AMENDMENT 0001

RFQ 1333ND21QNB610162

Title: Manufacturing, Installation, and Testing of Double -Walled Warm Deuterium

QUESTION 1: Section #5.1 and #5.2 refer to the inner Deuterium transfer line as 1-1/4” SCH 40 pipe, drawing # 002-3073 indicates 1” SCH 40 pipe. Which is correct?

RESPONSE 1: Drawing 002-3073 should show the pipe as 1-1/4” pipe, it is now shown incorrectly as 1” pipe.

Drawing 002-2858 does not show pipe size, it should show pipe size as `-1/4” pipe.

QUESTION 2: Can you please provide size of Deuterium Charging Line drawing #002-2858.

RESPONSE 2: Drawing 002-2858 does not show pipe size, it should show pipe size as `-1/4” pipe.

QUESTION 3: Section 5.4, page 19, “…non-destructive tests (NDT) of welds are detailed in section 6.4 of this specification.” I see no section 6.4, section 6.3.3, however, does provide information for additional testing. Is this a typo?

UPDATED DRAWINGS ARE ATTACHED TO THIS POST AS A PART OF THIS AMENDMENT

All other terms and conditions remain unchanged and in full force and effect.

End of Amendment