub - allowance 2 ea Non-freeze ground hydrant 2 ea shutoff valve 2 ea 2" pipe, U/G 450 lf Trench & backfill 450 lf Combination Air/Vacuum valve, APCO AVC model 143C 1 ea
Solar - Pump House
Solar - Kiosk at Hot Tubs
Bureau of Land Management Hot Well Dunes Recreation Area
Estimated Quantities
Estimated Quantities are for information purposes only, contractor is responsible for determining quantities.
Supervision/PM 1 ls Job site Facilities 1 ls
Testing & inspections 1 ls Cleaning (on-going) 1 ls Temp Fencing/Security/Storage/Signage 1 ls Vehicles/ Equipment 1 ls Safety/first aid 1 ls
Additive #1 Road Stabilization Additive #2 Tree Removal Additive #3 Split Rail Fence Additive #4 Hydroseed
Job Personnel
Miscellaneous
General Requirements; Supervision/Job site facilities etc
Bureau of Land Management Hot Well Dunes Recreation Area Estimated Quantities
Estimated Quantities are for information purposes only, contractor is responsible for determining quantities.
| 02 HWD Bid Schedule Addendum 01_08 26 2025 |
| 02 HWD Bid Schedule Addendum 01 - 09 19 2025 |
| Blank Page |
File details come from the government source that posted it. Updated .