This document provides a known or suspected asbestos-containing materials (ACM) list for the NOAA Ship Fairweather, as well as details for solicitation number 1305M221QNMAN0114. The ACM list identifies the location and quantity of various insulation, gaskets, and other materials throughout the ship that are known or suspected to contain asbestos. Several items are noted as having been removed. The solicitation is for drydocking and repair services for the NOAA Ship Fairweather. Interested parties are directed to contact the named Contracting Specialist and Contracting Officer by email to request reference documents and drawings associated with the solicitation due to file size limitations. The solicitation identifies the Department of Commerce National Oceanic and Atmospheric Administration as the issuing agency.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Last Updated May 2021
Known/Suspected Asbestos List
NOAA Ship Fairweather recognizes the potential presence of asbestos in the following locations –
White insulation inside braided wiring with black rubber and mastic throughout ship in cable guides
Overhead canvas and asphalt-wrapped fiberglass duct insulation E-04-001 Passageway E-05-001 Passageway
Woven cloth pipe collar (pipe wraps under hangars) A-02-001 LODAR room (5) B-02-003 Bow thruster room (2) B-03 Cofferdam below port potable water tank (2) B-05 Reefer Flat/Engineering Stores overhead (4) B-07 Shaft alley side of watertight door (30) B/C-05 Ladderwell (6)
| B/C-06-001 Engine Room (18) |
| C-03 passageway above stateroom 102 (1) |
| C-05-103 Stateroom (2) |
C-05-107 Stateroom (3) C-05-001 Computer room (7) C-02-001 Lower 02 Stores (4) D-02 anchor windlass HPU (6) D-04-103 Plot 2 (1) D-05-105 Elevator machinery room (1) E-06-102 Emergency Generator Room (24)
Bulkhead penetrations C-06-002 Stairs Down to Engine Control (1) (encapsulated 11/22/19) D-06-103 Aft mess deck (1) E/D-05 (port) Ladderwell (1) F-04-002 (FWD) Plot 1 (1)
Roving material; sound proofing, mounted cloth strips under perforated metal D-03-001 Fanroom 2 D-08-102 Fanroom 3
Residual steam pipe deck/bulkhead penetrations B-02-003 Bow Thruster room (2) C-02-001 02 Stores (2) D-05-110 Athwartship to port breezeway (2) D-05-107 Athwartship to starboard breezeway (2) E-05-002 Chiefs’ office passageway port (2) E-05-002 Chiefs’ office passageway starboard (2) E-06-102 Emergency Generator Room (2) F-03-001 (6 presumed behind forward bulkhead curtains)
Exhaust gasket E-06-001 Fiddley C-06 Upper Engine Room E-06-102 Emergency Generator Room
Engine vibration mount box cloths B-06 Engine Room (48; 4 cloth strips per box, 6 boxes per engine)
Powdery substance between bulkhead and paint (no longer suspected ACM, but never tested; likely Bondo)
| E-06 Boat Shop |
| E-06 Weld Shop |
Consult the Known/Suspected ACM Table and associated reports located in N:\Command\Collateral Duties\Environmental Compliance\Asbestos and the AMP tab 3.
Removed Asbestos List
Woven cloth pipe collar (pipe wraps under hangars) B-03 Cofferdam below port potable water tank (1) (removed 5/6/21)
| B-04-103 Butcher Shop (2) (removed 11/17/19) |
| B-06 Engine room overhead above fuel oil purifier (1) (removed 5/11/21) |
| C-04-105 Stateroom (1) (removed 4/29/19) |
| C-05-103 Stateroom (1) (removed 4/29/19) |
| C-06-002 Ladderwell to Engine Control (1) (removed 11/22/19) |
Pipe insulation C-06-002 Ladderwell to Engine Control (1) (removed 11/22/19) C-06-002 Engine Control overhead (removed 11/22/19)